Loading...
HomeMy WebLinkAboutR-420214� �OHW_ N � --__2LLJ0___w \ -- 0 _------- \�19 eEiCITEf;FOIV END CONCRETE PANEL, TYP ------ RAVLSi�9U�D€� --- �\ EMBANKMENT BOULDERS AT G7 EDGE OF GRAVEL SHOULDER TYP � L-7 SS HANDRAIL 1 TYP T-5 3i� L \ END POST L-4 SPACING, TYP go � oa CONCRETE BRIDGE a a Q APPROACH a a 4 6 aI < HMA APPROACH a a al a a cn � a as O GRAVEL SHOULDER a a 08It ) / -----22------21-- 41-1 1/4", TYP pw /MHO517 z CONC APPROACH SLAB HMA APPROACH --\ Cl) I` LO Lf ) CID o RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE c`n° LICENSED ENGINEER OR LANDSCAPE ARCHITECT. in c� J BRIDGE CENTERLINE 7'-8 211 4'-112" T-3 16" 4'-112" L FRP LUMBER 2 HANDRAIL TYP NOTES: L-4 1. TYPICAL POST SPACING FOR HANDRAIL IS APPROXIMATELY T-5 3/4" O.C. EXCEPT WHERE SHOWN DIFFERENTLY. 2. SPACING OF HANDRAIL IS TO BE PERPENDICULAR AND PARALLEL AND MATCH ON BOTH SIDES OF THE BRIDGE. 3. PLACE CONTROL JOINTS AND EXPANSION JOINTS IN CONCRETE PERIMETER BAND CENTERED BETWEEN POSTS AS SHOWN ON THE PLAN. 4. SEE DRAWING L-3 FOR MODIFIED SPACING AT OVERLOOK. 5. RELOCATED BOULDERS ARE SHOWN FOR DESIGN INTENT ONLY. CONTRACTOR SHALL VISIT PROJECT SITE AND BE FAMILIAR WITH BOULDER TYPE/SIZES TO BE RELOCATED PRIOR TO PROJECT BID. SS HANDRAIL 1 TYP END POST L-4 SS END POST RAIL SUPPORT - SEE STRUCTURAL EL 24.3' 5 FRP LUMBER L-4 CLADDING LAYOUT REPLACE EXIST RIP -RAP � " WITHIN PREVIOUS FOOTPRINT, GRATING BRIDGE PLAN 7'-8 1"T-5 3'� 1„ SPACING, TYP SCALE: 5 0 5 10 1"=5' scale feet CONCRETE BRIDGE TYP APPROACH ENLARGEMENT f 1-21------- LO L 2 F, / � ------ �- 9 C:) EXPANSION — — — — . -- N JOINTS, TYP / RAVEL SHOULDER O a 4a a vv a a ° M a \ M SAW-CUHMA APPROACH � a I JOINTS, TYP I� 41 GRAVEL SH LDER N a I O O O O \ N CONTROL — Q 1 JOINTS, TYP \------------�\ L-2 L TYP. �J 20 SS HANDRAIL END POST LEGEND ORDINARY HIGH WATER MARK ". PROPOSED CONCRETE -20- - ------ _ — — _1 g — EXISTING CONTOURS EXPANSION JOINTS EXISTING LIGHT POLE ----------- CONTROL JOINTS - EXISTING JUNCTION BOX PROPOSED GRAVEL EXISTING CONIFER TREE RELOCATED BOULDERS EXISTING DECIDUOUS TREE FRP LUMBER 2 TYP PRE FAB SS 3 TYP HANDRAIL L-4 WEBNET PANNELS L-4 SS TWO POST RAIL BASE PL - SS MID POST RAIL 4 TYP SEE 2 SUPPORT (TOP) L-4 S-12 INTERPRETIVE SIGN LOCATION - CONCRETE TOPPING OVER SEE OVERLOOK FOR DETAILS EXTERIOR GIRDERS I BRIDGE & HANDRAIL L 2 BOTTOM OF BRIDGE 3 \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \ OVERLOOK EXISTING LAKE BOTTOM SURFACE 2 BRIDGE ELEVATION - SCALE: 5 0 5 10 1" = 5' scale feet ,3F WASH P �\� E wo" 0 1 RECORD DRAWING DEW 0/26/2 GDN SURVEYED: SCALE: OPy 9 2 1 =20 WSP USA Inc. 33301 9th Avenue South co DESIGNED: DEW + Suite 300 Federal Way, WA 98003-2600 o N n� DRAWN: Si ONE INCH TEL: (206) 431-2300 FAX: (206) 431-2250 ss �o \ 7 � F fig\ C,'r `1� s�`O 0 1 CHECKED: AT FULL SCALE DEW IF NOT ONE INCH o G� P6o SCALE ACCORDINGLY �gNDSCAPE NO. REVISION BY DATE APPR APPROVED: n, GDN 12MM SS STRUT WELDED TO MID POST RAIL SUPPORTS EL 24.3' CONC APPROACH SLAB /-- HMA APPROACH CONC ABUTMENT, TYP - STEEL PILE, TYP R-420214 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT BRIDGE PLAN &ELEVATION 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: L-1 SHEET: OF: 18 45 C'7 O O O T C