HomeMy WebLinkAboutR-409731I I I I x 0 0 0 Of 0 z Ld 4i 0 V cn rn 0 CV N 0 cv rn E a� a 0 3 0 LIJ I 00 00 i CS 00 co 0 CD CD r- W Z r` Cn 0 1 O 1 0 L.L i N CITY OF RENTON EROSION AND SEDIMENT CONTROL NOTES 1. CLEARING LIMITS: A. PRIOR TO ANY SITE CLEARING OR GRADING, AREAS TO REMAIN UNDISTURBED DURING PROJECT CONSTRUCTION SHALL BE DELINEATED. AT A MINIMUM, CLEARING LIMIT DELINEATION FLAGGING SHALL BE PROVIDED AT THE EDGES OF ALL VE AREA BUFFERS. 2. KEEP THE GROUND COVERED: A. MINIMIZE THE AMOUNT OF EXISTING VEGETATION THAT YOU MUST DISTURB FOR CONSTRUCTION. KEEP OFF SENSITIVE AREAS AND THEIR BUFFERS. B. ALL DISTURBED AREAS SHALL BE COVERED AND/OR MULCHED WITHIN 12 HOURS, IF THEY ARE TO REMAIN UNWORKED FOR MORE THAN 7 DAYS FROM MAY 1ST TO SEPTEMBER 30TH. DURING THE MONTHS OF OCTOBER 1ST THROUGH APRIL 30TH, DISTURBED AREAS MUST BE COVERED OR MULCHED IF LEFT UNWORKED WITHIN 2 DAYS C. ACCEPTED MULCH MATERIAL INCLUDES STRAW, WOOD FIBER AND CELLULOSE. D. AREAS NOT BEING WORKED FOR 30 DAYS OR MORE SHALL BE VEGETATED, UNLESS THE CITY DETERMINES THAT WINTER WEATHER MAKES VEGETATION ESTABLISHMENT INFEASIBLE. IF THIS IS THE CASE, IT MUST STILL BE MORE PERMANENTLY STABILIZED, USING METHODS SUCH AS BONDED FIBER MATRIX OR OTHER MORE STABLE BMP'S. E. SLOPES AND STOCKPILES 3H:1V OR STEEPER AND MORE THAN 10 FEET OF VERTICAL RELIEF SHALL BE COVERED IF THEY ARE UNWORKED FOR MORE THAN 12 HOURS. F. ALL AREAS NOT BEING WORKED PRIOR TO OCTOBER 1, AND ARE BEING SEEDED, SHALL BE SEEDED BY SEPTEMBER 23. MULCHING IS REQUIRED TO PROTECT ALL SEEDED AREAS UNTIL AN ADEQUATE GROWTH IS ESTABLISHED. G. AREAS THAT ARE BEING HYDRO SEEDED SHALL HAVE A TACKIFIER MIXED INTO THE HYDRO SEED TO HELP STABILIZE MIXTURE ONTO THE SOIL. H. ENOUGH COVER MATERIAL TO SUFFICIENTLY PROTECT ALL DISTURBED AREAS SHALL BE STOCKPILED ON THE SITE AT THE BEGINNING OF THE WET SEASON. 3. DUST CONTROL: A. DUST IS TO BE CONTROLLED ON THE CONSTRUCTION SITE. B. WATER TRUCK WILL BE USED TO CONTROL DUST ON DIRT/GRADED AREAS ONLY. C. NO SITE RUN OFF IS TO BE GENERATED BY OVER USE OF WATERING. D. CONTROLLING DUST ON PAVED ROADWAYS WILL BE DONE BY THE USE OF A SWEEPER WITH WATER -JET SPRAYERS. NO RUN OFF FROM SPRAYERS SHALL REACH THE CATCH BASINS. 4. PERIMETER PROTECTION: A. PERIMETER PROTECTION TO FILTER SEDIMENT FOR SHEETWASH SHALL BE LOCATED DOWNSLOPE OF ALL DISTURBED AREAS AND PROPERLY INSTALLED PRIOR TO UPSLOPE GRADING. B. 50 LINEAR FEET OF SILT FENCE PER ACRE AND THE NECESSARY STAKES TO HOLD THE FENCE IN PLACE SHALL BE STORED ON SITE. 5. TRAFFIC AREA STABILIZATION: A. UNSURFACED DRIVEWAY ENTRANCES, ACCESS ROADS AND PARKING AREAS USED BY CONSTRUCTION TRAFFIC WILL BE STABILIZED TO MINIMIZE EROSION AND PREVENT TRACKING MUD. B. STABILIZED CONSTRUCTION ENTRANCES WILL BE INSTALLED AS THE FIRST STEP OF CLEARING AND GRADING. C. CONSTRUCTION ENTRANCES WILL BE SET UP SO THAT ALL TRAFFIC LEAVING A JOB SITE IS REQUIRED TO TRAVEL THE ENTIRE LENGTH OF ENTRANCE. D. ROADS AND PARKING AREAS WILL BE STABILIZED IMMEDIATELY AFTER THE INITIAL GRADING. E. CONSTRUCTION ENTRANCES WILL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE. F. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT WILL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON -SITE. G. IF NON-VACTOR TYPE SWEEPERS ARE USED, THE DEPOSITION OF THESE SWEEPERS MUST BE REMOVED FROM SIDEWALKS AND GUTTERS. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON -SITE. H. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING STREETS. TEMPORARY EROSION CONTROL SEED MIX EROSION AND SEDIMENT CONTROL NOTES ASBUILT TESC NOTES AND DETAILS 6. SEDIMENT RETENTION: OF A. SEDIMENT RETENTION IS REQUIRED UNLESS NO OFF -SITE DISCHARGE IS ANTICIPATED FOR THE SPECIFIED DESIGN FLOW. DALPAYSHORT PLAT B. SEDIMENT RETENTION FACILITIES WILL BE INSTALLED BEFORE GRADING. C ADDITIONAL NPONDS/TRAPS/SYSTEMS IOTO ACCOMMODATE N FACILITIES NEED TO BE RESTORAGE VED OCAPACITY DNEED TO BE A PORTION OF THE N.E. 1/4 OF THE S.E. 1/4 OF SECTION 4, TOWNSHIP INSTALLED ON SITE. THIS WILL BE DONE PRIOR TO REMOVAL OF EXISTING FACILITY. 7. SURFACE WATER CONTROL: 23 N., RANGE 5 E., W.M. CITY OF RENTON, KING COUNTY, WASHINGTON A. SURFACE WATER CONTROLS ARE REQUIRED UNLESS NO OFF -SITE DISCHARGE IS ANTICIPATED FOR THE SPECIFIED DESIGN FLOW. 8. SENSITIVE AREA RESTRICTIONS: A. PHASING AND MORE CONSERVATIVE BEST MANAGEMENT PRACTICES (BMP'S) MUST BE EVALUATED FOR CONSTRUCTION ACTIVITIES NEAR SURFACE WATERS.. 9. MAINTENANCE REQUIREMENTS: A. LARGE PROJECTS WITHIN SENSITIVE AREAS MAY BE REQUIRED BY THE CITY TO HAVE A DESIGNATED ESC SUPERVISOR WHO WILL BE RESPONSIBLE FOR ESC REVIEW, B. MAINTENANCE AND COMPLIANCE. C. ESC WILL BE INSPECTED A MINIMUM OF ONCE A WEEK DURING THE WET SEASON AND WITHIN 24 HOURS OF SIGNIFICANT STORMS (.5 INCHES/24 HOUR, OR WHERE RUN-OFF IS GENERATED). D. THE ESC SUPERVISOR MUST BE AVAILABLE, 24 HOURS, FOR RAPID RESPONSE TO ESC PROBLEMS AND EMERGENCIES. E. A 24-HOUR PHONE NUMBER FOR THE ESC SUPERVISOR WILL BE POSTED IN A CLEARLY VISIBLE LOCATION ON THE PROJECT SITE. 10. FINAL STABILIZATION: PRIOR TO FINAL CONSTRUCTION APPROVAL, THE FOLLOWING CONDITIONS MUST BE MET: A. ALL DISTURBED AREAS OF THE SITE WILL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED; B. STRUCTURAL MEASURES SUCH AS SILT FENCE, SLOPE DRAINS, ETC. WILL BE REMOVED FROM SITE; C. ALL PERMANENT SURFACE WATER FACILITIES INCLUDING CATCH BASINS, PIPES, ETC. WILL BE CLEANED; D. ANY OFF -SITE CATCH BASINS THAT REQUIRED PROTECTION WILL ALSO BE CLEANED; AND E. IF ONLY THE INFRASTRUCTURE OF THE SITE HAS BEEN DEVELOPED SUCH AS SHORT PLATS AND SUBDIVISIONS, WITH BUILDING CONSTRUCTION TO OCCUR UNDER A DIFFERENT F. PERMIT, THEN THE SENSITIVE AREA BUFFERS, TRACTS, AND SETBACKS WILL BE CLEARLY MARKED. CITY OF RENTON, DEVELOPMENT SERVICES STAFF IS AVAILABLE TO ANSWER ANY QUESTIONS YOU MAY HAVE ABOUT EROSION AND SEDIMENT CONTROL AND WET SEASON STABILIZATION MEASURES FOR PERMITTED ACTIVITIES IN THE CITY OF RENTON. PLEASE CALL 425-430-7300. MATERIAL % WEIGHT % PURITY % GERMINATION CHEWINGS OR RED FESCUE 40 98 90 FESTUCA RUBRA VAR. COMMUTATA OR FESTUCA RUBRA ANNUAL OR PERENNIAL RYE 40 98 90 LOLIUM MULTIFLORUM OR LOLIUM PERENNE REDTOP OR COLONIAL BENTGRASS AGROSTIS ALBA OR AGROSTIS TENUIS 10 92 85 WHITE DUTCH CLOVER TRIFOLIUM REPENS 10 98 90 BEST MANAGEMENT PRACTICES (BMP) ALTERNATIVES MULCH MATERIAL OUAUTY STANDARDS APPUCAl1 _N7 /1000 SF APPLICATION /ACRE DEPTH OF APPLICATION TENSAR GS-1 SAFETY FENCE OR EQUAL (BRIGHT ORANGE PLASTIC MESH) 10' 14 (A GAI VAN17Fn WIRE I I J Vll. VlIL VlIIVI, II STEEL FENCE POST 6' HIGH MIN u NOTE: 1: CLIP FENCE TO GALVANIZED WIRE @ 5 FOOT ON -CENTER SPACING 2. WIRE FENCE TO STEEL FENCE POST TEMPORARY N.G.P.E. FENCE DETAIL NOT TO SCALE REMARKS GRAVEL, SLAG, OR WASHED, 3/4 -1-1/2 9 CU YDS 3 INCHES FOR SHORT SLOPES AND AROUND WOODY PLANTS & ORNAMENTALS CRUSHED STONE SIZE USE WHERE SUBJECT TO FOOT TRAFIC. APPDX. 2000 LBS/CU YD. AIR DRIED, FREE FROM 75-100LBS OR 1-1/2 TO 2-1/2 MINIMUM OF 2 IN USE WHERE THE MULCHING EFFECT IS TO BE MAINTAINED FOR LESS HAY OR STRAW UNWANTED SEEDS & 2-3 BALES TONS OR 90-120 DEPTH, GREATER ON THAN 3 MONTHS. ANCHOR BY CRIMPING, COVERING WITH NETTING COARSE MATERIAL BALES STEEP AREAS OR NEAR SPRAYING WITH TACKIFIER AND/OR KEPT MOIST. PROTECTED AREAS) PLASTIC SHEETING MINIMUM 6-MIL THICKNESS JUTE MAT, WOVEN N/A STRAW BLANKET SYNTHETIC FIBER BLANKET WOOD FIBER DYED GREEN SHOULD CELLULOSE (PARTIALLY NOT CONTAIN GROWTH DIGESTED WOOD INHIBITING FACTORS FIBERS) WOOD FIBER APPLIED WITH HYDROSEEDING OR ALONE BARK CHIPS WOOD CHIPS TREAT WITH 12LBS (HOG FUEL) NITOGEN FERTILIZER/TON HYDROSEED USE MIX RECOMMENDED ABOVE PER CITY OF RENTON STANDARD DETAIL 213.30 ON SHEET C5 N/A USE ON STEEP SLOPES GREATER THAN 2:1 IN ADDITION TO HYDROSEED OR WOOD FIBER WITH TACKIFIER. 25-30 LBS. 1000-1500LBS IF USED ON CRITICAL AREAS, OR STEEP SLOPES, DOUBLE THE NORMAL APPLICATION RATE. APPLY W/HYDROMULCHER. NO TIE -DOWN REQUIRED. 1.25 TONS PER USE 90 GAL/ACRE TACKIFIER FOR STEEP SLOPES LESS THAN ACRE; 2:1; 120 GAL/ACRE FOR STEEPER THAN 2:1 IN. OF 2 IN. DEPTH I DO NOT USE ON SLOPES STEEPER THAN 6% N. OF 2 IN. DEPTH I DO NOT USE ON SLOPES STEEPER THAN 15% USE DOT SLOPE MIX FOR STEEP SLOPES. BENCHMARKS: FOUND 1.5" BRASS DISK WITH 2" BRASS DISK WITH PUNCH MARK PUNCH MARK IN CASE AT UNION IN CASE AT THE INTERSECTION OF AVENUE NORTHEAST AND NE 19TH NORTHEAST 19TH STREET AND 1 STREET, KNOWN AS CITY OF DUVALL, KNOWN AS CITY OF RENTON CONTROL POINT #716 RENTON CONTROL POINT #1996 NO. GRAB TENSILE STRENGTH (ASTIr1 04632) 200 LBS. MIN. GRAB TENSILE ELONGATION (ASTM D4632} 30% MAX. (WOVEN) CBR PUNCTURE STRENGTH (ASTM D6241) 495 LBS. MIN. AOS [ASTM D47511 20-45 N.S. STANDARD SIEVE SIZE] 2.2. DO NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLORIDE FOR CONSTRUCTION ENTRANCE STABILIZATION BECAUSE THESE PRODUCTS RAISE pH LEVELS IH STORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE IS PROHIBITED. 2.1 NOG FUEL (WOOD BASED MULCHI MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY A7 ANY TIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED DNTO PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED OWO PAVEMENT. 2.4- FENCING SHALL BE INSTALLED AS NECESSARY TO RFSTRIC7 TRAFFIC TO THE CONSTRUCTION ENTRANCE 2.5 WHENEVER POSSIBLE -THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM- COMPACTED SUBGRADE THIS CAN SUOTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE. 3. MAINTENANCE STANDARDS 3.1. QUARRY SPALLS SHALL BE ALIDED IF THE PAO IS NO LONGER IN ACCORDANCE WITH 1'HE SPECIFICATIONS. 3.2- IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEA313RE3 TO KEEP THE STREETS FREE OF SEOIMeNT $HAU„ IE USEQ. THIS MAY INCLUDt STREET $WEEPING, AN INCREASE IN THE DIMGN$IQNS OF THE ENTRAN(;E, OR THE IN5TALLATIQN OF A WHEEL WASH. IF WASHING IS USED, Fir SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAW TO A SEDIMENT TRAf3 OR POND 3 3. ANY SEDIMENTTHAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT "LEGTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE ANU THERE IS A TH73EAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STfiEETS, A SMALL SUMP MUST BE CONSTRUCTED. TKE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND OISCI•IARGED APPROPRIATELY. WASH WATER MUST 13E PLIMPM BACK ONTO THE SITE AND CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TD SURFACE WATERS. 3,4- ANY QUARRY $PALLS THAT AFtE LQQS€NED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY 3,5- IF VEHICLES ARE ENTERING OR EXITING THE SITES AT PAINTS OTHER THAN THE CONSTRUCTIA)M ENTRANCE(P). FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC. uNLESS oTt*RwISf N01f0, PRAWPNG 1$ NOT TO SCALE (NYSE STD. PIA N - 215,10 UR. PUBLIC WORKS APPZp'lfp' DEPARTMENT STABILIZED CONSTRUCTION ENTRANCE GAZ 9/28/2018 1 CAII EROSION CONTROL "WET SEASON" NOTES 1. ANY SITE WITH EXPOSED SOILS DURING THE WET SEASON (OCTOBER 1 TO APRIL 30) SHALL BE SUBJECT TO THE SPECIAL PROVISIONS BELOW. THESE SPECIAL PROVISIONS ARE REQUIRED IN ADDITION TO THE STANDARD ESC COVER MEASURES. THESE PROVISIONS INCLUDE COVERING ANY NEWLY SEEDED AREAS WITH MULCH AND IDENTIFYING AND SEEDING AS MUCH DISTURBED AREA AS POSSIBLE PRIOR TO SEPTEMBER 23 IN ORDER TO PROVIDE GRASS COVER FOR THE WET SEASON. 2. THE ALLOWED TIME THAT A DISTURBED AREA CAN REMAIN UNWORKED WITHOUT COVER MEASURES IS REDUCED TO TWO (2) DAYS, RATHER THAN SEVEN (7) DAYS. 3. STOCKPILES AND STEEP CUT AND FILL SLOPES ARE TO BE PROTECTED IF UNWORKED FOR MORE THAN 12 HOURS. 4. COVER MATERIALS (PLASTIC, MATTING, ETC.) SUFFICIENT TO COVER ALL DISTURBED AREAS SHALL BE STOCKPILED ON SITE. 5. ALL AREAS THAT ARE TO BE UNWORKED DURING THE WET SEASON SHALL BE SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. 6. MULCH IS REQUIRED TO PROTECT ALL SEEDED AREAS. 7. FIFTY LINEAR FEET OF SILT FENCE (AND THE NECESSARY STAKES) PER ACRE OF DISTURBANCE MUST BE STOCKPILED ON SITE. 8. CONSTRUCTION ROAD AND PARKING LOT STABILIZATION ARE REQUIRED FOR ALL SITES UNLESS THE SITE IS UNDERLAIN BY COARSE -GRAINED SOIL. ASBUILT REVISION 9. SEDIMENT RETENTION IS REQUIRED UNLESS NO OFFSITE DISCHARGE IS ANTICIPATED FOR THE SPECIFIED DESIGN FLOW. 10. PROPERLY INSTALLED SILT FENCING IS MANDATORY ALONG THE DOWNSLOPE OF ALL DISTURBED AREAS OF THE SITE. PERIMETER PROTECTION FILTERS RUNOFF AND REDUCES THE AMOUNT OF SEDIMENT THAT MAY LAVE THE SITE. 11. SURFACE WATER CONTROLS ARE REQUIRED UNLESS NO OFFSITE DISCHARGE IS ANTICIPATED FOR THE SPECIFIED DESIGN FLOW. 12. PHASING AND MORE CONSERVATIVE BMPS MUST BE EVALUATED FOR CONSTRUCTION ACTIVITY NEAR SURFACE WATERS. 13. ANY RUNOFF GENERATED BY DEWATERING SHALL BE TREATED THROUGH CONSTRUCTION OF A SEDIMENT TRAP WHEN THERE IS SUFFICIENT SPACE OR BY RELEASING THE WATER TO A WELL -VEGETATED, GENTLY SLOPING AREA. SINCE PUMPS ARE USED FOR DEWATERING, IT MAY BE POSSIBLE TO PUMP THE SEDIMENT -LADEN WATER WELL AWAY FROM THE SURFACE WATER SO THAT VEGETATION CAN BE MORE EFFECTIVELY UTILIZED FOR TREATMENT. A STRAW BALE FILTER SHALL BE PLACED AROUND THE DISCHARGE FROM THE DEWATERING PUMP. IF THERE IS NOT SPACE FOR A SEDIMENT TRAP OR 25 FEET OF SUITABLE VEGETATION, OTHER FILTRATION METHODS SHALL BE REQUIRED. 14. THE FREQUENCY OF MAINTENANCE REVIEW SHOULD BE INCREASED FROM WEEKLY TO DAILY WHERE WARRANTED. SURVEYED: TSL DESIGNED: DSC DRAWN: DSC EN 1 1 /19/21 DD CHECKED: DID BY DATE APPR APPROVED: DID SCALE: N/A ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM 2-x2- 14 GAUGE WIRE, OR EDUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC - --I1- --- --'- ------ - sMAx. -' POST $AAC1N{3 MAY BE INCREASED J {'kd' MIN. TRENCH TO8' IF WIRE BACKING IS USED ,ul BACHFILL TRENCH WITH NATIVE SOIL OR 3A" TO 1-V2' WASHED GRAVEL 2"x4" WOOD POSTS, STEEL FENCE POSTS, OR EQUIVALENT (TYP-) 2' MIN. NOTE: CONTRACTOR SHALL USE BRIGHT ORANGE SILT FENCE IN ALL LOCATIONS. NOTES: 1. CQHDRIDNS OF 135E 1.1- SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. IZ SILT FENCE IS NOT INTENDED 70 TREAT CONCENTRATED FLOWS. NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TF44P OR POND. Z DESIGN AND INSTALLATION SPEGIFTCATIINS 2.1. THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE. ADS (ASTM L74751I 30400 $1EVE $k2E 18.59-4.1SmmI FQR SILT FILM 54-F90 SIEVE SIZE 10.30-0.15mmj FOR OTHER FABRICS WATER PERMTTIVFTY(A$TM D4491) 0-02SEC�'M[NIMUM GRAB TENSILE STRENGTH (ASTM D4632} 1130 LBS. MIN. FOR EXTRA STRENGTHFABRIC 100 LB.S. MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM 34632) 30%MAX. (WOVEN} ULTRAVIOLET RESISTANCE (ASTM 043M5 70%MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE WIRE BLACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE 2-3. WHERE THE FENCE IS IN$TALLEC, THE 94OPE SHALL NOT BE STEEPER THAN 2R..IV 2.4. It: A TYPICAL SILT FENCE IS USED, THE STANDARD 4'X4' TRFNC14 MAY 13F REnUCED AS LONG AS THE 9OTIrCYM S INCHES OR THE SILT PENCE PAMIC IS WELL RURIED AND SECURE IN A TRENCH THAT STABILI2ES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE 2.5, FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE, 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY. 5.2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, T+IEV MUST BE INTERCEPTED ANTS CONVEYED TO A SEDIMENT TRAP OR POND. 3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR 31GNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING 0HANNELIZA71ON OF FLOWS PARALLEL TO THE FENCE IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT. 3.4. SEDIMENT MUST BE REMOVED WHEN SEDIMET T 15 6 INCHES HIGH. 3-5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAV30LET BREAKDOWN. IT SHALL BE REPLACED. UNLE5$ O'hIFRW15E No1E0, DRAWING IS NOTIO SCALE (NTSI STD. PLAN - 214.00 URr DEPARTMENT CAAZ PUBLIC WORKS SILT FENCE P 912912019 1 � W.1� W,x1. CJ mnlln� : • 1. THE FILTER FABRIC SHALL BE PURCHASED IN A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID USE OF JOINTS. WHEN JOINTS ARE NECESSARY, FILTER CLOTH SHALL BE SPLICED TOGETHER ONLY AT A SUPPORT POST, WITH A MINIMUM 6-INCH OVERLAP, AND BOTH ENDS SECURELY FASTENED TO THE POST 2. THE FILTER FABRIC FENCE SHALL BE INSTALLED TO FOLLOW THE CONTOURS (WHERE FEASIBLE). THE FENCE POSTS SHALL BE SPACED A MAXIMUM OF 6 FEET APART AND DRIVEN SECURELY INTO THE GROUND (MINIMUM OF 30 INCHES) 3. A TRENCH SHALL BE EXCAVATED, ROUGHLY 8 INCHES WIDE AND 12 INCHES DEEP, UPSLOPE AND ADJACENT TO THE WOOD POST TO ALLOW THE FILTER FABRIC TO BE BURIED 4. WHEN STANDARD STRENGTH FILTER FABRIC IS USED, A WIRE MESH SUPPORT FENCE SHALL BE FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS USING HEAVY DUTY WIRE STAPLES AT LEAST 1 INCH LONG, TIE WIRES OR HOG RINGS. THE WIRE SHALL EXTEND INTO THE TRENCH A MINIMUM OF 4 INCHES AND SHALL NOT EXTEND MORE THAN 36 INCHES ABOVE THE ORIGINAL GROUND SURFACE 5. THE STANDARD STRENGTH FILTER FABRIC SHALL BE STAPLED OR WIRED TO THE FENCE, AND 20 INCHES OF THE FABRIC SHALL BE EXTENDED INTO THE TRENCH. THE FABRIC SHALL NOT EXTEND MORE THAN 36 INCHES ABOVE THE ORIGINAL GROUND SURFACE. FILTER FABRIC SHALL NOT BE STAPLED TO EXISTING TREES 6. WHEN EXTRA STRENGTH FILTER FABRIC AND CLOSE POST SPACING ARE USED, THE WIRE MESH SUPPORT FENCE MAY BE ELIMINATED. IN SUCH A CASE, THE FILTER FABRIC IS STAPLED OR WIRED DIRECTLY TO THE POSTS WITH ALL OTHER PROVISIONS OF STANDARD NOTE 5 APPLYING 7. THE TRENCH SHALL BE BACKFILLED WITH 3/4-INCH MINIMUM DIAMETER WASHED GRAVEL 8. FILTER FABRIC FENCES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFUL PURPOSE, BUT NOT BEFORE THE UPSLOPE AREA HAS BEEN PERMANENTLY STABILIZED 9. FILTER FABRIC FENCES SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REQUIRED REPAIRS SHALL BE MADE IMMEDIATELY • CITY OF o' RENTON Planning/Building/Public Works Dept. R-409731 11-19-21 ci E V i C N .� � O t U-) i !` W N N M U) Q 00 N :3 C 0') Q N U) j I` L0 a-+ 1114 cMa W O V � r (1) Y Nri �lt IN COMPLIANCE WITH CITY OF RENTON STANDARDS ASBUILT TESC NOTES AND DETAILS DALPAY SHORT PLAT DALPAY PROPERTIES, LLC. 4033 N.E. SUNSET BOULEVARD RENTON, WA 98059 Q J 0-00 00 ry- r O Z 7® Z DATE: 1 1 /19/2021 c� m FIELDBOOK: O PAGE: DRAWING NO: W J SHEEP: C4 OF: 18 Q fn