PSE STREET LIGHTING SCOPE OF WORK
ILLUMINATION POLE SCHEDULE (INSTALLED BY PSE STREET LIGHTING)
LUM.
STREET
STATION
OFFSET
MOUNTING
ARM
POLE
LUMINAIRE TYPE
WATTAGE
/TYPE
INITIAL
COMMENT
POLE NO.
HEIGHT
LENGTH
LUMENS
0P 1
LINCOLN AVE NE
EX
EX
EX 28'
EX 8'
EX
GE EVOLVE
1 1 1 W
13, 000
REPLACE EXISTING FIXTURE WITH NEW LUMINAIRE.
ERLH-0-13-C3-40
LED
TO BE INSTALLED BY PSE STREET LIGHTING.
0ALLEY
3
61 +50.5
11.5LT
14
NSA
PED. STRAIGHT
*
CYCLONE PRESTIGE
CY1 1 TA-VS3AR-2-34-3K
34W
3, 664
NEW LIGHT POLE AND LUMINAIRE TO BE INSTALLED
ALUMINUM
LED
BY PSE STREET LIGHTING.
*MATCH POLE TYPE USED FOR CITY OWNED PEDESTRIAN POLES. SEE CITY OF RENTON STANDARD PLAN 116.1.
PSE STREET LIGHTING CONSTRUCTION NOTE
PSEf EXISTING UTILITY POLE TO REMAIN. REPLACE EXISTING ROADWAY SCALE FIXTURE WITH NEW LUMINAIRE PER ILLUMINATION POLE SCHEDULE, THIS SHEET. LUMINAIRE
SHALL BE INSTALLED BY PSE STREET LIGHTING.
FURNISH AND INSTALL NEW PEDESTRIAN SCALE POLE AND LUMINAIRE PER ILLUMINATION POLE SCHEDULE, THIS SHEET. POLE AND LUMINAIRE SHALL BE INSTALLED BY
SE2 PSE STREET LIGHTING.
PSE STREET LIGHTING GENERAL NOTE
1. PROJECT CONTRACTOR SHALL COORDINATE WITH PSE STREET LIGHTING TO SCHEDULE INSTALLATION, INCLUDING COMPLETING ALL FORMS, PAYMENT OF ALL FEES,
ETC. ASSOCIATED WITH THE INSTALLATION. PSE STREET LIGHTING SHALL FURNISH AND INSTALL ALL MATERIALS BY CONTRACT WITH THE DEVELOPER.
AS-BUILTS CERTIFICATION:
I HEREBY CERTIFY THAT THE AS -BUILT MEASUREMENTS SHOWN
HEREON ARE TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE
AND BELIEF AS SURVEYED IN THE FIELD IN JANUARY 29th, 2024
T 03-07-2024
NAME 35635
LICENSE #
DATE
03-07-20241
ASBUILT NOTE
THE ASBUILT INFORMATION DEPICTED ON THESE
PLANS IS BASED UPON FIELD SURVEY
INFORMATION PROVIDED BY CORE DESIGN AND
SUPPLEMENTED BY SITE CONTRACTOR,
GOODFELLOW BROTHERS, ON JANUARY 29TH,
2024. GOODFELLOW BROTHERS INDICATES THAT
THE DATA PROVIDED TO CORE DESIGN
ACCURATELY REPRESENTS FILED CONDITIONS ON
THE DATE OF THEIR SURVEY. CORE DESIGN HAS
REVIEWED THE INFORMATION PROVIDED FOR
GENERAL CONFORMANCE WITH THE DESIGN
CONCEPT, AND TO THE BEST OF OUR KNOWLEDGE
THE INFORMATION IS IN ACCORDANCE WITH THE
OBSERVED FIELD CONDITIONS.
F
UNDERGROUND LOCATOR SERVICE
CALL BEFORE YOU DIG.
811
1 1 CONSTRUCTION RECORD DRAWINGS
"If
REVISION
M E M 2/ 13/24 H H H SURVEYED:
DESIGNED:
B VL
DRAWN:
B VL
CHECKED:
GMD
BY DATE APPR APPROVED:
CTB
E
4
N I
1 I 1 I
I EX
I DRIVEWAY
I I=
a �
4 I Q)
"f' n
ILQ
I \ 3 I
4
\ 1 4 0�
\ 5 D �V '
�r
I
ILLUMINATION CONSTRUCTION NOTES
Q0
OCONSTRUCT
FOUNDATION PER CITY OF RENTON STANDARD PLAN 116.1.
FURNISH AND INSTALL NEW POLE, LUMINAIRE, JUNCTION BOX, AND CONDUIT
PER ILLUMINATION POLE SCHEDULE, SHEET IL-03, AND CITY OF RENTON
�M
"V
STANDARD PLANS 1 16.1, 119, 120, AND 121.
O
20
EXISTING UTILITY POLE MOUNTED LUMINAIRE TO REMAIN.
O
OCONSTRUCT
SERVICE CABINET FOUNDATION PER CITY OF RENTON STANDARD
PLAN 126.1. FURNISH AND INSTALL NEW SERVICE CABINET ON NEW
N
FOUNDATION PER CITY OF RENTON STANDARD PLANS 122.1 AND 126.1.
V
OTHE
4
POWER SOURCE LOCATION WAS NOT KNOWN AT THE TIME OF PLAN
PREPARATION. THE CONTRACTOR SHALL COORDINATE WITH PSE TO IDENTIFY A
LOCATION FOR 1201240 VOLT SINGLE PHASE POWER SOURCE CONNECTION
INCLUDING COMPLETING ALL FORMS/APPLICATIONS AND PAYMENT OF ALL
ASSOCIATED FEES. PSE SHALL MAKE FINAL CONNECTION TO THE POWER
SOURCE. THE CONTRACTOR SHALL ASSUME 500 FEET OF TRENCHING TO
CONNECT TO POWER SOURCE FOR BIDDING PURPOSES.
OCONSTRUCT
FOUNDATION PER CITY OF RENTON STANDARD PLAN 117.1.
FURNISH AND INSTALL NEW POLE, LUMINAIRE, JUNCTION BOX, AND CONDUIT
PER ILLUMINATION POLE SCHEDULE, SHEET IL-02, AND CITY OF RENTON
STANDARD PLANS 1 17.1, 119, 120, AND 121.
T-417904
SCALE:
VERTICAL: NAVD 1988
• CITY 0 F
HORIZONTAL: NAD 1983/183/1991
%R
1; 1 RENTON
ONE INCH DATU M Nbov
AT FULL SCALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
SCALE ACCORDINGLY
ILLUMINATION WIRING SCHEDULE
RACEWAY
CONDUIT
IZ DUIT
ILLUM.
#8
SERVICE
POWER
EQUIP.
GROUND
N0.
1
2" SCH40 PVC
2
1
2
2" SCH80 PVC
2
1
3
3" SCH80 PVC
3
4
2" SCH40 PVC
4
1
* EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR
LARGER THAN THE LARGEST WIRE SIZE IN THE
CONDUIT.
SEE SHEET IL-03 FOR:
• ILLUMINATION GENERAL NOTES
• ILLUMINATION WIRING DIAGRAM
• BREAKER SCHEDULE
• PHOTOMETRIC CALCULATION SUMMARY
• ILLUMINATION POLE SCHEDULE
.Miiiiiiiiiw Z�
15 60
0 30 90
SCALE IN FEET
ILLUMINATION LEGEND
EX NEW DESCRIPTION
m r JUNCTION BOX TYPE 1, 2
ROADWAY SCALE LUMINAIRE POLE
COMBINED PED/ROADWAY SCALE
LUMINAIRE POLE
UTILITY POLE WITH LUMINAIRE
PEDESTRIAN SCALE LUMINAIRE POLE
- - - - - CONDUIT/CONDUCTOR
® SERVICE CABINET
O CONSTRUCTION NOTE
LUMINAIRE NO.
WIRE NOTE
�MERT
of wAsy° ��i�9TENW
"�Fic z� Transportation Engineering NorthWest
ASS RIVAL ECG\ Transportation Planning I Design I Traffic Impact & Operations
1 1400 SE 8th Street, Suite 200, Bellevue, WA 98004 1 Office (425) 889-6747
0,3107120241 Project Contact: Glen DuBreuil
Phone: 425-250-0582
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CANOPY
4196 L/NCOLNAVENE, RENTON, WA 98056
ILLUMINATION PLAN
N
N
O
O
O
V
M
O
O
1
O
Z
DATE:
0JI07124 V
FIELDBOOK:
PAGE:
DRAWING NO:
IL-02
SHEET: OF:
105 107