HomeMy WebLinkAboutR-417981O
Q
FROM SOURCE
IRRIGATION WATER METER (1") CONNECTION AND WATER METER
GALVANIZED PIPE TO POINT OF CONNECTION
VALVE BOX
MUELLER SHUT OFF VALVE
WILKENS Y5 100 STRAINER 1 1/2"
PRESSURE REDUCING VALVE
APPROVED DOUBLE CHECK VALVE (SEE DETAIL HEREON)
VALVE BOX (CARSON JUMBO BOX)
MASTER CONTROL VALVE
DRAIN VALVE
BRASS QUICK COUPLER VALVE (RAINBIRD 44LRC)
APPROVED VALVE BOX WITH BOLT DOWN
PVC PIPE (SCHEDULE 80)
FLOW SENSOR
PVC IRRIGATION MAIN (SCHEDULE 40)
SPRINKLER HEAD
REMOTE CONTROL VALVE
NOTES:
1. DO NOT ALLOW VAULT TO REST ON PIPE USE EXTENSIONS AS NECESSARY.
2. VALVE TO BE SET PLUMB & CENTERED IN VALVE BOX.
3. CONTRACTOR TO PROVIDE (1) EACH QCV KEY AND SWIVEL HOSE ELL PER PROJECT.
4. PROVIDE 6" DEPTH DRAIN ROCK.
DETAIL - POINT OF CONNECTION PLAN WITH PRV
NOT TO SCALE
CONDUIT FOR GCBL WIRING
CONDUIT FOR CONTROL WIRES
LINTER MODEL ACC-4800-PED
14" POWER CONDUIT: SIZE,
YPE, DEPTH PER LOCAL CODE
ROUND WIRE CONDUIT,
N. 1 1/2". GROUND PER
31C GUIDELINES
DESTAL BASE: CONCRETE
PREFABRICATED
FINISH GRADE
DETAIL -CONTROLLER WITH PEDESTAL
NOT TO SCALE
,TIC CONTROL VALVE
'LASTIC ISOLATION BALL VALVE
SAME SIZE AS CONTROL VALVE
/-VAULT FLUSH W/ FINISH GRADE
4" CLEAR
ZT
ii i� `% USE CARSON STANDARD VALVE BOX FOR 1"
N ������ VALVES,CARSON JUMBO VALVE BOX FOR 1-1/2"
z�,\
` VALVES,ANDSUPER-JUMBO VALVE BOX FOR 2"
00
VALVES. VAULT TO EXTEND MIN. 6" BELOW
VALVE. USE EXTENSIONS AS NECESSARY.
N
3" MIN.
SCHEDULE 40 PVC NIPPLE, TYP.
CLEAR
LENGTH AS REQUIRED
SCHEDULE 40 PVC 90
LATERAL LINE
BLULOCK & PVC CLASS 200
PVC UNIONS, TYP. USE 3" LENGTH NIPPLES BOTH SIDES OF UNION
VALVE NOTES:
1. DO NOT ALLOW VAULT TO REST ON PIPE.
2. ALL PIPE AND FITTINGS WITHIN VAULT TO BE SCH 40 PVC SAME SIZE AS OUTLET LATERAL.
3. ALL BOLT COVERS TO BE LOCKING TYPE, BOLT INSTALLED.
4. NO FEMALE ADAPTERS PERMITTED.
5. TEFLON TAPE ONLY. USE NO PIPE DOPE.
6. PROVIDE 6" WASHED DRAIN ROCK BENEATH VAULT.
FINI
COMPACTED
CLEAN BACKFILL
PVC LATERAL PIPE
PVC MAINLINE
FIELD CONTROL WIRES
TAPED TOGETHER AT
10" O.C. LOCATE 6"
FROM SIDE OF MAINLINE
COMPACTED CLEAN
BACK -FILL OR BEDDING
SAND, 6" DEPTH BELOW
PIPE
DETAIL - ZONE CONTROL VALVE
NOT TO SCALE
SOT BARRIER
)NCRETE SIDEWALK
I. IN SIDEWALK PLANTING STRIPS PLACE MAINLINE
NT 24" DEPTH AND 12" IN FROM SIDEWALK.
2. IN SIDEWALK PLANTING STRIPS PLACE
_ATERALS AT 12" DEPTH AND 18" IN FROM
31DEWALK.
BARE COPPER TRACE WIRE 12" GAUGE TAPED
ON MAINLINE 15" O.C.
MAINLINE AND LATERAL TRENCHING
UNDERGROUND LOCATOR SERVICE
C% L L BEFORE YOU DI C.1
ASPHALT, CONCRETE OR MASONRY PAVED SURFACE BY OTHERS
COMPACTED BACKFILL FROM NATIVE SOIL
1. SLEEVES REQUIRED UNDER ALL PAVED AREAS.
2. DUCT TAPE ENDS OF SLEEVE PIPE
3. SURVEYOR TO LOCATE ALL HARD SURFACES PRIOR
TO SLEEVE PIPE INSTALLATION.
— 5/8 MINUS CRUSHED ROCK BEDDING
PVC SLEEVE
SLEEVE TRENCHING
DETAIL - TRENCHING
NOT TO SCALE
PLAN VIEW
b
BALL VALVE
MAIN SHUT OFF
NOTES:
1. DO NOT ALLOW VAULT TO REST ON PIPE.
2. ALL PIPE AND FITTINGS TO BE 1 SIZE LARGER THAN COMPONENTS. USE REDUCING BUSHINGS.
3. ALL SCHEDULE 40 PVC PIPE AND FITTINGS FROM METER ASSEMBLY TO DOWN STREAM OF SECOND VAULT. NO FEMALE ADAPTERS
OR CLOSE NIPPLES.
4. INSTALLATION SHALL CONFORM WITH CITY OF ISSAQUAH STANDARD DETAIL NO. W-20. REVIEW CURRENT CITY STANDARDS FOR
REVISIONS.
5. TEST COCKS MUST HAVE 12" CLEARANCE.
1 6. FOR 3/4" & 1" DEVICES, USE TWO 'CARSON JUMBO' MODEL BOXES WITH THE BOTTOM BOX INVERTED. FOR 11/2" AND 2" DEVICES,
6'MINIMUM INSTALL TWO 'FOG TITE #2' REINFORCED CONCRETE BOXES OF THE SAME SIZE OR LARGER
BOTH SIDES 7. TEFLON TAPE ONLY. USE NO PIPE DOPE.
PRESSURE REDUCING VALVE
INSTALL SIDEWAYS
FLUSH WITH FINISH GRADE
DOUBLE CHECK VALVE
SCH. 80 PVC UNION, TYP.
P TQ oo Ir rwr �ro��
......,.,.,,. ,.00K, 12" DEPTH THROUGHOUT
DOUBLE CHECK ASSEMBLY WITH PRV AND MASTER VALVE
HEAD TO HEAD SPACING MAY BE DEFINED AS EACH HEAD'S SPRAY HITTING EACH
ADJACENT HEAD, ALL DIRECTIONS. FOR EXAMPLE, 12' RADIUS HEADS SHALL NOT BE
SPACED FURTHER THAN 12' ALL DIRECTIONS.
isr
H
z�
50
%> 0
— ST
HEAD TO HEAD LAYOUT NOTE: PLAN VIEW
ALL SHRUB HEADS TO BE IN SHRUB BED, AND TURF HEADS SHALL BE PLACED IN THE
TURF, 4" FROM EDGE OF BED.
NOTES:
1. USE 4" POP -UPS IN TURF AREAS AND 12" POP -UPS IN SHRUB OR GROUND COVER
AREAS.
DETAIL - HEAD LAYOUT
NOT TO SCALE
1 CONSTRUCTION RECORD DRAWINGS MEM 2/13/241 HHH SURVEYED: SCALE:
GLENN R. SPRAGUEA P.
L. S.
DESIGNED:
SHAHLA SOVVEV
DRAWN:
✓ACOB REEFF
ONE INCH
CHECKED:L AT L ALE
NOSEY SOL ORIO IF NOT ONEINCH
N 0. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY
UNDSFY S. SOL ORLO P. L. A
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
NOT TO SCALE
t.R C TY OF
RENTON
Namir
Planning/Building/Public Works Dept.
QUICK COUPLER VALVE
4" MASTER VALVE
VAULT PER SPECS
UNION, TYP.
CHANGE FROM SCH. 80 TO
SCH. 40 -2" MAIN LINE
WYE STRAINER WITH BLOWOFF INSTALLED
FLOW
TO FLOW SENSOR
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
SURVEYING
Bothell, Washington 98011 425.885.7877
R-417981
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CANOPY DATE:
2/13/24
4196L/NCOLNAVENE, RENTON, WA 98056 EIELDBOOK:
PAGE:
IRRIGATION DETAILS DRAWING NO L3.31
SHEET: OF:
9.3 107
O
O
Z
Q
CONSTRUCT/ON RECORD DRA WINGS