Loading...
HomeMy WebLinkAboutW-420201O CV U) 0) ._" 0) 0- 0 i 1 22 '20 �- 20 INSTALL 8" ISOLATION VALVE (RJxRJ) ON EXIST 8" WATER, — — V-8" SLEEVE (RJxRJ), VALVE TO BE CUT -IN BY CITY WATER POINT OF CONN (POC) TO EXIST WATERMAIN. MAKE DEPARTMENT. CONTRACTOR TO PROVIDE ALL MATERIALS, CONN TO EXIST LOWER VERT 22.50 BEND TO REMAIN. EXCAVATION AND RESTORATION, TYP REM ALL PIPING SOUTHEAST OF LOWER VERT BEND TO POC ON OPPOSITE END OF BRIDGE. SEE DETAILS $ & �11 A REMOVE TEMP BLOCK & 8" BLOW -OFF & CONNECT TO EXIST WATER LINE W/ SLEEVE AND DI SPOOLS, CONCRETE ABUTMENT, TYP FINAL CONNECTION BY CITY FORCES, TYP �OHW EXIST 8" DIP WATERMAIN 20 20 Oy 0 121 22 —22 TR W EXIST 8" C.I. 11.250 VERT BEND (MJ x MJ) - W W 21 `� EXIST PARK TRAIL 1 1 U EXIST JUNCTION BOX EXIST LIGHT POLE EXIST ULITITY POLE EXIST TREES x EXIST FENCE W_ EXIST 8"0 WATER MAIN w 8" DI WATER LINE E ELECTRICAL CONDUIT (SEE DRAWING E-02) Q OHw ORDINARY HIGH WATER LINE N M 00 co N CD N N U 0 C O O� L0 RECORD DRAWING co THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE c`n° LICENSED ENGINEER OR LANDSCAPE ARCHITECT. U) ca J WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003 2600 TEL: (206) 431-2300 FAX: (206) 431-2250 L F € E-- —E— _w W W �24 �Y 23--_ 2 8" CL 53 RESTRAINED JOINT DIP, WRAPPED W/ INSULATION E E E E E E E- W W W w w - Z-7 W- IJ n BRIDGE GIRDER, TYP SEE STRUCTURAL DRAWINGS FOR PIPE SUPPORTS & OFFSET LOCATION ON BRIDGE CL BRIDGE PLAN - WATER MAIN REPLACEMENT SCALE: 8 0 8 16 1" = 8' scale feet 24 23 22 _� 23 —20 POINT OF CONN (POC) TO EXIST WATERMAIN. MAKE CONN TO EXIST LOWER VERT 22.50 BEND TO REMAIN. —19. REM ALL PIPING NORTHWEST OF LOWER VERT BEND TO POC ON OPPOSITE END OF BRIDGE. SEE DETAILS C-8 & C-610 2' 2 9®B9� 14'-011± 10'-011± f•� a J I'11--___1ST 8" C.I. 450 HORIZ BEND _22 (MJ x MJ ) EXIST 8" C.I. WATERMAIN �23" \ 'EXIST 8" C.I. 450 HORIZ BEND (MJ x MJ) EXIST PARK TRAIL — \21. 20� NOTE: 1 FOR PIPE TRENCH DETAIL, SEE C-12 WORK POINT COORDINATES WP NORTHING EASTING W P 1 1301827.3032 189361.2657 W P2 1301793.2818 189457.1240 W-420201 IN COMPLIANCE WITH CITY OF RENTON STANDARDS I� 9 LO N O F� O U O W CV 0 C) 0 1 T a J D. NF was1 UPDATED PER CIVIL APPLICATION PERMIT GDN 3/22/22 GDN SURVEYED: SCALE: DAB: 2 RECORD DRAWING GDN 0/26/2 GDN DESIGNED: 1 "=20' 10/26/23 GDN CITY OF GENE COULON MEMORIAL BEACH PARK FIELDBOOK:FB RENTONPAGE s 6 ✓, % DRAWN: AH K ONE INCH TRESTLE BRIDGE REPLACEMENT 10 DRAWING NO., CHECKED: �� JjV AT FULL IF NOT ONE SC LE �SSIONAL F�G� o°� N0. REVISION BY DATE APPR �PROVEG N SCALE ACCORDINGLY CH PLAN -WATER UTILITIES SHEET: 1 2 OF, 45 n6 M O O O T