Loading...
HomeMy WebLinkAboutzT-4032Setw 0 rr Lu w I— Cn U T N I— w w Cn STREET LIGHT ASBUILTS *INFORMATION PROVIDED BY HOLMVIG DEWITT GALLION AND ASSOCIATES ADDRESS: 139 N. PIONEER ST. BUCKLEY, WA PHONE: (360) 825-6963 PORTION OF THE NW 1 /4 OF THE NW 1 /4 SECTION 3, TOWNSHIP 23 NORTH, RANGE 5 EAST, CITY OF RENTON, STATE OF WASH I N GTON � S TREE T LIGHTS 10' UTL AND CW EAEMENT 5' SIDEWALK — " 0 8' LANDSCAPE STRIP VERT. CURB & GUTTER i W.M. LEGEND ® TYPE "B" JUNCTION BOX LUMINAIRE 20 0 10 20 40 _ — CONDUIT GRAPHIC SCALE STREET LIGHT CONTACTOR CABINET SCALE:1"=20' z_ O INSTALL SPR51-14-850—COLTX WITH LUMINAIRE PHOTO CELL. J 10' UTL AND 3:: 21' R/W CW EAEMENT O INSTALL TYPE "B" JUNCTION BOX 4"MIN. CLASS "B" ASPHALTIC CONCRETE PAVEMENT— 2-2" LIFTS REQUIRED 6"MIN. CRUSHED SURFACING TOP COURSE CRUSHED SURFACING BASE COURSE TO BE DETERMINED BY FIELD CONDITIONS OINSTALL STREET LIGHT CABINET 120/240 VOLT TYPE III WITH AN ENCLOSED METER BASE (NEW P.S.E. REQUIREMENT NO. #0110 OINSTALL TYPE III MEDIUM CUTOFF DISTRIBUTION LUMINAIRE AND FLAT GLASS REFRATOR PER CITY OF NEW CASTLE REQUIREMENTS. 5O FOLLOW CITY OF RENTON STD PLANS AS ATTACHED LUMINAIRE SCHEDULE LUMINAIRE POLE NUMBER POLE LOCATION LATITUDE/ MOUNT ID LONGITUDE HEIGHT LUMINAIRE TYPE—RENETON STD PLAN 117 NO* LP-1 I ISTA 0+53.81, 19.4 'LT LP-2 I I STA 1+07 , 19.15' RT LP-3 I I STA 1+62 , 19.02' LT LP-4 I I STA 2+13 , 17.91' RT LP-5 STA 2+52.79, 19.0' LT LP-6 STA 3+07.79, 19.0' RT LP-7 I ISTA 3+24.23, 46.87' L LP-8 I ISTA 3+50.05, 72.26' L LP-9 I ISTA 3+80.65, 30.91' LT LP-10 I ISTA 3+78.40, 17.96' RT LP-11 I ISTA 4+43.64, 18.64' LT 14.' ICY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX 14.' I CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX 14.' ICY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX 14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX 14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX 14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX 14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX 14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX 14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX 14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX 14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX LP-12 STA 4+98.17, 19.0' RT 14.' 1 CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX LP-13 STA 5+51.20, 19.14' LT 14.' CY17T4—VS3AR-3L3-44W-4000K—GCY06P—PC—RAL9005TX * POLE ID NUMBERING TO BE PROVIDED BY CITY AT TIME OF CONTRUCTION TO BE PROVIDED AND INSTALLED BY CONTRACTOR CONDUIT AND WRING SCHEDULE RUN NO. CONDUIT WIRING ZL1 2" PVC SCH. 40 2 — #8 T.H. W. COPPER — #8 BARE GROUND 2" PVC SCH. 80 3 — #2 (SERVICE) 2" PVC SCH. 40 2 — #8 T.H. W. COPPER 3 1 — #8 BARE GROUND 42" P VC SCH. 80 2 — #8 T.H. W. COPPEAR 1 — #8 BARE GROUND 2" P VC SCH. 80 2 1 — #8 T.H. W. COPPER — #8 BARE GROUND 2 — #14 T.H. W. COPPER T-403201 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Pacific ��� �1.1.�.".�11�� °E w � � 5��: SCALE,NOTED IZ NAw'»� CHRISTELLE RIDGE �M HORrzoNTAL NAD/1ae1 ' CITY 0 F 3-22-2018 Z DESIGNED: J. HOPPER SOUND BLDG & DEVELOPMENT, LLC Fl°'E, Des. Jfj1 RENTON P�� J� `� -0 02 REVISION AS PER CITY COMMENTS ON 09/05/18 PJP 9/11 /18 JH °mow"' P. PATEL ONE INCDUM 21222 132 N D AVE SE DRAWING No: H AT 1 REVISION AS PER CITY COMMENTS ON 06/18/18 PJP 8/01 /18 JH CHECKED: r Civil Enyineetiny s..= S J. HOPPER AT FULL SCALE Planning/Building/Public Works Dept. KENT, WA 98042 21 �€ PlanningCQn uhEw1s.:: IF NOT ONE INCH A L �' 0� t+YZA N0. REVISION BY DATE APPR A 0" J. HOPPER SCALE ACCORDINGLY STREET LIGHT PLAN 01 '� 21 °�24 W CD 0 rr W J J W I— Cn 2 U N N I— W W 2 Cn STREET LIGHT ASBUILTS *INFORMATION PROVIDED BY HOLMVIG DEWITT GALLION AND ASSOCIATES ADDRESS: 139 N. PIONEER ST. BUCKLEY, WA PHONE: (360) 825-6963 Pacific En r j'.rj _r'-,y11j r � r,r!7 Des!js_rj, I ' r Civil Fngir�e+�tiri J �€ Planning Can mJ-Lun-_t ; AL E PORTION OF THE NW 1 /4 OF THE NW 1 /4 SECTION 3, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. CITY OF RENTON, STATE OF WASH I N GTON SEE SHEET 18 1 02 1 REVISION AS PER CITY COMMENTS ON 06/18/18 1 PJP 9/12/18 JH 1 IREVISION AS PER CITY COMMENTS ON 06/18/18 1 PJP 8/01 /18 JH t+%tj NO. I REVISION BY I DATE I APPR SURVEYED: DESIGNED: J. HOPPER DRAWN: P. PATEL CHECKED: J. HOPPER APPROVED: J. HOPPER NOTES: 1. EASEMENT IS REQUIRED TO BE PROVIDED TO THE CITY FOR ANY STREET LIGHT LOCATED OUTSIDE THE PUBLIC RIGHT OF WAY. NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL• NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM ASBUILTS CITY OF RENTON Planning/Building/Public Works Dept. 20 0 10 20 40 GRAPHIC SCALE SCALE: 1a=20' T-403202 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CHRISTELLE RIDGE SOUND BLDG & DEVELOPMENT, LLC 21222 132ND AVE SE KENT, WA 98042 STREET LIGHT PLAN 02 DATE 3-22-2018 FlELDBOOK: PAGE DRAWING NO: 22 22 24 rW V rr W J J W r� V J rr U M N I— W W V ) Lq c t ].e A�..-3 -Ax3 �-�.>E'AC'QH •• I PRE1W SOIKS IC1'TTN) LLD FOSS-FCp I.UAMART ['AMTrAIE PER PLAry� +.000C CUT, *"_277V A SkRS: LDI*nk w-67 Z. VilW i• COMMI UNLESS f ZVE LY SPA= mm Apl'g1C um] By `Mw STATLO OINFPRSC TA TOR APPROI[L EOIJAL). 6ELS1 BARS CLNTER CONDUITZEpix 14 m[ IN,P,D SML BE rqAlm 9M>,I CMa[ PA PqR MOTOR O)-T DAM.P1AOE DFTAL_ hHO SHEET] F'wS IEIAIRAL EA0o1 LOCATED H 1H[ fOUHDA���!{_sFcnorT FIATMIZ Y DOI":IRE$ CRDLAO POI[ TO 5TAU ORMUII3 CAP rDW[ALR01 PLANS 3/4' dAMWFM IMP)s I _V MAN R[Li1N &Kkft1, Fpl ST4iT LIOST 7'-P' MIA LI16H1 P,MO� DECAL PAIE1CRr ■,IROINL OEIAII_ IATDI TO Olr 0 E017C R[ CIDUDtAT wwm Sm PIAM 171 y41 EEWOM ([AUDANIN ON DS ammulito OdJ w 0AfX1i1 i'� -O ROTED 91/PE. S' p/4M, M HOTS ■ Ir µ RAM Nino" RME a1s-r+-BD.�RVIDO§rx-rRia1 a - As ElAitq MOM LOR APMWM EOPAr) &.E RI SPACM r LPN ml PROACh01 xstAu II OIL, ARLrwE'17' pA ORAA'O I'. 2c ..I TORE E1N�oIP NLwr {$LNDAf1CN DETAIL ur OA HaE 1�ISTECL PLAK ra I lKrwLz eaT �ca PAI•ER L44 RLFOE DECORATIVE ALSAINLIR CLAN[ HELL DCTAIL ll15 WE.1 BAY TDSER 110461 [v m w MCH{QjLBCLi TEMPLATE [IETAIL (M APPAOHEO ear) POLE�ASE DETAdL Su PUE Amm DOTAL IINL ANCHOR RUT. + 1p1AL. PEFP VA. O`A ITVP1 7C eAa Cm ME" 1[E RUM mraD•D Pb! AIKl101 attn ), FI►F MS PERS (1 KTO PER MAci-QI m I ION FOUADA11,11h DEIAL-, ''.r::^:. -Tym M1F •.. SEE THIS 94EEr FOUNDATION DETAILS POLE ELCVATIOIt W FOR MIND A" COMSTNC[01 NEIGHBORHOOD STREET STD, PLAN- 116.1 PUBLIC WORKS PEDESTRIAN LUMINAIRE fiPPRO A: DEPARTMENT FIXTURE AND POLE DETAILS t,�L k-1 INSTALL 1)FfAL;3'LTNBI=RS VERTICALLY. INSTALL IN DRY WEATHER, SO' F OR ABOVE. r- U x z c f FUR S1'Dl1J111117.1 I NUMBERLNG EXAMPLO 7 CI 7 6 7 PC@ $TDKM I1ILI.I17.2,117A 4.68` - 2_ 1 [*.CAL RFJTELiORLMD GOTiDC COLD OR WILETE LNiE.NDON BL," BAF KCiR04NI) 2 1-IGHT STANDARD PUBLIC WORKS DFCAI_ yUMBFR'NG SYSTEM a DEPARTME!OT F LED TYPE WATTAGE I�SID. PLAN- 121 ApFRE7V T ��� j PORTION OF THE NW 1 /4 OF THE NW 1 /4 SECTION 3, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. CITY OF R EN TON, STATE OF WASH I N GTON STREET LIGHTING CONTACTOR CABINET WIRING SCHEMATIC TYPE III SERVICE 120Z24Q VQ_1 1DO A MAW BREAKER (WIN.) 2 POLE 240 VOLT v v O IMP BRANCH BREAKERS Ld 120/2s0 VOLTFF iAlITCH--� TEST 16 POLE r CIRCUIT WRES TO LIGHTING RuNS 1 PHOTO -CELL TO GROUND MOUNTED ON ROD NEAREST LWMTNAI7E WIRING COLOR CODE. A. WHITE JACKET (NEUTRAL) B- BLACK JACKET (LINE) C. GREEN JACKET (GROUND) D. RED JACKET (LOAD) E. GREEN OR BARE VARE (GROUND) PUBEZC ►VOPJO I STREET LIGHTING CONTACTOR r DEPART1dENT CABINET SCHEMATIC HEAD MCINQ OP TIC MODAE TINST-LOCK OPENING SYSTEM 3AIRE4 MODULE CONSTRUCTION NOTES 1. ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO 81, MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION NS CHANGED ( I E- JUNCTION BOXES, LUMINAIRIF POLES, TRAFFIC SIGNAL POLES, SIGN POSTS) 2 ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL GRACE: ONCE CONSTRUCTION IS COO PLETE 3 ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION !.:NITS SHALL MEET CURRENT ADA STANDARDS I LE JUNCTION BOXES SHALL HAVE NON-SKID L:05 ] PLAN _ 123 TRANSPORTATION NOTES PUBLIC WORKS r �I DRPARTMENT A LUMINAIRES COMPONENTS htAo VIJ". , 1it7VR1 511APL A ICAVY 5PIAN ALLAi vW H000. STR AN ALUMINUM GECORADVE CUPOLA AND CAST ,ALUWW FINAL. TOPS AN ILECTIpa-1iBDED CLEAR ACRYLIC %K0 (MAR) ]E%U- UY PmYOR RLWANT THE VTWL IS MED14"CALLY AVA MBLED *ITM AN ALIANIIIM DE -CAST RING OL THE lOC 04 SYSTEM OPENr1'C ST5IEV. A DUAWER-AM4) LOCKING MECHAI'ISW 1NFH CON95FENT PRESSURE P*%rS ALLDRS A IGM-FREE ACLE55 MNSIOE tEE LUMONAOiE- 1D ME LIDS AND DRYER MADE *TH CAST ALVWNVM PARTS AM SEALED WTH A CASKET C01MSS ICA SYSTEM THE UJMN AQE OFFERS AN MPH IIEATHEPR00F PMTECT*4 COW MODULE: P SPUN ALLIIMNULA BALLAST HLIUSNNG 61M STARIaSS SITE1 CAPTIVE RE1NNPrC IAICKS W"FCATIDMM, NINNINANCE AND LIIMNAI K CmIrICA"QN SKNUIS ARE LOCATED 04 THE CONS LIFTER ACDIAE: CAST ALUlIt 7M ALLOY 356 FITTER COWPLETE NHTH FOUR (4) ARMS AND W 1UORATIA W. SECURED ON POLE Ntl J SET 5CIEC15 5/16-15 up6c SLIP -FITS DIN A N' OD Br S' LONG TENON OPTICALIELECTRICAL COMPONENTS LED BOARD: OATTADE PER PLACES 40DW (W40E), SJPER HIGH rluA OUTPUI AND HIGH L1AENiANCTk DESIOM FOR 4GH DOMT OPERATION FAST TCDL-FREE MAINIENANCT [HAT ALLOWS DOGV40UAL REPLACEMENT OF A DEITCfiF LED BY PVLLW. OUT THE PRCPER LAOT OPTIC TES TYPE 11 ILL]• 14 (x)• V (5L} IMF OPTIC'S REFLECTDR !S MADE OF PIE-ANCIDI'ED ALUM ILY REFLECTING'31EE7S (WX III% REFLECTION). SECLIENIED IN VULTAI FACETS AND WNTRAIM BY WATIPLE PERFICRATI M AND 10 FEAT SMIM RADIATOR 10 KEEP THE LAWS TEWPERATIIRE 000 AND RICREASE THEM LUNGEVITV AE ORFEILTATEOh OF EACH FACET "AS BEEN AETICIAAuSIY CALcuuoED :0 OPTlmn T+E LIGKI DISTFATLUT:ON FOR EACH wptgATIOII DRIVER N=4E WIH Db*R PRIMARY VOLTAGE 120 TO 277 NUTS SO Hi ASSEMBLED ON A 100L-fREE REOVASIX SIAMISS STEEL TRAY *IN +7"-DISCTXIEOT O"ECIDOS HIQH PONFli FACIOR OF wx MINI" STARTMNO WURMATUK -+Of GENERALIOPTIONS fmc/mmDLUFLT: IVE t[w 14-Z Ir MmMuM ExmEDMKC FROM LuN*JM ALL ELECTRICAL CONFECTIONS EIEITKEII MODULES AR{ MADE IV TH OuIGE-DISCONNECT WINECTORS ALL EVMD HARORARE r5 vAnI,ESS STEEL EPOM AND/OR SILICON GASn7hC ARE APPLEO COLOR RAL40 rl (XT ♦jEAC K) rII511: TEKTURED APPLICATIM Or A P01►ESTER POW COAT OF PAFNT [5 MILS/121 M)KTtONS} TK FINISH YEE1S THE ASIV G7, oil? AND 016M IKOIIREYFILTS RELAW9 10 SAKI SPRAY AVID NLHC4P[ATr K9SFAHCE NEIGHBORHOOD STREET '•PTA• :'LAN - 116.2 + + I'LJ DEPARTMENT PEDESTRIAN LUMINAIRE FIXTURE A ROVED: PA1�Fi1T t DETAILS LUNMWK T/KS YIJ. K A COMUMAOIS iy1 r1m nm RaDfT to nATUt wm MD TLIUS QGIJ10 am ry% PUTS WCf OppaP[CT TO LLN■MAm 3 "we; LAPUIm LIMMI1MPUMES PR.L K 1O SEC aLINE1r EQUAL AMC A A yLpKt[yC REJEK FO 111=1 IOCKM LID SIAMAm PI Fly IT AMNCTIO+ IQI tVKS I • MEWRAOA0AtWO lUE ITANIDAFPU PLAN rw10-W O10LA0 we Y1MWY ORAw ••Olt yl r w CAOMIT y%cwA SASE — TOP or CONCKRE F0.MOAROM m DFLEVEL KITH TOP OFS@'MALK DA Tvu 4• CON: MTQ PAO - I tir ' I• AMM M IML arm 4111IL1111111 am t -M EaARPKM r CVTOLAr FROM f�Metl C *mn sr1'ZT T - U04PAC SYSIOI ILLS TD COYTAC WILLS CWICD AS K[K0) CV1f.MKK r 14 a CIA sn•r• -- cDIAIMnM aao JIM NOTES. I EQUIPMENT GROUND ORE A DARE WIRE ANALL BE SECURELY FASTENED TO THE GROUND LUG 04SIDE THE POLE HANDMOLE All BONDING A GROUII CONNECTIONS SHALL REMAIN ACCES98LE FOR INSPECTruh AND MAINTENANCE I 2 IF THE FIKILRIE MANUFACTURER HAS MADE PROVISION FOR THE AIIACHMENI OF A GROUND ORE A GREEN INSULATED WIRE OF THE SAME SIZE SHALL BE RUN FROM THE FIXTURE TO THE GROUND LUG INSIDE THE POLE HANOHOLE- IF THE FIXTURE MANUFACTURER HAS A GROUND IIJG IPISULATEO WIRE SHALL BE RUN FROM THE FIXillpl GROUNO LUG TO T"r I'^• r GROAIN^ r OylhPUNUC - 136 WORKS TYPICAL LIGHTING DEPARTMFNT UNDERGROUND SYSTEM _ - W Il �>!T>D. PI AN - 119 O . STREET LICHT POLE + PLAN VIEW UUNCnON BOX 4" DEEP �•Y A J i IGHiING STANDARD & JUNCTION BoxA PLAN--VIEWAN-_VIEW INDIVIDUAL JUNCTION BOX LABEL THE SERFET FACING SIDE or THE wDNTACTOR CABW MYTH IT$ AORFSS NUMDI {YI SrREE7 NAALE)us" AN fmCRJINfD PHENDLIC pUNEPLAtf 1A4TH 2 K4H BLACK LETTFMK ON MIHITL EACKICNOUND ATTACH NAIIEPtAlf WITH ADHESIVE . 01 i I LIETERIWA . DILA 422 1i6 AWG �S NawG >r IE3T BvIPA4S INTERNAL PHC7#OCI.LL jIJ r tTFSCDIVFIiC T ' BREAIKER"y j r1r i� A �• - • - - " - - - y � I S lw Ct�l'flilLilS AUIU PABLOCKAISLE C1 30/2 CPA* LIIr,14 T£ST 1"IN RATCD 2¢ r-. RL'CFPVAFCL.0 ow r L � i. f S3 i'U .-•r'ti NLLVWN+lATION C I IP Mal PC, �ANII�AIYT 4.0 e�- a ti1AlAI iD �� 5 MJO SAG-_htih NS NECT - + 1 LOCAL ILI t)S rmr �I�TNE% XI LEFT SIDE FRONT VIEW 13 WIREH r r 1 BASE PLAN p NOTE' LOAD CURRI.HT FOR ALL BREAKER N07 TO EXCEED 80% OF. BREAKER AMPERAGE [NLL05LIRE CONSTRUCTION NOTES A iPCMItlR AJN 4:-INHt-v Ohl. �• wA. .M Q { ':1- -'1' ELL.CFMICiLLf 1Kl17.f1 ATAO AlM'OIf[G r'FAERL 14DI.1MTQ KQL : fiiM %Ty1AAC'NDR YPr,I ♦X FEiK ]11, PIyYMKiN1 A NL -Ain 401S molt %Knob L NIwA x SFNWAITII MilkM(FLLCTORIIi[1 G07 Pf GCLO 0w del 4 PARa, IRA }: ! MY-" 1PKL I60t Zr APKAIAE 1110M OUT W OF I MCI WWW LECETD ON jK m r■ tw I.rPi j mci f PMIY[RAF13 WILL Mr 00WAWTS IS OrdK KDP IN Cb1r1M'BL Wft c LIAR N w mw Al IOPI+ "SAL Rr PLWONLI r1 PrMf YYM+Y MH: F A PL#PIC CQJ wD ummo ' [MOR11L1 mu 1K ATrACwO m PHO I S61 or lot lPQK Dow irww of TAMM 1k 1At IY1Rr WWO 00 N"C/IY 10 R[OLMN NINA mw M to" f}TMITOARat 11 ■V MZF ARCH' VAMRKA 7'94 N OTE: CLASS 'S' CONCRETE To Be USED IN CONSTRUCTION OF PAD PUBLIC WORKS CONCRETE PAD [DETAILS Dye IIEPART!~ EM T-403203 IN COMPLIANCE WITH CITY OF RENTON STANDARDS ASBUILTS Pacific Ent., ih �y11� r °E w SURVEYED: SCALE,NOTED VERTICAL AID 1 83/1 CHRISTELLE RIDGE �� HORIZONTAL: NAD 1983/1991 CITY 0 F 3-22-2018 J. HOPPER SOUND BLDG & DEVELOPMENT, LLC Fl°°B0°'r' R E N TO N PAGE, 02 REVISION AS PER CITY COMMENTS ON 09/05/18 PJP 9/12/18 JH °�W"' P. PATEL 21222 132 N D AVE SE DRANNG NO: ONE INCH DATUM �I Civil Fn it �= 1 REVISION AS PER CITY COMMENTS ON 06/18/18 PJP 8/01/18 JH CHECKED: AT FULL SCALE Planning/Building/Public, Works De t. KENT WA 98042 r �e��1r� J s J. HOPPERP H 2 3 �€ Planning riQn,rJ�arJs ; IF NOT ONE INCH y A L �' 0� t4YUt NO. REVISION BY DATE APPR HOPPER SCALE ACCORDINGLY STREET LIGHT DETAILSJ. '' 23 �24 CONDUIT E NITH. AREA PLAN-M WE TO nT CA$INE T ' 6" ' � E hl _ d. � C�'rR7.3�i..7.L Sheri to r-kuinh bo Se■ Hole 3 4i s #4 hoops f—%'4 bw a44h corgi. IF 6' J J4 ULI%iSf8■ I' to 2' —j dlaFnatar plastic mein SIDE vjttj�l I. -A• Cahinat dopth 1.--4. ll � 2 is r- 'or -1141 e ■ y 1 !II PAD UOUNT QQNTROLLER CA)LIK T weu pAnui For NOTES see Std. Plan 126.2 *Aoft # PIJBLIC WORKS DEPARTMENT 14 twu ■ad C"W SIZE TO F7T CABLIRET — A{`rmk LAval Shim to plumb see Hale J +I JA heaps r f4 her aQtlr cofoln 6' MIN Q:"$ttr plastic dram g M f'� Val Cab nat depth +x 1a PIM—M ! PAID FOUNT 04 bar each It co"r CABINET FOUNDATIONDETAILSI f M.- PLAN ~ NOTE.• EXISTING UTILITY LOCATIONS SHOWS HEREON ARE APPROXIMATE ONLY IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. CALL BEFORE YOU DIG. 1-800-424-5555 PORTION OF THE NW 1 /4 OF THE NW 1 /4 SECTION 3, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. CITY OF R EN TON, STATE OF WASH I N GTON — II II 7dw.e A� p1A/IFee S!e Jan l! 3 9L111 In plwa� --. ■ eleipe See Now 3 -+= ` rL I■ to r J i � r KA Ila Aharnsly pqat+c wain (ana pr cwllool 3/6' dtrnat4• plawe,e drae+ io�a pw cobibiet) Sao Hele 1 Ilb' d I-grle p oe' r d -sr Saw I45Ie S ii I — ?o fE1 + ittnaad Irwndaloon pA * lorotdr ..Yew a "Pia . A:ar�evuct ma lop al anth eldewi grade. arnittie4 A:karnler Verse tap ens elaeadk OUL Viol lap 046 be 111ROK&O try a cow and eeyetrdctr ei t1n1d meat *4 rov.*0 tol a'I eet1-win 8-'• ■ 3 n the tIISDCr Standard SPWAkatlawa 2 P'ad woo l derma is tlpicdl. 3 ►Mitt • 6111110vor ad between 1++1 torwrellon W4 Cabal 4 AnOW rbdla ari Um* Woc%q to be uaWler by cabinet enenuleewrr and atobnalltM 1s, tht ingrllw ow 4WD%* S Canli IM the contreler and cwetaclr enb9eta tM+ap be rnehoilnl par She ceentmo; dins. ttutr orw 3' ware rapped out past the taamdatla+ 5 C*Avete all be C7bn 3M Win $a pewnn 7 7' CaM00 moll be pAeeed OFarn tl►! tw+toe4r to the on.rMana cont6o14,18as cabinet - 5ee +titela 3 d [eGr eatAelit filch naw ! 4' 4WRiotar 3+Selk vfne+ pq Leval ca a ll CdnMpor w.1nn 1l­! caobl ~ 1 D Itl+ael all NWW a41vilnet7 are to to di slaaad w4 1Pa.e4 Ptatl. � ■ curnbined 4rwdellan whom be sad 6 VAN - 3 • 14 1ldavlonow" liar (eqI.a fCccae) -- Sol Ia l S "f i I•t 0 0-..} t 1l l �f 11 � ti 3 - /4 Aa lwea+p ma jJ4 neaps, cawso tpartrtl MID ibJna� CC�y+r+bil ~ la Ado A v a1= � ey le s I ,i • _ej ONLY THE NOTES PF THIS STD DETAIL IS TO BE USED FOR STREET LIGHTING PURPOSE FOR NEW SERVICE CABINET KtPUBLIC WORKS DEPARTMENT ;ABINET FOUNDATION DETAILS i p r .. priio�7u COM81NED FOUNDATION 6 a.r.es F177W_j _51ka �qjjrj�_ —'.—o­eMjffi_ Mon i r%1A►ACTC0 — 7 )0" 4- 7/8" Ili - LOAD1 % FUSE curnNc r.PP"I. FUS KIT `i INLINE w UCE r- r^. r1% v v P r f I VIITL nt-LIk t_ LINE , 1A" 'F� ICE KIT ASBUILTS Pacx c EnyJ.rj��Y11�_ °E w SURVEYED: NOTED IZONITAL NAVDAIDI 88 CHRISTELLE RIDGE �� HORIzoNTAL NAD l/loci ' CITY 0 F 3-22-2018 Z DESIGNED:J. HOPPER SOUND BLDG & DEVELOPMENT, LLC Fl°°B0°'L' Des. Jfj1 R E N TO N i�� J� `� -0 02 REVISION AS PER CITY COMMENTS ON 09/05/18 PJP 9/12/18 JH °mow"' P. PATEL 21222 132 N D AVE SE DRAMIING No: ONE INCH DATUM ri �� lvi� �Je"! it �= 1 REVISION AS PER CITY COMMENTS ON 06/18/18 PJP 8/01/18 JH CHECKED: AT FULL SCAIE Plannin . Buildin Public Works Dept. KENT WA 98042 r y �eetin J -- s J. HOPPER 9/9� P 24 �€ PlanningriQn,rJ�arls ; IF NOT ONE INCH ` A L �' 0� t4YUt NO. REVISION BY DATE APPR A�0" D J. HOPPER SCALE ACCORDINGLY STREET LIGHT DETAILS '' 24 "24 /5" FUSE KIT & SPLICE KIT DETAllS 6Y o ADOPTED i4CITY ar ri NTDN ; STANDARD PLANE; LST DAM:04/04 [)W2 NA kAF• .101 3 qP PAnZ: - .IC11 1 T-403204 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CONS TRUC RON NO TES: 1. INSTALL NEIGHBORHOOD STREET PEDESTRIAN LUMINAIRE FIXTURE AND POLE PER STANDARD PLAN 116.1. CONCRETE FOUNDA TION AND ASSOCIA TED JUNCTION BOX PER STD DETAIL AND LUMINAIRE POLE SCHEDULE. 2. INSTALL ELECTRICAL SERVICE CABINET # XXX PER DETAILS COORDINATE WITH C.O.R. ERIC CUTSHALL, TRANSPORTATION OPERATIONS MAINTENANCE MANAGER 425-430-7423 FOR SERVICE INSPECTION. CONNECTION TO BE MADE BY THE CONTRACTOR AFTER INSPECTION. LABEL STREET FACING SIDE OF CONTACTOR CABINET WITH ADDRESS LOCATION FOLLOWING COR STD PLAN 122.1. J. INSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD FOLLOWING COR STD PLAN 120. 4. STREET LIGHTING SUBMITTALS SHALL BE SENT TO CITY FOR REVIEW AND APPROVAL PRIOR TO ANY PURCHASE OR INSTALLATION. 5. ELECTRICAL CONTRACTOR TO CONTACT CITY CONSTRUCTION INSPECTOR FOR INSPECTION OF POLE FOUNDATIONS, BASE BOLTS, AND CABINET FOUNDATION. 6. CONTRACTOR TO CONTACT TRANSPORTATION MAINTENANCE MANAGER FOR STREET LIGHTING COMPLIANCE TO STANDARDS INSPECTION. 7. FOLLOWING THE TRANSPORTATION MAINTENANCE INSPECTION, THE CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR SERVICE INSPECTION. 8. FOLLOWING THE SERVICE INSPECTION FROM CITY ELECTRICAL INSPECTOR, ELECTRICAL CONTRACTOR SHOULD SUBMIT APPLICATION TO PSE TO ENERGIZE THE STREETLIGHTING. 9. ELECTRICAL CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR FINAL INSPECTION AFTER STREET LIGHTING HAS BEEN ENERGIZED.