Loading...
HomeMy WebLinkAboutP_Permit_Set_Plans_22x34_Kaiwi_Addition_20220328_v1VICINITY MAP UNION AVE SEPROJECT LOCATION: 4114 NE 2ND ST, RENTON NE 2ND ST NE 4TH ST 0 10 5 20 20' FRONT YARD EXISTING 2-STORY FRAME HOUSE #4114 EXISTING HOUSE #4120 410' PARCEL 1079350030 R.O.W. PUBLIC STREET NE 2ND ST AREA OF PROPOSED WORK 88° 14' 29"N W 60.00'125.54'60.00'15' - 0"4' - 0" 4' - 0"20' - 0"20' - 0"15' REAR YARD 4' SIDE YARD4' SIDE YARDEXISTING HOUSE #4108 410'PARCEL 1079350020 PARCEL 1079350040 PARCEL 5182100077 PARCEL 5182100078 CL CONC. SIDEWALK 17 ' - 0 " (E) CONC. DRIVEWAY(E)PAVED WALK(E) BRICK WALL (E) CHIMNEY (E) SHED (E)CONC. WALKPROPOSED NEW ADDITION (E) CONC. PATIO (E) MULCH PLAYGROUND 125.51'(E) OPEN FRONT PORCH (E)STONE WALK(E) CONC. PATIO TO BE REMOVED 22' - 0"22' - 0"5' - 3" (N) COVERED CONC. PATIO DATE: SHEET SIZE: DRAWING: 22" x 34"ENGINEERED STRUCTURESGLOBAL DESIGN, PLLCDRAWINGS PROVIDED BY: !" # $%&’()%*)&%+,2-$-2 1/26/2022 2:07:40 PMSPSITE PLAN2/6/2022KAIWI ADDITION4114 NE 2ND ST,RENTON, WA 98059•A COPY OF THE APPROVED PLAN MUST BE ON SITE WHENEVER CONSTRUCTION IS IN PROGRESS. •PAVED SURFACES INCLUDING ROADWAYS, SIDEWALKS, AND CURBS THAT ARE DAMAGED BY NEW CONSTRUCTION SHALL BE REPAIRED AS REQUIRED BY THE STREET USE INSPECTOR. •ALL LOCATIONS OF EXISTING UTILITIES SHOWN HEREIN HAVE BEEN OBTAINED FROM AVAILABLE COUNTY RECORDS AND SHOULD BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE OR ACCURATE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREIN WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. •THE CONTRACTOR SHALL LOCATE AND PROTECT ALL CASTINGS AND UTILITIES DURING CONSTRUCTION AND SHALL CONTACT THE UNDERGROUND UTILITIES LOCATOR SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. •ALL WORK PERFORMED BY PUBLIC UTILITY ENTITIES TO REMOVE OR RELOCATE EXISTING UTILITIES SHALL BE DONE AT THE PERMITEE'S EXPENSE. •UTILITY SERVICE CONNECTIONS SHOWN ON SITE PLAN ARE TO BE MAINTAINED PRIVATELY. •ALL CLEARING AND GRADING MUST BE IN ACCORDANCE WITH LOCAL JURISDICTION CLEARING AND GRADING EROSION CONTROL STANDARDS, DEVELOPMENT STANDARDS, LAND USE CODE, UNIFORM BUILDING CODE, PERMIT CONDITIONS, AND ALL OTHER APPLICABLE CODES, ORDINANCES AND STANDARDS. •THE CONTRACTOR SHALL PROVIDE AND MAINTAIN TEMPORARY EROSION AND SEDIMENTATION CONTROL FACILITIES TO INSURE THAT SEDIMENT-LADEN WATER DOESN'T ENTER THE NATURAL OR PUBLIC DRAINAGE SYSTEM. AS CONSTRUCTION PROGRESSES AND UNEXPECTED (SEASONAL) CONDITIONS DICTATE, MORE SILTATION CONTROL FACILITIES MAY BE REQUIRED TO INSURE COMPLETE SILTATION COLLECTION ON THE PROJECT. DURING THE COURSE OF CONSTRUCTION IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY WORKSITE ACTIVITY AND TO PROVIDE ADDITIONAL FACILITIES THAT MAY BE NEEDED TO PROTECT ADJACENT PROPERTIES. •THE CONTRACTOR SHALL KEEP OFF-SITE STREETS CLEAN AT ALL TIMES BY SWEEPING. WASHING OF THESE STREETS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL FROM CITY OR COUNTY OFFICIALS. •FINAL SITE DRAINAGE MUST DIRECT DRAINAGE AWAY FROM ALL BUILDING STRUCTURES AT A MINIMUM SLOPE OF 6 INCHES WITHIN THE FIRST 10 FEET. (IRC R401.3). GENERAL SITE PLAN NOTES CONSTRUCTION OF A NEW ONE STORY ADDITION TO THE EXISTING SINGLE FAMILY RESIDENCE. PROJECT DESCRIPTION ZONING DATA 1" = 10'-0" SITE PLAN PROJECT ADDRESS: 4114 NE 2ND ST, RENTON, WA 98059 PARCEL NO. 1079350030 ZONING CODE: RENTON MUNICIPAL CODE -TITLE IV ZONE: R-10 GROSS LOT AREA: 7,531 sq. ft. MAX. ALLOWED LOT COVERAGE BY STRUCTURES: 55% * 7,531 sq. ft. = 4,142 sq. ft. EXISTING LOT COVERAGE BY STRUCTURES: EXISTING HOUSE -1,250 sq. ft. TOTAL EXISTING LOT COVERAGE BY STRUCTURES -1,250 sq. ft. PROPOSED LOT COVERAGE BY STRUCTURES: EXISTING HOUSE -1,250 sq. ft. NEW ADDITION -476 sq. ft. TOTAL PROPOSED LOT COVERAGE BY STRUCTURES -1,726 sq. ft. MAX. ALLOWED LOT IMPERVIOUS SURFACE: 70% * 7,531 sq. ft. = 5,272 sq. ft. EXISTING LOT IMPERVIOUS SURFACE AREA: EXISTING HOUSE -1,250 sq. ft. EXISTING SHED - 66 sq. ft. 199 sq. ft. EXISTING CONCRETE DRIVEWAY -395 sq. ft. EXISTING CONCRETE PATIOS, PORCHES AND WALKS -969 sq. ft. TOTAL EXISTING LOT IMPERVIOUS SURFACE -2,680 sq. ft. PROPOSED LOT IMPERVIOUS SURFACE AREA: EXISTING HOUSE -1,250 sq. ft. EXISTING SHED -66 sq. ft. EXISTING CONCRETE DRIVEWAY -395 sq. ft. NEW ADDITION -476 sq. ft. NEW COVERED PATIO -264 sq. ft. EXISTING CONCRETE PATIO, PORCH AND WALKS TO REMAIN -617 sq. ft. TOTAL PROPOSED LOT IMPERVIOUS SURFACE -3,068 sq. ft. MINIMUM SETBACKS OF STRUCTURE: FRONT YARD -20' REAR YARD -15' SIDE YARDS -4'OWNER: ALIKA KAIWI alika.jenny@yahoo.com CONTACT INFORMATION DESIGN PROFESSIONAL: ENGINEERED STRUCTURES GLOBAL DESIGN, PLLC www.esg-design.com 206-890-5949 engineer@esg-design.com 2,813 sq. ft. 199 sq. ft. 705 sq. ft. 3,025 sq. ft. DATE: SHEET SIZE: DRAWING: 22" x 34"ENGINEERED STRUCTURESGLOBAL DESIGN, PLLCDRAWINGS PROVIDED BY: !" # $%&’()%*)&%+,2-$-2 1/26/2022 6:42:06 PMA0.1GENERAL NOTES2/6/2022KAIWI ADDITION4114 NE 2ND ST,RENTON, WA 98059OWNER: ALIKA KAIWI alika.jenny@yahoo.com CONTACT INFORMATION DESIGN PROFESSIONAL: ENGINEERED STRUCTURES GLOBAL DESIGN, PLLC www.esg-design.com 206-890-5949 engineer@esg-design.com PROJECT/CODE SUMMARY ALL WORK TO COMPLETED IN COMPLIANCE WITH THE NEWEST VERSION OF THE FOLLOWING CODES AND REGULATIONS AS REQ'D 2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL FIRE CODE PROJECT INFORMATION ADDRESS 4114 NE 2ND ST, RENTON, WA 98059 ZONING R-10 GENERAL RESIDENTIAL PROJECT NOTES ANY SPECIFIC REFERENCE TO CODES, RULES, REGULATIONS, STANDARDS, MANUFACTURER'S INSTRUCTIONS OR REQUIREMENTS OF REGULATORY AGENCIES SHALL MEAN THE LATEST PRINTED EDITION OF EACH IS IN EFFECT AT THE DATE OF SUBMISSION OR BID UNLESS THE DOCUMENT IS SHOWN DATED. FIRE PROTECTION: •ALL NEW DETECTORS TO BE COMBINATION SMOKE AND CARBON MONOXIDE DETECTORS. (IRC R314) •ALL NEW DETECTORS TO BE HARD-WIRED WITH BATTERY BACK-UP. (IRC R314) •DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE APPROVED MANUFACTURER'S INSTRUCTION AND IN ACCORDANCE WITH UL217 AND NFPA 72. •DETECTORS SHALL BE INTERCONNECTED SUCH THAT WHEN ONE ALARM IS ACTIVATED ALL REMAINING ALARMS ARE ACTIVATED. •IN WOOD-FRAMED CONSTRUCTION, FIREBLOCKING SHALL BE PROVIDED IN LOCATIONS PER IRC R302.11. •WHERE THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR-CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET (IRC R302.12). WINDOWS / DOORS: •IN EACH SLEEPING ROOM AN EGRESS WINDOW OR DOOR SHALL BE PROVIDED THAT HAS 5.7 SF. OF CLEAR NET OPERABLE AREA. THE SMALLEST CLEAR MIN. DIMENSION SHALL NOT BE LESS THAN 20" IN WIDTH OR 24" IN HEIGHT. WINDOW SILLS IN SLEEPING ROOMS NOT TO EXCEED 44"ABOVE THE FINISH FLOOR.(IRC R310) •20 MIN., SELF-CLOSING DOOR W/ WEATHER STRIPPING REQUIRED AT GARAGE ENTRANCE TO LIVING SPACE. (IRC R302.5.1) •WINDOWS WITHIN 24" OF THE FLOOR SHALL NOT PERMIT OPENINGS THAT ALLOW PASSAGE OF 4" DIAMETER SPHERE. (IRC R312.2.1) •WINDOW AND DOOR HEADERS SHALL BE INSULATED WITH A MINIMUM OF R-10 INSULATION ( WSEC R402.1.1) •EVERY EXTERIOR EXIT DOOR SHALL HAVE A LANDING ON EACH SIDE. MAXIMUM STEP AT THRESHOLD SHALL BE 1-1/2". (IRC R311.3) •CAULKING & SEALANTS: EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES; OPENINGS BETWEEN WALLS AND FOUNDATION; OPENINGS BETWEEN ROOF AND WALL PANELS, OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOORS & ROOFS; AND ALL OTHER OPENINGS IN THE EXTERIOR BUILDING ENVELOPE SHALL BE SEALED, CAULKED, GASKETED OR WEATHERSTRIPPED. (IRC R702.7 & R703) GLAZING: •WINDOW SCHEDULE IS FOR PLANNING PURPOSES ONLY. GC TO VERIFY LOCATIONS, ROUGH OPENINGS, SWING DIRECTIONS AND LAMINATION / TEMPERING REQUIREMENTS PRIOR TO FABRICATION. GC TO REVIEW AND CONFIRM ALL OPERATIONAL DETAILS WITH HOMEOWNER PRIOR TO ORDERING. PROCEEDING WITH WINDOW/DOOR ORDER PRIOR RECEIVING APPROVAL FROM HOMEOWNER IS AT THE SOLE RISK OF THE GENERAL CONTRACTOR. •U-FACTORS OF FENESTRATION PRODUCTS (WINDOWS, DOORS AND SKYLIGHTS) SHALL BE DETERMINED IN ACCORDANCE WITH NFRC 100 BY AN ACCREDITED, INDEPENDENT LABORATORY, AND LABELED AND CERTIFIED BY THE MANUFACTURER. •PROVIDE LAMINATED / TEMPERED GLAZING PER CODE AT THE FOLLOWING LOCATIONS (IRC R308.4) -WINDOWS/SIDELIGHTS WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24" ARC OF THE DOOR AND WHOSE BOTTOM EDGE IS LESS THAN 60" ABOVE THE NEAREST WALKING SURFACE -GLAZING THAT IS 18" OR LESS ABOVE ADJACENT WALKING S URFACE -SLOPED GLAZING ACTING AS SKYLIGHTS -ALL OTHER HAZARDOUS LOCATIONS AS REQUIRED BY APPLICABLE CODES STAIRS AND HANDRAILS: •MINIMUM STAIRWAY REQUIREMENTS ARE AS FOLLOWS: 36" MIN. WIDTH, 6'-8" MIN. HEADROOM, 7-3/4" MAX. RISE AND 10" MIN. TREAD DEPTH. (IRC R311.7) •LANDING SHALL BE PROVIDED AT TOP AND BOTTOM OF EACH STAIRWAY. LANDING DEPTH IN THE DIRECTION OF TRAVEL SHALL BE MIN. 36 INCHES, LANDING WIDTH TO BE NOT LESS THAN STAIRWAY WIDTH. (IRC R311.7.6) •PROVIDE A HANDRAIL 34"-38" A.F.F. HAND GRIP PORTION TO BE CONTINUOUS AND 1-1/4" TO 2" IN CROSS SECTION WITH BOTH ENDS RETAINED. THERE SHALL BE A SPACE OF NOT LESS THAN 1-1/2" BETWEEN THE WALL AND THE HANDRAIL. (IRC R311.7.8) GUARDRAILS: •GUARDS SHALL BE LOCATED ALONG OPEN-SIDED WALKING SURFACES, INCLUDING STAIRS, RAMPS AND LANDINGS, THAT ARE LOCATED MORE THAN 30 INCHES VERTICALLY TO THE FLOOR OR GRADE BELOW. (IRC R312.1.1) •REQUIRED GUARDRAILS SHALL BE NOT LESS THAN 36 INCHES IN HEIGHT AND SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER (TRIANGULAR OPENINGS AT THE OPEN SIDE OF STAIRS SHALL NOT ALLOW PASSAGE OF A SPHERE 6 INCHES DIAMETER). (IRC R312.1.3) •ATTACH BASE OF GUARDRAIL POSTS TO FRAMING TO SUPPORT 200# LATERAL LOAD. SEE STRUCTURAL FOR DETAILS. CEILING HEIGHTS: •HABITABLE SPACE, HALLWAYS, BATHROOMS, TOILET ROOMS, LAUNDRY ROOMS, AND PORTIONS OF BASEMENTS CONTAINING THESE SPACES SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN 7 FEET. THE REQUIRED HEIGHT SHALL BE MEASURED FROM THE FINISH FLOOR TO THE LOWEST PROJECTION FROM THE CEILING.(IRC R305.1) •FOR ROOMS WITH SLOPED CEILINGS, AT LEAST 50 PERCENT OF THE REQUIRED FLOOR AREA OF THE ROOM SHALL HAVE A CEILING HEIGHT OF AT LEAST 7 FEET AND NO PORTION OF THE REQUIRED FLOOR AREA MAY HAVE A CEILING HEIGHT OF LESS THAN 5 FEET. (IRC R305.1) •ATTIC AREAS WITH A VERTICAL HEIGHT OF 30 INCHES OR GREATER SHALL HAVE A ACCESS OPENING NOT LESS THAN 22 INCHES BY 30 INCHES. WHERE LOCATED IN A WALL, THE OPENING SHALL BE NOT LESS THAN 22 INCHES WIDE BY 30 INCHES HIGH. (IRC R807.1) CRAWL SPACES: •CRAWL SPACE ACCESS SHALL BE PROVIDED TO ALL UNDER-FLOOR SPACES. ACCESS OPENINGS SHALL BE A MINIMUM OF 18 x 24 INCHES, OPENINGS THROUGH A WALL SHALL BE 16 x 24 INCHES. (IRC R408.4) •PROVIDE MINIMUM 18 INCH CRAWL SPACE UNDER WOOD JOISTS AND 12 INCHES UNDER WOOD GIRDERS (IRC R317.1) •CRAWL SPACE VENTILATION, MINIMUM NET AREA SHALL BE OF 1 SQUARE FOOT FOR EACH 150 SQUARE FEET OF UNDERFLOOR AREA (EXCEPT SPACE OCCUPIED BY A BASEMENT) (1,500 SQUARE FEET WITH CLASS 1 VAPOR RETARDER). AT LEAST ONE OPENING SHALL BE LOCATED WITHIN THREE FEET OF EACH CORNER AND ARRANGED TO PROVIDE CROSS VENTILATION ON AT LEAST TWO OPPOSITE SIDES. OPENING TO BE COVERED WITH APPROVED SCREENING MATERIAL. (IRC R408.2) •A GROUND COVER VAPOR BARRIER OF MIN. 6 MIL. (0.006") POLYETHYLENE (0R EQUIVALENT)SHALL BE INSTALLED IN ALL CRAWL SPACES, JOINTS LAPPED 12", EXTEND UP FOUNDATION WALL AND SECURE TO SILL PLATE WHEREVER PRACTICAL. (IRC R408.1) FOUNDATION DRAINAGE: •CONTRACTOR SHALL PROVIDE AND INSTALL RIGID 4" DIAMETER PERFORATED PVC DRAIN PIPING AROUND THE EXTERIOR AND/OR UPHILL SIDE OF ALL STRUCTURAL FOUNDATION WALLS SHOWN IN THE PROJECT. DRAIN PIPING SHALL BE LOCATED AT A SUITABLE ELEVATION AT OR NEAR THE BASE OF ALL FOUNDATION WALL FOOTINGS. DRAIN PIPES SHALL BE COVERED WITH MINIMUM 12" x 12" LAYER OF 3/4" WASHED DRAIN ROCK, AND WRAPPED WITH A LAYER OF CONSTRUCTION SILT FABRIC. CONTRACTOR IS RESPONSIBLE FOR CONNECTION OF FOUNDATION DRAINS INTO A SUITABLE STORM DRAINAGE SYSTEM OR OTHER APPROVED DRAINAGE DISCHARGE BMP SYSTEM. PROVIDE CLEAN-OUT STANDPIPES AT APPROPRIATE LOCATIONS TO EFFECTIVELY SERVICE THE SYSTEM. PARCELL 1079350030 LOT SIZE 7,531 sq. ft. 2018 UNIFORM PLUMBING CODE 2018 WASHINGTON STATE ENERGY CODE 2020 NATIONAL ELECTRIC CODE GENERAL CONSTRUCTION PLAN NOTES 1. GENERAL CONTRACTOR TO REVIEW ALL DOCUMENTS AND VERIFY ALL DIMENSIONS AND FIELD CONDITIONS AND CONFIRM THAT WORK IS BUILDABLE AS SHOWN IN DRAWINGS. ANY CONFLICTS OR OMISSIONS SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER FOR CLARIFICATION PRIOR TO PROCEEDING WITH WORK IN QUESTION OR ORDERING MATERIALS FOR WORK. COMMENCEMENT OF WORK SHALL BE DEEMED AS THE GC'S ACKNOWLEDGMENT OF ALL WORK TO COMPLETE PROJECT IN CONFORMANCE WITH CONTRACT DOCUMENTS AND SCHEDULE. 2. JOB SITE SHALL BE KEPT CLEAN AND SAFE DURING ALL PHASES OF CONSTRUCTION. 3. WORK AREAS TO REMAIN SECURE AND LOCKABLE DURING CONSTRUCTION. THE GENERAL CONTRACTOR SHALL COORDINATE WITH OWNER TO ENSURE SECURITY. 4. PROTECT BUILDING FROM WATER DAMAGE DURING ALL PHASES OF CONSTRUCTION 5. GENERAL CONTRACTOR SHALL NOTIFY THE HOMEOWNER OF ANY UTILITIES, NOT COVERED IN THE CONSTRUCTION/ DEMOLITION DOCUMENTS, WHICH MAY INTERFERE WITH COMPLETING THE WORK. WHEN REMOVAL IS APPROVED BY THE HOMEOWNER, GENERAL CONTRACTOR SHALL INSPECT, TEST, AND DISCONNECT THE SPECIFIED UTILITY, CUT BACK TO SOURCE AND CAP. 6. DO NOT SCALE DRAWINGS. DOOR AND WINDOW LOCATIONS SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, NOTIFY ENGINEER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION. 7. VERIFY AND COORDINATE DIMENSIONS AND ORIENTATION ON PLANS AND ELEVATIONS. 8. ALL NEW EXTERIOR WALLS TO BE 2x6 FRAMING U.N.O. 9. ALL NEW INTERIOR WALLS TO BE 2x4 FRAMING U.N.O. 10. ALL DIMENSIONS MARKED "CLEAR" OR "CLR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESS OF ALL FINISHES INCLUDING FLOOR FINISHES. 11. DIMENSIONS SHOWN AS "VIF" OF "FIELD VERIFY" SHALL BE VERIFIED BY THE CONTRACTOR IN THE FIELD. CONTRACTOR SHALL NOTIFY ENGINEER OF ANY DISCREPANCY IN DIMENSIONS PRIOR TO PROCEEDING WITH THE WORK IN THAT AREA. 12. "ALIGN" SHALL MEAN ACCURATELY LOCATE FINISH FACES IN THE SAME PLANE. 13. "TYPICAL" OR "TYP" SHALL MEAN THAT THE CONDITION IS REPRESENTATIVE FOR SIMILAR CONDITIONS THROUGHOUT, UNLESS OTHERWISE NOTED. DETAILS ARE USUALLY KEYED AND NOTED "TYP" ONLY ONCE, WHEN THEY FIRST OCCUR. 14. "SIMILAR" OR "SIM" MEANS COMPARABLE CHARACTERISTICS FOR THE CONDITIONS NOTED. 15. GENERAL CONTRACTOR SHALL COORDINATE AND PROVIDE BACKING FOR MILLWORK AND ITEMS ATTACHED OR MOUNTED TO WALLS OR CEILINGS. 16. UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4", UNLESS OTHERWISE NOTED. 17. ALL MECHANICAL AND ELECTRICAL SCOPE OF WORK IS DESIGN/BUILD BY RESPECTIVE SUBCONTRACTORS. FIXTURE, GRILLE, SWITCH, AND OUTLET LOCATIONS SHOULD BE CONSIDERED DURING FRAMING -AND FINAL LOCATIONS SHOULD BE APPROVED BY HOMEOWNER PRIOR TO INSTALLATION. 18. THE GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR COORDINATION OF THE LOCATIONS AND INSTALLATION OF ALL MECHANCIAL, ELECTRICAL, PLUMBING, AND OTHER SUBCONTRACTOR WORK AS NECESSARY FOR THE PROJECT. 19. FOR REMODEL OR ADDITION PROJECTS, IF THE CONTRACTOR UNCOVERE S EXISTING STRUCTURAL CONDITIONS WHICH DO NOT MATCH THE CONSTRUCTION PLANS, OR IF THE CONTRACTOR BELIEVES THE EXISTING CONDITIONS TO BE STRUTURALLY UN-SOUND, THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF THE OBSERVED CONDITION AND REQUEST FURTHER DIRECTION BEFORE PROCEEDING. INTERPRETATIONS: •THESE DOCUMENTS ARE IN PART DIAGRAMMATIC AND SUBJECT TO INTERPRE TATION.THEY DO NOT NECESSARILY SHOW COMPLETE DETAILS OF CONSTRUCTION, WORK, OR MATERIALS, PERFORMANCE OR INSTALLATION, AND DO NOT NECESSARILY SHOW HOW CONSTRUCTION DETAILS OF OTHER ITEMS OF THE WORK MAY AFFECT ANY PARTICULAR INSTALLATION. ALL ASPECTS OF THE PROJECT MUST BE ASCERTAINED BY THE CONTRACTOR AND CORRELATED TO BRING THE PARTS TOGETHER AS A COMPLETED WHOLE. •ANY DETAIL, DIMENSION, OR STATEMENT NOT COMPLETELY CLEAR TO THE CONTRACTOR SHALL BE REFERRED TO THE ENGINEER FOR INTERPRETATION. CONTRACTOR IS REQUESTED TO PROVIDE CONSTRUCTION QUESTIONS IN THE FORM OF A DOCUMENTED "RFI" (REQUEST FOR INFORMATION) DELIVERED VIA EMAIL AND INCLUDING ANY SUPPLEMENTARY PHOTOS, SKETCHES, OR PLAN MARKUPS AS MAY BE USEFUL TO ASSIST IN THE RESOLUTION OF THE QUESTION. EXISTING (AS-BUILT) DIMENSIONS: •ALL DIMENSIONS ARE GIVEN TO THE FACE OF EXISTING FINISH MATERIALS NEW CONSTRUCTION DIMENSIONS: ALL DIMENSIONS ARE GIVEN TO THE FOLLOWING SURFACES, UNLESS NOTED OTHERWISE: •TO THE EXTERIOR FACE OF EXTERIOR WALL STUDS OR CONCRETE WALLS •TO THE CENTERLINE OF STRUCTURAL COLUMNS •TO THE FACE OF INTERIOR WALL STUDS •TO THE TOP OF STUD WALL DOUBLE TOP PLATES •TO THE TOP SURFACE OF PLYWOOD OR DECKING SUB-FLOOR PROJECT DESCRIPTION CONSTRUCTION OF A NEW ADDITION TO THE EXISTING SINGLE FAMILY RESIDENCE FOUNDATION DAMP-PROOFING: •CONTRACTOR SHALL APPLY ASPHALT EMULSION DAMP-PROOFING TO ALL BELOW GRADE FOUNDATION WALLS PER IRC R406.1. ENSURE THAT EXTERIOR SURFACES ARE CLEAN AND DRY PRIOR TO MEMBRANE APPLICATION. FILL ANY HONEYCOMBED AREAS, CRACKS, AND FORMWORK HOLES WITH NON-SRINK CEMENT GROUT PRIOR TO APPLICATION, PER MANUFACTURER'S INSTRUCTIONS. ALL BELOW GRADE FOUNDATION WALLS TALLER THAN 48" HIGH SHALL ALSO BE PROTECTED WITH A LAYER OF PLASTIC DRAIN MAT (DIMPLE BOARD) FASTENED TO THE WALL SURFACE PER MANUFACTURER'S INSTRUCTIONS. (COSELLA- DORKEN "DELTA-MS" MEMBRANE AND "DELTA-DRAIN" DRAIN MAT, AND ENKADRAIN 3000R DRAINAGE, OR EQUIVALENT). GUTTERS & DOWNSPOUTS: •CONTRACTOR SHALL PROVIDE "K-STYLE" GUTTERS AT ALL SLOPED ROOFS, UNLESS DIRECTED OTHERWISE BY HOMEOWNER. LAP ROOF EAVE FLASHING TO DISCHARGE INTO EDGE GUTTERS. PROVIDE APPROPRIATELY SIZED DOWNSPOUTS WHICH DISCHARGE INTO NEW 4" DIAMETER TIGHTLINE STORM DRAINAGE LEADERS WHICH ARE ROUTED INTO A SUITABLE STORM DRAINAGE SYSTEM OR OTHER APPROVED DRAINAGE DISCHARGE BMP SYSTEM. ROOF FLASHING: •CONTRACTOR SHALL PROVIDE METAL FLASHING AND OTHER WEATHER PROTECTION MATERIALS AS STATED IN IRC R903 AND R905. VALLEY FLASHING SHALL BE WITH STANDARD V-CRIMPED ENAMELED METAL. ROOF TO MASONRY CONDITIONS SHALL HAVE STANDARD ENAMELED METAL STEP-FLASHING AND COUNTER-FLASHING AS REQUIRED. PROVIDE ALL DOOR, WINDOW, DECK, LEDGER, AND OTHER FLASHING AS REQUIRED PER IRC. EXTERIOR FINISHES: •EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER-RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE SHALL INCLUDE FLASHING AS DESCRIBED IN IRC R703. THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED IN SUCH A MANNER AS TO PREVENT THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTIVE BARRIER BEHIND THE EXTERIOR VENEER AS REQUIRED BY IRC R703.2. DATE: SHEET SIZE: DRAWING: 22" x 34"ENGINEERED STRUCTURESGLOBAL DESIGN, PLLCDRAWINGS PROVIDED BY: !" # $%&’()%*)&%+,2-$-2 1/26/2022 6:42:07 PMA0.2GENERAL NOTES2/6/2022KAIWI ADDITION4114 NE 2ND ST,RENTON, WA 98059NEW ADDITIN TO FOLLOW "PERSCRIPTIVE" METHOD COMPLYING WITH THE 2018 WASHINGTON STATE ENERGY CODE (WSEC). NEW ADDITION IS CLASSIFIED AS ADDITION LESS THAN 500 SQ.FT, NEEDING 1.5 CREDITS (SELECTED BELOW). 0.5 CREDITS 1.0 CREDITS •ADDITIONS TO AN EXISTING BUILDING, BUILDING SYSTEM OR PORTION THEREOF SHALL CONFORM TO THE PROVISIONS OF THIS CODE AS THOSE PROVISIONS RELATE TO NEW CONSTRUCTION WITHOUT REQUIRING THE UNALTERED PORTION OF THE EXISTING BUILDING OR BUILDING SYSTEM TO COMPLY WITH THIS CODE (WSEC R502). •ALTERATIONS TO ANY BUILDING OR STRUCTURE SHALL COMPLY WITH THE REQUIREMENTS OF THE CODE FOR NEW CONSTRUCTION. ALTERATIONS SHALL BE SUCH THAT THE EXISTING BUILDING OR STRUCTURE IS NO LESS CONFORMING TO THE PROVISIONS OF THIS CODE THAN THE EXISTING BUILDING OR STRUCTURE WAS PRIOR TO THE ALTERATION (WSEC R503.1). •BUILDING ENVELOPE ASSEMBLIES THAT ARE PART OF THE ALTERATION SHALL COMPLY WITH WSEC TABLE R402.1.1 MINIMUM PRESCRIPTIVE REQUIREMENTS FOR NEW CONSTRUCTION (WSEC R503.1.1). •ALTERATIONS NEED NOT COMPLY WITH THE REQUIREMENTS FOR NEW CONSTRUCTION PROVIDED THE ENERGY USE OF THE BUILDING IS NOT INCREASED AND THE EXISTING ROOF, WALL OR FLOOR CAVITY IS NOT EXPOSED. IF EXISTING CEILING, WALL OR FLOOR CAVITIES ARE EXPOSED DURING CONSTRUCTION, THOSE TO BE FILLED WITH INSULATION. 2x4 FRAMED WALLS SHALL BE INSULATED TO A MINIMUM OF R-15 AND 2x6 FRAMED WALLS SHALL BE INSULATED TO A MINIMUM OF R-21 (WSEC R503.1.1). WHOLE HOUSE VENTILATION NOTES: •FOLLOW ALL APPLICABLE REQUIREMENTS OF IRC CHAPTER 15. •LAUNDRY, BATH AND UTILITY ROOM FANS TO BE INSTALLED IN ACCORDANCE WITH WSEC TABLE 403.6.1. •ALL EXHAUSTS SHALL TERMINATE OUTSIDE NOT LESS THAN 3 FEET FROM PROPERTY LINES; 3 FEET FROM OPERABLE/NON-OPERABLE OPENINGS INTO BUILDING AND 10 FEET FROM MECHANICAL AIR INTAKES, EXCEPT WHERE OPENING IS 3 FEET ABOVE AIR INTAKE •OUTDOOR AIR SHALL BE DISTRIBUTED TO EACH HABITABLE ROOM BY INDIVIDUAL OUTDOOR AIR INLETS PER IRC M1505. •FOLLOW PRESCRIPTIVE WHOLE HOUSE VENTILATION SYSTEM FOR INTERMITTENT WHOLE HOUSE VENTILATION USING EXHAUST FANS (IRC M1505). •WHOLE HOUSE FAN TO BE CONTROLLED BY 24 HOUR TIMER WITH THE CAPABILITY OF CONTINUOUS OPERATION, MANUAL AND AUTOMATIC CONTROL. •CALCULATIONS: PER IRC TABLE M1505.4.3.(1) - 1,501-3,000 sq.ft.; 5BR: 75CFM REQUIRED. ATTIC/ROOF VENTILATION NOTES: (SEE IRC R806 FOR FURTHER VENTILATION REQUIREMENTS) •PROVIDE CONTINUOUS EAVE VENTS, RIDGE VENTS, AND SIDEWALL VEN TS, AS REQUIRED PER CODE. (RECOMMEND "COR-A-VENT" OR EQUIVALENT PRODUCTS). •PROVIDE APPROVED BUG SCREEN AT ALL VENTILATION AS REQ'D. •PROVIDE 1" MIN. CLEARANCE ABOVE INSULATION FOR VENTILATION. •PLACE NO SOFFIT VENTING WITHIN 5'-0" OF PROPERTY LINE. ADDITIONAL ENERGY CODE NOTES: •NATURAL LIGHTING IN ALL HABITABLE SPACES SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA OF NOT LESS THAN 8% OF THE FLOOR AREA OF EACH SPACE (IRC R303.1). •A RESIDENTIAL ENERGY COMPLIANCE CERTIFICATE COMPLYING WITH WSEC R401.3 IS REQUIRED TO BE COMPLETED BY THE BUILDER AND PERMANENTLY POSTED WITHIN 3' OF THE ELECTRICAL PANEL PRIOR TO FINAL INSPECTION. •EACH DWELLING UNIT IS REQUIRED TO BE PROVIDED WITH AT LEAST ONE PROGRAMMABLE THERMOSTAT FOR THE REGULATION OF TEMPERATURE IN COMPLIANCE WITH WSEC R403.1.1. •A SIGNED AFFIDAVIT DOCUMENTING THE DUCT LEAKAGE TEST RESULTS IN COMPLIANCE WITH WSEC R403.3.3 SHALL BE PROVIDED TO THE BUILDING INSPECTOR PRIOR TO AN APPROVED FINAL INSPECTION. •A MINIMUM OF 90 PERCENT OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES SHALL BE HIGH-EFFICIENCY LED OR CFL. •WINDOW AND DOOR HEADERS SHALL BE INSULATED WITH A MINIMUM OF R-10 INSULATION •NEW WINDOWS AND DOORS U-VALUE NOT TO EXCEED 0.3 DRAWING INDEX SHEET #SHEET NAME SP SITE PLAN A0.1 GENERAL NOTES A0.2 GENERAL NOTES A1.1 EXISTING FLOOR PLANS A1.2 PROPOSED FLOOR PLANS A1.3 PROPOSED ROOF PLAN A2.1 EXISTING ELEVATIONS A2.2 PROPOSED ELEVATIONS A3.1 SECTIONS A4.1 ARCHITECTURAL DETAILS S1 STRUCTURAL NOTES S2 ADDITION FOUNDATION / MAIN FLOOR FRAMING PLAN S3 ADDITION ROOF FRAMING PLAN S4 STRUCTURAL DETAILS S5 STRUCTURAL DETAILS ENERGY CODE COMPLIANCE NOTES R-38 PER 1.3 TABLE 406.3 U-28 PER 1.3 TABLE 406.3 1.3 - EFFICIENT BUILDING ENVELOPE VERTICAL FENESTRATION U = 0.28 FLOOR R-38 3.2 - HIGH EFFICIENCY HVAC EQUIPMENT AIR-SOURCE CENTRALLY DUCTED HEAT PUMP WITH MINIMUM HSPF OF 9.5 TO BE INSTALLED. #1 TABLE R406.2 -FUEL NORMALIZATION CREDITS HEATING SYSTEM USING HEAT PUMP THAT MEETS STANDARDS LISTED IN TABLE C403.3.2(1) OR C403.3.2(2) ENERGY CODE. 1.0 CREDITS DW X WINDOW TAG, (REFER TO WINDOW SCHEDULE) DOOR TAG, (REFER TO DOOR SCHEDULE)X FLOOR PLAN LEGEND: EXISTING FRAME WALL (LINE OF STUD) DINING ROOM KITCHEN LIVING ROOM GARAGE UP PWDR ROOM LAUNDRY 1E 2E1E2E 3E 6E 3E 4E 5E FAMILY ROOM 8E 4E 5E 6E 7ECHIMNEYFIREPLACE 9E 10E CONCRETE PATIO FURNACE WH ENTRY 7E 7.5" STEP 2' - 8 1/2"5' - 0"7' - 6"3' - 0"4' - 1 1/2"3' - 0"6' - 0"1' - 0"5' - 0" 1' - 4 1/2" 5' - 3 1/2" 22' - 4"16' - 4 1/2"5' - 3 1/2" 44' - 0"24' - 0"1' - 8"3' - 10 1/2"1' - 9"5' - 0"1' - 9"4' - 3"1' - 5" 6" 3' - 0" 6" 1' - 10"8' - 0"2' - 2"8' - 0"1' - 11 1/2"20' - 8"1' - 6"2' - 0"1' - 10"5' - 10 1/2"5' - 10 1/2"5' - 4"20' - 8"31' - 10 1/2"22' - 0 1/2"21' - 11 1/2"2' - 1"2' - 1" 2' - 4" 2' - 8"5' - 0" PONY WALL PONY WALL PONY WALL DN DN REF.7.5" STEP3' - 5"3' - 3 1/2"44' - 0"7.5" STEPDN MASTER BEDROOM MASTER BATH UPPER BATH BEDROOM 2 BEDROOM 3 8E 9E 10E 12E 13E 19E 17E 18E 20E 15E 16EWIC WIC 11E 14E 3' - 10"4' - 6"2' - 4"3' - 4 1/2"4' - 6"3' - 5" 10' - 8"11' - 3 1/2"10' - 11"2' - 3 1/2"5' - 3 1/2"7' - 11 1/2"5' - 5"5' - 4 1/2"5' - 10"5' - 2"5' - 7" 16' - 4 1/2"5' - 7" 21' - 11 1/2"11' - 6"3' - 3 1/2"3' - 10 1/2"13' - 2 1/2"4' - 11"1' - 11"7' - 11 1/2" MAIN FLOOR ROOF BELOW 31' - 10 1/2"21' - 11 1/2" DATE: SHEET SIZE: DRAWING: 22" x 34"ENGINEERED STRUCTURESGLOBAL DESIGN, PLLCDRAWINGS PROVIDED BY: !" # $%&’()%*)&%+,2-$-2 1/26/2022 6:42:07 PMA1.1EXISTING FLOORPLANS2/6/2022KAIWI ADDITION4114 NE 2ND ST,RENTON, WA 98059EXISTING DOOR SCHEDULE Mark Width Height Area Stay / Remove 1E 5' - 0"6' - 8"33 SF Stay 2E 5' - 0"6' - 8"33 SF Remove 3E 2' - 6"6' - 8"17 SF 4E 2' - 6"6' - 8"17 SF Stay 5E 2' - 8"6' - 8"18 SF Stay 6E 2' - 6"6' - 8"17 SF Stay 7E 2' - 4"6' - 8"16 SF Stay 8E 3' - 0"6' - 8"20 SF Stay 9E 8' - 0"7' - 0"56 SF Stay 10E 8' - 0"7' - 0"56 SF Stay 11E 2' - 4"6' - 8"16 SF Stay 12E 2' - 4"6' - 8"16 SF Stay 13E 2' - 6"6' - 8"17 SF Stay 14E 1' - 4"6' - 8"9 SF Stay 15E 2' - 4"6' - 8"16 SF Stay 16E 2' - 6"6' - 8"17 SF Stay 17E 2' - 6"6' - 8"17 SF Stay 18E 2' - 6"6' - 8"17 SF Stay 19E 2' - 4"6' - 8"16 SF Stay 20E 5' - 10"6' - 8"39 SF Stay Total Doors: 20 459 SF EXISTING WINDOW SCHEDULE Mark Width Height Header Height Area Stay / Remove 1E 3' - 0"3' - 5"7' - 5"10 SF Stay 2E 6' - 0"3' - 10"6' - 8"23 SF Remove 3E 2' - 0"3' - 0"6' - 10"6 SF Stay 4E 1' - 5"4' - 10"7' - 5"7 SF Stay 5E 1' - 4"4' - 10"7' - 2"6 SF Stay 6E 5' - 0"4' - 10"7' - 2"24 SF Stay 7E 1' - 4"4' - 10"7' - 2"6 SF Stay 8E 5' - 10"4' - 0"7' - 0"23 SF Stay 9E 4' - 6"3' - 10"6' - 10"17 SF Stay 10E 4' - 6"3' - 10"6' - 10"17 SF Stay Total Windows: 10 141 SF 1/4" = 1'-0" EXISTING FLOOR PLAN -MAIN LEVEL 1/4" = 1'-0" EXISTING FLOOR PLAN -UPPER LEVEL EXISTING FLOOR AREA MATRIX LEVEL MAIN FLOOR TOTAL GARAGE, SF PORCHES/ DECKS, SF TOTAL GROSS AREA, SF 454 454 320 320 2,270 1,570 (AREAS ARE CALCULATED ON THE OUTSIDE FACE OF WALLS) UPPER FLOOR 0 0 700 RESIDENTIAL AREA, SF 796 1,496 700 Stay DW (N) ADDITION BEDROOM 1 (N) ADDITION BEDROOM 2 (N) BATH SEE NOTE #6 SD/CO SD/CO (E) LIVING ROOM (E) GARAGE 2N 3N 4N 1N 7N (E) FAMILY ROOM 3N (E) LAUNDRY (E) PWDR ROOM (E) KITCHEN(E) DINING ROOM 3' - 2"5' - 0"3' - 0"2' - 8"5' - 0"3' - 2" 11' - 2"10' - 10" 22' - 0" 4' - 4" (N) HALL 3' - 6"3' - 4"14' - 1"2' - 3 1/2"5' - 7 1/2"22' - 0"DN DN (E) ENTRY12' - 2 1/2"2' - 6"8"3' - 0"3' - 2"12' - 2 1/2"2' - 6"6' - 10"(E) WINDOW TO BE REMOVED 5' - 3 1/2" REF.EXISTING RESIDENCE NEW ADDITIONSD/CO UP 5' TUB A A3.1 A A3.1 B A3.1 B A3.1 24"x18" CRAWL SPACE ACCESS21' - 6 1/2"NARROW DOWN (E) DOOR OPENING 6' - 8" 2N 6N5N 4' - 2"7' - 0"3' - 5" 3' - 8 1/2" 10"2' - 0" 10 1/2" 1N 2' - 5 1/2"1' - 0"2' - 2"4N (N) PATIO ROOF POSTS (N) COVERED CONCRETE PATIO 11' - 2"11' - 2"3' - 8 1/2"12' - 0"FLOOR PLAN LEGEND: EXISTING FRAME WALL TO REMAIN (LINE OF STUD) NEW FRAME WALL (LINE OF STUD) EXISTING FRAME WALL TO BE REMOVED (LINE OF STUD) SD/CO SMOKE ALARM, CARBON MONOXIDE DETECTOR E EXHAUST FAN, SEE PLAN FOR SIZE EGRESS WINDOW/DOOR (REFER TO "WINDOW/DOOR" NOTES ON SHEET A0.1 FOR REQUIREMENTS) SG SAFETY GLAZING (REFER TO "GLAZING" NOTES ON SHEET A0.1 FOR REQUIREMENTS) VTO VENTED TO OUTSIDE (E) MASTER BEDROOM (E) MASTER BATH (E) BATH 2 BEDROOM 2 BEDROOM 3 (E) WIC DN (E) MAIN FLOOR ROOF BELOW SLOPE (N) ADDITION ROOF 4" / 12" SLOPE 4" / 12" (E) WIC FLOOR PLAN NOTES: 1.CONTRACTOR SHALL REFER TO A0.1 AND A0.2 GENERAL RESIDENTIAL PROJECT NOTES FOR STANDARD CONSTRUCTION SPECIFICATIONS AND INSTALLATION NOTES, UNO. 2.ALL NEW EXTERIOR WALL STUDS TO BE 2x6 3.ALL NEW INTERIOR WALL STUDS TO BE 2x4 4.ALL DIMENSIONES ARE TO FACE OF WALL STUDS, FACE OF CONCRETE WALLS, OUTSIDE DECK FRAMING, CENTER OF POSTS, CENTER OF BEAMS, UNO. 5.COORDINATE AND PROVIDE BACKING FOR MILLWORK AND ITEMS ATTACHED OR MOUNTED TO WALLS OR CEILINGS. 6.75 CFM CONTINUOUSLY OPERATING WHOLE HOUSE FAN TO BE INSTALLED AT NEW ADDITION BATHROOM. 7.AIR EXHAUST OPENINGS SHALL TERMINATE ON THE OUTSIDE OF THE BUILDING NOT LESS THAN 3 FEET IN ANY DIRECTION FROM OPENINGS INTO THE BUILDING AND 10 FEET FROM MECHANICAL AIR INTAKES, EXCEPT WHERE THE OPENING IS LOCATED 3 FEET ABOVE THE AIR INTAKE.(IRC M1504.3) 8.WINDOW AND DOOR HEADERS SHALL BE INSULATED WITH A MINIMUM OF R-10 INSULATION. 9.ALL NEW WINDOWS AND DOOR TO HAVE MAX. U = 0.28 10.EXISTING FURNACE OR BOILER TO MATCH OR INCREASE FOLLOWING REQUIREMENTS: •ENERGY STAR RATED (U.S. NORTH) GAS OR PROPANE FURNACE WITH MINIMUM AFUE OF 95% OR •ENERGY STAR RATED (U.S. NORTH) GAS OR PROPANE BOILER WITH MINIMUM AFUE OF 90%. DATE: SHEET SIZE: DRAWING: 22" x 34"ENGINEERED STRUCTURESGLOBAL DESIGN, PLLCDRAWINGS PROVIDED BY: !" # $%&’()%*)&%+,2-$-2 1/26/2022 6:42:08 PMA1.2PROPOSED FLOORPLANS2/6/2022KAIWI ADDITION4114 NE 2ND ST,RENTON, WA 980591/4" = 1'-0" PROPOSED FLOOR PLAN -MAIN LEVEL PROPOSED DOOR SCHEDULE Mark Width Height Area 1N 3' - 0"6' - 8"20 SF 2N 2' - 6"6' - 8"17 SF 3N 2' - 8"6' - 8"18 SF 4N 2' - 8"6' - 8"18 SF 5N 6' - 8" 6N 5' - 0"6' - 8"33 SF 7N 6' - 8" Total Doors: 7 142 SF PROPOSED WINDOW SCHEDULE Mark Width Height Header Height Area 1N 2' - 0"3' - 10"6' - 8"8 SF 2N 5' - 0"3' - 10"6' - 8"19 SF 3N 5' - 0"3' - 10"6' - 8"19 SF 4N 3' - 0"1' - 0"6' - 8"3 SF Total Windows: 4 49 SF(AREAS ARE CALCULATED ON THE OUTSIDE FACE OF WALLS) 1/4" = 1'-0" PROPOSED FLOOR PLAN -UPPER LEVEL PROPOSED FLOOR AREA MATRIX LEVEL MAIN FLOOR TOTAL GARAGE, SF PORCHES / DECKS, SF TOTAL GROSS AREA, SF 454 454 320 320 2,756 2,056 UPPER FLOOR 0 0 700 RESIDENTIAL AREA, SF 1,282 1,982 700 2' - 8" 2' - 8" 18 SF 18 SF ROOF PLAN LEGEND: DIRECTION OF DOWNWORD SLOPE DS NEW DOWNSPOUT ROOF PLAN NOTES: 1. ALL GUTTERS TO BE 4" BOX ALUMINUM AND PAINTED. 2. DOWNSPOUTS TO BE 3" ROUND ALUMINUM AND PAINTED. 3. PROVIDE 1 SF OF VENT AREA FOR EACH 300 SF OF ROOM AREA FOR BATT INSULATED ROOF. 4. PROVIDE 2" MIN. CONTIUOUS SCREEN VENT AT EACH END OF EACH RAFTER / ROOF TRUSS BAY. 5. CONTRACTOR TO VERIFY EXISTING ROOF SLOPES. 6. NEW ROOFING MATERIAL TO BE ASPHALT COMPOSITION SHINGLES (MATCH EXISTING). NEW ROOF INSULATED (N) ROOF AREA: 476 SF REQUIRED VENT AREA: 476 SF / 150 = 3.2 SF PROVIDED VENT AREA: 43.5 LF * 2/12 = 7.2 SF (CONTIUOUS SCREEN VENT AT EACH END OF EACH TRUSS BAY) ROOF VENTS CALCULATION: A A3.1 A A3.1 B A3.1 B A3.1 DS 4" / 12" SLOPE 4" / 12" SLOPE DS (N) RIDGEEXISTING RESIDENCE NEW ADDITION1' - 6"11' - 0"11' - 0"1' - 6" 25' - 0"1' - 0"24' - 6"4" / 12"4" / 12"(E) RIDGE4" / 12"SLOPESLOPESLOPESOFFIT VENT (21.5 LF)1' - 6"21' - 6 1/2"SOFFIT VENT (22 LF)(E) SKYLIGHT 4 A4.1 5 A4.1 DS DS 1' - 6"(N) 2'x4' SKYLIGHT(N) PATIO ROOF 1' - 6"7' - 0"5' - 0"1' - 0"14' - 6"1' - 0"11' - 2"11' - 4"1' - 11 1/2"1' - 7" 6' - 2 1/2"5' - 11 1/2"5' - 11 1/2"4' - 11"(N) 2'x4' SKYLIGHT(N) 2'x4' SKYLIGHT(N) PATIO ROOF BEAM AND POSTS PER FRAMING PLAN (N) PATIO ROOF BEAM AND POSTS PER FRAMING PLAN DSDS 27' - 0 1/2" (N) PATIO ROOF 3" / 12" DATE: SHEET SIZE: DRAWING: 22" x 34"ENGINEERED STRUCTURESGLOBAL DESIGN, PLLCDRAWINGS PROVIDED BY: !" # $ %&’()%*)&%+,2-$-2 1/26/2022 6:42:08 PMA1.3PROPOSED ROOFPLAN2/6/2022KAIWI ADDITION4114 NE 2ND ST,RENTON, WA 980591/4" = 1'-0" PROPOSED ADDITION ROOF / PATIO ROOF PLAN MAIN LEVEL 0' -0" UPPER LEVEL 9' -6"11' - 8"9' - 6"4 " / 1 2 "4" / 12"12' - 7"21' - 2" 12' - 7" MAIN LEVEL 0' -0" UPPER LEVEL 9' -6" 9E 10E 9E 10E8E 4E 4 " / 1 2 "11' - 8"9' - 6"12' - 7"4" / 12" 6E4" / 12"7 1/2"21' - 2" 12' - 7" ELEVATION LEGEND: SG SAFETY GLAZING X WINDOW TAG DOOR TAGX SLIDING WINDOW / DOOR OPERATION DIRECTION DASHED LINES SYMBOLIZE CASEMENT WINDOW / DOOR OPERATION DIRECTION WITH HINGES LOCATED ON LINE INTERSECTION SIDE MAIN LEVEL 0' -0" UPPER LEVEL 9' -6" 8E 2E 1E 1E 2E 4" / 12"4 " / 1 2 "4" / 12"9' - 6"11' - 8"12' - 7"7 1/2"21' - 2" 12' - 7" MAIN LEVEL 0' -0" UPPER LEVEL 9' -6" 3E11' - 8"9' - 6"4" / 12"21' - 2" DATE: SHEET SIZE: DRAWING: 22" x 34"ENGINEERED STRUCTURESGLOBAL DESIGN, PLLCDRAWINGS PROVIDED BY: !" # $ %&’()%*)&%+,2-$-2 1/26/2022 6:42:09 PMA2.1EXISTINGELEVATIONS2/6/2022KAIWI ADDITION4114 NE 2ND ST,RENTON, WA 980593/16" = 1'-0" EXISTING LEFT ELEVATION 3/16" = 1'-0" EXISTING FRONT ELEVATION 3/16" = 1'-0" EXISTING REAR ELEVATION 3/16" = 1'-0" EXISTING RIGHT ELEVATION ELEVATION LEGEND: SG SAFETY GLAZING X WINDOW TAG DOOR TAGX SLIDING WINDOW / DOOR OPERATION DIRECTION DASHED LINES SYMBOLIZE CASEMENT WINDOW / DOOR OPERATION DIRECTION WITH HINGES LOCATED ON LINE INTERSECTION SIDE MAIN LEVEL 0' -0" UPPER LEVEL 9' -6" 4 " / 1 2 "11' - 8"9' - 6"12' - 7"4" / 12"7 1/2"4" / 12"EXISTING RESIDENCE NEW ADDITION "HARDIEPANEL" VERTICAL SIDING (MATCH (E) RESIDENCE SIDING) 9E 10E 8E 4E 9E 10E 6E 21' - 2" 12' - 7" MAIN LEVEL 0' -0" UPPER LEVEL 9' -6"11' - 8"9' - 6"1N4" / 12"4" / 12"4 " / 1 2 " EXISTING RESIDENCE NEW ADDITION ASPHALT SHINGLE ROOFING "HARDIEPANEL" VERTICAL SIDING (MATCH (E) RESIDENCE SIDING) 12' - 8" 21' - 2" 12' - 7"12' - 8"7' - 3"(N) PATIO ROOF MAIN LEVEL 0' -0" UPPER LEVEL 9' -6"11' - 8"9' - 6"4" / 12"12' - 8"EXISTING RESIDENCE NEW ADDITION ASPHALT SHINGLE ROOFING "HARDIEPANEL" VERTICAL SIDING (MATCH (E) RESIDENCE SIDING) 3E 12' - 8" 21' - 2" 4N 4" / 12"MAIN LEVEL 0' -0" UPPER LEVEL 9' -6" 4" / 12" 4 " / 1 2 "12' - 7"7 1/2"2N3N 9' - 6"11' - 4""HARDIEPANEL" VERTICAL SIDING (MATCH (E) RESIDENCE SIDING) 8E 4" / 12" 4 " / 1 2 " 1E 1E 21' - 2" 12' - 7"12' - 8" 1N (N) PATIO ROOF3" / 12" DATE: SHEET SIZE: DRAWING: 22" x 34"ENGINEERED STRUCTURESGLOBAL DESIGN, PLLCDRAWINGS PROVIDED BY: !" # $ %&’()%*)&%+,2-$-2 1/26/2022 6:42:10 PMA2.2PROPOSEDELEVATIONS2/6/2022KAIWI ADDITION4114 NE 2ND ST,RENTON, WA 980593/16" = 1'-0" PROPOSED FRONT ELEVATION 3/16" = 1'-0" PROPOSED LEFT ELEVATION 3/16" = 1'-0" PROPOSED RIGHT ELEVATION 3/16" = 1'-0" PROPOSED REAR ELEVATION MAIN LEVEL 0' -0" (N) HALL 4" / 12"12' - 8"(N) FOUNDATION PER PLAN (N) FOOTING DRAIN PER CODE, TYP. CONNECT TO (E) FOOTING DRAIN OR TO SUITABLE DRAINAGE DISCHARGE LOCATION (N) ROOF ASSEMBLY ASPHALT SHINGLE ROOFING #15 FELT PAPER ROOF SHEATHING PER STRUCTURAL NOTES ROOF TRUSSES PER MANUFACTURER @24"oc R-49 BATT CEILING INSULATION 5/8" GWB 3N 4N 8' - 8" TOP PLATE EL. MATCH w/ (E) HOUSE TOP PLATE (N) EXTERIOR WALL ASSEMBLY "HARDIEPANEL" VERTICAL SIDING VAPORSHIELD MEMBRANE WRAP WALL SHEATHING PER STRUCTURAL SW SCHEDULE 2x6 WALL STUDS @16”oc R-21 BATT CAVITY INSULATION 1/2" GWB (N) FLOOR OVER CRAWL SPACE ASSEMBLY FINISHED FLOORING T&G PLYWOOD PER STRUCTURAL NOTES FLOOR JOISTS PER FRAMING PLAN R-38 BATT INSULATION 8' - 8" TOP PLATE EL. MATCH w/ (E) RESIDENSE TOP PLATE 4 " / 1 2 "18" MIN.B A3.1 B A3.1 1N 6" MIN.12' - 8"8' - 8"A4.1 4 (N) CRAWL SPACE POSTS w/ FOOTINGS PER PLAN 6N MAIN LEVEL 0' -0" A A3.1 A A3.1 2N 1N (N) FOUNDATION PER PLAN (N) ROOF ASSEMBLY ASPHALT SHINGLE ROOFING #15 FELT PAPER ROOF SHEATHING PER STRUCTURAL NOTES ROOF TRUSSES PER MANUFACTURER @24"oc R-49 BATT CEILING INSULATION 5/8" GWB (N) FLOOR OVER CRAWL SPACE ASSEMBLY FINISHED FLOORING T&G PLYWOOD PER STRUCTURAL NOTES FLOOR JOISTS PER FRAMING PLAN R-38 BATT INSULATION (N) EXTERIOR WALL ASSEMBLY "HARDIEPANEL" VERTICAL SIDING VAPORSHIELD MEMBRANE WRAP WALL SHEATHING PER SW SCHEDULE 2x6 WALL STUDS @16”oc R-21 BATT CAVITY INSULATION 1/2" GWB (N) ADDITION BEDROOM 1(N) HALL (N) FOOTING DRAIN PER CODE, TYP CONNECT TO (E) FOOTING DRAIN OR TO SUITABLE DRAINAGE DISCHARGE LOCATION (N) CRAWL SPACE POSTS w/ FOOTINGS PER PLAN (N) CRAWL SPACE FLUSH BEAM PER FRAMING PLAN 8' - 8" TOP PLATE EL. MATCH w/ (E) RESIDENCE TOP PLATE 8' - 8"18" MIN.6" MIN.(E) FAMILY ROOM (E) MASTER BEDROOM 8' - 8"7' - 8"(E) FOUNDATION TO REMAIN (E) RESIDENCE FLOOR TO REMAIN (E) FLOOR STRUCTURE TO REMAIN (E) EXTERIOR WALL TO REMAIN (E) ROOF STRUCTURE TO REMAIN EXISTING RESIDENCE NEW ADDITION NARROW DOWN (E) DOOR OPENING (E) HDR TO REMAIN MATCH (N) ADDITION FLOOR ELEVATIONS WITH (E) RESIDENCE FLOOR ELEVATIONS A4.1 1 A4.1 2 A4.1 5 DATE: SHEET SIZE: DRAWING: 22" x 34"ENGINEERED STRUCTURESGLOBAL DESIGN, PLLCDRAWINGS PROVIDED BY: !" # $ %&’()%*)&%+,2-$-2 1/26/2022 6:42:10 PMA3.1SECTIONS2/6/2022KAIWI ADDITION4114 NE 2ND ST,RENTON, WA 980593/8" = 1'-0" (N) ADDITION SECTION A-AA 3/8" = 1'-0" (N) ADDITION SECTION B-BB 6 MIL POLYTHYLENE GROUND COVER, 6" MIN. LAP 8"-CONC. STEM WALL w/ REBAR PER STRUCTURAL DETAIL CONC. FOOTING w/ REBAR PER STRUCTURAL DETAILS 1/2" GWB FINISHED FLOORING WALL SHEATHING PER SHEARWALL PLAN SIDING PER ELEVATIONS R-21 BATT INSULATION R-38 BATT INSULATION T&G PLYWOOD PER STRUCTURAL NOTES 2x6 STUDS @16" oc FLOOR JOIST w/ HANGER PER FRAMING PLAN PT 2x6 SILL PLATE w/ A.B. PER SHEARWALL PLAN PT LEDGER w/ ANCHORS PER FRAMING PLAN 4" PERF. FOOTING DRAIN w/ 4" LAYER OF GRAVEL AROUND, CONNECT TO (E) FOOTING DRAIN OR TO SUITABLE DRAINAGE DISCHARGE LOCATION FINISHED GRADE 6" MIN.1' - 6" MIN.(12" UNDER BEAMS)18" MIN.PER PLAN SIZE FOUNDATION VENTS w/ AIR BAFFLES (N) 6 MIL POLYTHYLENE GROUND COVER, 6" MIN. LAP (N) FINISHED FLOORING (N) R-38 BATT INSULATION (N) T&G PLYWOOD PER STRUCTURAL (N) FLOOR JOIST w/ HANGER PER FRAMING PLAN (N) PT LEDGER w/ ANCHORS PER FRAMING PLAN (12" UNDER BEAMS)18 3/4" MIN.(E) FOOTING TO REMAIN (E) RESIDENCE FLOOR TO REMAIN (E) EXTERIOR WALL w/ SHEATHING TO REMAIN MATCH (N) ADDITION FLOOR ELEVATIONS WITH (E) RESIDENCE FLOOR ELEVATIONS (E) CONC. STEM WALL TO REMAIN (2)2x6 TOP PLATE WALL SHEATHING PER SW PLAN SIDING PER ELEVATIONS 2x6 STUDS @16" oc SOFFIT BOARD w/ CONTINUOUS SOFFIT VENT FASCIA BOARD ASPHALT SHINGLE ROOFING #15 FELT PAPER ROOF SHEATHING PER STRUCTURAL NOTES ROOF TRUSSES PER MANUFACTURER R-49 BATT ATTIC INSULATION 5/8" GWB VENTED BLOCKING PER TRUSS MANUFACTURER 1/2" GWB R-21 BATT INSULATION VENT BAFFLES 2x BLOCKING MIN 2x6 OUTLOOKER GABLE END TRUSS PER MANUFACTURER SIMPSON "LUS26" HANGER TRUSSES PER MANUFACTURER WALL SHEATHING PER SW PLAN SIDING PER ELEVATIONS 2x6 STUDS @16" oc (2)2x6 TOP PLATE 5/8" GWB 1/2" GWB R-21 BATT INSULATION R-49 BATT ATTIC INSULATION FASCIA BOARD ASPHALT SHINGLE ROOFING #15 FELT PAPER ROOF SHEATHING PER STRUCTURAL 2' MAX. SOFFIT BOARD NEW FOUNDATION WALLEXISTING FOUNDATION WALL EXISTING FOOTING NEW FOOTING 3"#4 x 24" @12"oc (MIN 2) @ STEM WALL DRILL AND EPOXY INTO EXISTING CONC. EMBED 4" (2) #4 x 24" @ FOOTING DRILL AND EPOXY INTO EXISTING CONC. EMBED 4" DATE: SHEET SIZE: DRAWING: 22" x 34"ENGINEERED STRUCTURESGLOBAL DESIGN, PLLCDRAWINGS PROVIDED BY: !" # $ %&’()%*)&%+,2-$-2 1/26/2022 6:42:10 PMA4.1ARCHITECTURALDETAILS2/6/2022KAIWI ADDITION4114 NE 2ND ST,RENTON, WA 980593/4" = 1'-0" (N) ADDITION FOUNDATION DETAIL1 3/4" = 1'-0" (N) ADDITION FLOOR LEDGER AT (E) FOUNDATION DETAIL2 3/4" = 1'-0" (N) ROOF FRAMING DETAIL4 3/4" = 1'-0" GABLE END TRUSS FRAMING DETAIL5 3/4" = 1'-0" NEW TO EXISTING FOUNDATION CONNECTION DETAIL3 2 / 11 / 2022 DATE: SHEET SIZE: DRAWING: 22" x 34"ENGINEERED STRUCTURESGLOBAL DESIGN, PLLCDRAWINGS PROVIDED BY: !" # $ %&’()%*)&%+,2/$-2 1/26/2022 6:42:10 PMS1STRUCTURALNOTES2/6/2022KAIWI ADDITION4114 NE 2ND ST,RENTON, WA 98059THE FOLLOWING NOTES APPLY EXCEPT WHERE SHOWN OTHERWISE: CODE INTERNATIONAL RESIDENTIAL CODE IRC (2018) WOOD FRAME CONSTRUCTION MANUAL WFCM (2018) STRUCTURAL LOADS FLOOR LIVE LOADS: TYPICAL FLOOR DEAD LOAD = 15 PSF TYPICAL FLOOR LIVE LOAD = 40 PSF ROOF SNOW LOADS: GROUND SNOW LOAD, Pg = 25PSF ROOF SNOW LOAD, Pf = 25PSF (MIN) WIND LOADS: WIND ANALYSIS PROCEDURE: WFCM PART 2 BASIC WIND SPEED, V3S = 100-MPH WIND IMPORTANCE FACTOR, IW = 1.00 WIND EXPOSURE: 'B' TOPOGRAPHIC FACTOR, KZT = 1.0 DESIGN WIND PRESSURE ON MWFRS LATERAL = 73 PLF / UPLIFT = 131 PLF SEISMIC LOADS: SEISMIC ANALYSIS PROCEDURE: ASCE 7-16, CHAPTER 12.14 ENGINEERED DESIGN PER R301.1.3 SEISMIC USE GROUP:I SEIMIC IMPORTANCE FACTOR, IE = 1.0 MAPPED ACCELERATIONS, SS = 1.401; S1 = 0.479 SITE CLASS = 'D' DESIGN ACCELERATIONS, SDS = 1.121; SD1 = 0 SEISMIC DESIGN CATEGORY: 'D' BASIC SEISMIC FORCE RESISTING SYSTEM: PLYWOOD SHEAR WALLS RESPONSE MODIFICATION FACTOR, R = 6.5 STORY FORCE MULTIPLIER, F = 1.0 FOUNDATIONS MAXIMUM SOIL PRESSURE 1500 PSF (ASSUMED). EXTERIOR FOOTINGS SHALL BEAR 1'-0" (MINIMUM) BELOW FINISH GRADE. ALL FOOTINGS TO BEAR ON FIRM UNDISTURBED EARTH BELOW ORGANIC, SURFACE SOILS AND SHALL BE LOWERED IF SUITABLE SOIL IS NOT FOUND AT ELEVATIONS SHOWN ON DRAWINGS. BACKFILL TO BE THOROUGHLY COMPACTED PER SPECIFICATIONS. PROVIDE (2)#4 (MINIMUM) CONTINUOUS BOTTOM OF ALL WALLS AND FOOTINGS. CONCRETE MAX WATER/CEMENT RATIO MINIMUM f'c NON-AIR-ENT AIR-ENT SACKS/C.Y. REMARKS FOOTINGS AND FOUNDATIONS WALLS 2500 0.65 .54 5-1/2 SLABS ON GRADE 3000 0.58 .46 5-1/2 NOTE 1 1. AIR-ENTRAINING AGENT (3% TO 6%) TO BE USED IN ALL CONCRETE FLATWORK EXPOSED TO WEATHER. REINFORCING STEEL ASTM A615 GRADE 60. REINFORCING STEEL DETAILS SHALL BE PREPARED BY AN EXPERIENCED DETAILER AND CONFORM TO STANDARD PRACTICE OUTLINED IN ACI REPORT 315. FIELD WELDING OR TACK WELDING OF REINFORCING BARS IS PROHIBITED, EXCEPT AS APP ROVED BY THE ENGINEER. ANY REINFORCING TO BE WELDED TO BE ASTM A706, WELDABLE GRADE. MECHANICAL SPLICE DEVICES, IF REQUIRED, SHALL BE ICC APPROVED AND SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL. REINFORCING BARS SHALL BE LAP SPLICED FOR TENSION UNLESS NOTED OTHERWISE ON THE DRAWINGS. LAP FOUNDATION REINFORCING 32 DIAMETERS. OTHER LAP LENGTHS PER DRAWINGS. WELDED WIRE FABRIC TO BE ASTM A185. FABRIC TO BE SUPPORTED ON APPROVED CHAIRS. NOTE: REINFORCING STEEL NOT SPECIFICALLY SHOWN SHALL BE ASSUMED TYPICAL AS SIMILAR SECTIONS AND DETAILS WHERE REINFORCING IS SHOWN. CONCRETE COVER OF REINFORCING 3" CONCRETE POURED AGAINST EARTH. 2" FORMED CONCRETE WITH EARTH BACKFILL 1-1/2" OUTSIDE FACE OF WALLS EXPOSED TO WEATHER, SLABS ON MOISTURE BARRIER. CONCRETE SLABS STEEL SHALL BE RIGIDLY SUPPORTED USING CONCRETE BLOCKS OR CHAIRS MANUFACTURED IN ACCORDANCE WITH C.R.S.I. STANDARDS. USE #4 RAISER BAR FOR ALL SLABS. NON STRUCTURAL SLABS ON GRADE TO BE 4" THICK PLACED ON GRAVEL FILL BELOW RIGID IN SULATION PER ARCHITECT. SLAB EDGES SHALL BE FLOATING. REINFORCE WITH 6x6-W2.9 WWF OR #4 BARS AT 24"oc EACH WAY. AT THE CONTRACTOR'S OPTION, SLABS-ON-GRADE MAY BE REINFORCED WITH POLYPROPYLENE FIBERS IN LIEU OF WELDED WIRE FABRIC; DOSAGE PER FIBER MANUFACTURER. POLYPROPYLENE FIBERS MAY N OT BE USED IN LIEU OF REINFORCING BARS. ANCHORAGE TO HARDENED CONCRETE WHERE DRILL-IN ANCHORS ARE SPECIFIED, USE "SIMPSON TITEN-HD" SCREW ANCHORS. WHERE EPOXY ANCHORS ARE SPECIFIED, USE "SIMPSON AT-XP ADHESIVE”. USE ASTM A36 THREADED ROD OR #4 REBAR, UNLESS OTHERWISE NOTED. HOLES MUST BE CLEANED OF DUST AND DEBRIS AND BE FREE OF STANDING WATER WHEN EPOXY IS INSTALLED. SPECIAL INSPECTION OF EPOXY ANCHORS IS REQUIRED. DO NOT CUT ANY REINFORCING BARS TO INSTALL ANCHORS. DEFECTIVE HOLES SHALL BE FILLED SOLID WITH EPOXY. FOR ANY SUBSTITUTIONS TO THE ABOVE, THE CONTRACTOR SHALL SUBMIT TO THE STRUCTURAL ENGINEER MANUFACTURER'S LITERATURE DESCRIBING THE ANCHORS AND LISTING ICC APPROVED ALLOWABLE SHEAR AND TENSION VALUES. PLYWOOD/ OSB PLYWOOD/OSB ROOF, FLOOR AND WALL SHEATHING TO BE APA RATED C-D EXPOSURE 1 PER APA “PLYWOOD DESIGN SPECIFICATION”(Y510), UNLESS NOTED OTHERWISE. MAXIMUM NAIL SPACING SHALL BE AS FOLLOWS: 6"oc AT ALL SUPPORTED PANEL EDGES, AND 12"oc AT INTERMEDIATE SUPPORTS. NAILS SHALL BE AS FOLLOWS: 8D COMMON FOR 1/2" ROOF SHEATHING, 8D COMMON FOR 1/2" WALL SHEATHING. STAGGER END LAPS AT ROOF SHEATHING. ALL PANEL EDGES TO BE BLOCKED AT SHEAR WALLS. SUPPORT SHALL BE SUPPLIED TO ALL PLYWOOD EDGES WITH PLYCLIPS, BLOCKING, TONGUE AND GROOVE PLYWOOD JOINTS OR OTHER APPROVED METHODS PER APA RECOMMENDATION. TIMBER STRUCTURAL TIMBER AND LUMBER TO BE STRESS GRADE HEM-FIR OR DOUGLAS FIR AS FOLLOWS: USE SPECIES GRADE Fb BEAMS ENGINEERED (SEE PLAN) --- POSTS HEM-FIR NO. 2 750 PSI EXTERIOR & BEARING WALL STUDS HEM-FIR NO. 2 750 PSI SHEAR WALL STUDS, PLATES, AND BLOCKING HEM-FIR NO. 2 750 PSI ROOF JOISTS, FLOOR JOISTS HEM-FIR NO. 2 750 PSI INTERIOR STUDS AT NON-BEARING WALLS HEM-FIR STANDARD 550 PSI ALL OTHER LUMBER HEM-FIR STANDARD/BETTER --- WOOD AND WOOD BASED MATERIALS USED IN CONTACT WITH SOIL, CONCRETE OR MASONRY, INSTALLED WITHIN 1”OF CONCRETE OR MASONRY, OR EXPOSED TO MOISTURE EITHER INTERIOR OR EXTERIOR, SHALL BE TREATED WITH AN APPROVED PRESERVATIVE. SOLID BLOCKING OF NOT LESS THAN 2" NOMINAL THICKNESS SHALL BE PROVIDED AT ENDS AND AT ALL SUPPORTS OF JOISTS AND RAFTERS. BETWEEN SUPPORTS PROVIDE BLOCKING OR BRIDGING AT 8' -0" OC ALL SILL PLATES AT SHEAR WALLS TO BE 2x_ PRESERVATIVE TREATED HEM -FIR #2, U.N.O. ON THE PLANS. SILL PLATES SHALL HAVE A MOISTURE CONTENT OF NOT GREATER THAN 19% BEFORE BEING COVERED WITH INSULATION, INTERIOR WALL FINISH, FLOOR COVERING OR OTHER MATERIAL. STRUCTURAL GENERAL NOTES: WOOD CONNECTORS CAST-IN-PLACE SILL BOLTS TO BE 5/8" DIAMETER, EMBEDDED 7" INTO THE CONCRETE. MINIMUM SPACING OF BOLTS SHALL BE 60”oc AT DESIGNATED SHEAR WALLS SILL BOLT SPACING SHALL BE PER THE PLANS. USE GALVANIZED 3" x 3" x 1/4" PLATE WASHERS AT ALL SHEAR WALL SILL BOLTS. LOCATE EDGE OF WASHERS 1/2" MAX FROM INTERIOR EDGE OF WALL SHEATHING PROVIDE A MINIMUM OF TWO BOLTS EACH PIECE. PROVIDE ONE BOLT AT END OF EACH PIECE, NOT LESS THAN 6”AND NOT MORE THAN 12”FROM THE END. AT EXISTING CONCRETE STEM WALLS, USE 5/8" DIAMETER BY 6" LONG SIMPSON "TITEN-HD" SCREW ANCHORS. MINIMUM SPACING OF BOLTS SHALL BE 48"oc, OR AS SPECIFIED IN THE SHEAR WALL PLAN AND SCHEDULE. BOLT HEADS AND NUTS BEARING AGAINST WOOD TO BE PROVIDED WITH MALLEABLE IRON WASHERS EXCEPT ON STEEL BEAM NAILERS USE CUT WASHERS. NAILERS TO STEEL BEAMS SHALL BE ATTACHED WITH 5/8"BOLTS AT 24"oc STAGGERED. NAILS SHALL CONFORM TO REQUIREMENTS OF ASTM F 1667 AND HAVE A MINIMUM BENDING STRENGTH OF 90 KSI FOR SHANK DIAMETERS BETWEEN .142”AND .177”. ALL WOOD-TO-WOOD NAILING SHALL BE PER IBC TABLE 2304.9.1. IF PLANS AND DETAILS SPECIFY 8D, 10D OR 16D NAILS, THEY SHALL HAVE THE FOLLOWING PROPERTIES: 8D = 0.131”DIA x 2-1/2” 10D = 0.148”DIA x 3” 16D = 0.162”DIA x 3-1/2” ALL SUBSTITUTIONS SHALL HAVE THE WRITTEN APPROVAL OF THE ENGINEER OF RECORD PRIOR TO USE. LIGHT GAUGE METAL FRAMING CONNECTORS AND THEIR REQUIRED FASTENERS SHALL BE “STRONG-TIE”BY SIMPSON COMPANY, OR APPROVED EQUAL. ALL FASTENERS AND CONNECTORS IN CONTACT WITH PRESERVATIVE TREATED WOOD SHALL BE HOT-DIPPED GALVANIZED STEEL WITH A G185 SPECIFICATION OR TYPE 304 & 316 STAINLESS STEEL. TYPE 304 AND 316 STAINLESS STEEL SHOULD BE USED FOR ALL CONNECTORS AND FASTENERS IN CONTACT WITH AZCA TREATED WOOD AND SOME VARIATIONS OF ACQ TREATED WOODS. HOT-DIPPED GALVANIZED STEEL SHOULD NEVER COME IN CONTACT WITH STAINLESS STEEL. WOOD ROOF TRUSSES SHALL BE FACTORY FABRICATED TRUSSES. DESIGN AND FABRICATION SHALL CONFORM TO THE REQUIREMENTS OF THE IBC AND THE DESIGN SPECIFICATIONS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES PUBLISHED BY THE TRUSS PLATE INSTITUTE. ENGINEERING DESIGN AND SHOP DRAWINGS BEARING THE STAMP OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF WASHINGTON AND SHOWING ALL DETAILS OF CONSTRUCTION REQUIRED FOR A COMPLETE INSTALLATION SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT FOR REVIEW. PRESERVATIVE TREATMENT ALL LUMBER, TIMBER, PLYWOOD, GLUE-LAMINATED AND OTHER COMPOSITE LUMBER THAT IS IN CONTACT WITH CONCRETE OR MASONRY OR EXPOSED TO WEATHER SHALL BE PRESERVATIVE TREATED IN ACCORDANCE WITH CURRENT AMERICAN WOOD-PRESERVERS' ASSOCIATION (AWPA) PRESERVATIVE (P) STANDARDS. THESE MEMBERS SHALL BE TREATED WITH AN APPROVED PRESERVATIVE IN ACCORDANCE WITH CURRENT AWPA COMMODITY (C) STANDARDS AND THE AWPA USE CATEGORY SYSTEM (UCS). WHEREVER POSSIBLE, PRECUT ALL MATERIAL BEFORE TREATMENT. HANDLE TREATED LUMBER IN ACCORDANCE WITH AWPA M4 STANDARDS. FIELD CUTS, HOLES (SUCH AS ANCHOR BOLT HOLES IN TREATED SILL PLATES) AND PENETRATION DAMAGE SHALL BE TREATED IN ACCORDANCE WITH THE CURRENT AWPA M4 STANDARDS. THE MOST COMMONLY AVAILABLE PRESERVATIVE MEETING THE REQUIREMENTS OF STANDARD M4 IS A COPPER NAPHTHENATE SOLUTION CONTAINING AT LEAST 2% COPPER. CERTAIN DAP, WM BARR, CUPRINOL, BEHR, GREEN'S, JASCO, HENRY AND FIELDS PRESERVATIVE PRODUCTS CONTAIN THIS METAL CONTENT. ALL FASTENERS AND CONNECTORS IN CONTACT WITH PRESERVATIVE TREATED WOOD SHALL BE HOT-DIPPED GALVANIZED OR TYPE STAINLESS STEEL. SEE THE “WOOD CONNECTORS”SECTION. SCOPE OF STRUCTURAL ENGINEERING SERVICES THE STRUCTURAL ENGINEER HAS PERFORMED THE STRUCTURAL DESIGN AND PREPARED THE STRUCTURAL WORKING DRAWINGS FOR THIS PROJECT. THE CONSTRUCTION MUST BE PERFORMED IN STRICT ACCORDANCE WITH THE STRUCTURAL DRAWINGS. ANY DEVIATION FROM THE DRAWINGS MUST BE APPROVED IN WRITING BY THE STRUCTURAL ENGIN EER. ERRORS AND/OR OMISSIONS FOUND ON THE STRUCTURAL DRAWINGS MUST BE BROUGHT TO THE STRUCTURAL ENGINEER'S ATTENTION IMMEDIATELY. OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS OR THE INADVERTENT MISLABELING OF DETAILS OF WORK WHICH ARE MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR INADVERTENT MISLABELED DETAILS OF THE WORK BUT THEY SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. THE STRUCTURAL ENGINEER IS RESPONSIBLE FOR THE DESIGN OF THE PRIMARY STRUCTURAL SYSTEM. RESPONSIBILITY FOR ANY SECONDARY STRUCTURAL AND NON-STRUCTURAL SYSTEMS NOT SHOWN ON THE STRUCTURAL PLANS RESTS WITH SOMEONE OTHER THAN THE STRUCTURAL ENGINEER. THE STRUCTURE SHOWN ON THESE DRAWINGS IS STRUCTURALLY SOUND ONLY IN ITS COMPLETED FORM. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BRACING TO STABILIZE THE BUILDING DURING CONSTRUCTION. THE STRUCTURAL EN GINEER IS NOT RESPONSIBLE FOR, AND WILL NOT HAVE CONTROL OF, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE CONSTRUCTION WORK, NOR WILL HE BE RESPONSIBLE FOR THE CONTRACTOR'S FAILURE TO CARRY OUT THE CONSTRUCTION WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. GENERAL INSPECTIONS -CONCRETE CONSTRUCTION ELEMENT: REINFORCING STEEL PERIOD: BUILDING INSPECTOR SHALL INSPECT PER IBC 110 AND LOCAL AHJ REQUIREMENTS. ELEMENT: BOLTS IN CONCRETE, INCLUDING EMBEDDED BOLTS, AND EXPANSION AND EPOXY TYPE ANCHORS. PERIOD: BUILDING INSPECTOR SHALL INSPECT PER IBC 110 AND LOCAL AHJ REQUIREMENTS. GENERAL INSPECTIONS -WOOD FRAMING CONSTRUCTION ELEMENT: PLYWOOD SHEAR WALL AND ROOF AND FLOOR DECKING NAILING PERIOD: BUILDING INSPECTOR SHALL INSPECT PER IBC 110 AND LOCAL AHJ REQUIREMENTS. ELEMENT: SHEAR WALL HOLD-DOWNS TO FOOTINGS PERIOD: BUILDING INSPECTOR SHALL INSPECT PER IBC 110 AND LOCAL AHJ REQUIREMENTS. ELEMENT:BOLTS AND LAG SCREWS PERIOD: BUILDING INSPECTOR SHALL INSPECT PER IBC 110 AND LOCAL AHJ REQUIREMENTS. 2 / 11 / 2022 1. SEE GENERAL NOTES S1 FOR CONCRETE SPECS. 2. PROVIDE MINIMUM 18 INCH CRAWL SPACE UNDER WOOD JOISTS AND 12 INCHES UNDER WOOD BEAMS. 3. PROVIDE 14"x7" FOUNDATION VENTS WITH 1/4" CORROSION RESISTANT MESH INSTALL AT LEAST ONE VENT WITHIN 3' OF EACH CORNER. 4. CONTRACTOR TO COORDINATE SHEAR WALL ANCHOR BOLT AND HOLDOWN REQUIREMENTS WITH SHEAR WALL LAYOUT. 5. HOLDOWNS SHOWN ON THIS PLAN LEVEL TO BE INSTALLED AT TOP OF FOUNDATION WALL SILL PLATE. FOUNDATION NOTES: TOTAL CRAWL SPACE AREA: 435 SF VENT AREA REQUIRED: 435 / 300 = 1.45 SF VENT AREA PROVIDED: 4 * 0.51 = 2.04 SF (0.51 SQ. FT. NET VENT AREA PER VENT) INSTALL AT LEAST ONE VENT WITHIN 3' OF EACH CORNER CRAWL SPACE VENTS CALCULATION: ANCHORED BRACKET HOLD-DOWN SCHEDULE ATTACHMENT TO FOUNDATIONTAGMODEL MINIMUM END POST SIZE ATTACHMENT TO END STUDS HD1 (2)2x_ 1.MINIMUM SIZE OF POST AT THE END OF SHEARWALL, UNLESS NOTED OTHERWISE ON FRAMING PLANS. 2.ALL FASTENERS SPECS ARE FOR USE w/ HEM-FIR LUMBER. 3.ALL BRACKETS/STRAPS TO BE "SIMPSON STRONG-TIE" OR APPROVED EQUAL. REFER TO MFR'S INSTALLATION INSTRUCTIONS. 4. FOR ALL RETROFIT ANCHORS, MINIMUM SIDE EDGE DISTANCE = 13/4", MIMIMUM CORNER OR END WALL DISTANCE = 41/4". 1 (16) 0.148 x 3-1/4"8" EMBED"LSTHD8" (N) CRAWL SPACE 22' - 0"22' - 0"(N) 4x6 HF#2 CRAWL SPACE POST w/ 32" x 32" x 12" T SQUARE FOOTING, TOTAL OF (3) 8"20' - 8"8"8"20' - 10 1/2"6"21' - 6 1/2"(E) CRAWL SPACE 4' - 0 1/2"EXISTING RESIDENCE NEW ADDITION(E) CRAWL SPACE 8"10' - 4"10' - 4"8"2' - 0"8' - 4"8' - 4"2' - 0" (N) 4x12 HF#2 CRAWL SPACE FLUSH BEAM (N) 14"x7" VENTTOTAL OF (4)(N) 2x10 HF#2 @16"oc MAIN FLOOR JOISTS w/ "LUS28" HANGERS AT EACH END (N) 2x10 PT HF#2 LEDGER w/ 3/8"⌀x 5" "TITEN HD" ANCHORS @16"oc (N) 2x10 HF#2 @16"oc MAIN FLOOR JOISTS w/ "LUS28" HANGERS AT EACH END(N) PERIMETER 8" THICK STEM WALL &8" T x 16" W FOOTING w/ (2)#4 LONG. REBAR1 S4 2 S4 A4.1 3 (N) 2x10 PT HF#2 LEDGER w/ 3/8"⌀x 5" "TITEN HD" ANCHORS @16"oc S4 3 (E) FOUNDATION TO REMAIN REMOVE A SMALL PORTION OF (E) FOUNDATION WALL AS REQUIRED TO CONNECT (N) CRAWL SPACE UTILITIES CONTRACTOR TO COORDINATE SHEAR WALL ANCHOR BOLT AND HOLDOWN LOCATIONS WITH SHEAR WALL LAYOUT. S4 4HD1HD1 DATE: SHEET SIZE: DRAWING: 22" x 34"ENGINEERED STRUCTURESGLOBAL DESIGN, PLLCDRAWINGS PROVIDED BY: !" # $ %&’()%*)&%+,2-$-2 1/26/2022 6:42:11 PMS2ADDITIONFOUNDATION /MAIN FLOORFRAMING PLAN2/6/2022KAIWI ADDITION4114 NE 2ND ST,RENTON, WA 980591/4" = 1'-0" ADDITION FOUNDATION / MAIN FLOOR FRAMING PLAN 2 / 11 / 2022 A4.1 3 1. SEE GENERAL NOTES S1 FOR FLOOR AND WALLS SHEATING AND NAILING. 2. ALL NEW EXTERIOR WALL STUDS TO BE 2x6. 3. ALL NEW INTERIOR WALL STUDS TO BE 2x4. 4. ALL DIMENSIONES ARE TO FACE OF WALL STUDS, FACE OF CONCRETE WALLS, OUTSIDE DECK FRAMING, CENTER OF POSTS, CENTER OF BEAMS, UNO. 5. TYPICAL INTERIOR AND EXTERIOR WALL HEADER TO BE MINIMUM (2)2x8 UNO ("HDR"). 6. WINDOW AND DOOR HEADERS SHALL BE INSULATED WITH A MINIMUM OF R-10 INSULATION. 7. ALL WOOD POSTS CALLED OUT ON PLANS SHALL CARRY DOWN TO FOUNDATION, UNLESS CARRIED BY BEAM. 8. ALL BEAM-POST CONNECTIONS TO HAVE METAL BRACKET TIES. 9. PROVIDE SOLID JOIST BLOCKING BELOW ALL CROSS WALLS. 10. SHEAR WALLS, WHERE INDICATED ON PLAN, SHALL BE FRAMED PER SHEAR WALL SHCEDULE S3 11. CONTRACTOR TO COORDINATE SHEAR WALL ANCHOR BOLT AND HOLDOWN REQUIREMENTS WITH SHEAR WALL LAYOUT. 12. COORDINATE AND PROVIDE BACKING FOR MILLWORK AND ITEMS ATTACHED OR MOUNTED TO WALLS OR CEILINGS. FRAMING NOTES:FRAMING PLAN LEGEND: SHEAR WALL TAG, (REFER TO SHEAR WALL SCHEDULE) HOLD-DOWN TAG, (REFER TO HOLD-DOWN SCHEDULE) A HD1 NEW SHEAR WALL EXISTING WALL TO BE UPGRADED OR VERIFIED SHEAR WALL INSTALLATION NOTES: 1.INSTALL WALL SHEATHING PANELS EITHER HORIZONTALLY OR VERTICALLY 2.SHEAR WALLS WITH WINDOW OPENINGS INCLUDED IN THEIR LENGTH ARE DESIGNED AS "PERFORATED WALLS." PROVIDE SHEAR WALL SHEATHING AND NAILING FOR ENTIRE LENGTH & HEIGHT OF WALLS AS INDICATED ON THE PLANS. SEE PLANS FOR HOLDOWN REQUIREMENTS 3.SHEATHING EDGE NAILING IS REQUIRED AT ALL HOLDOWN POSTS. EDGE NAILING MAY ALSO BE REQUIRED TO EACH STUD USED IN BUILT-UP HOLDOWNS POSTS. REFER TO HOLDOWN MANUFACTURER'S INSTALLATION DETAILS FOR ADDITIONAL INFORMATION 4.BLOCKING IS REQUIRED AT ALL PANEL EDGES. 5.INTERMEDIATE FRAMING TO BE WITH 2x MINIMUM MEMBERS. FIELD NAILING 12"oc 6.BASED ON 0.131"⌀x 11/2" LONG NAILS USED TO ATTACH SHEAR CLIPS DIRECTLY TO FRAMING. USE 0.131"⌀x 21/2" NAILS WHERE INSTALLED OVER SHEATHING 7.SHEAR CLIPS: SIMPSON "RBC" OR "LTP4" OR APPROVED EQUIVALENT 8.ANCHOR BOLTS SHALL BE PROVIDED WITH STEEL PLATE WASHERS 1/4" x 3" x 3". EMBED ANCHOR BOLTS 7" MINIMUM INTO THE CONCRETE 9.CONTACT THE ENGINEER OF RECORD FOR ADHESIVE OR EXPANSION BOLT ALTERNATIVES TO CAST-IN-PLACE ANCHOR BOLTS 10.PRESSURE TREATED MATERIAL CAN CAUSE EXCESSIVE CORROSION IN THE FASTENERS. PROVIDE HOT-DIPPED GALVANIZED (ELECTRO-PLATING IS NOT ACCEPTABLE) NAILS AND CONNECTOR PLATES (FRAMING ANGLES, ETC) FOR ALL CONNECTORS IN CONTACT WITH PRESSURE TREATED FRAMING MEMBERS 11.(SPECIAL INSPECTION MAY BE REQUIRED) SHEAR WALL SCHEDULE (ALL FASTENER SPACING ARE FOR USE WITH DOUGLAS FIR MATERIAL) LABEL APA RATED SHEATHING NAIL SIZE AND SPACING AT EDGES STUD AND BLKG SIZE AT ADJOINING EDGES TOP PLATE ATTACHMENT TO ROOF ABOVE SILL PLATE ATTACHMENT (1)(2) (3)(4) (5) (6) (7) ANCHOR BOLT TO CONCRETE (9) SILL PLATE SIZE AT FOUNDATION (10) 7/16" ONE SIDE 8d AT 6" oc 2x "RBC" CLIP @12"oc 5/8"⌀AB AT 48" oc 2x NAIL SPEC: 8d = 0.131"⌀ 10d = 0.148"⌀ 16d =0.162"⌀ A TOP PLATE ATTACHMENT TO FLOOR ABOVE (7) (8) "LTP4" CLIP @18"oc BOTTOM PLATE ATTACHMENT NAILING TO WOOD BELOW 16d AT 6" oc 3" / 12" ROOF SLOPE (N) RIDGE3" / 12" ROOF SLOPE (N) HDR (N) HDR(N) ROOF TRUSSES @24"oc PER MANUFACTURER 1' - 6"3' - 2"5' - 0"2' - 10"2' - 10"5' - 0"3' - 2"1' - 6" 12' - 6"12' - 6" 25' - 0"3' - 2"3' - 0"15' - 4 1/2"1' - 6"21' - 6 1/2"1' - 6"1' - 6"18' - 6 1/2"3' - 0"1' - 11 1/2"1' - 0"1' - 0"22' - 0"1' - 6"EXISTING RESIDENCE NEW ADDITION(E) UPPER FLOOR JOISTS TO REMAIN (N) HDR24' - 6"A A A A 4' - 0 1/2"1' - 6" 5' - 6 1/2" 7 S5 8 S5 9 S5 HD1HD1(N) HDR (N) HDR (E) SHEARWALL TO REMAIN(E) HDR TO REMAIN (E) SHEARWALL TO REMAIN (E) HDR(E) HDR 1' - 0"11' - 2"11' - 2"2' - 1 1/2"1' - 7"1' - 0"5' - 0"7' - 0"1' - 6"14' - 6"(N) 4x10 HF#2 PATIO ROOF BEAM(N) "SKYLIFT" RISER "SK18-B 3.5" SUPPORTING (N) PATIO ROOF BEAM ABOVE (E) HOUSE WALL, PROVIDE (N) 4x4 HF#2 POSTS AT (E) WALL UNDER (N) SKYLIFT RISERS LOCATIONS, TOTAL OF (3) 1' - 0"10' - 6 1/2"10' - 6"1' - 0"(N) 2'x4' SKYLIGHT(N) 2'x4' SKYLIGHT(N) 2'x4' SKYLIGHT3" / 12"6' - 2 1/2"5' - 11 1/2"5' - 11 1/2"4' - 11" 24' - 0" 8" (N) 2x8 HF#2 @24"oc PATIO ROOF RAFTERS (N) 4x10 HF#2 PATIO ROOF BEAM (N) PT 6x6 HF#2 PATIO ROOF POST w/ 48"x30" CONC. FOUNDATIONS TOTAL OF (3) S5 13 S5 12 S5 14 (N) 2x8 LEDGER AT (E) WALL, ATTACH w/ (N) (2)3-5/8" "LEDGER-LOK" SCREWS AT 16"oc (AT EACH WALL STUD) PROVIDE (N) "LSTA24" STRAP (N) BEAM TO (N) LEDGER DATE: SHEET SIZE: DRAWING: 22" x 34"ENGINEERED STRUCTURESGLOBAL DESIGN, PLLCDRAWINGS PROVIDED BY: !" # $ %&’()%*)&%+,2-$-2 1/26/2022 6:42:11 PMS3ADDITION ROOFFRAMING PLAN2/6/2022KAIWI ADDITION4114 NE 2ND ST,RENTON, WA 980591/4" = 1'-0" ADDITION ROOF / PATIO ROOF FRAMING PLAN 2 / 11 / 2022 1' - 6"6" CONC. STEM WALL PER PLAN #4 @12" oc HORIZONTAL 6 MIL POLYTHYLENE GROUND COVER, 6" MIN. LAP CONC. FOOTING w/ REBAR PER PLAN WALL SHEATHING PER SHEAR WALL SCHEDULE T&G PLYWOOD PER STRUCTURAL NOTES 2x6 STUDS @16" oc FLOOR JOIST w/ HANGER PER FRAMING PLAN PT LEDGER w/ ANCHORS PER FRAMING PLAN, STAGGER 1" FROM CENTER 4" PERF. FOOTING DRAIN w/ 4" LAYER OF GRAVEL AROUND CONNECT TO (E) FOOTING DRAIN OR TO SUITABLE DRAINAGE DISCHARGE LOCATION FINISHED GRADE 6" MIN.1' - 6" MIN.(12" UNDER BEAMS)18" MIN.PER PLAN SIZE3" CLRPT 2x6 SILL PLATE w/ A.B. PER SHEAR WALL SCHEDULE (2)#4 CONT. TOP #4 @18" oc VERT. w/ HOOK, ALT. DIRECTION (N) 6 MIL POLYTHYLENE GROUND COVER, 6" MIN. LAP (N) T&G PLYWOOD PER STRUCTURAL NOTES (N) FLOOR JOIST w/ HANGER PER FRAMING PLAN (N) PT LEDGER w/ ANCHORS PER FRAMING PLAN (12" UNDER BEAMS)18 3/4" MIN.(E) FOOTING TO REMAIN (E) CONC. STEM WALL TO REMAIN (E) RESIDENCE FLOOR TO REMAIN (E) EXTERIOR WALL w/ SHEATHING TO REMAIN (12" UNDER BEAMS)18" MIN.12"FLOOR JOISTS w/ HANGERS PER FRAMING PLAN T&G PLYWOOD PER STRUCTURAL NOTES SQUARE CONCRETE FOOTING PER PLAN SIZE PER PLAN (4)#4 HOR. REBAR EACH WAY 3" CLRFLUSH CRAWL SPACE BEAM PER FRAMING PLAN SIMPSON "PC4Z" POST CAP AT EACH POST CRAWL SPACE POST PER PLAN SIMPSON "ABU46" POST BASE w/ 5/8" DIA x5" EMBED SS-WEDGE ANCHOR 6 MIL POLYTHYLENE GROUND COVER, 6" MIN. LAP (2)2x_ STUDS MIN PANEL-EDGE NAIL PLWD SHEATHING TO EACH STUD (STAGGER) EMBED HOLDOWN STRAP SEE FOUNDATION PLAN FOR SIZE AND LOCATIONS #5 x 36" REBAR CENTER ON STRAP EMBED FOUNDATION STEM WALL WOOD SHEARWALL P.T. SILL PLATE w/ ANCHORS PER SHEAR WALL SCHEDULE PT WOOD SILL PL PER PLAN AND DETAILS 6" MIN TO 12" MAX AT EACH END OF EACH SILL PL SEGMENT (MIN 2 BOLTS PER SEGMENT) 5/8"⌀A.BOLTS w/ 3"x3"x1/4" PL WASHERS SPACING PER SHEARWALL SCHEDULE (MAX 60" WHERE NOT AT SHEARWALL) BOT PL (USE 3x WHERE REQD IN SHEARWALL SCHED) BLKG REQD AT ALL PANEL EDGES (USE 3x WHERE REQD IN SHEARWALL SCHED NAIL PANEL FIELD AT 12" oc EDGE NAILING PER SHEARWALL SCHED. PLWD SHTG W/ FACE GRAIN PERPENDICULAR OR PARALLEL TO STUDS DOUBLE 2X PLATE STUDS (USE 3x STUD AT PANEL EDGES WHERE REQD IN SHEARWALL SCHED) DATE: SHEET SIZE: DRAWING: 22" x 34"ENGINEERED STRUCTURESGLOBAL DESIGN, PLLCDRAWINGS PROVIDED BY: !" # $ %&’()%*)&%+,2-$-2 1/26/2022 6:42:11 PMS4STRUCTURALDETAILS2/6/2022KAIWI ADDITION4114 NE 2ND ST,RENTON, WA 980593/4" = 1'-0" (N) ADDITION FOUNDATION / MAIN FLOOR FRAMING DETAIL1 3/4" = 1'-0" (N) ADDITION FLOOR LEDGER CONNECTION DETAIL2 3/4" = 1'-0" (N) ADDITION MAIN FLOOR FRAMING DETAIL3 3/4" = 1'-0" TYP HOLD-DOWN AT NEW FOUNDATION4 3/4" = 1'-0" TYP ANCHOR BOLT LAYOUT5 3/4" = 1'-0" TYP ONE STORY SHEARWALL DETAIL6 2 / 11 / 2022 PLATELINEWALL SHEATHING PER SHEAR WALL SCHEDULE 2x STRUCTURAL FASCIA ROOF SHEATHING w/ NAILING PER STRUCTURAL NOTES VENTED BLOCKING PER TRUSS MANUFACTURER 8d @4"oc FASTENMASTER "TIMBER-LOK" 6" SCREW AT EACH TRUSS INSTALL PER MANUFACTURER ROOF TRUSSES PER MANUFACTURER 2x6 STUDS @16" oc (2)2x6 TOP PLATE SIMPSON "LUS26" HANGER GIRDER TRUSS PER MANUFACTURER 8d @4"oc PERIMETER ZONE 2x STRUCTURAL FASCIA ROOF SHEATHING w/ NAILING PER STRUCTURAL NOTES 2' MAX. 2x BLOCKING MIN 2x6 OUTLOOKER GABLE END TRUSS PER MANUFACTURER SIMPSON "LTP4" @48"oc WALL SHEATHING PER SHEAR WALL SCHEDULE (N) FASTENMASTER "FLATLOK 3-1/2in" @32"oc SCREWS TRUSS TOP CHORDS TO WALL STUDS, REMOVE (E) SIDING AS REQUIRED BEFORE INSTALLATION (E) 2x STUDS @16"oc VERIFY 8d @4"oc SHEATHING TO LEDGER (N) COMMON ROOF TRUSSES PER MANUFACTURER (N) ROOF SHEATHING w/ NAILING PER STRUCTURAL NOTES (N) END ROOF TRUSS PER MANUFACTURER (N) GALVANIZED STEEL L FLASHING (2)2x6 BEARING STUDS (TYP U.N.O) HEADER (PER PLAN) CRIPPLE STUDS @12"oc (1)2x6 KING STUD (TYP U.N.O) (4) 16d FACE NAIL PER ARCH T/O PLATE (2)2x6 TOP PLATE (8) 16d NAILS EACH SIDE OF EACH JOINT (8) 16d NAILS EACH SIDE OF EACH JOINT 2x6 EXTERIOR WALL STUDS (2)2x6 TOP PLATE 4'-0" MIN PT PATIO ROOF POST PER PLAN 2x BLOCKING BETWEEN RAFTERS SIMPSON "H2.5" CLIP @24"oc BEAM TO RAFTER PATIO ROOF RAFTERS PER PLAN PATIO ROOF BEAM PER PLAN SIMPSON "CCQ46" POST CAP AT EACH PATIO ROOF POST (N) PATIO ROOF ASSEMBLY ASPHALT SHINGLE ROOFING #15 FELT PAPER ROOF SHEATHING PER STRUCTURAL NOTES SIMPSON "H2.5" CLIP @24"oc BEAM TO RAFTER (E) VENTED BLKG BETWEEN RAFTERS AT SKYLIFT RISER LOCATION TO BE REBUILT (E) RESIDENCE ROOF RAFTERS TO REMAIN (E) ROOF SHEATHING TO REMAIN PROVIDE (N) 4x4 HF#2 POSTS AT (E) WALL UNDER "SKYLIFT" RISER LOCATIONS (E) RIM JOIST TO REMAIN ADD SOLID 2x BLOCKING UNDER (N) POST (E) EXTERIOR WALL FOUNDATION TO REMAIN (E) WALL SHEATHING TO REMAIN (N) PATIO ROOF RAFTERS PER PLAN (N) 2x BLOCKING BETWEEN RAFTERS 2x PT FASCIA BOARD (N) (8)1/4" DIA. SIMPSON SDS WOOD SCREWS "SKYLIFT" RISER TO (E) WALL TOP PLATE EMBED 2" MIN. SKYLIFT RISER "SK18-B 3.5"1' - 6"(N) PIPE FLASHING PER MANUFACTURER (N) PATIO ROOF BEAM PER PLAN TOENAIL (N) 4x4 POST TO (E) SILL PLATE w/ (4)16d (E) RESIDENCE FLOOR TO REMAIN (N) PATIO ROOF ASSEMBLY ASPHALT SHINGLE ROOFING #15 FELT PAPER ROOF SHEATHING PER STRUCTURAL NOTES 10d @6" oc, TYP 6x6 PT POST SIMPSON "MPB66Z" POST BASE (5)#5 BARS HORIZONTAL 18" DIA CONCRETE PLINTH. DOWEL INTO FOOTING w/ (4)#4 VERT BARS#4 HORIZONTAL TIES AT 3"oc (SQUARE SHAPE) (4)#5 BARS HORIZONTALSIZE PER PLAN 1' - 0"1' - 0"CONCRETE FOOTING PER PLAN 4" THICK CONCRETE PATIO SLAB w/ REINF. PER STRUCTURAL NOTES DATE: SHEET SIZE: DRAWING: 22" x 34"ENGINEERED STRUCTURESGLOBAL DESIGN, PLLCDRAWINGS PROVIDED BY: !" # $ %&’()%*)&%+,2-$-2 1/26/2022 6:42:11 PMS5STRUCTURALDETAILS2/6/2022KAIWI ADDITION4114 NE 2ND ST,RENTON, WA 980593/4" = 1'-0" (N) ROOF TRUSSES FRAMING DETAIL7 3/4" = 1'-0" GABLE END TRUSS FRAMING DETAIL8 3/4" = 1'-0" END ROOF TRUSS ATTACHMENT DETAIL9 3/4" = 1'-0" TYP DROPPED HEADER DETAIL10 3/4" = 1'-0" TYP TOP PLATE SPLICE DETAIL11 3/4" = 1'-0" (N) PATIO ROOF FRAMING DETAIL12 3/4" = 1'-0" (N) PATIO ROOF ATTACHMENT ABOVE (E) HOUSE WALL143/4" = 1'-0" (N) PATIO ROOF POST FOUNDATION DETAIL13 2 / 11 / 2022