HomeMy WebLinkAboutKC-16-292 & KC-16-293 - 28 day break Subgrade Slab @ East Lanes - 5-18-16I1..) M0 ... M: AVcjIUC IN E, 131UY. D. Renton, WA 980.)6-4 i 99 L9 Phone: (206) 296-7709 Concrere Compression Tesr Reporr King Gvunty r -ax: (206) 296-0179 Concrete compression TeST Repoli Project: City of Renzon - Logan Ave N. Concrete Placed By: Highmark Concrete uuncrcte Supplier: Miles Plant Location: Pattitl.; - 203 PruiCct Num6cr: 1126896 Placement Inspector: Shawn Shirey I ests and Cylinders 6y: Casey Wagner Mix Design Marn5vr: 0442A Placement Location: Roadway Base L;ft Slab @ South Bound Logan Ave in East Lane - 3 of 3 Concrete Use: Roadway Base Slab Suengih Specification: 4000psi at 28 days Slump: 4,/z" Air Content: 4.ir0 Design w/(c+p) u.43 Date Cylinders Cast: 5115nb Unit vveiynt: 144.7pef Temperature: 73`'F Actual w/(L;+p) u.41 I ime Lylinders Cast: Aggregate SuurcEi(s): Coarse: B-329; Fine: B-329 ASTM W9: Test IOIetRua Tor uumpressive StrengtR ut uylindrival uunurete Spuuimens 1u:Ii Fracture Type Yp Age at Testing (Days) Lab Number Date Received Date of Test Cylinder Dimensions Total Load Lbs (Lbs) Unit Load (psi) Unit Load (MPa) Length Diameter Diameter x Area Type 2 2 KC -16-289 5,19/16 5/20/16 7.99in 4.00in 4.01 in 12.60in2 36,020 2860 19.7 Type 2 1 5 7 KC -16-290 5/19/16 5/23/16 1 8.03in 4.01 in 4.O1in 12.63in2 47,170 3730 25.7 Type 3 KC -16-291 5/19/16 5/25/16 8.02in 4.00in 4.Ozin 12.63in2 49,750 3940 27.2 Type 3 28 KC -16-292 5/19/16 6/15/16 8.00in 4.00in 4.01 in 12.60in2 64,580 5130 35.4 Type 3 28 KC -16-293 5/19/16 6/15/16 8.02in 4.00in 4.02in I 12.63in2 65,820 1 5210 35.9 Ristury of Inaiviauai cwmpressiva Strungtn i casts For This Prujaut dna Mix ID Remarks: -Reference: WSDOT Std. Specifications 6-02.3{D & 6-02.3(5). Field tests performed using ASTM C31/C31M, C138, C143, C172, C231, and C1064. - �I ! 15 X meets Material above specificatiuns. Approved for e:r! et �r/� Tested and Dtsf udon By / Submiued By- cw Gi:�suls marenals Engineer Dat-. Initial Dale Form: Fiold Concrete Test Report Revised: 8121108 Second Most Recent First Most Recent Current Individual Strength Running Average Individual Strength Test individual Strength Test Test of the Three Most Recent Individual Strength Tests Date of Test 6/15/2016 6/15/2016 6/15/2016 ,Cylinder Strength 5130psi 5190 si 4790psi 4840psi 5130 si 5210 si Avera a Strength 5160psi 4820psi 5170psi I 5650 si Remarks: -Reference: WSDOT Std. Specifications 6-02.3{D & 6-02.3(5). Field tests performed using ASTM C31/C31M, C138, C143, C172, C231, and C1064. - �I ! 15 X meets Material above specificatiuns. Approved for e:r! et �r/� Tested and Dtsf udon By / Submiued By- cw Gi:�suls marenals Engineer Dat-. Initial Dale Form: Fiold Concrete Test Report Revised: 8121108