HomeMy WebLinkAboutR-403219►i CONIC, CURB, EXTRUDED OR POURED IN PLACE OR NO CURB AT ALL CONCRETE SIDEWALK A,C. PAVING OR OTHER I PAVING SURFACE rl 6, MINUS CRUSHED V.—T ROCKSLOPE zo DN p.:.1 FOOT MINIMUM " PAST CURB o COMPACTED SUB-BASEo 80 °.•' 0 0 0 _ 0, 1- Z -III-III-III-III-I I ��: -'f 1- I LOCATION TAPE III —III —III —III —III Z'.L I , 1.1?I. 6" ABOVE PIPE N SLEEVE PIPE TWO TIMES THE NOTE: SIZE OF INSERTED PIPE (PROVIDE A SLEEVE FOR WATER PIPING AND A SECOND SLEEVE FOR WIRE) VERIFY METHOD OF COMPACTION WITH SOILS ENGINEER OR GENERAL CONTRACTOR SLEEVING DETAIL N.T.S. PIPE SIZING CHART PIPE SIZE GPM TO GPM 3/ 0 10 1" 11 16 1-1/4" 17 26 1-1/211 27 35 2" 36 55 2-1/2" 56 80 BASED ON PVC CLASS 200 IPS PLASTIC PIPE 5' PER SECOND VEL❑CITIES VALVE SIZING CHART VALVE SIZE GPM TO GPM 1" 0 17 1-1/211 18 35 211 36 55 BASED ❑N RAINBIRD PEB SERIES VALVES 0 30—INCH LINEAR LENGTH OF WIRE, COILED �2 WATER PROOF CONNECTION (1 OF 2) ID TAG 0 REMOTE CONTROL VALVE: RAIN BIRD PEB VALVE BOX WffH COVER: 12—INCH SIZE FINISH GRADE/TOP OF MULCH �7 PVC SCH B® NIPPLE (CLOSE) PVC SCH 40 ELL PVC SCH B® NIPPLE (LENGTH AS REQUIRED) 1O BRICK (1 OF 4) 11 PVC MAINLINE PIPE 12 SCH BO NIPPLE (2—INCH LENGTH, HIDDEN) AND SCH 40 ELL 13 PVC SCH 40 TEE OR ELL 14 PVC SCH 40 MALE ADAPTER 15 PVC (LATERAL PIPE 16 3.0—INCH MINIMUM( DEPTH OF 3/4—INCH WASHED GRAVEIL PEB VALVE DETAIL STATE OF Landscape WREEGISTEGISTEREEDD ASHINGTON DS I Architectural �� LANDSCAPE ARCHITECT Services PO. BOX 11134 TACOMA, WA., 98411 FRANK FICATWILLIAM O. 255L CERTIFICATE N0. 255 P; 253-671-2221 / EM; FWBLAS@AOL.COM / FRANK.BUSHELLI@GMAIL.COM EXP; 1-20-2019 PIPE (SIZE AND LENGTH AS REQUIRED) FINISH GRADE/TOP OF MULCH VALVE BOX WITH COVER 8CM MINIMUM DEPTH OF WASHED GRAVEL BRICK (1 OF 2) GATE VALVE WITH SOLID WEDGE, NON -RISING STEM (USE EITHER THREADED, PUSH -ON, OR MECHANICAL JOINT ENDS) ELL PIPE (1 OF 2, LENGTH AS REQUIRED) SERVICE TEE MAINLINE PIPE GATE VALVE DETAIL CITY APPROVED VAULT W/ LID GATE VALVE OR ANGLE VALVE PRESSURE REDUCING SHUT FOFF VALVE ( IF REQUIRED) Z N CITY APPROVED -DOUBLE CHECK VALVE ASSEMBLY INSTALL PLUGS IN F TEST COCKS (TYP.) QUICK COUPLING VALVE FOR WINTER BLOWOUT MASTER VALVE I (IF REQUIRED) -a ,� o - .o a oo � o. o a o $ o°°� 8 o a d� 9 o p o� S �o� 0 0% 8° oa° 0 0 FINISH GRADE DRAIN ROCK (TYPICAL) MIN. 12" DEPTH {:::::: GALV. PIPE . THREADED CAPPED STUB OUT 36" LONG SS ROD WITH ......... FROM METER 2 SS GEAR CLAMPS 12' ..... 18' ..................... BACKFILL SECTION VIEW SPRINKLER LATERAL WILKINS 550 PRESSURE PRESSURE GUAGE REGULATION VALVE IF STATIC PRESSURE IS MAIN SUPPLY LINE LINE SIZE IN EXCESS OF 80PSI GATE VALVE 3/4' DRAIN VALVE :::::0::::: FEBC❑ DDUBL CHECK VALV 1' QUICK COUPLER VALVE CONTROL AND NOTE: CONTROL AND NEUTRAL TAP INT❑ DOMESTIC MASTER NEUTRAL CONDUCTORS INSTALLED CONDUCTORS WITH LA BE WATER SERVICE R / // VALVE MINIMUM OF 18' EARTH COVER IRRIGATION METER / MAIN LINE TRENCHING DETAIL (DSINGLE-OUTLET EMITTER: RAIN BIRD XERI-BUG EMITTERS XB-20PC 2.0 GPH OR .0333 GPM O2 1/4-INCH TUBING STAKE: RAIN BIRD TS-025 O3 1/4-INCH VINYL DISTRIBUTION TUBING: RAIN BIRD DT-025 O4 TOP OF MULCH O5 INSERT FITTING: RAIN BIRD 1/4-INCH SELF -PIERCING BARB CONNECTOR SPB-025 O6 PE PIPE: RAIN BIRD DISTRIBUTION TUBING XT-700-100 70 FINISH GRADE O8 NOT SHOWN USE END CAP AT END XT-700-100 PIPE RUN NOTE: 1. USE RAIN BIRD TOOL XM—TOOL TO INSERT BARB CONNECTOR DIRECTLY INTO XERI—TUBE. 2. USE ONE OUTLET EMITTER UNIT SET—UP PER SHRUB AND TWO UNITS PER TREE WATER EMITTER UNITS SH GRADE/TOP OF MULCH '—UP SPRAY SPRINKLER: ,I BIRD 1804 SCH 80 NIPPLE JGTH AS REQUIRED) SCH 40 ELL SCH 40 STREET ELL SCH 80 NIPPLE JGTH AS REQUIRED) SCH 40 STREET ELL LATERAL PIPE r'VU SCH 40 TEE OR ELL 1804 POP-UP SPRINKLER SURVEYED: SURVEYED DESIGNED: DESIGNED DRAWN: DRAWN CHECKED: CHECKED NO. REVISION BY DATE APPR APPROVED: APPROVED SCALE: SCALE ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL, NAVD 1988 HORIZONTAL NAD 1983/1991 DATU M M1LI ' WATER FLOW TO ZONE DOMESTIC SERVICE PLAN VIEW LINE WATER SERVICE MAIN LINE POINT OF CONNECTION NOT TO SCALE VING 01 PVC SCH 80 NIPPLE (CLOSE) O2 VALVE BOX WITH COVER: 24-INCH SIZE O3 ID TAG: RAIN BIRD SERIES I D TAG O4 WATER PROOF CONNECTION RAIN BIRD SPLICE-1 (1 OF 2) O5 30-INCH LINEAR LENGTH OF WIRE, COILED O FINISH GRADE O7 TOP OF MULCH O8 PVC SCH 40 COUPLING O9 PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) 10 PVC SCH 40 ELL 11 PVC SCH 80 NIPPLE (2-INCH LENGTH, HIDDEN) AND PVC SCH 40 ELL 12 PVC SCH 40 TEE OR ELL 13 BRICK (1 OF 4) 14 3.0-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL 15 PVC MAINLINE 16 CONTROL ZONE KIT: RAIN BIRD MODEL XCZ-10000M 17 PVC SCH 80 UNION FOR SERVICING ASSEMBLY 18 PVC SCH 40 MALE ADAPTER 19 PVC LATERAL PIPE XER GAT ON CONTROL ZONE KIT NOT TO SCALE R-40321 9 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CURRENT PLANNING amorganroth 10/23/2018 DATE: CITY OF CHRISTELLE RIDGE 2 Fl°DBOOK: 8 RENTON PAGE: SE 95TH WAY RENTON WASHINGTON DRAWING NO: Planning/Building/Public Works Dept. LANDSCAPE PLANTING PLAN I SHEET:_ OF: U ng i` L