Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutEx04_Floor_PlansDN
DN
WELDING
STORES
STORES
MECHANICS PREVENTATIVE MAINTENANCE
TRAILER
SCAFFOLD
INSPECTIONS
SHIPPING
# 2B PROPOSED OFFICE
MODULAR
# 31B
PROPOSED
OFFICE
MODULAR
TRUCK ACCESS
1
A3.02
REFUSERECYCLING7
17
4
433
4
2
6
8 3
4
26812
15
9711(E) MODULAR
TO REMAIN
10
18
225
21
10 620
11
11
1313131313131313
1414
141414141422
19
20
20 20
12 20' - 6"57' - 3"33' - 10"74' - 4"25' - 0"42' - 10"34' - 11"25' - 1"28' - 9"30' - 6"9' - 6"114' - 10"
WELDING
A3.02
4
A3.02
3
A3.022
2423
0' - 0"
0' - 0"
0' - 0"
0' - 0"
-3' - 6"
-3' - 6"
-4' - 0"0' - 0"
88 42525(E) FLOOR DRAIN
TO BE SEALED
20
PROPOSED TEMPORARY FLOOR OVER EXISTING LOADING
BAY, SEE STRUCTURAL DRAWIGNS FOR ADDITIONAL
INFORMATION. NO ACCESS TO AREA BELOW PROPOSED
TEMPORARY FLOOR. NO STORAGE, NO FLAMMABLE
MATERIALS ON TOP OR BELOW PROPOSED DECK
PROPOSED 8'-0"H CHAIN LINK SECURITY FENCE
PROPOSED TRANSACTION DESK
KEY NOTES
1
2
3
PROPOSED 4'-0" SINGLE GATE -CHAIN LINK, LOCKABLE
PROPOSED 8'-0" DOUBLE GATE -CHAIN LINK, LOCKABLE
PROPOSED AMCRAFT WAREHOUSE INDUSTRIAL CURTAIN
WALLS OR APPROVED EQUAL
(E) ROLL-DOWN WAREHOUSE DOOR TO BE FIXED IN PLACE
ABOVE NEW PASSAGE DOOR. INFILL WALL TO RIGHT AND
LEFT OF NEW PASSAGE DOOR.
4
5
6
7
PROPOSED STORAGE. NO STORAGE OR STORED ITEMS TO
EXCEED 12'-0" IN HEIGHT PER RENTON FIRE AUTHORITY.
(E) ELECTRICAL PANEL, VIF.
EXTERIOR SUPPORT STORAGE
(E) BUILDING ENVELOPE TO REMAIN
INSPECTION RAMPS AREA
8
9
10
11
(E) DOOR TO REMAIN
PROPOSED DOWNSPOUT & FILTER BARREL
PROPOSED METAL RAMP AT 1:12 SLOPE
PROPOSED METAL STAIR
(E) STAIR TO BE CLOSED OFF
(E) SPRINKLER ROOM TO REMAIN
13
14
15
16
(E) GENERATOR TO REMAIN
VEHICLE MAINTENANCE AREA
PICK UP AND BOX TRUCK BACK-IN
PROPOSED GUARDRAIL
EQUIPMENT WASH PAD
PRESSURE WASH EQUIPMENT (T9)
19
12
17
20
21
22
METAL STORAGE CABINET
USED ANTIFREZE
SCRAP METAL SHREDDER
TIRE WASH
ROLL OFF DUMPSTER
AIR COMPRESSOR
25
18
23
24
T10
W27, W34
T8
W29
T16
CURTAIN
PLAN LEGEND
SECURITY FENCE
Project No.
Checked:
Drawn:
Design:
Issuance
Drawing Title
105 S. Main St. Seattle, WA 98104
p. 206.624.4222 f. 206.624.4226
www.rolludaarchitects.com
REVISION DATEOWNER:COPYRIGHT © 2018 ROLLUDA ARCHITECTS INC
Drawing Number
C:\Users\jess\Documents\FarWest-v2020_nes@rolludaarchitects.com.rvt 4/1/2022 10:34:15 AM
A2.00
FLOOR PLANS
LAND USEInterim Maintenance Facility Improvements atFarwestADDRESS201 SW 34th St #4939, Renton, WA 98057KING COUNTY SOLID WASTE DIVISION201 S JACKSON ST UNIT 5701SEATTLE, WA 98104TEL:(206) 477-4466DS
JL, PA, FA
DS
3/31/22
SCALE:1/16" = 1'-0"1 WAREHOUSE FLOOR PLAN
04/12/22
STORES (WAREHOUSE)
STORES (WAREHOUSE)
EXHIBIT 4
DocuSign Envelope ID: E5547EDD-1825-4B24-9DC9-B3EFAE58C2CD
DN
DN
DN
MODULAR LEGEND
PROPOSED BLDG 2B: (6) 8'X6' WORK STATIONS
PLAN LEGEND:
EXISTING (E) TO REMAIN
EXISTING TO BE DEMOLISHED
NEW
1. FIELD VERIFY ALL DIMENSIONS AND EXISTING
CONDITIONS PRIOR TO PROCEEDING WITH THE WORK.
2. FIELD VERIFY LOCATION OF ALL ELECTRICAL &
MECHANICAL FEATURES TO REMAIN, SEE ELEC. / MECH.
DRAWINGS.
3. REPAIR FLOOR & CURBS AFTER REMOVAL OF EXISTING
MATERIAL AS NEEDED BEFORE STARTING THE WORK.
4. WHERE EXISTING WORK IS DAMAGED, CUT OR DEFACED
AS A RESULT OF PERFORMANCE OF NEW WORK, THE
CONTRACTOR IS TO PATCH AND REPAIR SAME TO
MATCH ADJOINING SURFACES.
5. REFER TO MATERIAL SCHEDULES & FINISHES.
6. REFER TO CIVIL / MECH / ELEC DRAWINGS FOR WORK
NOT SHOWN ON ARCHITECTURAL SHEETS.
PLAN NOTES
KEY NOTES
1
2
PROPOSED MODULAR ENVELOPE TO BE REPAINTED
WINDOW, SEE SCHEDULE
DOOR, SEE SCHEDULE
PROPOSED DOWNSPOUT & FILTER BARREL
PROPOSED METAL WALKWAY & GUARDRAILS
PROPOSED METAL RAMP AT 1:12 SLOPE
PROPOSED METAL STAIR
OWNER-PROVIDED FURNITURE, PROPOSE USING
EXISTING KC INVENTORY
EXISTING (E) ROLL-DOWN WAREHOUSE DOOR TO
BE FIXED IN PLACE ABOVE NEW PASSAGE DOOR.
INFILL WALL TO RIGHT AND LEFT OF NEW PASSAGE
DOOR.
EXISTING (E) FORMER WAREHOUSE BUILDING TO
REMAIN
NEW TEMPORARY FLOOR OVER EXISTING LOADING
BAY, SEE STRUCTURAL DRAWINGS FOR ADDITIONAL
INFORMATION
PROPOSED BOLLARD, PAINTED YELLOW TO MATCH
EXISTING
(E) LOCKER/BREAK BUILDING TO REMAIN
(E) BOLLARD TO REMAIN
(E) ENCLOSURE TO BE REPLACED
5
4
#
3
6
7
8
9
10
11
12
13
14
OFFICE 6
12' - 0"
3' - 8"10' - 1"9' - 6"9' - 6"9' - 6"8' - 0"10' - 0"10' - 0"24' - 3"7' - 2"OFFICE 5
OFFICE 4
OFFICE 3
OFFICE 2
OFFICE 1
2
A3.01
1
A3.01
4
A3.01
3
A3.01 12
3
5
7' - 3"9' - 6"9' - 0"4
6
2
2
2
2
2
2
2
359' - 5"7
7
7
7
7
789
6
9 1010
1:12119INFILL (E) OPENING
1:122' - 6"24' - 0"30' - 0"
OPEN OFFICE
6' - 0"17' - 8"6' - 4"
2' - 4"5' - 7"15' - 9"6' - 4"
6
A3.01
5
A3.01
7
A3.01
1
4
5
2
3
4WALKWAY
CONNECTS TO (E)
MODULAR ACCESS
5 96 631:12
1:121:121:129999 999A3.01 68
Project No.
Checked:
Drawn:
Design:
Issuance
Drawing Title
105 S. Main St. Seattle, WA 98104
p. 206.624.4222 f. 206.624.4226
www.rolludaarchitects.com
REVISION DATEOWNER:COPYRIGHT © 2018 ROLLUDA ARCHITECTS INC
Drawing Number
C:\Users\jess\Documents\FarWest-v2020_nes@rolludaarchitects.com.rvt 3/3/2022 1:06:17 PM
A2.01
FLOOR PLANS
PERMIT DRAFTInterim Maintenance Facility Improvements atFarwestADDRESS201 SW 34th St #4939, Renton, WA 98057KING COUNTY SOLID WASTE DIVISION201 S JACKSON ST UNIT 5701SEATTLE, WA 98104TEL:(206) 477-4466DS
JL, PA, FA
DS
3/14/22
NN
SCALE:1/4" = 1'-0"2 BLDG 2B
SCALE:1/4" = 1'-0"1 BLDG 31B
LAND USE
3/31/2204/12/22
DocuSign Envelope ID: E5547EDD-1825-4B24-9DC9-B3EFAE58C2CD