Loading...
HomeMy WebLinkAboutEX02_Site_PlanScale : Update Date : Page Size : Site Contact Phone # Site Address : Drawing Number : Drawing Description : 1/8" = 1' Concept Drawing 1 of 1 Designer : 425.979.1933 GENERAL DRAWING NOTES: All measurements, heights, and dimensions given are subject to verification by installing contractor and property owner. Every attempt to insure the accuracy of this drawing has been made by Oquist Landscape Design. However, all parties should be aware that minor changes may be needed once construction begins for the proper completion of this design. No drawing created by Oquist Landscape Design should be considered binding plans or agreements between a contractor or property owner. Any and all permits required for the completion of this design are the responsibility of the property owner, and or licensed contractor(s). Update # Hirani Residence 24" x 36" 9 20'-0" 16'-0" 4'-0"2'-0"2'-0" 10'-0"6'-0" 1928Drawing #Issue Date :2/25/2021 11/11/2021 Site Contact Person : Property Owner # Property Owner : DRAWING NOTES: All Steps have 6" Risers Unless Otherwise Noted Some dimensions have been rounded to the nearest 6" for readability and estimating purposes. Artificial Turf Decorative Aggregate Planting Bed Creeping Red Fescue Block Retaining Wall Seat Wall (20" Sitting Height) Paver Patio Or Landing Existing Deck Existing Rock Retaining Wall Existing Asphalt Driveway Existing Concrete Step or Wall Light 20'-0" 6'-0"3'-0"4 ' - 0 " 8 ' - 0 " 11'-0" 4'-0" 9 ' - 0 " 12'-0" 4 ' - 0 " 4'-0" Prop. Line Prop. Line French Drain Seat Wall 20" WALL 1 : Up to 4'-0" WALL 2 : Up to 4'-0" WALL 3 : 1'-0" WALL 4 : 4'-0" WALL 5 : 4'-0" WALL 6 : Up to 4'-0" 4'-0" 12'-0" 1 2 ' - 0 " 4 ' - 0 " Existing Rockery to Remain as is Existing Rockery to Remain as is 1,830 sf 426 sf 1,077 sf 82 sf 0 sf 1,498 sf 52 sf 594 sf 1,682 sf 958 sf Drawing Notes: Square footage estimates are for materials inside property lines only. If any dimensions are in conflict with recent survey, survey is considered more accurate and will supersede this drawing. If any dimensions are in conflict with engineered drawing, engineered drawing is considered more accurate and will supersede this drawing. 2708 Williams Ave North Renton WA 98056 425.830.2387 Rick, Hirani 4 ' - 0 " 13'-6" A/C Unit EXHIBIT 2 Markup Legend RED Required Revisions BLUE Recommended Revisions PURPLE Advisory Only RECEIVED 02/24/2022 BGillia PLANNING DIVISION DocuSign Envelope ID: 39AA7884-9374-44CF-BC0D-81C1EAEEE31F