HomeMy WebLinkAboutT-403201w
0
rr
Lu
w
I—
Cn
U
T
N
I—
w
w
Cn
STREET LIGHT ASBUILTS
*INFORMATION PROVIDED BY HOLMVIG
DEWITT GALLION AND ASSOCIATES
ADDRESS: 139 N. PIONEER ST. BUCKLEY,
WA PHONE: (360) 825-6963
PORTION OF THE NW 1 /4 OF THE NW 1 /4
SECTION 3, TOWNSHIP 23 NORTH, RANGE 5 EAST,
CITY OF RENTON, STATE OF WASH I N GTON
� S TREE T LIGHTS
10' UTL AND
CW EAEMENT
5' SIDEWALK — " 0
8' LANDSCAPE STRIP
VERT. CURB &
GUTTER
i
W.M.
LEGEND
® TYPE "B" JUNCTION BOX
LUMINAIRE
20 0 10 20 40
_ — CONDUIT
GRAPHIC SCALE
STREET LIGHT CONTACTOR CABINET SCALE:1"=20'
z_ O INSTALL SPR51-14-850—COLTX WITH LUMINAIRE PHOTO CELL.
J 10' UTL AND
3::
21' R/W CW EAEMENT
O INSTALL TYPE "B" JUNCTION BOX
4"MIN. CLASS "B" ASPHALTIC CONCRETE
PAVEMENT— 2-2" LIFTS REQUIRED
6"MIN. CRUSHED SURFACING TOP COURSE
CRUSHED SURFACING BASE COURSE TO BE
DETERMINED BY FIELD CONDITIONS
OINSTALL STREET LIGHT CABINET 120/240 VOLT
TYPE III WITH AN ENCLOSED METER BASE
(NEW P.S.E. REQUIREMENT NO. #0110
OINSTALL TYPE III MEDIUM CUTOFF DISTRIBUTION LUMINAIRE AND FLAT
GLASS REFRATOR PER CITY OF NEW CASTLE REQUIREMENTS.
5O FOLLOW CITY OF RENTON STD PLANS AS ATTACHED
LUMINAIRE SCHEDULE
LUMINAIRE POLE
NUMBER POLE LOCATION LATITUDE/ MOUNT
ID LONGITUDE HEIGHT LUMINAIRE TYPE—RENETON STD PLAN 117
NO*
LP-1 I ISTA 0+53.81, 19.4 'LT
LP-2 I I STA 1+07 , 19.15' RT
LP-3 I I STA 1+62 , 19.02' LT
LP-4 I I STA 2+13 , 17.91' RT
LP-5
STA
2+52.79,
19.0'
LT
LP-6
STA
3+07.79,
19.0'
RT
LP-7 I ISTA 3+24.23, 46.87' L
LP-8 I ISTA 3+50.05, 72.26' L
LP-9 I ISTA 3+80.65, 30.91' LT
LP-10 I ISTA 3+78.40, 17.96' RT
LP-11 I ISTA 4+43.64, 18.64' LT
14.' ICY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX
14.' I CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX
14.' ICY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX
14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX
14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX
14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX
14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX
14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX
14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX
14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX
14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX
LP-12 STA 4+98.17, 19.0' RT 14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX
LP-13 STA 5+51.20, 19.14' LT 14.' CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX
* POLE ID NUMBERING TO BE PROVIDED BY CITY AT TIME OF CONTRUCTION
TO BE PROVIDED AND INSTALLED BY CONTRACTOR
CONDUIT AND WRING
SCHEDULE
RUN NO.
CONDUIT
WIRING
ZL1
2"
PVC SCH.
40
2
— #8 T.H. W. COPPER
— #8 BARE GROUND
2"
PVC SCH.
80
3
— #2 (SERVICE)
2"
PVC SCH.
40
2
— #8 T.H. W. COPPER
3
1
— #8 BARE GROUND
42"
P VC SCH.
80
2
— #8 T.H. W. COPPEAR
1
— #8 BARE GROUND
2"
P VC SCH.
80
2
1
— #8 T.H. W. COPPER
— #8 BARE GROUND
2
— #14 T.H. W. COPPER
T-403201
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
Pacific ��� �1.1.�.".�11�� °E w � � 5��: SCALE,NOTED IZ NAw'»� CHRISTELLE RIDGE �M
HORrzoNTAL NAD/1ae1 ' CITY 0 F 3-22-2018
Z DESIGNED: J. HOPPER SOUND BLDG & DEVELOPMENT, LLC Fl°'E,
Des. Jfj1 RENTON
P��
J� `� -0 02 REVISION AS PER CITY COMMENTS ON 09/05/18 PJP 9/11 /18 JH °mow"' P. PATEL ONE INCDUM 21222 132 N D AVE SE DRAWING No:
H AT
1 REVISION AS PER CITY COMMENTS ON 06/18/18 PJP 8/01 /18 JH CHECKED:
r Civil Enyineetiny s..= S J. HOPPER AT FULL SCALE Planning/Building/Public Works Dept. KENT, WA 98042 21
�€ PlanningCQn uhEw1s.:: IF NOT ONE INCH
A L �' 0� t+YZA N0. REVISION BY DATE APPR A 0" J. HOPPER SCALE ACCORDINGLY STREET LIGHT PLAN 01 '� 21 °�24