HomeMy WebLinkAboutKC-16-280 & KC-16-281 - 28 day break Subgrade Slab @ East Lanes - 5-18-16t L9 I)) Monroe Aveime NE, Bldg. D, Keiuuu_ WA 98056-4199 Concrete Compression Tesr Report King County t-.,.: (1,066) L96 -0i /9 cuncreto cumpression TCst Rcpun Prujcct: City of Renion - Logan Ave N. Concrete Placed By: Highmark Concrete Concrete Supplier: Miles Plant Locatiu� I: Sumner - 202 Project Number: 1126896 Placumunt Inspuutur: Shawn Sflirey I cats ana uylinac,, Dy: Casey Wagner Mix Design Number: 0442A Placement Location: Roadway Base Lift SlaF3 a South Bound Cogan Ave in East Lane -1 of 3 Concrete Use: Roadway Base Slab 5trenytn Speciticatiun: 4uuupsi at 28 days Slump: 4,/z" Air Guntent: 4.5% Dusiyn w/(L;+p) 0.43 Data uylindws Last: 5/18/16 Unit Weiyht: 144.5pcf I cmptnatlhu: 71°F Actual w/(c;+p) 0.43 Tme Cylinders Cast: 7:41 Ayyrcyate 5uurc;G(5): Coarse: B-329; Fine: B -3z9 AS i ISI WEI: Test Metfiva fur cumpressive Strength of Cylindrical Concreze Specimens Fracture Type Age at Testing (Days) Lab Number Date Received Date of Test Cylinder Dimensions Total Load (Lbs) Unit Load (psi) Unit Load (MPs) Len th Diameter Diameter x Area Type 5 2 KC -16-277 ,113/16 5/20/16 8.01 in 4.01 in 4.ulin 12.63in2 39,720 3150 21.7 Type 2 1 5 KC -16-278 5/19/16 5/23/16 1 8.01 in 4.00in 4.01 in 12.60in2 1 50,540 4010 1 27.6 Type 2 7 KC -16-279 5/19/16 5/25/16 8.00in 4.00in 4.02in 12.63in2 53,540 4240 29.2 Type 2 28 KC -16-280 5/19/16 6/15/16 8.00in 4.00in 4.02in 12.63in2 64,780 513e 35.4 Type 3 28 1 KC -16-281 5/19/16 6/15/16 8.00in 4.01 in 4.02in 12.66in2 65,710 1 5190 35.8 Ai5tury wf Inaividual Compressive Strength Tests For This Project and Mix ID Remarks: Reference: WSDOT Std. Specifications 6-02.3(4) & 6-02.3(5). Field tests performed using ASTM C31/C31 M, C138, C143, C172, C231, and C1064. X meets Material above specifications. f s o ee Approved for / 7estea and Dtstribat-on By l Submitted By. Low �laredais engineer ware Irdtiai Date Form. Field Concrete Test Rerort Remsed: a/zlR1a Second Most Recent First Most Recent Current Individual Strength Running Average Individual Strength Test Individual Strength Test Test of the Three Most Recent Individual S�,rength Tests Date of Test 6/9/2016 6/14/2016 6/15/2616 C linder Stren th 4460 si 4590 si 4906 si 4850 si 5130 si 5190 si Avera a Strength I 4530psi 4880psi 5160psi 4860psi Remarks: Reference: WSDOT Std. Specifications 6-02.3(4) & 6-02.3(5). Field tests performed using ASTM C31/C31 M, C138, C143, C172, C231, and C1064. X meets Material above specifications. f s o ee Approved for / 7estea and Dtstribat-on By l Submitted By. Low �laredais engineer ware Irdtiai Date Form. Field Concrete Test Rerort Remsed: a/zlR1a