Loading...
HomeMy WebLinkAboutR-406321I I LU 1 PROP LINE, TYP �1 1 TRASH ENCLOSURE 1 ' 1 pE� SEWER ESMT 1 0 PRESERVE AND PROTECT 20" ACER RUBRUM 20" ACER RUBRUM, TO BE REMOVED \0. Know what's below. p Call before you dig. 1 Dial 811 �r• 00 1 TREE RETENTION AND REPLACEMENT PLAN FOR CHICK=FIL=A RENTON SECTION 18, TWP. 23 N., RGE 5 EAST, W. M. CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON V GAS ESMT \ \ \ e \\\ SLOPES & UTIL ESMT \ e , e ° \ 4 00 G \\ FIRE HYDRANT, TYP p0 \ p° \ / \ \ ° ° \ D e .D a '°. 4 \ ° D . e ° ° \\ d D \ V" ° D p .° \ O e ° e •0 e e \ 4 0- O O a • e `\ EXISTING °. D ..'t;,. ♦ ` STREETSCAPE °°• d ' \\ TO REMAIN \ POWER ESMT 00 ° \ ° \\ Y l TEL ♦ \\ WALL PER 4. e. CONDITION #24. •D SEE STRUCT ° PLAN SHEET ° A4/S303 AND 6" DECIDUOUS • ° GRADING PLAN TREE TO BE SHEET C4.0. RETAINED ' D V e . • : D ° • • °• d •, . d \\ 12" ACER o ° ♦ \\, RUBRUM, TO ° ♦ \ BE REMOVED D / / ° °' • ° ' \\\ 6" DECIDUOUS e 6 ' TREE TO BE DRETAINED ' ' �°'•°/ / D ° a POWER ESMT '114� e Nb �e1 V1113 0G �\ 0 M gip / 1 ° 1 1 I d I 1 /� , D D . GAS ESMT ftS' d D SETBACK LINE, TYP 8" ACER RUBRUM, TO BE REMOVED O ACER RUBRUM, TO TO BE REMOVED d� CJ � 60� ' ti0 r Barghausen Consulting Engineers, Inc. 18215 72nd Avenue South Kent, WA 98032 3 425.251.6222 barghausen.com No. RESPONSE TO CITY COMMENTS REVISION TREE REPLACEMENT SCHEDULE TREES BOTANICAL / COMMON NAME ACER CIRCINATUM / VINE MAPLE +* E MULTI -TRUNK SPECIMENS ONLY. CONT. SIZE WATER USE ORIGIN FOLIAGE QTY B & B 6' MIN HT LOW NATIVE DECIDUOUS 2 ACER TRUNCATUM X A. PLAT. 'WARREN RED' / PACIFIC SUNSET MAPLE B & B 2" DBH DECIDUOUS HYBRID DECIDUOUS 1 PINUS CONTORTA / SHORE PINE B & B 6' MIN HT MEDIUM NATIVE EVERGREEN 3 TOTAL: 6 TREES DEPARTMENT OF COMMUNITY i CITY OF AND ECONOMIC DEVELOPMENT Renton TREE RETENTION WORKSHEET Planning Division 1055 South Grady Way -Renton, WA 98057 Phone:425-430-7200 1 www.rentonwa.gov 1. Total number of trees over 6" diameter', or alder or cottonwood trees at least 8" in diameter on project site 5 trees 2. Deductions: Certain trees are excluded from the retention calculation: Trees that are dangerous 0 trees Trees in proposed public streets 0 trees Trees in proposed private access easements/tracts 0 trees Trees in critical areas3 and buffers 0 trees Total number of excluded trees: 0 trees 3. Subtract line 2 from line 1: 5 trees 4. Next, to determine the number of trees that must be retained4, multiply line 3 by: 0.3 in zones RC, R-1, R-4, R-6 or R-8 0.2 in all other residential zones 0.1 in all commercial and industrial zones 1 trees 5. List the number of 6 In diameter, or alder or cottonwood trees over 8" in diameter that you are proposing5 to retain 4: o trees 6. Subtract line 5 from line 4 for trees to be replaced: (if line 6 is zero or less, stop here. No replacement trees are required) 1 trees 7. Multiply line 6 by 12" for number of required replacement inches: 12 inches 8. Proposed size of trees to meet additional planting requirement: (Minimum 2" caliper trees required for replacement, otherwise enter 0) 2 inches per tree 9. Divide line 7 by line 8 for number of replacement trees6: (If remainder is .5 or greater, round up to the next whole number) 6 trees 1 Measured at 4.5' above grade. z A tree certified, in a written report, as dead, terminally diseased, damaged, or otherwise dangerous to persons or property by a licensed landscape architect, or certified arborist, and approved by the City. 3 Critical areas, such as wetlands, streams, floodplains and protected slopes, are defined in RMC 4-3-050. 4 Count only those trees to be retained outside of critical areas and buffers. 5 The City may require modification of the tree retention plan to ensure retention of the maximum number of trees per RMC 4-4-1301-17a. 6 When the required number of protected trees cannot be retained, replacement trees, with at least a two-inch (2") caliper or an evergreen at least six feet (6) tall, shall be planted. See RMC 4-4-130.H.1.e.(ii) for prohibited types of replacement trees. 1 H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\Tree Retention Worksheet.docx 08/2015 SURVEYED: RLH DESIGNED: JLB DRAWN: JLB JLB 11/12/19 JLB CHECKED: JLB BY DATE APPR mPROWm JLB 1. SEE TREE RETENTION REPORT PREPARED BY GREENFOREST, INC., DATED NOVEMBER 1, 2019. 2. TREE REMOVAL RECOMMENDATION DUE TO INSTALLATION OF GAS LINE AND PROPOSED SITE GRADING. Greenforest Incorporated Consulting Arborist MEMORANDUIM TO: Carlos Arias, Project Engineer 4G Development and Consulting, Inc. P.O. Box 270571 San Diego CA 92198 REFERENCE: Arborist Report, BCE #18963 SITE ADDRESS: 361 Rainier Ave., Renton WA DATE: November 1, 2019 PREPARED BY: Favero Greenforest, ISA Certified Arborist # PN -0143A ISA Tree Risk Assessment Qualified ASCA Registered Consulting Arborist® #379 Digitally signed by Favero Greenforest Favero DIN: cn=Favero Greenforest, o, ou, ema i I=g reenforesti nc@m i nd spri ng.com, Greenforest D=Ll5 Date: 2019.11.01 13:06:48-07'00' Your project proposes to remove 3 trees, at the south and east periphery of the site. The reason for the tree removal is that a gas line needs to be installed underneath or within close proximity to the trees. This site also requires excavation that will lower existing grade over the entire site by a depth of 2 feet. The impacted trees include: Tree No. DBH Species 950429 13.6" Red maple 950430 8.3" Red maple 950774 14.1" Red maple It is my opinion that these trees will not survive the required site improvements, and I recommend they be removed. 4547 South Lucile Street, Seattle, WA 98118 Tel. 206-723-0656 R - 406 321 Ado ��E� IN COMPLIANCE WITH CITY OF RENTON STANDARDS O CURRENT PLANNING ftk Matt Herrera 01 /07/2020 %9WQ�� D NOT FOR CONSTRUCTION SCALE: VERTICAL: NAVD 1988 1'I = 20'-011 HORIZONTAL: NAD IW3/1991 Aofthk C 1 T Y OF PRI RENTON ONE INCH AT PULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY v TREE RETENTION AND REPLACEMENT PLAN 0 D FOR CHICK-FIL-A RENTON 375 RAINIER AVE S, RENTON, WA 98055 6.do"_ STORE NO.:04249 11/18/19 L2 2 8