HomeMy WebLinkAboutKC-16-270 & KC-16-271 - 28 day break - Bus shelter & hydrant pads - 05-17-161» mulrrei! nv%htrC NG, Isldg. u.
RCI,101., WALIM J2SUlU-41 `lJ
1'1whC: (LU6) _,v6-/ /UJ
Curicictu ComprCaalt7n Teat Repria Kir Fax: (206) 296-0179
Concreie Compression Test Repen
Prujeet: City ut Rentun - Lugan Ave N.
Concrete Placed By: Highmark Concrete
Concrete Supplier: Miles
Plant Location:
Placement -Location:
Concrete Use:
Slump
Pacitic - 203
Prujcct NumScr.
Placement Inspector:
1126896
Shawn Shirev
Tests and Cylinders by: Casey Wagner
Mix Desiyn Number: 0442A
Bud Pad Bdae (w HuuaekeeNiny Pada at Hyardnta dna Lights
Slab/Pads Strength Specification: 4uuupsi at zu days
Air Content: 4.13% Design w/(c+p) u.44 Date Cylinders Cast: 5nH16
Unit Weiyht: ,44.upcf Temperature: WF Actoal w/((+p) u.4z Time Cylinders Cast: 10:56
Ryyrtvyate Suuruu(s): Coarse: B-329, Fine. B-329
ASTIVI c39: Test Method tur Compressive Strength of Cylindrical Concrete Specimens
Fracture
Type
Age at
Testing
(Days)
Lab Number
Date
Received
Date of
Test
Cylinder Dimensions
Total Load
(Lbs)
Unit Load
(psi)
Unit Load
(MPa)
Length
Diameter
Diameter x
Area
Tyee 2
7
KC -16-269
13 1b
5/18/16
5/24/16
8.00in
4.00in
4.02in
12.63in2
48,060
3810
26.3
Type 5
28
KC -16-276
6/14/16
8.02in
4.01 in
4.06in
12.60in2
61,756
4906
33.8
Type 2
28
KC -16-271
5/18/16 6/14/16
8.00in
4.01 in
4.01 in
12.63in2
61,190
4850 33.4
iE6-#6z''�2
History ut Individual compressive StrengtH Tests Fur TFis Prvject and Mix ID
Remarks: Reference: vvSDOT Std. Specifications 6-uz.3(4) & 6-02.3(5).
Field tests performed using ASTRI C31/C31M, C1313, C143, CI iz, CZ31, and C1064.
x meets
Mate�lal
above specifications.
s meet
Approved ;or
V
oisrn�ut on By (/J
M. c n.4-, ry rk�P.,Dete
Tes*d and
murnmetl By. 1018 C714MIG
Initial date
Form: Field Concrete Test Report Revised: 8/21/08
Second Most Recent
First Most Recent
Current Individual Strength
Running Average
Individual Strength Test
Individual Strength Test
Test
of the Three Most
Recent Individual
Strength Tests
Date of Test
6/14/2016
,Cylinder Strength
4900psi F4850psi
Avera a Strength
I
4880psi
Remarks: Reference: vvSDOT Std. Specifications 6-uz.3(4) & 6-02.3(5).
Field tests performed using ASTRI C31/C31M, C1313, C143, CI iz, CZ31, and C1064.
x meets
Mate�lal
above specifications.
s meet
Approved ;or
V
oisrn�ut on By (/J
M. c n.4-, ry rk�P.,Dete
Tes*d and
murnmetl By. 1018 C714MIG
Initial date
Form: Field Concrete Test Report Revised: 8/21/08