HomeMy WebLinkAboutR-420224O 0 W CODES, SPECIFICATIONS, STANDARDS, PRACTICES 1. AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICALS (AASHTO) "LRFD GUIDE SPECIFICATIONS FOR THE DESIGN OF PEDESTRIAN BRIDGES", DECEMBER 2009. 2. AASHTO "LRFD BRIDGE DESIGN SPECIFICATIONS", NOVEMBER 2017. 3. AMERICAN CONCRETE INSTITUTE (ACI) "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE", ACI 318-19. > 4. ACI "SPECIFICATIONS FOR STRUCTURAL CONCRETE", ACI 301-20. m 5. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) "SPECIFICATION V) FOR STRUCTURAL STEEL BUILDINGS", AISC 360-16 6. AMERICAN WELDING SOCIETY (AWS) "BRIDGE WELDING CODE", AWS Q D1.5-2020 AND "STRUCTURAL WELDING CODE - REINFORCING STEEL" AWS D1-4-2018. Q 2 U) 7. INTERNATIONAL BUILDING CODE (IBC) 2018 EDITION � 8. WASHINGTON STATE DEPARTMENT OF TRANSPORTATION "STANDARD SPECIFICATION FOR ROADS, BRIDGES, AND MUNICIPAL PUBLIC WORKS CONSTRUCTION", 2020 EDITION. (WSDOT SPEC) L DESIGN LOADS 61 0) 1. DEAD LOADS: ACTUAL WEIGHT OF MATERIALS 2. UNIFORM PEDESTRIAN LIVE LOAD ON BRIDGE: 90 PSF 3. DESIGN VEHICLE: 14' _C 4,000 LBS 16,000 LBS HS-10 TRUCK LOAD COMBINATIONS STRENGTH I: (1.25MAX,0.9MIN)DC+1.75(LL OR PED LL) STRENGTH III: (1.25MAX,0.9MIN)DC+1.0WS EXTREME EVENT I: 1.ODC+1.0(LL OR PED LL) SERVICE I: 1.ODC+1.0(LL OR PED LL) SERVICE II: 1.ODC+1.3(LL OR PED LL) DC = DEAD LOAD OF STRUCTURAL COMPONENTS AND NON STRUCTURAL ATTACHMENTS LL = VEHICULAR LIVE LOAD PED LL = PEDESTRIAN LIVE LOAD WS = WIND ON STRUCTURE 1. PIPE PILE MATERIAL: ASTM A 252, GRADE 3, YIELD STRENGTH = 50 KSI 2. COAT PIPE PILES IN ACCORDANCE WITH THE SPECIFICATIONS. REPAIR COATING IN ACCORDANCE WITH THE SPECIFICATIONS. 3. DRIVEN PILE REQUIRED CAPACITIES: TENSION: 33 KIPS (ULTIMATE) COMPRESSION: 135 KIPS (ULTIMATE), 105 KIPS (WORKING) < Q 4. NOTIFY THE CITY IF ANY PILE IS DRIVEN BEYOND THE TOLERANCES OR 00 DOES NOT ACHIEVE THE PILE TIP ELEVATIONS NOTED OR ON THE co DRAWINGS. N CD N N 01 Ell 0 LO LO ro RECORD DRAWING METAL FABRICATIONS 1. STRUCTURAL PLATES, SHAPES, AND W-SHAPES FOR BRIDGE: ASTM A 709, YIELD STRENGTH = 50 KSI. 2. HSS SECTIONS: ASTM A1085, YELD STRENGTH = 50 KSI 3. CHANNELS AND ANGLES: ASTM A36, YIELD STRENGTH = 36 KSI 4. PIPE: ASTM A53, GRADE B. 5. THREADED RODS: ASTM F1554, GRADE 55. 6. BOLTS: ASTM F3125 GRADE A325 TYPE 1 OR 3, UNLESS OTHERWISE NOTED. 7. NUTS: HEAVY HEX, ASTM A 563, GRADE SUITABLE FOR THE TYPE OF ROD. PROVIDE DOUBLE NUTS OR A HEAVY HEX NUT AND LOCK NUT. 8. WASHERS: ASTM F 844, WIDE SERIES, MAXIMUM THICKNESS. 9. SUBMIT WELD PROCEDURES AS REQUIRED PER THE SPECIFICATIONS. 10. PERFORM WELDING IN ACCORDANCE WITH AWS D1.5 USING WABO CERTIFIED WELDERS, WELDING OPERATORS, AND TACK WELDERS IN THE CERTIFIED PROCESS AND WELDING POSITION FOR THE QUALIFIED JOINT WELDING PROCEDURES. PREPARE JOINTS TO FIT PROPERLY FOR THE APPROPRIATE WELD AS INDICATED ON THE DRAWINGS. INSPECT ALL WELDS. 11. REMOVE APPLIED GALVANIZATION AND COATINGS PRIOR TO FIELD WELDING OF STEEL ELEMENTS. RESTORE GALVANIZATION AND/OR COATING AFTER COMPLETION OF FIELD WELDING. MAT =L ITT E RMT-S, F M R I CATI O 11'S'A ND"AS S ACCORDANCE WITH THE SPECIFICATIONS. 13. RESTORE COATINGS DAMAGED BY WELDING, HANDLING, OR OTHER CAUSESIN ACCORDANCE -WITH -THE SP�CIFICATION.S- - 14. SUBMIT CERTIFICATES OF COMPLIANCE FROM FABRICATORS OF PREFABRICATED STRUCTURAL STEEL MEMBERS AT THE COMPLETION OF FABRICATION AS REQUIRED PER IBC 1704.2.5 AND 1704.2.5.1. 1. MATERIAL: HILTI HIT -RE 500-SD EPDXY ADHESIVE ANCHORING SYSTEM WITH HOT -DIP GALVANIZED FASTENERS. 2. INSTALL IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. 3. DRILL HOLES USING A PERCUSSION DRILL WITH A CARBIDE BIT. 4. SET ANCHORS USING TEMPLATES VERIFIED WITH THE FABRICATION ANCHOR SPACING. 1. REINFORCED CONCRETE: MINIMUM 28-DAY COMPRESSIVE STRENGTH = 5000 PSI 2. CONCRETE IN -FILL FOR PIPE PILES: MINIMUM 28-DAY COMPRESSIVE STRENGTH = 5000 PSI 3. REINFORCING STEEL: ASTM A 706, GRADE 60, DEFORMED. 5. GROUT: ASTM C 1107, NON-FERROUS, NON-METALIC, MEETING THE FOLLOWING ADDITIONAL REQUIREMENTS. MINIMUM WORKING TIME _ 30 MINUTES FLUID CONSISTENCY (ASTM C 939) = 25 TO 30 SECONDS MINIMUM COMPRESSIVE STRENGTH (28 DAYS) = 8000 PSI. 6. INSTALL CORNER BARS AT ALL CORNERS. MATCH THE NUMBER, SPACING, AND DIAMETER OF ALL HORIZONTAL REINFORCING STEEL AT THE CORNERS. 7. SUBMIT TO THE BUILDING OFFICIAL WELD PROCEDURES SPECIFICATIONS INCLUDING PROCEDURE QUALIFICATION RECORDS FOR WELD PROCEDURES NOT PREQUALIFIED BY AWS OF CONCRETE REINFORCEMENT OTHER THAT BY FILLET WELDS 8. WELD ALL REINFORCING STEEL IN ACCORDANCE WITH AWS D1.4 USING CERTIFIED WELDERS AND QUALIFIED WELDING PROCEDURES. INSPECT ALL WELDS. 9. WELD HEADED STUDS USING AUTOMATICALLY TIMED WELDING EQUIPMENT IN ACCORDANCE WITH AWS D1.1. co THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED USA Inc. 333 IN PART ON INFORMATION PROVIDED BY OTHERS. 3301 9th Avenue South Suite 300 CHANGES SHOWN HAVE BEEN PROVIDED BY THE Federal Way, WA 98003-2600 > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE TEL: (206) 431-2300 CIO 1 LICENSED ENGINEER OR LANDSCAPE ARCHITECT. FAX: (206) 431-2250 W ca J 0 NO. ADDENDUM 1 REVISION 2 CONCRETE (CONTINUED 10. DETAIL REINFORCING STEEL IN ACCORDANCE WITH ACI 315. REINFORCING STEEL BEND DIMENSIONS SHOWN ARE OUT TO OUT. USE SEISMIC HOOK DETAILS FOR TIES AND STIRRUPS UNLESS OTHERWISE SHOWN ON THE DRAWINGS. 11. LAP SPLICES FOR REINFORCING STEEL THAT IS LESS THAN 40 FEET IN LENGTH IS NOT PERMITTED. REINFORCING STEEL GREATER THAN 40 FEET IN LENGTH WILL BE ALLOWED WITH A MINIMUM LAP SPLICE LENGTH OF 50 TIMES THE DIAMETER OF THE BAR. 12. PROVIDE 3-INCHES OF CONCRETE COVER UNLESS OTHERWISE SHOWN ON THE DRAWINGS. CHAMFER EXPOSED CORNERS 3/4-INCH. 13. CONSTRUCTION JOINTS SHALL HAVE A 1/4-INCH AMPLITUDE ON THE ROUGHENED SURFACE, CONTINUOUS ACROSS THE ENTIRE SURFACE. 14. CONCRETE FORMING: SEE THE SPECIFICATIONS. FILL VOIDS LEFT BY CONES AND OTHER FORMWORK HARDWARE AFTER FORMS ARE REMOVED. FOR CHAIRS, SUPPORTS, AND SPACERS TO SUPPORT 2% REINFORCING STEEL, SEE THE SPECIFIATIONS. PROVIDE CHAIRS, SUPPORTS, AND SPACERS AT INTERVALS LESS THAN 4 FEET ON CENTER UNLESS OTHERWISE ALLOWED BY THE CITY. REVISION 15. CONCRETE FINISHING: TERMINOLOGY IS DEFINED IN ACI 301. SLAB OR TOPPING SURFACES = LIGHT BROOM FINISH W/ STRIA OF %6" FORMED SURFACES = SMOOTH FORM FINISH SURFACES RECEIVING GROUT = SCRATCH FINISH 16. CONCRETE CURING: MOIST CURE CONCRETE SURFACES OR USE AN APPROVED CURING MEMBRANE IN ACCORDANCE WITH ACI 301 UNLESS A LONGER TIME IS REQUIRED IN THE SPECIFICATIONS. 17. CONCRETE DEFECTS: REPAIR FORMED SURFACES BY REMOVING MINOR HONEYCOMBS, PITS GREATER THAN 1/2-SQUARE-INCH IN AREA OR GREATER THAN 1/4-INCH IN DEPTH, AND ALL OTHER DEFECTS AS DIRECTED BY THE CITY OR AS DESCRIBED IN THE SPECIFICATIONS OR REFERENCE DOCUMENTS. PROVIDE EDGES PERPENDICULAR TO THE SURFACE, PATCH WITH GROUT AS SPECIFIED ABOVE, AND PROVIDE A SMOOTH FORM FINISH. CONCRETE WITH EXTENSIVE HONEYCOMBING OR OTHER DEFECTS WHICH AFFECT SERVICEABILITY AND/OR STRUCTURAL STRENGTH OF THE CONCRETE ELEMENT, AS DETERMINED BY THE CITY, SHALL BE REJECTED AND REPLACED AT NO ADDITIONAL COST TO THE CITY. METAL GRATING 1. METAL GRATING SHALL BE HOT DIPPED GALVANIZED STEEL TO ASTM A 123, ADA COMPLIANT AND SUPPORT A LIVE LOAD OF 90 PSF, OR A POINT LOAD OF 8,000 LBS ON ONE SQUARE FOOT. 2. BEARING BARS SHALL BE 2 INCH HIGH BY 3/16 INCH THICK SPACED AT 1/2 INCH OC. 3. TRANSVERSE BARS SHALL BE SPACED AT 4 INCHES OC. 4. METAL GRATING SHALL BE SHOP FABRICATED BASED ON AS -BUILT STRUCTURE DIMENSIONS (FIELD CUTTING IS NOT ALLOWED). 5. HOT -DIP GALVANIZE AND APPLY NON-SKID FINISH TO GRATING AFTER FABRICATION. 6. METAL GRATING SHALL BE SHOP FABRICATED BASED ON AS -BUILT STRUCTURE DIMENSIONS (FIELD CUTTING IS NOT ALLOWED). 7. METAL GRATING FASTENERS SHALL BE MECHANICAL FASTENERS PER THE GRATING MANUFACTURER, MEETING ADA REQUIREMENTS. 8. MAXIMUM SPACING OF THE METAL GRATING FASTENERS WILL BE DETERMINED BY THE GRATING MANUFACTURER. STRUCTURAL SPECIAL INSPECTION 1. TESTING AND SPECIAL INSPECTION SHALL BE PER THE TABLES ON SHEET 1A AS REQUIRED PER THE IBC AND AISC 360-16, AND AS REQUIRED IN THE SPECIFICATIONS. GDN 2/9/22 GDN SURVEYED: SCALE: GDN 8/11/22 GDN DESIGNED: GDN DRAWN: AHK CHECKED: CS13 BY DATE AP P R APPROVED: GDN 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY R-420224 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT STRUCTURAL NOTES 10/26/23 FIEW130OK: FB PAGE` PAGE DRAWING NO: S-1 SHEET: OF: 28 45 O O CD O T N a J M C'7 O O O T