SWALE FOR SURFACE DRAINAGE CONTROL
COMPACTED NATIVE FILL
I 1
10' MAX
EXPOSED WALL
HEIGHT
6
I
2(MAX) H13
, l_1 5' MIN
I -I GUARD RAIL PER CIVIL
PLANS
II
ROADWAY
6" MIN COVER OVER
REINFORCMENT
I I I LAYER 6 1
0.5' TYP -
I Li T
_LAYER 5 - -
SMIN �`� REINFORCEMENT GRID
I (SEE SCHEDULE)
12" MIN _LAYER 4 - -
"L"
-LAYER 3- - -
\ CRUSHED ROCK FILTER
MATERIAL, BETWEEN 2
AND 4 INCH SIZE WITH
_ LAYER 2 LESS THAN 2% FINES
\ 2 TYP
I
`_ LAYER 1 -
0.5'
r3" MINIMUM
n t GRAVEL BEDDING 1.01
f --KEYWAY 1N
FIRM UNDISTURBED MIN
SOIL TO BE VERIFIED
BY GEOTECHNICAL ENGINEER
KEYWAY SHOULD BE SLOPED
DOWN TOWARDS THE FACE
BEING PROTECTED
NOT TO SCALE
BUILDING LOT
10,
(max.)
1'(min�
4"
7'
2(MAX)
1
nc�rnv�.n /
41" TOP BLOCK
REDI-ROCK
60" MIDDLE BLOCK
REDI-ROCK
60" MIDDLE BLOCK
1
2 REDI-ROCK
60" MIDDLE BLOCK
REDI-ROCK
60" MIDDLE _BLOCK
e
9" REDI-ROCK
60" MIDDLE BLOCK
REDI-ROCK 2
60" BOTTOM BLOCK '
9" OFFSET
COMPETENT NATIVE SOILS
OR STRUCTURAL FILL TO BE VERIFIED
BY GEOTECHNICAL ENGINEER (TYP.)
NOT TO SCALE
ASBU/LT NOTE
4" MINIMUM DIAMETER
DRAIN PIPE SURROUNDED BY
CLEAN WASHED 3/4" DRAIN
GRAVEL
12" MIN. COMPACTED STRUCTURAL
BACK FILL ABOVE DRAIN COLUMN
DENSE NATIVE SOILS
12" MIN. COMPACTED 1/2" TO 1"
CLEAN CRUSHED ROCK NO FINES (TYP.)
EXCAVATION TO BE COMPLETED
AT THE BACK OF THE DRAINAGE
COLUMN TO LIMIT THE AMOUNT
OF DENSE NATIVE MATERIAL
REMOVED FROM BEHIND THE WALL.
4" DIAMETER PERFORATED PVC
DRAIN PIPE TAKEN TO APPROVED
POINT OF DISCHARGE
5/8" CRUSHED ROCK LEVELING PAD (TYP.)
THE ASBUIL T INFORMA 110N DEPICTED ON THESE PLANS /S BASED UPON FIELD SURVEY
INFORMA110N PROVIDED BY CORE DESIGN AND SUPPLEMENTED BY SITE CONTRACTOR,
GOODFELLOW BROTHERS, ON ✓ANUARY 29TN, 2024. GOODFELLOW BROTHERS INDICATES
THAT THE DATA PROVIDED TO CORE DESIGN ACCURATEL Y REPRESENTS FIELD
CONDl110NS ON THE DA TE OF THEIR SURVEY. CORE DESIGN HAS REV/f ED THE
INFORMA 110N PROVIDED FOR GENERAL CONFORMANCE K4TN THE DESIGN CONCEPT, AND
TO THE BEST OF OUR KNOK2EDGE THE INFORMA 110N /S IN ACCORDANCE W771 THE
OBSERVED FIELD CONDITIONS.
REINFORCED FILL ROCKERY REINFORCING SCHEDULE
OVERALL WIDTH
(includes stone size
REINFORCEMENT
HEIGHT
at base of wall, wall
EXPOSED WALL
LAYER NO.
(USE MIRAFI OR
LENGTH "L" FEET
(ABOVE BASE
batter, drain rock,
HEIGHT
EQUIVALENT)
ELEVATION)
and reinforcement)
3.25 FEET
4 FEET OR LESS
NO REINFORCEMENT REQUIRED
8.25 FEET
5 FEET
1
MIRAM HP 570
4.5
0.5
2
MIRAM HP 570
4,5
2.5
1
MIRAFI HP 570
5-5
0.5
10 25 FEET
6 - 7 FEET
2
MIRAFI HP 570
5.5
2.5
3
MIRAFI HP 570
5.5
4.5
1
MIRAR HP 570
7.5
0.5
2
MIRAFI HP 570
7.5
2.5
13.25 FEET
B - 9 FEET
3
MIRAFI HP 570
7.5
4.5
4
MIRAFI HP 570
7.5
6.5
1
MIRAFI HP 570
9.0
0.5
2
MIRAFI HP 570
9.0
2Z
15.25 FEET
10 FEET
3
MIRAFI HP 570
9-0
45
4
MIRAFI HP 570
5
MIRAFI HP 570
ROCKERY NOTES:
1. ROCKERY CONSTRUCTION SHALL BE COMPLETED
IN ACCORDANCE WITH THE ASSOCIATION OF
ROCKERY (ARC) CONTRACTORS GUIDELINES.
2. ROCK USED MUST MEET THE REQUIREMENTS
FOR ROCK QUALITY SPECIFIED IN SECTIONS 9-13.7(1)
OF THE WSDOT STANDARDS SPECIFICATIONS (2016).
3. ALL CAP ROCKS MUST BE SECURE AND NOT ABLE
TO BE DISLODGED BY HAND.
GENERAL REINFORCED FILL NOTES:
1. REFER TO CIVIL DRAWINGS FOR ROCKERY ALIGNMENT, LOCATIONS AND ELEVATIONS.
2. REFER TO REINFORCING SCHEDULE FOR GEOTEXTILE LENGTHS AND ELEVATIONS.
3. GEOTEXTILE SHALL BE INSTALLED ON HORIZONTAL SURFACE OF COMPACTED STRUCTURAL
FILL AT ELEVATIONS SHOWN ON SCHEDULE.
4. GEOTEXTILE SHALL BE PULLED TIGHT BEHIND WALL. STAKE END OF GEOGRID AS
REQUIRED TO MAINTAIN TENSION BEFORE COVERING WITH STRUCTURAL FILL.
5. PROTECT GEOTEXTILE FROM CONSTRUCTION DAMAGE PER MANUFACTURERS CONSTRUCTION
EQUIPMENT SHALL NOT TRAVEL DIRECTLY ON GEOTEXTILE. ANY GEOTEXTILE THAT IS
DAMAGED SHALL BE REPLACED WITH NEW GEOTEXTILE AT CONTRACTORS EXPENSE.
6. GEOTEXTILE SHALL BE AS SHOWN ON SCHEDULE. ALL GEOTEXTILE SHALL BE CLEARLY
IDENTIFIED AND LABELED IN THE FIELD. ANY UNMARKED ROLLS, OR PORTIONS THEREOF, OF
GEOTEXTILE THAT CANNOT BE IDENTIFIED SHALL NOT BE USED IN WALL CONSTRUCTION.
7. ALL STRUCTURAL FILL TO BE PLACED AND COMPACTED PER REPORT PREPARED BY TERRA ASSOCIATES,
PROJECT NUMBERS, T-7886, PREPARED BY TERRA ASSOCIATES, INC., DATED
FEBRUARY 21, 2020. STRUCTURAL FILL IN RE-INFORCED ZONE SHALL BE
GRANULAR MATERIAL WITH A MAXIMUM AGGREGATE SIZE OF 3 INCHES AND A MAXIMUM OF 30 PERCENT
PASSING THE NO.200 SIEVE (FINES CONTENT) BASED ON THE 3/4" GRAVEL FRACTION.
GENERAL NOTES
1) REFER TO CIVIL GRADING PLANS FOR WALL ALIGNMENTS AND ELEVATIONS.
2) REDI-ROCK ® WALL ASSEMBLY TO BE COMPLETED PER MANUFACTURERS
SPECIFICATIONS.
3) HEAVY CONSTRUCTION EQUIPMENT SUCH AS VIBRATORY DRUM ROLLERS, LOADED DUMP
TRUCKS, FRONT-END LOADERS, ETC., SHALL NOT OPERATE WITHIN FIVE FEET OF BACK OF
WALLS. STRUCTURAL FILL PLACED IN THIS ZONE SHALL HAVE MAXIMUM LOOSE LIFT
THICKNESS OF 12 INCHES AND SHALL BE COMPACTED USING HAND OPERATED
COMPACTION EQUIPMENT.
UNDERGROUND LOCATOR SERVICE
CALL BEFOREq YOU DIG.
O�NNS.�F
O� WAshi 0
T 9 4' 6 <C/�
/STEC��O
S/DNA L
1 1 CONSTRUCTION RECORD DRAWINGS
REVISION
FENCE/RAIL WHERE
REQUIRED
n
4.5'
I
II
II
ROADWAY
REDI-ROCK
4.5
41" PLANTER BLOCK .
(max.)
REDI-ROCK
' 41" MIDDLE BLOCK
•a
2(MAX) j
1 IN
REDI-ROCK '
' '41" BOTTOM BLOCK
1
J-
4 "
T
COMPETENT NATIVE SOILS
OR STRUCTURAL FILL TO BE VERIFIED
BY GEOTECHNICAL ENGINEER (TYP.)
NOT TO SCALE
L 12" MIN. COMPACTED STRUCTURAL
Li BACK FILL ABOVE DRAIN COLUMN
i
12" MIN. COMPACTED 1/2" TO 1"
CLEAN CRUSHED ROCK NO FINES (TYP.)
i STRUCTURAL FILL
4" DIAMETER PERFORATED PVC
DRAIN PIPE TAKEN TO APPROVED
POINT OF DISCHARGE
5/8" CRUSHED ROCK LEVELING PAD (TYP.)
FENCE OR HANDRAIL
AS REQUIRED
SWALE FOR SURFACE DRAINAGE CONTROL
1
10' MAX.
2(MAX)
1 �-
FIRM UNDISTURBED
SOIL TO BE VERIFIED
BY GEOTECHNICAL ENGINEER
u
KEYWAY SHOULD BE SLOPED
DOWN TOWARDS THE FACE
BEING PROTECTED
NOT TO SCALE
ROCKERY NOTES:
1. REFER TO CIVIL GRADING DRAWINGS FOR
WALL ALIGNMENTS, AND ELEVATIONS.
2. ROCKERY CONSTRUCTION SHALL BE COMPLETED
IN ACCORDANCE WITH THE ASSOCIATION OF ROCKERY
CONTRACTORS GUIDELINES.
3. ROCK USED MUST MEET THE REQUIREMENTS
FOR ROCK QUALITY SPECIFIED IN SECTION 9-13.7(1)
OF THE WSDOT STANDARDS SPECIFICATIONS (2016).
4. ALL CAP ROCKS MUST BE SECURE AND NOTABLE
TO BE DISLODGED BY HAND.
COMPETENT UNDISTURBED NATIVE SOILS
CRUSHED ROCK FILER
MATERIAL BETWEEN 2,
AND 4 INCH SIZE WITH
LESS THAN 2% FINES
- 4" MIN
GRAVEL BEDDING
4" MINIMUM DIAMETER
DRAIN PIPE SURROUNDED BY
CLEAN WASHED 3/4" DRAIN
GRAVEL TAKEN TO APPROVED
POINT OF DISCHARGE
OVERALL WIDTH
(includes stone size
at base of wall, wall
EXPOSED WALL
batter, and drain
HEIGHT
rock)
3.25 FEET
4 FEET OR LESS
8.25 FEET
5 FEET
10,25 FEET
6 - 7 FEET
13.25 FEET
8 - 9 FEET
15.25 FEET
10 FEET
Terra CUT ROCKERY DETAIL
CANOPY
Associates, Inc. RENTON, WASHINGTON
Consultants in Geotechnical Engineering
Geology and
Environmental Earth Sciences Proj.No. T-7886 Date: MAR 2022 Figure 2
MEM
2/13/24
HHH
LENN R SPRAGUE P.L.S
sue.
AS NOlGD
DESIGNED:
HOLLI HEA VRIN
DRAWN:
MARY MOORE
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
CHECKED:
HOLLI HEA VRIN
BY
DATE
APPR
APPROVED:
HOLLI H. HEA VRIN P.E.
GENERAL NOTES
1) REFER TO CIVIL GRADING PLANS FOR WALL ALIGNMENTS AND ELEVATIONS.
2) REDI-ROCK ® WALL ASSEMBLY TO BE COMPLETED PER MANUFACTURERS
SPECIFICATIONS.
3) STRUCTURAL FILL SHALL BE PLACED AND COMPACTED ACCORDING TO
RECOMMENDATIONS PROVIDED IN THE GEOTECHNICAL REPORT, CANOPY, RENTON,
WASHINGTON, PROJECT NO. T-7886 PREPARED BY TERRA ASSOCIATES, INC., DATED
FEBRUARY 21, 2020. STRUCTURAL FILL IN REINFORCED ZONE SHALL BE GRANULAR
MATERIAL WITH A MAXIMUM AGGREGATE SIZE OF 3-INCHES AND A MAXIMUM SOIL FINES
(LESS THAN # 200 SIEVE) CONTENT OF 30 PERCENT.
4) HEAVY CONSTRUCTION EQUIPMENT SUCH AS VIBRATORY DRUM ROLLERS, LOADED DUMP
TRUCKS, FRONT-END LOADERS, ETC., SHALL NOT OPERATE WITHIN FIVE FEET OF BACK OF
WALLS. STRUCTURAL FILL PLACED IN THIS ZONE SHALL HAVE MAXIMUM LOOSE LIFT
THICKNESS OF 12 INCHES AND SHALL BE COMPACTED USING HAND OPERATED
COMPACTION EQUIPMENT.
RED/ -ROCK WALLS
ALL RED/ -ROCK WALLS SHALL BE FACED WITH
COBBLESTONE TEXTURE AS SHOWN, OR APPROVED EQUAL.
NOTE
THE WALL DESIGNS, AS SHOWN ON THIS SHEET, HAVE BEEN
PRO KDED BY THE PROJECT GE07ECHNICAZ ENGINEER, TERRA
ASSOCIATES. /T IS INCLUDED WITH THIS PLAN SET AS
COURTESY AND FOR lS INFORMATIONAL PURPOSES ONLY.
CORE DESIGN, INC. TAKES NO RESPONSIBILITY OR LIABILITY
FOR THE DESIGN. FOR QUES70NS REGARDING THIS DESIGN,
CONTACT TERRA ASSOCIATES.
CoffCIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
`11111z=�
DESIGN SURVEYING
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
R-417925
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
HORIZO A - HAD 1983/199, ' C I TY 0 F CANOPY� ~ 211.3124
R 4196L/NCOLNAVE NE, RENTON, WA 98056 FlELDBOOK:
RENTON PAGE
DATUM VXAV DRAWING NO:
Planning/Building/Public Works Dept. C3,32
SITE DETAILS 25 OF. 107
CONSTRUCT/ON RECORD DRA WINGS