HomeMy WebLinkAboutzW-4085SetLJ Z J T C) TO v , T N WATER GENERAL NOTES 1. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON 13. PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY. PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A 14. FIRE HYDRANTS SHALL BE INSTALLED PER CITY OF RENTON STANDARD DETAIL FOR FIRE HYDRANTS, LATEST REVISION. SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AT (425) 430-7301. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ANY WORK IN THE RIGHT OF WAY. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATES CALL 48-HOUR LOCATORS 800-424-5555. 4. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE SUBMITTED AT THE PRE -CONSTRUCTION MEETING. 5. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 6. ALL WATERMAIN PIPE IS TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO AWWA C110 AND C111 OR LATEST REVISION, THICKNESS CLASS 52. CEMENT MORTAR LINING AND SEAL COATING SHALL CONFORM TO AWWA C104 OR LATEST REVISION. PIPE JOINTS TO BE PUSH -ON OR MECHANICAL JOINT. BEDDING TO BE CLASS C. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE POLYETHYLENE WRAPPED PER ANSI/AWWA C105/A21.5-93 STANDARDS. 7. CAST IRON AND DUCTILE IRON FITTINGS SHALL BE CEMENT LINED, PRESSURE RATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH ANSI/AWWA C110/A21.10-87. CEMENT LINING SHALL BE IN ACCORDANCE WITH ANSI/AWWA C104/421/4-90. IF FITTINGS ARE 3 TO 12 INCHES IN DIAMETER AND HAVE MECHANICAL JOINTS, THE FITTINGS SHALL IN ACCORDANCE WITH EITHER ANSI/AWWA C110-A21.10-87 OR ANSI/AWWA C153/A21.53-94. THREE (3) INCH TO 12 INCH DIAMETER FITTINGS, WHICH HAVE MECHANICAL JOINTS AND/OR FLANGED JOINTS, SHALL BE IN ACCORDANCE WITH ANSI/AWWA C110/A21.10.87 OR A COMBINATION OF ANSI/AWWA C110/A21.10.87 AND ANSI/AWWA C153/A21.53-94 SUCH THAT THE PORTION OF THE FITTING WITH A MECHANICAL JOINT(S) MAY BE WITH ANSI/AWWA C153/A21.53-94 AND THAT PORTION OF THE FITTING WITH FLANGED JOINTS) SHALL BE IN ACCORDANCE WITH AWWA C110/A21.10-87. ACCEPTANCE TESTING IN ACCORDANCE WITH SECTION 53.53 OF ANSI/AWWA SECTION 10-4.3 OF ANSI/AWWA C110/A21.10-87 SHALL BE OBTAINED BY THE CONTRACTOR AND TRANSMITTED TO THE OWNER. 8. GATE VALVES SHALL BE IRON BODY, BRONZED -MOUNTED, DOUBLE DISC WITH BRONZE WEDGING DEVICE AND 0-RING STUFFING BOX (AWWA C500) OR OF RESILIENT SEATED TYPE (AWWA C509). VALVES SHALL BE DESIGNED FOR A MINIMUM WATER OPERATING PRESSURE OF 200 PSI. GATE VALVES SHALL BE CLOW LIST 14, MUELLER COMPANY NO. A2380 OR M & H. 9. FIRE HYDRANTS SHALL BE COREY TYPE (OPENING WITH THE PRESSURE) OR COMPRESSION TYPE (OPENING AGAINST PRESSURE) CONFORMING TO AWWA C-502-85 WITH A 6 INCH MECHANICAL JOINT INLET AND A MAIN VALVE OPENING (M.V.O.) OF 5-1/4 INCH, TWO 2-1/2 INCH HOSE NOZZLES WITH NATIONAL STANDARD THREADS 7-1/2 THREADS PER INCH AND ONE 4 INCH PUMPER NOZZLE WITH THE NEW SEATTLE PATTERN 6 THREADS PER INCH, 60 DEGREES V. THREADS: OUTSIDE DIAMETER OF MALE THREAD 4.875 AND ROOT DIAMETER 4.6263. HYDRANTS SHALL HAVE A 1-1/4 INCH PENTAGON OPERATING NUT OPENED BY TURNING COUNTER CLOCKWISE (LEFT). 10. THE TWO 2-1/2 INCH HOSE NOZZLES SHALL BE FITTED WITH CAST IRON THREADED CAPS WITH OPERATING NUT OF THE SAME DESIGN AND PROPORTIONS AS THE HYDRANT STEM NUT. CAPS SHALL BE FITTED WITH SUITABLE NEOPRENE GASKETS FOR POSITIVE WATER TIGHTNESS UNDER TEST PRESSURES. 11. THE 4 INCH PUMPER NOZZLE SHALL BE FITTED WITH A STORZ ADAPTER, 4 INCH SEATTLE THREAD X 5 INCH STORZ. STORZ ADAPTER SHALL BE FORGED AND/OR EXTRUDED 6061-T6 ALUMINUM ALLOY, HARDCOAT ANODIZED. THREADED END PORTION SHALL HAVE NO LUGS AND TWO SET SCREWS 180 DEGREES APART. STORZ FACE TO BE METAL, NO GASKET TO WEATHER. STORZ CAP TO HAVE SYNTHETIC MOLDED RUBBER GASKET, AND SHALL BE ATTACHED TO HYDRANT ADAPTER WITH 1/8 INCH, COATED, STAINLESS STEEL, AIRCRAFT CABLE. 12. FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS OF PAINT. PRESERVATIVE PAINT NUMBER 43- 655 SAFETY YELLOW OR APPROVED EQUAL. cow*ote r r a ENGINEERING PLLC 321 3rd Ave South, Suite 406 Seattle, Washington 98104 ph 206.596.7115 coterraengineering.com 35163, SIGNAL' 15. ALL WATERMAINS 10 INCHES AND SMALLER TO MAINTAIN A MINIMUM COVER OF 36 INCHES BELOW FINISH GRADE. ALL WATERMAIN 12 INCHES AND LARGER SHALL BE AT A MINIMUM OF 48 INCHES BELOW FINISH GRADE. WHERE UTILITY CONFLICTS OCCUR, WATERMAINS ARE TO BE LOWERED TO CLEAR. 16. ALL WATERMAINS 6 INCHES AND LARGER IN DIAMETER SHALL BE CLEANED WITH PIPE CLEANING "PIGS" PRIOR TO DISINFECTION. THE "POLY PIGS" SHALL BE GIRARD INDUSTRIES AQUA SWAB -AS OR APPROVED EQUAL, 2 LB/CU. FT. DENSITY FOAM WITH 90A DUROMETER URETHANE RUBBER COATING ON THE REAR OF "PIG" ONLY. 17. "PIGS" SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END. THE CONTRACTOR WILL PERFORM THE CLEANING OPERATION. 18. ALL WATERMAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH DEPARTMENT. ALL PRESSURE TESTING SHALL BE DONE IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY OF RENTON. THE QUANTITY OF WATER LOST FROM THE MAIN SHALL NOT EXCEED THE NUMBER OF GALLONS PER HOUR AS LISTED IN CITY OF RENTON STANDARD PLANS & SPECIFICATIONS 7-11.3(11). THE LOSS IN PRESSURE SHALL NOT EXCEED 5 PSI DURING THE 2 HOUR TEST PERIOD. 19. ALL WATERMAINS AND SERVICES SHALL BE DISINFECTED BY THE INJECTION OF A 50 PPM (MINIMUM CONCENTRATION) CHLORINE/WATER SOLUTION. DRY CALCIUM HYPOCHLORITE SHALL NOT BE PLACED IN THE PIPE AS LAID. CHLORINE SHALL BE METERED/INJECTED IN ACCORDANCE WITH SECTION 7- 11.3(12)E OR 7-11.3(12)F OF THE STANDARD SPECIFICATIONS REFERENCED ABOVE. 20. A PRE -CONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A MINIMUM OF FIVE (5) WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. 21. TWENTY-FOUR (24) HOURS NOTICE WILL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. 22. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. 23. INSTALLATION OF CORPORATE STOPS, WATER SERVICES, LINES AND METERS SHALL NOT BE DONE UNTIL ALL SERVICE AGREEMENTS, METER APPLICATIONS, CONSTRUCTION PERMITS, AND PAYMENT OF FEES HAVE BEEN MADE TO THE CITY OF RENTON. 24. ALL CONNECTION TO EXISTING MAINS IS TO BE ACCOMPLISHED BY THE CITY OF RENTON, EXCEPT WET TAPS, WHICH MAY BE MADE BY APPROVED WET TAP CONTRACTORS WITH PRIOR APPROVAL FROM THE PUBLIC WORKS DEPARTMENT. ALL NECESSARY EXCAVATION AND MATERIALS ARE TO BE SUPPLIED BY THE CONTRACTOR AND BE ON -SITE PRIOR TO CITY NOTIFICATIONS. 25. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY DEVELOPMENT SERVICES TWENTY FOUR (24) HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR, AS WELL AS THE ENGINEERS, SHALL KEEP AS -BUILT DRAWINGS. 26. CONTRACTOR TO PROVIDE PLUGS AND TEMPORARY BLOW -OFF ASSEMBLIES FOR TESTING AND PURITY ACCEPTANCE PRIOR TO FINAL TIE-IN. 27. ALL JOINT RESTRAINT SYSTEMS (SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE AS MANUFACTURED BY THE STAR MANUFACTURING COMPANY OF COLUMBUS OHIO, OR EQUAL, APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT. 28. ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES. OIL MAT STREETS MAY BE SPADE CUT. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURB, GUTTERS, AND DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. 29. A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE DAY OF INITIAL EXCAVATION WITH A PERMANENT, SEALED PATCH TO BE PLACED, TO CITY OF RENTON POLICY, WITHIN 10 DAYS. CALL FOR SUBGRADE INSPECTION PRIOR TO PLACEMENT OF FINAL PATCH. 30. FOR CITY PROJECTS SUCH AS TELEMETRY CONDUIT, THE PVC PIPE USED SHALL BE ALL CHEMICAL PROCESS LINES SHALL BE SCHEDULE 80 PVC PIPE. SCHEDULE 40 IN UNIMPROVED AREAS AND SCHEDULE 80 PVC PIPE UNDER IMPROVED AREAS. CIVIL CONSTRUCTION PERMIT RESUBMITTAL INTAKE CIVIL CONSTRUCTION PERMIT RESUBMITTAL INTAKE CIVIL CONSTRUCTION PERMIT RESUBMITTAL INTAKE CIVIL CONSTRUCTION PERMIT RESUBMITTAL SCREEN CIVIL CONSTRUCTION PERMIT SUBMITTAL NO. I REVISION SURVEYED: _ I SCALE: -/ . ' / . -I I DESIGNED: MB 11/14/19 11 /8/19 DRAWN. MB ICHECKED: PA I BY I DATE I APPR I APPROVED: 1 "=20' HORIZO TAL NAD/983/1991 ONE INCH DATU M AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY CITY OF RENTON Planning/Building/Public Works Dept. W-408501 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Nathan Janders 01 /03/2020 WILLOWCREST TOWNHOMES EDMONDS AVE NE, RENTON, WA NOTES 7/29/19 PAGE: DRAWING N0: C1.1 3 00 T a J N T C) O O T 0- () w 75 0 Z 0 W W Ir >U 0 J .J N WATERLINE (G2)° CB RIM=310.58' IE 8" CN� E=308.58 W ° a III m I I m II _z 1 >- ay„ I S m �I N ° LL e A N RIM I IE 61 CNIC W= (m ° . I I A m 3 rn N A � ° � m I 4 w 3 SOI, H TYPE LU&I JBIOX wRE RI 1=307. IE -�8" C - 4.22 k IE 1 6' CNC LI04.97 --18' CIQC I €W4.22 OI I� m ° 41 v ° I SSMW-4 1 =3 5. 'n n� I'^"I� N 8' IE .8' w S=217. TELEPHONE m 1 GAME RISER STREET 'I 3 SIGN WATERLINE G2 v W(REF)-W(REF) W E) w In I 1 1 ° z 3 I TELEPHON ° VAUL " ~� POWER I 3 VAULT a W I 3 w II U-) I y „ L� d a �I CD W o N 'I w ° 1 II N CD I rn �W i II I 3 + o w N III 1 3 I I I ° w w I W -ENCE IORTH I ENCE ` w ;OUT � I a w ° WATERLINE ( (G2) I � I I W w S MH UP ° I 3. 8' II1 3 IE 118' CNC N-269. 8' 10+ 0 g IE� 6" CNG ! E=2 0. 8' i p �•- LUMI AIRE « w IE 1 CNO ! & BOX �1 I 3 I ° I I ti VINYL 3 C) N ENCE w I N u ° w �I 00 z o � I I 3° �'54"E 30 0'� On Of U I'm H ITYPE 1 THE NORTH LINE OF THE S1/2 OF THE W1/2 OF THE NW1/4 OF THE NW1/4 OF THE NW1/4 OF SEC 9, TWP 23N, RNG 5E, W.M. 1 +00 REFER TO SHEET C4.0 FOR STORM DRAINAGE INFORMATION. �1 CM Ad N 1" DOMESTIC WATER PN 092305-9061 �' O (a(TY DOUBLE CHECK RI 8c L LTD PTSHP ROOF ELEV. 20 0 20 0 VALVE ASSEMBLY =F ELEV. EXISTING BUILDING T POFALLBLDGS) I _ PARTIAL FOOTPRINT GATE . . 6" SS 2.0% &ERY SCALE: 1 " = 20' rr rii rir rii r It'L DATUM (� 88*56' 4"E 8. 7' _ NAVD 88 NDOW X 1 00 - WEL UN 1, CAP - 174.62' LEGEND ' - ( ( S L #43 618 co 2» Ci OSS s' p�e�� T co 2 - BLI FLA GE SFW / » 1. N C -f - - SANITARY SEWER MAIN 5• ° TEMP B OW-0 F �qR 6 S SERVICE, PO PIG STA ON P '� T ` 3.5 ELOW FF - - - - SANITARY SERVICE LINE TY BLDG C) APN 722780-1370 5 C R STD PLA 300. I PERRINE 0 CLEANOUT CONC BL CKING /• •.\ • 1" OM W LS REBAR 36A8 C5. 4 FIRE HY ANT •% SE R ICE (TYP 74 2'30 SANITARY SEWER MANHOLE 48" 1 2 SEE NOTE #11 THIS SHEET. C5. C5. T C5. P) .. : / OF CORNE BL A d�( PARK BENCH ri 'S5'49"E 145 6 ' x „ - - - WATER SERVICE LINE Cfl 5 1 " DOMESTIC WA ER _ _ O I - / a, - �/� (TYP.) - - 6 R TIE WgLL - WATER/FIRE MAIN O C SERVI E AND MET R AND OUBLE CHE K I I I / CHECK VALVE ULT x //HEATPUMP /, 6 O rrrrrrriirrr-r/nm VALVE SSEMBLY R �{ H WATER VALVE 0 COR ST PLAN 3 0.8 I i ,'� (TYP) SEE NOTE 14/ I r, C5. (TY OF BL G A) 00 r 4 07 IRR ATER SERVIC PURL W EI � / y » FIRE HYDRANT r M ER ND D UBLE CHECK - 90' HB J o FI VA VE A EMBL PER 1� L ' SE VICE / s c WATER METER 5 ST 40.8 / PO 80- 375 BEND C5. J RENTON A ORITY • I P� 11.25° EA LINE 0 w1/2 H I . COR STD LAN I I �,, F�Re THE F THE 22.5° BEND • C5. + V- W /4 SEC 9, co g 7 6»3 FIR4 I o 6" 2 B RJ CD 5E, W.M. I a S 0 Y OUND ,� 45° BEND 1-12" "TEE FLXFL J. SERVICE I I / 1" IRR. S RVICE 0 0�� P ° _E-i 90' BEND °' Tf� 16 TEE ( RJ f�MA \NC 0 ESTI IN ° 2-12" TE VALVES (FLxMJ) � I ( ° 1-6" GA E VALVE (FLxMJ) B OCKING E F W OCKING H C� �� N VID UBNE ECK �� °� IJ WATER CAP 2 J CONC. BE cK SEE SHEET C4. FOR ! ! I �� N G Q WATER MAIN PR FILE 1 I \`\ \ cB TY 1 I PER CO S 7 WATER COUPLING C5. " 45' �� ►I WATER REDUCERS (TYP) I FD SE N TE 1 RIM=339.4 ' �I 40. ( F a5 r F I , 98' I I I 14 FIRE SE OC IE .�v s _ a �LDG ) C5 L Isl WATER TEE `7 L� PIV (TYP p <0 CONC THRUST BLOCKING HORIZ FIRE HYDRANT J N ® o ° _ C5. m (fl C5. I I � if22.5' RJ NH SIG (P'2 3 - ° c\I (TYP) AP 09 "' FIRE DEPT CONNECTION 1 " W - 45R T SIN I � 6" 5° B POST INDICATOR VALVE C)LOCKI G RJ % � � � � 0 N 355'49"W 1 6. 6 SDCO '0 2" W - 22.5° HBj ! � ! NOTES - a, \Op �23 BLOCKII \ \ + SEE S EET C 2 . FO I A ITARY d ° ° .\ z 1 ' PUBLIC SANITARY ,..:.' - K V .. IE 8' PVC - N EWER SEMENT I A E SE f� IC POC BE �fF(P2 IE 8" =333 -41� 2 15' PU LIC M NTENAN SSM # gi PVC=33�.�`3' Q " -, Q E 6--, c w_ ACCES GRA EL PAT RIP- RM 7 / z ,�� iE \ S - OUT P3) 2" W A R OFF I W - W _ y N / - ` ASSE BL ( (P3) ° FIRE \ FO ND REBA (/ / LANE 0 ARKING i T M S #4 ON 12" W P C SS 12+00� OF C NER _ i 4'H CHAIN LINK FENCE � � � � TYPE 1 12" GV MJ) o RIM-MIALCT TQ EX 12" - x WATER MAIN r N8 55'42"W 9.52' - �- - - x 1-12" COUPLING SSMH - - x x - x C5. STING 12" NIPPLE GARAGE FOUND REBAR & �,45° HB MJ 23 APN 092305-9161 PARTIAL SSM LS #43612, 431 BLOCKING THE NORTH LINE OF THE SOUTH 75' FOOTPRINT ON SOU"APYE EX 2 OF THE S1/2 OF THE W1/2 OF THE HSIEH INVESTMENTS "'W OASREQUIRED. 1FIELD 8 NW1/4 OF THE NW1/4 OF THE NW1/4 SEE SHEET C4.2 FOR EXIST FOOT[ ROOF ELEV. [ POWEI METER' �\ aCARPOR,4 APN 722780-1385 j VISSER EXISTING HOUSE PARTIAL FOOTPRII wl TELEPHONE M OF SEC 9, TWP 23N, RNG 5E, W.M. PUBLIC SANITARY SEWER o1 LOCATE LINE AND a w ANHOLE $" S s FIRE �_ (REF W(REF)-}IN REF R 5 MAIN PROFILE 1 (TYP) GRADE PRIOR TO �I " I - ONNEC 8" SS MAIN � CONSTRUCTION HYDRANT 3 MPk� AILBOX, STRE SIGN SIGNAL w-W(REF= w i SEE PR EET C4.2 FOR RIM AND IE (TYP) TELEPHONE RISER z 1 ml SIGNAL JBOX 3 N w N _ _ S88°55'42"E 319.70' N I � - - - - - - S88°55'42"E 144.31' co erra ENGINEERING PLLC 321 3rd Ave South, Suite 406 Seattle, Washington 98104 ph 206.596.7115 coterraengineering.com CIVIL CONSTRUCTION PERMIT RESUBMITTAL INTAKE CIVIL CONSTRUCTION PERMIT RESUBMITTAL INTAKE CIVIL CONSTRUCTION PERMIT RESUBMITTAL INTAKE CIVIL CONSTRUCTION PERMIT RESUBMITTAL SCREEN CIVIL CONSTRUCTION PERMIT SUBMITTAL NO. I REVISION 1 /2/20 SURVEYED: 12 19 19 DESIGNED: 11/14/19 MB 11/8/19 DRAWN' MB 8/ 1 / 19 CHECKED: PA BY DATE APPR APPROVED: SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M % CITY 0E RENTON Planning/Building/Public Works Dept. T 1. SEE SHEET C1.0 AND C1.1 FOR GENERAL NOTES, GENERAL STORMWATER NOTES, AND GENERAL SANITARY SEWER NOTES. 2. ALL WORK SHALL BE IN ACCORDANCE WITH CITY OF RENTON STANDARDS AND W 0- REQUIREMENTS. 0- 3. SANITARY SIDE SEWERS SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY OF RENTON z STANDARD 406.2. 0 4. PROVIDE 3' MIN COVER OVER FIRE SERVICE AND FDC LINES. r� 5. DESIGN BUILD FIRE SPRINKLER CONTRACTOR SHALL VERIFY SIZE OF FIRE SERVICE METER U AND FIRE SERVICE, BACKFLOW PREVENTER, AND FDC LINES PRIOR TO CONSTRUCTION. FDC LINES SHALL HAVE CHECK VALVES INSIDE BLDG. 6. STATE OF WASHINGTON LEVEL III FIRE PROTECTION SPRINKLER CONTRACTOR SHALL DESIGN AND PREPARE THE UNDERGROUND SUBMITTAL DRAWINGS PER THE STATE OF WASHINGTON WAC 212-80-043(9). A STATE OF WASHINGTON LEVEL U UNDERGROUND CONTRACTOR SHALL v� PERFORM THE INSTALLATION OF THE UNDERGROUND PIPING PER THE STATE OF WASHINGTON WAC z 212-80-043(2). 0 7. LOCATE ALL WATER METER AND DOUBLE CHECK VALVE BOXES FOR DOMESTIC SERVICES OUTSIDE r , OF MAIN DRIVEWAY AISLES AND PROVIDE TRAFFIC RATED LIDS. V 8. SEE SHEETS C5.0 TO C5.2 FOR APPLICABLE DETAILS. \J_ 9. ALL MECHANICAL JOINT FITTINGS SHALL HAVE RESTRAINED JOINT RETAINER GLANDS EQUAL TO / MEGALUG SERIES 1100 AND CONCRETE BLOCKING. 10. SURFACE MOUNTED UTILITIES SHOWN ON LANDSCAPE SHEETS PER HEARING EXAMINER CONDITION U OF APPROVAL #6. 11. AN AUTOCAD FILE WILL BE PROVIDED TO THE CONTRACTOR FOR LAYOUT OF ALL WORK. STATIONING FOR WATER LINE WORK SHOWN ON WATER LINE PROFILE PLAN SHEET C4.3. 12. SANITARY SEWER MANHOLES SHALL BE PER COR STD DTL 400.2, "SANITARY MANHOLE SHALLOW" SHOWN ON DETAIL 2, SHEET C5.1, UNLESS NOTED OTHERWISE. SANITARY MANHOLES WITH RIM TO LOWEST INVERT DISTANCE GREATER THAN 7.0' SHALL BE PER COR STD DTL 400.1, "STANDARD SANITARY MANHOLE" SHOWN ON DETAIL 1, SHEET C5.1. 13. INDIVIDUAL PRESSURE REDUCING VALVE ASSEMBLIES PER DETAIL 7, SHEET C5.0 SHALL BE INSTALLED ON EACH DOMESTIC WATER SERVICE WITHIN EACH TOWNHOME UNIT DOWNSTREAM OF THE DCVA. 14. CHECK VALVE VAULT TO BE 444 UTILITY VAULT. S-408501 u) 15. BLDG B FDC CHECK VALVE LOCATED INSIDE THE BLDG. W-408502 2 IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0 2 DEVELOPMENT ENGINEERING WASTEWATER UTILITY �' z Nathan Janders 01 /03/2020 Ann Fowler 01 /03/2020 O WATER UTILITY agafour 01 /03/2020 W WILLOWCREST TOWNHOMES DATE:7/29/19 U E D M O N D S AVE NE, RENTON, WA FIELDBOOK: PAGE: 0 DRAWING N0: COMPOSITE U nLITY PLAN C4 •`- SHEET: OF: 14 35 z C7 WATERLINE w�I l I O I N i A (G2) a I' of I THE NORTH LINE OF THE S1/2 OF 1" DOMESTIC WATER PN 092305-9061 THE W1/2 OF THE NW1/4 OF THE 6 DOUBLE CHECK TRI & L LTD PTSHP ROOF ELEV. ° NW1/4 OF THE NW1/4 OF SEC 9, VALVE ASSEMBLY EXISTING BUILDING TWP 23N, RING 5E, W.M. C5.=371.84' PARTIAL FOOTPRINT o (TYP OF ALL BLDGS) I a . 6" SS 2.0% r1ERY8° 54" GATE 30 0' S #5 (TYP) ---' I s 1 88°56' 4'E 7'- - - - ------------- _--- W I WEL NDOW 1- - - - ° A A ° _ 1+00 1 00 UN &CAP N ; I I S L #43 618 bo SIGN i 2" C OSS S p RT m I 3 2 - BLI FLA GE SFWE e�� q 6" S SERVICE,1 oR 5. 5. "TEMP BOW-0 F R NET P PIG STATION P R 3.5 EL FF LL� N a TY BLDG C) APN 722780-1370 C R STD PLAN 300. / I m I I CONICBL CKING REBAR 4 FIRE HY ANT cAP PERRINE LL W 1" OM W LS 43618 S I .° • 3c� , I � , ° , A N - •% ER CE (TYP 74 of 2OF . 3 P) co cmI C5. / �� BLDG A ii S 5 49 145 6 3 3 N ° 6 5 1" STIC WATER a .• d� x PARK BENCH SERDVI EEAND METER I / _ / / (TYP.) - s R.R_TI ALL - ° p 3 II N a AND OUBLE CHE K / C ECK VALVE ULT / I LUI JBIOX COR00 MARE ST SSPLANL 3 0.8 �,_ \ (TY SEE NOTE 14 • i / HEATPUMP VAL TELEPHONE RISER STREET SIGN LUMI�AIRE & JBOX FIRE - HYDRANT SIGNAL - JBOX EPHONE RISER SIGNAL JBOX OF SEC 9, TWP 23N RNG 5E, W.M. PUBLIC SANITARY SEWER MAIN PROFILE 1 (TYP) EX 8" SS MAIN PROFILE SHEET I AND IE (TYP) S88°55'42"E 319.70' I co erra ENGINEERING PLLC 6413 Phinney Ave North Seattle, Washington 98103 ph 206.596.7115 coterraengineering.com 2 DO RECORD DRAWINGS REVISION 4/9/21 SURVEYED: DESIGNED: MB DRAWN: MB CHECKED: PA BY DATE APPR APPROVED: SCALE: 2 WATER MAIN C5. 1-12" COUPLING 12" NIPPLE FOUND REBAR & CA45' HB MJ SSM LS #43612, 436BLOCKING ON SOUTH oC E EX 12" W 1.1'w AS UIRED. FIELD LOCATE LINE AND GRADE PRIOR TO CONSTRUCTION 1988 1 »=20' HORIZO TAL• NAD NAVD1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY EXISTI FOOTP ROOF ELEV.= H POWEF METER a d �\AC�ARPdCARPOf�.T APN 722780-1385 j.. VISSER \ EXISTING HOUSE PARTIAL FOOTPRI� -f - - SANITARY SEWER MAIN - - - - SANITARY SERVICE LINE e CLEANOUT 5 C5. SANITARY SEWER MANHOLE 48" 2 SEE NOTE #12 THIS SHEET. C5. C500110 - - - WATER SERVICE LINE WATER/FIRE MAIN x H WATER VALVE 6 C5. FIRE HYDRANT 4 C5. 5 61 WATER METER C5. H 11.25° BEND �- 22.5` BEND 45- BEND rl 90- BEND WATER CAP # WATER COUPLING 2 C5. 001 WATER REDUCERS IZI WATER TEE 7 ® CONC THRUST BLOCKING HORIZ C5. FIRE DEPT CONNECTION 9 POST INDICATOR VALVE NOTES 1. SEE SHEET 01.0 AND C1.1 FOR GENERAL NOTES, GENERAL STORMWATER NOTES, AND GENERAL SANITARY SEWER NOTES. 2. ALL WORK SHALL BE IN ACCORDANCE WITH CITY OF RENTON STANDARDS AND REQUIREMENTS. 3. SANITARY SIDE SEWERS SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY OF RENTON STANDARD 406.2. 4. PROVIDE 3' MIN COVER OVER FIRE SERVICE AND FDC LINES. 5. DESIGN BUILD FIRE SPRINKLER CONTRACTOR SHALL VERIFY SIZE OF FIRE SERVICE METER AND FIRE SERVICE, BACKFLOW PREVENTER, AND FDC LINES PRIOR TO CONSTRUCTION. FDC LINES SHALL HAVE CHECK VALVES INSIDE BLDG. 6. STATE OF WASHINGTON LEVEL III FIRE PROTECTION SPRINKLER CONTRACTOR SHALL DESIGN AND PREPARE THE UNDERGROUND SUBMITTAL DRAWINGS PER THE STATE OF WASHINGTON WAC 212-80-043(9). A STATE OF WASHINGTON LEVEL U UNDERGROUND CONTRACTOR SHALL PERFORM THE INSTALLATION OF THE UNDERGROUND PIPING PER THE STATE OF WASHINGTON WAC 212-80-043(2). 7. LOCATE ALL WATER METER AND DOUBLE CHECK VALVE BOXES FOR DOMESTIC SERVICES OUTSIDE OF MAIN DRIVEWAY AISLES AND PROVIDE TRAFFIC RATED LIDS. 8. SEE SHEETS C5.0 TO C5.2 FOR APPLICABLE DETAILS. 9. ALL MECHANICAL JOINT FITTINGS SHALL HAVE RESTRAINED JOINT RETAINER GLANDS EQUAL TO MEGALUG SERIES 1100 AND CONCRETE BLOCKING. 10. SURFACE MOUNTED UTILITIES SHOWN ON LANDSCAPE SHEETS PER HEARING EXAMINER CONDITION OF APPROVAL #6. 11. AN AUTOCAD FILE WILL BE PROVIDED TO THE CONTRACTOR FOR LAYOUT OF ALL WORK. STATIONING FOR WATER LINE WORK SHOWN ON WATER LINE PROFILE PLAN SHEET C4.3. 12. SANITARY SEWER MANHOLES SHALL BE PER COR STD DTL 400.2, "SANITARY MANHOLE SHALLOW" SHOWN ON DETAIL 2, SHEET C5.1, UNLESS NOTED OTHERWISE. SANITARY MANHOLES WITH RIM TO LOWEST INVERT DISTANCE GREATER THAN 7.0' SHALL BE PER COR STD DTL 400.1, "STANDARD SANITARY MANHOLE" SHOWN ON DETAIL 1, SHEET C5.1. 13. INDIVIDUAL PRESSURE REDUCING VALVE ASSEMBLIES PER DETAIL 7, SHEET C5.0 SHALL BE INSTALLED ON EACH DOMESTIC WATER SERVICE WITHIN EACH TOWNHOME UNIT DOWNSTREAM OF THE DCVA. Q r� 14. CHECK VALVE VAULT TO BE 444 UTILITY VAULT. R-408535 15. BLDG B FDC CHECK VALVE LOCATED INSIDE THE BLDG. S-408504 CONSTRUCTION RECORD DRAWING THE INFORMATION ON THIS DRAWING INDICATES CHANGES MADE TO THE CONSTRUCTION DOCUMENTS BASED UPON UTILITY AS -BUILT SURVEY PREPARED BY DAVID EVANS & ASSOCIATES, INC., DATED 3/23/21, AND TRANSFERRED TO THE REPRODUCIBLE DRAWINGS BY THE ENGINEER. CITY OF RENTON Planning/Building/Public Works Dept. W-408503 z O v_! Lu I G rr nW I..r. r� v! O n z O Il00000- Z) rr r� VJ z O U \J_ W, u IN COMPLIANCE WITH CITY OF RENTON STANDARDS WILLOWCREST TOWNHOMES EDMONDS AVE NE, RENTON, WA COMPOSITE UTILITY PLAN 7/29/19 PAGE: DRAWING NO: C4.1 SHEEP: OF: 14 3! 0 H H • a J N T O O 0 rn T n vJ Lu 2 O >z O U) Lu U O J J (D M T O O T U V H H H N T O O TO V J ►! n N THE BY-PASS ASSEMBLY SHALL BE INCLUDED AS PART OF THE DETECTOR AS PART OF THE DOUBLE CHECK VALVE ASSEMBLY 4" FL.x'.E. DUCTILE RON CLASS 52 CEMENT LINED PIPE WITH COLLAR 'B" EROM P.E. AS SUPPLIED BY TOUCH READ PIT LID SENSOR PACIFIC WATER WCRKS SUPPLY CO INC. MOUNTED ON STEEL PLATE COVER THROUGH 2" DIA. DRILLED HOLE IN COVER. PRIVATE CITY INSTALL EPDXY NON -SHRINK GROUT P PING PIPING 12" _ 3'-4" LONG T-0" 4" DUCTILE IRON CLASS 53. P.E.xP.E. PIPE. TEE (MJ x FL) CEMENT LINED, LENGTH TO FIT. �. GATE VALVE DEADMAN BLOCK REQUIRED (FL x MS) 2'-4„ 1 " - 4'-8" -_ C_ TO BUILDING 2'. 4„ 2" CONCRETE BLOCKING 12" ,ALL AROUND 4" GATE VALVE (MJ) WITH INDICATOR POST. INDICATOR POST VALVE SAME SIZE AS DOUBLE CHECK VALVE, PAINTED RED. 4" FLANGED COUPLING ADAPTER EQUAL TO ROMAC. .A__ DETECTOR DCLBLE CHECK VALVE ASSEMBLIES SI IALL N;; JDL dLSI L\I LATED S•U'OFF DOUBLE CHECK VALVE ASSEMBLY INCLUDES TWO VA_VES AND T_ST COCKS AN CAPS AND RESILENT SEATED SHUTOFF VALVES. APPROVED CROSS CDNNECLON CONTROL ASSEMBLIES PER D.S.H.S. LATEST APPROVED LIST. PLAN TOUCH READ PIT LID SENSOR U UPRECAST CONCRF-F VA,:LT WITH 2 - Tx3' HINGED MOUNTED ON STEEL PLATE STEEL PLATE COVER. DIMENSION 4'-B' x 7'-0" x 7' 0" COVER THROUGH 2" DIA. UTILITY VAU_- CO. 577-LA OR EQUAL. -GALVANIZED DRILLED HOLE IN COVER. STEEL LADDER r3„ 1 6' TO 46" INSTALL EPDXY q•_3•• NON -SHRINK GROUT (TYP.) I 7'-0" -� , 12" .. I _12„ 2'-9� CONCRETE SUPPORT e PADS OR ADJUSTABLE 1 PIPE SUPPORTS. ELEVATION NOTE: 6" MIN- DRAIN TO DAYLIGHT OR STORM DRAIN SYSTEM INSTALL GALVANIZED LADDER FOR ACCESS. AFTER FIELD IN5TALLA-ION, MAIN DDCVA AND BY-PASS COMPACTED FOUNDATION DCVA MUST BE TESTED SATISFACTORI_Y BY A DEPT. OF GRAVEL HEA TH C-R 11 E) 3ACKFLOW ASSEMBLY TESTER. TEST REPORT TO BE SUBMITTED TC CITY OF RENTON WATER U-ILITY ENGINEERING DFP-. PRIOR TO ACTIVATION OF NEW LINE. INSTALL Y" FLARE TEST COCKS WITH Y4" FLARE CAPS. +► f PUBLIC WORKS 4" DDCV ASSEMBLY WITHOUT STD. PLAN - 360.3 '`•` ` DEPARTMENT STANDPIPE OUTSIDE INSTALLATION MARCH 2O10 OUTSIDE BLDG DDCVA f 1 0 FT X'STING WATER LINE TESTING DETAIL STING TEE, DEAD END LINE, CAP OR PLUG NOT DISTURB BLOCKING NEW WATER LINE VERTICAL CROSS (MJxFL) FOR POLYPIGGING 1 -BLIND FLANGE ON TOP WITH 2"TAP & 2"PLUG 1 -BLIND FLANGE ON BOTTOM 1-PLUG(MJ) W/2"TAP & 2" BLOW -OFF TEMP. BLOCK FINAL CONNECTION DETAIL NEW WATER LINE EXIST. WATER LINE AFTER ALL TESTING, CLEANING BY POLYPIG AND DISINFECTION, REMOVE TEMP. BLOCK & BLOW -OFF & CONNECT TO EXISTING WATER LINE WITH SLEEVE MJ AND D.I. SPOOLS ( ) FINAL CONNECTION BY CITY FORCES �n^�+ PUBLIC WORKS CONNECTION TO WATER MAIN STD. PLAN - 300.5 DEPARTMENT EXISTING TEE OR END LINE CAP "f'FN,ip� MAk01i 2010 EXISTING END LINE CAP CONNECTION TEMPORARY 2" GALVANIZED PIPE AND 2" GATE VALVE 1111SHED GRADE ELEVATION IINST.e.,LL 2" PLUG ON TOP BLIND FLANGE AFTER REMOVAL OF POLYPIG 3 FT MIN. COVER (10-INCH DIAMETER AND UNDER) / 4 FT MIN. COVER (12-INCH DIAMETER AND OVER) ( NEW WATER MAIN POLYPIG ^ -. I VERTICAL CROSS FOR POLYPIGGING STATION: SIZE OF VERTICAL CROSS SHALL BE THE SAME AS SIZE OF MAIN LINE VER-ICA_ CROSS (M" X FL) ONE BLI\D FLANC= ON TOP OF CROSS WITH 2" TAP & 2" TEMPORARY BLOW -OFF ASSEMBLY (REMOVE BLOW OFF ASSEMBLY AND INSTALL 2" PLUG AFTER REMOVAL OF CLEANING "POLY -PIG") ONE BLI\D FLANGE ON BOTTOM OF CROSS ONE PLUG 'MJ) C\ END OF CROSS CONCRETE B_CCKING ALL D-BRIS A\D POLYPIGS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS BEFORE DISINFECTION OF NEW WATER MAIN n PUBLIC WORKS POLY PIG STATION FOR CLEANING OF STD. PLAN - 300.6 DEPARTMENT WATER MAINS biAkCli 2010 POLY PIG STATION OFI RE HYDRANT SHALL BE COREY-TYPE EQUAL TO IOWA F-5110 OR CCIVFRESS ON -Y-E SUCH AS CLOW MEDALLION; M & H 929, MUELLER SUPER CENTJRION 20C, AND WATEROUS PACER WITH 6" MECHANICAL JOINT INLET WITH _UGS. 5-1/4" MAIN VALVE OPENING. TWO 2-1/2" HOSE CONNECTIONS NATIONAL STANDARD THREADS. 4" PUMPER CONNECTION CITY OF SEA`TLE THREADS WITH A STORZ ADAPTOR, 4.875" SEATTLE THREAD X 5" STORZ, ATTACHED WITH 1/8" STAINLESS STEEL CABLE. 1-1/4" PENTAGON OPERATING NUT. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF PAINT. KELLY- MOORE/PRESERVATI VE PAINT No. 5780-563 DTV1 ACRYLIC GLOSS, SAFETY YELLOW OR APPROVED EQJA_. PUMPER CONNECTION TO FACE ROADWAY OR AS DIRFCTED Bv RENTON FIRE DEPARTMENT. FIRE HYDRANT EXTENSION TO BE JSED L-- REOU RED. f MIN. 18" TO 20" BEHIND BACK OF CURB OR 12" BEHIND BACK OF 3' SIDEWALK THAT IS ADJACENT TO CURB 4.875" x 5" STORZ TWO-PIECE CAST IRON VALVE BOX WITH LUG 5x5'x6" THICK CONCRETE PAD AROUND TYPE COVER. EQUAL TO OLYMPIC FOUNDRY CO. HYDRANT. FINISH TO MATCH SIDEWALK. STANDARD 8" TOP SECTION WITH REGULAR BASE ac EXPANSION JOINT AT SECTION LENGTH TO FIT. VALVE NUT EXTENSION BACK OF SIDEWALK AS REQUIRED. fCONCRETE SIDEWALK --- RAISED PAVEMENT MARKER TYPE 88-A OR PLANTING STRIP / STIMSONITE TWO-WAY BLUE REFLECTIVE 36" MIN COVER CONCRETE BLOCKING Y CONCRETE THRUST BOCK MAIN LINE TEE. WITH 6" FLANGE SIDE OUTLET. r 6" GATE VALVE (FL X MJ) AWWA C-509, RESILIENT SEAT 6" DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FI- 2-3/4" COR-TEN STEEL TIE RODS. 16" x 8" x 4" MNINUM 1/2 YARD OF 1-1/4" WASHED DRAIN ROCK CONCRETE B_AINNC; 1' ABOVE BOOT FLANGE. PLACE 8 MIL BLOCK UN-iFR HYDRAN- POLYETHYLENE FILM AROUND TOP AND SIDES OF GRAVEL. FIRE HYDRANT ASSEMBLY LEVEL ALL GROUND LEVEL ALL GRFIUND MIN 3' RADIUS MIN 3' RADIUS iL ONE MAN ROCK D s 6" CONCRETE PAD 6" CONCRETE PAD 41, im CUT FILL HYDRANT I OCATION IN CUT OR FILL Y. n o' PUBLIC WORKS FIRE HYDRANT ASSEMBLY STD. PLAN - 310.1 DEPARTMENT ,11AI{Cli 2010 FIRE HYDRANT CONNECTION NTS C5.2 NTS C5.2 NTS C5.2 NTS 13%24" PLASTC M -ER BOX ECLAL TO MID -STATES PLASTIC, INC BC" SERIES MSBCF 1324 '8 WITH 1.75" THICK DUCTILE CITY PRIVATE IRON DIAMOND PLATE COVER -QUA O MID -STATES PLASTICS, INC. VSC3C-1324-R WILT1 REACER LID AND 2" DRILLED HOLE PIPING PIPING FOR TOUCHREAD PIT LID (SEE )ETAI_ A -A) K I IN UNIMPROVED RIGHT OF WAY INSTALL METER BOX AT PROPERTY LINE WITH 12" W LONG COPPER TAILPIECE. w 9" MIN a I SIDEWALK a 12" MAX -WISH GRADE rr _ z ¢ rc TOUCHREAD WATER - 0 \ METER TO BE O SUPPLIED BY THE 12" z 36" MIN COVER n" CITY ` s> J TYPE "K" SOFT o ' COPPER TUBING j; NEW DUCTLE­ IRON WATFRMA!N IF SERVICE LINE TO HOUSE IS 3/4" OR 1" TO BE INSTALLED IN THE FUTURE GALVANIZED INSTALL FORD C14-33 OR 44 FIPT PLUG x COMPRESSION COUPLING LOOP DOWN TO CENTERLINE OF WATER MAIN TO PROVIDE SLACK IN COPPER COPPERSETTER FOR 5/8"x3/4" METER: FORD SERVICE LINE TO METER. VBH72-15W-44-33G, OR McDONALD BRASS: 21-215WCQQ33, OR MUELLER: 3/4-3-2470-2 WITH ANGLE BALL VALVE ON INLET AND SINGLE CHECK VALVE ON OUTLET - CORPORATION STOP WITH BALL VALVE. FORD COPPERSETTER FOR 1" METR_L FORD VBH72-15W-44-44G, OR TAPERED THREAD (CC). QUICK ..DINT McDONALO BRASS: 21-415WC0044, OR MUELLER: 1-8-2470-2 (3/4" FB1000-3-0) OR AY VCCCNALD 4701E BOTH INLET AND OUTLET WITH QUICK JOINT. PADLOCK WINGS ON (1" F81000-4-Q) OR AY MCDONAI_D 47018 INLET ANGLE BALL VALVE AND SINGLE CHECK VALVE ON OUTLET. ALL FITTINGS SHALL BE WITH QUICK JOINT, NO -. AL.. MFTFR BOXFS INSTALLED WITHIN CONCRETE OR PAVED DRIVEWAYS SHALL BE CASI-IRON EQUAL 0 OLYMPIC FOUNDARY. EXPANSION JOINTS MUSH BE INSTALLED ON 3011- SIDES OF METER BOX. A- A DRILL 2" DIA. HOLE FOR AMR (AUTOMATIC METER READ) 70UCHREAD DEVICE 2-1/2" MIN. FROM NEAREST AND FRONT EDGE OF PIT LID �t TYPICAL RIB I NOTE: THE CENTER OF THE HOLE MUST BE AT LEAST 1" FROM UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS THE NUT TO TIGHTEN AGAINST THE OPEN SIDE OF MORE THAN ONE RB. �Y PUBLIC WORKS 34" AND 1" WATER SERVICE STD. PLAN - 320.1 n `. �'•` �` DEPARTMENT NOVLIMBEI{ 20UD 1" WATER SERVICE A PLAN VIEW A VALVE BOX LID WITH EARS IN DIRECTION OF 2" SQUARE WATER MAIN AND WORD "WATER" OPERATING NUT 12" MIN r_,'�,.'=_"•'" CAST INTO IT 18" MAX 4" CONCRETE COLLAR FOR VALVES IN PAVED AREAS 4-1/4" DIA. 1/8" MIN. THICKNESS SEE DETAIL 2 PIECE CAST IRON VALVE BOX, RICH-SEATTLE TYPE OR OLYMPIC FOUNDRY 1" STEEL LENGTH AS REQUIRED 1/8" MIN. THICKNESS �- 2-1/4" INSIDE MEASUREMENT 2-1/4" DEPTH VALVE OPERATING NUT SECTION A -A EXTENSION VALVE OPc_RAIION NUI EXTENSION NOTE: EXTENSIONS ARE REQUIRED WHEN VALVE NUT IS MORE THAN THREE (3) FEET BELOW FIN S-IED GRAD__. EXTENSIONS ARE TO BE A MINIMIJM 0= ONE (1) FOOT LONG. ONLY ONE EXTENSION -0 BE USED PER VALVE, NOTE: ALL EXTENSIONS ARE TO BE MADE OF STEEL, S ZLD AS NOTED, AND PAINTED WITH TWO COATS OF METAL PAINT. VALVE MARKER NOTES: VALVE MARKERS SHALL BE EQUAL -0 GARSONITE UTILITY MARKER VALVE MARKER PCS- TO BE USED FOR ALL MAIN LINE VALVES OUTSIDE PAVED AREAS a%.. T � _ } 3„ 38" MIN. WIDTH WHITE POST - - 62" j I Ti 24" VALVE MARKER POST Y PUBLIC WORKS VALVE BOX, MARKER &OPERATING STD. PLAN - 330.1 DEPARTMENT NUT EXTENSION ter. MARCH 2010 WATER VALVE BOX NTS C5.2 NTS co errs ENGINEERING PLLC 6413 Phinney Ave North Seattle, Washington 98103 uj ph 206.596.7115 uj coterraengineering.com 2 DO RECORD DRAWINGS REVISION 2 ! 4�_ 11-1/4" BEND 22-1/2' BEND 45' BEND CAP TEE 90' BEND THRUST BLOCK BEARING AREA IN SQUARE FEET (SEE NOTES) FQR HORIZONTAL AND DOWNWARD VERTICAL BENDS SOIL FIRM SILT OR FIRM SILTY SAND COMPACT SAND COMPACT SAND & GRAVEL 90` 45' BEND 11 1/4' 90' 45' BEND 11 1/4' 90' 45' BEND 11 1/4' FITTING BEND TEE CAP OR PLUG & 22 1/2' BEND TEE CAP OR PLUG & 22 1/2- BEND TEE CAP OR PLUG & 22 1/2- BEND BEND 1-) BEND 4' 7.0 42 42 1.7 2.9 2.1 2.1 2.2 1:6 1.6 1.0 6" 13.3 9.4 9.4 3.8 6.7 4.7 4.7 1.9 1 5.0 3.5 3.5 1.4 8" 23 .3 "6,7 16 ? 6.7 11.7 8.4 8.4 3.4 1 8.8 6.3 613 2 3 12" 53.0 3Z5 37.5 15.0 26.5 18.8 I&B 7.5 120.0 14.0 14.0 5.6 AREAS CALCULA. _D ON 300 PSI TESI PRESSURE. S-0- MIN. COVER FOR WAIERMAIN LESS THAN 12". 4'-D" MIN. COVER FOR WATERMAIN 12' OR GREATER. MAX. HEIGI-- ::- IHRUST BLOCK (FT) - 0.5 x DEPTH OF TRENCH MIN. HEIGHT OF THRUST BLOCK (FT) - O.D. PIPE + 1.0' 1RU5T BLOCK BEARING TEA REFERS TO THE ICE DF FLOCK MEASURED IN SQUARE FEET NOTES: 1. LOCATION AND SIZE OF BLOCKING FOR PIPE LARGER THAN 12"DIAMETER AND FOR SOIL TYPES DIFFERENT THAN SHOWN SHALL BE DETERMINED BY THE ENGINEER. 2. ALL BLOCKING SHALL BE POURED IN PLACE AGAINST UNDISTURBED NATIVE GROUND. 3. ALL POURED THRUST BLOCKS SHALL BE BACKFILLED AFTER MIN, 1 DAY. PRESSURE TESTING SHALL OCCUR AFTER CONCRETE HAS REACHED NOMINAL COMPRESSIVE STRENGTH. 4. AL_ BLOCKING SHALL BE CONCRETE CL 5 (1-1/2"). 5. B_CCKING AGAINST FITTINGS SHALL BEAR AGAINST THE GREATEST FITTING SURFACE AREA. POSSIBLE, BUT SHALL NOT COVER OR ENCLOSE BELL ENDS, JOINT BOLTS OR GLANDS REASONABLE ACCESS TO BOLTS AND GLANDS SHALL BE PROVIDED. Tt ° CONCRETE BLOCKING FOR STD. PLAN - 330.2 PUBLIC WORKS HORIZONTAL AND DOWNWARD DEPAh''PMENT VERTICAL BENDS MARCH 2010 CONCRETE THRUST BLOCKING NTS 4/9/21 SURVEYED: DESIGNED: MB DRAWN: MB CHECKED: PA BY DATE APPR APPROVED: SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL, NAD 1983/1991 DATUM CONCRETE DEAD MAN BLOCKING WITH SHACKLE RODS TO CAP, BLOCK SHALL BE POURED AGAINST UNDISTURBED E.ARTI, SIZE OF BLOCK TO BE DETERMINED DASED ON TEST PRESSURE OF WATER LINE .AND SOIL CHARACTERISTICS. ,`�, ,R ,•skCAST IRON CAP OR PLUG WITH �.� 2" IPS TAP SHALL BE A ROCKWELL 482 END CAP COUPLING. WATER MAIN I 2" GALVANIZED IRON PIPE - AS REQUIRED. 2" CLOSE NIPPLE 2" 90' ELBOW 2" GALVANIZED IRON PIPE. 12" LONG. PLAN TWO PIECE CAST IRON VALVE, BOX I EQUAL TO RICH VALVE CO. STANDARD 8" TOP SECTION, WITH REGULAR BASE SECTION LENGTH TO FIT. 2" CA_VAN ZE IRON PIPE 12" 1 ONG VALVE NUT EXTENSION IF REQUIRED ;SEE DWG BR46 / PACE B090) / INSTALL 2" 90- ELBOW, SCREWED -� 2" PLUG, SCREWED i _- 2" GALVANIZED IRON PIPE AS REQUIRED. 2" RESILIENT GATE VALVE, SCREWED INSTALL 2" 90' ELBOW, - ✓ SCREWED 2" GALVANIZED IRON PIPE AS REQUIRED. ELEVATION 1 STD. PLAN - 340.2 1' Gr °+ PUBLIC WORKS_ 2" BLOW -OFF ll1PAP.I'MENT TEMPORARY ASSEMBLY MAR(.I1 �010 2' BLOW OFF ASSEMBLY NTS CONSTRUCTOR RECORD DRAWING THE INFORMATION ON THIS DRAWING INDICATES CHANGES MADE TO THE CONSTRUCTION DOCUMENTS BASED UPON UTILITY AS -BUILT SURVEY PREPARED BY DAVID EVANS & ASSOCIATES, INC., DATED 3/23/21, AND TRANSFERRED TO THE REPRODUCIBLE DRAWINGS BY THE ENGINEER. +_ CITY OF RENTON Planning/Building/Public Works Dept. CO M T Nt O T 01i u0 ^r 11 Z O 0 W co L C) o W 0 z O I- U I- v/ z O U \J_ IS LJ R-408541 W-408505 w 75 IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0 2 WILLOWCREST TOWNHOMES EDMONDS AVE NE, RENTON, WA CITY OF RENTON CML DETAILS >z O W DATE: 7/29/19 V FELDBOOK: PAGE: O DRAWING NO: J C5.2 `J SHEET: OF: 19 35