HomeMy WebLinkAboutR-406339_J
_J
LLJ
m
Q
7E
Q
N
(D
N
7p
Q
i
rn
co
i
u)
0
/
rn
O°
i
0
0
0
00
w
® SITE DEVELOPMENT NOTES:
1.
PROPOSED
CHICK-FIL-A RESTAURANT. SEE ARCHITECTURAL PLANS.
2.
PROPOSED
ASPHALT PAVEMENT. SEE DETAIL 21/C11.2.
3.
PROPOSED
CONCRETE PAVEMENT DRIVE-THRU. SEE DETAIL 25/C11.2.
4.
PROPOSED
SPILLING CURB AND GUTTER (TYP). SEE DETAIL 17/C11.1.
5.
PROPOSED
BARRIER CURB (TYP). SEE DETAIL 5/C11.4.
6.
PROPOSED
ADA COMPLIANT SIDEWALK ACCESSIBLE RAMP. SEE DETAIL 7/C11.0.
7.
PROPOSED
TRASH ENCLOSURE. SEE ARCHITECTURAL PLAN FOR TRASH ENCLOSURE DETAILS.
8.
PROPOSED
BOLLARD WITH MOUNTED ADA ACCESSIBLE PARKING SIGN. SEE DETAIL 6/C11.0.
9.
PROPOSED
ON -SITE CONCRETE SIDEWALK. SEE DETAIL 11 AND 12/C11.0.
10.
PROPOSED
DIRECTIONAL PAVEMENT MARKINGS (TYP). SEE DETAIL 1 AND 2/C11.0 AND 32/C11.3.
11.
PROPOSED
SIGN. SEE SIGN PLAN.
12.
PROPOSED
4" WIDE WHITE REFLECTIVE PAINT PARKING STALL STRIPES PER PAINT STRIPING PROJECT
SPECIFICATIONS
(TYP).
13.
PROPOSED
LANDSCAPING PER LANDSCAPE AND IRRIGATION PLANS.
14.
SAWCUT IN
A SMOOTH CONTINUOUS LINE (TYP).
15.
PROPOSED
18" STEP OFF CURB (TYP). SEE DETAIL 4/C11.4.
16.
PROPOSED
ADA STALL STRIPING AND MARKING. SEE DETAIL 4 AND 5/C11.0.
17.
PROPOSED
CONCRETE SECTION AND APRON FOR TRASH ENCLOSURE. SEE DETAIL 24/C11.2.
18.
PROPOSED
ORDER POINT STRIPING. SEE DETAIL 27/C11.2.
19.
PROPOSED
BIKE RACK. SEE ARCHITECTURAL PLANS.
20.
PAVEMENT
EDGE. SEE DETAIL 21A/C11.2.
21.
PROPOSED
FLAG POLE. SEE SEPARATE SIGN PLANS FOR ADDITIONAL DETAILS.
22.
DRIVE-THRU ORDER POINT ISLAND CURB. SEE DETAILS 34/C11.3.
23.
PROPOSED
DRIVEWAY MODIFIED FROM RENTON STANDARD PLAN 104.4. CONSTRUCT DRIVEWAY CURB
PER CITY OF RENTON STANDARDS AND TIE INTO EXISTING CURB. MATCH EXISTING ELEVATIONS AT
CURB TIE
IN. SEE DETAIL 3/C11.4 FOR SLOPING AND CURB REQUIREMENTS. DRIVEWAY CONSTRUCTION
TO BE COMPLETED DURING CITY APPROVED TIME. COORDINATE APPROVED WORK HOURS AND
RESTRICTIONS WITH THE CITY PRIOR TO CONSTRUCTION.
24.
PROPOSED
HEIGHT CLEARANCE ARM. SEE SIGN PLANS.
25.
PROPOSED
CONCRETE V-SWALE. SEE DETAIL 6/C11.4.
26.
PROPOSED
STRUCTURAL COLUMN AND SCREEN WALL. SEE ARCHITECTURAL PLANS.
27.
PROPOSED
MENU BOARDS. SEE ARCHITECTURAL PLANS.
28.
PROPOSED
BOLLARD. SEE DETAIL 20/C 1 1.1.
29.
PROPOSED
OFF -SITE SIDEWALK PER CITY OF RENTON STANDARD PLAN 102. SEE DETAIL 1/C11.4.
30.
PROPOSED
OFF -SITE CURB PER CITY OF RENTON STANDARD PLAN 101. MATCH EXISTING ELEVATIONS
AT CURB TIE IN. SEE DETAIL 2/C11.4.
31.
NOT USED.
32.
DRIVE-THRU ORDER POINT CANOPY, SEE ARCHITECTURAL PLANS.
33.
PROPOSED
TRANSFORMER. SEE SHEET C10.0 FOR ADDITIONAL DETAIL.
34.
PROPOSED
BENCH LOCATION, SEE LANDSCAPE PLAN SHEET L5.
35.
PROPOSED
ADA NO PARKING SIGN. SEE ARCHITECTURAL PLANS.
36.
PROPOSED
PERVIOUS CONCRETE SIDEWALK. SEE SHEET C5.0 FOR ADDITIONAL DETAIL.
37.
PROPOSED
CANOPY STRUCTURAL COLUMN (TYP). SEE ARCHITECTURAL PLANS.
38.
PROPOSED
PLAZA AREA. SEE ARCHITECTURAL AND LANDSCAPE PLANS.
39.
PROPOSED
CONCRETE STEPS, SEE GRADING PLAN FOR DESIGN INFORMATION AND ELEVATIONS, SHEET
C4.1 AND
SEE LANDSCAPE PLAN SHEET L5 FOR DETAILS.
40.
PROPOSED
CMU SCREEN WALL WITH STUCCO FINISH, SEE GRADING PLAN FOR DESIGN ELEVATIONS,
SHEETS C4.0 AND C4.1. SEE STRUCTURAL PLANS FOR DETAILS.
41.
PROPOSED
LOT LIGHT. SEE SEPARATE LIGHTING PLAN.
42.
NOT USED.
43.
PROPOSED
MONUMENT SIGN. SEE SEPARATE SIGN PLAN FOR ADDITIONAL DETAILS.
44.
CONTRACTION JOINTS IN CONCRETE (TYP), SEE DETAIL 28/C11.2. CONTRACTION JOINTS SHALL BE
SPACED AT
12' MAX. ALIGN DRIVE-THRU CONTROL JOINTS WITH CURB CONTROL JOINTS.
45.
EXPANSION
JOINTS IN CONCRETE (TYP). SEE DETAIL 31/C11.2. EXPANSION JOINTS SHALL BE SPACED
AT 24' MAX. ALIGN DRIVE-THRU CONTROL JOINTS WITH CURB CONTROL JOINTS.
46.
RELOCATED
CITY OF RENTON LUMINAIRE PER RENTON STD. PLAN 117.1.
47.
SEAL COAT
AND RESTRIPE ASPHALT WITHIN TEMPORARY CONSTRUCTION EASEMENT AS NECESSARY TO
RESTORE AREA TO EXISTING CONDITION OR BETTER.
48.
PROPOSED
DRIVE-THRU. SEE DETAIL 14/C11.1.
49.
PROPOSED
CURB CUT. SEE DETAIL 7/C11.4.
RECORD SITE PLAN
FOR
HI K-FIL=A RENTON
C C
SECTION 18, TWP. 23 N., RGE 5 EAST, W. M.
CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON
10' GAS EASEMENT /� a. `, 50 ACCESSIBLE PATH OF TRAVEL NOTE:
POWER EASEMENT KC REC. NO. 20130411001089 WALKWAYS ALONG ACCESSIBLE ROUTES OF TRAVEL SHALL BE CONTINUOUSLY
KC REC NO. 9410201209 ACCESSIBLE, A MINIMUM 48" IN WIDTH, HAVE A MAXIMUM 1.57. CROSS SLOPE,
AND SHALL HAVE RAMPS COMPLYING WITH ADA STANDARDS (SECTION 405) WHERE
° 3 NECESSARY TO CHANGE ELEVATION AT A LONGITUDINAL SLOPE EXCEEDING 5%
CONTRACTOR SHALL POTHOLE FOOTING OF 16� 42' (1:20). A CONTINUOUS 36" WIDE DETECTABLE WARNING STRIP MEETING ADA
ADJACENT EXISTING BUILDING TO ENSURE IT "E a
ISN'T ENCROACHING OVER THE PROPERTY LINE N7�•26 42 "� �' Lp STANDARDS (SECTION 406.8) SHALL BE PLACED WHERE A WALK CROSSES OR
`� \ SAWCUT AND REPLACE EXISTING ADJOINS A VEHICULAR WAY AND IS NOT SEPARATED BY A CURB, RAILING, OR
7 4 J ASPHALT
AS NE ESS RY FOR WATER
, OTHER ELEMENT MEETING ADA STANDARDS.
13 ° PQLA \INSTALLATION. MATCH EXISTING
a 3 GRADES AND TRENCH AND PATCH
ASPHALT PER CITY OF RENTON STD
•. o" .Og •0a 4 . %°. d° \\\ 46 SEA PLAN 110. OFF -SITE IMPROVEMENT NOTE:
° ° \olapoo THE CONTRACTOR SHALL COORDINATE WITH OWNER AND THE CITY OF RENTON FOR
41 15 \ 13 \ Qp�ER '�� PHASING OF OFF -SITE IMPROVEMENTS.
/ 17 a 0' `
,SLOPES & UTILITIES EASEMENT
° yea � 15 LP 20110620001119
° °
/
9 / e. °° °° � � 9SAWCUT A
13
0 4 CONCRETENAS REPLACEASTO EXISTING
s 30
18 �° �. ° ° s• INSTALL STORM AND MATCH
° 2� 3 °° a, \ EXISTING PAVEMENT SECTION AND
° ° ° 2 5 ° ' GRADES.
° ��! r : ° 7
° 2 4 °. °. a _ . °e °
SEWER EASEMENT ° ° C 4 ` \
REC NO. 525359515
8 a °° PARKING AND DRIVE AISLES INFORMATION
0 14 PARKING STALLS: 20
/ o O° ' ° ° \ 2 \ COMPACT PARKING STALLS: 13
4 40 ADA PARKING STALLS: 2
11 ° \
° o °
49\ TOTAL PARKING STALLS: 35
10' GAS EASEMENT / 0 12 \ ° `
44
KC REC NO. 20130411001089 41 °
° POWER EASEMENT `
4 15 5 4 0 ° 9 a KC REC. NO. 9410201209 0
° * 45 �� e
13 ss SLOPES & UTILITIES EASEMENT
° KC REC NO. 20110811001003
`�� 2 48 °� ° ��
4 O a� ° °° PROPOSED WATER
°. 1 8 ° ° 3 ° ° eEASEMENT \
°° 0 43
° °
. Qe,° .e. �� a
�°
e ° y a •..°. ' °' ° 10' GAS EASEMENT
a KC REC N0. 20130411001089 ,
BE REVISED) vv \
G° e
15' X 100' 15
SEWER EASEMENT 4.
® REC NO. 97081 10700 A ` °
\ / o
4 21
o °
9 � � � e. 42.03'
41 / ° 39 S19°57'04"E
\
19 � 04.48' a / 34
SANITARY SEWER EASEMENT
KC REC NO. 9708110701
Y
ae �
X� 39
16 . 13
0
s 36 - --- e----
30
° "
4 12 �Z`C MCP s• PROPOSED WATER
TEMPORARY CONSTRUCTION
EASEMENT e ,
EASEMENT 4 �6+ �h ' 6 ADA ACCESSIBLE PATH --'- e ® Know what s below.
8 ° p Call before you dig.
30 1 Dial 811
35 14 n s
ri
PROPOSED , WATER R-406344
-- � '
30 EASEMENT ', �� ACCESS EASEMENT
PER SHORT PLAT IN COMPLIANCE WITH CITY OF RENTON STANDARDS
ACCESS EASEMENT SAWCUT AND REPLACE EXISTING
PER SHORT PLAT ASPHALT AS NECESSARY TO INSTALL Q
WATER LATERAL AND MATCH `P`z
EXISTING PAVEMENT SECTION AND
GRADES. o 47671 �Q1_
i 1 s 01 S T
\ s/0NA L
5-7
50. RELOCATED STREET LIGHT.
Ba Uqh a use n
7
• •
Consulting Engineers, Inc•
SURVEYED:
RLH
DESIGNED:
SCALE:
In =201
L
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
C I T Y O F
o
o
RECORD SITE P LA N
I DATE:2 /19 /2019
FIELDBOOK:
JC
= - _-
RENTON
FOR
PAGE:
18215 72nd Avenue South
DRAWN:
CMS
ONE INCH
'
CHICK-FIL-A RENTON
DRAWING N0:
Kent, WA98032
AS -BUILT PLANS
MM
3/15/21
CRJ
CHECKED: AEM
AT FULL SCALE
Planning/Building/Public Works Dept.
375 RAINIER AVE S RENTON, WA 98055
C 7.0
425.251.6222 barghausen.com
NO.
REVISION
BY
DATE
APPR
APPROVED: CRJ
IF NOT ONE INCH
SCALE ACCORDINGLY
STORE NO.. 04249
SHEET: 1 OF: 24