HomeMy WebLinkAboutR-406327co I I LU v J I b M t0 O, ro U, 0 m a J 4 LANDSCAPE IRRIGATION NOTES 1. GENERAL CONTRACTOR AND LANDSCAPE CONTRACTOR TO COORDINATE: A) INSTALLATION OF 110V ELECTRICAL SERVICE FROM ELECTRICAL SOURCE TO AUTOMATIC CONTROLLER, INCLUDING WIRE HOOK-UP INTO MOUNTED CONTROLLER. IRRIGATION CONTRACTOR WILL MOUNT CONTROLLER PER DESIGN AND COORDINATE WITH GENERAL CONTRACTOR. B) INSTALLATION OF IRRIGATION/SERVICE METER AND STUB TO IRRIGATION POINT OF CONNECTION, PER UTILITY PLAN(S). PROVIDE STANDARD THREADED STUB -OUT WITH THREADED CAP ON DISCHARGE SIDE OF METER. STUB -OUT TO BE INSTALLED APPROXIMATELY 18 INCHES BELOW FINISH GRADE. C) VERIFICATION OF STATIC WATER PRESSURE AT POINT -OF -CONNECTION (P.O.C.) CONTRACTOR SHALL NOTIFY OWNER AND BARGHAUSEN CONSULTING ENGINEERS, INC., OF ANY VARIATION IN STATIC PRESSURE OVER 5 PSI GREATER/LESS THAN DESIGN PRESSURE. D) INSTALLATION OF SLEEVING. 2. PROVIDE ALL LABOR, MATERIALS, TRANSPORTATION, AND SERVICES NECESSARY TO FURNISH AND INSTALL A COMPLETE IRRIGATION SYSTEM AS INDICATED ON THE DRAWINGS AND/OR NOTES. PROVIDE A ONE (1) YEAR WARRANTY/GUARANTEE FROM FINAL ACCEPTANCE AGAINST ALL DEFECTS IN MATERIALS, EQUIPMENT, AND WORKMANSHIP. 3. COORDINATE IRRIGATION INSTALLATION WITH GENERAL CONTRACTOR, ELECTRICAL CONTRACTOR, LANDSCAPE CONTRACTOR, OWNER, ARCHITECT, AND LANDSCAPE ARCHITECT. 4. LANDSCAPE CONTRACTOR TO TEST AVAILABLE WATER PRESSURE PRIOR TO BEGINNING ANY WORK. PROVIDE LANDSCAPE ARCHITECT WITH WRITTEN PSI RESULTS. 5. ALL WORK PER LOCAL CODE. INSTALLATION PER MANUFACTURER'S WRITTEN SPECIFICATIONS. 6. CONTRACTOR TO OBTAIN AND PAY FOR ALL PERMITS, FEES, AND REQUIRED CITY INSPECTIONS. 7. SUBMITTALS: A) SUBMIT FIVE (5) COPIES OF EACH ITEM LISTED BELOW FOR LANDSCAPE ARCHITECT'S REVIEW AND APPROVAL, B) PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED, C) CONTROL WIRING PATH DIAGRAM, D) "AS -BUILT" DRAWINGS. E) OPERATION AND MAINTENANCE MANUALS. 8. PROVIDE AND KEEP UP TO DATE A COMPLETE "AS -BUILT" RECORD SET OF PRINTS WHICH ARE TO BE CORRECTED DAILY AND SHOW EVERY CHANGE FROM THE ORIGINAL DRAWINGS AND NOTES AND EXACT "AS -BUILT" LOCATIONS, SIZES AND KIND OF EQUIPMENT. THIS SET OF DRAWINGS. ARE TO BE KEPT ON SITE AND ARE TO BE USED ONLY AS THE RECORD SET. ALL WORK IS TO BE NEAT AND LEGIBLE ANNOTATIONS THEREON DAILY AS THE WORK PROCEEDS, SHOWING WORK AS ACTUALLY INSTALLED. DIMENSION FORM TWO (2) PERMANENT POINTS OF REFERENCE, BUILDING CORNERS, WALKS, OR ROAD INTERSECTIONS, ETC., THE LOCATION OF THE FOLLOWING: A) CONNECTION TO WATER LINES (P.O.C.), B) CONNECTIONS TO ELECTRICAL POWER, C) GATE VALVE, QUICK COUPLERS, AND REMOTE CONTROL VALVE, D) ROUTING OF MAINLINE (DIMENSION MAXIMUM 100' ALONG ROUTING), E) ROUTING OF CONTROL WIRING, F) OTHER RELATED EQUIPMENT AS DIRECTED BY THE LANDSCAPE ARCHITECT. FINISH GRADE cs TH SUB GRADE JLL F Lr%ivJ I Ul. 1 c7chline® CV DRIPLINE SPACING NETAFIMT" TECHLINE® CV SUBGRADE INSTALLATION NOT TO SCALE p Know what's below. p Call before you dig. 1 Dial 811 IRRIGATION NOTES AND DETAILS FOR CH1CK=FIL=A RENTON SECTION 18, TWP. 23 N., RGE 5 EAST, W. M. CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON 9. PREPARE AND PROVIDE PRIOR TO COMPLETION OF CONSTRUCTION, A THREE RING BINDER CONTAINING THE FOLLOWING INFORMATION: A) INDEX SHEET STATING CONTRACTOR'S ADDRESS, TELEPHONE NUMBER, FAX, E-MAIL AND A, LIST OF EQUIPMENT WITH NAME AND ADDRESS OF LOCAL MANUFACTURER'S REPRESENTATIVES, B) CATALOG AND PARTS SHEETS ON EVERY MATERIAL AND EQUIPMENT INSTALLED UNDER THIS, CONTRACT, C) GUARANTEE STATEMENT, D) COMPLETE OPERATING AND MAINTENANCE INSTRUCTIONS ON ALL MAJOR EQUIPMENT. E) CONSTRUCTION DETAILS FROM THE PROJECT, F) COMPLETE TROUBLE -SHOOTING GUIDE TO COMMON IRRIGATION PROBLEMS, G) WINTERIZATION AND SPRING START-UP PROCEDURES, H) CHART OF APPROXIMATE WATERING TIMES FOR SPRING, SUMMER, AND FALL, 1) A COPY OF THE "AS -BUILT" DRAWINGS AND CONTROLLER CHART. 10. ALL VALVES TO BE PLACED IN "CARSON" GRADE LEVEL BOXES WITH BOLT -LOCK LIDS (OR APPROVED EQUIVALENT). SET BOXES 2 INCHES HIGHER THAN FINISH GRADE IN MULCH AREAS AND FLUSH WITH FINISH GRADE IN LAWN AREAS. JUMBO BOX FOR CHECK VALVE, 10" ROUND BOX FOR GATE/QUICK COUPLER/WIRE SPLICES, AND 12" STANDARD FOR CONTROL VALVES. PROVIDE BOX EXTENSIONS AS REQUIRED. 11, MAINLINE PIPE TO BE BURIED 18 INCHES, LATERALS 12 INCHES, AND SLEEVES 24" INCHES BELOW FINISH GRADE. NO ROCK OR DEBRIS TO BE BACKFILLED OVER PIPE. 12. HEAD AND LINE POSITIONING IS DIAGRAMMATIC ON PLAN. ADJUST IN FIELD AS NECESSARY FOR 100 PERCENT COVERAGE. VALVES TO BE POSITIONED ADJACENT TO PAVEMENT/CURBS, IN SHRUB BEDS WHERE POSSIBLE. 13, FAMILIARIZE OWNERS FACILITY OPERATOR WITH IRRIGATION SYSTEM FUNCTION, CONTROLLER PROGRAMMING, SYSTEM OPERATION AND MAINTENANCE REQUIREMENTS. 14. SPRINKLERS ON RISERS WILL NOT BE ALLOWED UNLESS NOTED ON PLANS. 15, RADIUS REDUCTION TO BE MADE BY USE OF PRESSURE ADJUSTMENT, SCREENS, AND/OR ALTERNATE NOZZLES. IN -NOZZLE ADJUSTMENT IS LIMITED TO 10 PERCENT FOR SPRAY HEADS AND PER MANUFACTURER'S LIMITS FOR OTHER SPRINKLERS. SPRINKLER SPACING NOT EXCEED 60% OF THE DIAMETER OF THE PUBLISHED DATA. 16. ALL CONTROL WIRE SPLICES TO BE MADE AT VALVE BOXES WITH WATER TIGHT ELECTRICAL SPLICES, 3M, SCOTT'S LOCK SEAL TACK 3576-78, OR EQUIVALENT. 17. EACH VALVE BOX TO CONTAIN A MINIMUM OF TWO (2) SPARE ORANGE CONTROL WIRES FOR JACKETED WIRE. ROUTE SPARE WIRES FROM THE CONTROLLER TO THE LAST VALVE OF EACH MAINLINE BRANCH. COMMON WIRE TO BE WHITE. SINGLE STRAND WIRE TO BE A MINIMUM OF 14 GAUGE. 18. ALL ELECTRICAL EQUIPMENT TO BE U.L. TESTED AND APPROVED, AND BEAR THE U.L. LABEL. 19. CROSS CONNECTION PROTECTION INSPECTION REQUIRED. THE BACKFLOW DEVICE TO BE TESTED UPON THE ORIGINAL INSTALLATION. THE TESTING TO BE PERFORMED BY A PERSON HOLDING A CURRENT CERTIFICATE AS A BACKFLOW TESTER. THE TEST REPORT TO BE SUBMITTED TO THE LOCAL WATER DISTRICT, OR PURVEYOR, AND OWNER WITH A COPY TO BARGHAUSEN CONSULTING ENGINEERS, INC. CONTRACTOR TO INCLUDE TESTING IN THE SCOPE OF WORK. OWNER IS RESPONSIBLE FOR ANNUAL INSPECTIONS AFTER THE INTIAL INSPECTION. 20. CONTRACTOR TO PROVIDE SYSTEM WINTERIZATION/SPRING SERVICE WHEN INSTALLATION HAS BEEN COMPLETED WITHIN 90 DAYS OF NOVEMBER 1 FOR WINTERIZATION, OR MAY 15 FOR SPRING SERVICE. SERVICE TO BE PERFORMED AS NEAR AS PRACTICAL TO THE ABOVE DATES, OR AS FREEZE/PRECIPITATION CONDITIONS DETERMINE SERVICE NEED. MANUAL FLUSH VALVE PLUMBED TO PVC OR POLY Techline® CV DRIPLINE Techline® START CONNECTION MALE ADAPTER EXHAUST HEADER Techline® TEE REMOTE CONTROL VALVE WITH DISC FILTER AND PRV AREA PERIMETER SUPPLY HEADER NETAFIM" TECHLINE® CV IRREGULAR AREAS: TRIANGULAR NOT TO SCALE Barghausen Consulting Engineers, Inc. 18215 72nd Avenue South Kent, WA 98032 r425.251.6222 barghausen.com RESPONSE TO CITY COMMENTS REVISION NOTE MOUNT CONTROLLER LCD SCREEN AT EYE LEVEL, CONTROLLER SHALL BE HARD -WIRED TO GROUNDED 110 VAC POWER SOURCE. PER SPEC FRONT ELEVATION RIGHT ELEVATION LEGEND U IRRIGATION PER SPEC CONTROLLER (ACC) 00, PER PLAN O IRRIGATION CONTROL WIRE IN 0 CONDUIT. SIZE AND TYPE PER LOCAL CODES 4) ELECTRICAL SUPPLY CONDUIT. CONNECT TO POWER SOURCE, J-BOX INSIDE CONTROLLER ® ADJACENT SURFACE TO MOUNT IL CONTROLLER PER PLAN IRRIGATION CONTROLLER - WALL MOUNT NOT TO SCALE FINISH GRAC`_ REMOTE CON VALVE PVC MAINLY VALVE BOX F_ FLUSH WITH LAWN (1 "), AND MULCH (3„) PRESSURE REGULATOR PVC LATERAL SCH. 80 UNION VALVE BOX EXTENSION AS REQUIRED BRICK SUPPORTS C.F. 7/8" WASHED GRAVEL SUMP CONTROL VALVE, PRESSURE REGULATOR, AND FILTER NOT TO SCALE THREADED BALL VALVE SCH 80 PVC MALE ADAPTER FINISH GRADE SCH 40 PVC 45' ELBOW FOUR (4) 4%8" BRICKS- NOTE: 1. LOCATE VALVE BOXES IN PLANTING AREAS. 2. WRAP VALVE BOX WITH A MINIMUM OF 3 MIL THICK PLASTIC AND SECURE IT USING DUCT TAPE OR ELECTRICAL TAPE. 3. ALL THREADED CONNECTIONS TO BE MADE USING TEFLON TAPE. 4. ALL CHANGES IN ELEVATION SHALL BE MADE USING SCH 40 PVC 45' ELBOWS. BALL VALVE NOT TO SCALE SURAYED. RLH DESIGNED` JLB DRAWN` JLB JLB 11/12/19 JLB CHECKED: JLB BY DATE APPR &-Rmm JLB SCALE: H ZONNTA�L:+q IN3/1i,99, N/A ONE INCH AT PULL SCALE IF NOT ONE INCH SCALE ACCOMNGLY REGULAR VALVE BOX WITH LOCKING LID PAVEMENT a. VSCH 80 PVC UNION SxS SCH 80 PVC NIPPLE TxS MAINLINE THREE INCH (Y) THICK LAYER OF PEA GRAVEL OR APPROVED EQUAL 3/8" WELDED WIRE MESH PER MANUFACTURER'S NOTE 1. THIS DETAIL TO BE USED IF HUNTER XC-HYBRID IRRIGATION CONTROLLER IS USED FOR THIS PROJECT. 2. MOUNT ON WEATHER EXPOSED WALL 8' ABOVE GRADE RAIN SENSOR NOT TO SCALE VALVE BOX WITH COVER FINISH GRADE QUICK COUPLING VALVE CENTER IN BOX 1 C.U. FT. 7/8" GRAVEL SUMP MARLEX ELL - TYPICAL PVC SCH 80 PVC NIPPLE PVC SCH 40 PVC SXSXT TEE QUICK COUPLING VALVE ASSEMBLY NOT TO SCALE of wasy��=4 m • � . • � . � . � � , ■N'T Y 0 D NOT FOR CONSTRUCTION %R CITY OF RENTON Plonning/Building/Public Works Dept. v IRRIGATION NOTES AND DETAILS 0 D FOR CHICK-FIL-A RENTON 375 RAINIER AVE S, RENTON, WA 98055 6.AWA_ STORE NO.:04249 'KET NSOR :R'S )NS 11/18/19