Loading...
HomeMy WebLinkAboutR-4097134ONFIGURAT1O N ON SLOPING GROUND ❑DWNSPDUT WITH CLEANOUT FILTER, SEE DETAIL r CLEANOUT PER $TD. PLAN 220-00 r 11Y MIN. LEVEL TRENCH WITH PERFORATED PPE - SEE NOTE 1 I 5 r MIN r I MIN d a I CLEANO PER I STD. PLAN 326.00 TO STORM DRAIN SYSTEM e i — — — — i I FOOTING DRAIN BYPASS ? r I MIN. MIH. I CFJLNOVT PER STD. PLAN 2213L.00 I ra STORM DRAw SYSTEM I DOWNSPOUTWITHCLaANOUT FILTER. SEE DETAIL MIN- LEVEL TRENCH ITH I` I i■ PE PERFORATED PIPE, SEE NOTE 1 , NO — — — — — — — — — — — — — — — — — — — — — — — — — CONFIGURATION ON FLAT GROUND COMPACTED TOPSOIL OR OTHER CLEAN FILL NON -WOVEN GEOTEVILE FOR SEPARATIou ON TOP AND SIDES OP TRENCH PER WSDOT SPECIFICATIONS SECTION 8-33.E{1 } TABLE 3 *114 T -A P [Q [ 1&' MIN. UNDISTURBED NATIVE -^.AIL PLAN VIEW OF PARCEL r` 6' MIN. PVC i PERFORATED PIPE PER ASTM D1 TAS souo-sJ LEAVES ,1 � li FFLTER SCREEN )UROCK WASHED ORN RO DRAJCK 2-5i TO GROUND 24- MIN. _iJ_ TYPICAL DOWNSPOUT MIN, VABOVE SEASONAL HIGH GROUNDWATER TABLE NOTES: 1, TRENCH LENGTH TO SE 19 FEET IN LENGTH FOR EVERY 5,900 SF OF CONTRIBUTING WPERVIDUS SURFACE, OR 35-M SF OF NON-NATVE PERVIOUS SURFACE. OR PORTION THEREOF. GENERAL MOTES: 1. INFILTRATION TRENCHES LIMITED TO ROOF RUNOFF FROM SFNGLE-FAMILY OR DUPLEX HOMES OR TO CONTROL BASEMENT FLWDI NG- CONSULT WA DEPARTMENT OF ECOLOGY REGULATIONS FOR UNDERGROUND INJECTION CONTROL PROGRAM LULCI FOR OTHER TYPES OF RUNOFF MANAGEMENT, 2. IMPERVIOUS AREAS LARGER THAN MOW SF AND NON-NATIVE PERVIOUS AREAS LARGER THAN 35.000 SF MAY REQUIRE LARGER PIPE AND SHOULD BE DESIGNED BY A CIVIL ENGINEER. 3 THE PERFORATED PIPE MAY NOT HE PLACED IN A ORFw& AREA BUFFER OR ON SLOPES STEEPER THAN 25%, 4. SEE C04STRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHFRYI5F N01-0, PRAWING I$ MOl' TV SCALE INTSI STD. PLAN - 263.40 � w PUBLIC WORKS PERFORATED STAB -OUT APPR ED U" DEPARTMENT CONNECTION GAZ 9/28/2018 1 DATF co co c a� ry 00 00 co 0 0 CD z J � SMOOTH COUPLING BAND FOR SMOOTH PIPE 3- I ROAD DRAINAGE NOTES AND DETAILS OF DALPAY SHORT PLAT A PORTION OF THE N.E. 1/4 OF THE S.E. 1/4 OF SECTION 4, TOWNSHIP 23 N., RANGE 5 E., W.M. CITY OF RENTON, KING COUNTY, WASHINGTON COUPLING SAND r' WELD T WELD PLATE (SEE DETAIL} i MATERIAL TO BE ASTM A35 .6' PIPE GALVANIZED AFTER FABRICATION STAILEH EACH PER ASTM A153 I' LAT I -EN 51DE OF CULVERT TO POINT ANCHOR ASSEMBLY CORRUGATED METAL PIPE R1" UYP.1 R1"[TYP,) MATERIAL TO BE ASTM A 36 V4" PLATE GALVANIZED AFTER FABRICATION PER ASTM Al93 •lals ul 6e 6 5w .R hn1- 3:4' diem. 71913E x 34" 14 11A" _ 6-- - ,L, 1 7r 71s- 7'CUUPLINGBANO ` 4 1r2- i 4 1f2- 12.OR 24" COUPLING BAND 12" PLATE DETAIL GENERAL NOTES: 1. THE SMOOTH COUPLING BANG SHALL BE USED IN COMBENATK)N W FTH CONCRETE PIPE. 2. CONCRETE PIPE WITHOUT BELL AND SPIGOT SHALL NOT BE INSTALLED ON GRADES IN EXCESS OF 20%. 3. THE FIRST ANCHOR SHALL BE INSTALLED ON THE FIRST SECTION OF THE LOWER END OF THE PIPE AND REMAINING ANCHORS EVENLYBPArN)THROUGHOUT THE. INSTALLATION. A. IF THE PIPE BEING INSTALLED HAS A MANHOLE OR CATCH BASIN ON THE LOWER END OF THE PIPE, THE FIRST PIPE ANCHOR MAY BE ELIMINATED. S- WHEN CMP IS USED, THE ANCHORS MAY HE ATTACHED TO THE COUPLING BANDS USED TO JOIN THE PIPE AS LONG AS THE SPECIFIED SPACING IS NOT EXCEEDED. 9- ALL PPE ANCHORS SHALL BE SECURELY INSTALLED BEFORE BAC91FILLING AROUND THE PiP_: PIPE STAKE MP-) TABLE 4.2.1.A3 MAXIMUM PIPE SLOPES AND VELOCITIES PIPE SLOPE ABOVE WHICH PIPE M#IJL SLOPE MAX. VELOcFTV AT PIPE MATERIAL ANCHORS REQUIRED ALLOWED FULL FLOW AND MJN, ATtCHOR SPACING CMP. SPIRAL RIB. PVU 20% (1 ANCHOR PER %� 3ti PPS 100 LF OF PIPE) CONCRETE, CPE, OR PP' 10'W {1 ANC1tOGi PER 28%' �,n FPS 54 LF OF PIPE) DUCTILE IRON' 20% (1 ANCHOR PER NONE NONE PIPE SECTION} 20% (1 RNCHOR PER SOLID WAIL HDPE� 104 LF OF PIPE' HONE NONE CROSS -SLOPE INSTALLATIONS ONLY, NOTES: `THESE MATERIALS ARE NOT ALLOWED IN LANDSLIDE HAZARD AREAS. ' BUTT -FUSED OR FLANGED PIPE JOINTS ARE REOUERED- ABOVE GROUND INSTALLATION IS RECOMMENDED ON SLOPES GREATER THAN 40% A MAXIMUM SLOPE OF 200% IS ALLOWED FOR THESE PIPE MATERIALS WITH NO JOINTS LONE SECTION), WITH STRUCTURES AT EACH END, ANO WITH PROPER GROUTING UNLESS OTHERWISE MATED, DRAWING IS NOT TU SCALE (NISI STn. PLAN - 221.20 PUBLIC WORKS CORRUGATED METAL PIPE COUPLINGURI P°R DEPARTMENT AND GENERAL PIPE ANCHOR ASSEMBLY GAZ 9/28/2018 nuc uer.r...... ..rux DATE 2 PER COR COMMENTS DATED 6/8/20 1 PER COR COMMENTS DATED 10/31/19 NO. REVISION ENERGY DISSAPATOR PLAN ENERGY DISSAPATOR SECTION A -A EX. GROUND \/ SURVEYED: TSL DESIGNED: DSC DC 6/10/20 DID DRAWN. DSC DC 12/2/19 DID CHECKED: DID BY DATE AP P R APPROVED: DD iv 8" HDPE PIPE PLACE FILTER FABRIC BETWEEN GABIONS AND SOIL BEDDING ENERGY DISSAPATOR SECTION B-B SCALE: VERTICAL: NAVD 1988 N/A HORIZONTAL: HAD 1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY CITY OF RENTON 0'R Planning/Building/Public Works Dept. OWj � r42009 ��10 FSTO, \�� /ONA L LNG 9-21-20 ci E 0 � � 3 4-1 al .� O ul) C � � � W N O M V: i 0000N �d1N C Q .m j 0) /c�v W O V 0() r (, Y N Nt R-409713 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING I Nathan Janders 11/12/2020 ='R C� a 00 00 SURFACE WATER UTILITY jfarah 11/13/2020 p DATE: ROAD DRAINAGE NOTES AND DETAILS 6/18/19 V) m DALPAY SHORT PLAT FIELDBOOK: DALPAY PROPERTIES LLC. PAGE: f DRAWING NO: 4033 N.E. SUNSET BOULEVARD I -a �-! RENTON, WA 98059 SHEETCIIB R 18 A oU0"