Loading...
HomeMy WebLinkAboutR-406332M CD CD _J _J LLJ m Q Q N O N c.� i rn 00 i U) 0 / Q0 m 00 / V) O O O 00 w I I WALL ELEVATIONS TW = TOP OF WALL I I FF 30.77 RECORD GRADING PLAN - NORTH FOR CHICK=FIL=A RENTON SECTION 18, TWP. 23 N., RGE 5 EAST, W. M. CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON CMU SCREENWALL NOTES: ACCESSIBLE PATH OF TRAVEL NOTE: WALKWAYS ALONG ACCESSIBLE ROUTES OF TRAVEL SHALL BE CONTINUOUSLY ACCESSIBLE, A MINIMUM 48" IN WIDTH, HAVE A MAXIMUM 1.5% CROSS SLOPE, AND SHALL HAVE RAMPS COMPLYING POWER EASEMENT LANDING COMPLIANT. ELEVATIONS v/ I I WITH ADA STANDARDS (SECTION 405) WHERE NECESSARY TO TW= xxx.xx X X KC REC NO. 9410201209 AND SLOPES SHOWN FOR CHANGE ELEVATION AT A LONGITUDINAL SLOPE EXCEEDING 5% BG= xxx.xx REFERENCE ONLY. / ° (1:20). A CONTINUOUS 36" WIDE DETECTABLE WARNING STRIP O 30.70 - SET TOP OF CURB 6" I MEETING ADA STANDARDS (SECTION 406.8) SHALL BE PLACED DIFFERENCE IN - _ _ _ ABOVE ADJACENT 4 WHERE A WALK CROSSES OR ADJOINS A VEHICULAR WAY AND IS ELEVATIONS I ---�� PAVEMENT AND v . D NOT SEPARATED BY A CURB, RAILING, OR OTHER ELEMENT MEETING BG=FINISHED GRADE I ° ° a° °=�7/ EXPOSED CURB BACK v ' ADA STANDARDS. ELEVATION \ � 30.27 _ _ _ _ _ 10' GAS EASEMENT Z GRADE AREA TO DRAIN / - _ N77'26 4 KC REC. NO. 20130411001089 TW O` �0.7 30.27 36.27 / 29.80 2 E 167.42' 30. 5 EX v 30.66 EX >t C+. T30.7 t ME SPOT ELEVATION NOTES: J0.72 30.14 / D 0.70 / _ _ _ _ _ _ _ _ 30.14± FL ME rn ALL SPOT ELEVATIONS SHOWN ARE TO FINISHED SURFACE (TOP OF -------- BG � a 7 I ° 30.64± TC ME ASPHALT OR TOP OF CONCRETE PAVEMENT) UNLESS OTHERWISE 3 .66 . 7.509' 3 .27 ° v a 29.50 `� - _ P 1.22% 17 Z NOTED. 0.64 30.2 30.11 ----- 30.1�6 ��` 30.8 C BG - GRADE AT BOTTOM OF EXPOSED WALL % 7 F WALL 30.1 1 ± FL ME COL-TTOP OP OOF FOOTING COLUMN WALL BURY DEPTH PER i 1.5 %' 30.21 FC � � � � �'�`� I '1.509' 30.28 TC � TA =TOP OF ASPHALT ADJACENT TO CURB/SIDEWALK STRUCTURAL PLANS. I I ,1., �o TC TOP OF CURB/SIDEWALK ADJACENT TO ASPHALT FOOTINGS SHALL BEAR ON I 30.40 30.14 0�°� d a �,, 2.26� 29.19 \30.4 TP - TOP OF PAVEMENT IMPROVED SOIL MINIMUM PER O I z FC - FLUSH CURBING ADJACENT TO PAVEMENT STRUCTURAL PLAN NOTES. _ _ _ ° a a w wl v ME - MATCH EXISTING 30.84�q� + GB - GRADE BREAK 30.03_ FL ME PL - TOP OF PLANTER/RAISED TAPERED PLANTER WALL 1 I D 1 30.19 I I I 1 / of 30.20 TC 1 29.53 / �I 1.50%Q 0 I 26.90 30.23 30.27 1 �1I �' i p 30.35 9.98± FL ME EXISTING UTILITY LIDS: / 30.15 TC i v ALL EXISTING UTILITY STRUCTURE LIDS THAT FALL WITHIN THE AREA 1CbdW00 �� 1CddWOC� 1CddWOC 10`ddWO 1CbdW00 /�1CbdW00 d 30.23± ME OF WORK SHALL BE ADJUSTED TO FINISHED GRADE ELEVATIONS. ` I .�tK i 29.76 SET TOP OF CURB) 30.89 =w ° _ _ _ _ CONTRACTOR SHALL CONFIRM THE FEASIBILITY OF ADJUSTING 1 i 30.24 �, 29.42 I I 6" ABOVE ADJACENT L 4 ' EXISTING UTILITY STRUCTURE LIDS TO FINISHED GRADE PRIOR TO I � � 30.11 I � 1 � 30.85 M SEWER EASEMENT 0 i I W i PAVEMENT ,� v 29.95± FL M 30.20± ME CONSTRUCTION AND NOTIFY ENGINEER OF ANY DISCREPANCIES. p P 1 10 W00 30.12 TC IY REC N0. 5253595 I i� �� 30.28 _ _ _ _ _ _ _ - _ _ _ 59% . I n I 2 .99 i '� I I ` 30.44 �� I 29.59 I I 31. 0 / 30.15 a �� �i 30.0� �` 29 59 i '� 4sg i 31.0 'I 30.26 �. I '` 29.90± FL ME UTILITY PROTECTION NOTE: 1 1 0 _ _ _ _ _ _ 30.77 I CONTRACTOR SHALL UTILIZE ANY MEASUREMENTS NECESSARY TO 1 29 93 ♦` 30.45 31.12 1.48% PROTECT EXISTING UTILITIES THAT MAY BE IMPACTED BY 1 1 29 85+ FL ME SET TOP OF CURB 6" 30.1 1 I _ _ _ _ _ _ 1 ^ o q OVEREXCAVATION NOTED IN GEOTECHNICAL REPORT 1 1.51 % 1 30. 5± TC ME ABOVE ADJACENT I _ _ _ _ _ 31.06 1 ° a 1.26% §.7 I 29 89 30.4�1 + 4 PAVEMENT AND 1.50% �� EXPOSED CURB BACK i 30.15 �` v . a 29.74 a I ��� ° \ 30.87 301.53± ME 0 TP=- 30.08 TP= 29.88 TP= 29.78 I 2 2 _ _ 0 I 1 / COL= 27.78 COL = 27.78 aj COL= 27.78 1 .750% 30.37 / 0 29.90 ,' L 29.79± FL ME 9.89 ' C v p. TW= 34.05 30. 0 30.29± TC ME 30.05± ME 74 i J �� v / '� 30.19 BG= 30.99 ------ 29.58 /� a o �. / `" v 4 v / a a v TW= 34.05 v 1.50%Q v - -� ° BG= 30.94 I 0.31 ± MEN' ' 30.01 ± ME _ a a �� 2�.92. �r 29.95 ° 29.19± FL ME 0 / 1 / TP= 30.11 TP= 29.94 TP= 29.88 I 4 `� 4130.28 J - - - - - 30.29± TC ME / 29.47 / COL= 27.78 COL= 27.78 ICOL= 27.78 i0' 0 30.58 EXISTING SIDEWALK IS ADA M % i v �� ° a ° 4 T 30.44+ ME I 29.79± FL ME I LANDING COMPLIANT. ELEVATIONS 10' GAS EASEMENT _ - KC REC N0. 20130411001089 ; c, 30.20 Q TA v 30.29± TC ME AND SLOPES SHOWN FOR -4-L SLOPES & UTILITIES EASEMENT REFERENCE ONLY. - -� PER 20110620001119 EXISTING SIDEWALK IS ADA �II ------- - - - - -- 30.0 /IIII / 3-1O ----------- --------I � 1d 30.430.24a a. 29.77 29.54 30.58 N/v 4 crt 'I SLOPES & UTILITIES EASEMENT .� 29.99 . KC REC NO. 20110811001003 30.89 TC 30.96 I a rn v l 29.35 0 0 1 M zo ° I L0 do N I 30.37 II \ 3035 30.58 1 30.55 . I � 1 29. 6 30' 30.24 1 30.5 a I 1 1 / TW= 34.05 O II 1 1 30.45 TA / 1 56% 61 % - - ' 30.95 TIC / i BG= 31.05 1 I o 1 Ln I Y1.38% 1 11 TA 11 0 30.25 w 1 ° o k CMU SCREENWALL WITH STUCCO FINISH I 30.�� 30.50 TA b\ m ?'!u''.P',, 30.50 TIC t° PER STRUCTURAL PLANS. FOOTINGS SHALL BEAR ON IMPROVED SOIL 18' MIN PER STRUCTURAL PLAN 1 a RIDGE LINE 1_ _ RIDGE LINE_ ° \ 1 a 29.90± ME NOTES. TOP OF FOOTING = 29.38 CONTRACTOR TO ° v 1 29.74 30.53 v a TA l CONFIRM BURY REQUIREMENTS WITH STRUCTURAL 1 c� RIDGE LINE (AT MATCH LINE) v �31r? ITC 30.00_ ME PLANS PRIOR TO CONSTRUCTION AND ADJUST AS ----- - - - - -- ------- ----- - - ---------- GEOTECHNICAL RECOMMENDATIONS MATCH LINE SEE SHEET C4.1 GRADE BREAK NECESSARY. THE INFORMATION BELOW IS TAKEN FROM THE GEOTECHNICAL ENGINEERING REPORT PREPARED BY TERRACON CONSULTANTS, INC. DATED JUNE 21, 2018 AND IS FOR REFERENCE PURPOSES ONLY. CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEWING AND COMPLYING WITH ALL RECOMMENDATIONS OUTLINED IN THE GEOTECHNICAL REPORT. 1. POSSIBLE STATIC SETTLEMENTS AND LIQUEFACTION IN THE EVENT OF AN EARTHQUAKE IS PRESENT. IT IS RECOMMENDED THAT THE BUILDING BE SUPPORTED ON SMALL DIAMETER (PIN) PILES OR THAT GROUND IMPROVEMENT SUCH AS AGGREGATE PIERS BE UTILIZED TO IMPROVE FOUNDATION SOILS. 2. OVER -EXCAVATION SHOULD EXTEND TO 2 FEET BELOW THE BOTTOM OF THE PAVEMENT SECTION. GEOTEXTILE (MIRAFI 50OX) SHOULD BE PLACED DIRECTLY ON SUBGRADE TO PROVIDE SEPARATION BETWEEN THE SOFT SUBGRADE AND STRUCTURAL FILL. PLACE AND COMPACT 2 FEET OF STRUCTURAL FILL ABOVE THE GEOTXTILE. 3. ALL GRADES MUST PROVIDE EFFECTIVE DRAINAGE AWAY FROM THE BUILDING DURING AND AFTER CONSTRUCTION. Barghausen Consulting Engineers, Inc. 18215 72nd Avenue South Kent, WA 98032 425.251.6222 barghausen.com No. POWER EASEMENT KC REC. N0. 9410201209 Know what's below. PROVIDE 15" D.I. SLEEVE ® OU Call before di FOR PIPE UNDER WALL'S O Y g• ZONE OF INFLUENCE 1 Dial811 R-406337 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Q � z ,p 47671 O NALTEF.�G\�� SURVEYED: RLH SCALE: �- , 1 -10 VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 CITY O F %R 1; 0 o RECORD GRADING P LAN NORTH 12/19/2019 DESIGNED: JC FIELDBOOK: RENTON 0• 1i , FOR i/ PAGE: DRAWN: CMS DRAWING N0: C4.0 ONE INCH Planning/Building/Public Works Dept. CHICK-FIL-A RENTON ® 375 RAINIER AVE S RENTON WA f 98055 AS -BUILT PLANS MM 3/15/21 CRJ CHECKED: AEM AT FULL SCALE IF NOT ONE INCH REVISION BY DATE APPR SCALE ACCORDINGLY STORE NO.. 04249 APPROVED: CRJ SHEET: 5 OF: 24