HomeMy WebLinkAboutzW-4202SetO CV U) 0) ._" 0) 0- 0 i 1 22 '20 �- 20 INSTALL 8" ISOLATION VALVE (RJxRJ) ON EXIST 8" WATER, — — V-8" SLEEVE (RJxRJ), VALVE TO BE CUT -IN BY CITY WATER POINT OF CONN (POC) TO EXIST WATERMAIN. MAKE DEPARTMENT. CONTRACTOR TO PROVIDE ALL MATERIALS, CONN TO EXIST LOWER VERT 22.50 BEND TO REMAIN. EXCAVATION AND RESTORATION, TYP REM ALL PIPING SOUTHEAST OF LOWER VERT BEND TO POC ON OPPOSITE END OF BRIDGE. SEE DETAILS $ & �11 A REMOVE TEMP BLOCK & 8" BLOW -OFF & CONNECT TO EXIST WATER LINE W/ SLEEVE AND DI SPOOLS, CONCRETE ABUTMENT, TYP FINAL CONNECTION BY CITY FORCES, TYP �OHW EXIST 8" DIP WATERMAIN 20 20 Oy 0 121 22 —22 TR W EXIST 8" C.I. 11.250 VERT BEND (MJ x MJ) - W W 21 `� EXIST PARK TRAIL 1 1 U EXIST JUNCTION BOX EXIST LIGHT POLE EXIST ULITITY POLE EXIST TREES x EXIST FENCE W_ EXIST 8"0 WATER MAIN w 8" DI WATER LINE E ELECTRICAL CONDUIT (SEE DRAWING E-02) Q OHw ORDINARY HIGH WATER LINE N M 00 co N CD N N U 0 C O O� L0 RECORD DRAWING co THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE c`n° LICENSED ENGINEER OR LANDSCAPE ARCHITECT. U) ca J WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003 2600 TEL: (206) 431-2300 FAX: (206) 431-2250 L F € E-- —E— _w W W �24 �Y 23--_ 2 8" CL 53 RESTRAINED JOINT DIP, WRAPPED W/ INSULATION E E E E E E E- W W W w w - Z-7 W- IJ n BRIDGE GIRDER, TYP SEE STRUCTURAL DRAWINGS FOR PIPE SUPPORTS & OFFSET LOCATION ON BRIDGE CL BRIDGE PLAN - WATER MAIN REPLACEMENT SCALE: 8 0 8 16 1" = 8' scale feet 24 23 22 _� 23 —20 POINT OF CONN (POC) TO EXIST WATERMAIN. MAKE CONN TO EXIST LOWER VERT 22.50 BEND TO REMAIN. —19. REM ALL PIPING NORTHWEST OF LOWER VERT BEND TO POC ON OPPOSITE END OF BRIDGE. SEE DETAILS C-8 & C-610 2' 2 9®B9� 14'-011± 10'-011± f•� a J I'11--___1ST 8" C.I. 450 HORIZ BEND _22 (MJ x MJ ) EXIST 8" C.I. WATERMAIN �23" \ 'EXIST 8" C.I. 450 HORIZ BEND (MJ x MJ) EXIST PARK TRAIL — \21. 20� NOTE: 1 FOR PIPE TRENCH DETAIL, SEE C-12 WORK POINT COORDINATES WP NORTHING EASTING W P 1 1301827.3032 189361.2657 W P2 1301793.2818 189457.1240 W-420201 IN COMPLIANCE WITH CITY OF RENTON STANDARDS I� 9 LO N O F� O U O W CV 0 C) 0 1 T a J D. NF was1 UPDATED PER CIVIL APPLICATION PERMIT GDN 3/22/22 GDN SURVEYED: SCALE: DAB: 2 RECORD DRAWING GDN 0/26/2 GDN DESIGNED: 1 "=20' 10/26/23 GDN CITY OF GENE COULON MEMORIAL BEACH PARK FIELDBOOK:FB RENTONPAGE s 6 ✓, % DRAWN: AH K ONE INCH TRESTLE BRIDGE REPLACEMENT 10 DRAWING NO., CHECKED: �� JjV AT FULL IF NOT ONE SC LE �SSIONAL F�G� o°� N0. REVISION BY DATE APPR �PROVEG N SCALE ACCORDINGLY CH PLAN -WATER UTILITIES SHEET: 1 2 OF, 45 n6 M O O O T O CV rr m 0 (2) ry U) Q U Q U) D I O 0 U WATER PLAN GENERAL NOTES Standard Plan No. 300 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION. 2. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL CALL 1-800-424-5555 TO VERIFY UTILITY LOCATIONS BEFORE BEGINNING EXCAVATION. 3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND "CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY MATERIALS ON -SITE. 4. ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C 104. PIPE JOINTS SHALL BE PUSH -ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS PER ANSI/AWWA C110/A21.10-82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8-MIL BLACK, TUBE -TYPE, POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS. 5. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10-INCH OR LESS AND 48 INCHES FOR PIPE DIAMETER OF 12-INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60 INCHES. ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST METHOD (MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MDD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD. 6. CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS (OR SIMILAR PRODUCT) MAY BE REQUIRED ON ALL MECHANICAL JOINTS IN ADDITION TO CONCRETE BLOCKING. 7. ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALL AND REMOVE PLUGS, CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITY TESTING. 8. NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BE TAKEN FOR PURITY TESTING BY THE PUBLIC WORKS INSPECTOR. 9. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SHORING AND ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION. Y o STD. PLAN - 300.0 +' * PUBLIC WORKS WATER PLAN GENERAL NOTES DEPARTMENT MARCH 2O10 o� LO LO RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS. CHANGES SHOWN HAVE BEEN PROVIDED BY THE > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE c`n° LICENSED ENGINEER OR LANDSCAPE ARCHITECT. J DETAIL - WATER GENERAL NOTES SCALE: NTS WSP USA Inc. 33301 9th Avenue South Suite 300 Federal Way, WA 98003-2600 TEL: (206) 431-2300 FAX: (206) 431-2250 NO. C EXISTING DO NOT —a— 1 r) F- TEE, DEAD END LI N DISTURB BLOCKING TESTING DETAIL VERTICAL CROSS (MJxFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP WITH 2"TAP & 2"PLUG 1-BLIND FLANGE ON BOTTOM 1-PLUG(MJ) W/2"TAP & 2" BLOW -OFF TEMP. BLOCK FINAL CONNECTION DETAIL Zy�nmEffliy" 1119 EXIST. WATER LINE AFTER ALL TESTING, CLEANING BY POLYPIG AND DISINFECTION, REMOVE TEMP. BLOCK & BLOW -OFF & CONNECT TO EXISTING WATER LINE WITH SLEEVE (MJ) AND D.I. SPOOLS FINAL CONNECTION BY CITY FORCES zY & �* PUBLIC WORKS CONNECTION TO WATER MAIN STD. PLAN - 300.5 DEPARTMENT EXISTING TEE OR END LINE CAP rV MARCH 2O10 ('_2DETAIL - C-7 SCALE: NTS TIE INTO EXISTING END LINE CAP W-420202 IN COMPLIANCE WITH CITY OF RENTON STANDARDS SURVEYED: SCALE: 1 20 CITY OF RENTONr+i GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT E M E N T DETAILS - WATER UTILITIES SHEET 1 DATE: 10/26/23 DESIGNEDGDN FlELDBOOK: FB PAGE: E DRAWN: AH K ONE INCH DRAWING N ., C - 8 CHECKED: CHECKED:, AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY REVISION BY DATE AP P R APPROVED: GDN SHEET. 13 OF, 45 CV O O O O T a J O O O T O N� POINT OF CONN TO EXIST WATERMAIN, N SEE 2 IIi C-8 2 L m a� U) O EXIST 8" DIP E Q U U) O FIELD LOCATE AND DEMO EXIST LOWER VERTICAL UBEND & CONC THRUST BLOCK. PROVIDE REPLACEMENT VERTICAL DI 22.50 BEND (RJ) W / CONC THRUST BLOCK, SEE NOTE 3 1 C-9 USE MEGALUG SERIES 1100 MJ RESTRAINT OR EQUAL 8" DIP RJ-SPIGOT X PE PIPE BETWEEN FITTINGS, LENGTH AS REQ'D FOR ELEV DIFFERENCE BETWEEN EXISTING PIPE AND PIPE GOING THRU ABUTMENT. — PIPE SUPPORT 0 U. FACE OF CONC CL ABUTMENT ABUTMENT PILE ±6' TO 8' 5'-3" 3'-0" 11" FINISH GRADE 1'-011± EXISTING GRADE 4 LF 8" DIP, FL X FL --\ -------------------------------- 8"0 DIP RJ-SPIGOT x TR-FLEX o RJ-SPIGOT LENGTH AS REQ'D RJ x FL ADAPTER cn SEE NOTE 3 O O -7— Oo O FL CONN BETWEEN DIP AND FLEX -TEND FORCE BALANCEDU� FLEX TEND EXPANSION JOINT (FL x FL) BEGIN PRE -INSULATED PIPE FOR BRIDGE AT FLANGE OF O BURIED FLEX -TEND, SEE NOTE 4. O O O DO INSULATION NOT SHOWN. O FIELD LOCATE AND DEMO EXIST UPPER VERTICAL BEND & CONC THRUST BLOCK. SEAL ANULAR SPACE PROVIDE REPLACEMENT VERTICAL DI 22 5° ±15' END OF RJ PIPE BELL - ff - - - - IF - - - - IPF - - - - - - - ]r 8" DIP FL x FL LENGTH 8" DI 11.250 BEND, FL x FL 8" DIP FL x RJ SPIGOT AS REQ'D FOR VERT & (ROLL FITTING TO MEET HORIZ OFFSET REQ'D VERT & HORIZ OFFSET) ----�----------- 8" FORCE BALANCED FLEX -TEND EXPANSION JOINT (FL x FL), W/ ONE END ROTATED AS REQ'D FOR HORIZ & VET OFFSET PIPE RESTRAINT ANCHOR, SEE DRAWING S-14 FOR DETAILS BEND (RJ) W / CONC THRUST BLOCK, SEE 2 BETWEEN HOLE THRU 18" DIA. HOLE FOR PENETRATION ABUTMENT AND EXTERIOR ' SEE STRUCTURAL FOR DETAILS C-9 PIPE JACKET, SEE NOTE 2, TYP A SECTION - NORTH FLEXIBLE EXPANSION JOINT C-7 SCALE: 1 0 1 2 3/4" = 1'-0" MENEMEd scale feet CL ABUTMENT FACE OF CONC PILE ABUTMENT ±15' 11" 3'-0" 5'-3" 1'-0"± /--- 4 LF 8" DIP, FL X FL STEEL EXTERIOR GIRDER ±6' TO 8' FINISH GRADE EXISTING GRADE --\ 6"+ 1'-10" TYP PIPE SUPPORT L0 N o Qo � U � O W PIPE INSULATION, TYP ALL ] C\1 EXPOSED PIPE & FITTINGS O O PIPE SUPPORT WELDED TO CHANNEL CI (RESTRAINED LATERALLY & VERTICALLY N W/ PTFE SLIDE PAD TO ALLOW AXIAL a MOVEMENT), SEE NOTE 1. ------ —------- ------ — CD 8" DIP FL x FL LENGTH �' FL CONN BETWEEN �— AS REQ'D FOR VERT & DIP AND FLEX -TEND o o HORIZ OFFSET 9 SEE NOTE 3 rn TR-FLEX 8"0 DIP RJ-SPIGOT x o - - -� - _ F00 � RJ-SPIGOT LENGTH AS REQ'D RJ x FL ADAPTER -------------------------------- W— a) 0 _J 8" DIP FL x RJ BELL 8" DI 11.250 BEND FL x FL (ROLL FITTING TO STEEL O O PIPE INSULATION, TYP ALL MEET REQ'D VERT & HORIZ OFFSET EXTERIOR 8" FORCE BALANCED ' > EXPOSED PIPE & FITTINGS BETWEEN PIPE LOCATION ON BRIDGE AND GIRDER FLEX -TEND EXPANSION FORCE BALANCED m PIPE PENETRATION THRU CONC ABUTMENT) JOINT (FL x FL), W/ONE FLEX TEND EXPANSION NOTES: END ROTATED AS REQ'D JOINT (FL x FL) FOR HORIZ &VET OFFSET O LO 1. PROVIDE PIPE SUPPORTS AND SUPPORTING CHANNELS ON BRIDGE. LOCATE BEHIND EACH OO BEGIN PRE -INSULATED PIPE PIPE BELL AS SHOWN, WITH SPACING NO GREATER THAN 20' OC. PIPE SUPPORTS SHALL NOT O FOR BRIDGE AT FLANGE OF a- BE LOCATED ON SPIGOT END OF PIPE. PIPE SUPPORTS TO PROVIDE LATERAL AND VERTICAL PIPE RESTRAINT ANCHOR, D \ j/\j/\j/\j/\j /\jam\� BURIED FLEX -TEND, SEE NOTE 4. FIELD LOCATE AND DEMO EXIST UPPER SEE DRAWING S-14 FOR DETAILS OO \ \ \ \ \ \ \ 3: RESTRAINT OF PIPE AND SHALL HAVE PTFE SLIDE PAD TO ALLOW AXIAL MOVEMENT. PIPE OO /� \//\//\//\//\//\ �INSULATION NOT SHOWN. VERTICAL BEND & CONC THRUST BLOCK. /� O /� '\\�O/i��//�\��\ PROVIDE REPLACEMENT VERTICAL DI 22.5° SUPPORT SHALL BE PIPE SHIELDS MODEL B4200 OR APPROVED EQUAL, MODIFIED TO FIT A BEND (RJ) W / CONC THRUST, SEE 2 (.0 PRE -INSULATED DIP HAVING OD OF 14.1" AND THE PIPE SUPPORT SUPPLIED 24 GAGE SHEET 18 DIA. HOLE FOR PENETRATION SEAL ANULAR SPACE z METAL JACKET. DO NOT USE THE PIPE SUPPORT SUPPLIED INSULATION. WELD BASE OF SEE STRUCTURAL FOR DETAILS BETWEEN HOLE THRU C-9 co SUPPORT TO STRUCTURAL CHANNEL. SEE DRAWING S-13 FOR DETAILS. ABUTMENT AND EXTERIOR PIPE JACKET, SEE NOTE 2, TYP 2. PROVIDE MODULAR LINKSEAL NEAR OUTSIDE EDGE OF PIPE PENETRATION TO SEAL ANNULAR 8" DIP RJ-SPIGOT X PE PIPE BETWEEN SPACE BETWEEN PRE -INSULATED PIPE HAVING O.D. OF 14.1 INCHES AND 18 DIA HOLE SECTION -SOUTH FLEXIBLE EXPANSION JOINT FITTINGS, LENGTH AS REQ'D FOR ELEV THROUGH ABUTMENT. SEAL ELEMENT SHALL BE EPDM (BLACK), COMPOSITE PRESSURE B PLATES, AND 316 STAINLESS STEEL BOLTS AND NUTS. TEMPERATURE RANGE -40 F TO +205 F. C-7 SCALE: 1 0 1 2 DIFFERENCE BETWEEN EXISTING PIPE Q LINKSEAL MODULAR SEAL MODEL LS-360-S-316 FOR 18" DIA CAST CONCRETE HOLE OR 3/4" = 1'-0" mmommll AND PIPE GOING THRU ABUTMENT. — M APPROVED EQUAL. PROVIDE V-0" (MIN) LONG 24 GAGE SHEET METAL JACKET AROUND scale feet 00 ENTIRE PIPE AT LOCATION OF LINKSEAL, AND INSTALL LINKSEAL WITH CARE TO AVOID 4. ALL PIPING ON BRIDGE AND THROUGH ABUTMENT TO FLANGE OF BURIED FLEX -TEND ON 6. ALL WATER FITTINGS AND VALVES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAVE A N DAMAGING THE INSULATION JACKET THAT COULD CAUSE MOISTURE INTO THE INSULATION. EACH SIDE OF BRIDGE SHALL BE PRE -INSULATED DUCTILE IRON PIPE WITH EITHER TR-FLEX WEDGE -TYPE RETAINER GLAND FOUAL TO MFGALUG SERIES 1100. N 3. POT -HOLE EACH WATER PIPE CONNECTION LOCATION TO CONFIRM LOCATION AND DEPTH RESTRAINED JOINTS OR FLANGE JOINTS AS SHOWN. U OF EXISTING PIPE AT LOWER 22.5 DEG BEND PRIOR TO DEMOLITION (CONNECTION 5. ALL BURIED DUCTILE IRON PIPE AND BURIED FLEX TEND SHALL BE WRAPPED WITH o� LOCATION). POLYETHYLENE ENCASEMENT (POLYWRAP) IAW AWWA C105. LO RECORD DRAWING WWAs�� 1 UPDATED PER CIVIL APPLICATION PERMIT GDN 3/22/22 GDN SURVEYED: SCALE: WSP USA Inc. c� 2 RECORD DRAWING GDN 0/26/2 GDN DESIGNED: 1 » 20' CITY OF THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED C> o IN PART ON INFORMATION PROVIDED BY OTHERS. 33301 9th Avenue South GDN Suite 300 DRAWN: CHANGES SHOWN HAVE BEEN PROVIDED BY THE RENTON � Federal Way WA 98003-2600 ,/ AHK ONE INCH > CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE TEL: (206) SCALE 431-2300 �' ? 50226 0 �� CHECKED: ' Off, FR� � '� AT FULL cocn LICENSED ENGINEER OR LANDSCAPE ARCHITECT. FAX: 206 CtsTEJJV 431-2250 �� ti IF NOT ONE INCH in SstONAl- F�� 60°� NO. REVISION BY DATE APPR APPROVED: GDN SCALE ACCORDINGLY J EXIST 8" DIP — POINT OF CONN TO EXIST WATERMAIN, SEE 2 C-8 — FIELD LOCATE AND DEMO EXIST LOWER VERTICAL BEND & CONC THRUST BLOCK. PROVIDE REPLACEMENT VERTICAL DI 22.50 BEND (RJ) W / CONC THRUST BLOCK, SEE NOTE 3 & 1 USE MEGALUG SERIES 1100 C 9 MJ RESTRAINT OR EQUAL W-420204 IN COMPLIANCE WITH CITY OF RENTON STANDARDS GENE COULON MEMORIAL BEACH PARK TRESTLE BRIDGE REPLACEMENT DETAILS - WATER UTILITIES SHEET 3 10/26/23 FIELDBOOK: FB PAGE` PAGE DRAWING NO: C-10 SHEET. rJ OF. 1 45 J C'7 C'7 O O O T