HomeMy WebLinkAboutKC-16-260 & KC-16-261 - 28 day break - Driveway Ramps Sidewalk - 05-12-16L9 t �i moi,roz A.MOC ton, 131017. v.
Renton, WA 98056-4199
Phone: (206) 296-7709
Concrete Compression Test Report Icing Gvunty r -ax: (206):!96-0179
conauto comprossiun Test Report
Project:
City of Renion - Logan Ave N.
Project Number:
1126896
c;uncrutEi Placed By:
Highmairk Concrete
Placement Inspector:
Shawn Shirey
t✓un ,urctc Supplier:
miles
I gists and Cylinders by:
Casey Wagner
Plant Location:
Pacific - 203
Mix Dti5iyn Number:
0442A
Placement Location:
Sidewallk, Ramps & Driveway
Q 3rd and Logan Ave
28
Uuncrete Use:
Sidewalk & Driveway Strength Specification: 4000psi at 28 days
blump: 51/2"
Air Guntent: 5.0% Desiyn w/(c+p)
uxz! Date Gyllnders Gast:
5/1z116
Unit Weight: 143.8pcf
Ttvmperatulc: 733F Actual w7(c+p)
0.42 Time Cylinders Gast:
11:1v
Aggregate Source(s):
Coarse: B-3zv, Fine: B-3zv
6/9/16 8.02in
4.01 in
ASTM C39: Test Methoo for Compressive StrungtR Ur cylinariodl concrCty SpCcimens
Fracture
T e
YP
Age at
Testing
(Days)
Lab Number
Date
Received
Date of Cylinder Dimensions
Test
Length Diameter Diameter(x) Area
Total Load
Lbs
( )
Unit Load
(psi)
Unit Load
(Mi3a)
Type 2
7
KC -16-259
a;13,1 ti
5/19/16 8.02in
4.00in
4.01 in 12.60in2
45,560
3620
25.0
Type 2
28
KC -16-260
5/13/16
6/9/16 8.00in
4.00in
4.02in 12.63in2
56,300
4460
30.8
Type 2
28
KC -16-261
5/13/16
6/9/16 8.02in
4.01 in
I 4.02in 12.66in2
58,150
4590
31.6
Hisiory of Individual Compressive Strength i cats Fur i Ris Prvicut ana Mix ID
Second Most Recent
First Most Recent
Current Individual Strength
Running Average
Individual Strength Test
Individual Strength Test
Test
of the Three Most
Recent Individual
Strength Tests
Date of Test 5/12/2016
6/8/2016
6/9/2016
,Cylinder Stren th 4770 si
4810psi
4290psi 1 4270psi
4460 si 4590 si
Avera a Stren th I 4790psi 1
4280psi
4530psi
i 4530psi
emar s: Reference: WSDO I Std. Specifications -
Field tests performed using ASTM C31/C31M. C138, C143, C172, C231, and C1064.
X meets
Material above specifications=
Atalls to meet
Appn^wea for
Distribution By:`r
Matenals Engineer Date
Tested and
Submitted By. Gw MMU16
Initial Date
/7C,
Form FieIC Concrete Test neport Rawsed. U21108