HomeMy WebLinkAboutKC-16-207 & KC-16-208 - 28-day break - SG Foundations - 04-07-16a 155 M171ire Avenue Nb. 1308. IJ,
Kenlnli_ WA 93UJ6-4199
rnmx: (2015) -,915-/ /U9
Concrete Compression Tesl Report Kiny County 1'.,n: (LUI)) L90 -UI /9
rplilliffiritilli-COMF11111551111111111111 10511 NP -rt
Project: City of Renton - Logan Ave N.
Guncrete Placed By: Amays EleL;triL;
uunurvty Supplier: milwo
Plant Location:
Placement Location:
Gunurete Use:
Sumner - 202
shafts
Slump: 71/4" Air Uuntent: 1.6%
Unit Wuiyht: 150.Opcf Temperature: 74°F
Aggregate Source(s): Cuarae: a-3za, Fine: B-3zv
Project Number:
Placumunt Inspactur:
Tests and Cylinders by:
Mix Design Number:
Pole Bases P-2 & 5-3
1126896
Shawn Shirty
Casey Wagner
04432F
StrenytH Spuuitivatiun: 4uuupsi at ZS aay8
Dcsiyn w/(c;+p)
Actual w/(c-rp)
0.44 Date uylinacrs oast:
w13 Time Cylinders Cast:
ASTM C39: Tesi Mezhod for Compressive Szrengzh of Cylindrical Concrete Specimens
4/7/16
13:51
Fracture
Type
Age at
Testing
(Days)
Lab Number
Date
Received
Date of
Test
Cylinder Dimensions
Total Load
(Lbs)
Unit Load
(psi)
Unit Load
(MPa)
Length
Diameter
Diameter(x)
Area
Type 2
7
KC -16-206
417116
4/14/16
7.98in
4.00in
4.02in
12.63in2
58,570
4640
32.0
Type 2
28
KC -16-207
4/7/16
5/5/16
8.00in
4.01 in
4.01 in
12.63in2
86,010
6810
47.0
Type 3
28
KC -16-208
4/7/16
5/5/16
7.99in
4.01 in
4.01 in 12.63in2
86,990
6890
47.5
History of Individual Compressive Strength Tests For This Project and Mix ID
Remarks: Reference: WSDOT Std. Specifications 6-02.3(4) & 6-01.3(5).
Field tests performed using ASTM C31/C31M, C138, 01437 C1 tz, C231, and C1064.
X meets
Material il t meet apove specifications.
a
Qistnbuhon By S N Submitted By 6W 5lsrm16
W. ona ngm- or Crate inmal Daw
Form: Fieltluoncrew iescReport riewsed:Biz dW
Second Most Recent
First Most Recent
Current Individual Strength
Running Average
Individual Strength Test
Individual Strength Test
Test
of the Three Most
Recent Individual
Strength Tests
Date of Test
5/3/2616
5/4/2016
5/5/2016
,Cylinder Strength 7056psi
I 7090psi
6120psi
I 6230psi
6810 si
6890psi
Average Strength 7070psi
6180psi
6850psi
6700 si
Remarks: Reference: WSDOT Std. Specifications 6-02.3(4) & 6-01.3(5).
Field tests performed using ASTM C31/C31M, C138, 01437 C1 tz, C231, and C1064.
X meets
Material il t meet apove specifications.
a
Qistnbuhon By S N Submitted By 6W 5lsrm16
W. ona ngm- or Crate inmal Daw
Form: Fieltluoncrew iescReport riewsed:Biz dW