HomeMy WebLinkAboutR-403219►i
CONIC, CURB, EXTRUDED OR
POURED IN PLACE
OR NO CURB AT ALL
CONCRETE SIDEWALK
A,C. PAVING OR OTHER I
PAVING SURFACE rl 6,
MINUS CRUSHED V.—T
ROCKSLOPE zo DN p.:.1 FOOT MINIMUM
" PAST CURB o
COMPACTED SUB-BASEo 80 °.•'
0 0 0 _ 0, 1- Z
-III-III-III-III-I I ��: -'f 1- I LOCATION TAPE
III —III —III —III —III Z'.L I , 1.1?I. 6" ABOVE PIPE N
SLEEVE PIPE TWO TIMES THE
NOTE: SIZE OF INSERTED PIPE
(PROVIDE A SLEEVE FOR WATER PIPING AND A SECOND SLEEVE FOR WIRE)
VERIFY METHOD OF COMPACTION WITH SOILS ENGINEER OR GENERAL CONTRACTOR
SLEEVING DETAIL
N.T.S.
PIPE SIZING
CHART
PIPE SIZE
GPM
TO GPM
3/
0
10
1"
11
16
1-1/4"
17
26
1-1/211
27
35
2"
36
55
2-1/2"
56
80
BASED ON PVC CLASS
200 IPS PLASTIC PIPE
5' PER SECOND VEL❑CITIES
VALVE SIZING CHART
VALVE SIZE
GPM TO GPM
1"
0 17
1-1/211
18 35
211
36 55
BASED ❑N RAINBIRD
PEB SERIES VALVES
0 30—INCH LINEAR LENGTH OF
WIRE, COILED
�2 WATER PROOF CONNECTION
(1 OF 2)
ID TAG
0 REMOTE CONTROL VALVE:
RAIN BIRD PEB
VALVE BOX WffH COVER:
12—INCH SIZE
FINISH GRADE/TOP OF MULCH
�7 PVC SCH B® NIPPLE (CLOSE)
PVC SCH 40 ELL
PVC SCH B® NIPPLE
(LENGTH AS REQUIRED)
1O BRICK (1 OF 4)
11 PVC MAINLINE PIPE
12 SCH BO NIPPLE (2—INCH
LENGTH, HIDDEN) AND
SCH 40 ELL
13 PVC SCH 40 TEE OR ELL
14 PVC SCH 40 MALE ADAPTER
15 PVC (LATERAL PIPE
16 3.0—INCH MINIMUM( DEPTH OF
3/4—INCH WASHED GRAVEIL
PEB VALVE DETAIL
STATE OF
Landscape WREEGISTEGISTEREEDD
ASHINGTON
DS I Architectural �� LANDSCAPE ARCHITECT
Services
PO. BOX 11134 TACOMA, WA., 98411 FRANK FICATWILLIAM O. 255L
CERTIFICATE N0. 255
P; 253-671-2221 / EM; FWBLAS@AOL.COM / FRANK.BUSHELLI@GMAIL.COM EXP; 1-20-2019
PIPE (SIZE AND LENGTH AS REQUIRED)
FINISH GRADE/TOP OF MULCH
VALVE BOX WITH COVER
8CM MINIMUM DEPTH OF
WASHED GRAVEL
BRICK (1 OF 2)
GATE VALVE WITH SOLID WEDGE,
NON -RISING STEM (USE EITHER
THREADED, PUSH -ON, OR MECHANICAL
JOINT ENDS)
ELL
PIPE (1 OF 2, LENGTH AS REQUIRED)
SERVICE TEE
MAINLINE PIPE
GATE VALVE DETAIL
CITY APPROVED VAULT W/ LID
GATE VALVE
OR ANGLE VALVE PRESSURE REDUCING SHUT FOFF VALVE
( IF REQUIRED)
Z
N
CITY APPROVED
-DOUBLE CHECK
VALVE ASSEMBLY
INSTALL PLUGS IN
F TEST COCKS (TYP.)
QUICK COUPLING VALVE
FOR WINTER BLOWOUT
MASTER VALVE
I (IF REQUIRED)
-a ,� o - .o
a oo � o. o a o $ o°°� 8 o a d� 9 o p o� S �o� 0 0% 8° oa° 0 0
FINISH GRADE DRAIN ROCK (TYPICAL)
MIN. 12" DEPTH
{:::::: GALV. PIPE
. THREADED CAPPED STUB OUT 36" LONG SS ROD WITH
.........
FROM METER 2 SS GEAR CLAMPS
12'
.....
18' .....................
BACKFILL
SECTION VIEW
SPRINKLER LATERAL
WILKINS 550 PRESSURE PRESSURE GUAGE
REGULATION VALVE IF
STATIC PRESSURE IS
MAIN SUPPLY LINE LINE SIZE IN EXCESS OF 80PSI
GATE VALVE 3/4' DRAIN VALVE
:::::0::::: FEBC❑ DDUBL
CHECK VALV 1' QUICK COUPLER VALVE
CONTROL AND NOTE: CONTROL AND NEUTRAL TAP INT❑ DOMESTIC MASTER
NEUTRAL CONDUCTORS INSTALLED CONDUCTORS WITH LA BE WATER SERVICE R / // VALVE
MINIMUM OF 18' EARTH COVER IRRIGATION METER / MAIN LINE
TRENCHING DETAIL
(DSINGLE-OUTLET EMITTER: RAIN BIRD
XERI-BUG EMITTERS XB-20PC
2.0 GPH OR .0333 GPM
O2 1/4-INCH TUBING STAKE:
RAIN BIRD TS-025
O3 1/4-INCH VINYL DISTRIBUTION
TUBING: RAIN BIRD DT-025
O4 TOP OF MULCH
O5 INSERT FITTING: RAIN BIRD
1/4-INCH SELF -PIERCING
BARB CONNECTOR SPB-025
O6 PE PIPE: RAIN BIRD
DISTRIBUTION TUBING XT-700-100
70 FINISH GRADE
O8 NOT SHOWN USE END CAP AT END
XT-700-100 PIPE RUN
NOTE:
1. USE RAIN BIRD TOOL XM—TOOL TO INSERT BARB CONNECTOR
DIRECTLY INTO XERI—TUBE.
2. USE ONE OUTLET EMITTER UNIT SET—UP PER SHRUB AND TWO UNITS PER TREE
WATER EMITTER UNITS
SH GRADE/TOP OF MULCH
'—UP SPRAY SPRINKLER:
,I BIRD 1804
SCH
80
NIPPLE
JGTH
AS
REQUIRED)
SCH
40
ELL
SCH
40
STREET ELL
SCH
80
NIPPLE
JGTH
AS
REQUIRED)
SCH 40 STREET ELL
LATERAL PIPE
r'VU SCH 40 TEE OR ELL
1804 POP-UP SPRINKLER
SURVEYED:
SURVEYED
DESIGNED:
DESIGNED
DRAWN:
DRAWN
CHECKED:
CHECKED
NO. REVISION BY DATE APPR APPROVED:
APPROVED
SCALE:
SCALE
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL, NAVD 1988
HORIZONTAL NAD 1983/1991
DATU M
M1LI '
WATER FLOW TO ZONE
DOMESTIC SERVICE PLAN VIEW
LINE
WATER SERVICE
MAIN LINE
POINT OF CONNECTION
NOT TO SCALE
VING
01 PVC SCH 80 NIPPLE
(CLOSE)
O2 VALVE BOX WITH COVER:
24-INCH SIZE
O3 ID TAG: RAIN BIRD SERIES
I D TAG
O4 WATER PROOF CONNECTION
RAIN BIRD SPLICE-1
(1 OF 2)
O5 30-INCH LINEAR LENGTH
OF WIRE, COILED
O FINISH GRADE
O7 TOP OF MULCH
O8 PVC SCH 40 COUPLING
O9 PVC SCH 80 NIPPLE
(LENGTH AS REQUIRED)
10 PVC SCH 40 ELL
11 PVC SCH 80 NIPPLE (2-INCH
LENGTH, HIDDEN) AND
PVC SCH 40 ELL
12 PVC SCH 40 TEE OR ELL
13 BRICK (1 OF 4)
14 3.0-INCH MINIMUM DEPTH OF
3/4-INCH WASHED GRAVEL
15 PVC MAINLINE
16 CONTROL ZONE KIT: RAIN BIRD
MODEL XCZ-10000M
17 PVC SCH 80 UNION FOR
SERVICING ASSEMBLY
18 PVC SCH 40 MALE ADAPTER
19 PVC LATERAL PIPE
XER GAT ON CONTROL ZONE KIT
NOT TO SCALE
R-40321 9
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING
amorganroth 10/23/2018
DATE:
CITY OF CHRISTELLE RIDGE 2 Fl°DBOOK: 8
RENTON PAGE:
SE 95TH WAY RENTON WASHINGTON DRAWING NO:
Planning/Building/Public Works Dept.
LANDSCAPE PLANTING PLAN I SHEET:_ OF: