Loading...
HomeMy WebLinkAboutW-406304M Q0 O O d' 0 w M O N M O N L'J m Q m 0 N N CD N i rn 00 QD U) 0 i 00 0 0 CD 00 n POWER EASEMENT KC REC NO. 9410201209 TO BE RELINQUISHED PROPOSED SANITARY — SEWER, SEE SHEET C8.0 10' GAS EASEMENT KC REC NO. 20130411001089 PROPOSED STORM DRAIN, SEE SHEET C5.0 15' X 100' SEWER EASEMENT ® REC NO. 9708110700 SANITARY SEWER EASEMENT - KC REC NO. 9708110701,, ^PERJ SHORT PLAT �S SO — SO — i RECORD COMPOSITE UTILITY PLAN FOR UTILITY PROTECTION NOTE: UTILITY LOCATE DATA INDICATES THE EXISTENCE AN CHICK=FIL=A RENTON EXISTING GAS SERVICE LOCATED UNDER THE SIDEWALK AND CURB RETURN OF RAINIER AVENUE. THE SECTION 18, TWP. 23 N., RGE 5 EAST, W. M. CONTRACTOR SHALL ORDER INDEPENDENT UTILITY CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON LOCATES AND TAKE ANY OTHER NECESSARY ACTIONS To CONFIRM THE HORIZONTAL AND VERTICAL LOCATIONS. EXISTING GAS SERVICE TO BE PROTECTED. 10' GAS EASEMENT aso ADJUST VALVE COVER TO FINISHED GRADE 's� a KC REC. N0. 20130411001089 � \ \hk ADJUST FRAMES LID TO FINISHED GRADE AND REPLACE WITH TRAFFIC RATED LID 26. 42„E 6l 42 I o0 SLOPES & UTILITIES EASEMENT\ PER 20110620001119 \\ \� POWER EASEMENT KC REC. NO. 9410201209 m 2 � \\ \ + 4 G O 4 0 �m \SLOPES & UTILITIES EASEMENT Q 2 KC REC NO. 20110811001003 2 \\ A \ ✓C% 6 7 10' GAS EASEMENT KC REC NO. 2013041 1001089 i (TO BE REVISED) c+ o S \ c G c,/ \ 9. T ACCESS EASEMENT PER SHORT PLAT f I 2 a. V 10' PROPOSED GAS EASEMENT ,__S10'53'15-W ,r. 42.03' UTILITY NOTES: O CONTRACTOR IS TO PROVIDE A MINIMUM OF 1.5' VERTICAL SEPARATION BETWEEN SANITARY SEWER AND WATER, A MINIMUM OF 0.5' VERTICAL SEPARATION FOR DRY UTILITIES. CONTRACTOR SHALL NOTIFY BARGHAUSEN CONSULTING ENGINEERS, INC. OF ANY CONFLICTS. O THE CIRCLED LOCATIONS ARE REQUIRED TO BE POTHOLED TO CONFIRM WHETHER OR NOT UTILITY CONFLICTS NEED TO BE RESOLVED. POTHOLING SHOULD OCCUR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY BARGHAUSEN CONSULTING ENGINEERS, INC. OF ANY CONFLICTS. ® DRY UTILITIES CONSTRUCTION NOTES: 1. APPROXIMATE LOCATION OF GAS METER AND SERVICE. COORDINATE METER LOCATION AND SERVICE WITH PURVEYOR AND MEP PLANS. 2. APPROXIMATE CONNECTION FOR GAS SERVICE. CONFIRM SIZE, LOCATION, AND CONTRACTOR SCOPE OF WORK WITH PURVEYOR PRIOR TO CONSTRUCTION. 3. APPROXIMATE LOCATION OF PROPOSED TRANSFORMER. COORDINATE CONDUIT SIZE, METER LOCATION AND CONTRACTOR SCOPE OF WORK WITH PURVEYOR AND MEP PLANS PRIOR TO CONSTRUCTION. 4. APPROXIMATE LOCATION OF PRIMARY POWER SERVICE FROM EXISTING VAULT TO PROPOSED TRANSFORMER. COORDINATE CONDUIT SIZE, AND CONTRACTOR SCOPE OF WORK WITH PURVEYOR AND MEP PLANS PRIOR TO CONSTRUCTION. CONTRACTOR TO VERIFY THAT NO CONFLICT EXISTS BETWEEN POWER SERVICE AND WALL FOOTINGS PRIOR TO CONSTRUCTION. 5. APPROXIMATE LOCATION OF TELEPHONE/ISP CONDUIT CONNECTION TO BUILDING. COORDINATE LOCATION, MATERIAL AND CONTRACTOR SCOPE OF WORK WITH PURVEYOR AND ELECTRICAL PLANS PRIOR TO CONSTRUCTION. 6. TWO 2" TELEPHONE SERVICE ENTRANCE CONDUIT(S). EXTEND WITH PULL STRING FROM TELEPHONE SERVICE J-BOX TO UTILITY SOURCE. REFER TO SHEET ES1.1 FOR ADDITIONAL INFORMATION. 7. ONE 3" ISP SERVICE CONDUIT. EXTEND WITH PULL STRING FROM THE J-BOX TO THE SUPPLIER'S SOURCE. REFER TO SHEET ES1.1 FOR ADDITIONAL INFORMATION. 8. APPROXIMATE LOCATION OF POWER SERVICE TO TRASH ENCLOSURE. COORDINATE CONDUIT SIZE, METER LOCATION AND CONTRACTOR SCOPE OF WORK WITH MEP PLANS PRIOR TO CONSTRUCTION. 9. APPROXIMATE CANOPY CONNECTION FOR GAS/POWER SERVICE. CONFIRM SIZE, LOCATION, AND CONTRACTOR SCOPE OF WORK WITH PURVEYOR AND CANOPY PLANS PRIOR TO CONSTRUCTION. 10. APPROXIMATE LOCATION OF POWER SERVICE BETWEEN PROPOSED TRANSFORMER AND EXISTING VAULT. EXISTING VAULT TO BE REPLACED WITH HAND HOLE FOR POWER CONNECTION TO 351 RAINIER AVE. COORDINATE ANY WORK REQUIREMENTS WITH ADJACENT PROPERTY OWNER PRIOR TO CONSTRUCTION. COORDINATE CONDUIT SIZE, LOCATION AND CONTRACTOR SCOPE OF WORK WITH PURVEYOR AND MEP PLANS PRIOR TO CONSTRUCTION. 11. APPROXIMATE LOCATION OF POWER SERVICE BETWEEN PROPOSED TRANSFORMER AND BUILDING. COORDINATE CONDUIT SIZE, METER LOCATION AND CONTRACTOR SCOPE OF WORK WITH PURVEYOR AND MEP PLANS PRIOR TO CONSTRUCTION. 12. APPROXIMATE LOCATION OF GAS LINE RELOCATION. PSE RELOCATED LINE RECENTLY. SEE SHEET C3.0 FOR ADDITIONAL NOTES ON GASLINE AND POTENTIAL CONFLICTS. COORDINATE SIZE, LOCATION AND CONTRACTOR SCOPE OF WORK WITH PURVEYOR PRIOR TO CONSTRUCTION. 13. PROVIDE POWER TO PROPOSED MONUMENT SIGN. COORDINATE CONDUIT SIZE AND CONTRACTOR SCOPE OF WORK WITH MEP PLANS PRIOR TO CONSTRUCTION. 14. APPROXIMATE LOCATION OF GAS LINE RELOCATION. COORDINATE SIZE, LOCATION AND CONTRACTOR SCOPE OF WORK WITH PURVEYOR PRIOR TO CONSTRUCTION, 15. CONTRACTOR TO PROVIDE ELECTRICAL SERVICE TO RELOCATED LUMINAIRE FROM EXISTING ELECTRICAL BOX. R CROSSING TABLE 0 Know what's below. p Call before you dig. 1 Dial 811 S-406303 ' _W-406304 R-406313 IN COMPLIANCE WITH CITY OF RENTON STANDARDS SIN s\ % / i ` / �/i • 1% . % �S��NA��N�, ,5i��h� 2 J Barghausen Consulting Engineers, Inc. 18215 72nd Avenue South Kent, WA98032 425.251.6222 barghausen.com RLH 1�=20' VE HORIZON CITY OF 'R R E N T O N Planning/Building/Public WorKs Dept. O o RECORD COMPOSITE UTILITY PLAN 0 FOR CHICK-FIL-A RENTON 375 RAINIER AVE S RENTON, WA 98055 STORE NO.: 04249 12/19/2019 DLSiGNL_ JC F,ELDBOOK: PAGE DRAWING Nt DRAWN: CMS AS -BUILT PLANS MM 3/15/21 CRJ AEM I ONE NCH I AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY C 10.0 REVISION CRJ SHEET: 18OF: 24