Loading...
HomeMy WebLinkAboutR-406342J J W m Q 7E Q L0 (V CD N 7p 0 0 ry W Q i rn Do In 0 / Q0 rn 00 CD 0 O 00 n Lii M Q ® WATER STRUCTURE TABLE CD 1. RELOCATED FIRE HYDRANT. INSTALL PER CITY OF RENTON STANDARD DETAIL 310.1 AND 310.3 WITH 3LEVEL PAD. SEE DETAILS 1 /C9.2 AND 3/C9.2. CV 2. INSTALL: (1)-6" FDC PER CITY OF RENTON STANDARDS. SEE CITY OF RENTON STANDARD DETAIL DC 360.5. ~ 3. FIRE WATER CONNECTION TO WATER MAIN. INSTALL: (1) 6" TAPPING SLEEVE (FL X MJ) W/TB 4. 44 LF 6" CL52 D.I. 5. INSTALL: NEW DOUBLE DETECTOR CHECK VALVE ASSEMBLY WITH PIV FOR FIRE SERVICE PER CITY OF RENTON STANDARD 360.2. SEE DETAIL 2/C9.1. SIZE: 6" 6. 9 LF 6" CL52 D.I. 7. INSTALL: (1)-6" 90 DEGREE BEND (MJ X MJ) W/TB 8. 6 LF 6" CL 52 D.I. 9. INSTALL: (1)-6" 45° HORIZONTAL BEND MJ W/TB 10. 27 LF 6" CL52 D.I. 11. INSTALL: (1)-6" 45° HORIZONTAL BEND MJ W/TB 12. 33 LF 6" CL52 D.I. 13. INSTALL: (1)-6" 90° HORIZONTAL BEND MJ W/TB 14. 14 LF 6" CL52 D.I. 15. APPROXIMATE LOCATION OF FIRE LINE CONNECTION TO BUILDING. COORDINATE FINAL LOCATION WITH PLUMBING PLAN. INSTALL 6" DCDA PER CITY OF RENTON DETAIL 360.5. SEE DETAIL 5/C9.2. 16. NOT USED 17. WATER SERVICE CONNECTION TO EXISTING WATER MAIN BY CITY FORCES. 18. 34 LF 2" TYPE K COPPER TUBING DOMESTIC WATER SERVICE BY CITY FORCES. SEE DETAIL 3/C9.1. 19. NEW 1.5" WATER SERVICE AND METER (TO BE INSTALLED BY CITY FORCES) W/ REDUCED PRESSURE BACKFLOW ASSEMBLY PER CITY OF RENTON STANDARDS. SEE DETAIL 3/C9.1 FOR WATER CONNECTION. SEE DETAIL 2/C9.2 FOR RPBA. 20. 152 LF 2" TYPE K COPPER TUBING DOMESTIC WATER SERVICE. SEE DETAIL 3/C9.1. 21. APPROXIMATE LOCATION OF WATER SERVICE CONNECTION TO BUILDING. COORDINATE FINAL LOCATION WITH PLUMBING PLAN 22. 237 LF NEW 1.5" TYPE K COPPER TUBING DOMESTIC WATER SERVICE. SEE DETAIL 3/C9.1. 23. APPROXIMATE LOCATION OF WATER SERVICE CONNECTION TO TRASH ENCLOSURE. COORDINATE WITH TRASH ENCLOSURE PLAN FOR EXACT LOCATION. INCLUDE RPBA PER DETAIL 2/C9.2 24. PLACE NEW 1' WATER METER IN EXISTING METER BOX BY CITY FORCES. INSTALL 1' DCVA PER CITY OF RENTON STANDARD PLAN 340.8. SEE DETAIL 4/C9.2. 25. 16 LF 6" CL52 D.I. 26. INSTALL: (1)-6" 45° HORIZONTAL BEND MJ W/TB 27. 59 LF 6" CL52 D.I. 28.INSTALL: (1)-6" 45° HORIZONTAL BEND MJ W/TB 29. 22 LF 6" CL52 D.I. 30. INSTALL: (1)-6" 45° HORIZONTAL BEND MJ W/TB 31. 22 LF 6" CL52 D.I. 32. INSTALL: (1)-6" 90° HORIZONTAL BEND MJ W/TB 33. 3 LF 6" CL52 D.I. 34. INSTALL: (1)-6" 90° HORIZONTAL BEND MJ W/TB ACCESS EASEMENT PER SHORT PLAT 35. 3 LF 6" CL52 D.I. 36. WATER CONNECTION TO EXISTING WATER MAIN FOR SERVICE TO 364 RENTON CENTER WAY SW. 37. 34 LF 1.5" TYPE K COPPER TUBING DOMESTIC WATER SERVICE. SEE DETAIL 3/C9.1. 38. NEW 1.5" WATER SERVICE AND METER (TO BE INSTALLED BY CITY FORCES) W/ REDUCED PRESSURE BACKFLOW ASSEMBLY PER CITY OF RENTON STANDARDS FOR SERVICE TO 364 RENTON CENTER WAY SW. SEE DETAIL 3/C9.1 FOR WATER CONNECTION. SEE DETAIL 2/C9.2 FOR RPBA. 39. CONTRACTOR TO FIELD LOCATE EXISTING TIE IN POINT FOR DOMESTIC SERVICE PRIOR TO CONSTRUCTION. CONTRACTOR TO CONFIRM ANY NOTIFICATION REQUIREMENTS WITH OWNER PRIOR TO CONSTRUCTION. 40. CONTRACTOR TO INSTALL 1.5" TYPE K COPPER TUBING FOR SERVICE TO 364 RENTON CENTER WAY SW. CONTRACTOR TO CONFIRM LENGTH REQUIRED PRIOR TO CONSTRUCTION 41. PROTECT EXISTING HYDRANT TO REMAIN DURING CONSTRUCTION. 42. PROPOSED WATER EASEMENT. 43. 9 LF OF 6" CL52 D.I. 44. 6 LF OF 6" CL52 D.I. 45.INSTALL: (1)-6" 45° HORIZONTAL BEND MJ W/TB RECORD WATER PLAN FOR CH.1CK=FIL=A RENTON SECTION 18, TWP. 23 N., RGE 5 EAST, W. M. CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON POWER EASEMENT KC REC NO. 9410201209 �I 0 0 I M SEWER EASEMENT REC NO. 5253595 I /I �I 10' GAS EASEMENT KC REC NO. 20130411001089 I ° G °G 15' X 100' SEWER EASEMENT REC NO. 9708110700 364 RENTON CENTER ® WAY SW SANITARY SEWER EASEMENT 1 KC REC NO. 97081 10701 o X X X - y G --- - ss -SS- SS - SS ASS -SS -S�ss-ss ssi N I I SO � I � N I I I I ' I N N I I Barghausen Consulting Engineers, Inc. 18215 72nd Avenue South Kent, WA 98032 425.251.6222 barghausen.com I I � z I S SS O v N O I I O - U, " 13 N 12 Ln 4 a; N 11 6 0 S c 10' GAS EASEMENT ❑ KC REC. NO. 20130411001089 4��00720-0.1.,9 A I L I �1 APN 000720-0215 @Q0 °D N FA If vI f:f `I 0 0 FIRE LINE NOTE: 1. FIRE LINE AND BACKFLOW PREVENTION DEVICE SIZE SHALL BE VERIFIED AND APPROVED BY FIRE OR MECHANICAL ENGINEER PRIOR TO CONSTRUCTION. COORDINATE FINAL CONNECTION POINTS INTO BUILDING WITH PLUMBING DESIGNER AND FIRE OR MECHANICAL ENGINEER. SCOPE OF WATER WORK NOTE: 1. CONTRACTOR TO VERIFY SCOPE OF WORK FOR WATER CONNECTION WITH THE CITY OF RENTON PRIOR TO CONSTRUCTION. 2. SEE C9.1 FOR CITY OF RENTON WATER UTILITY AND WATER PLAN GENERAL NOTES. 3. WATER CONNECTIONS IN FRED MEYER DRIVEWAY MUST BE COMPLETED DURING TIMES WHERE FRED MEYER IS CLOSED. UTILITY CROSSING NOTES: OCONTRACTOR IS TO PROVIDE A MINIMUM OF 1.5' VERTICAL SEPARATION BETWEEN SANITARY SEWER AND WATER, A MINIMUM OF 0.5' VERTICAL SEPARATION FOR DRY UTILITIES. CONTRACTOR SHALL NOTIFY BARGHAUSEN SLOPES & UTILITIES EASEMENT CONSULTING ENGINEERS, INC. OF ANY CONFLICTS. PER 20110620001119 � II POWER EASEMENT KC REC. NO. 9410201209 [` " I 4 I I � I Z M PWG) P D I C m L & UTILITIES EASEMENT C NO. 20110811001003 4 I � II � I I y II f I 1h 2 II m I � II f I II I I a a: 41 °. ; 10' GAS EASEMENT KC REC NO. 20130411001089 (TO BE RELINQUISHED) IV O �/00 38 45 0 1 1 1 1 44 0 _ - w _-- -- -_ 42 4 18 -�E DRIVE 4 19 PRN A 1 , 1 1 ,3 17 -w-w- 3 IN IN w w w _-__ --- �c �GcV e0 n 11 WW ,� 4 4 _ ° v ° rG `� R�S EA I,,, w - W =14 IN IN _-- - ° EXISTING 8" D.I. Jy SFii w w - w _--- WATER MAIN _ -- ACCESS EASEMENT z °' PER SHORT PLAT °P 47671 � F6' 1 S T IONA L SURVEYEi SCA" VERTIC/� DESIGNED c 9 2� 0 ')RIZON AL JNAD 1983/1991 O CI T Y OF RENTON DRAWN: CMS ONE INCH • AS -BUILT PLANS MM 3/15/21 CRJ CHECKED: AEM AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH REVISION )ATE APPR APPROVI_ CRJ SCALE ACCORDINGLY UTILITY POTHOLING: SEE SHEET C10.0 FOR POTHOLING REQUIREMENTS 0 Know what's below. 0 Call before you dig. 1 Dial 811 s R-406347 IN COMPLIANCE WITH CITY OF RENTON STANDARDS RECORD WATER PLAN 0 FOR CHICK-FIL-A RENTON ® 375 RAINIER AVE S RENTON, WA 98055 6.408-_ STORE NO.:04249 12/19/2019 FIELDBOOK: PAGE: DRAWING NO: C9.0 bI,ttI:15 U�:24