Loading...
HomeMy WebLinkAboutR-417949DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 ON FACE OF CURB 61n"- s1n 1" 1ZR 1"R 1:24 I •Z. I TOP OF 112" R. ROADWAY l I r 1 6" CEMENT CONCRETE TRAFFIC CURB AND GUTTER FACE OF ADJACENT CURB 6 12"--FACE WITH GUTTER PAN AT SIDEWALK RAMP ENTRANCE 1 12 1:24 TOP OF 1/2" R. ROADWAY 1 ro I _ 1 6" - DEPRESSED CURB SECTION AT SIDEWALK RAMPS 3I8" _ 6" _ CEMENT CONCRETE 12" R. 1• R SIDEWALK RAMP VARIES OR LANDING FROM I 6"TOO 1 6" I 3/B" PREMOLDED JOINT FILLER CEMENT CONCRETE PEDESTRIAN CURB AT SIDEWALK RAMPS AND LANDINGS FACE OF ADJACENT CURB 6 12"- SEE DEPRESSED CURB DETAIL THIS SHEET 1:24 TOP OF 1. 1/2"R. ROADWAY 2 I I io I 1 6- _ DEPRESSED CURB SECTION AT RESIDENTIAL DRIVEWAYS ONLY. FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 104.2 FACE OF CURB I FACE OF ADJACENT CURB GUTTER SURFACE o gip, 'P PREMOLOED JOINT FILLER E FULL -DEPTH EXPANSION JOINT 6 1/2" s 1n" r 12" R. 1" R. 1 I TOP OF ROADWAY v r 1 8 114" ` CEMENT CONCRETE TRAFFIC CURB DEPRESSED CURB DETAIL AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS, AND ALLEYS GENERAL NOTES: 1. See standard plans 102 and 101.1 for curb expansion and contraction joint spacing. 2. Expansion joint shall be full depth, 3/8" (in.) premolded joint filler. 3. For Depressed Monolithic Driveway Curb 8. Gutter Section, see Standard Plan 104.2 STD. PLAN - 101 a PUBLIC WORKS DEPARTMENTCEMENT CONCRETE CURBS , SEE NOTE R,3/8'R X 5/8"D DUMMY JOINT 3/8" PREMOLDED JOINT FILLER (TYP) b BEE NOTE 2 CEMEWCONCRElE CURB AND GUTTER FACE OF +_ CENTERLINEOF FRAME 6 ORATE cum 6 t 2" 13' (I:OB') .. 51 2' 1' FRAMEAND (IRATE -NOT INEWDED 1 /2' R. 1' R. SAY IN CURB AND DIDTESRBID ITEM • 0 3' m TOP OF � RECE>� ROADWAY •• • p.•. o•'••• ADJUSTMENT SECTION -NETTINCLUDED ►• e' INCURSAND GUP'IERBIDTIEM '. •� '. CATCH BASIN -NOT INCLIIDEO o • IN CIRB AND GUTTER END REM S. SECTION O GENERAL NOTES: J1 1. The Intent of this design is to facilitate the removal' of a catch basin with minimal disturbance r r of the curb. 2. The expansion jolnts of the adjacent sidewalk shall be -adjusted to be In fine with these curb f �' expansion joints. .:�.; =�.' I xl •' ISO!AE41C VIEW ® CEMENT CONCRETE CURB 57D• PLAN - 101,1 + PUBLIC WORKS CATCH BASINS INSTALLATION AT PRO D: •" DEDEPARTMENT UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG. 8/ 1 1 CONSTRUCTION RECORD DRAWINGS •ra o n' Lunl --- - --- EXISTING ASPHA PAVEMENT SAWCUT (SEE NOTE 2) RTERIAL STREET MINIM 7" HMA (or ACP Class B) (SEE NOTE 1), OVER 6" CRUSHED ROCK RESIDENTIAL STREET MINIMUM I 4" HMA (or ACP Class B) (SEE NOTE 1), OVER 6" CRUSHED ROCK NOTES: 1. MUST MATCH EXISTING THICKNESS IF GREATER. 2. SAWCUT SHALL BE POSITIONED 1' -- 0" BEYOND EDGE OF DAMAGED PAVEMENT. 1 THE INTENT OF THIS DESIGN IS TO DESCRIBE PAVEMENT PLACEMENT AT 'THE GUTTER FACE. SEE STANDARD PLAN FOR CEMENT CONCRETE CURBS. STD. PLAN - 103 + PUBLIC WORKS CURB AND GUTTER \ PPRO D: DEPARTMENT REPLACEMENT DETAIL y �Lt`j0 ATE M E M 2/ 13/24 H H H SURVEYED: LENN R. SPRAGUE P.L.S. SCALE: AS NOTED DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORF ONE INCH CHECKEDH OLLI HEA VRIN AT FULL S IF NOT ONEC NCH SCALE ACCORDINGLY BY DATE APPR APPROVED: ROLL/ H. HEA VR/N P. E. VERTICAL NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM �V,2'4",6", 12", OR 24" ONE #3 BAR HHHOOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION 6 �a0 E 16 0 D" #3 BAR EACH CORNER sFF z2„ \OTF� #3 BAR EACH SIDE #3 BAR EACH WAY PRECAST BASE SECTION #3 BAR HOOP #3 BAR EACH CORNER 18" MIN. SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION • PUBLIC WORKS '1` DEPARTMENT 11 CITY OF '� 1 RENTON Planning/Building/Public Works Dept. PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN CONCRETE 12" ALL METAL PIPE 15" CPSSP", STD. SPEC. 9-05.20 12" SOLID WALL PVC, STD. SPEC. 9-05.12(1) 15" PROFILE WALL PVC, STD. SPEC. 9-05.12(2) 15" ' CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: 1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. 2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET. 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. 5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1H:24V OR STEEPER. 6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 200.00 APPR ED: CATCH BASIN TYPE 1 GAZ 9/28/2018 °mm wo,k: nemmima,°, DATE :45 Al ASBUIL T NOTE THE ASBUIL T INFORMA TION DEPICTED ON THESE PLANS IS BASED UPON FIELD SURVEY INFORMATION PROVIDED BY CORE DESIGN AND SUPPLEMENTED BY SITE CONTRACTOR, GOODFELLOW BROTHERS, ON ✓ANUARY 297H, 2024. GOODFELLOW BROTHERS INDICATES THAT THE DATA PROVIDED TO CORE DESIGN ACCURATEL Y REPRESENTS FIELD CONDITIONS ON THE DATE OF THEIR SURVEY. CORE DESIGN HAS RE/IEWED THE INFORMATION PROVIDED FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT, AND TO THE BEST OF OUR KNOWLEDGE THE INFORMA TION /S IN ACCORDANCE WITH THE OBSERVED FIELD CONDITIONS. �pK INS h, o wAsyfF CIVIL ENGINEERING o, z LANDSCAPE ARCHITECTURE Z• PLANNING 99 �.� DESIGN SURVEYING ISTER � IONAL 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 2/13/24 R-417949 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CANOPY 4196 LINCOLN AVE NE, RENTON, WA 98056 STORM DRAINAGE STANDARD DETAILS O O O O Z DATE: CT 211JI24 V FIELDBOOK: PAGE DRAWING NO: C4.36 SHEET: OF, 49 107 CONSTRUCT/ON RECORD DRA WINGS