Loading...
HomeMy WebLinkAboutS-409112(I) Z J V J n 5< G ----------- --EX. SEWER MAIN 1 1 i l PROPERTY LINE SPOOL i g (LENGTH AS NEEDED) I 0 6" SEWER STUB i I I i ;•� FUTURE 4" SIDE SEWER ( DC----------� I I I + /// 2"x 4" STUD MARKING POST PAINTED • 6" CAP J WHITE WITH THE WORD "SEWER" STENCILED SEWER MAIN TEE X 6" TEE i i I N 3" HIGH BLACK LETTERS AND #6 WIRE SIDEWALK i : z WRAPPED AROUND THE STUD AND i l EXTENDED TO THE TOP OF THE STUD. COUPLING TYP. } V TJ 1 6"X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER 01 (EAST JORDAN IRON WORKS PRODUCT NO. 00367502 OR APPROVED EQUAL, SPECIFY "SEWER" ON LID), CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD. Of CONCRETE PAD TO BE 8" IN DEPTH. - ------------------------T- r - ---j BEND AS 8" REQUIRED EXISTING SANITARY SEWER MAIN !!! --2.0% MIN. SLOPE l \ ` FUTURE 4" SIDE SEWER SEWER STUB `6"X6"X6" WYE FUTURE 6"x 4" REDUCER `SEWER MAIN SIZE X 6" TEE ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN A. VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B. CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). C. PVC & C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL). D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E. LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC.); CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). F. HDPE - CORE -DRILLED WITH A ROMAC SADDLE. "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER. G. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED. 3000 PSI MIX /�h �NOJS CONCRETE ' �- / PNGOG�\NG BLOCKING �� 1 �\N / 7, 2G NCR 2% MIN SLOPE HORIZONTAL I 6" TEE 6" MIN. SEWER SEWER MAIN MAIN CONCRETE BLOCKING ANGLE OF TEE AT MAIN BETWEEN 25' AND 45' TYPICAL SIDE SEWER NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. SIDE SEWER STUB VED: STD. PLAN -406.1 .•�• PUBLIC WORKS APPR DEPARTMENT INSTALLATION GAZ 9/11/2019 (SEWER MAIN TO PROPERTY LINE) b1 w° .Adm„s a° DATE BEDDING MATERIAL FOR SANITARY SEWER PIPE (SEE NOTE 5) FOUNDATION LEVEL W (SEE NOTE 7) LIMITS OF PIPE ZONE 1'! O„ O.D. OF PIPE �„ BEDDING FOR SANITARY SEWER PIPE NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE STANDARD SPECIFICATIONS. 5. PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3)' OF THE STANDARD SPECIFICATIONS OR PEA GRAVEL. 6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED. 7. TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE STANDARD SPECIFICATIONS. STD. PLAN - 405 PUBLIC WORKS PIPE BEDDING P P R CY75 D: ;k DEPARTMENT FOR SANITARY SEWERS GAZ 9/11/2019 1 P.mm works Aam'~ramr DATE l Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) �. P I ED/ �O of WASyl sC' tic 3232 GISTF ID �SS�ONAL 8 ill mRL NA.- :12 :12 PN NE 9/4 SECTION 14, TOWNSHIP 23 N, RANGE 5 E, W.M. &MPLE HIGHLANDS BOLTHOLES - 3 PLCS sNaon r+oa� EQUALLY SPACED 120° Nvaaor isv3 APART ON 23 1/16' (586mm) DIA B.C. (SEE DETAIL) R E rr o� SEWER COVER & FRAME PLAN VIEW 25' DIA. C635mm] 1" 3/4"25mm] [19mm] 8 3/4" 1 2 1/2" C222mm] C64mm] TYP COVER SECTION VIEW 26 112' DIA C673mm] 25 1/4' DIA C641mm] 1 1/16" 1/4" (6mm) DIA C27mm] NEOPRENE GASKET q�� 6" C151 mm] 5/8' 23 3/8" DIA CL OPEN C16mm] [594mm] 27 5/16' DIA C694mm] 34 1/8' DIA C867r,r,] NOTES: FRAME SECTION VIEW 1. ALL COVERS SHALL BE LOCKING LID PER EAST JORDAN IRON WORKS INC. No. 3717C1 OR EQUAL. 2. USE FRAME AND COVER FOR STORM (SPECIFY "DRAIN" ON COVER), SANITARY (SPECIFY "SEWER"), OR WATER (SPECIFY "WATER"). STD. PLAN - 401 V4R) •PUBLICWORKS PPR D: DEPARTMENT MANHOLE FRAME AND COVER GAZ 9/11/2019 1 Iftor vvbuc w«ks Aemmsnacar DATE COVER BOTTOM VIEW (3) BLT SOC. (ALLEN HEAD) 5/8"-11 X 1.5 SS RUBBER WASHER BOLTING DETAIL NOT TO SCALE 1/4' 16mm] [27mm] C3mm] v8" CR3mm] GASKET GROOVE DETAIL MANHOLE FRAME AND COVER SEE STD. PLAN 401 ADJUSTMENT RINGS AND MORTAR JOINTS SEE NOTE 5 CONE (ECCENTRIC) RUBBER GASKETED JOINTS IN ACCORDANCE WITH ASTM C-443 STEPS - POLYPROPYLENE STEPS SHALL BE INCLUDED CONCRETE RISER BY PIPE INC., OR APPROVED EQUAL. LADDER -POLYPROPYLENE SHALL BE ATTACHED TO MANHOLE MAX. PIPE SIZE - 'E' CONCRETE SHELF PRECAST BASE SECTION OR CAST IN SHELF. A' 'B' 'C' 'D' 'E' 48" MH 48" 6" MIN. 5"MIN 24" MIN. 21" 1. D. 54" MH 54" 8" MIN. 5.5" MIN. 24" MIN. 24" I.D. 60" MH 60" 8" MIN. 6" MIN. 42" MIN. 3 0 " 1. D. NOTES: 1. STEPS TO BE POLYPROPYLENE SAFETY STEPS. 2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED. 3. CASTING SHALL BE PER STD. PLAN 401. 4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE. 5. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE PER STD PLAN 106. THE USE OF SHIMS IS PROHIBITED. 6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC-SHIELDCOAT 100 OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE. 7. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443. 8. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE. 9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL. 10, IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12" ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RING POURED AT GRADE. IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. 11. MANHOLES OVER 20' DEEP SHALL BE A MINIMUM OF 60" IN DIAMETER. STD. PLAN - 400.1 • PUBLIC WORKS PRo DEPARTMENT STANDARD SANITARY MANHOLE GqZ 9/11/2019 I wmm . DATE 1 CITY COMMENTS 11.12.19 D.R. STRONG 2 INTAKE COMMENTS CONSUL TING ENGINEERS 3 CITY COMMENTS 07°27°21 ENGINEERS PLANNERS SURVEYORS 620 - 7/h AVENUE KIRKLAND, WA 98033 O 425.827.3063 F 425.827.2423 NO. REVISION 2:12 P 2:12 P SANITARY SEWER NOTES AND SPECIFICA TIONS.- 1. ALL WORK AND WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF T APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT. AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN PUBLIC RIGHT OF WAY. (] C) J. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR O7 DISTURBANCE. r U 4. A PRE -CONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON.) IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 7. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 9. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. Co co 10. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE (DTHE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. O 11. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED (] BY THE CITY OF RENTON. 01 12. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 198JI1991 METERS UNLESS T OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 13. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE J COMPLETION OF CONSTRUCTION. 14. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE PIPE. 15. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE WASTEWATER UTILITY. 16. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 12 INCHES ABOVE FINISHED GRADE OR MUST HAVE MINIMUM 2' DIAMETER CONCRETE RING POURED AT GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. RECESSED LIFT POCKET 3/4" LETTERING "SEWER" e SEWER a (2) BOLT SOC. (ALLEN HEAD) 5/8" - 11 X 1.5 STAINLESS STEEL REF. PART #00981177 0 � 0 -3/16" 10-1/2" 5/! 1/4" 12-1/2 1„ -T1-1/8„ 2-1/4" CAST IRON RING AND COVER Not to Scale FRAME 1'-n" I IAkA== 1'-0" 45- (1/8) BEND OR DABLE PIPE MATERIAL AS SPECIFIED BY THE ENGINEER NOTES: 1. 8" AND 6" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC. No. 3698 (PRODUCT NO. 00369803) OR APPROVED EQUAL. CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY. 2. IN UNIMPROVED AREAS, POUR A 8" THICK, 2'-0" SQUARE CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER. PUBLIC WORKS V`R] DEPARTMENT YLP 02.14.20 YLP SURVEYED: DJC YLP 06°16°21 YLP DESIGNED: YLP YLP 08.13.21 YLP DRAWN: GLB CHECKED: YLP BY DATE APPR APPROVED 8" OR 6" CLEANOUT FOR SANITARY SEWER MAIN SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 QATUM STD. PLAN - 403.1 'P ED: GAZ 9/11/2019 ,nc work, Aamm�,nawr DATE :12 • C TY OF RENTON Planning/Building/Public Works Dept. S-409112 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Cn WASTEWATER UTILITY Ann Fowler 09/30/2021 A004 0 Q J DEVELOPMENT ENGINEERING njanders 10/01 /2021 2 0 _ W MAPLE HIGHLANDS SANITARY SEWER DETAILS 16210 SE 134TH STREET RENTON, WASHINGTON 98059 DATE: 09.05.19 J FIELDBOOK: PAGE: DRAWING C39 SHEET OF: 39 41 DRS PROJECT NO. 17020