Loading...
HomeMy WebLinkAboutR-406312_J _J LLJ m Q 7E Q N (D N 7p Q i rn co i u) 0 / rn O° i 0 0 0 00 w ® SITE DEVELOPMENT NOTES: 1. PROPOSED CHICK-FIL-A RESTAURANT. SEE ARCHITECTURAL PLANS. 2. PROPOSED ASPHALT PAVEMENT. SEE DETAIL 21/C11.2. 3. PROPOSED CONCRETE PAVEMENT DRIVE-THRU. SEE DETAIL 25/C11.2. 4. PROPOSED SPILLING CURB AND GUTTER (TYP). SEE DETAIL 17/C11.1. 5. PROPOSED BARRIER CURB (TYP). SEE DETAIL 5/C11.4. 6. PROPOSED ADA COMPLIANT SIDEWALK ACCESSIBLE RAMP. SEE DETAIL 7/C11.0. 7. PROPOSED TRASH ENCLOSURE. SEE ARCHITECTURAL PLAN FOR TRASH ENCLOSURE DETAILS. 8. PROPOSED BOLLARD WITH MOUNTED ADA ACCESSIBLE PARKING SIGN. SEE DETAIL 6/C11.0. 9. PROPOSED ON -SITE CONCRETE SIDEWALK. SEE DETAIL 11 AND 12/C11.0. 10. PROPOSED DIRECTIONAL PAVEMENT MARKINGS (TYP). SEE DETAIL 1 AND 2/C11.0 AND 32/C11.3. 11. PROPOSED SIGN. SEE SIGN PLAN. 12. PROPOSED 4" WIDE WHITE REFLECTIVE PAINT PARKING STALL STRIPES PER PAINT STRIPING PROJECT SPECIFICATIONS (TYP). 13. PROPOSED LANDSCAPING PER LANDSCAPE AND IRRIGATION PLANS. 14. SAWCUT IN A SMOOTH CONTINUOUS LINE (TYP). 15. PROPOSED 18" STEP OFF CURB (TYP). SEE DETAIL 4/C11.4. 16. PROPOSED ADA STALL STRIPING AND MARKING. SEE DETAIL 4 AND 5/C11.0. 17. PROPOSED CONCRETE SECTION AND APRON FOR TRASH ENCLOSURE. SEE DETAIL 24/C11.2. 18. PROPOSED ORDER POINT STRIPING. SEE DETAIL 27/C11.2. 19. PROPOSED BIKE RACK. SEE ARCHITECTURAL PLANS. 20. PAVEMENT EDGE. SEE DETAIL 21A/C11.2. 21. PROPOSED FLAG POLE. SEE SEPARATE SIGN PLANS FOR ADDITIONAL DETAILS. 22. DRIVE-THRU ORDER POINT ISLAND CURB. SEE DETAILS 34/C11.3. 23. PROPOSED DRIVEWAY MODIFIED FROM RENTON STANDARD PLAN 104.4. CONSTRUCT DRIVEWAY CURB PER CITY OF RENTON STANDARDS AND TIE INTO EXISTING CURB. MATCH EXISTING ELEVATIONS AT CURB TIE IN. SEE DETAIL 3/C11.4 FOR SLOPING AND CURB REQUIREMENTS. DRIVEWAY CONSTRUCTION TO BE COMPLETED DURING CITY APPROVED TIME. COORDINATE APPROVED WORK HOURS AND RESTRICTIONS WITH THE CITY PRIOR TO CONSTRUCTION. 24. PROPOSED HEIGHT CLEARANCE ARM. SEE SIGN PLANS. 25. PROPOSED CONCRETE V-SWALE. SEE DETAIL 6/C11.4. 26. PROPOSED STRUCTURAL COLUMN AND SCREEN WALL. SEE ARCHITECTURAL PLANS. 27. PROPOSED MENU BOARDS. SEE ARCHITECTURAL PLANS. 28. PROPOSED BOLLARD. SEE DETAIL 20/C 1 1.1. 29. PROPOSED OFF -SITE SIDEWALK PER CITY OF RENTON STANDARD PLAN 102. SEE DETAIL 1/C11.4. 30. PROPOSED OFF -SITE CURB PER CITY OF RENTON STANDARD PLAN 101. MATCH EXISTING ELEVATIONS AT CURB TIE IN. SEE DETAIL 2/C11.4. 31. NOT USED. 32. DRIVE-THRU ORDER POINT CANOPY, SEE ARCHITECTURAL PLANS. 33. PROPOSED TRANSFORMER. SEE SHEET C10.0 FOR ADDITIONAL DETAIL. 34. PROPOSED BENCH LOCATION, SEE LANDSCAPE PLAN SHEET L5. 35. PROPOSED ADA NO PARKING SIGN. SEE ARCHITECTURAL PLANS. 36. PROPOSED PERVIOUS CONCRETE SIDEWALK. SEE SHEET C5.0 FOR ADDITIONAL DETAIL. 37. PROPOSED CANOPY STRUCTURAL COLUMN (TYP). SEE ARCHITECTURAL PLANS. 38. PROPOSED PLAZA AREA. SEE ARCHITECTURAL AND LANDSCAPE PLANS. 39. PROPOSED CONCRETE STEPS, SEE GRADING PLAN FOR DESIGN INFORMATION AND ELEVATIONS, SHEET C4.1 AND SEE LANDSCAPE PLAN SHEET L5 FOR DETAILS. 40. PROPOSED CMU SCREEN WALL WITH STUCCO FINISH, SEE GRADING PLAN FOR DESIGN ELEVATIONS, SHEETS C4.0 AND C4.1. SEE STRUCTURAL PLANS FOR DETAILS. 41. PROPOSED LOT LIGHT. SEE SEPARATE LIGHTING PLAN. 42. NOT USED. 43. PROPOSED MONUMENT SIGN. SEE SEPARATE SIGN PLAN FOR ADDITIONAL DETAILS. 44. CONTRACTION JOINTS IN CONCRETE (TYP), SEE DETAIL 28/C11.2. CONTRACTION JOINTS SHALL BE SPACED AT 12' MAX. ALIGN DRIVE-THRU CONTROL JOINTS WITH CURB CONTROL JOINTS. 45. EXPANSION JOINTS IN CONCRETE (TYP). SEE DETAIL 31/C11.2. EXPANSION JOINTS SHALL BE SPACED AT 24' MAX. ALIGN DRIVE-THRU CONTROL JOINTS WITH CURB CONTROL JOINTS. 46. RELOCATED CITY OF RENTON LUMINAIRE PER RENTON STD. PLAN 117.1. 47. SEAL COAT AND RESTRIPE ASPHALT WITHIN TEMPORARY CONSTRUCTION EASEMENT AS NECESSARY TO RESTORE AREA TO EXISTING CONDITION OR BETTER. 48. PROPOSED DRIVE-THRU. SEE DETAIL 14/C11.1. 49. PROPOSED CURB CUT. SEE DETAIL 7/C11.4. RECORD SITE PLAN FOR HI K-FIL=A RENTON C C SECTION 18, TWP. 23 N., RGE 5 EAST, W. M. CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON 10' GAS EASEMENT /� a. `, 50 ACCESSIBLE PATH OF TRAVEL NOTE: POWER EASEMENT KC REC. NO. 20130411001089 WALKWAYS ALONG ACCESSIBLE ROUTES OF TRAVEL SHALL BE CONTINUOUSLY KC REC NO. 9410201209 ACCESSIBLE, A MINIMUM 48" IN WIDTH, HAVE A MAXIMUM 1.57. CROSS SLOPE, AND SHALL HAVE RAMPS COMPLYING WITH ADA STANDARDS (SECTION 405) WHERE ° 3 NECESSARY TO CHANGE ELEVATION AT A LONGITUDINAL SLOPE EXCEEDING 5% CONTRACTOR SHALL POTHOLE FOOTING OF 16� 42' (1:20). A CONTINUOUS 36" WIDE DETECTABLE WARNING STRIP MEETING ADA ADJACENT EXISTING BUILDING TO ENSURE IT "E a ISN'T ENCROACHING OVER THE PROPERTY LINE N7�•26 42 "� �' Lp STANDARDS (SECTION 406.8) SHALL BE PLACED WHERE A WALK CROSSES OR `� \ SAWCUT AND REPLACE EXISTING ADJOINS A VEHICULAR WAY AND IS NOT SEPARATED BY A CURB, RAILING, OR 7 4 J ASPHALT AS NE ESS RY FOR WATER , OTHER ELEMENT MEETING ADA STANDARDS. 13 ° PQLA \INSTALLATION. MATCH EXISTING a 3 GRADES AND TRENCH AND PATCH ASPHALT PER CITY OF RENTON STD •. o" .Og •0a 4 . %°. d° \\\ 46 SEA PLAN 110. OFF -SITE IMPROVEMENT NOTE: ° ° \olapoo THE CONTRACTOR SHALL COORDINATE WITH OWNER AND THE CITY OF RENTON FOR 41 15 \ 13 \ Qp�ER '�� PHASING OF OFF -SITE IMPROVEMENTS. / 17 a 0' ` ,SLOPES & UTILITIES EASEMENT ° yea � 15 LP 20110620001119 ° ° / 9 / e. °° °° � � 9SAWCUT A 13 0 4 CONCRETENAS REPLACEASTO EXISTING s 30 18 �° �. ° ° s• INSTALL STORM AND MATCH ° 2� 3 °° a, \ EXISTING PAVEMENT SECTION AND ° ° ° 2 5 ° ' GRADES. ° ��! r : ° 7 ° 2 4 °. °. a _ . °e ° SEWER EASEMENT ° ° C 4 ` \ REC NO. 525359515 8 a °° PARKING AND DRIVE AISLES INFORMATION 0 14 PARKING STALLS: 20 / o O° ' ° ° \ 2 \ COMPACT PARKING STALLS: 13 4 40 ADA PARKING STALLS: 2 11 ° \ ° o ° 49\ TOTAL PARKING STALLS: 35 10' GAS EASEMENT / 0 12 \ ° ` 44 KC REC NO. 20130411001089 41 ° ° POWER EASEMENT ` 4 15 5 4 0 ° 9 a KC REC. NO. 9410201209 0 ° * 45 �� e 13 ss SLOPES & UTILITIES EASEMENT ° KC REC NO. 20110811001003 `�� 2 48 °� ° �� 4 O a� ° °° PROPOSED WATER `. 1 8 ° ° 3 ° ° eEASEMENT \ °° 0 43 ° ° . Qe,° .e. �� a �° e ° y a •..°. ' °' ° 10' GAS EASEMENT a KC REC N0. 20130411001089 , BE REVISED) vv \ G° e 15' X 100' 15 SEWER EASEMENT 4. ® REC NO. 97081 10700 A ` ° \ / o 4 21 o ° 9 � � � e. 42.03' 41 / ° 39 S19°57'04"E \ 19 � 04.48' a / 34 SANITARY SEWER EASEMENT KC REC NO. 9708110701 Y ae � X� 39 16 . 13 0 s 36 - --- e---- 30 ° " 4 12 �Z`C MCP s• PROPOSED WATER TEMPORARY CONSTRUCTION EASEMENT e , EASEMENT 4 �6+ �h ' 6 ADA ACCESSIBLE PATH --'- e ® Know what s below. 8 ° p Call before you dig. 30 1 Dial 811 35 14 n s ri PROPOSED WATER R - 4 0 6 312 -- � ' 30 EASEMENT ', �� ACCESS EASEMENT PER SHORT PLAT IN COMPLIANCE WITH CITY OF RENTON STANDARDS / 5 JENSF ACCESS EASEMENT SAWCUT AND REPLACE EXISTING PER SHORT PLAT ASPHALT AS NECESSARY TO INSTALL Q � WATER LATERAL AND MATCH z EXISTING PAVEMENT SECTION AND GRADES. o P 47671 �Q1_ 01 S T5-7 � \ ON L-51 50. RELOCATED STREET LIGHT. Ba Uqh a use n 7 • • Consulting Engineers, Inc• SURVEYED: RLH DESIGNED: SCALE: In =201 L VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 C I T Y O F o o RECORD SITE P LA N I DATE:2 /19 /2019 FIELDBOOK: JC RENTON FOR PAGE: 18215 72nd Avenue South DRAWN: CMS ONE INCH ' CHICK-FIL-A RENTON DRAWING N0: Kent, WA98032 AS -BUILT PLANS MM 3/15/21 CRJ CHECKED: AEM AT FULL SCALE Planning/Building/Public Works Dept. 375 RAINIER AVE S RENTON, WA 98055 C 7.0 425.251.6222 barghausen.com NO. REVISION BY DATE APPR APPROVED: CRJ IF NOT ONE INCH SCALE ACCORDINGLY STORE NO.. 04249 SHEET: 1 OF: 24