Loading...
HomeMy WebLinkAboutMFP22001805.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP22001805 IVR Number: 22001805 Permit Information Permit Name: ExteNet Systems - Fiber - SOUTH RENTON - PHASE 2 - SEG 17 S-007400 P-023587 - DIG AND REPAIRAddress/Location:04/08/2022Application Date:3623049001Parcel Number: 616 SW 41ST ST Permit Type:06/02/2022Issue Date:Franchise Permit Work Class:06/02/2023Expiration Date:Minor Utility Job Number: S RENTON - PH 2 - SEG 17 S-007400 P-023587 dig&repFranchise Type:Telephone Description: ExteNet Systems Inc. master franchise agreement, ORD 6013 SOUTH RENTON PHASE 2 SEG 17 S 007400 P 023587 DIG AND REPAIR DIG AND REPAIR EXISTING CTL/LUMEN 4" CONDUIT ON THE EAST SIDE OF LIND AVE SW, FROM THE SOUTH EAST CORNER OF SW 27TH ST AND LIND AVE SW, SOUTH . PULL (3) 1.25" INNERDUCTS WITH (1) 864F CABLE THROUGH. RESTORATION PER CITY OF RENTON STANDARDS. Contacts Name Address PhoneTypeBilling MGC Permits MGC Technical 6244 185th AVE NE, STE 250 REDMOND, WA 98052 ApplicantX Rachel Fenton Extenet Systems LLC 3030 Warrenville Road Warrenville Rd, Suite 340 Lisle, IL 60532 Applicant Michael Smith Dycom Industries dba North Sky 11818 SE Mill Plain Blvd, SUITE 410 Vancouver, WA 98684 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 BOSS CONSTRUCTION SERVICES dba Utiligi Communications LLC 111 Nyberg Rd SW Pacific, WA 98047 B: (253) 863-3881Contractor Business License Number: 50846Construction Contractor: UTILIL*808CO C/O PROLOGIS - RE TAX 1800 WAZEE ST DENVER , CO 80202 Owner General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF PUBLIC WORKS Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 1 of 2 | Published: 11/25/2019 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN (TCP) APPLICATION Published: 11/25/2019 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. TO THE APPLICANT: Submit the TCP application form and required submittal documents to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address. The following items, electronic copies preferred, are all required for submittal of the TCP Application: 1.☐ A copy of the Traffic Control Plan (TCP) Application form. 2.☐ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall: ☐Include map(s) showing the location of the project and work area. ☐Be legible lettering and clear, contrasting, symbols of viewing or printing. ☐Must indicate street names, and north arrow and scale. ☐All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. ☐Types of plans required: ☐Work hour plan – show all mobility impacts during construction hours. ☐Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. ☐Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. ☐Pedestrian access/detour plan, if applicable. Project Name: ______________________________________________ Permit #: _____________________ Project Address: ____________________________________________________________________________ Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Description of Work, Work Schedule, Equipment Used: _____________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ Construction Company: ________________________________________ Phone/Cell: (_____) _____-________ Applicant Name: _________________________________ Email: ______________________________________ Business Address: _________________________________ City/State: __________________ Zip: __________ Approved By: _______________________________________________ Date: ________________________ Transportation Operations Engineering EXTENET SOUTH RENTON - PHASE 2 - SEG 17 S-007400 P-023587 - DIG AND REPAIR 616 SW 41ST ST 04/11/22 04/13/22 9am 3:30pm PULL (1)144F CABLE THROUGH EXISTING CTL CONDUIT ON LIND AVE SW, DIG AND REPAIR A PORTION OF CONDUIT UTILIGI COMMUNICATIONS 253 548 5936 RICK POWERS RICK.POWERS@UTILIGI.COM 111 NYBERG RD SW PACIFIC, WA 98047 MFP22001805 Monday - Friday Scott Warlick CED 6/2/2022 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 2 | Published: 11/25/2019 APPLICANT AGREES TO ALL THE FOLLOWING: •TCP must be approved prior to commencing the work, and all permit conditions shall be met. •Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. •Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. •The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of traffic. This includes set up within the traveled way or immediately adjacent to the roadway. •Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures. •Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure. •TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT) and all traffic regulations of the City of Renton and Revised Code of Washington (RCW). •Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State and City codes. •Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Applicant’s agents and employees. •The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. •In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay for legal counsel chosen by the City to defend against same. •Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. •Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. •Approved Temporary TCP must be at the work site during work hours. •Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. •Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: •Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. •Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. •The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site. •Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street; 425-430-7423). _______________________________ _______________________________ _______________________ Applicant’s Signature Print Name Date Daniel Mendoza 04/01/2022 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 2 - SEG 17NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 616 SW 41ST ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 17 - DIG AND REPAIR - TCPS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 13Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE (FOR URBAN ARTERIAL ROADWAY'S)TRAFFIC CONTROL PLAN #1 - USE SET-UP WHERE APPLICABLE ALONG LIND AVE SW (NORTH BOUND LANE)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITY2700 LIND AVE SWPARCEL NO.12538001202423 LIND AVE SWPARCEL NO.3023059086W20-1W20-5RW4-2RXXXL2' MINWORK AREA 10'X10'WORKVEHICLEW20-1LIND AVE SWSW 27TH ST W20-1W20-1MFP22001805 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 2 - SEG 17NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 616 SW 41ST ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 17 - DIG AND REPAIR - TCPS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 23Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE (FOR URBAN ARTERIAL ROADWAY'S)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYTRAFFIC CONTROL PLAN #2 - USE SET-UP WHERE APPLICABLE ALONG LIND AVE SW (NORTH BOUND LANE)LIND AVE SWXL2' MINWORK AREA 10'X24'WORKVEHICLEW20-1W20-5RW4-2RXXW20-150'-100'2700 LIND AVE SWPARCEL NO.1253800120PARCEL NO.1253810090MFP22001805 NO.123PROJECT NAME: EXTENET TUKWILA - PHASE 2 - SEG 17NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 616 SW 41ST ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 17 - DIG AND REPAIR - TCPS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 33Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE (FOR URBAN ARTERIAL ROADWAY'S)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYTRAFFIC CONTROL PLAN #3 - USE SET-UP WHERE APPLICABLE ALONG LIND AVE SW (NORTH BOUND LANE)LIND AVE SW2700 LIND AVE SWPARCEL NO.12538001202900 LIND AVE SWPARCEL NO.1253790010SW 29TH ST XL2' MINWORK AREA 10'X10'WORKVEHICLE W20-1W20-5RW4-2RXXW20-1W20-1MFP22001805 NO.123PROJECT NAME: PHASE 2 - SEG 17 S-007400 P-023587 - DIG AND REPAIRNORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 616 SW 41ST ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 17 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RSITE LOCATIONSHEET INDEXSCOPE OF WORK:DIG AND REPAIR EXISTING CTL/LUMEN 4"CONDUIT ON THE EAST SIDE OF LIND AVE SW,FROM THE SOUTH EAST CORNER OF SW 27THST AND LIND AVE SW, SOUTH . PULL (3) 1.25"INNERDUCTS WITH (1) 864F CABLE THROUGH.Know what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 19ADDRESS: 616 SW 41ST ST, RENTON, WA 98057PROJECT NAME: SOUTH RENTON - PHASE 2 - SEG 17 S-007400 P-023587 - DIG AND REPAIR - PLANS1. COVER SHEET / SITE LOCATION2. LEGEND3. GENERAL NOTES4-6. DESIGN VIEWS A-C7. UNDERGROUND DETAILS8. SITE PHOTOGRAPHS9. BUTTERFLY DIAGRAMSSHEET 4SHEET 5SHEET 6CONTACTSMATT FRASERMGC TECHNICAL CONSULTING, INC.6244 185TH AVE NEREDMOND, WA 98052C.206.618.5254MATT@MGCTECHNICAL.COMNORTH SKY COMMUNICATIONS,LCC CONTACT:MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C.206.305.5881MSMITH@NORTHSKYCOMM.COMMFP22001805 NO.123PROJECT NAME: PHASE 2 - SEG 17 S-007400 P-023587 - DIG AND REPAIRNORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 616 SW 41ST ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 17 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 29#F#F#F##LEGENDMFP22001805 NO.123PROJECT NAME: PHASE 2 - SEG 17 S-007400 P-023587 - DIG AND REPAIRNORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 616 SW 41ST ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 17 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RGENERAL NOTESKnow what'sbelow.before you dig.CallRGENERAL NOTES:UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTINGAND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTINGTHE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES. THEDISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED.TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURING CONSTRUCTION, TO ASSURE THAT THE WORK ISFOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALLOTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THECONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY.SPECIFICALLY STATED OTHERWISE.CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCHALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE CITY OF RENTON ENGINEERINGALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS, EARTHCONFIDENTIAL/PROPRIETARYSHEET: OF 39The locations of utilities shown on these drawing are only approximate. MGC TECHNICAL CONSULTING, INC. hereby disclaims any responsibilityto third parties for the accuracy of this information. Persons working in the area covered by this drawing must contact the statewideCall-Before-You-Dig System to ascertain the location of underground utilities prior to performing any excavation.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEED SITE WORKSTANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE CITY OF RENTON REGULATIONS AND APPLICABLE STATEAND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLESTANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIREINSPECTED AND APPROVED BY THE CITY OF RENTON INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TOBE PROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES, AS SHOWN ONTHESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THEFIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCALUTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTSUTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.CONTRACTOR SHALL NOTIFY THE CITY OF RENTON INSPECTOR AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTHTHE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE CITY OF RENTON AND ALL UTILITY COMPANIES WITH REGARDACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLETHE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDSTIMES.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO: EXCAVATION,TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HIS SUBCONTRACTORS, ORALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESSFOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE CITY OF RENTON, THE CONTRACTOR SHALL SUBMIT ATRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIESWITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFICCONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BEHELD WITH CITY OF RENTON.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THEINTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVEDOR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALLCONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT ATTHE CONSTRUCTION SITE AND AVAILABLE TO THE CITY OF RENTON INSPECTOR AT ALL TIMES.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATIONALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TOTIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING.DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THETIME PERIOD APPROVED BY THE CITY OF RENTON.1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16.MFP22001805 NO.123PROJECT NAME: PHASE 2 - SEG 17 S-007400 P-023587 - DIG AND REPAIRNORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 616 SW 41ST ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 17 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 49MATCH TO SHEET 5DESIGN VIEW A Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #8 FOR SITE PHOTOGRAPHS.LIND AVE SWSW 27TH ST82'16'59'7'12'11'12'11'13'29'21'57'15'11'11'12'11'12'2700 LIND AVE SWPARCEL NO.12538001202423 LIND AVE SWPARCEL NO.302305908692'CONSTRUCTION NOTES1EXISTING CTL/LUMEN VAULT. ACCESS VAULT TO PULL (1)864F CABLE THROUGH. CONTRACTOR TO VERIFY CORRECTVAULT PRIOR TO WORK.2EXISTING CTL/LUMEN 4" CONDUIT, . PULL (3) 1.25"INNERDUCTS WITH (1) 864F CABLE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.12150'1MH 369MATCH TO EXTENET SOUTH RENTON - PHASE 2 - SEG 13 - CTL PLANS CTL/LUMEN NOTE1.SEE SHEET 9 FOR BUTTERFLY DIAGRAMS.MFP22001805 NO.123PROJECT NAME: PHASE 2 - SEG 17 S-007400 P-023587 - DIG AND REPAIRNORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 616 SW 41ST ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 17 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 59CONSTRUCTION NOTESMATCH TO SHEET 4 MATCH TO SHEET 6DESIGN VIEW B Know what'sbelow.before you dig.CallRRESTORATION NOTESARESTORE LANDSCAPE PER CITY OF RENTONSTANDARDS.GRESTORE SIDEWALK PANEL PER CITY OFRENTON STANDARDS.LIND AVE SW2700 LIND AVE SWPARCEL NO.1253800120PARCEL NO.125381009081'19'56'6'11'11'18'11'22EXISTING CTL/LUMEN 4" CONDUIT, . PULL (3) 1.25"INNERDUCTS WITH (1) 864F CABLE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.3PROPOSED DIG AND REPAIR EXISTING CTL/LUMEN 4"CONDUIT, . PULL (3) 1.25" INNERDUCTS WITH (1) 864FCABLE THROUGH. CONTRACTOR TO VERIFY CORRECTCONDUIT PRIOR TO WORK.115'235'22'32AG12'39'All new conduit in the ROW shall be schedule 80 or equivalent.MFP22001805 NO.123PROJECT NAME: PHASE 2 - SEG 17 S-007400 P-023587 - DIG AND REPAIRNORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 616 SW 41ST ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 17 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 69CONSTRUCTION NOTESMATCH TO SHEET 5DESIGN VIEW C Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #8 FOR SITE PHOTOGRAPHS.LIND AVE SW2700 LIND AVE SWPARCEL NO.1253800120PARCEL NO.125381009081'27'44'10'11'11'11'11'61'11'45'5'22'2900 LIND AVE SWPARCEL NO.1253790010SW 29TH ST239'122CTL/LUMEN NOTE1.SEE SHEET 9 FOR BUTTERFLY DIAGRAMS.MH 3691EXISTING CTL/LUMEN VAULT. ACCESS VAULT TO PULL (1)864F CABLE THROUGH. CONTRACTOR TO VERIFY CORRECTVAULT PRIOR TO WORK.2EXISTING CTL/LUMEN 4" CONDUIT, . PULL (3) 1.25"INNERDUCTS WITH (1) 864F CABLE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.MATCH TO EXTENET SOUTH RENTON - PHASE 2 - SEG 12 - S-007400 P-023587 - CTL PLANS MFP22001805 NO.123PROJECT NAME: PHASE 2 - SEG 17 S-007400 P-023587 - DIG AND REPAIRNORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 616 SW 41ST ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 17 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 79UNDERGROUND TYPICALSTYPICAL TRENCH IN SOIL DETAILSCALE: NTSEXISTING GROUNDWARNING TAPEBACKFILL(8" LAYERS)6" MIN.12"36" MIN. DEPTH4"BACKFILL(COMPACTED @ 90%)HDPE DUCTCLEAN BACKFILLBACKFILL(COMPACTED EARTH @ 90%)6" MNRL AGG TYPE 2(COMPACTED AS SPECIFIEDIN CONTRACT DOCUMENTS)TYPICAL CONCRETE SIDEWALK PANEL CROSS SECTION DETAILSCALE: NTSNEW PANEL-MATCH EXISTINGEXPAND TO JOINTMATCH EXISTING24"12"6"6"6" MIN. TYPE 2 CRUSHEDROCKCOMPACTED BACKFILL6" SAND COVER6" SAND BEDDINGMFP22001805 NO.123PROJECT NAME: PHASE 2 - SEG 17 S-007400 P-023587 - DIG AND REPAIRNORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 616 SW 41ST ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 17 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RSITE PHOTOGRAPHSCONSTRUCTION NOTESKnow what'sbelow.before you dig.CallRPHOTO #1: FACING NORTH ON EAST SIDE OF LIND AVE SWPHOTO #2: FACING SOUTH ON EAST SIDE OF LIND AVE SWCONFIDENTIAL/PROPRIETARYSHEET: OF 8912211EXISTING CTL/LUMEN VAULT. ACCESS VAULT TO PULL (1)864F CABLE THROUGH. CONTRACTOR TO VERIFY CORRECTVAULT PRIOR TO WORK.2EXISTING CTL/LUMEN 4" CONDUIT, . PULL (3) 1.25"INNERDUCTS WITH (1) 864F CABLE THROUGH.CONTRACTOR TO VERIFY CORRECT CONDUIT PRIOR TOWORK.MFP22001805 NO.123PROJECT NAME: PHASE 2 - SEG 17 S-007400 P-023587 - DIG AND REPAIRNORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 616 SW 41ST ST RENTON, WA 98057DRAWING NAME: NORTH SKY COMMUNICATIONS - SOUTH RENTON - PHASE 2 - SEG 17 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 99BUTTERFLY VAULT DIAGRAM MH# 369 3 WAY 1.25ALL W/ FIBER1800X4" VAC3 WAY2 -1.25 I:D W/FIBER13/4 I:D VAC2200X4" VAC2200X200X1.25 I:D VAC2" W/100X4 WAY 1" I:DALL W/FIBERMATCH TO MH 370BUTTERFLY VAULT DIAGRAM MH# 370 MATCH TO MH 3694 WAY 1" I:DALL W/ FIBER100X4" VAC2700X4" VAC4" VAC4" VACTO PROPOSED DIG AND REPAIR4" VAC2200X3-WAY 1" I:D2 W/ FIBER1-VAC100X600X100X4" VACMATCH TO MH 371SOUTH RENTON - PHASE 2 - SEG 12S-007400 P-023587 - CTL PLANSMATCH TO MH 368SOUTH RENTON - PHASE 2 -SEG 13 - CTL PLANS3 WAY 1.25 I:D2 VAC W/FIBER4" VAC4" VACMFP22001805