Loading...
HomeMy WebLinkAboutzR-4202Set0 • MAYOR: ARMONDO PAVONE RENTON CITY COUNCIL: RANDY CORMAN RYAN MCIRVIN VALERIE O'HALLORAN RUTH PEREZ KI M-KHAN H VAN ED PRINCE ANGELINA BENEDETTI GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT COMMUNITY SERVICES DEPARTMENT: KELLY BEYMER, COMMUNITY SERVICES ADMINSTRATOR LESLIE BETLACH, PARKS PLANNING AND NATURAL RESOURCES DIRECTOR ALAN J. WYATT, CAPITAL PROJECTS MANAGER LO LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE LICENSED ENGINEER OR LANDSCAPE ARCHITECT. J WSP USA Inc. NNN 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 fl- ti� �P L PACIFIC OCEAN 1201 LAKE WASHINGTON BLVD NORTH RENTON, WASHINGTON CANADA BELLINGHAM Z�p ROJECT%� ----------------- — OCATION � EVEREn --------------------�� �XSEATTLE OLYMPIA OREGON RENTON TACOMA El El 0 11 El C3 -1 �]j 1-1 Li ELI onoq d o o Q� ��q ]❑ E�C C]H�� q�a��❑4�� DaD�qo u o ol_ o ET�ir--u AVF NF o 405 ❑ dam° Goa 0 000 o� o � Sa-�� \k� o o B�vON O Sao , O PSN\NG�ON Ro 0 Q:D APPROXIMATE SHORELINE PARK TRAILS GENE COULON MEMORIAL BEACH PARK PUBLIC DOCKS 0 El �*_ D 0 -< C Z m 70 O 0 AREA MAP SCALE: NTS VICINITY MAP SCALE: NTS R-420201 IN COMPLIANCE WITH CITY OF RENTON STANDARDS SURVEYED: SCALE: DATE: 10/26/23 DESIGNEDGDN 1 20 CITY OF GENE COULON MEMORIAL BEACH PARK FlELDBOOK: FB RENTON TRESTLE BRIDGE REPLACEMENT PAGE: PAGE DRAWN: AH K DRAWING NO: ONE INCH CHECKED: CSB AT FULL SCALE IF NOT ONE INCH COVER SHEET G — 1 APPROVED: SHEET: 1 OF, 45 NO. REVISION BY DATE AP P R SCALE ACCORDINGLY N O O O O T N a J O O T Uu uu o ❑Q N Nt N � ❑ flJ � rim L� Ej E0 E�� E:J= E—L] JONES AVE NE E] EE] Imo.. O i f-1 0 = RESTROOM TO BE CLOSED, CONTRACTOR TO SUPPLY TEMPORARY FACILITIES — 1. C.UUKUIIVAI It IVIUVtIVItIV I Ur ALL UUIVJI KUI,I IUIV IJAKCjtJ VVI I hi I hit U I Y PRIOR TO MOVEMENT. SAIL MOORINGS ARE LOCATED BOTH NORTH AND SOUTH OF THE WORK AREA. J=410101011]IVell9W4I01019SITTT Its] :iw_\71Z61MI0IFel 2110FTALTAIk9:talk fma: Eels ft, Co MOBILIZATION. co O CN 3. MAINTAIN CLEAR AREA FOR EMERGENCY VEHICLE TURNAROUND AND ACCESS IN THE TRAFFIC CIRCLE. WEI �. 0 4. SEE CIVIL DRAWINGS FOR LAYDOWN AND RESTORATION REQUIREMENTS. 0) r- LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED >, IN PART ON INFORMATION PROVIDED BY OTHERS. -0 CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE in LICENSED ENGINEER OR LANDSCAPE ARCHITECT. J WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 D. NF wasZ,���� o � 502z 6-- � LISTER y� ss1oNAL �o�� N 0. n6 u❑ [�J E::�i P r=�] E�;] E:�] ED PLAN - SITE ACCESS SCALE: NTS SURVEYED: DESIGNED: GDN DRAWN: AHK CHECKED: CSB REVISION BY DATE APPR APPROVED: GDN p Ejo 0 o SCALE: 1 "=20' CITY OF RENTON ONE INCH AT FULL SCALE • IF NOT ONE INCH SCALE ACCORDINGLY LO N LO O U ,O CW O O O T a J \\\ \ X > R-420203 IN COMPLIANCE WITH CITY OF RENTON STANDARDS GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT PLAN - EXISTING CONDITIONS 10/26/23 RELDBOOK: FB PAGE` PAGE DRAWING N0: G-3 SHEET: OF: 3 45 M M O O O T N O 0 W LEGEND ji 0- w w- OHW — OHP — Q 0 ao o� LO LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASE[ IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE LICENSED ENGINEER OR LANDSCAPE ARCHITECT. c� J JUNCTION BOX LIGHT POLE UTILITY POLE TREES WATER LINE ORDINARY HIGH WATER LINE OVERHEAD POWER LINE HANDRAIL WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 STERN' 0 ALA' o�� I-"AII I I I K 1 r' rrl%Ir`r LAKE WASHINGTON --\, PLAN - EXISTING TIMBER TRESTLE SCALE: 8 0 8 16 1"=8' scale feet SURVEYED: SCALE: DESIGNED: 1 "=20' � GDN + DRAWN: AHK ONE INCH CHECKED: AT FULL SCALE CSB IF NOT ONE INCH NO. REVISION BY DATE AP P R APPROVED: GDN SCALE ACCORDINGLY CITY OF RENTON R-420204 IN COMPLIANCE WITH CITY OF RENTON STANDARDS GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT SITE PLAN - EXISTING TIMBER TRESTLE BRIDGE z 3 Q 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: G-4 4 45 N LO O O N U N O O O O T a J C'7 C'7 O O O O T rr n 0 N 0 W GENERAL 1. THESE NOTES CONTAIN GENERAL INFORMATION AND ARE NOT NECESSARILY COMPLETE FOR CONSTRUCTION PURPOSES. VERIFY INFORMATION SHOWN ON THE DRAWINGS WITH OTHER DOCUMENTS AND BRING CONFLICT(S) TO THE ATTENTION OF THE CITY BEFORE BEGINNING THE AFFECTED WORK. THE CITY WILL RESOLVE THESE CONFLICT(S). 2. PROJECT DATUM AND SURVEY CONTROL: REFER TO NOTES ON DRAWING G-02 AND SURVEY BY SITTS AND HILL ENGINEERS, INC, COMPLETED ON 30 APRIL,2020. 3. ALL SURVEYING AND STAKING REQUIRED DURING CONSTRUCTION SHALL BE PERFORMED BY THE CONTRACTOR. 4. THE PARK TRAIL NEAR THE WORK WILL BE CLOSED TO THE PUBLIC DURING CONSTRUCTION. SUBMIT A TRAFFIC CONTROL PLAN TO THE CITY FOR REVIEW AND APPROVAL PRIOR TO THE START OF CONSTRUCTION. 5. CONTRACTOR AREAS FOR STAGING, LAYDOWN, STORAGE OF MATERIALS AND EQUIPMENT SHALL BE COORDINATED WITH THE CITY PRIOR TO MOBILIZATION TO THE SITE. 6. KEEP ALL ON -SITE PROJECT AREAS CLEAN AT ALL TIMES BY SWEEPING. WASHING AND/OR USE OF WATER TRUCK TO CLEAN PAVED AREAS ARE/IS NOT ALLOWED. 7. SITE FEATURES NOT SPECIFICALLY ADDRESSED IN PROJECT SPECIFICATIONS SHALL BE CONSTRUCTED IN ACCORDANCE WITH APPLICABLE MATERIAL AND CONSTRUCTION REQUIREMENTS SECTION OF WSDOT M41-10, STANDARD SPECIFICATION FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION, 2020, UNLESS NOTED OTHERWISE. DIVISION 1 AND MEASUREMENT AND PAYMENT SECTIONS OF WSDOT M41-10 DO NOT APPLY TO THIS PROJECT. 8. FIELD SURVEY PERFORMED WAS USED TO SHOW APPROXIMATE LOCATION OF EXISTING UNDERGROUND UTILITIES AND SITE FEATURES. HOWEVER, IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HERE IN WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THESE PLANS. USE A UTILITY LOCATION SERVICE FOR ALL AREAS REQUIRING EXCAVATION. INFORM THE CITY OF ANY POTENTIAL CONFLICTS OR INTERFERENCES FOR RESOLUTION PRIOR TO PERFORMING EXCAVATION. 9. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. 10. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR DETERMINING THE ADEQUACY OF EXISTING STRUCTURES AND UTILITIES TO SUPPORT CONSTRUCTION LOADS. 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL INSTALL AND MAINTAIN SHORING AND BRACING NECESSARY TO PROTECT WORKERS, UTILITIES AND OTHER IMPROVEMENTS AND EXCAVATION PER FEDERAL, STATE & CITY REGULATIONS. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR REMOVAL OF TEMPORARY SHORING AND BRACING. 11. PROVIDE PEDESTRIAN SIGNS & TRAFFIC CONTROL DURING CONSTRUCTION. 12. INSTALL TEMPORARY CONSTRUCTION FENCE AROUND THE JOB SITE. 13. PROVIDE AND MAINTAIN TEMPORARY SEDIMENTATION COLLECTION FACILITIES TO ENSURE THAT SEDIMENT -LADEN WATER DOES NOT ENTER THE NATURAL OR PIPED DRAINAGE SYSTEM. REFER TO THE APPLICABLE DRAWINGS AND PROJECT SPECIFICATIONS FOR REQUIREMENTS AND DETAILS THAT ARE CONSIDERED THE MINIMUM TESC FEATURES REQUIRED DURING CONSTRUCTION. AS CONSTRUCTION PROGRESSES AND SEASONAL CONDITIONS DICTATE, MORE TESC FACILITIES MAY BE REQUIRED TO ENSURE COMPLETE SILTATION AND EROSION CONTROL OF THE PROJECT. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF CONTRACTOR TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY CONTRACTOR'S ACTIVITIES AND TO PROVIDE ADDITIONAL TESC FACILITIES THAT MAY BE NEEDED TO PROTECT ADJACENT LAND AND EXIST DRAINAGE FEATURES. REMOVE TESC FACILITIES AT COMPLETION OF THE PROJECT. 14. A TESC PLAN SHALL BE SUBMITTED AND APPROVED BY THE CITY PRIOR TO STARTING CONSTRUCTION ACTIVITIES.. 15. ANY DAMAGE INCURED TO ANY PART OF THE SITE OR BOUNDARY NOT SPECIFICALLY DESIGNATED FOR DEMOLITION SHALL BE REPAIRED, REPLACED, AND/OR RECONSTRUCTED BY THE CONTRACTOR, AT THE CONTRACTORS EXPENSE, TO THE PRE -DISTURBED CONDITIONS AS DIRECTED BY THE CITY. Q 16. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. r co N 17. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. N U ° 18. ALL DEVIATIONS FROM THESE PLANS SHALL BE RECORDED ON A SET OF "AS -BUILT" E ° OR RECORD DRAWINGS. THE CONTRACTOR SHALL SUBMIT "AS -BUILT" DRAWINGS TO THE CITY. Nt LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASEDI Suite 300 WSP USA Inc. IN PART ON INFORMATION PROVIDED BY OTHERS. 33301 9th Avenue South CHANGES SHOWN HAVE BEEN PROVIDED BY THE Federal Way, WA 98003-2600 > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE TEL: (206) 431-2300 cco LICENSED ENGINEER OR LANDSCAPE ARCHITECT. FAX: (206) 431-2250 W cU J DEMOLITION AND CONSTRUCTION 16. CONTAIN DEMOLITION WITHIN THE LIMITS DESIGNATED. DO NOT DAMAGE EXISTING STRUCTURES, UTILITIES, OR FACILITIES. 17. DO NOT ALLOW DEMOLITION, CONSTRUCTION, OR OTHER DEBRIS TO FALL ONTO THE SLOPE OR INTO THE WATER BY UTILIZING TARPS, FLOATS, OR OTHER MEANS. 18. MONITOR OVERWATER DEMOLITION AND CONSTRUCTION ACTIVITIES AND IMMEDIATELY REMOVE AND DISPOSE OF ANY DEMOLITION, CONSTRUCTION, OR OTHER DEBRIS THAT ENTERS THE WATER IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REGULATIONS AND PERMIT REQUIREMENTS. MODIFY CONTAINMENT METHODS IF MONITORING INDICATES THAT THE METHODS IN USE ARE NOT EFFECTIVE. 19. MAINTAIN TREE PROTECTION THROUGH NSTRUCTION IN ACCORDANCE 71Q� WITH THE PLANS AND DETAILS ON SHEE �4A 20. PERFORM WORK IN ACCORDANCE WITH PERMIT AND REGULATION REQUIREMENTS. 21. PRIOR TO GENERAL DEMOLITION, SAWCUT WHERE NOTED, OR OTHERWISE PROVIDE A SMOOTH CLEAN BREAK BETWEEN ITEMS THAT ARE TO BE DEMOLISHED AND ITEMS THAT ARE TO REMAIN. 22. DEMOLITION AND EXCESS CONSTRUCTION MATERIALS, EXCEPT AS NOTED, SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED AND DISPOSED OF. 23. THE REMOVAL, HANDLING, AND DISPOSAL OF DEMOLITION MATERIALS, INCLUDING CREOSOTE -TREATED AND OTHER TIMBERS, SHALL BE IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL REQUIREMENTS. PROPER DISPOSAL OF DEMOLITION AND CONSTRUCTION MATERIALS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FAMILIARIZE ITSELF WITH THE MATERIALS TO BE DISPOSED OF; FEDERAL, STATE, AND LOCAL REGULATIONS; AND PERMIT REQUIREMENTS. 24. WHEN MODIFYING OR TRIMMING EXISTING ELEMENTS IS REQUIRED, DO NOT DAMAGE OR REDUCE THE LOAD -CARRYING CAPACITY OF THE EXISTING ELEMENTS. HMA PAVING AND SURFACE RESTORATION 1. HMA SHALL BE CLASS 1/2-INCH, PG 58S-22 FOR TYPICAL PAVING SECTION, SEE A C-12 2. SAW -CUT AND CAREFULLY REMOVE EXISTING PAVEMENT IN A MANNER TO PREVENT DAMAGE TO CLEAN VERTICAL ACP EDGE. PAVEMENT MARKING AND SIGNAGE 1. REPLACE IN KIND ALL EXISTING PAVEMENT MARKING ON TRAIL (SUCH AS CENTER STRIPES) AS REQUIRED DUE TO CONSTRUCTION ACTIVITIES REQUIRING SURFACE DEMO. \A/OTFR 1. WATER GENERAL NOTES SHALL BE PER THE CITY OF RENTON STANDARD PLAN NO. 300, SEE SHEET C-8. 2. POT -HOLE AS REQUIRED TO CONFIRM ALL TIE-IN LOCATIONS, AND SIZE, MATERIAL, AND DEPTH OF EXISTING PIPE. NOTIFY THE CITY WHERE UNFORSEEN SITE CONDITIONS OR DISCREPANCIES ARE DISCOVERED. 3. WHERE EXISTING ACP IS REMOVED FOR PIPE INSTALLATION, REPAIR SECTION SHALL MATCH EXISTING BUT ALSO BE NOT LESS THAN 3" (MIN) ACP OVER 6" (MIN) COMPACTED BASE COURSE. TOP OF ACP SHALL BE FLUSH WITH EXIST. ALL PAVEMENT REMOVAL SHALL BE ACOMPLISHED USING SAW -CUTS. 4. WHERE WATER LINES ARE INSTALLED IN UNPAVED AREAS, SURFACE SHALL BE STABILIZED TO MATCH SURROUNDING CONDITIONS BY EITHER HYDRO -SEEDING WITH PERMANENT SEED MIX, PLACING LANDSCAPING BARK, OR PLACEMENT OF 3" THICK COMPACT CRUSHED AGGREGATE. 5. COORDINATE ALL UTILITY SHUTDOWNS WITH THE CITY OF RENTON PUBLIC WORKS. DISRUPTION OF ANY WATER SERVICE SHALL BE APPROVED IN ADVANCE. 1 1 UPDATED PER CIVIL APPLICATION PERMIT NO. REVISION EROSION AND SEDIMENTATION CONTROL BMP REQUIREMENTS THE FOLLOWING WASHINGTON STATE DEPARTMENT OF ECOLOGY TESC BMP'S SHALL BE USED AT THE PROJECT SITE AS REQUIRED FOR CONSTRUCTION STORMWATER POLLUTION PREVENTION AND PERMANENT EROSION CONTROL. REFER TO ECOLOGY'S 2019 STORMWATER MANAGEMENT MANUAL FOR WESTERN WASHINGTON (SWMMWW), JULY 2019, AND CITY OF RENTON SURFACE WATER DESIGN MANUAL (RSWDM), 2017 FOR REQUIREMENTS RELATED TO THE FOLLOWING BMP-S. OBTAIN A COPY OF SWMMWW USING THE FOLLOWING LINK: HTTPS://FORTRESS.WA.GOV/ECY/EZSHARE/WQ/PERMITS/FLARE/2019SWMMWW/2019SWMMWW.HTM THE BMP'S AND RELATED DESIGN AND INSTALLATION SPECIFICATIONS AND MAINTENANCE STANDARDS DESCRIBED FOR EACH BMP IN THE SWMMWW AND/OR RSWDM SHALL BE CONSIDERED CONTRACT REQUIREMENTS UNLESS OTHERWISE NOTED. 1. BMP C103: HIGH VISIBILITY FENCE - WHERE SILT FENCE IS NOT REQUIRED, INSTALL HIGH VISIBILITY FENCE AT LIMITS OF DISTURBANCE IN ACCORDANCE WITH BMP C103 AND WSDOT STD PLAN 1-10.10-01. WHERE SILT FENCE IS REQUIRED AT LIMITS OF DISTURBANCE, INSTALL HIGH VISIBILITY STILT FENCE IN ACCORDANCE WITH WSDOT STD PLAN 1-30.17-01 OR HIGH VISIBILITY SILT FENCE WITH BACKUP SUPPORT IN ACCORDANCE WITH WSDOT STD PLAN 1-30.16-01 AS REQUIRED TO MAINTAIN INTEGRITY OF SILT FENCE. 2. BMP C105: STABILIZED CONSTRUCTION ENTRANCE/EXIT - ALSO SEE WSDOT STD PLAN 1-80.10-02. 3. BMP C106: WHEEL WASH - ONLY REQUIRED WHEN BMP C105 IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO ROADWAY 4. BMP C140: DUST CONTROL 5. BMP C151: CONCRETE HANDLING 6. BMP C154: CONCRETE WASHOUT AREA 7. BMP C160: CERTIFIED EROSION AND SEDIMENT CONTROL LEAD. 8. BMP C233: SILT FENCE - ALSO REFER TO NOTES UNDER BMP C103 9. BMP C235: WATTLES SUGGESTED CONSTRUCTION SEQUENCE FOR TESC: 1. PRE -CONSTRUCTION MEETING 2. FLAG OR FENCE CLEARING LIMITS 3. POST SIGN WITH NAME AND PHONE NUMBER OF CERTIFIED TESC LEAD 4. GRADE AND INSTALL CONSTRUCTION ENTRANCE(S). 5. INSTALL PERIMETER PROTECTION (SILT FENCE, WATTLES, ETC.) 6. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH THE DEPARTMENT OF ECOLOGY STANDARDS AND MANUFACTURER'S RECOMMENDATIONS. 7. RELOCATE SURFACE WATER CONTROLS AND EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE THE EROSION AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE DEPARTMENT OF ECOLOGY EROSION AND SEDIMENT CONTROL STANDARDS. 8. COVER ALL AREAS WITH TESC FEATURES THAT WILL BE UNWORKED FOR MORE THAN SEVEN DAYS DURING THE DRY SEASON OR TWO DAYS DURING THE WET SEASON IN ACCORDANCE WITH THE SPECIFICATIONS. 9. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN SEVEN DAYS. 10. UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS SHALL BE STABILIZED AND TESC BEST MANAGEMENT PRACTICES REMOVED IF APPROPRIATE AS DETERMINED BY THE CITY. GDN 3/17/221 GDN SURVEYED: DESIGNED: GDN. DRAWN: AHK CHECKED: CSB BY DATE AP P R APPROVED: GDN SCALE: 1 "=20' ONE INCH AT FULL SCALE • IF NOT ONE INCH SCALE ACCORDINGLY R-420206 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT CIVIL NOTES 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: C-1 SHEET: OF: 6 45 N O O O T a J M 0 O O T N Er n O 0 W m U) a� U) E Q U QI U) D 0 i OHW i FC;FNn 0# 0 PLANTING NORTH AREA EXIST JUNCTION BOX EXIST LIGHT POLE EXIST UTILITY POLE EXIST TREES (SEE DRAWING C-4 FOR PROTECTION DETAILS) EXIST FENCE ORDINARY HIGH WATER LINE SILT FENCE FLOATING DEBRIS BOOM HIGH VISIBILITY FENCE EXIST TREE W/ TREE PROTECTION SEE DRAWING C-4 o_ Nt LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE cco LICENSED ENGINEER OR LANDSCAPE ARCHITECT. in m J WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 AREA OF DISTURBANCE, TYP EXIST PEDESTRIAN ACP TRAIL TESC NOTES: 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR. 2. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORMWATER GENERAL PERMIT, IF IT IS REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT. 3. THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION COMMENCEMENT TO POST -PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS. 4. THE ESC FACILITIES SHOWN ON THIS PLAN MUST BE CONSTRUCTED PRIOR TO OR IN CONJUNCTION WITH ALL CLEARING AND GRADING SO AS TO ENSURE THAT THE TRANSPORT OF SEDIMENT TO SURFACE WATERS, DRAINAGE SYSTEMS, AND ADJACENT PROPERTIES IS MINIMIZED. 5. THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND THEIR BUFFERS, AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. 6. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK -OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING WATERS OF THE STATE. 7. WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF -SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN DITCHES. ON -SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE WASHOUT AREAS. 1 1 UPDATED PER CIVIL APPLICATION PERMIT NO. REVISION I� EXIST CONIC F&�TING, TYP EXIST TIMBER TRESTLE ra m M. n • III111�11 ■■■■ — ------ 10 --- �I ♦ EXIST PEDESTRIAN ACP TRAIL PLAN - TEMPORARY EROSION AND SEDIMENT CONTROL SCALE: 20 0 20 40 1" = 20' scale feet 8. ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON -SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT. 9. ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY. 10. THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATE D SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROV IDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 11. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 12. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1ST THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM. 13. WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1ST AND APRIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY. 14. ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS. 15. THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY. GDN 3/22/221 GDN SURVEYED: DESIGNED: GDN. DRAWN: AHK CHECKED: CSB BY DATE AP P R APPROVED: GDN SCALE: 1 "=20' ONE INCH +H AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY PUBLIC RESTROOM 16. BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216.30 SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION. 17. AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2/3 OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM. 18. PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW. 19. ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. R-420207 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT TESC PLAN 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: C-2 SHEET: OF: 45 N 0 0 O O i T N a J M m O O O O T O i N 0 W m U) ry U) Q U U) D I O 0 U DRIPLINE OF DIA OF BASE 1.25', WHICF GREATER (SE TEMP CHI CONSTRUI CFF r\inTF 2 DETAIL - INDIVIDUAL TREE PROTECTION SCALE: NTS TREE PROTECTION NOTES: DRIPLINE OF DIA OF BASE 1.25', WHICF GREATER (SE TEMP CHP CONSTRU( 5v-w MAX PncT CPA 1. TREE PROTECTION SHALL BE INSTALLED PRIOR TO START OF CONSTRUCTION ACTIVITIES AND REMAIN THROUGHOUT THE WORK AS NECESSARY TO PROTECT EXISTING VEGETATION TO REMAIN. 2. PROTECT ALL TREES AND OTHER PLANT MATERIAL SCHEDULED TO REMAIN. DO NOT PARK ANY VEHICLES OR EQUIPMENT, STORE MATERIALS OR STOCKPILED SOIL, DISPOSE OF BUILDING MATERIALS, CHEMICALS, PETROLEUM PRODUCTS, OR OTHER DETRIMENTAL SUBSTANCES WITHIN LIMITS OF TREE PROTECTION FENCING OF ANY EXISTING TREE TO REMAIN. PROTECT EXISTING TREES FROM FLAME, SMOKE, AND HEAT. CONSTRUCTION ACCESS TO SITE SHALL NOT OCCUR BENEATH DRIP LINE OF EXISTING TREES UNTIL SPECIAL PROVISIONS HAVE BEEN MET TO PROTECT ALL EXISTING VEGETATION TO REMAIN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGE TO EXISTING TREES AND PLANT MATERIAL DURING CONSTRUCTION. ALL CLEARING AND GRUBBING OR EXCAVATION WITHIN LIMITS OF TREE PROTECTION FENCING SHALL BE DONE BY HAND METHODS. 3. A TEMPORARY CHAIN LINK CONSTRUCTION FENCE SHALL BE INSTALLED AROUND THE GREATER OF THE PROTECTED TREE DRIPLINE OR SURROUNDING A TREE AT A DISTANCE EQUAL TO OR GREATER THAN 1.25 FEET FOR EACH 1-INCH OF TRUNK WIDTH LOCATED 3-FEET ABOVE THE LOWEST GRADE. TEMPORARY FENCE SHALL BE INSTALLED TO SURROUND TREE(S). 4. TEMPORARY CHAIN LINK FABRIC TO BE MINIMUM 11 GAUGE, GALVANIZED. DO NOT USE RUSTED OR MALFORMED FABIC. 5. POSTS SHALL BE GALVANIZED 2"0 STANDARD PIPE POSTS, OR APPROVED EQUAL. INSTALL POSTS TO AVOIDED DAMAGE TO MAJOR ROOTS, AND WITH SUFFICIENT EMBEDMENT TO SUPPORT FENCE. CONCRETE FENCE POST FOOTINGS ARE ACCEPTABLE OVER PAVED SURFACES. 6. ROOTS 1-INCH IN DIAMETER AND GREATER EXPOSED DURING CONSTRUCTION SHALL HAVE A CLEAN STRAIGHT CUT TO REMOVE DAMAGED PORTION OF ROOT, AND ALL EXPOSED ROOTS SHALL BE COVERED WITH TOPSOIL IMMEDIATELY TO PREVENT DRYING. 7. INDIVIDUAL TREES SHALL HAVE TEMPORARY FENCING PLACE ON FOUR SIDES, WITH PLACARDS INSTALLED ON EACH SIDE. PLACARDS SHALL HAVE THE FOLLOWING WORDS, "NO TRESPASSING - PROTECTED TREES". 8. WHERE EXCAVATING FOR NEW CONSTRUCTION IS REQUIRED WITHIN LIMITS OF TREE PROTECTION FENCING, EXCAVATE BY HAND TO MINIMIZE DAMAGE TO ROOTS AND PERFORM AS FOLLOWS: A. USE NARROW TINE SPADING FORKS AND COMB SOIL TO EXPOSE ROOTS. I B. IF MAIN LATERAL ROOTS ARE IMMEDIATELY ADJACENT TO LOCATION OF NEW CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE PRIOR TO ANY EXCAVATION. Q 7 C. DO NOT ALLOW EXPOSED ROOTS TO DRY OUT BEFORE PERMANENT BACKFILL IS PLACED. co00 CV o D. PROVIDE TEMPORARY EARTH COVER AND/OR MOIST ORGANIC MULCH, OR PACK WITH PEAT MOSS AND WRAP WITH BURLAP. WATER AND MAINTAIN THE MOIST CONDITION UNTIL COVERED WITH N BACKFILL. U 0 0 9. ANY TREE EXCEEDING 12 INCHES IN CALIPER AND LARGER, MEASURED 3 FEET ABOVE THE LOWEST GRADE IMMEDIATELY ADJACENT TO THE TREE IS CONSIDERED A SIGNIFICANT EXISTING TREE. ANY m DAMAGE TO A SIGNIFICANT EXISTING TREE SHALL IMMEDIATELY BE REPORTED TO THE CITY. Nt LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE LICENSED ENGINEER OR LANDSCAPE ARCHITECT. c� J WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 NO. REVISION DETAIL - MULTIPLE TREE PROTECTION SCALE: NTS SURVEYED: DESIGNED: GDN DRAWN: AHK CHECKED: CSB BY DATE AP P R APPROVED: GDN SCALE: 1 "=20' ONE INCH AT FULL SCALE • IF NOT ONE INCH SCALE ACCORDINGLY CITY OF RENTON R-420209 IN COMPLIANCE WITH CITY OF RENTON STANDARDS GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT DETAILS - TREE PROTECTION z 3 Q 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: C-4 9 45 L0 N LO O O N U N O O O O T a J C'7 C'7 O O O O T O 0 LU L 0 (2) ry Q U Q U) D I O 0 U — OHP — P( wow PARK TRAIL, TYP — OHP — x — OHP — ---------------------------- 20 �9 LEGEND x — OHP — — OHP — X n V — OHP X a J❑ EXIST JUNCTION BOX LO EXIST LIGHT POLE O a EXIST UTILITY POLE EXIST TREES ti w w — EXIST WATER LINE z 0 E EXIST ELECTRICAL CONDUIT OHW ORDINARY HIGH WATER LINE - OHP— OVERHEAD POWER LINE U r, EXIST HANDRAIL EXISTING ASPHALT PAVEMENT DEMOLITION (ASSUME 3" THICK FOR BASIS OF BID) N 00 co N o TREE PROTECTION REQUIRED, SEE DRAWING C-4 N FOR DETAILS U 0 C O O� LO LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE c`n° LICENSED ENGINEER OR LANDSCAPE ARCHITECT. c� J WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 D.NVA 1�r� 1 2 GISTEV'- 0 S�01VAr x X X X — OHP — — A PLAN - DEMOLITION TIMBER TRESTLE SCALE: 8 0 8 16 1"=8' scale feet UPDATED PER CIVIL APPLICATION PERMIT RECORD DRAWING REVISION GDN 3/22/22 GDN SURVEYED: GDN 10/26/2 GDN DESIGNED: GDN DRAWN: AHK CHECKED: CSB BY DATE AP P R APPROVED: GDN SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY �OHP— 2 _X X — OHP — — OHP — 23 22 NOTES: III — OHP — 23 x 24 WP NORTHING EASTING W P 1 1301827.3032 189361.2657 W P2 1301793.2818 189457.1240 1. SEE DRAWING L-1 FOR THE LIMITS OF CLEARING AND GRUBBING. 2. SEE DRAWING C-4 FOR TREE PROTECTION REQUIREMENTS. 3. INSTALL A TEMPORARY MJ CAP AND RESTRAINT JOINT AND 2" BLOWOFF ON EXISTING DUCTILE IRON PIPE BY THE CITY OF RENTON FORCES. PRIOR TO INSTALLATION OF TEMPORARY CAP COORDINATE OUTAGE WITH THE CITY. 4. POT -HOLE EACH WATER PIPE CONNECTION LOCATION TO CONFIRM LOCATION AND DEPTH OF EXISTING PIPE AT LOWER 22.5 DEG BEND PRIOR TO DEMOLITION. R-42021 0 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT PLAN -DEMOLITION EXISTING BRIDGE 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: C-5 SHEET: 10 OF. 45 N O O O O T a J C'7 C'7 O O O O i T CV n O 0 W — OHP— �__------- ----- ---- _--------------=23--- - _- \-- --- 1r — --- ------- -I - -� -----------22-----------------23-- �___ -20 _ --- — 20- —--------------- ------ �\ - - - - - - --_ _ — _ — -20 m � Q \ // \ I EXIST LIGHT POLE /// I I \ / / I c------- 19--- lg OHM� / -- TO REMAIN, TYP // I -20 (L ABUTMENT 2 (L ABUTMENT 1 - 21- - _ -21�-' z MATCH EXIST GRADE o-'22------ ��� -21 - _--- \ --- _ —OHP— \---------- _—_— _ _ ---- `YS _ -23- Q - 22- --- - - 21 - EXIST ACP TRA LO LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE LICENSED ENGINEER OR LANDSCAPE ARCHITECT. c� J a-W.W099dall HMA PAVEMENT, TYP WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 D. N� waskl'►'GJ'O GISTV, 0 S�ONAL� pG� NO. 22- - _ _ _ _ MATCH EXIST GRADE — RAILING, TYP - A APPROX EL 23.5 Qa ---------------------------------------------------- _ _ _::= - - - - - - - - - - - - - - - - d / GRATED DECKING - OVERLOOK / 2 TAPER __---_ _-- ,9� -2 PLAN - TRAIL GRADING & PAVING SCALE: 8 0 8 16 1"=8' scale feet L, \ 1 .., 1 I V I L %:.-, 1 ,-%,-" \J 1 L I 1 V V L ELEVATION - TRAIL GRADING SCALE: 8 0 8 16 1" = 8' scale feet REVISION SURVEYED: DESIGNED: GDN DRAWN: AHK CHECKED: JJV BY DATE AP P R APPROVED: GDN SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY rI 1A 7 -17\--7-- ST ACP TRAIL LO Lid � Q T N U � Oi i i i T l v 0 rTl W EXIST ACP PARK TRAIL, TYP N R-420212 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT PLAN &ELEVATION -TRAIL GRADING 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: C-11 SHEET. OF. 16 45 H H T N a J co O O O T N n � �OHW_ N � --__2LLJ0___w \ -- 0 _------- \�19 eEiCITEf;FOIV END CONCRETE PANEL, TYP ------ RAVLSi�9U�D€� --- �\ EMBANKMENT BOULDERS AT G7 EDGE OF GRAVEL SHOULDER TYP � L-7 SS HANDRAIL 1 TYP T-5 3i� L \ END POST L-4 SPACING, TYP go � oa CONCRETE BRIDGE a a Q APPROACH a a 4 6 aI < HMA APPROACH a a al a a cn � a as O GRAVEL SHOULDER a a 08It ) / -----22------21-- 41-1 1/4", TYP pw /MHO517 z CONC APPROACH SLAB HMA APPROACH --\ Cl) I` LO Lf ) CID o RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE c`n° LICENSED ENGINEER OR LANDSCAPE ARCHITECT. in c� J BRIDGE CENTERLINE 7'-8 211 4'-112" T-3 16" 4'-112" L FRP LUMBER 2 HANDRAIL TYP NOTES: L-4 1. TYPICAL POST SPACING FOR HANDRAIL IS APPROXIMATELY T-5 3/4" O.C. EXCEPT WHERE SHOWN DIFFERENTLY. 2. SPACING OF HANDRAIL IS TO BE PERPENDICULAR AND PARALLEL AND MATCH ON BOTH SIDES OF THE BRIDGE. 3. PLACE CONTROL JOINTS AND EXPANSION JOINTS IN CONCRETE PERIMETER BAND CENTERED BETWEEN POSTS AS SHOWN ON THE PLAN. 4. SEE DRAWING L-3 FOR MODIFIED SPACING AT OVERLOOK. 5. RELOCATED BOULDERS ARE SHOWN FOR DESIGN INTENT ONLY. CONTRACTOR SHALL VISIT PROJECT SITE AND BE FAMILIAR WITH BOULDER TYPE/SIZES TO BE RELOCATED PRIOR TO PROJECT BID. SS HANDRAIL 1 TYP END POST L-4 SS END POST RAIL SUPPORT - SEE STRUCTURAL EL 24.3' 5 FRP LUMBER L-4 CLADDING LAYOUT REPLACE EXIST RIP -RAP � " WITHIN PREVIOUS FOOTPRINT, GRATING BRIDGE PLAN 7'-8 1"T-5 3'� 1„ SPACING, TYP SCALE: 5 0 5 10 1"=5' scale feet CONCRETE BRIDGE TYP APPROACH ENLARGEMENT f 1-21------- LO L 2 F, / � ------ �- 9 C:) EXPANSION — — — — . -- N JOINTS, TYP / RAVEL SHOULDER O a 4a a vv a a ° M a \ M SAW-CUHMA APPROACH � a I JOINTS, TYP I� 41 GRAVEL SH LDER N a I O O O O \ N CONTROL — Q 1 JOINTS, TYP \------------�\ L-2 L TYP. �J 20 SS HANDRAIL END POST LEGEND ORDINARY HIGH WATER MARK ". PROPOSED CONCRETE -20- - ------ _ — — _1 g — EXISTING CONTOURS EXPANSION JOINTS EXISTING LIGHT POLE ----------- CONTROL JOINTS - EXISTING JUNCTION BOX PROPOSED GRAVEL EXISTING CONIFER TREE RELOCATED BOULDERS EXISTING DECIDUOUS TREE FRP LUMBER 2 TYP PRE FAB SS 3 TYP HANDRAIL L-4 WEBNET PANNELS L-4 SS TWO POST RAIL BASE PL - SS MID POST RAIL 4 TYP SEE 2 SUPPORT (TOP) L-4 S-12 INTERPRETIVE SIGN LOCATION - CONCRETE TOPPING OVER SEE OVERLOOK FOR DETAILS EXTERIOR GIRDERS I BRIDGE & HANDRAIL L 2 BOTTOM OF BRIDGE 3 \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \ OVERLOOK EXISTING LAKE BOTTOM SURFACE 2 BRIDGE ELEVATION - SCALE: 5 0 5 10 1" = 5' scale feet ,3F WASH P �\� E wo" 0 1 RECORD DRAWING DEW 0/26/2 GDN SURVEYED: SCALE: OPy 9 2 1 =20 WSP USA Inc. 33301 9th Avenue South co DESIGNED: DEW + Suite 300 Federal Way, WA 98003-2600 o N n� DRAWN: Si ONE INCH TEL: (206) 431-2300 FAX: (206) 431-2250 ss �o \ 7 � F fig\ C,'r `1� s�`O 0 1 CHECKED: AT FULL SCALE DEW IF NOT ONE INCH o G� P6o SCALE ACCORDINGLY �gNDSCAPE NO. REVISION BY DATE APPR APPROVED: n, GDN 12MM SS STRUT WELDED TO MID POST RAIL SUPPORTS EL 24.3' CONC APPROACH SLAB /-- HMA APPROACH CONC ABUTMENT, TYP - STEEL PILE, TYP R-420214 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT BRIDGE PLAN &ELEVATION 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: L-1 SHEET: OF: 18 45 C'7 O O O T C O I 0 W m 0 (2) ry U) Q U U) D IZ O 0 U ON CL CFF nRA\A/IIV(-1 -1 G(1R KAOMI lPn cDArIN(, ANIn I OrATIONI CFF nRA\A/In1(, 1 -1 G(1R cTOnInARn RAII cDArinl(, SS REINFORCING PLATE (SEE STRUCTURAL) SS TWO POST RAIL SUPPORT — SEE STRUCTURAL 4 L-4 SS MID POST RAIL SUPPORT ;BOTTOM) — SEE STRUCTURAL CONCRETE CAP CLADDING FASTENERS — SEE 3 S-11 U %-LMVVIIVIJ UVI I%JIVI %JIF UUNIVl7L VIIlVLUN co Lf ) Lfl o RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. -0 CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE c`n° LICENSED ENGINEER OR LANDSCAPE ARCHITECT. cU J WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 BRIDGE &HANDRAIL OUTSIDE ELEVATION SCALE: 1"=1'-0" BRIDGE & HANDRAIL SECTION SCALE: 1"=1'-0" � Ennnn wO T �� �d1111��9� 2 NO. RECORD DRAWING REVISION SS REINFORCING PLATE (SEE STRUCTURAL) PRE FAB SS 3 WEBNET PANELS L-4 SS TWO POST RAIL SUPPORT CONCRETE CAP 3/4" CHAMFER, TYP OVERHANG 12" X 716 FRP LUMBER CLADDING LUMBER CLADDING TO BE FLUSH WITH BOTTOM OF GIRDER DEW 10/26/21 GDN SURVEYED: DESIGNED: DEW DRAWN: SJ CHECKED: DEW BY DATE AP P R APPROVED: GDN SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY WOOD GRAIN FINISH ON ALL SIDES 12MM SS STRUT WELDED TO MID POST RAIL SUPPORTS — SS WEBNET 2" SS ROUND POSTS AND WEBNET FRAME (BEYOND) BRIDGE SIDE FRP LUMBER 2 HANDRAIL L-4 SS M I D POST RAIL 4 ~ SUPPORT (TOP) L-4 LO N PRE FAB SS 3 p WEBNET PANELS L-4 F� O T N Q U SS MID POST RAIL SUPPORT (BOTTOM) — SEE STRUCTURAL O CONCRETE TOPPING 3/4" CHAMFER, TYP N WATER SIDE O O O FRP LUMBER 2 O T CLADDING TYP. L-2 CAI a J INTERMEDIATE HANDRAIL SECTION SCALE: 1"=1'-0" 9'-911 BRIDGE ABUTMENT EXPANSION JOINTS — SEE STRUCTURAL Qa a' 1'-11 3/8" m 00 m a CONCRETE EDGECAP 1'-10 3/4" 3/4" L1--10 3/4" LEGEND ECOLORED COLORED CONCRETE CONCRETE ° WITH SPARKLE GRAIN 1'-11 3/8" CONCRETE BRIDGE PATTERN SCALE: 1"=1'-0" R-420215 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT BRIDGE &HANDRAIL ELEVATION AND SECTIONS 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: L-2 SHEET: OF: 1 45 M O O O O T N 0- 3/4" O N 0 W L a� ry U) 0) Fy Q U C Q U) I O m 0 U N 0 co N CD N N U 0 OVERLOOK PLAN SCALE: NTS 1 • FA 0 •••••••o I 1'�•••�••�11 •••�•••� �•••••••••••••�a ►�i����i�i�ii���i�i�i�i� ��i�i�i� ��i�l� ► •. ��►��i�i�i�i�i� ►�•iiii.! ii���i�i�i�i •••••••••••••� ........ ...... ,.e.... .....NR, 401 ..... ......,. ,.e.... . � .ti �.. . ��•�•�•�•�•�•�•� �iii••ii'�'01 1'•iiii�i �iiii �iii.�l:�•iii�iiii ►•iiiiir'�'�••iiii� ►•�•�•�•�•�•�•�- EXISTING LAKE BOTTOM SURFACE 3 OVERLOOK ELEVATION - SCALE: NTS Ln 0 RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE cco LICENSED ENGINEER OR LANDSCAPE ARCHITECT. U) CU J WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 o�� E. w0 1 1 RECORD DRAWING adll�Ib�9� Oh ~ s o � SF�� FkP. 10I0�1�G�G�`1'S \gNncraPE P�_� N0. HANDRAIL CONCRETE TOPE 1 1/2" X 7 7/16 LUMBER CLAD[ OVERLOOK BRIDGE OVERLOOK CROSS SECTION SCALE: NTS SS TWO POST 6 RAIL SUPPORT L-05 FRP LUMBER 2 HANDRAIL L-05 SS REINFORCING PLATE (SEE STRUCTURAL TYP CONCRETE TOPPING 1 1/4"0 STD SS PIPE WELDED TO FRS HANDRAIL SUPPORT PLATE FRP HANDRAIL SUPPORT ATTACHED TO PANEL, BEYOND WEBNET FRAME 2X3 FRP LUMBER ROUNDED SIGN FRAME WITH TAMPER PROOF STAINLESS STEEL WOOD SCREWS CLADDING FASTENERS (SEE STRUCTURAL) I — FRP LUMBER TYP. 1-2 J CLADDING L-02 C REVISION 1/8" SS SIGN FRAME 3/16" SS SUPPORT PLATE 120° SS FOUR POST RAIL SUPPORT, TYP 1"0 STD SS PIPE, MATCHING ANGLE OF FRP HANDRAIL SUPPORT PIPE 154.9° F= DUAL POSTS BEYOND WEB NET 00 N "A" CROSS SECTION L 3/16 3/16 00 M O N 1/8" SS FRAME 3/4", TYP SIGN FRAME SECTION 3'-0 3/8" O.C. 4", TYP 2X3 FRP LUMBER SIGN FRAME WITH TAMPER PROOF STAINLESS STEEL SCREWS L SS FOUR POST RAIL SUPPORT, TYP V-4 1 /2" TYP 1�d1�:�►1�1 INTERPRETIVE SIGN FRAME MOUNTING D SCALE: NTS DEW 10/26/2 GDN SURVEYED: DESIGNED: DEW DRAWN: SJ CHECKED: DEW BY DATE AP P R APPROVED: GDN SCALE: 1 "=20' + ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY SIGN FRAME PLAN 1/8" SS FRAME 1/8" x 1 1/2" x 1 1/2" SS ANGLE WELDED TO SS FRAME - SECURE FRP WITH VANDAL RESISTANT SCREWS 3/16" SS SUPPORT PLATE WELDED TO SS FRAME 24" x 36" INTERPRETIVE SIGN (BY OTHERS) 1---- 3/16" SS SUPPORT PLATE —INTERIOR FRAME EDGE 1/8" x 1 1/2" x 1 1/2" SS ANGLE REMOVABLE BOTTOM PANEL W/ VANDAL RESISTANT SCREWS MID POST RAIL SUPPORT �1 1/4"0 SS PIPE RAIL PLAN TOP VIEW 5'-11 3/4" O.C. 1'-10 3/4" SIGN 6NI (IN' ETAI LS PLATE SUPPORT SIGN FRAME, FRP CLADDING NOT SHOWN V-4 1 /2" 1"0 SS PIPE, TYP 4 1 1/4"0 SS PIPE 1/16" SS END CAP SEAL WELD, TYP WEBNET FRAME - 0216 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT OVERLOOK PLAN ELEVATION &SECTIONS 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: L-3 SHEET: OF: 20 45 Ln N Ln O O T U N O O 0 T N a J C'7 C'7 O O O i T N O N 0 W L m 0 (2) ry Q U Q U) D I O 0 U 3x10 FRP LUMBER HANDRAIL 2 650 CONNECTION _ TO REINFORCING PLATE SS REINFORCING PLATE - SEE STRUCTURAL 3(4) 2" SS ROUND POSTS 611 a SS WEBNET FRAME HOLDER PRE FAB SS 3 WITH VANDAL RESISTANT CAP WEBNET PANEL - SS WEBNET 'i C>1 SS HANDRAIL END POST (BACKSIDE) L-3 SCALE: 2"=1'-0" 1r=1=WmQ WA ml ml1\rW7 r-ei r,&'.7n FRP LUMBER TYP, CLADDING LAYOUT SCALE: 1/2"=1'-0" O BOLT PATTERN AT JOINT 1" GAP AT JOINT (NOT SHOWN) Q SEE STRUCTURAL o FOR BOLT FASTENERS co N CD N O C) O 6 BOLT PATTERN ENLARGEMENT M - SCALE: 11/2"=1'-0" Ln 0 RECORD DRAWING co THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE c`n° LICENSED ENGINEER OR LANDSCAPE ARCHITECT. c� J WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 1 3x10 FRP LUMBER HANDRAIL WITH 1/2"R EDGES, WOOD GRAIN ALL SIDES SS REINFORCING PLATE - SEE STRUCTURAL SS VANDAL RESISTANT FASTENERS MID POST RAIL 4 SUPPORT (BEYOND) - PRE FAB SS WEBNET PANEL 3 2" SS ROUND POSTS SS WEBNET FRAME CLAMP WATER SIDE NOTE: REFER TO SPECIFICATIONS FOR INSTALLATION AND MATERIAL INFORMATION. SS CLASPS ANCHORING SLOT FOR CABLE MESH 2 FRP LUMBER HANDRAIL SECTION 3 L-1 SCALE:2"=1'-0" L-1 L-2 L-2 L-3 L7rrwill iOG&'=NJS-=0�l Wi&VLl r"7AMIM[ftiEMU M IIIIIIIIX Ir\ YOMEl rr.7AM, 1 r■ r�l M mlr =1 r O IV s o SF� FkP. 10 \,4Nnczrl, P_� rN RECORD DRAWING REVISION 1 1/4" SS RAIL SUPPORT/WEBNET FRAME 1.5MM SS CABLE 2 " WOVEN WIRE MESH PRE FAB SS WEBNET PANELS SCALE: 2"=V-0" DEW 10/26/2 GDN I SURVEYED: DESIGNED: DEW DRAWN: SJ CHECKED: DEW BY DATE AP P R APPROVED: GDN SCALE: 1 "=20' ONE INCH AT FULL SCALE • IF NOT ONE INCH SCALE ACCORDINGLY 2 650 CC TO REI PLATE L-2 CL FRP LUMBER 2 HANDRAIL SS REINFORCING PLATE - SEE STRUCTURAL 1 1/4" SS TOP SUPPORT POST PRE FAB SS 3 WEBNET PANEL - EBNET TOP SUPPORT ELEVATION SS MID POST RAIL SUPPORT SCALE: 2"=1'-0" 4 RQInrF R-420217 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT RAILING DETAILS 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: L- 4 SHEET: 21 OF: 45 N O O O O T a J m C'7 O O O O T n LEGEND � j9 \ -20- \\ \ ' 1 I Oj 93 ; i ' � 1 I . — a a GRAVEL SHOULDER Q U) ASPHALT APPROACH a C/) ° a a a It0 O -_ 23-------- -2 -- - J / -----22------- --- 2 _ - -21- - - ---21------- - -20- 20- MHO-' 7- LO M LO Lf ) Lfl o RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE LICENSED ENGINEER OR LANDSCAPE ARCHITECT. in c� J EMBANKMENT BOULDERS TYP AT EDGE OF GRAVEL Q17 SHOULDER (TYP) CONCRETE BRIDGE APPROACH GRATING 'V E �w%0'/ c� 1 RECORD DRAWING WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 o N TEL: (206) 431-2300 ��� ss7 FAX: (206) 431-2250 `S`�O FkP, 10�� �,4NT771, ORDINARY HIGH WATER MARK _ 20 _1 g — EXISTING CONTOURS EXISTING LIGHT POLE EXISTING JUNCTION BOX \ EXISTING DECIDUOUS TREE BRIDGE PLAN -- j SCALE: 5 0 5 10 1"=5' scale feet REVISION OVERLOOK 1 PROPOSED CONCRETE PROPOSED GRAVEL RELOCATED BOULDERS DEW 10/26/2 GDN I SURVEYED: DESIGNED: DEW DRAWN: Si CHECKED: DEW BY DATE AP P R APPROVED: GDN BRIDGE CENTERLINE HANDRAILING, TYP SCALE: 1 "=20' CITY OF + RENTON ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY / 1 CONCRETE BRIDGE APPROACH / ,----------21------ N LO 22.__- ----- O N CU S O r 1 EXISTING TRAIL v a a a a a a a ASPHALT APPROACH41 GRAVEL SHOULDER N O $ O C:) i \ 2 ---- \ 20�� R-420218 IN COMPLIANCE WITH CITY OF RENTON STANDARDS GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT PLANTING PLAN AT BRIDGE 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: L-5 SHEET: OF: 22 45 cM O O O O T n O 0 W LAKE WASHINGTON EXIST. BEACH ACCESS NORTH PLANTING PLAN 20 0 20 40 scale feet PLANT SCHEDULE LEGEND NORTH PLANTING NOTES: TREES CODE QTY BOTANICAL NAME COMMON NAME SIZE REMARKS 9-i SL SHRUBS CODE 0 AC 0 FP MP 5 PICEA SITCHENSIS SITKA SPRUCE 5 GAL. 2 SALIX LUCIDA PACIFIC WILLOW 5 GAL. STRAIGHT SINGLE STEM QTY BOTANICAL NAME COMMON NAME SIZE REMARKS 9 ACER CIRCINATUM VINE MAPLE 5 GAL. 3 CANES (MIN.) 5 FRANGULA PURSHIANA CASCARA BUCKTHORN 5 GAL. 2 MALUS FUSCA WESTERN CRAB APPLE 5 GAL. 100 *GAULTHERIA SHALLON SALAL 1 GAL 24" O.C. 19 *ROSA PISOCARPA CLUSTERED WILD ROSE 1 GAL 48" O.C. * THE LAST TWO SHRUBS ARE TO BE DISTRIBUTED EVENLY WITHIN THE ENTIRE PLANTING ZONE. M LO Lf ) CID 0 RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE c`n° LICENSED ENGINEER OR LANDSCAPE ARCHITECT. in c� J WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 1 1 RECORD DRAWING NO. o EXIST JUNCTION BOX 3-o EXIST LIGHT POLE o EXIST TREES — WETLAND BUFFER APPROXIMATE ORDINARY HIGH WATER MARK - OHP- EXIST OVERHEAD POWER LINE EXIST CHAIN LINK FENCE DEW 0/26/2 GDN SURVEYED: DESIGNED: DEW DRAWN: Si CHECKED: DEW REVISION BY DATE APPR APPROVED: GDN 1. PLANTING AND MAINTENANCE SHALL CONFORM TO THE IMPLEMENTATION GUIDE FOR RESTORATION AND PERMITTING FOR LAKE WASHINGTON AND LAKE SAMMAMISH, JULY 25, 2019. 2. COORDINATE PLANTING LOCATIONS AND INSTALLATION WITH THE CITY OF RENTON CAPITAL PROJECTS MANAGER WITH PARKS PLANNING & NATURAL RESOURCES AND THE CITY URBAN FORESTER. 3. CALL 811 UTILITY LOCATE SERVICE 72 HOURS PRIOR TO IRRIGATION/PLANTING INSTALLATION. EXERCISE CARE TO PROTECT UNDERGROUND UTILITIES AND AVOID DISTURBING OR DAMAGING THEM IF PRESENT. 4. EXAMINE FINISH SURFACE, GRADES, TOPSOIL QUALITY AND DEPTH AND NOTIFY THE CITY OF RENTON REPRESENTATIVE OF ANY CONDITIONS WHICH MAY BE HARMFUL TO PLANT GROWTH. 5. THE EXISTING LAWN IN THE PROPOSED PLANTING AREA SHALL BE STRIPPED AND ROTOTILLED PRIOR TO IRRIGATION, PLANTING, AND MULCHING OPERATIONS. 6. SEE DRAWING L-7 FOR PLANTING AND TOPSOIL DETAILS 3-6. 7. TOP DRESS ENTIRE PLANTING BED AREA WITH 3-INCH LAYER OF BARK MULCH. KEEP MULCH 2-3 INCHES FROM STEMS OR TRUNKS. 8. BEAVER DETERRENT IS TO BE PROVIDED AROUND THE ENTIRE PERIMETER OF THE PLANTED AREJ 9. SEE DRAWING IR-2 FOR IRRIGATION PLAN AND MODIFICATION OF EXISTING IRRIGATION ZONES. SCALE: 1 "=20' ONE INCH AT FULL SCALE • IF NOT ONE INCH SCALE ACCORDINGLY _23- - R-420219 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT PLANTING PLAN NORTH AREA 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: L-6 SHEET: OF: 23 45 N O O O O T a J C'7 C'7 O O O O T I= n O 0 W SCARIFY SIDES AND BOTTOM BOTTOM OF R00- RESTS ON EXISTIN RECOMPACTED SC Vr RVV I DMLL SHRUB PLANTING SCALE: NTS NOTE: 1. SCARIFY BOTTOM AND SIDES tti OF HOLE PRIOR TO PLANTING. -•-`, r F - 2. TREE SHALL BE PLANTED SUCH' THAT THE TRUNK FLARE IS VISIBLE AT THE TOP OF THE ""` _ ROOT BALL. NO MULCH SHALL .. , COME IN CONTACT WITH THE ,F TREE TRUNK. MATCH TOP OF ROOT FLARE TO EXISTING GRADE SCARIFY SIDES OF I III=III PLANTING PIT PLACE ROOT BALL ON —I I, EST DIMENSIOIakI UNEXCAVATED OR — TAMPED SOIL OF ROOT BALL SET CROWN OF ROOTBALL 1" ABOVE FINISH GRADE PREPARED TOPSOIL A MULCH DEPTH AS SPECIFIED FERTILIZER TABLETS EXISTING SOIL ROOT BALL - ROUGHEN ROOTS PRIOR TO PLANTING MULCH DEPTH AS SPECIFIED ORIGINAL SLOPE SHOULD PASS THROUGH THE POINT WHERE THE TRUNK MEETS SUBSTRATE/SOIL — SLOPE SIDES OF LOOSENED SOIL TOPSOIL - DIG AND TURN THE SOIL TO REDUCE THE COMPACTION TO THE AREA AND DEPTH SHOWN BOTTOM OF ROOT BALL RESTS ON EXISTING OR RECOMPACTED SOIL DO NOT CUT LEADER, PRUNE DAMAGED WOOD PRIOR TO PLANTING CROWN 1" ABOVE GRADE 3 INCHES WOOD CHIP MULCH FERTILIZER TABLETS FINISHED GRADE PREPARED OR NATIVE TOPSOIL FIRMLY TAMP SOIL AROUND ROOT BALL SO ROOT BALL DOES NOT SHIFT NATIVE EVERGREEN TREE PLANTING SCALE: NTS APPLY SOIL AMENDMENTS AS RECOMMENDED BY THE SOIL ANALYSIS TILLER Ur- RVV I DMLL SECTION VIEW SHRUB PLANTING ON SLOPE SCALE: NTS NOTE: 1. SCARIFY BOTTOM AND SIDES OF HOLE PRIOR TO PLANTING. 2. EACH TREE SHALL BE PLANTED SUCH THAT THE TRUNK FLARE IS VISIBLE AT THE TOP OF THE ROOT BALL. NO MULCH SHALL COME IN CONTACT WITH THE TREE TRUNK. TOP OF ROOTBALL SHALL BE 1" ABOVE SURROUNDING GRADE SHRUB ROOT BALL - ROUGHEN ROOTS MASS PRIOR TO PLANTING CONSTRUCT ROUND TOPSOIL BERM AT ROOT BALL PERIPHERY - BERM SHALL BE 4" ABOVE ROOTBALL SURFACE AND 8" WIDE FERTILIZER TABLETS PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6" LIFTS TO BRACE SHRUB - DO NOT OVER COMPACT. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED, POUR WATER AROUND THE ROOT BALL TO SETTLE THE SOIL. *31�11►1EMT@]11 BEAVER DETERRENT - LOOSELY WRAP WITH 3 FOOT HIGH, GREEN PVC COATED WELDED WIRE MESH (1"x3" OPENING) AND MAINTAIN 6" CLEARANCE ON ALL SIDES OF PLANT MIULCH S WOOD CHIP FINISHED GRADE __ _ SCARIFY SIDES OF PREPARED OR �� —III PLANTING PIT NATIVE TOPSOIL FERTILIZER TABLETS PLACE ROOT BALL ON — — I I = _ _ _ -I I III— I FIRMLY TAMP SOIL UNEXCAVATED OR I I,,,I II; III —I I I=1I I —I I I—III=III—III—III= AROUND ROOT BALL TAMPED SOIL I I I III I �I I II �� SO ROOT BALL DOES VRdff IWELNOT SHIFT 4 NATIVE DECIDUOUS TREE PLANTING SCALE: NTS PROVIDE POSITIVE DRAINAGE s EVENLY SPREAD IMPORTED TOPSOIL 6" DEEP MIN. LO I I NATIVE SOIL AFTER III —III —III —III —I I —I I—1 I 1—I SOD REMOVAL IMIMIMIMIMIIEEIdI I1=� L —111—I I M 11-111-111-111—I I I —I I= U) I 1=1 FF;;;l1-111=1 I 1-1I1, ; ,1I1-1 I 1-1II-11 I-1II—I I _ — NOTES: —III- '11=III -III-1�11�11I11�11I1,�11I11111II1E��11---=���=��1=1I1 �111111;,111-111=1111-111111111I1 1I LL 1. IMPORT TOPSOIL TO BE SANDY LOAM SOIL FREE OF ROCKS, ROOTS, AND FOREIGN MATERIALS. CD 2. FERTILIZER APPLICATION SHOULD BE DELAYED IF PLANTING DOES NOT OCCUR WITHIN 2-3 DAYS OF FERTILIZING. O co I 3. FROZEN MATERIALS OR MATERIALS GREATER THAN 1" DIA. SHOULD BE REMOVED. N O N N 4. FINISH GRADE FOR ALL PLANTING BEDS ALONG WALKS OR CURBS SHOULD BE 3" LOWER THAN THE SURFACE. U O 0 K� 6 SOIL PREPARATION - PLANTING BED co - SCALE: NTS LO Ln o RECORD DRAWING co THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE c`n° LICENSED ENGINEER OR LANDSCAPE ARCHITECT. cU J WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 �� E . W0 1 1 RECORD DRAWING NO. PLACE B, CLUSTEF BARK MULCH REVISION EMBANKMENT BOULDERS SCALE: NTS DEW 10/26/2 GDN SURVEYED: DESIGNED: DEW DRAWN: SJ CHECKED: DEW BY DATE AP P R APPROVED: GDN SCALE: 1 "=20' + ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY NOTE: 1. SCARIFY BOTTOM AND SIDES OF HOLE PRIOR TO PLANTING it=Till � II I I-111. � 11'I'� I I -III -I I I- 2X'S WIDEST DIM. OF ROOT BALL BEAVER DETERRENT - LOOSELY WRAP WITH 3 FOOT HIGH, GREEN PVC COATED WELDED WIRE MESH (1"x3" OPENING) AND MAINTAIN 6" CLEARANCE ON ALL SIDES OF PLANT SET TOP OF POTTING SOIL 1" ABOVE FINISHED GRADE REMOVE CONTAINER FROM ROOT BALL, ROUGHEN ROOTBALL TO LOOSEN ROOTS 3" BARK MULCH DEPTH FINISHED GRADE FERTILIZER TABLETS PREPARED OR NATIVE TOPSOIL NATIVE OR COMPACTED SOIL NATIVE SHRUB PLANTING SCALE: NTS NOTES: 1. UTILIZE EXISTING ONSITE BOULDER AND > SITTING SUPPLEMENT AS REQUIRED MATCHING TYPE EL EDGE AND SIZE. - SHOULDER 2. SUPPLEMENTAL BOULDERS SHALL BE H PER CIVIL ACCEPTED BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 3. PLACEMENT HEIGHT OF BOULDERS VARY - BOULDERS SHALL BE PLACED IN GROUND 1/3 to 1/2 OF THEIR TOTAL HEIGHT FOR SIZES ABOVE 30-42" TALL AND 1/4 HEIGHT FOR BOULDERS THAT ARE LESS THAN 24" TALL. R-420220 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TH CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT PLANTING AND LANDSCAPE DETAILS 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: L-7 SHEET: OF: 24 45 N O O 0 T N a J M O O O T O N —OHW \ 19 \ —20_ _ \ 0 _----_--_—_ 2 _ �'�9 �.�__--- EMBANKEMENT BOULDERS, TYP 'j � a a O GRAVEL SHOULDER a 0) ASPHALT APPRAOCH 0 a EXISTING IRRIGATION m .fig HEADS, TYP q � — EXISTING PVC LATERAL LINE, TYP M rl- LO Ln CID 0 RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE c`n° LICENSED ENGINEER OR LANDSCAPE ARCHITECT. c� J RELOCATD EXISTING IRRIGATION ELECTRICAL WIRE IN 2" CONDUIT IRRIGATION NOTES: PEDESTRIAN BRIDGE IRRIGATION PLAN IR-1 SCALE: 5 0 5 10 1" = 5' scale feet LEGEND 1. CONTRACTOR SHALL REVIEW AS -BUILT DRAWINGS RELATIVE TO THE EXISTING UNDERGROUND UTILITIES AND EXISTING IRRIGATION SYSTEM. CONTRACTOR SHALL LOCATE HEADS, LATERALS AND IRRIGATION ELECTRICAL LINES PRIOR TO EXCAVATION OF AREAS. CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY IF UTILITIES NOT SHOWN ON THE AS -BUILT DOCUMENTS ARE ENCOUNTERED. 2. IRRIGATION CONTRACTOR IS RESPONSIBLE FOR TEMPORARILY RELOCATING THE ELECTRICAL LINE (LOCATED IN A 2" CONDUIT THAT CROSSES THE EXISTING BRIDGE) TO MAINTAIN IRRIGATION SYSTEM OPERATION FROM THE EXISTING CONTROLLER. CONTRACTOR SHALL COORDINATE INTERRUPTION OF ELECTRICAL SERVICE WITH THE OWNER. CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING MATERIALS AND LABOR TO PROVIDE TEMPORARY AND NEW ELECTRICAL SERVICE. ALL ELECTRICAL WORK SHALL BE PER LOCAL CODE. NEW CONNECTIONS SHALL BE MADE IN ELECTRICAL SPLICE BOXES. NEW ELECTRICAL SERVICE LINE LOCATION SHALL BE COORDINATED WITH THE BRIDGE CONTRACTOR. 3. COORDINATE WORK WITH ALL TRADES TO AVOID CONFLICTS WITH OTHER SITE IMPROVEMENTS. 4. PRESERVE AND PROTECT EXISTING TREES TO REMAIN. 5. IRRIGATION LINES IMPACTED DURING CONSTRUCTION SHALL BE FLUSHED AND CAPPED SO THAT THE SYSTEM CAN REMAIN IN OPERATION DURING CONSTRUCTION. 6. CONTRACTOR IS RESPONSIBLE FOR REPLACING EXISTING RAINBIRD IRRIGATION HEADS AND PVC LATERAL LINES WITH NEW TO MATCH EXISTING THAT ARE DISTURBED DURING CONSTRUCTION. CONTRACTOR SHALL ENSURE ADEQUATE WATER DISTRIBUTION TO NEW PLANTINGS. SEE DETAILS THIS SHEET FOR 7. AFTER REPAIRS ARE MADE, THE EXISTING IRRIGATION LINES HALL BE FLUSHED TO REMOVE ANY DEBRIS AND TO ENSURE THAT HEADS ARE OPERATING PROPERLY. 8. IRRIGATION EQUIPMENT NOT OTHERWISE DETAILED THAT MAY BE PRESENT, SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS. 9. IRRIGATION AND ELECTRICAL SLEEVES WHERE PRESENT SHALL MATCH EXISTING. ALL SLEEVES SHALL EXTEND AT LEAST 12" BEYOND CONCRETE STRUCTURES. ALLOW AT LEAST 4" - 6" FROM END OF SLEEVES TO FIRST FITTING ON IRRIGATION LINE. ALL SLEEVES SHALL BE 24" BELOW AND BE INSTALLED PRIOR TO CONCRETE OR PAVING WORK IF REQUIRED. 10. ALL PIPES SHALL BE TRENCHED AND BEDDED ON ALL SIDES WITH ROCK FREE (3/8" MINUS) MATERIAL. IMPORT SAND IF NECESSARY. BACKFILL IN TWO OR MORE COMPACTED LIFTS. SETTLING OF TRENCHES SHALL BE BROUGHT TO FINISH GRADE. 11. SEE DRAWING IR-3 FOR IRRIGATION DETAILS. �F WASiyi E . w L EXISTING PVC LATERAL LINE, TYP — EXISTING IRRIGATION HEADS, TYP CONCRETE RELOCATED BOULDERS WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 Q"����✓T9 CJ, coOP �y 9 2 _ o N � � F fig\ C,'r s�`O kP 10 G� 4gNDSCAPE P6o n, SURVEYED: SCALE: 1 „ =20, ' CITY OF RENTON DESIGNED: DEW DRAWN: SiI ONE INCH CHECKED: DEW AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY NO. REVISION BY DATE APPR APPROVED: GDN I� � � I OHW Ln / / I / ,�� --- ---- o p 20 N / -21-----------21---- 22-- -- -- — — — — — — -- 0 0 / — — — — —�------- r l ` a a EXISTING TRAIL N �a p ° O - - - - ASPHALT APPROACH p , a 4 O ° GRAVEL SHOULDER r N a° a � I 20co do co a — O _ O N R-420221 IN COMPLIANCE WITH CITY OF RENTON STANDARDS GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT IRRIGATION PLAN SCHEDULE & NOTES 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: R-1 SHEET: OF: 25 45 O I I W O� LO LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE LICENSED ENGINEER OR LANDSCAPE ARCHITECT. J EXIST. IRRIGATION VALVE RELOCATE EXISTING ROTOR SPRAY HEAD TO EDGE OF PROPOSED NEW PLANTING AREA AND ADJUST SPRAY LIMITS TO ACCOMMODATE NEW PLANTING AREA - !� REMOVE EXISTING ROTOR SPRAY HEADS AND CONNECTING LATERALS FROM NEW PLANTING AREA IRRIGATION SCHEDULE ���.�� �. � ..�.�+ ��� +� �•... � ...�� r+�. �'�'� r , + �� .ram ,� rr �. +mow � �.--� � � . �+ -+ • �T" �— NEW BATTERY OPERATED IRRIGATION REMOTE CONTROL VALVE - CONNECT TO EXISTING 4 INCH MAINLINE EXIST. CONIFER - HAND DIG IRRIGATION WITHIN 15' OF TREE IAInDT1-1 IDDIIrOTIif1Al DI DM 20 0 20 40 scale feet SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI DETAIL O O S 0 • RAIN BIRD 1806-SAM-PRS 15 SERIES MPR 20 30 Q T H TO F SHRUB SPRAY 6.0" POP-UP SPRINKLER WITH CO -MOLDED WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH SEAL-A-MATIC CHECK VALVE, AND PRESSURE REGULATING DEVICE. SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY DETAIL RAIN BIRD PGA GLOBE 1 111, 1-1/211, 2" ELECTRIC REMOTE CONTROL VALVE, GLOBE. IRRIGATION LATERAL LINE: PVC SCHEDULE 40 357.4 L.F. 1 I 22 - • 20- 4..r��9 A -f LAKE WASHINGTON NORTH IRRIGATION NOTES: 1. IRRIGATION AND MAINTENANCE SHALL CONFORM TO THE 5. THE EXISTING IRRIGATION CONTROLLER IS LOCATED SOUTH OF IMPLEMENTATION GUIDE FOR RESTORATION AND PERMITTING THE BRIDGE IN THE COMFORT STATION MAINTENANCE ROOM. FOR LAKE WASHINGTON AND LAKE SAMMAMISH, JULY 25, 2019. 2. EXISTING IRRIGATION SHOWN WAS REFERENCED FROM AS -BUILT DRAWINGS THAT ARE OLD. CONTRACTOR SHALL NOTE THAT THE EXISTING IRRIGATION SHOWN MAY NOT REPRESENT ACTUAL CONDITIONS ON SITE. CONTRACTOR WILL NEED TO VERIFY THE LOCATION OF EXISTING EQUIPMENT IN THE FIELD PRIOR WITH PARKS MAINTENANCE PERSONNEL PRIOR TO MAKING THE NECESSARY IRRIGATION IMPROVEMENTS. 3. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING IRRIGATION THAT IS IMPACTED BY NEW IMPROVEMENTS AND VERIFY THAT ALL IRRIGATION ZONES WORK PRIOR TO THE PROJECT BEING DEEMED COMPLETE. - - - - - - - - PIPE SLEEVE: PVC SCHEDULE 40 12.0 L.F. 4. CALL UTILITY LOCATE SERVICE 72 HOURS PRIOR TO IRRIGATION Valve Callout INSTALLATION. EXERCISE CARE TO PROTECT UNDERGROUND Valve Number UTILITIES AND AVOID DISTURBING OR DAMAGING THEM IF # �ValveNum PRESENT. Valve Size �F WASH CJ, SURVEYED: Mwoi/�9 oP ��l Vim' 7 WSP USA Inc. 33301 9th Avenue South � Z DESIGNED: DEW Suite 300 Federal Way, WA 98003-2600 o N �<" DRAWN: Si TEL: (206) 431-2300 `r6,7 �1`ti��� ti� CHECKED: DEW FAX: (206) 431-2250 `S`�O FkP. 10/° 4"44 SCAPE �6° NO. REVISION BY DATE APPR APPROVED: GDN 6. CONTRACTOR SHALL CONTACT THE CITY OF RENTON PARKS FACILITIES SUPERVISOR AND COORDINATE IRRIGATION RUN TIMES WITH THE EXISTING IRRIGATION ZONES. 7. SEE DRAWING IR-3 FOR IRRIGATION DETAILS. 8. IT IS UNCLEAR IF THE ORIGINAL IRRIGATION INSTALLATION INCLUDED SWING PIPES OR FUNNY PIPE FOR THE CONNECTION TO THE IRRIGATION HEAD. CONTRACTOR IS REQUIRED TO OBSERVE THE EQUIPMENT INSTALLATION DURING DEMOLITION AND MATCH THE EXISTING CONNECTIONS FOR CONSISTENCY. SCALE: 1 "=20' ONE INCH AT FULL SCALE • IF NOT ONE INCH SCALE ACCORDINGLY 7 R-420222 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT IRRIGATION PLAN SCHEDULE &NOTES 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: IR-2 SHEET: 26 OF: 45 C:) C:)O O T N a J C'7 C'7 O O 0 I T CV O N 0 W I— L m 0 ry Q U Q U) D I O 0 U NOTE: 1. TEMPORARY SLEEVE MARKER (2X4 OR PVC PIPE) AND TEMP. PVC SLEEVE CAP. TYPICAL PIPE & WIRE SLEEVING DETAIL SCALE: N.T.S. SPRAY HEAD NTS LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE c`n° LICENSED ENGINEER OR LANDSCAPE ARCHITECT. c� J CONCRETE, ASPHALT OR OTHER HARDSCAPE— SEE PLANS FOR CONDITIONS COMPACTED BASE ROCK SUBGRADE SAND BACKFILL, TYP— SEE SPECIFICATIONS CONTROL WIRES PVC PIPE PIPE SLEEVE, SEE PLANS FOR SIZE 1/2" REBAR MARKER (AT EACH END OF SLEEVE) WRAP WITH TRACE WIRE PLANTING BED WITH MULCH TOP OF SPRAY HEAD SLIGHTLY ABOVE MULCH AFTER SETTING POP-UP SPRAY HEAD PVC SCH. 40 STREET ELL MARLEX STREET ELL. TO BE THE SAME SIZE AS IRRIGATION HEAD INLET. WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 POLYETHYLENE TUBE - LENGTH AS REQUIRED (5' MAX) PVC SCH. 40 TEE OR ELL MARLEX STREET ELL LATERAL LINE FLUSH FINISH GRADE IRRIGATION ROTOR HEAD WITH CHECK VALVE SWING JOINT: 12" SWING FUNNY PIPE, BARBED ELBOWS (2), AND MARLEX STREET ELBOW LATERAL TEE OR ELBOW LATERAL PIPE ROTARY POPUP SPRINKLER HEAD SCALE: N.T.S. DETAIL LEGEND: O9 IRRIGATION CONTROLLER (HUNTER NODE-BT OR APPROVED EQUAL) AND MOUNTING HARDWARE PER PLAN OBATTERY OPERATED VALVE PER PLAN O3 VALVE BOX PER PLAN O4 MAIN LINE PER PLAN O5 MAIN LINE RISER PER PLAN O6 LATERAL LINE PER PLAN O7 GRAVEL BASE, DEPTH AS SPECIFIED O8 FILTER FABRIC O9 BRICK 10 FINISHED GRADE BATTERY OPERATED CONTROLLER NTS Z > DRAWN: .� S�N � SJ ONE INCH � 4' �1�L �� �.y CHECKEDDEW AT FULL SCALE SF FkP. 0I0 G '� IF NOT ONE INCH 4gNDSCAPE P6oG NO. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY n, GDN F, TRENCH DETAIL SCALE: N.T.S rI I Icu rinllcH L _L NOTE: 1. SLEEVE BELOW ALL HARDSCAPE ELEMENTS WITH SCHEDULE 40 PVC PIPE 2. FOR PIPE AND WIRE BURIAL DEPTHS SEE SPECIFICATIONS. CAUTION TAPE PVC LATERAL PIPE— SEE PLANS FOR SIZE YELLOW TRACE WIRE (TYP) 2" PVC PIPE SPACERS SET VERTICAL @ 10' O.C. PVC MAINLINE PIPE, SEE PLANS FOR SIZE SAND BACKFILL R-420223 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT IRRIGATION NOTES AND DETAILS 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: IR-3 SHEET: OF, 27 45 N C:) O O T a J C'7 C'7 O O C:) C:) T N n O 0 W CODES, SPECIFICATIONS, STANDARDS, PRACTICES 1. AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICALS (AASHTO) "LRFD GUIDE SPECIFICATIONS FOR THE DESIGN OF PEDESTRIAN BRIDGES", DECEMBER 2009. 2. AASHTO "LRFD BRIDGE DESIGN SPECIFICATIONS", NOVEMBER 2017. 3. AMERICAN CONCRETE INSTITUTE (ACI) "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE", ACI 318-19. > 4. ACI "SPECIFICATIONS FOR STRUCTURAL CONCRETE", ACI 301-20. m 5. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) "SPECIFICATION V) FOR STRUCTURAL STEEL BUILDINGS", AISC 360-16 6. AMERICAN WELDING SOCIETY (AWS) "BRIDGE WELDING CODE", AWS Q D1.5-2020 AND "STRUCTURAL WELDING CODE - REINFORCING STEEL" AWS D1-4-2018. Q 2 U) 7. INTERNATIONAL BUILDING CODE (IBC) 2018 EDITION � 8. WASHINGTON STATE DEPARTMENT OF TRANSPORTATION "STANDARD SPECIFICATION FOR ROADS, BRIDGES, AND MUNICIPAL PUBLIC WORKS CONSTRUCTION", 2020 EDITION. (WSDOT SPEC) L DESIGN LOADS 61 0) 1. DEAD LOADS: ACTUAL WEIGHT OF MATERIALS 2. UNIFORM PEDESTRIAN LIVE LOAD ON BRIDGE: 90 PSF 3. DESIGN VEHICLE: 14' _C 4,000 LBS 16,000 LBS HS-10 TRUCK LOAD COMBINATIONS STRENGTH I: (1.25MAX,0.9MIN)DC+1.75(LL OR PED LL) STRENGTH III: (1.25MAX,0.9MIN)DC+1.0WS EXTREME EVENT I: 1.ODC+1.0(LL OR PED LL) SERVICE I: 1.ODC+1.0(LL OR PED LL) SERVICE II: 1.ODC+1.3(LL OR PED LL) DC = DEAD LOAD OF STRUCTURAL COMPONENTS AND NON STRUCTURAL ATTACHMENTS LL = VEHICULAR LIVE LOAD PED LL = PEDESTRIAN LIVE LOAD WS = WIND ON STRUCTURE 1. PIPE PILE MATERIAL: ASTM A 252, GRADE 3, YIELD STRENGTH = 50 KSI 2. COAT PIPE PILES IN ACCORDANCE WITH THE SPECIFICATIONS. REPAIR COATING IN ACCORDANCE WITH THE SPECIFICATIONS. 3. DRIVEN PILE REQUIRED CAPACITIES: TENSION: 33 KIPS (ULTIMATE) COMPRESSION: 135 KIPS (ULTIMATE), 105 KIPS (WORKING) < Q 4. NOTIFY THE CITY IF ANY PILE IS DRIVEN BEYOND THE TOLERANCES OR 00 DOES NOT ACHIEVE THE PILE TIP ELEVATIONS NOTED OR ON THE co DRAWINGS. N CD N N 01 Ell 0 LO LO ro RECORD DRAWING METAL FABRICATIONS 1. STRUCTURAL PLATES, SHAPES, AND W-SHAPES FOR BRIDGE: ASTM A 709, YIELD STRENGTH = 50 KSI. 2. HSS SECTIONS: ASTM A1085, YELD STRENGTH = 50 KSI 3. CHANNELS AND ANGLES: ASTM A36, YIELD STRENGTH = 36 KSI 4. PIPE: ASTM A53, GRADE B. 5. THREADED RODS: ASTM F1554, GRADE 55. 6. BOLTS: ASTM F3125 GRADE A325 TYPE 1 OR 3, UNLESS OTHERWISE NOTED. 7. NUTS: HEAVY HEX, ASTM A 563, GRADE SUITABLE FOR THE TYPE OF ROD. PROVIDE DOUBLE NUTS OR A HEAVY HEX NUT AND LOCK NUT. 8. WASHERS: ASTM F 844, WIDE SERIES, MAXIMUM THICKNESS. 9. SUBMIT WELD PROCEDURES AS REQUIRED PER THE SPECIFICATIONS. 10. PERFORM WELDING IN ACCORDANCE WITH AWS D1.5 USING WABO CERTIFIED WELDERS, WELDING OPERATORS, AND TACK WELDERS IN THE CERTIFIED PROCESS AND WELDING POSITION FOR THE QUALIFIED JOINT WELDING PROCEDURES. PREPARE JOINTS TO FIT PROPERLY FOR THE APPROPRIATE WELD AS INDICATED ON THE DRAWINGS. INSPECT ALL WELDS. 11. REMOVE APPLIED GALVANIZATION AND COATINGS PRIOR TO FIELD WELDING OF STEEL ELEMENTS. RESTORE GALVANIZATION AND/OR COATING AFTER COMPLETION OF FIELD WELDING. MAT =L ITT E RMT-S, F M R I CATI O 11'S'A ND"AS S ACCORDANCE WITH THE SPECIFICATIONS. 13. RESTORE COATINGS DAMAGED BY WELDING, HANDLING, OR OTHER CAUSESIN ACCORDANCE -WITH -THE SP�CIFICATION.S- - 14. SUBMIT CERTIFICATES OF COMPLIANCE FROM FABRICATORS OF PREFABRICATED STRUCTURAL STEEL MEMBERS AT THE COMPLETION OF FABRICATION AS REQUIRED PER IBC 1704.2.5 AND 1704.2.5.1. 1. MATERIAL: HILTI HIT -RE 500-SD EPDXY ADHESIVE ANCHORING SYSTEM WITH HOT -DIP GALVANIZED FASTENERS. 2. INSTALL IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. 3. DRILL HOLES USING A PERCUSSION DRILL WITH A CARBIDE BIT. 4. SET ANCHORS USING TEMPLATES VERIFIED WITH THE FABRICATION ANCHOR SPACING. 1. REINFORCED CONCRETE: MINIMUM 28-DAY COMPRESSIVE STRENGTH = 5000 PSI 2. CONCRETE IN -FILL FOR PIPE PILES: MINIMUM 28-DAY COMPRESSIVE STRENGTH = 5000 PSI 3. REINFORCING STEEL: ASTM A 706, GRADE 60, DEFORMED. 5. GROUT: ASTM C 1107, NON-FERROUS, NON-METALIC, MEETING THE FOLLOWING ADDITIONAL REQUIREMENTS. MINIMUM WORKING TIME _ 30 MINUTES FLUID CONSISTENCY (ASTM C 939) = 25 TO 30 SECONDS MINIMUM COMPRESSIVE STRENGTH (28 DAYS) = 8000 PSI. 6. INSTALL CORNER BARS AT ALL CORNERS. MATCH THE NUMBER, SPACING, AND DIAMETER OF ALL HORIZONTAL REINFORCING STEEL AT THE CORNERS. 7. SUBMIT TO THE BUILDING OFFICIAL WELD PROCEDURES SPECIFICATIONS INCLUDING PROCEDURE QUALIFICATION RECORDS FOR WELD PROCEDURES NOT PREQUALIFIED BY AWS OF CONCRETE REINFORCEMENT OTHER THAT BY FILLET WELDS 8. WELD ALL REINFORCING STEEL IN ACCORDANCE WITH AWS D1.4 USING CERTIFIED WELDERS AND QUALIFIED WELDING PROCEDURES. INSPECT ALL WELDS. 9. WELD HEADED STUDS USING AUTOMATICALLY TIMED WELDING EQUIPMENT IN ACCORDANCE WITH AWS D1.1. co THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED USA Inc. 333 IN PART ON INFORMATION PROVIDED BY OTHERS. 3301 9th Avenue South Suite 300 CHANGES SHOWN HAVE BEEN PROVIDED BY THE Federal Way, WA 98003-2600 > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE TEL: (206) 431-2300 CIO 1 LICENSED ENGINEER OR LANDSCAPE ARCHITECT. FAX: (206) 431-2250 W ca J 0 NO. ADDENDUM 1 REVISION 2 CONCRETE (CONTINUED 10. DETAIL REINFORCING STEEL IN ACCORDANCE WITH ACI 315. REINFORCING STEEL BEND DIMENSIONS SHOWN ARE OUT TO OUT. USE SEISMIC HOOK DETAILS FOR TIES AND STIRRUPS UNLESS OTHERWISE SHOWN ON THE DRAWINGS. 11. LAP SPLICES FOR REINFORCING STEEL THAT IS LESS THAN 40 FEET IN LENGTH IS NOT PERMITTED. REINFORCING STEEL GREATER THAN 40 FEET IN LENGTH WILL BE ALLOWED WITH A MINIMUM LAP SPLICE LENGTH OF 50 TIMES THE DIAMETER OF THE BAR. 12. PROVIDE 3-INCHES OF CONCRETE COVER UNLESS OTHERWISE SHOWN ON THE DRAWINGS. CHAMFER EXPOSED CORNERS 3/4-INCH. 13. CONSTRUCTION JOINTS SHALL HAVE A 1/4-INCH AMPLITUDE ON THE ROUGHENED SURFACE, CONTINUOUS ACROSS THE ENTIRE SURFACE. 14. CONCRETE FORMING: SEE THE SPECIFICATIONS. FILL VOIDS LEFT BY CONES AND OTHER FORMWORK HARDWARE AFTER FORMS ARE REMOVED. FOR CHAIRS, SUPPORTS, AND SPACERS TO SUPPORT 2% REINFORCING STEEL, SEE THE SPECIFIATIONS. PROVIDE CHAIRS, SUPPORTS, AND SPACERS AT INTERVALS LESS THAN 4 FEET ON CENTER UNLESS OTHERWISE ALLOWED BY THE CITY. REVISION 15. CONCRETE FINISHING: TERMINOLOGY IS DEFINED IN ACI 301. SLAB OR TOPPING SURFACES = LIGHT BROOM FINISH W/ STRIA OF %6" FORMED SURFACES = SMOOTH FORM FINISH SURFACES RECEIVING GROUT = SCRATCH FINISH 16. CONCRETE CURING: MOIST CURE CONCRETE SURFACES OR USE AN APPROVED CURING MEMBRANE IN ACCORDANCE WITH ACI 301 UNLESS A LONGER TIME IS REQUIRED IN THE SPECIFICATIONS. 17. CONCRETE DEFECTS: REPAIR FORMED SURFACES BY REMOVING MINOR HONEYCOMBS, PITS GREATER THAN 1/2-SQUARE-INCH IN AREA OR GREATER THAN 1/4-INCH IN DEPTH, AND ALL OTHER DEFECTS AS DIRECTED BY THE CITY OR AS DESCRIBED IN THE SPECIFICATIONS OR REFERENCE DOCUMENTS. PROVIDE EDGES PERPENDICULAR TO THE SURFACE, PATCH WITH GROUT AS SPECIFIED ABOVE, AND PROVIDE A SMOOTH FORM FINISH. CONCRETE WITH EXTENSIVE HONEYCOMBING OR OTHER DEFECTS WHICH AFFECT SERVICEABILITY AND/OR STRUCTURAL STRENGTH OF THE CONCRETE ELEMENT, AS DETERMINED BY THE CITY, SHALL BE REJECTED AND REPLACED AT NO ADDITIONAL COST TO THE CITY. METAL GRATING 1. METAL GRATING SHALL BE HOT DIPPED GALVANIZED STEEL TO ASTM A 123, ADA COMPLIANT AND SUPPORT A LIVE LOAD OF 90 PSF, OR A POINT LOAD OF 8,000 LBS ON ONE SQUARE FOOT. 2. BEARING BARS SHALL BE 2 INCH HIGH BY 3/16 INCH THICK SPACED AT 1/2 INCH OC. 3. TRANSVERSE BARS SHALL BE SPACED AT 4 INCHES OC. 4. METAL GRATING SHALL BE SHOP FABRICATED BASED ON AS -BUILT STRUCTURE DIMENSIONS (FIELD CUTTING IS NOT ALLOWED). 5. HOT -DIP GALVANIZE AND APPLY NON-SKID FINISH TO GRATING AFTER FABRICATION. 6. METAL GRATING SHALL BE SHOP FABRICATED BASED ON AS -BUILT STRUCTURE DIMENSIONS (FIELD CUTTING IS NOT ALLOWED). 7. METAL GRATING FASTENERS SHALL BE MECHANICAL FASTENERS PER THE GRATING MANUFACTURER, MEETING ADA REQUIREMENTS. 8. MAXIMUM SPACING OF THE METAL GRATING FASTENERS WILL BE DETERMINED BY THE GRATING MANUFACTURER. STRUCTURAL SPECIAL INSPECTION 1. TESTING AND SPECIAL INSPECTION SHALL BE PER THE TABLES ON SHEET 1A AS REQUIRED PER THE IBC AND AISC 360-16, AND AS REQUIRED IN THE SPECIFICATIONS. GDN 2/9/22 GDN SURVEYED: SCALE: GDN 8/11/22 GDN DESIGNED: GDN DRAWN: AHK CHECKED: CS13 BY DATE AP P R APPROVED: GDN 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY R-420224 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT STRUCTURAL NOTES 10/26/23 FIEW130OK: FB PAGE` PAGE DRAWING NO: S-1 SHEET: OF: 28 45 O O CD O T N a J M C'7 O O O T O 0 LLI NOTE: FRP LUMBER CLADDING NOT SHOWN, SEE LANDSCAPE DRAWINGS FOR CLADDING LAYOUT Q N O� co N CD N N U 0 C O O� LO LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE LICENSED ENGINEER OR LANDSCAPE ARCHITECT. c� J WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 "A KIPll7All IKI/^ NO. 'InCI Oil nu.., 5 0 5 10 1" = 5' scale feet r-% i 1 \ V/\ I v l L � 1 r-% %.. L V I ELEVATION - REPLACEMENT BRIDGE SCALE: REVISION 5 0 5 10 1"=5' scale feet SURVEYED: SCALE: DESIGNED: 1 "=20' � GDN + DRAWN: AHK ONE INCH CHECKED: AT FULL SCALE CSB IF NOT ONE INCH BY DATE AP P R APPROVED: GDN SCALE ACCORDINGLY CITY OF RENTON R-420226 IN COMPLIANCE WITH CITY OF RENTON STANDARDS GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT BRIDGE PLAN & ELEVATIONS 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: S-2 30 45 N O O O O T a J C'7 C'7 O O O O T O Cm OHW cm W �ONv� �0 N, CL ABUTMENT 2 PILES `LBRIDGE & 7'-011 �EARI NG 71-011 CLBEARING 1 5'-4 1/2" N 00 rn N U V NOTE: FOR REINFORCEMENT DETAILS SEE A Q CID N 5-10 co N O N N 1 rA o - SCALE: 2 0 2 4 1/211 = 1'-01 0 scale feet Ln RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED >, IN PART ON INFORMATION PROVIDED BY OTHERS. -0 CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE in LICENSED ENGINEER OR LANDSCAPE ARCHITECT. J 5'-4 1/2" BEARING ELEVATION - CONC ABUTMENT WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 CL BRIDGE FOUNDATION PLAN SCALE: 4 0 4 8 1/411 = 1'-011 scale feet MATCH ACP TRAIL SLOPE, SEE CIVIL DRAWIP ACP TRAIL CONC BACKWALL 1 SEE - FOI PAVEMENT SE) BLOCKOUT FOR ELECTRICAL BLOCKOUT FOR WL x 1/2" STEEL PILE, TYP 1 1 RECORD DRAWING GRAVEL FOR WAI G nii r WORK POINT COORDINATES WP EASTING NORTHING W P 1 1301827.3032 189361.2657 W P2 1301793.2818 189457.1240 VALL in,, E BEARING U O' F—� NOTE: B FOR ALL DETAILS NOT SHOWN SEE CONC PILE CAP - DETAIL - PAVEMENT SEAT 'TIONAL CJ EL PILE SECTION - CONC ABUTMENT SCALE: 2 0 2 4 1/211 — 1'-011 scale feet GDN 10/26/23 GDN SURVEYED: SCALE: 1 "=20' CITY OF DESIGNED: GDN + RENTON DRAWN: --CHECKED,,__ AHK ONE INCH C AT FULL SCALE IF NOT ONE INCH REVISION BY DATE APPR SCALE ACCORDINGLY APPROVED: GDN SCALE: 1 0 1 2 1" = 1'-011 scale feet R-420227 IN COMPLIANCE WITH CITY OF RENTON STANDARDS GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT FOUNDATION PLAN AND SECTIONS LO LO 0 Qo N Q U W N O 0 O O T N a J 10/26/23 RELDBOOK: FB PAGE` PAGE DRAWING NO: S-3 SHEET. 31 OF. 45 co co O O O 0 T N 1 O I 0 W I B I S-6 A SYM ' S-6 (-L BRIDGE (L END DIAPHRAGM (L- DIAPHRAGM (L- DIAPHRAGM CL DIAPHRAGM (L- DIAPHRAGM (L DIAPHRAGM 21'-1 1/4" 21'-9 3/4" 4'-7 1/2" 6' -211 4'-7 1/2" 7 A SEE S 8 OPP, TYP B C STEEL GIRDER 3 � GRATING SUPPORT 1 @ 2'-0" MAX SP, TYP 21'-9 3/4" CL DIAPHRAGM 21'-1 1/4" CONC ABUTMENT, TYP ,4fSEE S 9 TYP ----------` (L END DIAPHRAGM I I STEEL GIRDER 2 I I l 1 GRATING SPAN DIRECTION, TYP - - STEEL - GIRDER 1 SEE 8 TYP - --- --- ---- I I I I I SEE 7 TYP S-$ 42'-3 1/2" I I OVERLOOK FRAMING, SEE ( b7"" 4'-4 1/2" 8'-0 3/4" ------------� I N \ I � I I 4'-4 1/2" 42'-3 1/2" 101'-5 1/4" NOTES: A FOR GIRDER CAMBER REQUIREMENTS SEE S-5 SEE S $ TYP SEE 8 TYP SEE Q18') TYP C8x18.75, TYP 00 • U 00 U — - BOT OF FLA GE N CONC ABUTMENT STEEL PILE, TYP LO LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE LICENSED ENGINEER OR LANDSCAPE ARCHITECT. in c� J R N rl N SEE S $ SIM GIRDER STOP, TYP CONC BRIDGE END SLAB 00 SECTION - END DIAPHRAGM SCALE: 2 0 2 4 6" = 1'-0" mommoll scale inches WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 END TO END STEEL GIRDER PLAN - BRIDGE FRAMING SCALE: 4 0 4 8 1" = 4' scale feet SEE (i)T QL") YPYP 5 SEE TYP SEE S $ TYP GRATED DECKING C8x18.75, TYP 00 U -— `� 1000 75, — -- — � m -- 00 V o 0 N _ [=jLpo 000 -------- 000 — — — — — — �" 8" WATERMAIN LO STEEL GIRDER, TYP STEEL GIRD`ER,YP 1 1 RECORD DRAWING NOTE: A FOR DETAILS NOT SHOWN SEE �SECTION - DIAPHRAGM 2 0 2 4 6" = 1'-0" mommoll scale inches GDN 0/26/2 GDN SURVEYED: DESIGNED: GDN DRAWN: AHK CHECKED: CSB REVISION BY DATE APPR APPROVED: GDN CONC TOPPING, TYP EXTERIOR OVERLOOK BEAM r-c`� SECTION 0 Vvm I LI\IVIMIlm STEEL GIRDER, TYP - DIAPHRAGM w 0 I w � o 0 Ln m N I w in CONC TOPPING, TYP NOTE: B FOR DETAILS NOT SHOWN SEE _..__. 2 0 2 4 6" = 1'-0" scale inches R-4420227 SCALE: 1 "=20' CITY OF RENTON ONE INCH AT FULL SCALE • IF NOT ONE INCH SCALE ACCORDINGLY IN COMPLIANCE WITH CITY OF RENTON STANDARDS GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT FRAMING PLAN I� L0 N LO C:) F� O F-I N Q U O V W N 0 0 0 I T a J 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: S-4 SHEET: OF: 32 45 C'7 O O C:) T O Nt N 0 W I EXPANSION JOINT, SEE 2 TYP — 5-12 EXPANSION JOINT, SEE 2 TYP — S-12 a oc J 2" CLR N ri r-I 3/4" CHAMFER, TYP -3 PL 1/2 CL ABUTMENT �i PILES END SLAB 5'-8 1/4" 3", TYP I 1/2"0 WELDED STUDS @8"OC END DIAPHRAGM, TYP Cl 0 (L- ABUTMENT PILES END SLAB 5'-8 1/4" 3", TYP I 1/2"0 WELDED STUDS @ 8" OC MAX GRATING SUPPORT SPACING FROM END OF GRATING IS 6", TYP I I END DIAPHRAGM E SEE 1 TYP GRATING SUPPORT, TYP GRATING SUPPORT, TYP CONC TOPPING ELEVATION - EXTERIOR GIRDER SCALE: 1/2"=1'-0" 2 0 2 4 1/2" = 1'-0" scale feet METAL GRATING ELEVATION - INTERIOR GIRDER SCALE: 1/2"=1'-0" 2 0 2 4 1/2" = 1'-0" scale feet GIRDER GIRDER HANDRAIL BASE PL, SEE LANDSCAPE HANDRAIL BASE PL, SEE LANDSCAPE DRAWINGS FOR LOCATION, SEE S-12 DRAWINGS FOR LOCATION, SEE S-12 FOR DETAILS 2" CLR FOR DETAILS 3/4" CHAMFER, TYP 3" , I (3) #4 CONT BARS, EQ SPA 3/4" CHAI #3@4"OC 3" 3" CONIC BRIDGE END SLAB 3" 3" 1/2"x2" WELDED STUD, TYP I PL 1/2 1/2"x2" WELDED STUD, TYP M N O N N TYP 3/8 W36x160 U 0 rC SECTION -EXTERIOR GIRDER � - SCALE: 1" " =1'-0 Ln RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED >, IN PART ON INFORMATION PROVIDED BY OTHERS. -0 CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE in LICENSED ENGINEER OR LANDSCAPE ARCHITECT. J GIRDER a � I J #3 @ 4" OC CONIC END SLAB '2"x2" WELDED STUD, TYP (L ABUTMENT END SLAB PILES 5'-8 1/4" CL ABUTMENT END SLAB PILES 5'-8 1/4" CJ P STEEL GRATING GIRDER DETAIL -GIRDER DAP R-420230 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TYP 3/8 W36x160 TYP 3/8 � W36x160 TYP 3/8 W36x160 1 SECTION -EXTERIOR GIRDER K`­E� SECTION � SE - INTERIOR GIRDER % SCALE:1"=1'-0" WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 D. N4 wAs��� R-6 O✓ �� FGISTER� ss10NAL E�� o�� N 0. n6 % SCALE:1"=1'-0" REVISION - INTERIOR GIRDER SURVEYED: DESIGNED: GDN DRAWN: AHK CHECKED: CSB BY DATE APPR APPROVED: GDN O N N Ln O F� O F-I N Q U W N 0 0 O T a J co SALE. DAM 10/26/23 1 "=20' CITY OF GENE COULON MEMORIAL BEACH PARK � FlELDBOOK: FB � RENTON TRESTLE BRIDGE REPLACEMENT PAGE` PAGE ONE INCH ' DRAWING N0: AT FULL SCALE GIRDER ELEVATION &SECTIONS S- 6 IF NOT ONE INCH SCALE ACCORDINGLY SHEET: OF: 34 45 co O O O T r DDInr-c nIADUDAr-nn TVA O 0 W NOTES: PLAN -OVERLOOK FRAMING 1. WELDED STUDS NOT SHOWN 2. STEEL GRATING NOT SHOWN SCALE: 3/4"=V-0" — HANDRAIL BASE PL, SEE LANDSCAPE DRAWINGS FOR LOCATION, SEE S-12 FOR DETAILS DAPPED BEAM END, SEE STEEL GRATING, TYP L3X3, GRATING SUPPORT 1 3/4" EXTERIOR OVERLOOK BEAM INTERIOR OVERLOOK BEAM < M O� M N CD CJ P 21-10"—�--� SI STIFFFENER PL 3/8" CENTERED ON OVERLOOK BEAM CJ P N A SECTION -OVERLOOK FRAMING o - SCALE: 1 1/2"=V-0" 8 0 8 16 1-1/2" = 1'-0" ° scale inches LO RECORD DRAWING co THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE LICENSED ENGINEER OR LANDSCAPE ARCHITECT. U) c� J WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 1 0 1 2 3/4" = 1'-0" scale feet CL GIRDER I _ CONC TOPPING 1 1 REVISION 1 2" CL #4 CONIC CAP REINF #4 1'-0" IN LAP SPLIC ------------------------------ -- 3�� 1/2"0 WELDED STUDS @ 8" OC 3�� — 3/4" CHAMFER, TYP EXTERIOR OVERLOOK BEAM 3" GIRDER t CJ P EXTERIOR STEEL GIRDER STIFFFENER PL 1/2" CENTERED ON OVERLOOK BEAM ELEVATION - OVERLOOK (-L GIRDER HANDRAIL BASE PL, SEE LANDSCAPE DRAWINGS 1'-3" FOR LOCATION, SEE S-12 FOR DETAILS, TYP I LO N LO O F� O — — — — — — — F—I N ' QooQQo Qv 000 � O00 10 W SPLICED #4 UNDER CONIC CAP REINF N O O O — O 000 N Sc.tiLt: 1 1/L..=1 -u 8 0 8 16 1-1/2" = 1'-0" scale inches INTERIOR OVERLOOK BEAM EXTERIOR STEEL GIRDER DETAIL - DAPPED INTERIOR BEAM HANDRAIL BASE PL, SEE DRAWING S-12 SIM DIAPHRAGM EXTERIOR STEEL GIRDER REVISION 1/2"Ox2" HEADED STUD, TYP • PL 3/8 SCALE: 1 1/2"=V-0" 8 0 8 16 1-1/2" = 1'-0" scale inches 1/4 (L BEAM MECHANICAL STEEL GRATING FASTENER � CONC TOPPING 3/8" MAX STEEL GRATING MECHANICAL STEEL GRATING FASTENER — L5x3x3/8 5/16 TYP 3/8 HP12x53 SECTION - EXTERIOR OVERLOOK BEAM SCALE: 1 1/2"=V-0" 8 0 8 16 1-1/2" = 1'-0" scale inches GDN 8/11/22 GDN SURVEYED: DESIGNED: GDN DRAWN: AHK CHECKED: CS13 BY DATE AP P R APPROVED: GDN SCALE: 1 "=20' ONE INCH AT FULL SCALE • IF NOT ONE INCH SCALE ACCORDINGLY L3x3x3/8 BEAM METAL GRATING PL 3/8 3 SIDES 1 TYP 3/8 — HP12x53 SEC O - TERIOR OVERLOOK BEAM SCALE: 1 1/2"=V-0" 8 0 8 16 1-1/2" = 1'-0" scale inches R-420231 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT OVERLOOK PLAN ELEVATION &SECTIONS 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: S-7 SHEET: OF: 35 45 C'7 O O O O T li= O N 0 W CONIC END SLAB BOLT 1"0 W/ WASHER, TYP II �� 3 'i-' 3 1/4" C8 I I I m m NOTES: L - 1. SLOT GIRDER PL 1/2 AND I U) WELD DIAPHRAGM PL 1/2 00 1 TO W36 STEEL GIRDER I m E N I - - - 2. MAXIMUM GAP BETWEEN ----- L3x3x3/8 Q CHANNEL AND GIRDER IS _ — — — —_— 1/411 -t-- - _ — Q r- L �- CL IRDER 1/4 1/4 8 3/4" I r-I CIO BOL 3/4"0 W/ WASHER 3: PLASTIC LUMBER FACING 1 3/8" O STEEL GIRDER 1 3 2 1/4" /8" �L o DIAPHRAGM PL 1/2" U CJ P DETAIL -DIAPHRAGM CONNECTION 1 SCALE: 2"=1'-0" DIAPHRAGM PL 1/2" STEEL GIRDER PLASTIC LUMBER FACING 2 1/4" 3" 3" NOTE: 10" 00 \ FOR DETAILS NOT SHOWN SEE 1 CJP C8x18.75 -L 3/4" BOLT W/ WASHER, TYP DETAIL - DIAPHRAGM CONNECTION 3 SCALE: 2"=1'-0" CONIC T( NOTE: MAXIMUM GAP BETWEEN CHANNEL AND GIRDER IS 1 Q 5/16 CID PLASTIC LUMBER FACING o� co N o STEEL GIRDER DETAIL -GRATING SUPPORT C N 7 0 S-4 SCALE:2"=1'-0" 0 rn 0 RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. WSP USA Inc. 33301 9th Avenue South CHANGES SHOWN HAVE BEEN PROVIDED BY THE Suite 300 Federal) Way, WA 98003-2600 > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE TEL: (206) 431-2300 c`n° LICENSED ENGINEER OR LANDSCAPE ARCHITECT. FAX: (206) 431-2250 c� J DIAPHRAGM PL 1/2", TYP 3/4"0 BOLT W/ WASHER, TYP L3x3x3/8, TYP oo CL GIRDER (SYM) CJ P, TYP I C8x18.75, TYP 1"0 BOLT W/ WASHER, TYP NOTE: FOR DETAILS NOT SHOWN SEE 1 r DETAIL - DIAPH R 21, 8 1/4" 1 3/4" 00 N \ m r - �o 00 `° ---- AGM CONNECTION 2 S-4 SCALE:2"=1'-0" CL BOLT 1"0 W/ WASHER, TYP CONIC TOPPING IRDER 2 1/4„ STEEL GRATING 61/2" 311 311 00 - \ \ I m I --I-- I N � I 00 N Lr) --- 0 ---��� — ----- C8x18.75 \ � L3x3x3/8 CJ P PLASTIC LUMBER FACING STEEL GIRDER DIAPHRAGM PL 1/2" - r DETAIL - BOLT 3/4"0 W/ WASHER, TYP — STEEL GRATING \ m f V N 8x18.75 m -6" ONNECTION D. NF wasH1 %-, 1 RECORD DRAWING � � sus �✓ °r FCISTV, ssloNAL Eo�� NO. / 13/g„ 131 8 1/4" DIAPHRAGM C SCALE: 2"=1'-0" STEEL GRATING PL 1/2x6x0'-6", TYP NOTE: Op Op MAXIMUM GAP BETWEEN Op Op CHANNEL AND GIRDER IS 1/4I1 / TYIL P 6 C8x18.75, TYP 5/15/16 STEEL INTERIOR GIRDER REVISION BOLT 3/4"0 W/ WASHER 1 3/4" INECTION 4 GIRDER (SYKM 1/2" I 311 STEEL GRATING 1'-4 1/8" C8x18.75, TYP DIAPHRAGM PL 1/2", TYP STEEL INTERIOR GIRDER CL GIRDER (SYM) 3" 3" LO M N LO r-I O F� O N U rn I O 3/4" BOLT W/ WASHER, TYP ETA I CJ P, TY P N DETAIL - DIAPHRAGM SCALE: 2"=1'-0" NOTE: O FOR DETAILS NOT SHOWN SEE 1 O _ O T SUPPORT CONNECTION 3 a STEEL GIRDER CL GIRDER DIAPHRAGM PL 1/2", TYP (SYM) 3/4"0 BOLT W/ WASHER, TYP 1 8 1/4" 1 3/4" L3x3x3/8, TYP � I (00 M ---------, I C8x18.75, TYP 1"0 BOLT W/ WASHER, TYP NOTE: — 8 3/4" TI TI rn FOR DETAILS NOT SHOWN SEE 1 DETAIL - DIAPHRAGM CONNECTION 5 \ m I � N N \ m m 3/4" BOLT W/ WASHER, TYP DETAIL - GRATING SUPPORT CONNECTION SCALE: 2"=1'-0" GDN 10/26/2 GDN SURVEYED: DESIGNED: GDN DRAWN: AHK CHECKED: CS13 BY DATE AP P R APPROVED: GDN SCALE: 2"=1'-0" SCALE: 1 "=20' CITY OF �+ RENTON ONE INCH AT FULL SCALE • IF NOT ONE INCH SCALE ACCORDINGLY BO 00 \ Ln 0 00 \ R-420232 IN COMPLIANCE WITH CITY OF RENTON STANDARDS GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT SECTIONS & DETAILS - SHEET 1 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: S-8 SHEET. 36 OF. 45 FO co m O O O T N O I 0 W CL C8 4'-0" MAX C8 A 00 U L=0 00 U 00 U 00 U L VLJL VI LJ 11\V LI\ NOTE: GRATING NOT SHOWN METAL BAR GRATING o� LO LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE LICENSED ENGINEER OR LANDSCAPE ARCHITECT. c� J J J PLAN - GRATING SUPPORT /''gDERI TYP SCALE: 3/4"=1'-0" 2 0 2 4 3/411 = 1'-011 scale feet C8, TYP 1 1/2" BOLT 3/4"0 W/ WASHER, TYP L 1/4" MAX, TYP SECTION - GRATING SUPPORTS SCALE: 2"=1'-0" 6 0 6 12 2" = 1'-011 --k � scale A, �A- --.A, inches WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 D. 1V� 4 0� wasH1 6✓ o"�ss soNAL F��'���p�'��� N 0. RECORD DRAWING SEE 8 TYP :8, GRATING SUPPORT, TYP GRATING SPAN DIRECTION, TYP REVISION 00 L--I.j - � J SEE 8 TYP 00 U US— C8x18.75, TYP GRATED DECKING J I LLL V 11\VLI\, 1 1 1 PLAN - SECTION AT DIAPHRAGMS CONC TOPPING, TYP NOTE: FOR DETAILS NOT SHOWN SEE B S-4 8" WATERMAIN SCALE: 3/4"=1'-0" 2 0 2 4 3/411 = 1'-011 scale feet GRATED DECKING J I LLL V11\VLI\, 1 1 1 8" WATERMAIN PLAN - SECTION AT GRATING SUPPORT CHANELS SCALE: 3/4"=1'-0" 2 0 2 4 3/411 = 1'-011 scale feet GDN 10/26/2 GDN SURVEYED: DESIGNED: GDN DRAWN: AHK CHECKED: CSB BY DATE AP P R APPROVED: GDN SCALE: 1 "=20' ONE INCH AT FULL SCALE • IF NOT ONE INCH SCALE ACCORDINGLY CONC TOPPING, TYP R-420233 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT SECTIONS &DETAILS -SHEET 2 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: S-9 SHEET: OF: 37 45 N O C:) C:) C:) T a J C'7 C'7 O O 0 I T N 0- END GIRDER STOP, SEE 10-#8 HEADEC DOWELS, SEE COORDINATE STIRRU LONGITUDINAL BAR L CONNECTION TO AVC Q 00 co N O N 1 DETAIL - PILE C 0 - SCALE:3/4"=1'-0" 0 'tBRIDGE & BEARING ( YM) nrT\A/rrKI f"Inr%rn cTrinC' nrf-rcc, f`rinlf` Plrl\A/NI ill rrin \A/1 ELEVATION - ABUTMENT REINFORCMENT SCALE: 3/4"=1'-0" rn L0 RECORD DRAWING co THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE c`n° LICENSED ENGINEER OR LANDSCAPE ARCHITECT. U) ca J r-lnnrn cTr�n PILE CUT-OFF ELEV ONNECTION WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 Q NO. REVISION 1 RECORD DRAWING REVISION CONIC BACKWALL N r-I O m END GIRDER STOP, SEE S 11 SIM )R PILE CONNECTION DETAILS, SEE 1 TYP ILE, TYP CL PILE #5@8"0( PAVEMENT SEAT #5 BACK STIRRUP FOR PILE CONNECTION DETAILS COORDINATE STIRRUP & LONGITUDI W/ PILE CONNECTION TO AVOID INTI �LUa LU Lil = N LU ul LU LUU IL = i ILL 0 O O #8 HEADED BAR. SPACE AROUND INSIDE OF PILE TO AVOID INTERFERENCE W/LONGITUDINAL & TRANSVERSE REINFORCEMENT (10 BARS EA PILE) TOUCH UP PILE COATING AFTER WELDING (SEE SPECIFICATIONS) I I GDN 8/11/22 GDN SURVEYED: GDN 0/26/2 GDN DESIGNED: GDN DRAWN: AHK CHECKED: CS13 BY DATE AP P R APPROVED: GDN f"fl Alf` 17)Af`1/1A/AI I E BEARING ALTERNATE ENDS PILE CAP STIRRUPS @ 8" OC 1*8 SECTION - ABUTMENT REINFORCEMENT SCALE: 3/4"=V-0" (5/16) (5/16) m FI F\/ATinN DETAIL - PILE CONNECTION SCALE: 1"=1'-0" SCALE: 1 "=20' �+ ONE INCH 0AT FULL SCALE • IF NOT ONE INCH SCALE ACCORDINGLY NOTE: COAT ALL PILING IN ACCORDANCE WITH THE SPECIFICATIONS. COATING SHALL EXTEND FROM CUT-OFF TO 15' BELOW MUDLINE. SUBMIT PILE ORDER/COATING LIST TO CITY FOR APPROVAL. CITY OF RENTON R-420234 IN COMPLIANCE WITH CITY OF RENTON STANDARDS GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT SECTIONS & DETAILS - SHEET 3 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: S-10 38 45 N O O O T a J co C'7 O O O O T Er n O 0 W m L m m ry Q (3 C Q G7 D I U) O 0 U Q co CD SECTION -GIRDER STOP CIA (2) #5 x5'. OF OPENI CENTER C EA FACE) WATER N DRAWIN( 1 #5 LONG, TYP BACKWALL STIRRUP ONG BAR, TYP SACKWALL STIRRUP, TYP STOP BACKWALL STIRRUPS & LONG BARS 2" CLR AT INTERFERENCE W/ BLOCKOUT PILE CAP STIRRUPS )ILE CAP LONG BAR DETAIL - UTILITY BLOCKOUT SCALE: 1 0 1 2 1" = 1'-0" scale feet /`!lKIr DA/`I/%A/A1 1 N 5-10 SCALE: g 0 8 16 0 1-1/211 = 1'-011 o scale inches LO LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE c`n° LICENSED ENGINEER OR LANDSCAPE ARCHITECT. U) cU J WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 GIRDER STOP — #5 n HAIRPINS #5 �P LONG BAR, TYP E CAP STIRRUP Q NO. REVISION 1 RECORD DRAWING REVISION DETAIL - END GIRDER STOP SCALE: 8 0 8 16 1-1/211 = 1'-011 scale inches 8" MIN CONIC GIRDER STOP EMBED m m n OPTIONAL Q COUPLE NUT TACK WELD TO PL SECTION GDN 8/11/22 GDN SURVEYED: GDN 0/26/2 GDN DESIGNED: GDN DRAWN: AHK CHECKED: CS13 BY DATE AP P R APPROVED: GDN OPTIONAL PILE CAP LO PILE CAF 3/4"0 BOLT, TYP 3"0 COUNTERBORE, TYP 3/4" CHAMFER, TYP PL 1/2x10x1'-6" 01 1 / 4 \ DETAIL - CENTER GIRDER STOP SCALE: 8 0 8 16 1-1/211 = 1'-011 scale inches DETAIL - GIRDER STOP PAD SCALE: 4 0 4 8 2" = 1'-011 scale inches SCALE: 1 "=20' �+ ONE INCH 0AT FULL SCALE • IF NOT ONE INCH SCALE ACCORDINGLY IRDER STOP CI C\/ATI/lAl EQ SPA, TYP DER STOP, TYP #5, TYP R-420235 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT SECTIONS &DETAILS -SHEET 4 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: S-11 SHEET: OF: 39 45 N O O O T a J co C0 CD O O C T CV O 0 W CONC CAP 2"0 SS ROUND POSTS RAIL SUPPORTS, TYP 3/8"0 SS TAMPER -RESISTANT BUTTON HEAD TORX SCREW W/ WASHER, TYP N NOTE: FOR ALL DETAILS NOT SHOWN SEE LANDSCAPE DRAWINGS DETAIL - STAINLESS STEEL END POST RAIL BASE PLATE SCALE: 3"=1'-0" SS 3/8" HEAVY HEX BOLT W/ WASHER, TYP SS 3/8" COUPLE NUT, TYP 3/4" CHAMFER, TYP i I SS RAIL SUPPORT SS TAMPER -RESISTANT BUTTON HEAD TORX SCREW W/ WASHER, TYP SS BASE PL 2" CLR, TYP (3) #4, EQ SPA A CONIC CAP - SS PL 3/8" � �1 1 1/2" Tyo I 2"0 SS ROUND POSTS RAIL SUPPORTS, TYP 3/8"0 SS TAMPER -RESISTANT BUTTON HEAD TORX SCREW W/ WASHER, TYP fV SS WEBNET FRAME HOLDER WITH VANDAL RESISTANT CAPS - - I I N M I I N WEB NET PANEL, TYP - 3„ 311 M TYP 5/16 3" 1 1/2" NOTE: -..Mgj FOR ALL DETAILS NOT SHOWN SEE LANDSCAPE DRAWINGS 1/2"0 X 2" HEADED STUD @ 8" OC, TYP STEEL GIRDER SECTION - CONC CAP & SS RAIL BASE PL Q - SCALE:3"=1'-0" 0 0 r co N CD N N U 0 C O O� LO LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE c`n° LICENSED ENGINEER OR LANDSCAPE ARCHITECT. in c� J WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 DETAIL - STAINLESS STEELTWO POST RAIL BASE PLATE SCALE: 3"=1'-0" 1 1 RFI 09 HAND RAIL MISC DETAILS — CLARIFICATIONS AND MODIFICATIONS NO. REVISION DEW 7/6/22 1 GDN SURVEYED: DESIGNED: GDN DRAWN: AHK CHECKED: CSB BY DATE AP P R k PROVED: GDN WEB NE SCALE: 1 "=20' ONE INCH AT FULL SCALE • IF NOT ONE INCH SCALE ACCORDINGLY JPPORT PER -RESISTANT TORX SCREW -YP DETAIL - STAINLESS STEEL MID RAIL BASE PLATE SCALE: 3"=1'-0" R-420237 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CITY OF GENE COULON MEMORIAL BEACH PARK RENTON TRESTLE BRIDGE REPLACEMENT SECTIONS &DETAILS -SHEET 6 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: S-13 SHEET. 41 OF, 45 N O C:) O T a J C'7 C'7 O O O O T n O 0 W SCALE: 3/4"=1'-0" V-3 3/4" EQ PIPE OD + 1/4" EQ rB I I PL 1/2 I I I I I � I 3/4"0 EPDXY I I I I ANCHOR, TYP -E3- P L 1/2 U ai i.i Q N 0 0 co 1 DETAIL — PIPE BRACKET o - SCALE:3"=V-0" N U 0 C O O� LO LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE LICENSED ENGINEER OR LANDSCAPE ARCHITECT. c� J ABUTMENT PILE nl Anun A!- RA 1 0 1 2 3/4" = 1'-0" scale feet MATCH FLANGE BOLT SPA & DIA 211 TYP WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 SEE 2 1" SECTION — PIPE BRACKET SCALE: 3"=1'-0" NO. STEEL GIRDER REVISION > R, T` m PIPE I AV I FlkI(,TI-I DECKING GRATING SUPPORT, TYP WATERLINE PIPE SUPPORT NOTES: 1. COORDINATE WITH GUIDED PIPE SUPPORT MANUFACTURER, INSULATED PIPE MANUFACTURE AND ADJUST THE ELEVATION OF THE C6 FOR THE PIPE TO PASS THROUGH THE DIAPHRAGMS. D PIPE 2. RESTRAINED PIPE SUPPORT IS A PIPE SHIELD MODEL B 4200 GUIDED INSULATED PIPE SUPPORT (WWW.PIPESHIELDS.COM), OR ENGINEER APPROVED EQUAL. =RIOR GIRDER BEYOND 3. MAXIMUM GAP WIDTH BETWEEN GIRDER AND C6 SHALL BE 1/4" ELEVATION — WATERLINE PIPE SUPPORT SCALE: 3/4"=1'-0" 1 1/ L 1 1/ L 1 0 1 2 3/4" = 1'-0" scale feet SECTION - PIPE SUPPORT SCALE: SURVEYED: DESIGNED: GDN DRAWN: AHK CHECKED: CSB BY DATE AP P R APPROVED: GDN SCALE: 1 "=20' ONE INCH AT FULL SCALE • IF NOT ONE INCH SCALE ACCORDINGLY CITY OF RENTON 'PORT M110% DETAIL —PIPE SUPPORT SCALE: R-420238 IN COMPLIANCE WITH CITY OF RENTON STANDARDS GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT UTILITY SUPPORT - SECTIONS AND DETAILS 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: S-14 42 45 N O O O O T a J m C'7 O O O O T n unr — O W I— L ry U) Q U Q U) D I O 0 U WE N 0 SCALE: 0 LO LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE LICENSED ENGINEER OR LANDSCAPE ARCHITECT. c� J —OHP— _ — -H p- - —21 n �I oaf MENEM Mon momom MEMEN _ 21 GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT LAKE WASHINGTON RENTON SAILING CLUB DOCK PLAN - ROSE WALL BULKHEAD REPAIR SCALE: 30 0 30 60 1" = 30' scale feet CV ICT TI I\An Cn A V 0 T/ln nllA nrl EXIST TIMBER 8X8 POST 1 1 1 ELEVATION - ROSE WALL BULKHEAD XISTTIMBER 4X8 LAGGING BOARD, TYP APPROX GROUND EL BEHIND BULKHEAD APPROX GROUND EL IN FRONT OF BULKHEAD REPAIR 1 0 1 2 1"=1' scale feet WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 APPRC BEHIN 4*OPF17 \^k+ 0 EXIST PARK TRAIL EXIST TIMBER ROSE WALL BULKHEAD SEE 1 cvlcT Tlnnncn ^.X8 TOP BOARD TIMBER 4X8 LAGGING BOARD, TYP ENTERED ON POST 'PROX GROUND EL IN ,ONT OF BULKHEAD SECTION - ROSE WALL BULKHEAD REPAIR SCALE: 1 0 1 2 1"=1' scale feet SURVEYED: SCALE: DESIGNED: 1 "=20' CITY OF GDN + AHK DRAWN: RENTON ONE INCH CHECKED: AT FULL SCALE CSB IF NOT ONE INCH NO. REVISION BY DATE AP P R APPROVED: GDN SCALE ACCORDINGLY R-420239 IN COMPLIANCE WITH CITY OF RENTON STANDARDS GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT ROSE WALL REPAIR z 3 Q 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: S-15 43 45 '1 r^_' VrA/' L/ C:) T U N O O O O T a J C'7 C'7 O O O O T N N O N 0 W m U) (1) IY U) Q U Q C0 a O Q 0 U r` M CV co cli O AdN CROSS ENGINEERS, INC r; 923 MILK Jr. Way Phone: (253) 759-0118 O . Tacoma, WA 98405 Job Number: 20-008 z info@crossengineers.com O RECORD DRAWING 0 THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE c/) LICENSED ENGINEER OR LANDSCAPE ARCHITECT. Z) _J WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 EXISTING BRIDGE DEMO ELECTRICAL PLAN SCALE: 1" = 5-0" ENL•y 0029060 /STERF'� ss�ONAL N0. RECORD DRAWINGS G11aY16`1IM101 GRAPHIC SCALE 5 0 5 10 1 "=5'-0" scale feet SJK h 1 /17/23 SLH ' SURVEYED: DESIGNED: GLW DRAWN: JAE CHECKED: GLW BY DATE APPR APPROVES SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY GENERAL NOTES: 1. ELECTRICAL REQUIREMENTS ARE NOT LIMITED TO ELECTRICAL DRAWINGS. THERE IS ADDITIONAL ELECTRICAL WORK REQUIRED TO BE INCLUDED IN THE BID, INDICATED ON STRUCTURAL AND CIVIL DRAWINGS AND IN THE SPECIFICATIONS. CONTRACTOR SHALL REVIEW ALL DRAWINGS, SPECIFICATIONS AND INCLUDE COSTS FOR ELECTRICAL WORK IN THE BID. 2. CONTRACTOR SHALL REVIEW AND COORDINATE ALL TRENCHING WITH BRIDGE CONCRETE ABUTMENT CONSTRUCTION. CONDUIT SLEEVES ARE PROVIDED IN CONCRETE ABUTMENT FOR ELECTRICAL. 3. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION BY CALLING THE UNDERGROUND LOCATE LINE AT 1-(800)-424-5555 A MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATION. THE CONTRACTOR WILL ALSO BE RESPONSIBLE FOR MAINTAINING ALL LOCATE MARKS ONCE THE UTILITIES HAVE BEEN LOCATED. 4. CONTRACTOR SHALL OBTAIN AND PAY FOR PROJECT ELECTRICAL PERMIT WITH AUTHORITY HAVING JURISDICTION (AHJ). ALL WORK SHALL COMPLY WITH CURRENT NATIONAL ELECTRICAL CODE AND WASHINGTON ADMINISTRATIVE CODE. 5. HAND DIGGING WILL BE REQUIRED. ALL CONDUITS SHALL BE BEDDED 3" MINIMUM ALL SIDES, IN CLEAN FREE FLOWING, COURSE GRADE SAND AS DEFINED IN ASTM D 2487. COMPACT TO 95%. PROVIDE ELECTRICAL WARNING TAPE 12" BELOW FINISHED GRADE OVER CONDUITS. ELECTRICAL NOTES: F:::___ REMOVE EXISTING 1-1/2"PVC CONDUIT AND WIRE SURFACE MOUNTED TO UNDERSIDE OF EXISTING BRIDGE TO BE REMOVED. PRIOR TO BRIDGE DEMOLITION FIELD VERIFY POWER SOURCE FOR SITE LIGHTING AND SAFE -OFF. IN EACH HANDHOLE DISCONNECT AND REMOVE ALL WIRING CROSSING BRIDGE TO BE REMOVED. PROVIDE WATER TIGHT CAPS ON EXISTING WIRES REMAINING UNTIL NEW BRIDGE CONSTRUCTION IS COMPLETED. CITY OF RENTON R-420240 IN COMPLIANCE WITH CITY OF RENTON STANDARDS GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT EXISTING BRIDGE DEMO ELECTRICAL PLAN DATE: F 1L B/17/20 PAGE: PAGE DRAWING NO: E-1 SHEET: OF: — 38 LO N LO O O T N U C0 C'7 O O O O 1 T N rr n N O N 0 W r, M N co O , N CROSS ENGINEERS, INC 923 MILK Jr. Way Phone: (253) 759-0118 O Tacoma, WA 98405 Job Number: 20-008 z info@crossengineers.com E O 16 RECORD DRAWING U0 THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED >, IN PART ON INFORMATION PROVIDED BY OTHERS. -0 CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE u) LICENSED ENGINEER OR LANDSCAPE ARCHITECT. J n AIntl r%I rr%/r f�A nT IKI 1'%r%. IP%r1rTr T%lr-%I %A1 rA t' l I WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 � � Z 002 s06o �� �FG/STER�� ss/ONAL N0. NEW BRIDGE ELECTRICAL PLAN SCALE: 1" = 5'-0" ELECTRICAL NOTES: CLEAN HANDHOLE LID AND FRAME. REMOVE RUST AND PAINT ATTACH 3/4" C-CHANNEL (HOT DIP GALVANIZED) WITH WITH COLD GALVANIZED PAINT (2 COATS). WELD NEW GROUND STAINLESS STEEL HARDWARE TO UNDERSIDE OF GRATING. LUGS TO FRAME AND LID. PROVIDE #8 BARE COPPER GROUND SEE STRUCTURAL SHEET S4 FOR GRATING SUPPORT WIRE TO LID AND FRAME WITH WATER TIGHT SPLICE FROM DETAIL. PROVIDE STAINLESS STEEL CONDUIT SUPPORTS GROUND WIRE SERVING LIGHTS. FROM C-CHANNEL ON MAXIMUM 5'-0" CENTERS. SEE STRUCTURAL FOR 2-1/2" ID SLEEVE (BLOCKOUT) LOCATION IN CONCRETE ABUTMENT. PROVIDE 1-1/2" SEISMIC COUPLING (APPLETON OR EQUAL) ON EACH SIDE OF CONCRETE ABUTMENT. GRAPHIC SCALE 5 0 5 10 1 "=5'-0" scale feet GRAPHIC SCALE BRIDGE ELECTRICAL ELEVATION 1"=5'-0" 5 0 5 10 SCALE: 1" = 5-0" scale feet RECORD DRAWINGS G4aTJ6`11011L1 SJK 11/17/23 SLH SURVEYED: DESIGNED: GLW DRAWN: JAE CHECKED: GLW BY DATE APPR APPROVED: SLH SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY GAT Y 0.41 PFNT02 CITY OF RENTON PROVIDE TWO(2) EXPANSION COUPLINGS IN PVC CONDUIT RUN BELOW BRIDGE. SPACE EQUALLY. R-420240 IN COMPLIANCE WITH CITY OF RENTON STANDARDS GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT NEW BRIDGE ELECTRICAL PLAN AND ELEVATION DATE: 1 1 /17/20 FIELDBOOK: — PAGE: PAGE DRAWING NO: E-2 SHEET: OF: — 38 LO LO O T N U co co O O O O T rr n