HomeMy WebLinkAboutMFP22003041.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP22003041
IVR Number: 22003041
Permit Information
Permit Name: Comcast Cable Franchise Permit-JB0000845743 V1
Address/Location:06/13/2022Application Date:0518500010Parcel Number: 1252 N 42ND PL
Permit Type:07/05/2022Issue Date:Franchise
Permit Work Class:07/05/2023Expiration Date:Minor Utility
Job Number: JB0000845743Franchise Type:Cable
Description: Comcast JB0000845743 V1. TIE INTO SPLICE CASE SP.WAKV.0426 WITH 48CT FIBER. PLACE 48CT SHEATH
200' STORAGE @ RISER. PULL 48 CT FIBER IN EXISTING CONDUIT, (TYPICAL). PLACE 48CT SHEATH 200'
STORAGE EVERY 1500'. UPGRADE DOG HOUSE TO TIGER HOUSE AND PLACE 1X2 RPHY NODE. SPLICE INTO
EXISTING SPLICE CASE; WAKVD02K01_SP0120.WAKV WITH 48CT FIBER. REPLACE / RE LASH DAMAGED COAX.
UPGRADE (1) VAULT TO DOGHOUSES. RESTORATION PER CITY OF RENTON STANDARDS.
Contacts
Name Address PhoneTypeBilling
Annie Robertson
Cannon Construction LLC
406 Porter Way
Milton, WA 98354
ApplicantX
Andrew Parker
Comcast
410 Valley Ave NW, Suite 12 Bldg C
Puyallup, WA 98371
B: (253) 225-0596Contact
Andrew Parker
comcast
410 Valley Ave NW
Puyallup, WA 98371
B: (253) 864-4249Contact
Michael Cannon
Cannon Constructors Inc
406 Porter Way
Milton, WA 98354
B: (253) 922-2787Contractor
Business License Number: 41539Construction Contractor: CANNOCL791JK
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Laurie Dietz
Comcast - Billing
1701 John F. Kennedy Blvd.
Philadelphia, PA 19103
H: (425) 741-5733Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 of 1 | Published: 1/2/2019
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 1/2/2019
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site
Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee
for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Description of Work:
Please check all that apply:
☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street
☐ Open Trench ☐ Bore # of feet:
Contractor Name: Phone:
State Contractors License #: City of Renton Business License #:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth
under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at
$125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
Comcast Cable Communications Management
JB0000845743
Andrew Parker
253-225-0596
andrew_parker2@comcast.com
N 43DR ST & LK WASHINTON BLVD WAKVD0K00 1X2-WAKVD02G00
TIE INTO SPLICE CASE SP.WAKV.0426 WITH 48CT FIBER.
-PLACE 48CT SHEATH 200' STORAGE @ RISER. -PULL 48 CT FIBER IN EXISTING CONDUIT, (TYPICAL).
-PLACE 48CT SHEATH 200' STORAGE EVERY 1500'. -UPGRADE DOG-HOUSE TO TIGER-HOUSE AND PLACE 1X2 RPHY NODE.
Cannon Construction LLC - David Standring 253-922-2787
601590363 20838
06/13/2022
MFP22003041
Scott Warlick 7/5/2022
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
DEPARTMENT OF PUBLIC WORKS
Page 1 of 3 | Published: 10/27/2021
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 10/27/2021
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control
plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2. The following items are all required for submittal of the TCP Application:
☐ Electronic Copy of the TCP Application
☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:
Include map(s) showing the location of the project and work area.
Be legible lettering and clear, contrasting, symbols of viewing or printing.
Must indicate street names, and north arrow and scale.
Types of plans required:
o Work hour plan – show all mobility impacts during construction hours.
o Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
o Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
o Pedestrian access/detour plan, if applicable.
- Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the
Evergreen Safety Council.
3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
Project Name: Permit #:
Site Address:
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Construction Company:
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip:
Description of Work:
Approval By: _________________________________________________ Date:____________________
Transportation Engineering
T2B/D - WAKVD02K00 1X2 - WAKVD02G00 2X4 (RN25A 2X2) - RF
N 43RD ST & LAKE WASHINGTON BLVD N RENTON , WA 98056
9/12/2022 9/18/2022 0800 1600
Cannon Construction LLC
Andrew Parker 253-225-0596
TIE INTO SPLICE CASE SP.WAKV.0426 WITH 48CT FIBER. -PLACE 48CT SHEATH 200' STORAGE @ RISER.
-PULL 48 CT FIBER IN EXISTING CONDUIT, (TYPICAL). -PLACE 48CT SHEATH 200' STORAGE EVERY 1500'.
X
X
MFP22003041
Monday - Friday 8:00AM - 3:00PM
Scott Warlick CED 7/5/2022
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 3 | Published: 10/27/2021
PERMIT HOLDER AGREES TO ALL THE FOLLOWING:
Must have approved Traffic Control Plan (TCP) prior to commencing the work.
Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time,
with the least possible inconvenience or delay to pedestrians.
WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the
traveled way.
Comply with all traffic regulations of the City of Renton and the State of Washington.
Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street
and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control
Devices.
Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends
and holidays) prior to starting any work.
Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum
of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a
temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a
minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140
with any questions.
Any lane or street closures not in conformance with the approved traffic control plan and/or without notification
of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at
thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles and
the acts of the Permit Holder’s agents and employees.
The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in
such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for
legal counsel chosen by the City to defend against same.
Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
All permit conditions shall be met.
NOTES:
Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to WSDOT.
Approved Temporary Traffic Control Plan must be at the work site during work hours.
Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery
road conditions during work and non-work hours.
Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company
logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous
place on the vehicle or equipment.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 3 of 3 | Published: 10/27/2021
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555
NE 2nd Street).
I certify that the information on this application and within the submittal documents are accurate to the best of my
knowledge and I acknowledge all the requirements on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
4350
1114 1120 1126 1210 1216 1222 1228 1234 1240
1246 1252
1109 1115 1121
1211 1217 1223 1229 1235 1241
12041132
1116
1122
1128
1111
1117
1123
1129
1219
1225 1231
1213
1207
1201
0
0
0
1105
EOPEOPEOPEOPEOPEOPEOPEOP
EOPEOPEOP
EOP
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP
EOP
EOP
EOP EOP EOP EOP EOP EOPEOP
EOPEOPEOPEOP EOP EOP
EOP
EOP
EOPEOPEOPEOPEOPEOPEOPEOP
EOP
EOP
EOP
EOP EOP EOPEOPEOPEOP
EOP EOP
EOP
EOP
EOP EOP EOP EOP EOP EOP
EOP
EOP
EOP
EOP EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPR25'
LAK
E
W
A
S
HI
N
G
T
O
N
BL
V
D
N
LAKE WASHINGTON BLVD NN 42ND PLHA
Z
E
LW
OO
D
LN
ASPHALTASPHALTSIDEWALK SIDEWALK SIDEWALK
SIDE
WA
LK SIDEWALK
SIDE
WALK
SIDEWALK
SIDEWALKSIDEW
A
L
K SIDEW
A
LK
SIDEWA
LK
SIDE
WAL
K
SIDEW
A
LK
SIDEWALK
SIDE
WAL
K
SIDEWALKSIDEWAL
K
SIDE
WAL
KSIDEW
ALK
SIDEWAL
K
SIDEWAL
K SIDEWALKSIDEWALK SIDEWALKSIDEWALKSIDEWALKSIDEWALK
SIDEWALK
SIDEWALK SIDEWALK
SIDEW
A
L
K
SIDE
W
A
L
K
SID
E
W
A
L
K
SIDEWAL
K
LANDSCAPE
LANDSCAPELANDSCAPE
LANDSCAPELANDSCAP
E
LANDSCAPE
LANDSCAPE LANDSCAPE
LANDSCAPE LANDSCAPE
LANDSCAPE LANDSCAPE
LANDSCAPE
LANDSCAPE
LANDSCAPE
LANDSCAPE
LAND
S
C
A
P
E
LAN
D
S
C
A
P
E
GRASS
GRASS
GRASS
GRASS
LANDSCAPE LANDSCAPELANDSCAPELANDSCAPELAND
S
C
A
P
E
DRIVEWAY
DRIVEWA
Y
DRIVEWAY
DRIVEW
A
Y
DRIVE
W
A
Y
DRIVEWA
Y
DRIVEWA
Y
DRIVEWA
Y
DRIV
E
WAY
DRIVE
W
A
Y
DRIVEW
A
Y
DRIVEW
A
Y DRIVEWAY DRIVEWAY DRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYASPHALT
ASPHALT ASPHALTASPHALT
ASPHALT
ASPHALT
ASPHALTASPHAL
T
ASP
H
A
L
T
ASP
H
A
L
T
ASPH
A
L
T
ASP
H
A
L
T
ASPH
A
L
T
ASPH
A
L
T
ASPHALTASPH
A
LT
ASPHALTASPHALT
ASPHALTASPHAL
T
ASPHALTASPHALT
ASPHA
L
T
ASPHA
L
T
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT ROWROW
ROW
RO
W
RO
W
ROW
ROWROW
ROW
ROWROWROWROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW ROWROWROWROWROWROW
ROW ROW ROW ROW ROW ROW
ROW ROW
ROW ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROWROWROWROWROWROWROWROWROWROWROW
XXXFL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
WT
P PFL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FLFL
FL
FL FL
FL FL
FL
FL FL
FL
FL
FL
FL
FL
FL
FL FL
FL FL
FL FL
FL
FL
FL
FL FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL FL
FL FL
FL FL
FL
FL
FL FL
FL FL
FL FL
FL FL
FL
FL FL
FL FL
FL FL
FL
FL FL
FL FL
FL
FL
FL
FL
FL
FL
FLFL
FL
FL
FL
FL
FL
N 42ND PL
N 41ST PLPARKING
PARKING
PARKING
PARKING
PARKING
WTASPH
A
L
T EOPEOPEOP
EOP
EOP
EOP
WT XXXFL
FL
FL FL FL
FL
FL
FL
FL
FLFL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
R2-1
FLAGGER
FLAGGER
X
X
X
FLAGGER
LANDSCAPE
GRASS
GRASS
GRASS
GRASS
GRASS
GRASS
GRASS
GRASS
GRASS
SIGN SPACING = X (FEET)
FREEWAYS & EXPRESSWAYS 50/70 MPH 1500' +/-(OR AS PER MUTCO)
RURAL HIGHWAYS 60/65 MPH 800' +/-
RURAL ROADS 45/55 MPH 500' +/-
RURAL ROADS & URBAN ARTERIALS 35/40 MPH 350' +/-
RURAL ROADS & URBAN ARTERIALS
RESIDENTAL & BUSINESS DISTRICTS
URBAN STREETS 25 MPH OR LESS 100' +/-
25/30 MPH 200' +/-
ALL SIGNS ARE 48"x48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
(1) ALL SIGN SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT GRADE
INTERSECTIONS AND DRIVEWAYS.
(2) THE SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
DISCLAIMER
All traffic control setups, sign spacing, and procedures will conform
to the specifications stated in the federal Manual on Uniform Traffic
Control Devices (M.U.T.C.D)
Cities and various municipalities may have also adopted specialized
guidelines for traffic control within their jurisdiction. It is the
responsibility of the on-site traffic control personnel to verify if any
special conditions exist.
TRAFFIC CONTROL ADDITIONAL NOTES
-For aerial work, there will be a moving traffic control setup
-Will coordinate with businesses that will be affected by
construction
-Will have spotter on site to escort pedestrians through
work zone
-All work will stop while pedestrians are escorted through
work zones
-Will have no more than two work areas active at a time
SITE NOTES
-Maintain driveway access at all times
-Place temporary "NO PARKING" signs at least
72 hours prior to work
-Sidewalks to remain open during road work
unless noted otherwiseFLAGGER SPOTTERWT
LEGEND
Work Vehicle Work Area
Flagger Spotter
N
OF
APPROVED BY:
PROJECT CODE:
DRAWN BY:
DATE:
SCALE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCTCP NODE SEGMENTATION1JBLSPLIP PERMIT INTO MUTIPLE PARTS6/3/2022JB0000845743000
4
1
CS
JBL
2/11/2022
NTSRENTON, WA 98056N 43RD ST & LK WASHINGTON BLVD NWAKVD02G00 1X2-WAKVD0G00 2X4 (RN25A)-RF17-050
10 105 150 205 270 450 500 550 ---
11 115 160 225 295 495 550 605 660 --
12 125 180 245 320 540 600 660 720 780 840
LANE
WIDTH 25 30 35 40 45 50 55 60 65 70
MINIMUM TAPER LENGTH IN FEET = L
POSTED SPEED LIMIT (MPH)
SPEED 25 30 35 45 50 55
155 200 250 360 425 495 570
LONGITUDINAL BUFFER SPACE = B
LENGTH
40
305
60 65 70
780 840
THE DESIGNED TRAFFIC CONTROLS CONTAINED WITHIN
THIS TCP WILL NOT BE IMPLEMENTED UNTIL APPROVED
BY THE PUBLIC AUTHORITY HAVING JURISDICTIONCONTROL TYPE:[AERIAL WORK]FLAGGING 2-LANE ROADSITE SPECIFIC TRAFFIC CONTROL PLAN
MFP22003041
1234 1240
1246 1252 EOPEOPEOPEOPEOPEOPEOPEOPEOPEOP
EOP
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP EOP EOPEOPEOPEOPPN 42ND PLSIDEWALK SIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDE
W
A
L
K SIDEWALKSIDEWALKSIDEW
A
L
K
SID
E
W
A
L
K
SID
E
W
A
L
K SIDEWALKLANDSCAPELANDSCAPELANDSCAPELANDSCAPE
LA
N
D
S
C
A
P
E
LA
N
D
S
C
A
P
E
GRASS
GRASS
DRIVEWAYDRIVEWAYASPHALTASPHALTAS
P
H
A
L
T
AS
P
H
A
L
T
AS
P
H
A
L
T
AS
P
H
A
L
T
ASPHALTASPHALTASPH
A
L
T
ASPH
A
L
T
ASPHALT
ASPHALT
ROWROW ROWROW ROWROWROWROWROWROWROW
ROWROW
ROWROW
ROWROW
ROWROW
ROWROW
ROWROW
ROWROW
ROWROWROWROWROWROWROWROWROWROWROWROW ROWROW
ROWROW
ROWROW
ROWROW
ROW
ROWROWROW
ROWROWROW XXWTPFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLXXR2-1
FLFLFL22'
32'
SPOTTER
6 DEVICE MIN50'-100'SIGN SPACING = X (FEET)
FREEWAYS & EXPRESSWAYS 50/70 MPH 1500' +/-(OR AS PER MUTCO)
RURAL HIGHWAYS 60/65 MPH 800' +/-
RURAL ROADS 45/55 MPH 500' +/-
RURAL ROADS & URBAN ARTERIALS 35/40 MPH 350' +/-
RURAL ROADS & URBAN ARTERIALS
RESIDENTAL & BUSINESS DISTRICTS
URBAN STREETS 25 MPH OR LESS 100' +/-
25/30 MPH 200' +/-
ALL SIGNS ARE 48"x48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
(1) ALL SIGN SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT GRADE
INTERSECTIONS AND DRIVEWAYS.
(2) THE SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
DISCLAIMER
All traffic control setups, sign spacing, and procedures will conform
to the specifications stated in the federal Manual on Uniform Traffic
Control Devices (M.U.T.C.D)
Cities and various municipalities may have also adopted specialized
guidelines for traffic control within their jurisdiction. It is the
responsibility of the on-site traffic control personnel to verify if any
special conditions exist.
TRAFFIC CONTROL ADDITIONAL NOTES
-For aerial work, there will be a moving traffic control setup
-Will coordinate with businesses that will be affected by
construction
-Will have spotter on site to escort pedestrians through
work zone
-All work will stop while pedestrians are escorted through
work zones
-Will have no more than two work areas active at a time
SITE NOTES
-Maintain driveway access at all times
-Place temporary "NO PARKING" signs at least
72 hours prior to work
-Sidewalks to remain open during road work
unless noted otherwiseFLAGGER SPOTTERWT
LEGEND
Work Vehicle Work Area
Flagger Spotter
N
OF
APPROVED BY:
PROJECT CODE:
DRAWN BY:
DATE:
SCALE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCTCP NODE SEGMENTATIONJB0000845743000
4
2
CS
JBL
2/11/2022
NTSRENTON, WA 98056N 43RD ST & LK WASHINGTON BLVD NWAKVD02G00 1X2-WAKVD0G00 2X4 (RN25A)-RF17-050
10 105 150 205 270 450 500 550 ---
11 115 160 225 295 495 550 605 660 --
12 125 180 245 320 540 600 660 720 780 840
LANEWIDTH 25 30 35 40 45 50 55 60 65 70
MINIMUM TAPER LENGTH IN FEET = L
POSTED SPEED LIMIT (MPH)
SPEED 25 30 35 45 50 55
155 200 250 360 425 495 570
LONGITUDINAL BUFFER SPACE = B
LENGTH
40
305
60 65 70
780 840
THE DESIGNED TRAFFIC CONTROLS CONTAINED WITHIN
THIS TCP WILL NOT BE IMPLEMENTED UNTIL APPROVED
BY THE PUBLIC AUTHORITY HAVING JURISDICTIONCONTROL TYPE:[UNDERGROUND WORK]SHOULDER WORK 2-LANE ROADSITE SPECIFIC TRAFFIC CONTROL PLAN
MFP22003041
1114 1126 1210 1216 1222 1228
1109 1115 1121
1211 1217
1223
1229
1204
1132
1219
1225
0
0
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP EOP EOP EOPEOP
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPDH
ASPHALTASPHALTSIDEWALK SIDEWALK
SIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALK
SIDEWALK
SIDEWALK
LANDSCAPE
LANDSCAPELANDSCAPE
LANDSCAPE
LANDSCAPE LANDSCAPE
LANDSCAPELANDSCAPEDRIVE
W
A
Y DRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ROWROWROWROWROWROW
ROW ROW ROW ROW
ROWROWROWROWROWROWROWROWROWROW
P
XXWTPARKING XX
R2-1
N 42ST PL
N 41ST PLDRIVEWAYDRIVEWAY22'
32'
SPOTTER6 DEVICE MIN50'-100'SPOTTER
SIGN SPACING = X (FEET)
FREEWAYS & EXPRESSWAYS 50/70 MPH 1500' +/-(OR AS PER MUTCO)
RURAL HIGHWAYS 60/65 MPH 800' +/-
RURAL ROADS 45/55 MPH 500' +/-
RURAL ROADS & URBAN ARTERIALS 35/40 MPH 350' +/-
RURAL ROADS & URBAN ARTERIALS
RESIDENTAL & BUSINESS DISTRICTS
URBAN STREETS 25 MPH OR LESS 100' +/-
25/30 MPH 200' +/-
ALL SIGNS ARE 48"x48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
(1) ALL SIGN SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT GRADE
INTERSECTIONS AND DRIVEWAYS.
(2) THE SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
DISCLAIMER
All traffic control setups, sign spacing, and procedures will conform
to the specifications stated in the federal Manual on Uniform Traffic
Control Devices (M.U.T.C.D)
Cities and various municipalities may have also adopted specialized
guidelines for traffic control within their jurisdiction. It is the
responsibility of the on-site traffic control personnel to verify if any
special conditions exist.
TRAFFIC CONTROL ADDITIONAL NOTES
-For aerial work, there will be a moving traffic control setup
-Will coordinate with businesses that will be affected by
construction
-Will have spotter on site to escort pedestrians through
work zone
-All work will stop while pedestrians are escorted through
work zones
-Will have no more than two work areas active at a time
SITE NOTES
-Maintain driveway access at all times
-Place temporary "NO PARKING" signs at least
72 hours prior to work
-Sidewalks to remain open during road work
unless noted otherwiseFLAGGER SPOTTERWT
LEGEND
Work Vehicle Work Area
Flagger Spotter
N
OF
APPROVED BY:
PROJECT CODE:
DRAWN BY:
DATE:
SCALE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCTCP NODE SEGMENTATIONJB0000845743000
4
3
CS
JBL
2/11/2022
NTSRENTON, WA 98056N 43RD ST & LK WASHINGTON BLVD NWAKVD02G00 1X2-WAKVD0G00 2X4 (RN25A)-RF17-050
10 105 150 205 270 450 500 550 ---
11 115 160 225 295 495 550 605 660 --
12 125 180 245 320 540 600 660 720 780 840
LANEWIDTH 25 30 35 40 45 50 55 60 65 70
MINIMUM TAPER LENGTH IN FEET = L
POSTED SPEED LIMIT (MPH)
SPEED 25 30 35 45 50 55
155 200 250 360 425 495 570
LONGITUDINAL BUFFER SPACE = B
LENGTH
40
305
60 65 70
780 840
THE DESIGNED TRAFFIC CONTROLS CONTAINED WITHIN
THIS TCP WILL NOT BE IMPLEMENTED UNTIL APPROVED
BY THE PUBLIC AUTHORITY HAVING JURISDICTIONCONTROL TYPE:[UNDERGROUND WORK]SHOULDER WORK 2-LANE ROADSITE SPECIFIC TRAFFIC CONTROL PLAN
MFP22003041
4101
4107
4113
4119
4125
4151
4157
4163
1002
1008
1003
1009
1015
1021
4122
4118
4112
4106
0EOPEOPEOPEOPEOP
EOPEOPEOPEOPEOPEOPEOPEOP
EOPEOPEOPEOPEOPEOPEO
P
EOP
EOP
EOP
WILLIAMS AVE NASPHALTASPHALTSI
D
E
W
A
L
K
SIDEWALKSIDE
W
A
L
K
SIDE
W
A
L
K
SIDE
W
A
L
KSIDEWALK
SIDEWALK SIDEWALKSIDEWALKSIDEWALKSIDE
W
A
L
K
SIDEW
A
L
K
LAND
S
C
A
P
E
LAN
D
S
C
A
P
E
LANDSCAPE
LANDSCAPE
LANDSCAPE
LANDSCAPE
LANDSCAPELANDSCAPE
DRIVEWAY
DRIVEWAY DRIVEWAY
DRIVEWAY
DRIVEWAYDRIVEWAY DRIV
E
W
A
Y
DRIV
E
W
A
Y
DRIV
E
W
A
Y
DRIV
E
W
A
Y
DRIVEWAY
DRIV
E
W
A
Y
DRIVEWAY
DRIV
E
W
A
Y
ASPHALTASPHALTASPHALT
ASPHALT
ASP
H
A
L
T
ASP
H
A
L
TROW
ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW
ROW
ROW
ROW
ROW
ROWROWROW
ROWROWROWROWROWROWROWROWROWROWROWROWROWROWXXWTDRIVEWAYXP
P
XV
R2-1XWT
SIDEWALKSIDEWALK
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIV
E
W
A
Y
22'
32'
SPOTTER
6 DEVICE MIN50'-100
'
22'
SPOTTER
SIGN SPACING = X (FEET)
FREEWAYS & EXPRESSWAYS 50/70 MPH 1500' +/-(OR AS PER MUTCO)
RURAL HIGHWAYS 60/65 MPH 800' +/-
RURAL ROADS 45/55 MPH 500' +/-
RURAL ROADS & URBAN ARTERIALS 35/40 MPH 350' +/-
RURAL ROADS & URBAN ARTERIALS
RESIDENTAL & BUSINESS DISTRICTS
URBAN STREETS 25 MPH OR LESS 100' +/-
25/30 MPH 200' +/-
ALL SIGNS ARE 48"x48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
(1) ALL SIGN SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT GRADE
INTERSECTIONS AND DRIVEWAYS.
(2) THE SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
DISCLAIMER
All traffic control setups, sign spacing, and procedures will conform
to the specifications stated in the federal Manual on Uniform Traffic
Control Devices (M.U.T.C.D)
Cities and various municipalities may have also adopted specialized
guidelines for traffic control within their jurisdiction. It is the
responsibility of the on-site traffic control personnel to verify if any
special conditions exist.
TRAFFIC CONTROL ADDITIONAL NOTES
-For aerial work, there will be a moving traffic control setup
-Will coordinate with businesses that will be affected by
construction
-Will have spotter on site to escort pedestrians through
work zone
-All work will stop while pedestrians are escorted through
work zones
-Will have no more than two work areas active at a time
SITE NOTES
-Maintain driveway access at all times
-Place temporary "NO PARKING" signs at least
72 hours prior to work
-Sidewalks to remain open during road work
unless noted otherwiseFLAGGER SPOTTERWT
LEGEND
Work Vehicle Work Area
Flagger Spotter
N
OF
APPROVED BY:
PROJECT CODE:
DRAWN BY:
DATE:
SCALE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCTCP NODE SEGMENTATIONJB0000845743000
4
4
CS
JBL
2/11/2022
NTSRENTON, WA 98056N 43RD ST & LK WASHINGTON BLVD NWAKVD02G00 1X2-WAKVD0G00 2X4 (RN25A)-RF17-050
10 105 150 205 270 450 500 550 ---
11 115 160 225 295 495 550 605 660 --
12 125 180 245 320 540 600 660 720 780 840
LANE
WIDTH 25 30 35 40 45 50 55 60 65 70
MINIMUM TAPER LENGTH IN FEET = L
POSTED SPEED LIMIT (MPH)
SPEED 25 30 35 45 50 55
155 200 250 360 425 495 570
LONGITUDINAL BUFFER SPACE = B
LENGTH
40
305
60 65 70
780 840
THE DESIGNED TRAFFIC CONTROLS CONTAINED WITHIN
THIS TCP WILL NOT BE IMPLEMENTED UNTIL APPROVED
BY THE PUBLIC AUTHORITY HAVING JURISDICTIONCONTROL TYPE:[UNDERGROUND WORK]SHOULDER WORK 2-LANE ROADSITE SPECIFIC TRAFFIC CONTROL PLAN
MFP22003041
SHEET INDEX:
1 - COVER SHEET
2 -GENERAL NOTES
3 -LEGEND
4 -DESIGN
THIS IS PROPRIETARY INFORMATION AND NOT MEANT FOR GENERAL PUBLICATION. ALL RIGHTS RESERVED BY CANNON COMPANIES
CONTACTS:
PROJECT MAP:
*ALL FOOTAGES AND MATERIALS ARE ESTIMATED
N
BILL OF MATERIALS*:
RE-LASH =
OVER-LASH =
NEW UNDERGROUND =
EXISTING UNDERGROUND =
RISER (1)=
TOTAL ROW FOOTAGE =
0 FT.
350 FT.
0 FT.
1944 FT.
25 FT.
2319 FT.
CANNON COMPANIES
SAFETY | QUALITY | INTEGRITY | TEAMWORK
Connecting The Future Since 1985
COMCAST
N 43RD ST &
LAKE WASHINGTON BLVD N
RENTON , WA 98056
T2B/D - WAKVD02K00 1X2 -
WAKVD02G00 2X4 (RN25A 2X2) - RF
JB0000845743
NODE SEGMENTATION
CANNON COMPANIES
Chuck Schroeder - (253) 922-2787- cschroeder@cannonconstructioninc.com
ROW FOOTAGES*:
NEW BUILDING PATHWAY =
EXISTING BUILDING PATHWAY =
NEW UNDERGROUND =
EXISTING UNDERGROUND =
TOTAL SITE FOOTAGE =
0 FT.
0 FT.
0 FT.
0 FT.
0 FT.
SITE FOOTAGES*:
TOTAL PROJECT FOOTAGE =2319 FT.
POLE INFORMATION:
POLE COUNT =
POLES THAT NEED PERMIT =
POLES THAT NEED MAKE READY =
TRANSMISSION = 0
DISTRIBUTION = 0
2
0
0
48 CT FIBER: 2319 FT + 20% STORAGE = 2783 FT
SCOPE OF WORK:
-TIE INTO SPLICE CASE SP.WAKV.0426 WITH 48CT FIBER.
-PLACE 48CT SHEATH 200' STORAGE @ RISER.
-PULL 48 CT FIBER IN EXISTING CONDUIT, (TYPICAL).
-PLACE 48CT SHEATH 200' STORAGE EVERY 1500'.
-UPGRADE DOG-HOUSE TO TIGER-HOUSE AND PLACE 1X2 RPHY NODE.
-SPLICE INTO EXISTING SPLICE CASE; WAKVD02K01_SP0120.WAKV WITH 48CT FIBER.
-REPLACE / RE-LASH DAMAGED COAX.
-UPGRADE (1) VAULT TO DOGHOUSES.
MFP22003041
GENERAL NOTES
STANDARD
1. THE LOCATIONS OF UTILITIES SHOWN ON THE PLANS ARE APPROXIMATE. ALL UTILITY LOCATIONS SHALL BE VERIFIED PRIOR TO
CONSTRUCTION. THE CONTRACTOR, AT HIS OWN EXPENSE, SHALL MAKE EXCAVATIONS AND BORINGS AHEAD OF THE WORK, AS
NECESSARY, TO DETERMINE THE EXACT LOCATIONS OF UTILITIES AND UNDERGROUND STRUCTURES. IT IS UNDERSTOOD THAT
THERE WILL BE INTERFERING UTILITIES AND OTHER UNDERGROUND PIPES, DRAINS OR STRUCTURES ENCOUNTERED THAT ARE
NOT SHOWN OR AREAS SHOWN INCORRECTLY ON THE PLANS OR THAT HAVE NOT BEEN PREVIOUSLY DISCOVERED IN THE FIELD.
THE CONTRACTOR AGREES THIS IS A NORMAL AND USUAL OCCURRENCE IN THE CONSTRUCTION OF UNDERGROUND
IMPROVEMENTS. FURTHERMORE, CONTRACTORS UNDERSTAND AND AGREE THAT WORK IN SOME CASES PROPOSED PATH MAYBE
IN CLOSE PROXIMITY TO SAID UTILITIES AND UNDERGROUND PIPES, DRAINS AND STRUCTURES NOT SHOWN ON THE PLANS WHICH
MAY REQUIRE A CHANGE IN OPERATIONS AND MAY CAUSE SLOUGHING OF THE TRENCH, ADDITIONAL TRAFFIC CONTROL,
ADDITIONAL PAVEMENT AND BACKFILL COSTS AND TIME. THE CONTRACTOR AGREES THAT A REASONABLE NUMBER OF THESE
OCCURRENCES IS USUAL AND ORDINARY, AND ARE REFLECTED IN THE BID AND PLAN OF OPERATION. THE CONTRACTORS AGREES
TO PROVIDE FOR THESE CONFLICTS AND AGREES TO PROVIDE FOR A REASONABLE AMOUNT OF TIME FOR DESIGN CHANGES
AND/OR UTILITY RELOCATIONS DUE TO SAID CONFLICTS.
2. CALL THE UTILITIES UNDERGROUND LOCATION CENTER AT 811
3. INSPECTIONS - THE CONTRACTOR SHALL NOTIFY LOCAL JURISDICTIONS FOR REQUIRED INSPECTION SERVICES.
4. EXCESS WATER - SHOULD WATER BE ENCOUNTERED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
DEWATER, AS PER LOCAL JURISDICTIONS STANDARD SPECIFICATIONS, BEFORE CONSTRUCTION CONTINUES.
5. NO SILT LADEN WATER IS TO BE DISCHARGED FROM THE SITE WITHOUT PASSING THROUGH AN EROSION CONTROL SYSTEM.
6. THE CONTRACTOR SHALL SCHEDULE AND CONTROL HIS/HER WORK SO AS TO COMPLY WITH ALL APPLICABLE ORDINANCES TO
PREVENT ANY HAZARDS TO PUBLIC SAFETY, HEALTH AND WELFARE.
7. ALL STREETS SHALL BE KEPT FREE OF DIRT AND DEBRIS ON A CONTINUOUS BASIS.
8. AN APPROVED COPY OF THESE PLANS WILL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
9. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITIONS OF THE JOB SITE, INCLUDING SAFETY
OF ALL PERSONS AND PROPERTY DURING THE PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY
AND NOT BE LIMITED TO NORMAL WORKING HOURS.
10. PEDESTRIAN AND VEHICULAR ACCESS TO ADJACENT PROPERTIES SHALL BE MAINTAINED AT ALL TIMES EXCEPT WHERE PRIOR
WRITTEN APPROVAL FROM THE PROPERTY OWNER HAS BEEN OBTAINED.
11. BARRICADE OPEN DEPRESSIONS AND HOLES OCCURRING AS PART OF THIS WORK, AND POST WARNING LIGHTS ON ADJACENT
PROPERTIES WITH PUBLIC ACCESS. OPERATE WARNING LIGHTS DURING HOURS FROM DUSK TO DAWN EACH DAY AND AS
OTHERWISE REQUIRED.
12. PROTECT STRUCTURES, UTILITIES, PAVEMENTS, AND OTHER FACILITIES FROM DAMAGE CAUSED BY SETTLEMENT, LATERAL
MOVEMENT, UNDERMINING WASHOUT AND OTHER HAZARDS CREATED BY OPERATIONS UNDER THIS SECTION.
TRAFFIC CONTROL
1. THE CONTRACTOR IS ADVISED THAT ALL LANE CLOSURES SHALL BE KEPT TO A MINIMUM. LOCAL JURISDICTIONS WILL APPROVE
ONLY THOSE LANE AND ROADWAY CLOSURES DETERMINED TO BE NECESSARY FOR THE CONTRACTOR TO ACCOMPLISH A
SPECIFIC TASK. NO LANE OR ROADWAY CLOSURES WILL BE PERMITTED WITHOUT PRIOR APPROVALS.
2. THE CONTRACTOR SHALL KEEP ALL TRAFFIC LANES AND SHOULDERS CLEAR OF EQUIPMENT AND MATERIALS DURING
NON-WORKING HOURS. EQUIPMENT AND MATERIALS SHALL NOT BE STORED ON THE STREETS. THE CONTRACTOR'S EMPLOYEES
AND AGENTS SHALL NOT PARK PRIVATE VEHICLES ALONG THE ROADWAY OR MEDIAN.
SITE PREPARATION
1. SOD AND LAWN TO BE REMOVED SHALL BE CUT TO A NEAT VERTICAL LINE 6" MINIMUM BEYOND THE TRENCH LINE. SOD SHALL BE
EITHER REMOVED FROM THE SITE, OR CAREFULLY STOCKPILED FOR REUSE.
2. SAW CUT PAVEMENT TO A NEAT VERTICAL LINE 8" TO 12" MINIMUM BEYOND THE TRENCH LINE. REPLACE PAVEMENT WITH LIKE
MATERIAL (I.E., ASPHALT WITH ASPHALT, CONCRETE WITH CONCRETE).
3. EXCEPT AS NOTED HEREIN, ALL MATERIAL REMOVED SHALL BE TAKEN FROM THE SITE AND DISPOSED OF BY THE CONTRACTOR.
TRENCH EXCAVATION AND BACKFILL
1. TRENCH BACKFILL - WHERE MATERIAL EXCAVATED FROM TRENCHES IS UNSUITABLE FOR BACKFILL, THE CONTRACTOR SHALL
BACKFILL WITH BANK RUN GRAVEL OR MAY ELECT TO USE CDF IN LIEU OF THE COMPACTION/PROCTOR PROCESS. STONEWAY MIX
351 IS ACCEPTABLE IN ALL LOCATIONS. QUICK SETTING MIX 1004 IS ACCEPTABLE IN NON-TRAFFIC AREAS. MIX 1121 IS TO BE USED IN
TRAFFIC-BEARING LOCATIONS.
2. COMPACTION, WHEN NECESSARY, SHALL BE PERFORMED IN ACCORDANCE WITH LOCAL JURISDICTION REQUIREMENTS.
UTILITY DUCT
1. BURIED DUCT SHALL BE (1) 4" SCHEDULE 40 PVC, UNLESS NOTED OTHERWISE. MINIMUM CONDUIT COVER SHALL BE 36" WITH A
MINIMUM SLOPE OF 1/2 % TO VAULT.
2. THOROUGHLY CLEAN CONDUIT BEFORE USING OR LAYING. DURING CONSTRUCTION AND AFTER THE DUCT LINE IS COMPLETED,
PLUG ENDS OF CONDUITS TO PREVENT WATER WASHING INTO CONDUIT OR MANHOLES, TAKE PARTICULAR CARE TO KEEP
CONDUITS CLEAR OF CONCRETE, DIRT AND ANY OTHER SUBSTANCE DURING THE COURSE OF CONSTRUCTION.
3. AFTER DUCT PLACEMENT HAS BEEN COMPLETED, PROOF AND CLEAN DEBRIS FROM EACH DUCT, ITS ENTIRE LENGTH. INSTALL PULL
ROPE AND PLACE WATERTIGHT COMPRESSION PLUGS AT BOTH ENDS. ANY CONDUITS CONTAINING FIBER CABLE WILL REQUIRE
SIMPLEX COMPRESSION PLUGS SEALING THE CONDUITS AROUND THE CABLE.
4. OUTSIDE INNERDUCT SHALL BE 1-1/4" OPTIC-GUARD NON-METALLIC FLEXIBLE, IN COLOR SUCH AS RED OR ORANGE, WITH PULL
ROPES AND PLUGS. EXPOSED INNERDUCT INSIDE OF BUILDINGS SHALL BE PLENUM-RATED.
CEMENT CONCRETE PAVEMENT
1. ALL CONCRETE PAVEMENT REMOVED OR DAMAGED BY THIS WORK SHALL BE REPLACED ACCORDING TO THE STANDARD
SPECIFICATIONS OF EACH JURISDICTION.
ASPHALT CONCRETE PAVEMENT
1. ALL ASPHALT CONCRETE PAVEMENT REMOVED OR DAMAGED BY THIS WORK SHALL BE REPLACED WITH CLASS B ASPHALT
CONCRETE ACCORDING TO THE REQUIREMENTS OF EACH JURISDICTION.
GRAVEL AREAS
1. ALL GRAVEL AREAS DAMAGED OR REMOVED BY THIS WORK SHALL BE REPLACED WITH CRUSHED SURFACING TOP COURSE IN
ACCORDANCE WITH THE REQUIREMENTS OF EACH JURISDICTION.
SITE RESTORATION
1. ALL DISTURBED OR DAMAGED AREAS SHALL BE RESTORED TO A CONDITION EQUAL TO, OR BETTER THAN, THAT WHICH EXISTED
PRIOR TO PLACEMENT OF THE CONDUIT AND STRUCTURES.
2. VEGETATION REMOVED FOR THIS WORK SHALL BE REPLACED WITH IN-KIND PLANT MATERIAL AND SHALL BE PROPERLY PLANTED
AND WATERED IN TO ENSURE ITS SURVIVAL.
3. SITE RESTORATION SHALL INCLUDE REPLACING EXISTING CABLING AND PULL ROPES IN EXISTING CONDUITS AS THEY EXISTED
PRIOR TO CONSTRUCTION.
WATER QUALITY
1. CONSTRUCTION ACTIVITIES OCCURRING ADJACENT TO STORM DRAINAGE STRUCTURES SHALL COMPLY WITH THE STATE OF
WASHINGTON'S WATER QUALITY STANDARDS
2. THE CONTRACTOR SHALL LIMIT THE USE OF PETROLEUM PRODUCTS ON THE SITE.
DIRECTIONAL BORING
1. WHEN BORING ROADWAYS, INSTALL (1) 4" SCHEDULE 40 PVC CONDUIT WITH PULL ROPES AND PLUGS.
2. PROTECT EXISTING UTILITIES -- COORDINATE WITH LOCAL JURISDICTIONS TO POTHOLE AS REQUIRED TO LOCATE EXISTING
UTILITIES.
FIRE PROTECTION
1. ALL INSTALLED BACKBOARDS SHALL BE PAINTED WITH FIRE-RESISTANT PAINT.
2. ALL FIRE SEALED DUCT ENDS AND CORES SHALL BE 2 HOUR FIRE-RATED. ALL FIRE SEAL IN EXISTING LOCATIONS SHALL BE
REPAIRED OR REPLACED UPON DUCT OR CABLE PLACEMENT.
AERIAL INSTALLATION
1. ALL AERIAL CONSTRUCTION IS TO BE PERFORMED TO INDUSTRY ACCEPTABLE STANDARDS.
2. ALL NEW AERIAL (AND EXISTING) CABLE HEIGHTS OF ATTACHMENT TO BE DOCUMENTED AT TIME OF CONSTRUCTION.
3. 6.35 MM STRAND TO BE USED WITH STANDARD 1/4" POLE LINE HARDWARE UNLESS OTHERWISE SPECIFIED. BOND STRAND TO
POWER MAIN WHERE APPLICABLE.
4. ALL ANCHORS TO BE USED WILL BE 3/4" SCREW TYPE.
5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN AND FOLLOW ALL NESC CODES ALONG
WITH APPLICABLE LOCAL AND REGIONAL GOVERNING AUTHORITIES. ANY DISCREPANCIES BETWEEN
THESE AUTHORITIES AND OR THE CONSTRUCTION PERMITS IS TO BE VALIDATED WITH THE
DESIGNER OR ENGINEER PRIOR TO CONSTRUCTION.
OF
APPROVED BY:
PROJECT CODE:
DRAWN BY:
DATE:
SCALE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0000845743WAKVD02K00 1X2-WAKVD02G00 2X4 (R25A 2X2)N 43RD ST & LAKE WASHINGTON BLVD NRENTON, WA 98056NODE SEGMENTATION17-050
2/9/2022
JBL
CS
NTS
0 0 0
2
416/3/2022SPLIT PERMIT INTO MUTIPLE PARTSJBLGENERAL NOTES
MFP22003041
OF
APPROVED BY:
PROJECT CODE:
DRAWN BY:
DATE:
SCALE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0000845743WAKVD02K00 1X2-WAKVD02G00 2X4 (R25A 2X2)N 43RD ST & LAKE WASHINGTON BLVD NRENTON, WA 98056NODE SEGMENTATION17-050
2/9/2022
JBL
CS
NTS
0 0 0
3
416/3/2022SPLIT PERMIT INTO MUTIPLE PARTSJBLLEGEND
EDGE OF PAVEMENT
FOGLINE
POWER
COMMUNICATION
SEWER
DRAIN
DRAINAGE DITCH
GAS
WATER
TRAFFIC SIGNAL
TELCOM
STEAM
UNKNOWN UTILITY
RIGHT OF WAY
TRAFFIC CONES
PROPOSED NEW BORE
STRAW WATTLES
P
LT
CW
R
UTILITY POLE
VAULT - SMALL
PEDESTAL
STREET LIGHT
CROSSWALK LIGHT
UTILITY RISER
V VAULT - SMALL
444LA MANHOLE
VAULT - 25TA
CATCH BASIN
CATCH BASIN WITH SOCK
GLULAM UTILITY POLECENTER LINE
LANE LINE
FENCE
HIGH VISIBILITY FENCE
S SEWER MANHOLE
D DRAIN MANHOLE
W WATER MANHOLE
V UTILITY VALVE
SHRUBBERY
BORE PIT
VAULT - LARGE
VAULT - 25TA
C COMMUNICATION MANHOLE
FIRE HYDRANT
DISTANCE STATIONSTA 0+00
CONSTRUCTION NOTE CALLOUT#
X.X DISTANCE DIMENSION
ASPHALT SURFACE
CONCRETE ROADWAY PANEL
HF H-FRAME
VAULT - LARGE
CAB CABINET
LEGEND
LANE DIRECTION INDICATOR
PROPOSED
MARK-UP NOTATIONS RESTORATION TYPESEXISTING FEATURESLINE TYPES
A
7
LANDSCAPE
CROSS SECTION SYMBOL
CROSS SECTION NAME
CROSS SECTION SHOWN ON PAGE
FL FL
P P
TS TS
C C
D D
DD DD DD DD DD
G G
W W
T T
ST ST
ROW ROW
S
UK
CB
CB
P P
V V V
V VV
WORK BEING DONE1LOCATION PHOTO NOTE CALLOUT
#PHOTO LOCATOR SYMBOL
PROPOSED NEW TRENCH
EXISTING UNDERGROUND PATHWAY
PROPOSED NEW AERIAL STRAND
EXISTING AERIAL PATHWAY
EXISTING SPLICE CASE
PROPOSED SPLICE CASE
EXISTING FIBER/COAX STORAGE
PROPOSED FIBER/COAX STORAGE
TREE
EOP
V VAULT - SMALL
444LA MANHOLE
VAULT - 25TA
VAULT - LARGE
EXISTING - CONTINUED
233LA MANHOLE
233LA MANHOLE
MFP22003041
4350
4101
4107
4113
4119
4125
4151
4157
4163
4169
4175
4205
4211
4217
4223
4229
4235
4255
4261
4267
1000
1006 1012 1018
1024 1030
1036 1102 1108 1114 1120 1126 1210 1216 1222 1228 1234 1240
1246 1252
1007 1013 1019 1025 1031 1037 1103 1109 1115 1121
1211 1217 1223 1229 1235 1241
1002
1008
1014
1020
1026
1032
1038
1104
12041132
1110
1116
1122
1128
1003
1009
1015
1021
1027
1033
1039
1111
1117
1123
1129
1219
4122
4118
4112
4106
1225 1231
4109
4115
4121
4127
1213
1207
1201
0
0
0
0
0
0
1105 LAKE WASHINGTON BLVD NN 42ND PLN 42ND PL
WILLIAMS AVE NN 41ST
P
L
WILLIAMS AVE N
EOPEOPEOPEOPEOP
EOPEOPEOP
EOP
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP
EOPEOPEOP
EOP
EOPEOPEOPEOP
EOPEOPEOPEOP
EO
P
EO
P
EOP
EOPEOPEOPEOPEOPEOPEOP
EOP
EOP
EOP
EOP EOP EOP EOP EOP EOPEOP
EOPEOPEOPEOP EOP
EOP
EOP
EOP
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOP
EOPEOPEOPEOPEOP
EOP
EOP EOPEOPEOPEOP
EOP
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEO
P
EOP
EOP
EOP EOPEOPEOPEOP
EOP
EOP
EOP
EOP
EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP
EOP
EOP
EOP
EOP
EOP
EOP EOP EOP
EOP
EOP
EOP EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPASPHALTASPHALTASPHALTASPHALTSIDEWALK SIDEWALK SIDEWALK SIDEWALK
SIDE
WALK
SIDE
W
ALK
SIDE
W
ALK
SIDEWALK
SIDEW
A
L
K
SIDE
W
A
LK
SIDEWALK
SIDE
W
A
LK
SIDE
W
ALK
SIDEWALK
SIDEWALK
SIDEWALK
SIDEWALK
SIDEW
ALK
SIDEWALK
SIDE
W
ALK
SIDEWALK
SIDE
W
ALK
SID
E
W
A
L
K
SIDEWALKSIDEW
A
L
K SIDEWALK
LANDSCA
P
E
SIDEW
A
L
K
SIDEW
A
L
KSIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALK
SIDEWALK
SIDEWALKSIDEWA
LK SIDEWALKSIDEWA
LKSIDEWA
LK
SIDEWA
L
K
SIDEWA
L
K
SIDEWA
L
K
SIDEWALK
SIDEWALK SIDEWAL
KSIDEWALK SIDEWALKSIDEWALKSIDEWALKSIDEWALK
SIDE
W
A
L
K
SIDEWALKSIDEWALKSIDEWALK
SIDEWALK SIDEWALK SIDEWALK SIDEWALK
SIDEWALK SIDEWALK
SIDEWA
L
K
SIDE
W
A
L
K
SID
E
W
A
L
K
SIDE
WA
LK
LANDSCAPE
LANDSCAPELANDSCAPE
LANDSCAPELANDSCAP
E
LANDSCAP
E
LANDSCA
P
E
LANDSCAPE LANDSCAPELANDSCAPE
LANDSCAPE
LAND
S
C
A
P
E
LANDSCAPE LANDSCAPE
LANDSCAPE LANDSCAPE
LANDSCAPE LANDSCAPE
LANDSCAPE
LANDSCAPE
LANDSCAPE
LANDSCAPE
LAND
S
C
A
P
E
LANDSCAPE
GRASS
GRASS
GRASS
GRASS
LANDSCAPE LANDSCAPELANDSCAPELANDSCA
P
E
LAND
S
C
A
P
E
LAND
S
C
A
P
E
LAND
S
C
A
P
E
LANDSCAPE
LANDSCAPELANDSCAPE
LANDSCAPE
LANDSCAPE
LANDSCAPE
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVE
W
A
Y
DRIVEW
A
Y
DRIVE
W
A
Y
DRIVE
W
A
Y
DRIVEW
A
Y
DRIVEW
A
Y
DRIVEWAY
DRIVEWAY
DRIVEWA
Y
DRIVEWAY
DRIVEW
A
Y
DRIVEW
A
Y
DRIVEWAY
DRIVE
W
A
Y
DRIVEWAY
DRIVE
W
A
Y
DRIVEWA
Y
DRIVEWA
Y
DRIVEWA
Y
DRIVEWA
Y
DRIVEWA
Y
DRIVEW
A
Y DRIVEWAY
DRIVE
W
A
Y
DRIVEWA
Y
DRIVEWA
Y DRIVEWAY DRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAY
EOP EOP EOP EOP
EOPEOPEOPEOPASPHALTASPHALT
ASPHALT
ASPHALT
ASPH
A
L
T
ASPH
A
L
T
ASPHAL
T
ASPHA
L
T
ASPHALT
ASPHALT ASPHALTASPHALT
ASPHALT
ASPHALT
ASPH
ALTASPHALT
ASP
H
A
L
T
ASPH
A
L
T
ASP
H
A
L
T
ASPH
A
L
T
ASP
H
A
L
T
ASPH
A
L
T
ASPHALTASPHALT
ASPHAL
T
ASPHALT
ASPHA
LT
ASPH
A
LT
ASPHAL
T
ASPHALT
ASPHALTASPHAL
T
ASP
H
A
L
T
ASP
H
A
L
T
ASP
H
A
L
T
ASP
H
A
L
T
ASPHA
LTASPHALT
ASPHAL
T
ASPHA
L
T
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHAL
T
ASP
H
A
L
T
ASPHALTASPHALTASPHALTASPHALTSIDE
WALK
R
25'
PLACE 1X2 RPHY
NODE HERE
SPLICE INTO EXISTING
SPLICE CASE;
WAKVD02K01_SP0120.WAKV
UPGRADE TO TIGER HOUSE
FOR NODE PLACEMENT
TIE INTO SPLICE
CASE SP.WAKV.0426
PLACE 48CT SHEATH 200'
STORAGE EVERY 1500'
PULL 48 CT FIBER IN
EXISTING CONDUIT,
(TYPICAL)
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROWROWROW
ROW ROW
ROW
ROW ROW
ROW
ROW ROW
ROW ROW
ROW
ROW ROW
ROW
ROW ROW
ROW
ROW
ROW
ROW ROW
ROW
ROW ROW
ROW
ROW
ROW
ROW ROW
ROW
ROW ROW
ROW
ROW ROW
ROW ROW
ROW
ROW ROW
ROW
ROW ROW
ROW
ROW
ROW
ROW ROW
ROW
ROW ROW
ROWROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROWROWROWROWROWROW ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW ROWROWROWROWROWROW
ROW ROW ROW ROW ROW ROW
ROW
ROW
ROW
ROW ROW
ROW
ROW
ROW
ROW ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW
ROWROWROWROWROWROWROWROWROW
ROWROWROWROWROWROW
ROWROWROWROWROWROWROWROWROWROWROWV
V
V
55'200'
PLACE 48CT SHEATH
200' STORAGE @ RISER75'200'100'
100'
140'
2
0
0
'100'203'
85'
100'
156'
120'110'350'25'
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DH
P
P
P
P
P
P
P
P P
P
P
P
SIDEWA
L
K
P
P
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FLFL
FL
FL
FL
FL
FLFL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL FLFL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FLFL
FL
FL
FL
FL
FL
FL
FL FL FL FLFL
FL
FL
FL
FL
FL
FL
FL FL FL FL FL FL FL
FL
FL FL FL
FL
FL
FL FL FL
FL
FL
FL
FL FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL FL FL FL FL FL FL FL FL
FL
FL
FL
FL
FL
FL
FL FL
FL
FL
FL FL FL
FL
FL
FL
FL FL FLFL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FLEOP
DRIVEWAY
DRIVEWAY
OF
APPROVED BY:
PROJECT CODE:
DRAWN BY:
DATE:
SCALE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0000845743WAKVD02K00 1X2-WAKVD02G00 2X4 (R25A 2X2)N 43RD ST & LAKE WASHINGTON BLVD NRENTON, WA 98056NODE SEGMENTATION17-050
2/9/2022
JBL
CS
1:80
0'40'80'
4
416/3/2022SPLIT PERMIT INTO MUTIPLE PARTSJBLDESIGN
N
MFP22003041
Cannon Construction LLC.
406 Porter Way
Milton, WA 98354
6/29/2022
City of Renton
1055 South Grady Way
Renton, WA 98057
RE: Aerial Variance Request for JB0000845743
To whom it may concern:
Cannon Construction has been contracted to design and engineer this project on behalf of
Comcast Cable Communications Management. Comcast is applying for a variance request in
order to upgrade their existing facilities.
Comcast proposes to TIE INTO SPLICE CASE SP.WAKV.0426 WITH 48CT FIBER. PLACE 48CT SHEATH 200'
STORAGE @ RISER. PULL 48 CT FIBER IN EXISTING CONDUIT, (TYPICAL). PLACE 48CT SHEATH 200'
STORAGE EVERY 1500'. UPGRADE DOG-HOUSE TO TIGER-HOUSE AND PLACE 1X2 RPHY NODE. -SPLICE
INTO EXISTING SPLICE CASE; WAKVD02K01_SP0120.WAKV WITH 48CT FIBER. REPLACE / RE-LASH
DAMAGED COAX. UPGRADE (1) VAULTS TO DOGHOUSES. 1252 N 42nd Pl. RENTON, WA 98056.
Comcast is requesting that the City of Renton approve this variance request based on the fact
that the requirements for undergrounding this proposed over-lash on existing plant will cause
undue hardship.
1. Installation of undergrounding facilities will increase the total cost of construction
roughly 15-25 times the amount of an aerial over-lash on the existing Comcast strand.
2. Risk of potential damage to underground facilities will be increased.
3. Over-lash will not cause substantial adverse impact to other persons or entities in the
immediate area. Over-lashing the cable will be accomplished in a few days, and the
residents will not notice any impact. Comcast will clean up the over-lashed spans as
necessary and identify and remove any existing dead cables along this route.
4. The variance is necessary to prevent any undue hardship due to the increased
construction costs if forced to install the proposed extension underground.
5. The granting of the variance will not be materially detrimental to the public welfare.
Comcast does agree to participate in future underground improvements for its
proportionate share of the undergrounding costs, waiving the obligation into the future
when all other utilities are undergrounded to prevent an undue hardship against
Comcast currently.
Upon the granting of the variance, Comcast will coordinate construction and traffic control as
per your requirements. Comcast and their contractors want to cooperate at the highest level
and agree to adhere to all provisions and requirements set forth by the City of Renton to insure
safe installation and maintenance of the proposed facilities.
If you have any further questions regarding this project, please contact Chuck Schroeder
253.268.8701
Thank you for your consideration in this matter.
David Standring
Permit Coordinator
Cannon Construction Inc.
o 253-922-2787 I permitting@teamcannon.com
July 5, 2022
David Standring
Cannon Construction Inc.
4610 Tacoma Avenue,
Sumner WA 98390
Via Email: Permitting@teamcannon.com
SUBJECT: Request for Undergrounding Exemption (JB#845743, MFP22003041, 1252 N 42nd Pl)
Dear Mr. Standring:
The City of Renton has reviewed your request to grant Comcast an exemption from Renton Municipal
Code (RMC) 4-6-090(C) which states that all new electrical or communication facilities shall be required
to be installed underground, pursuant to the standards of the section of RMC.
Comcast proposes to have Cannon Construction Inc overlash new coax and fiber for a total of
approximately 350 lineal feet to existing Puget Sound Energy (PSE) poles along Lake Washington Blvd N
within the City. See the enclosed Site Plan showing the proposed overlashing limits.
ANALYSIS: The City has considered the request for an exemption from RMC 4-6-090. Ordinance 5720
grants Comcast, the right to install fiber optic cable and related appurtenances under, along, over, below,
through and across the streets, avenues and alleys of City of Renton within the right-of-way of Renton.
Section 3.4 of the franchise ordinance states that if all of the distribution lines all the wireline service
providers, such as telecommunications service providers, as defined in RCW 35.99.010, a utility service
provider or a Cable Operator (collectively “Service Providers”) in any portion of the Franchise Area are
underground, Grantee shall place its Cable System’s distribution cables underground within that area;
provided that such underground locations are actually capable of accommodating Grantee’s cable and
other equipment without technical degradation of the Cable Systems’ signal quality.
The proposal would utilize existing poles with other attached franchisee communication facilities and
overlash to the existing Comcast aerial path. As minimum vertical height clearance of 15’-6” would need
to be provided for, any existing obsolete cable will need to be removed; staff recommends these as
conditions of approval. Therefore, the City is granting an exemption with conditions, per the Comcast
franchise agreement which allows new overhead facilities to be placed overhead provided there are other
similar providers overhead as well. Comcast is required to obtain all necessary private utility easements
for work on private property.
DECISION: The requested exemption from underground utility installation requirements RMC4-6-090 (C)
as requested by the applicant is approved with conditions subject to the conditions below as the request
complies with the Comcast Franchise Agreement.
Comcast Job JB#845743
Page 2 of 2
July 5, 2022
Conditions of Approval:
1. Any existing height violations within the Project Reach must be resolved at the time of
construction. New aerial lines within the Project Reach must have a minimum vertical clearance
of 15’-6”.
2. Any abandoned or unused lines within the Project Reach must be removed at the time that
construction is taking place.
3. A traffic control plan must be separately submitted to the City, and no construction may take
place until the City has approved a traffic control plan.
4. The new aerial fiber lines within the Project Reach must be converted to underground facilities in
the future, at the Applicant’s cost, when any one of the following events occurs: (1) any other
utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a
franchisee within the Project Reach, in which case the Applicant shall participate in the joint use
trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made
available within the Project Reach that will accommodate the aerial lines. The new aerial lines
must be undergrounded within one year, or approved otherwise by the City of Renton Community
and Economic Development Administrator or designee, from the first event triggering the
requirement to underground the aerial lines.
This decision to approve the exemption with conditions is subject to a fourteen (14) day appeal period
from the date of this letter per RMC 4-8-110. Any appeals of the administrative decision must be filed
with the City Clerk, along with the required appeal fee, by 5:00 pm, July 19, 2022. Due to the ongoing
state of emergency enacted by Governor’s Proclamation 20-28.14 (and as amended), the City Clerk’s
Office is working remotely. For that reason, appeals must be submitted electronically to the City Clerk at
cityclerk@rentonwa.gov or delivered to City Hall 1st floor Lobby Hub Monday through Friday. The appeal
fee, normally due at the time an appeal is submitted, will be collected at a future date if your appeal is
submitted electronically. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional
information regarding the appeal process may be obtained from the City Clerk’s Office,
cityclerk@rentonwa.gov.
Sincerely,
Brianne Bannwarth, PE
Development Engineering Director
cc: C.E. “Chip” Vincent, CED Administrator
Vanessa Dolbee, Planning Director
Justin Johnson, Construction Engineering Manager
Scott Warlick, Engineering Specialist III
Holly Powers, Engineering Specialist III
Franchise Permits
Enclosures: Site Plan
SHEET INDEX:
1 - COVER SHEET
2 -GENERAL NOTES
3 -LEGEND
4 -DESIGN
THIS IS PROPRIETARY INFORMATION AND NOT MEANT FOR GENERAL PUBLICATION. ALL RIGHTS RESERVED BY CANNON COMPANIES
CONTACTS:
PROJECT MAP:
*ALL FOOTAGES AND MATERIALS ARE ESTIMATED
N
BILL OF MATERIALS*:
RE-LASH =
OVER-LASH =
NEW UNDERGROUND =
EXISTING UNDERGROUND =
RISER (1)=
TOTAL ROW FOOTAGE =
0 FT.
350 FT.
0 FT.
1944 FT.
25 FT.
2319 FT.
CANNON COMPANIES
SAFETY | QUALITY | INTEGRITY | TEAMWORK
Connecting The Future Since 1985
COMCAST
N 43RD ST &
LAKE WASHINGTON BLVD N
RENTON , WA 98056
T2B/D - WAKVD02K00 1X2 -
WAKVD02G00 2X4 (RN25A 2X2) - RF
JB0000845743
NODE SEGMENTATION
CANNON COMPANIES
Chuck Schroeder - (253) 922-2787- cschroeder@cannonconstructioninc.com
ROW FOOTAGES*:
NEW BUILDING PATHWAY =
EXISTING BUILDING PATHWAY =
NEW UNDERGROUND =
EXISTING UNDERGROUND =
TOTAL SITE FOOTAGE =
0 FT.
0 FT.
0 FT.
0 FT.
0 FT.
SITE FOOTAGES*:
TOTAL PROJECT FOOTAGE =2319 FT.
POLE INFORMATION:
POLE COUNT =
POLES THAT NEED PERMIT =
POLES THAT NEED MAKE READY =
TRANSMISSION = 0
DISTRIBUTION = 0
2
0
0
48 CT FIBER: 2319 FT + 20% STORAGE = 2783 FT
SCOPE OF WORK:
-TIE INTO SPLICE CASE SP.WAKV.0426 WITH 48CT FIBER.
-PLACE 48CT SHEATH 200' STORAGE @ RISER.
-PULL 48 CT FIBER IN EXISTING CONDUIT, (TYPICAL).
-PLACE 48CT SHEATH 200' STORAGE EVERY 1500'.
-UPGRADE DOG-HOUSE TO TIGER-HOUSE AND PLACE 1X2 RPHY NODE.
-SPLICE INTO EXISTING SPLICE CASE; WAKVD02K01_SP0120.WAKV WITH 48CT FIBER.
-REPLACE / RE-LASH DAMAGED COAX.
-UPGRADE (1) VAULT TO DOGHOUSES.
MFP22003041
GENERAL NOTES
STANDARD
1. THE LOCATIONS OF UTILITIES SHOWN ON THE PLANS ARE APPROXIMATE. ALL UTILITY LOCATIONS SHALL BE VERIFIED PRIOR TO
CONSTRUCTION. THE CONTRACTOR, AT HIS OWN EXPENSE, SHALL MAKE EXCAVATIONS AND BORINGS AHEAD OF THE WORK, AS
NECESSARY, TO DETERMINE THE EXACT LOCATIONS OF UTILITIES AND UNDERGROUND STRUCTURES. IT IS UNDERSTOOD THAT
THERE WILL BE INTERFERING UTILITIES AND OTHER UNDERGROUND PIPES, DRAINS OR STRUCTURES ENCOUNTERED THAT ARE
NOT SHOWN OR AREAS SHOWN INCORRECTLY ON THE PLANS OR THAT HAVE NOT BEEN PREVIOUSLY DISCOVERED IN THE FIELD.
THE CONTRACTOR AGREES THIS IS A NORMAL AND USUAL OCCURRENCE IN THE CONSTRUCTION OF UNDERGROUND
IMPROVEMENTS. FURTHERMORE, CONTRACTORS UNDERSTAND AND AGREE THAT WORK IN SOME CASES PROPOSED PATH MAYBE
IN CLOSE PROXIMITY TO SAID UTILITIES AND UNDERGROUND PIPES, DRAINS AND STRUCTURES NOT SHOWN ON THE PLANS WHICH
MAY REQUIRE A CHANGE IN OPERATIONS AND MAY CAUSE SLOUGHING OF THE TRENCH, ADDITIONAL TRAFFIC CONTROL,
ADDITIONAL PAVEMENT AND BACKFILL COSTS AND TIME. THE CONTRACTOR AGREES THAT A REASONABLE NUMBER OF THESE
OCCURRENCES IS USUAL AND ORDINARY, AND ARE REFLECTED IN THE BID AND PLAN OF OPERATION. THE CONTRACTORS AGREES
TO PROVIDE FOR THESE CONFLICTS AND AGREES TO PROVIDE FOR A REASONABLE AMOUNT OF TIME FOR DESIGN CHANGES
AND/OR UTILITY RELOCATIONS DUE TO SAID CONFLICTS.
2. CALL THE UTILITIES UNDERGROUND LOCATION CENTER AT 811
3. INSPECTIONS - THE CONTRACTOR SHALL NOTIFY LOCAL JURISDICTIONS FOR REQUIRED INSPECTION SERVICES.
4. EXCESS WATER - SHOULD WATER BE ENCOUNTERED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
DEWATER, AS PER LOCAL JURISDICTIONS STANDARD SPECIFICATIONS, BEFORE CONSTRUCTION CONTINUES.
5. NO SILT LADEN WATER IS TO BE DISCHARGED FROM THE SITE WITHOUT PASSING THROUGH AN EROSION CONTROL SYSTEM.
6. THE CONTRACTOR SHALL SCHEDULE AND CONTROL HIS/HER WORK SO AS TO COMPLY WITH ALL APPLICABLE ORDINANCES TO
PREVENT ANY HAZARDS TO PUBLIC SAFETY, HEALTH AND WELFARE.
7. ALL STREETS SHALL BE KEPT FREE OF DIRT AND DEBRIS ON A CONTINUOUS BASIS.
8. AN APPROVED COPY OF THESE PLANS WILL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
9. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITIONS OF THE JOB SITE, INCLUDING SAFETY
OF ALL PERSONS AND PROPERTY DURING THE PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY
AND NOT BE LIMITED TO NORMAL WORKING HOURS.
10. PEDESTRIAN AND VEHICULAR ACCESS TO ADJACENT PROPERTIES SHALL BE MAINTAINED AT ALL TIMES EXCEPT WHERE PRIOR
WRITTEN APPROVAL FROM THE PROPERTY OWNER HAS BEEN OBTAINED.
11. BARRICADE OPEN DEPRESSIONS AND HOLES OCCURRING AS PART OF THIS WORK, AND POST WARNING LIGHTS ON ADJACENT
PROPERTIES WITH PUBLIC ACCESS. OPERATE WARNING LIGHTS DURING HOURS FROM DUSK TO DAWN EACH DAY AND AS
OTHERWISE REQUIRED.
12. PROTECT STRUCTURES, UTILITIES, PAVEMENTS, AND OTHER FACILITIES FROM DAMAGE CAUSED BY SETTLEMENT, LATERAL
MOVEMENT, UNDERMINING WASHOUT AND OTHER HAZARDS CREATED BY OPERATIONS UNDER THIS SECTION.
TRAFFIC CONTROL
1. THE CONTRACTOR IS ADVISED THAT ALL LANE CLOSURES SHALL BE KEPT TO A MINIMUM. LOCAL JURISDICTIONS WILL APPROVE
ONLY THOSE LANE AND ROADWAY CLOSURES DETERMINED TO BE NECESSARY FOR THE CONTRACTOR TO ACCOMPLISH A
SPECIFIC TASK. NO LANE OR ROADWAY CLOSURES WILL BE PERMITTED WITHOUT PRIOR APPROVALS.
2. THE CONTRACTOR SHALL KEEP ALL TRAFFIC LANES AND SHOULDERS CLEAR OF EQUIPMENT AND MATERIALS DURING
NON-WORKING HOURS. EQUIPMENT AND MATERIALS SHALL NOT BE STORED ON THE STREETS. THE CONTRACTOR'S EMPLOYEES
AND AGENTS SHALL NOT PARK PRIVATE VEHICLES ALONG THE ROADWAY OR MEDIAN.
SITE PREPARATION
1. SOD AND LAWN TO BE REMOVED SHALL BE CUT TO A NEAT VERTICAL LINE 6" MINIMUM BEYOND THE TRENCH LINE. SOD SHALL BE
EITHER REMOVED FROM THE SITE, OR CAREFULLY STOCKPILED FOR REUSE.
2. SAW CUT PAVEMENT TO A NEAT VERTICAL LINE 8" TO 12" MINIMUM BEYOND THE TRENCH LINE. REPLACE PAVEMENT WITH LIKE
MATERIAL (I.E., ASPHALT WITH ASPHALT, CONCRETE WITH CONCRETE).
3. EXCEPT AS NOTED HEREIN, ALL MATERIAL REMOVED SHALL BE TAKEN FROM THE SITE AND DISPOSED OF BY THE CONTRACTOR.
TRENCH EXCAVATION AND BACKFILL
1. TRENCH BACKFILL - WHERE MATERIAL EXCAVATED FROM TRENCHES IS UNSUITABLE FOR BACKFILL, THE CONTRACTOR SHALL
BACKFILL WITH BANK RUN GRAVEL OR MAY ELECT TO USE CDF IN LIEU OF THE COMPACTION/PROCTOR PROCESS. STONEWAY MIX
351 IS ACCEPTABLE IN ALL LOCATIONS. QUICK SETTING MIX 1004 IS ACCEPTABLE IN NON-TRAFFIC AREAS. MIX 1121 IS TO BE USED IN
TRAFFIC-BEARING LOCATIONS.
2. COMPACTION, WHEN NECESSARY, SHALL BE PERFORMED IN ACCORDANCE WITH LOCAL JURISDICTION REQUIREMENTS.
UTILITY DUCT
1. BURIED DUCT SHALL BE (1) 4" SCHEDULE 40 PVC, UNLESS NOTED OTHERWISE. MINIMUM CONDUIT COVER SHALL BE 36" WITH A
MINIMUM SLOPE OF 1/2 % TO VAULT.
2. THOROUGHLY CLEAN CONDUIT BEFORE USING OR LAYING. DURING CONSTRUCTION AND AFTER THE DUCT LINE IS COMPLETED,
PLUG ENDS OF CONDUITS TO PREVENT WATER WASHING INTO CONDUIT OR MANHOLES, TAKE PARTICULAR CARE TO KEEP
CONDUITS CLEAR OF CONCRETE, DIRT AND ANY OTHER SUBSTANCE DURING THE COURSE OF CONSTRUCTION.
3. AFTER DUCT PLACEMENT HAS BEEN COMPLETED, PROOF AND CLEAN DEBRIS FROM EACH DUCT, ITS ENTIRE LENGTH. INSTALL PULL
ROPE AND PLACE WATERTIGHT COMPRESSION PLUGS AT BOTH ENDS. ANY CONDUITS CONTAINING FIBER CABLE WILL REQUIRE
SIMPLEX COMPRESSION PLUGS SEALING THE CONDUITS AROUND THE CABLE.
4. OUTSIDE INNERDUCT SHALL BE 1-1/4" OPTIC-GUARD NON-METALLIC FLEXIBLE, IN COLOR SUCH AS RED OR ORANGE, WITH PULL
ROPES AND PLUGS. EXPOSED INNERDUCT INSIDE OF BUILDINGS SHALL BE PLENUM-RATED.
CEMENT CONCRETE PAVEMENT
1. ALL CONCRETE PAVEMENT REMOVED OR DAMAGED BY THIS WORK SHALL BE REPLACED ACCORDING TO THE STANDARD
SPECIFICATIONS OF EACH JURISDICTION.
ASPHALT CONCRETE PAVEMENT
1. ALL ASPHALT CONCRETE PAVEMENT REMOVED OR DAMAGED BY THIS WORK SHALL BE REPLACED WITH CLASS B ASPHALT
CONCRETE ACCORDING TO THE REQUIREMENTS OF EACH JURISDICTION.
GRAVEL AREAS
1. ALL GRAVEL AREAS DAMAGED OR REMOVED BY THIS WORK SHALL BE REPLACED WITH CRUSHED SURFACING TOP COURSE IN
ACCORDANCE WITH THE REQUIREMENTS OF EACH JURISDICTION.
SITE RESTORATION
1. ALL DISTURBED OR DAMAGED AREAS SHALL BE RESTORED TO A CONDITION EQUAL TO, OR BETTER THAN, THAT WHICH EXISTED
PRIOR TO PLACEMENT OF THE CONDUIT AND STRUCTURES.
2. VEGETATION REMOVED FOR THIS WORK SHALL BE REPLACED WITH IN-KIND PLANT MATERIAL AND SHALL BE PROPERLY PLANTED
AND WATERED IN TO ENSURE ITS SURVIVAL.
3. SITE RESTORATION SHALL INCLUDE REPLACING EXISTING CABLING AND PULL ROPES IN EXISTING CONDUITS AS THEY EXISTED
PRIOR TO CONSTRUCTION.
WATER QUALITY
1. CONSTRUCTION ACTIVITIES OCCURRING ADJACENT TO STORM DRAINAGE STRUCTURES SHALL COMPLY WITH THE STATE OF
WASHINGTON'S WATER QUALITY STANDARDS
2. THE CONTRACTOR SHALL LIMIT THE USE OF PETROLEUM PRODUCTS ON THE SITE.
DIRECTIONAL BORING
1. WHEN BORING ROADWAYS, INSTALL (1) 4" SCHEDULE 40 PVC CONDUIT WITH PULL ROPES AND PLUGS.
2. PROTECT EXISTING UTILITIES -- COORDINATE WITH LOCAL JURISDICTIONS TO POTHOLE AS REQUIRED TO LOCATE EXISTING
UTILITIES.
FIRE PROTECTION
1. ALL INSTALLED BACKBOARDS SHALL BE PAINTED WITH FIRE-RESISTANT PAINT.
2. ALL FIRE SEALED DUCT ENDS AND CORES SHALL BE 2 HOUR FIRE-RATED. ALL FIRE SEAL IN EXISTING LOCATIONS SHALL BE
REPAIRED OR REPLACED UPON DUCT OR CABLE PLACEMENT.
AERIAL INSTALLATION
1. ALL AERIAL CONSTRUCTION IS TO BE PERFORMED TO INDUSTRY ACCEPTABLE STANDARDS.
2. ALL NEW AERIAL (AND EXISTING) CABLE HEIGHTS OF ATTACHMENT TO BE DOCUMENTED AT TIME OF CONSTRUCTION.
3. 6.35 MM STRAND TO BE USED WITH STANDARD 1/4" POLE LINE HARDWARE UNLESS OTHERWISE SPECIFIED. BOND STRAND TO
POWER MAIN WHERE APPLICABLE.
4. ALL ANCHORS TO BE USED WILL BE 3/4" SCREW TYPE.
5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN AND FOLLOW ALL NESC CODES ALONG
WITH APPLICABLE LOCAL AND REGIONAL GOVERNING AUTHORITIES. ANY DISCREPANCIES BETWEEN
THESE AUTHORITIES AND OR THE CONSTRUCTION PERMITS IS TO BE VALIDATED WITH THE
DESIGNER OR ENGINEER PRIOR TO CONSTRUCTION.
OF
APPROVED BY:
PROJECT CODE:
DRAWN BY:
DATE:
SCALE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0000845743WAKVD02K00 1X2-WAKVD02G00 2X4 (R25A 2X2)N 43RD ST & LAKE WASHINGTON BLVD NRENTON, WA 98056NODE SEGMENTATION17-050
2/9/2022
JBL
CS
NTS
0 0 0
2
416/3/2022SPLIT PERMIT INTO MUTIPLE PARTSJBLGENERAL NOTES
MFP22003041
OF
APPROVED BY:
PROJECT CODE:
DRAWN BY:
DATE:
SCALE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0000845743WAKVD02K00 1X2-WAKVD02G00 2X4 (R25A 2X2)N 43RD ST & LAKE WASHINGTON BLVD NRENTON, WA 98056NODE SEGMENTATION17-050
2/9/2022
JBL
CS
NTS
0 0 0
3
416/3/2022SPLIT PERMIT INTO MUTIPLE PARTSJBLLEGEND
EDGE OF PAVEMENT
FOGLINE
POWER
COMMUNICATION
SEWER
DRAIN
DRAINAGE DITCH
GAS
WATER
TRAFFIC SIGNAL
TELCOM
STEAM
UNKNOWN UTILITY
RIGHT OF WAY
TRAFFIC CONES
PROPOSED NEW BORE
STRAW WATTLES
P
LT
CW
R
UTILITY POLE
VAULT - SMALL
PEDESTAL
STREET LIGHT
CROSSWALK LIGHT
UTILITY RISER
V VAULT - SMALL
444LA MANHOLE
VAULT - 25TA
CATCH BASIN
CATCH BASIN WITH SOCK
GLULAM UTILITY POLECENTER LINE
LANE LINE
FENCE
HIGH VISIBILITY FENCE
S SEWER MANHOLE
D DRAIN MANHOLE
W WATER MANHOLE
V UTILITY VALVE
SHRUBBERY
BORE PIT
VAULT - LARGE
VAULT - 25TA
C COMMUNICATION MANHOLE
FIRE HYDRANT
DISTANCE STATIONSTA 0+00
CONSTRUCTION NOTE CALLOUT#
X.X DISTANCE DIMENSION
ASPHALT SURFACE
CONCRETE ROADWAY PANEL
HF H-FRAME
VAULT - LARGE
CAB CABINET
LEGEND
LANE DIRECTION INDICATOR
PROPOSED
MARK-UP NOTATIONS RESTORATION TYPESEXISTING FEATURESLINE TYPES
A
7
LANDSCAPE
CROSS SECTION SYMBOL
CROSS SECTION NAME
CROSS SECTION SHOWN ON PAGE
FL FL
P P
TS TS
C C
D D
DD DD DD DD DD
G G
W W
T T
ST ST
ROW ROW
S
UK
CB
CB
P P
V V V
V VV
WORK BEING DONE1LOCATION PHOTO NOTE CALLOUT
#PHOTO LOCATOR SYMBOL
PROPOSED NEW TRENCH
EXISTING UNDERGROUND PATHWAY
PROPOSED NEW AERIAL STRAND
EXISTING AERIAL PATHWAY
EXISTING SPLICE CASE
PROPOSED SPLICE CASE
EXISTING FIBER/COAX STORAGE
PROPOSED FIBER/COAX STORAGE
TREE
EOP
V VAULT - SMALL
444LA MANHOLE
VAULT - 25TA
VAULT - LARGE
EXISTING - CONTINUED
233LA MANHOLE
233LA MANHOLE
MFP22003041
4350
4101
4107
4113
4119
4125
4151
4157
4163
4169
4175
4205
4211
4217
4223
4229
4235
4255
4261
4267
1000
1006 1012 1018
1024 1030
1036 1102 1108 1114 1120 1126 1210 1216 1222 1228 1234 1240
1246 1252
1007 1013 1019 1025 1031 1037 1103 1109 1115 1121
1211 1217 1223 1229 1235 1241
1002
1008
1014
1020
1026
1032
1038
1104
12041132
1110
1116
1122
1128
1003
1009
1015
1021
1027
1033
1039
1111
1117
1123
1129
1219
4122
4118
4112
4106
1225 1231
4109
4115
4121
4127
1213
1207
1201
0
0
0
0
0
0
1105 LAKE WASHINGTON BLVD NN 42ND PLN 42ND PL
WILLIAMS AVE NN 41ST
P
L
WILLIAMS AVE N
EOPEOPEOPEOPEOP
EOPEOPEOP
EOP
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP
EOPEOPEOP
EOP
EOPEOPEOPEOP
EOPEOPEOPEOP
EO
P
EO
P
EOP
EOPEOPEOPEOPEOPEOPEOP
EOP
EOP
EOP
EOP EOP EOP EOP EOP EOPEOP
EOPEOPEOPEOP EOP
EOP
EOP
EOP
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOP
EOPEOPEOPEOPEOP
EOP
EOP EOPEOPEOPEOP
EOP
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEO
P
EOP
EOP
EOP EOPEOPEOPEOP
EOP
EOP
EOP
EOP
EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP
EOP
EOP
EOP
EOP
EOP
EOP EOP EOP
EOP
EOP
EOP EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPASPHALTASPHALTASPHALTASPHALTSIDEWALK SIDEWALK SIDEWALK SIDEWALK
SIDE
WALK
SIDE
W
ALK
SIDE
W
ALK
SIDEWALK
SIDEW
A
L
K
SIDE
W
A
LK
SIDEWALK
SIDE
W
A
LK
SIDE
W
ALK
SIDEWALK
SIDEWALK
SIDEWALK
SIDEWALK
SIDEW
ALK
SIDEWALK
SIDE
W
ALK
SIDEWALK
SIDE
W
ALK
SID
E
W
A
L
K
SIDEWALKSIDEW
A
L
K SIDEWALK
LANDSCA
P
E
SIDEW
A
L
K
SIDEW
A
L
KSIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALK
SIDEWALK
SIDEWALKSIDEWA
LK SIDEWALKSIDEWA
LKSIDEWA
LK
SIDEWA
L
K
SIDEWA
L
K
SIDEWA
L
K
SIDEWALK
SIDEWALK SIDEWAL
KSIDEWALK SIDEWALKSIDEWALKSIDEWALKSIDEWALK
SIDE
W
A
L
K
SIDEWALKSIDEWALKSIDEWALK
SIDEWALK SIDEWALK SIDEWALK SIDEWALK
SIDEWALK SIDEWALK
SIDEWA
L
K
SIDE
W
A
L
K
SID
E
W
A
L
K
SIDE
WA
LK
LANDSCAPE
LANDSCAPELANDSCAPE
LANDSCAPELANDSCAP
E
LANDSCAP
E
LANDSCA
P
E
LANDSCAPE LANDSCAPELANDSCAPE
LANDSCAPE
LAND
S
C
A
P
E
LANDSCAPE LANDSCAPE
LANDSCAPE LANDSCAPE
LANDSCAPE LANDSCAPE
LANDSCAPE
LANDSCAPE
LANDSCAPE
LANDSCAPE
LAND
S
C
A
P
E
LANDSCAPE
GRASS
GRASS
GRASS
GRASS
LANDSCAPE LANDSCAPELANDSCAPELANDSCA
P
E
LAND
S
C
A
P
E
LAND
S
C
A
P
E
LAND
S
C
A
P
E
LANDSCAPE
LANDSCAPELANDSCAPE
LANDSCAPE
LANDSCAPE
LANDSCAPE
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVEWAY
DRIVE
W
A
Y
DRIVEW
A
Y
DRIVE
W
A
Y
DRIVE
W
A
Y
DRIVEW
A
Y
DRIVEW
A
Y
DRIVEWAY
DRIVEWAY
DRIVEWA
Y
DRIVEWAY
DRIVEW
A
Y
DRIVEW
A
Y
DRIVEWAY
DRIVE
W
A
Y
DRIVEWAY
DRIVE
W
A
Y
DRIVEWA
Y
DRIVEWA
Y
DRIVEWA
Y
DRIVEWA
Y
DRIVEWA
Y
DRIVEW
A
Y DRIVEWAY
DRIVE
W
A
Y
DRIVEWA
Y
DRIVEWA
Y DRIVEWAY DRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAY
EOP EOP EOP EOP
EOPEOPEOPEOPASPHALTASPHALT
ASPHALT
ASPHALT
ASPH
A
L
T
ASPH
A
L
T
ASPHAL
T
ASPHA
L
T
ASPHALT
ASPHALT ASPHALTASPHALT
ASPHALT
ASPHALT
ASPH
ALTASPHALT
ASP
H
A
L
T
ASPH
A
L
T
ASP
H
A
L
T
ASPH
A
L
T
ASP
H
A
L
T
ASPH
A
L
T
ASPHALTASPHALT
ASPHAL
T
ASPHALT
ASPHA
LT
ASPH
A
LT
ASPHAL
T
ASPHALT
ASPHALTASPHAL
T
ASP
H
A
L
T
ASP
H
A
L
T
ASP
H
A
L
T
ASP
H
A
L
T
ASPHA
LTASPHALT
ASPHAL
T
ASPHA
L
T
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHAL
T
ASP
H
A
L
T
ASPHALTASPHALTASPHALTASPHALTSIDE
WALK
R
25'
PLACE 1X2 RPHY
NODE HERE
SPLICE INTO EXISTING
SPLICE CASE;
WAKVD02K01_SP0120.WAKV
UPGRADE TO TIGER HOUSE
FOR NODE PLACEMENT
TIE INTO SPLICE
CASE SP.WAKV.0426
PLACE 48CT SHEATH 200'
STORAGE EVERY 1500'
PULL 48 CT FIBER IN
EXISTING CONDUIT,
(TYPICAL)
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROWROWROW
ROW ROW
ROW
ROW ROW
ROW
ROW ROW
ROW ROW
ROW
ROW ROW
ROW
ROW ROW
ROW
ROW
ROW
ROW ROW
ROW
ROW ROW
ROW
ROW
ROW
ROW ROW
ROW
ROW ROW
ROW
ROW ROW
ROW ROW
ROW
ROW ROW
ROW
ROW ROW
ROW
ROW
ROW
ROW ROW
ROW
ROW ROW
ROWROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROWROWROWROWROWROW ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW ROWROWROWROWROWROW
ROW ROW ROW ROW ROW ROW
ROW
ROW
ROW
ROW ROW
ROW
ROW
ROW
ROW ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW
ROWROWROWROWROWROWROWROWROW
ROWROWROWROWROWROW
ROWROWROWROWROWROWROWROWROWROWROWV
V
V
55'200'
PLACE 48CT SHEATH
200' STORAGE @ RISER75'200'100'
100'
140'
2
0
0
'100'203'
85'
100'
156'
120'110'350'25'
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DH
P
P
P
P
P
P
P
P P
P
P
P
SIDEWA
L
K
P
P
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FLFL
FL
FL
FL
FL
FLFL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL FLFL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FLFL
FL
FL
FL
FL
FL
FL
FL FL FL FLFL
FL
FL
FL
FL
FL
FL
FL FL FL FL FL FL FL
FL
FL FL FL
FL
FL
FL FL FL
FL
FL
FL
FL FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL FL FL FL FL FL FL FL FL
FL
FL
FL
FL
FL
FL
FL FL
FL
FL
FL FL FL
FL
FL
FL
FL FL FLFL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FLEOP
DRIVEWAY
DRIVEWAY
OF
APPROVED BY:
PROJECT CODE:
DRAWN BY:
DATE:
SCALE:PROJECT REVISIONSREVDESCRIPTION OF CHANGEDATEBYQCJB0000845743WAKVD02K00 1X2-WAKVD02G00 2X4 (R25A 2X2)N 43RD ST & LAKE WASHINGTON BLVD NRENTON, WA 98056NODE SEGMENTATION17-050
2/9/2022
JBL
CS
1:80
0'40'80'
4
416/3/2022SPLIT PERMIT INTO MUTIPLE PARTSJBLDESIGN
N
MFP22003041
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Conditions for Permit MFP22003041
Engineering
1 Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking
place.
2 Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial
lines within the Project Reach must have a minimum vertical clearance of 15'-6".
3 A traffic control plan must be separately submitted to the City, and no construction may take place until the City
has approved a traffic control plan.
4 The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at the
Applicant’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the
Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case the
Applicant shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or
(3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial
lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and
Economic Development Administrator or designee, from the first event triggering the requirement to underground
the aerial lines.
Page 1 of 1