Loading...
HomeMy WebLinkAboutR-417981O Q FROM SOURCE IRRIGATION WATER METER (1") CONNECTION AND WATER METER GALVANIZED PIPE TO POINT OF CONNECTION VALVE BOX MUELLER SHUT OFF VALVE WILKENS Y5 100 STRAINER 1 1/2" PRESSURE REDUCING VALVE APPROVED DOUBLE CHECK VALVE (SEE DETAIL HEREON) VALVE BOX (CARSON JUMBO BOX) MASTER CONTROL VALVE DRAIN VALVE BRASS QUICK COUPLER VALVE (RAINBIRD 44LRC) APPROVED VALVE BOX WITH BOLT DOWN PVC PIPE (SCHEDULE 80) FLOW SENSOR PVC IRRIGATION MAIN (SCHEDULE 40) SPRINKLER HEAD REMOTE CONTROL VALVE NOTES: 1. DO NOT ALLOW VAULT TO REST ON PIPE USE EXTENSIONS AS NECESSARY. 2. VALVE TO BE SET PLUMB & CENTERED IN VALVE BOX. 3. CONTRACTOR TO PROVIDE (1) EACH QCV KEY AND SWIVEL HOSE ELL PER PROJECT. 4. PROVIDE 6" DEPTH DRAIN ROCK. DETAIL - POINT OF CONNECTION PLAN WITH PRV NOT TO SCALE CONDUIT FOR GCBL WIRING CONDUIT FOR CONTROL WIRES LINTER MODEL ACC-4800-PED 14" POWER CONDUIT: SIZE, YPE, DEPTH PER LOCAL CODE ROUND WIRE CONDUIT, N. 1 1/2". GROUND PER 31C GUIDELINES DESTAL BASE: CONCRETE PREFABRICATED FINISH GRADE DETAIL -CONTROLLER WITH PEDESTAL NOT TO SCALE ,TIC CONTROL VALVE 'LASTIC ISOLATION BALL VALVE SAME SIZE AS CONTROL VALVE /-VAULT FLUSH W/ FINISH GRADE 4" CLEAR ZT ii i� `% USE CARSON STANDARD VALVE BOX FOR 1" N ������ VALVES,CARSON JUMBO VALVE BOX FOR 1-1/2" z�,\ ` VALVES,ANDSUPER-JUMBO VALVE BOX FOR 2" 00 VALVES. VAULT TO EXTEND MIN. 6" BELOW VALVE. USE EXTENSIONS AS NECESSARY. N 3" MIN. SCHEDULE 40 PVC NIPPLE, TYP. CLEAR LENGTH AS REQUIRED SCHEDULE 40 PVC 90 LATERAL LINE BLULOCK & PVC CLASS 200 PVC UNIONS, TYP. USE 3" LENGTH NIPPLES BOTH SIDES OF UNION VALVE NOTES: 1. DO NOT ALLOW VAULT TO REST ON PIPE. 2. ALL PIPE AND FITTINGS WITHIN VAULT TO BE SCH 40 PVC SAME SIZE AS OUTLET LATERAL. 3. ALL BOLT COVERS TO BE LOCKING TYPE, BOLT INSTALLED. 4. NO FEMALE ADAPTERS PERMITTED. 5. TEFLON TAPE ONLY. USE NO PIPE DOPE. 6. PROVIDE 6" WASHED DRAIN ROCK BENEATH VAULT. FINI COMPACTED CLEAN BACKFILL PVC LATERAL PIPE PVC MAINLINE FIELD CONTROL WIRES TAPED TOGETHER AT 10" O.C. LOCATE 6" FROM SIDE OF MAINLINE COMPACTED CLEAN BACK -FILL OR BEDDING SAND, 6" DEPTH BELOW PIPE DETAIL - ZONE CONTROL VALVE NOT TO SCALE SOT BARRIER )NCRETE SIDEWALK I. IN SIDEWALK PLANTING STRIPS PLACE MAINLINE NT 24" DEPTH AND 12" IN FROM SIDEWALK. 2. IN SIDEWALK PLANTING STRIPS PLACE _ATERALS AT 12" DEPTH AND 18" IN FROM 31DEWALK. BARE COPPER TRACE WIRE 12" GAUGE TAPED ON MAINLINE 15" O.C. MAINLINE AND LATERAL TRENCHING UNDERGROUND LOCATOR SERVICE C% L L BEFORE YOU DI C.1 ASPHALT, CONCRETE OR MASONRY PAVED SURFACE BY OTHERS COMPACTED BACKFILL FROM NATIVE SOIL 1. SLEEVES REQUIRED UNDER ALL PAVED AREAS. 2. DUCT TAPE ENDS OF SLEEVE PIPE 3. SURVEYOR TO LOCATE ALL HARD SURFACES PRIOR TO SLEEVE PIPE INSTALLATION. — 5/8 MINUS CRUSHED ROCK BEDDING PVC SLEEVE SLEEVE TRENCHING DETAIL - TRENCHING NOT TO SCALE PLAN VIEW b BALL VALVE MAIN SHUT OFF NOTES: 1. DO NOT ALLOW VAULT TO REST ON PIPE. 2. ALL PIPE AND FITTINGS TO BE 1 SIZE LARGER THAN COMPONENTS. USE REDUCING BUSHINGS. 3. ALL SCHEDULE 40 PVC PIPE AND FITTINGS FROM METER ASSEMBLY TO DOWN STREAM OF SECOND VAULT. NO FEMALE ADAPTERS OR CLOSE NIPPLES. 4. INSTALLATION SHALL CONFORM WITH CITY OF ISSAQUAH STANDARD DETAIL NO. W-20. REVIEW CURRENT CITY STANDARDS FOR REVISIONS. 5. TEST COCKS MUST HAVE 12" CLEARANCE. 1 6. FOR 3/4" & 1" DEVICES, USE TWO 'CARSON JUMBO' MODEL BOXES WITH THE BOTTOM BOX INVERTED. FOR 11/2" AND 2" DEVICES, 6'MINIMUM INSTALL TWO 'FOG TITE #2' REINFORCED CONCRETE BOXES OF THE SAME SIZE OR LARGER BOTH SIDES 7. TEFLON TAPE ONLY. USE NO PIPE DOPE. PRESSURE REDUCING VALVE INSTALL SIDEWAYS FLUSH WITH FINISH GRADE DOUBLE CHECK VALVE SCH. 80 PVC UNION, TYP. P TQ oo Ir rwr �ro�� ......,.,.,,. ,.00K, 12" DEPTH THROUGHOUT DOUBLE CHECK ASSEMBLY WITH PRV AND MASTER VALVE HEAD TO HEAD SPACING MAY BE DEFINED AS EACH HEAD'S SPRAY HITTING EACH ADJACENT HEAD, ALL DIRECTIONS. FOR EXAMPLE, 12' RADIUS HEADS SHALL NOT BE SPACED FURTHER THAN 12' ALL DIRECTIONS. isr H z� 50 %> 0 — ST HEAD TO HEAD LAYOUT NOTE: PLAN VIEW ALL SHRUB HEADS TO BE IN SHRUB BED, AND TURF HEADS SHALL BE PLACED IN THE TURF, 4" FROM EDGE OF BED. NOTES: 1. USE 4" POP -UPS IN TURF AREAS AND 12" POP -UPS IN SHRUB OR GROUND COVER AREAS. DETAIL - HEAD LAYOUT NOT TO SCALE 1 CONSTRUCTION RECORD DRAWINGS MEM 2/13/241 HHH SURVEYED: SCALE: GLENN R. SPRAGUEA P. L. S. DESIGNED: SHAHLA SOVVEV DRAWN: ✓ACOB REEFF ONE INCH CHECKED:L AT L ALE NOSEY SOL ORIO IF NOT ONEINCH N 0. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY UNDSFY S. SOL ORLO P. L. A VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M NOT TO SCALE t.R C TY OF RENTON Namir Planning/Building/Public Works Dept. QUICK COUPLER VALVE 4" MASTER VALVE VAULT PER SPECS UNION, TYP. CHANGE FROM SCH. 80 TO SCH. 40 -2" MAIN LINE WYE STRAINER WITH BLOWOFF INSTALLED FLOW TO FLOW SENSOR CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING SURVEYING Bothell, Washington 98011 425.885.7877 R-417981 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CANOPY DATE: 2/13/24 4196L/NCOLNAVENE, RENTON, WA 98056 EIELDBOOK: PAGE: IRRIGATION DETAILS DRAWING NO L3.31 SHEET: OF: 9.3 107 O O Z Q CONSTRUCT/ON RECORD DRA WINGS