HomeMy WebLinkAboutS-408507N
DocuSign Envelope ID: 7CDD88BC-C843-439E-9366-C6DBBOFBBBB7
7'
'q0I 10 5i_ALL
MANHOLE FRAME AND COVER
SFF S-0. PLAN 421
A-:,:11STM-N- RINGS ANC M:)RTA.R JOINTS
';Er NCIE 5
CONE (ECCENTP.C)
RURFIFR ',ASK-TF) J',)IN-C IN
ACC HL)D %NCL 'Ad ti `,,SAl C �d,)
STEPS - PC_" F'RCPYLENC STEPS
SHA__ BE INCL-DEC
CONCRETE RRISER. B'" ,IPE INC
OR APPROVED ECUA_. -
v.D-R P IY ROPYLENE
,HA-_ Bt A LACHED TO MAN-OLE
MAX. PIPE SIZE - 'E'
CONCRETE S-ELF
PRECAST BASE SECTION.
OR CAS- IN SHE_=.
A,
B,
,C,
'D'
,E,
p �
4, h,H 18
- I�•
b M J.
5 , •.1L• J
21 tv SIN I
C.
"4" MH 54"
8" MIN
5.5" VIN.
24" MIN.
/4 L ?.
5C" hA 5l'
8" MIN
"MIN_
42" MIN,
30I.U.
NOTES:
I. sTFPS TO BF POI Y-RUP rl F'",F Fr ` TFPS.
2. S I EPS ARt 10 BE IN PLACE B F ^ ' ° FdHCLE SEC I IONS ,"•.RE NS I ALLED.
3. CASTING S ALL BE PE: STD. F-
4. "AANHO17 3ECTICN= TC BE OF F =ED PRECAST CO\CRETE.
5. ADJ_STM. NT OF THE CASTING L- SHALL BE PEP, STD PLAN 106. TH= USE C= SHIMS IS PRGH'31TED.
a SANITARY SENiER MANHOLE",`:H�.11- ,E ALL INTERIOR tiURFACES, INCLUDING CHANNELING,
COATED (SEALED) 'N TH r, H :;H _i � URET-ANE CU ATING; AASSER MC -SHIELD; CAT "CC OR
API'RO'•/ED EQUAL COLOR OF C.C;A III'J:_ SHALL BE 'A"HI-E.
r ,
RUBBER GA.SKETEC JCIr T -A.I 1_ BE IN C:�NF')Rh,'ANCE ,.ITH ATM 4L?
8. 'CH,AN\EL HEIGHT SHALL E MIN MUN OF 3/4 OF TH- INSIDE DIAMETER r__ THE _ARG, S'T =11`=
9. C'ONN_CIIONS IO VANHL__ SHALL BE MADE USING GI'K AI2AIPICN. -'JN `, _EAL BOOIS OH
A.PPROV'FFI FJUAI
10. IN UNIMPROVED AREAS, M.AN-OLEO, SHALL EXTEND A MINIMUM O- 6" AND A r14' IVUt•A 07 12"
ABOVE ` IN SHED GRADE OR MUST HAVE A MI\IMLJr.1 2' DIAMETER CCNCF E F I I r I I FF -.F =.D=
N PAV-D AkLAS, COVER MUSI SLOPE IN ALL -IRE! (IONS 10 MATCH PAVING
11. MANH LLI CVL. 20' DtFI SHALL BE A VINIhaUH OF 60" III _�I'tNEI R.
D� STD. PLAN - 400.1
•�. PUBLIC WORKS PROVED:
DEPARTMENT STANDARD SANITARY MANHOLE GAZ 9/11/2019 1
a.cswa+�wmn'^u, DATE
1 STANDARD SANITARY MANHOLE
NTS
DocuSian Envelope ID: 7CDD88BC-C843-439E-9366-C6DBBOF8BBB7
2:12 P
r<q r--i-r----------
I�� EX. SEWER MAIN
PROPERTY LINE
F
IIIz IIAS NEEDED) iii1 3•-0" MIN.WER STUB I FUTURE 4" SIDE SEWER
tjj
i2"x 4" STUD MARKING POST PAINTED
6" CAP WHITE WITH THE WORD "SEWER" STENCILED
EE X 6" TEE i i i i I IN 3" HIGH BLACK LETTERS AND g6 WIRE
I I I I• w WRAPPED AROUND THE STUD AND
I I I SIDEWALK I • z EXTENDED TO THE TOP OF THE STUD.
COUPLING (TYP.) L_J_L___-_----J : Q
ta,
6"X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER
i (EAST JORDAN IRON WORKS PRODUCT NO. 00367502 OR
APPROVED EQUAL, SPECIFY "SEWER" ON LID),
CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD.
CONCRETE PAD TO BE 8" IN DEPTH.
i 1
L___J
BEND AS �� g"
REQUIRED
/'EXISTING SANITARY -a
/ SEWER MAIN �-2.07.. MIN. SLOPE \\
! \ ` FUTURE 4" SIDE SEWER
�6" SEWER STUB `6"X6"X6" WYE FUTURE 6"x 4" REDUCER
SEWER MAIN 512E X 6" TEE
ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN
A. VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
B. CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
C. PVC & C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE
(OR APPROVED EQUAL).
D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL)
E. LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC.); CUT IN A NEW PVC "TEE" USING
"STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
F. HDPE - CORE -DRILLED WITH A ROMAC SADDLE. "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER.
G. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE
SHALL BE CORE -DRILLED.
OVA
3000 CONCRETE X /Ny
BLOCKING _-- 2%
M / / CONOE� _2q; MIN SLOPE
HORIZONTAL
I 6' TEE
6" MIN. SEWER SEWER MAIN
MAIN
CONCRETE BLOCKING ANGLE
OF TEE AT MAIN BETWEEN 25' AND 45' TYPICAL SIDE SEWER
NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5'
LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER.
PUBLIC WORKS
SIDE SEWER STUB STD. PLAN -406.1
.a�• APPR °'
P„ DEPARTMENT INSTALLATION GAZ 9/11/2019 1
VtOF (SEWER MAIN TO PROPERTY LINE)
ruuxwo.�adml DATE
SIDE SEWER AND CLEANOUT INSTALLATION
:12
DocuSign Envelope ID: 7CDD88BC-C843-439E-9366-C6DBBOFSBBB7
MANHOLE FRAVE AND COVER
PER STD. ILAN 401
AD,•U .TV T RINGS
AND r,4CRT `R ,.CANT
SLL NOIE s
• '� 4" hAIPJ. TO
12" MAX.
24„
a° \ n e u L
d
� OL
1L' N is
+ W
a >
4
a
° e .
d V G
a e
d ° a v 1T
6r,
NOTES:
1. STEPS TC PnI YF ,OP FNF SA -FT, STFP`;.
2. STEPS APT 1 IN P A( EFF R- MANH)F SFCTIONS .ARE INSTALLED.
1. CA`_.TIN, 'I I L =R SID. 'LAN 401.
4. I\4ANH I 1C B_ J- H.LIN FOH'C'ED 'RECAST CONCRETE.
5. AD.,II_,-= C.ASTRJG TO CONCRETE-
- -E SHALL BE PER STD P-AN 106.
THE ('.'--,E C,F .`_H11:.1`I IS PR.-1I-•ITED.
6. SANITARY SF1hTR A4A'JFCLES ?IAII IIA'VF ALL INT171,11.07 S. FAC ,. INCLUDING CHANN--ING,
OAT ? �_E,ALED) '04TH A HIGH _DUDS URE-HANE COATING; WASSER
PAC_�!d1 r ;OAT 100 OR APPROy-C FOUAI C'OICR COATING, SHAII BE *HITF.
RULs3L. L,ASKLILD JOINTS SHALL 3L IN CONFORMANl L 'WIIH ASIM C-443.
v CI IANPJFI FIC-11- `-.IIAI I fir .4 h•11V14✓.,'od CiF 3/4 TI IF INSI-F F)1,4MFTFR OF THE I A.RG -'IPF.
9. CCNNFCTIC)NS T) MANHOI F SHAI I BE MADE- I:SINC CPK A --AFTER, KOR-N-SFAI
BOu S ON ,Al''ROVED -QJAL.
- -
I_. IN UNIMPROVED ,�'E � D;1'IJH�LES _H. LL TIC. A r.AINIMJha ,. b AND A. 4 11^✓.>,I OF
12" ABOVE F"V HEU JRAD J- MUol Hi`•._ A MINIMUIvi 2' UTAMETLIH CONCHE FINGS
POURED AT GRACE IN AREAS, COVER MUS- SLOPE IN ,ALL DI4EC71;,NS -C' VATCH PAVING.
STD. PLAN - 400.2
iR PUBLIC WORKS SANITARY MANHOLE APP a ED:
DEPARTMENT SHALLOW GAZ 9/11/2019 1
DATE
SANITARY MANHOLE SHALLOW
NTS
DocuSign Envelope ID: 7CDD88BC-C843-439E-9366-C6DBBOFBBBB7
38"
POST
62"
24"
SEWER MANHOLE MARKER POST
SEWER MANHOLE MARKER NOTES:
SEWER MANHOLE MARKER POST SHALL BE EQUAL TO
CARSONITE UTILITY MARKER
SEWER MANHOLE MARKER POST TO BE USED FOR
SANITARY SEWER MANHOLES IN UNIMPROVED AREAS.
SEWER MANHOLE MARKER POST SHALL IDENTIFY THE
MANHOLE AS "SANITARY SEWER".
STD. PLAN - 404.2
r PUBLIC WORKS PPR D`
��1 DEPARTMENT SEWER MANHOLE MARKER POST GAZ 9/11/2019 I
DATE
0 SEWER MANHOLE MARKER POST
NTS C5.1 NTS
coterra
ENGINEERING PLLC
6413 Phinney Ave North
Seattle, Washington 98103
uj
ph 206.596.7115
Ld coterraengineering.com
2 DO
RECORD DRAWINGS
REVISION
:12 PM
:12 PP
DocuSign Envelope ID: 7CDD88BC-CB43-439E-9366-C6DBBOF8BBB7
BOLTHO_ES - 3 PiCS
EQUALLY SPACED 120"
APART =N 23 1/16' C586'r
TJIA 3L :SEE ➢F-AII
RENTON
\ O
z SEWER °
COVER & FRAME
PLAN VIEW
r:," D
C635rtP�J _
�; �' ��-srnr•�J
C1`�'•Ir�J
COVER SECTION VIEW
26 lit' DIA
_
CG73nr^J
�c 1.'4'
1 1/1G"
1
� -
C�_7n-)
h.LJFk-NL _ _ L I
1 6TTA
t
Cl�c-'r�J
1
-1
L16rrr'
L59%'IgPJ y
_ 27 t/.6° ICA
-'94mr7
;4 ' /C DIA_
COVER BOTTOM VIEW
JLI S=L - LL__N HEAD)
3/R X 1. T S
LI�13EN WAASHLR
BOLTING DETAIL
'✓4' 1 1/16'
LSInnJ -
t [P7Mm-
t
C3nrn]
GASKET GROOVE DETAIL
67mml NOT
FRAME SECTION VIEW 1, A._L _: )'.L <S -,I ALL HL L: LIP NL < L..;=-1
F_FI:AN 1-01,1 .. F �'7CI `)H FOI.141
2 I L I PAI4L AN, P_ I I,I (;PLCI Y
L J )N "L I EC 1 1,
F•JF� L 'r ��T vTFR7'';.
pp�� STD. PLAN - 401L
PUBLIC WORKS PPROVED:
DEPARTMENT MANHOLE FRAME AND COVER GAZ 9/11/2019 1 2
wniK w.,x„amm„o-.,u. DATE
MANHOLE FRAME AND COVER
NTS
DocuSign Envelope ID: 7CDD88BC-C843-439E-9366-C6DBBOFBBBB7
W (SEE NOTE 7) LIMITS OF PIPE ZONE
1 -0"
BEDDING MATERIAL FOR
SANITARY SEWER PIPE ; O.D. OF PIPE
(SEE NOTE 5)
FOUNDATION LEVEL
6„
BEDDING FOR SANITARY SEWER PIPE
NOTES:
1. PROVIDE UNIFORM SUPPORT UNDER BARREL.
2. HAND TAMP UNDER HAUNCHES.
3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY
OVER PIPE. HAND TAMP ONLY.
4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE
STANDARD SPECIFICATIONS.
5. PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3)'
OF THE STANDARD SPECIFICATIONS OR PEA GRAVEL.
6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW
LINE IS MAINTAINED.
7. TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE
STANDARD SPECIFICATIONS.
STD. PLAN - 405
PUBLIC WORKS PIPE BEDDING [PP"O'VID:
,1` DEPARTMENT FOR SANITARY SEWERS GAZ 9/11/2019 I
DATE
0 PIPE BEDDING FOR SANITARY SEWER
NTS
4/9/21
SURVEYED:
DESIGNED: MB
DRAWN: MB
CHECKED: PA
BY
DATE
APPR
APPROVED:
SCALE:
1 "=20'
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL NAD 1983/1991
DATUM
:12 P
:12 PN
DocuSign Envelope ID: 7CDD88BC-C843-439E-9366-C6DBBOFBBBB7
TEE OF APPROPRIATE SIZE
r
SEE NOTE 6
"RELINER" BRAND STAINLESS
STEEL ADJUSTABLE CLAMPING
BRACKETS OR APPROVED EQUAL
e'
:r 90° BEND
3/4 THE DIAMETER OF
' THE DOWNSTREAM PIPE
NOTES:
1. SANITARY SEWER MANHOLE DROPS ARE ONLY TO BE USED UPON
APPROVAL BY THE WASTEWATER UTILITY SECTION.
2. ALL PIPES AND FITTINGS SHALL BE SIMILAR SIZE AND MATERIAL
AS INCOMING MAINLINE.
3. MINIMUM SIZE MANHOLE FOR INSIDE DROP CONNECTION SHALL BE
60" DIAMETER.
4. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR,
KOR-N-SEAL BOOTS OR APPROVED EQUAL.
5. WITHIN A 60" DIAMETER MANHOLE, THE MAXIMUM ALLOWABLE DIAMETER
OF THE INSIDE DROP PIPING IS 12". INSIDE DROPS EXCEEDING 12" IN
DIAMETER OR MULTIPLE DROPS SHALL BE REVIEWED BY THE WASTEWATER
UTILITY AND MAY REQUIRE A LARGER DIAMETER MANHOLE.
6. "RELINER" BRAND STAINLESS STEEL ADJUSTABLE CLAMPING BRACKETS
OR APPROVED EQUAL SHALL BE INSTALLED WITHIN 6" OF
BOTH BELL AND SPIGOT ENDS OF EACH DROP PIPE.
IF DROP PIPE LENGTH EXCEEDS 5 FEET THEN CENTER STRAPS
SHALL BE INSTALLED WITH A MAXIMUM SPACING OF 4 FEET
ON CENTER. BRACKETS SHALL BE ATTACHED UTILIZING STAINLESS
STEEL EXPANSION BOLTS, MIN. 2 EACH AT CONNECTION POINTS.
STD. PLAN - 402.2
.r.� PUBLIC WORKS INSIDE DROP CONNECTION D
DEPARTMENT GAZ 9/11/2019 I
VR]FOR SANITARY MANHOLE
DATE
INSIDE DROP CONNECTION
NTS
CONSTRUCTOR
RECORD DRAWING
THE INFORMATION ON THIS DRAWING
INDICATES CHANGES MADE TO THE
CONSTRUCTION DOCUMENTS BASED
UPON UTILITY AS -BUILT SURVEY
PREPARED BY DAVID EVANS &
ASSOCIATES, INC., DATED 3/23/21, AND
TRANSFERRED TO THE REPRODUCIBLE
DRAWINGS BY THE ENGINEER.
0 CITY OF
RENTON
Planning/Building/Public Works Dept.
:12 PP
R-408540
0I
0
uS
r l
•
T
a
J
z
0
VJ
W
L C)
o
W
Ir-n n
V
O
z
0
I-
U
U)
z
O
U
J_
IS
Lm
S-408507 w
45
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0
2
WILLOWCREST TOWNHOMES
EDMONDS AVE NE, RENTON, WA
CITY OF RENTON CML DETAILS
>z
O
W
DATE:
7/29/19 U
FIELDBOOK:
PAGE: O
DRAWING NO: J
C5.1 `J
SHEET: OF:
18 35