HomeMy WebLinkAboutR-397010r i I I I I / I I I I / i I I / I I I t I I t I V UTILITY CONFLICT NOTE II I .. \ 6" THK PERMEABLE CONC. r� THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND , EXG BUILDING O --- I ° STORAGE RESERVOIR (CLEAN ROCK, MIN 40 /° VOIDS) DOWNSPOUT TIGHTLINE CONNECTION C5) DEPTH OF ALL EXISTING UTILITIES, WHETHER SHOWN ON THESE PLANS OR NOT, BY \ DEPTH AS NECESSARY TO REPLACE EXG C'7 POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR I d- I I COMPACTED SOILS 18" MIN, (TO BE EVALUATED BY WEARING COURSE SLOPE PER PLAN TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800424-5555 AND I ...: r-- \ GEOTECHNICAL ENGINEER) THEN POTHOLING ALL EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO ( w \ DOWNSLOPE END OF PERMEABLE PAVEMENT 0 PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS I CONC BAND BETWEEN PAVEMENTS PER COR I \ SUBSURFACE WATER STORAGE AREA ADJACENT HARDSCAPE SHOWN ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. IF I STD PLAN 261.00 \ 1" W CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT AP CONSULTING ENGINEERS ( E-- PROBLEMS PRIOR T PROCEEDING WITH CONSTRUCTION. PLLC TO RESOLVE ALL 0 S 0 C I _ AS BUILT EDGE OF PERMEABLE PAVEMENT o \ I 1 0 \ O \ Z \ 434.4 MATCH EXG GRADE \ PVC UNDER PAVEMENT - -- -_- TO 8E SOLID WALL, -Rim_-40� _j 1 PERFORATED, & WRAP R I ' 35.14 IN GEOTEXTILE FABRIC (TYP) SURFACED MACH URFASLOPE " IMPERMEABLE CHECK DAM - 6" 0 SOLID PVC rr CONC BAND AT US PER (CONC OR EQUIVALENT) 6" SAND FOR TREATMENT DAM SLOTTED UNDERDRAIN O = AS -BUILT NOTE \ COR STD PLAN 261.00 USE SPLASHBLOCKS TO I DIRECT FLOWS FROM DS TO o \ 1 6" MIN COMPACTED DEPTH NON -WOVEN GEOTEXTILE ON BOTTOM & SAND (30% POROSITY) PER (CONC) ) (%) ' TRACT \ o PERMEABLE PAVEMENT `� SIDES OF FREE -DRAINING BASE. SPECIFIC THE SPECIFICATIONS THAT GEOTEXTILE PER GEOTECHNICAL ENGINEERS 1. AS -BUILT INFORMATION ON THESE DRAWINGS IS BASED ON 2117.16 SQ FT---_ \ I ARE PART OF THIS DETAIL. XG B RECOMMENDATION. OVERLAP ADJACENT Cn INFORMATION PROVIDED TO APCE BY TOLIMA ENGINEERS & 0.05 ACRES \_- - STRIPS OF FABRIC AT LEAST 24" _ >_ LAND SURVEYORS AND ANYTHING NOT SHOWN ON THESE � _ DESIGN SPECIFICATIONS: J PLANS AS HAVING BEEN CONSTRUCTED DIFFERENTLY FROM Lnr -_° _--_'_-0____ __ __� ---------- WHATWAS SHOWN ON THE APPROVED CONSTRUCTION _---a ------------------------ DS ----- i DRAIN #3 1. A MINIMUM OF 6 INCHES OF FREE -DRAINING SAND OR GRAVEL BASE IS REQUIRED UNDER THE POROUS DRAWINGS IS UNDERSTOOD BY APCE TO HAVE BEEN BUILT \ I { STA 19,89�4859�-10+80.83,100.81 L CONCRETE SURFACE. _I PER THE APPROVED DESIGN PLANS. O - 51 LF 4" 0 PVC PIPE I I _ _- -__ -, _ � RIM = 434.3a- 435.40 2, THE FREE -DRAINING BASE SHALL HAVE LESS THAN 5%FINES (MATERIAL PASSING THE #200 SIEVE) 2. OTHER THAN AS SHOWN AS -BUILT CHANGES TO SURFACE I -ERVIOUS PAVEMENT I ' -- -- - - , I - _ I �2.0 IE(N) = 432.2 BASED ON THE FRACTION PASSING THE #4 SIEVE. ELEVATIONS ARE NOT REFLECTED IN THIS PLAN. CD DTL 11C3 _ - - ___ __ __ ; IE(S)= 434-;z9;2" PJ 431.84 3. THE POROUS PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 10 INCHES PER HOUR IMMEDIATELY AFTER THE PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY 1 00 ( , , 66.4 p gg% (TYp) FOR AT LEAST 10 MINUTES. COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO 00 I CONC BAND AT LIS PER COR STD CONNECT DS ON REAR OF I 69 LF 12" 0 PVC PVC Pipe @ -14% CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE O O ( PLAN 261.00 { ��f I BUILDING TO CONVEY STORMWATER TO i BUCKET TEST IN WHICH 5 GALLONS OF WATER ARE POURED ONTO THE PAVEMENT SURFACE ALL AT ONCE FROM A 5-GALLON BUCKET. IF NOTHING BUT A SCANT AMOUNT OF WATER PUDDLES OR RUNS TABLE 1 SAND MEDIUM SPECIFICATION US SIEVE NUMBER PERCENT PASSING 4 95-100 8 70-100 16 40-90 30 25-75 50 2-25 100 <4 200 <2 �\ \ 11,8j3% LOT 2 PERMEABLE PAVEMENT I 1 OFF THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF W ~ l ' 5090.08 SQ FT I I ABSORPTION. IF THIS TEST IS NOT CONCLUSIVE, THEN A 6-INCH RING SEALED AT THE BASE TO THE m 33.00 44 1 0.12 ACRES 5.2' \ PAVEMENT SURFACE SHALL BE USED TO MEASURE THE ACTUAL RATE OF ABSORPTION. ` y� 433.50 LOT 2 83' ` 1 PERMEABLE PAVEMENT z \ ' NEW 15 LF 4"0 PVC SDR-35 ' ' \ C3 NTS I UNDER SEPARATE PERMIT FF = 433.50 I \ WISOOS CREEK SWD \ W W RECONNECTJEXG HOUSETOINEW - - I I v A CROSSING TABLE - \ WATER SERVIC� LINE - \ I 433.50 j'� CHECK DAMS PER PERVIOUS PAVEMENT DTL 11C3 USE CT FLOWS FROM DS \j B NOTES: 6.4 FT SPACi �G BETWEEN DIMS 32 75 I � � DIRECT FLOWS FROM DS T0�_ PERMEABLE PAVEMENT 51 LF 4" 0 PVC PIPE , 1. CB PER COR STD DTL 200 UNLESS OTHERWISE INDICATED ON I \, THESE PLANS. EXG 8 LF 00 PVC . ��� = DSO-__-__�_ __ 2. CB INSTALLATION PER COR STD DTL 202 UNLESS OTHERWISE SIDE SEWER STUB --° -- - ------ INDICATED ON THESE PLANS. ) CONNECT NEW CONC BAND BEMI EEN PAVEMENTS �`' HOUSE TO NEW goo „ - - PER COR STD PLAN,'261.00 I WATER SERVICE LINE o 1 - CB # 3 �_ _ -- --- -- -- -- - s rk 16;81.70, 34.40L -- "' I TYPE , CB, FRAME & GRATE _ _- - 1 YARD DRAIN #1 STA 10+3.50, 32.90 NEW DOMESTIC WATER SERVICE CONNECTIONS AND METERS UNDER 'a- 431.57 RIM =-+3+.-;$ 433.33 RIM =�8� / SEPARATE PERMIT W! SOOS CREEK SWD I - " \ \ 42 .79 IE(S,12"0)= 428.82 (N) Ir`ur)436.42 12" 0 43 .18 -43Q 53 lz-aL -�-fi . 3 � NEW FH (S) Ir• 12 0 42 .83 \\ 1. EXCAVATE TO THE ELEVATION OF THE FREE -DRAINING SAND OR GRAVEL BASE. 2. PREVENT SEDIMENT AND RUNOFF FROM ENTERING BED DURING CONSTRUCTION. 3. COMPACT UPPER 12" OF EXISTING SUBGRADE SOIL TO ENSURE 90-92% STANDARD PROCTOR 4. AVOID OVER -COMPACTION BY RESTRICTING ACCESS TO THE AREA FOR MATERIAL STOCKPILING & HEAVY CONSTRUCTION VEHICLES 5. FINAL GRADING SHOULD BE COMPLETED BY MACHINERY OPERATING ON A PRELIMINARY SUBGRADE THAT IS AT r LEAST 12 INCHES HIGHER THAN FINAL GRADE OR STRUCTURES TO DISTRIBUTE EQUIPMENT LOAD (E.G,, �? STEEL PLATES OR AGGREGATE BASE MATERIAL). FINAL C'7 EXCAVATION THEN PROCEEDS AS MACHINERY IS PULLING 0 BACK AND TRAVELING ON PRELIMINARY GRADE AS FINAL O GRADE IS EXCAVATED. 6. TO PREVENT COMPACTION WHEN INSTALLING THE AGGREGATE BASE, THE FOLLOWING STEPS U (BACK -DUMPING) SHOULD BE FOLLOWED: 1) THE AGGREGATE BASE IS DUMPED ONTO THE SUBGRADE FROM THE EDGE OF THE INSTALLATION AND AGGREGATE IS THEN PUSHED OUT ONTO THE SUBGRADE; 2) TRUCKS THEN DUMP SUBSEQUENT LOADS FROM ON TOP OF THE AGGREGATE BASE AS THE INSTALLATION PROGRESSES. 7. AVOID SUBGRADE PREPARATION DURING WET PERIODS (SOIL COMPACTION INCREASES SIGNIFICANTLY IF SOIL IS WET). 8. IF MACHINERY MUST ACCESS THE FINAL GRADE, LIMIT THE ACCESS TO A SPECIFIC TRAVEL WAY THAT CAN BE TILLED BEFORE APPLICATION OF THE BASE AGGREGATE OR PLACE HEAVY STEEL PLATES ON SUBGRADE AND LIMIT TRAFFIC TO THE PROTECTIVE COVER. (Q NOTE: ALLOWING HEAVY MACHINERY ON PERMEABLE I O PAVING SUBGRADES DURING WET OR SATURATED CO CONDITIONS WILL RESULT IN DEEP COMPACTION (OFTEN 3 0 FEET) AND CANNOT BE COMPENSATED FOR BY SHALLOW C) TILLING OR RIPPING SOIL (BALOUSEK, 2003). 0 r SAND SPECIFICATION: Q THE SAND MUST CONSIST OF A MEDIUM SAND MEETING THE SIZE GRADATION (BY WEIGHT) GIVEN IN TABLE 1. THE CONTRACTOR MUST OBTAIN A GRAIN SIZE ANALYSIS FROM THE SUPPLIER TO CERTIFY THAT THE SAND MEETS THE NO. 100 AND NO. 200 SIEVE REQUIREMENTS. (NOTE: STANDARD BACKFILL FOR SAND DRAINS, WA. STD. SPEC. 9-03.13, DOES NOT MEET THIS SPECIFICATION AND DO NOT USE SPEC 9-03.13 FOR SAND FILTERS.) Crossing Pipe ID Pipe Material Size Outside Invert Pipe ID Pipe Material Size Outside Invert Separation Number Diameter (in.) Elevation (ft.) Diameter (in.) Elevation (ft.) (in) (in) PVC SDR-35 PVC SDR-35 S1 STORM (4"-36") 12,0000 12.5000 427.55 SEWER (4"-36") 6.0000 6.2750 420.41 6.61 PVC SDR-35 PVC SDR-35 S2 STORM (4"-36") 8.0000 8.4000 428.14 SEWER (4"-36") 6,0000 6.2750 418.77 8.84 PVC SDR-35 DI Class 52 W1 STORM (4"-36") 12.0000 12.5000 426.43 WATER (4"-54") 6.0000 6.9000 424.36 1.52 PVC SDR-35 Concrete W2 STORM (4"-36") 12.0000 12.5000 426.69 WATER (6"-72") 12.0000 17,0000 423.25 2.21 _ 431.59 46 E 85.00 12" AC (REF) 588 \ ® - d - - a .a - O4 n - ' _ _-_EXG CORRUGATED HOPE PIPE 1 43�,35 - a a a a a a 'o a 23.4 1.84% 21.9 a a F 12"PVC Pipe @ 2.6694TOHP L 12SDR-35 - W- -UGP .UGP PA =aa-UGP -W_IE_#32 432.28 -W r 1 \ �.� 1 r OH 6' (REF) -- - /�� -- W- - -W ' OHP O P OHP OHPOHP ' _ OHP - OHP - - - - -- \ - - - u> ° 1.2 \ 12"SDR-35 @ _ -- IE = 427.77 , u a I Z 1 30.2-2R LF 16" DIP @ / - 1.95% / CONTRACTOR T - -- 1 1.5' VERTICAL SEPARATION j CON IMCTOR TO ENSURE L5' VERTICAL SEPARATION 44-LF 12" SDR-35 @ / I BETWEEN STORM & WATER 1 00/ i 9+60 cn / BETWEEN STORM & WATER i' 16.5 16.85% 88 04 46 SE164H E 260. � S T. 11+19 r -�- - S EXG CB - - - t S - S - - - S EXG SSMH STA 10+01.20,17,15L CB # 1 j - - S - - - S - S_' . - - S - - - S - i _ S - -- - - -- TYPE 1 CB, FRAME & GRATE \ - S - - S - -- S - - S _ STA 9+63.26, 697R � RIM = 43Q41 � -S - - _S_ -- RIM = 428.75 IE(N) = 425.56 6" 0 PVC STAq 896.89, q 2-99E 10+7.65,13.56L (FC) TYPE 1 CB; FRAME & GRATE \ INV(E) = 415.1210" PVC IE(W) = 426.17 CORRUGATED HDPE PIPE RIM = 468.29- 430.48 \ STA -46+83 -1�88b 10+77.93,12.08L (FC) \. (RAISE RIM TO MATCH NEW GRADE) IE(W,16"0)fiP@"428.36 1 RIM m#3333.433.25, � � - - IE(W,12"0) � \ \ IE(E" - - - - - -IEf NWF 12"9j - 4P9.59 IE*\ 430.4 . --- - - - - - IE(NE,12 0) = 429.50 - - C'7 C'7 C) 0 U ti C) (V° ] to T z l� 00 WZ X o ww m W a Z r J M V L W O � _j LO ti Uw0 U w rn 0 v w U CL d D- - _D -`-R- 397010 -' D - - - p - - -- p -D - -- -D - - -D -D IN COMPLIANCE WITH CITY OF RENTON STANDARDS W E �l GRADING, DRAINAGE, & UTILITIES PLAN C� 1 =10' s 1 AS -BUILT AEP 06/28/2019 SURVEYED: SCALE: HORIZORNnTAL: N D 1983/11991 • DESIGNE KL SCALE CITY 0 F LALLY'S SHORT PLAT DRAWN: R E N T O N K L ONE EIINCH� • CHECKED: I AT FULL scuE I DATUM Planning/Building/Public Works Dept. GRADING, DRAINAGE & NO. REVISION BY DATE APPR -- IF NOT ONE INCH UTILITIES PLAN APPROVED: SCALE ACCORDINGLY Q J CL F- Ir TO DATE 08/03/2017 (n FlEwBwK: BOOK (� PACE' PAGE DRAWING NO: C 3 i SHEET: 3 OF: 7