HomeMy WebLinkAboutPRE22-000218_Meeting SummaryPREAPPLICATION MEETING FOR
Benson and Petrovitsky Redevelopment
PRE 22-000218
CITY OF RENTON
Department of Community & Economic Development
Planning Division
July 14, 2022
Contact Information:
Planner: Jill Ding, 425.430.6598, jding@rentonwa.gov
Public Works Plan Reviewer: Michael Sippo, 425-430-7298, msippo@rentonwa.gov
Fire Prevention Reviewer: Corey Thomas, 425.276.9582, cthomas@RentonRFA.org
Building Department Reviewer: Rob Shuey, 425.430.7235
Please retain this packet throughout the course of your project as a reference. Consider
giving copies of it to any engineers, architects, and contractors who work on the
project. You will need to submit a copy of this packet when you apply for land use
and/or environmental permits.
Pre-screening: When you have the project application ready for submittal, call and
schedule an appointment with the project manager to have it pre-screened before
formal submittal.
The pre-application meeting is informal and non-binding. The comments provided on
the proposal are based on the codes and policies in effect at the time of review. The
applicant is cautioned that the development regulations are regularly amended and the
proposal will be formally reviewed under the regulations in effect at the time of project
submittal. The information contained in this summary is subject to modification and/or
concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director,
Development Services Director, Department of Community & Economic Development
Administrator, Public Works Administrator and City Council).
M E M O R A N D U M
DATE: June 28, 2022
TO: Jill Ding, Senior Planner
FROM: Corey Thomas, Lead Plans Review Inspector
SUBJECT: Benson & 176th St SE
1. The preliminary fire flow is 2,000 gpm. A minimum of one hydrant is required within 150-
feet of each structure and one additional hydrant is required within 300-feet of each
structure. A water availability certificate is required from Soos Creek Water District .
Existing fire hydrants that meet these criteria can be used to satisfy the requirements.
2. Fire impact fees are applicable at the rate of $0.26 per square foot of commercial
bank/office space and $1.25 per square foot of retail space. No charge for gas station
canopy. This fee is paid at time of building permit issuance. Credit will be granted for the
area of total buildings removed.
3. Approved fire alarm systems are required throughout all buildings of 3,000 square feet or
more. Separate plans and permits required by the fire department. Fully addressable
and full detection is required for the fire alarm system. Fire sprinklers are not required in
the proposed buildings.
4. Fire department apparatus access roadways are required within 150-feet of all points on
the building. Fire lane signage required for the on-site roadways. Required turning
radiuses are 25-feet inside and 45-feet outside. Roadways shall be a minimum of 20-feet
wide. Roadways shall support a minimum of a 30-ton vehicle and 75-psi point loading.
5. Separate plans and permits are required to be submitted to and obtained from the Renton
Regional Fire Authority for all new underground gasoline tanks and tank monitoring
systems.
DEPARTMENT OF COMMUNITY
& ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: 07/13/2022
TO: Jill Ding, Senior Planner
FROM: Michael Sippo, Civil Engineer III, Plan Review
SUBJECT: Benson & 176th Commercial Redevelopment
17426 108th Ave SE & 10810, 10828 SE Petrovitsky Rd
PRE22-000218
NOTE: The applicant is cautioned that information contained in this summary is preliminary and
non-binding and may be subject to modification and/or concurrence by official City decision-
makers. Review comments may also need to be revised based on site planning and other design
changes required by City staff or made by the applicant.
I have completed a preliminary review for the above-referenced proposal located at parcel(s)
292305-9017, 9095 and 9110. The following comments are based on the pre-application submittal
made to the City of Renton by the applicant.
WATER
1. The subject development is within the water service area of Soos Creek Water and Sewer
District. A water availability certificate from Soos Creek Water and Sewer District is
required as part of the Land use Application.
2. A copy of the water main improvements plans, shall be submitted to the City of Renton
as a part of the City’s Civil Construction permit.
3. The number and locations of fire hydrants shall be determined by the Renton Regional
Fire Authority as part of the review of the project plans.
4. The site is located outside of an Aquifer Protection Area.
Benson & 176th redevelopment PRE22-000218
July 13, 2022
Page 2 of 9
SEWER
1. The subject development is within the water service area of Soos Creek Water and Sewer
District. A sewer availability certificate from Soos Creek Water and Sewer District is
required as a part of the Land use Application.
2. A copy of the sewer main improvement plans shall be submitted to the City of Renton as
a part of the City’s Civil Construction permit.
3. An oil/water separator will be required for connecting any covered parking to sewer.
4. A grease interceptor is required if there is a commercial kitchen. The grease interceptor
shall be sized based on drainage fixture units in accordance with standards found in the
latest edition of the Uniform Plumbing Code (UPC). The grease interceptor shall drain by
gravity to the sewer main.
5. If any of the existing buildings on the site are served by private on-site septic systems, the
septic systems shall be abandoned in accordance with King County Department of Health
regulations and Renton Municipal Code.
SURFACE WATER
1. A drainage report complying with the current Renton Surface Water Design Manual
(RSWDM) will be required. The current 2022 City of Renton Surface Water Design
Manual (RSWDM) can be accessed from the City of Renton website.
2. Based on the City’s flow control map, the site falls within the Flow Control Duration
Standard area matching Forested Site Conditions. The site falls within the Black River
Drainage Basin. Refer to Figure 1.1.2.A – Flow chart to determine the type of drainage
review required in the RSWM. The Figure 1.1.2.A should be included in the drainage
report submitted with the land use application. The site is located outside of any
Aquifer Protection Zone area.
3. The existing site topography slopes from south-east to north-west. There is a small
portion of regulated slope near the north property line of 10828 SE Petrovitsky
Road. There is existing private on-site stormwater conveyance connection from 10810
SE Petrovitsky Road, and 10828 SE Petrovitsky Road to the existing 12-inch diameter
corrugated metal pipe stormwater main (Facility ID 118859) in their SE Petrovitsaky
Road frontage. There is an existing 12-inch diameter concrete stormwater main in both
108th Ave SE frontage and SE Petrovitsky Road frontage of 17426 108th Ave SE.
4. Storm drainage improvements along all public street frontages are required to conform
to the City’s street and stormwater conveyance standards. Any new storm drain
installed on or off-site shall be designed and sized in accordance with standards found in
Chapter 4 of the 2022 RSWDM and shall account for the total upstream tributary area,
assuming developed conditions for onsite tributary areas and existing conditions for any
offsite tributary areas.
5. If the new plus replaced pollution generating impervious surface exceeds 5,000 SF, the
applicant will be required to provide enhanced basic water quality treatment for the
Benson & 176th redevelopment PRE22-000218
July 13, 2022
Page 3 of 9
commercial project. Any proposed detention and/or water quality vault shall be
designed in accordance with the RSWDM that is current at the time of civil construction
permit application. Separate structural plans will be required to be submitted for
review and approval under a separate building permit for the detention and/or water
quality vault.
6. On-site BMPs satisfying Core Requirement #9 will be required for the site to the maximum
extent feasible. On-site BMPs shall be evaluated as described in Section C.1.3 of the 2022
RSWDM. Appropriate flow control BMPs will be required to help mitigate the new runoff
created by this development. A preliminary drainage plan, including the application of
flow control BMPs, shall be included with the land use application, as applicable to the
project. The final drainage plan and drainage report must be submitted with the utility
construction permit application.
7. Effective June 22, 2022, the City of Renton has adopted the 2022 RSWDM, which is
based on the 2021 King County SWDM. Under the new 2022 RSWDM stormwater
requirements, on-site BMP sizing credits for modeling credits can no longer be used for
privately maintained on-site BMPs, with the exception of full dispersion and full
infiltration BMPs.”
8. A geotechnical report for the site is required and shall be submitted with the land use
application. Information concerning the soils, geology, drainage patterns, vegetation
present, water table and soil permeability, with recommendations of appropriate on-
site BMP options with typical designs for the site from the geotechnical engineer, shall
be submitted with the application. The geotech report should include an on-site
infiltration test to clearly show if the site is suitable or unsuitable for infiltration. The
geotech report should discuss critical areas in the site and if there any wet season
construction restrictions.
9. Erosion control measures to meet the City requirements shall be provided.
10. A Construction Stormwater General Permit from Department of Ecology will be required
if grading and clearing of the site exceeds one acre. A Stormwater Pollution Prevention
Plan (SWPPP) is required for this site.
11. The current Surface Water Standard Plans shall be used in all drainage plan
submittals. The current City of Renton Standard Details is available online in the City
of Renton website.
12. The 2022 Surface water system development fee is $0.84 per square foot of new
impervious surface, but not less than $2,100.0. This is payable prior to issuance of the
construction permit. This fee is subject to change based on the calendar year the
construction permit is issued. The fee information for City permits that will be issued in
2022 is available online from the City of Renton Fee Schedule
TRANSPORTATION
1. Street and frontage requirements: The proposed development site has frontage on SE
Petrovitsky Road (176th St SE) and on 108th Ave SE ( Benson Road/ SR 515).
• SE Petrovitsky Road (176th St SE) is a five lane Principal Arterial. Per the King County
Assessor map, the existing half street ROW width on the site frontage is
approximately 30 feet. Per Renton Municipal Code (RMC) 4-6-060, the minimum
Benson & 176th redevelopment PRE22-000218
July 13, 2022
Page 4 of 9
ROW width required on a five lane principal arterial is 103 feet. However,
Transportation Division has preliminary plan along SE Petrovitsky Rd, which will
require street frontage improvements including an additional 11-feet wide right-
turn only lane, a 0.5-foot wide curb, an 8-foot wide landscaped planter, a 12-foot
wide ped/ bike path, and a 2-foot clear area from back of the path to the new ROW
line. The street and frontage section will require varying ROW dedication along the
frontage of the 3 parcels. The ROW dedication width of approximately 33.5 feet
(subject to final survey) in front of parcel 10810 SE Petrovitsky Road and varying
ROW dedication if the frontages of parcels 17426 108th Ave SE and 10828 SE
Petrovitsky Road. ROW dedication and street frontage improvements are required
to be provided by the developer. A street section showing and labelling the existing
ROW line, centerline of ROW, ROW dedication, centerline of pavement, pavement
width, showing and labelling all the street frontage elements and widths should be
included with the land use application.
• The access from SE Petrovitsky Rd will be restricted to right-in right-out only access
(no left turns). C-curbing will be required to be provided on SE Petrovitsky Road to
prevent left turns to the site access.
• 108th Ave SE (Benson Road/ SR 515) - is a Principal Arterial. Per King County
Assessor map, the existing half street ROW width on the site frontage is
approximately 45 feet. Street frontage improvements in the Transportation Division
preliminary plan, on the east side of 108th Ave SE/Benson Rd/SR 515, include
roadway widening to provide an 11-foot wide acceleration lane, and a 0.5-foot wide
curb with a gutter. An 8-foot wide landscaped planter, 8-foot wide sidewalk, and 2 -
foot clear width back of sidewalk are street frontage improvements per RMC 4-6-
060. ROW dedication of varying width (width also depends on the status of the
billboard) will be required in front of parcel 2923059110 to accommodate these
frontage improvements. The Transportation Division plan also includes driveway
access for this parcel. ROW dedication and street frontage improvements are
required to be provided by the developer. A street section showing and labelling
the existing ROW line, centerline of ROW, ROW dedication, centerline of pavement,
pavement width, showing and labelling all the street frontage elements and widths
should be included with the land use application.
• The access from 108th Ave SE to this site will be restricted to right-in right-out only
(no left turns). The existing C-curbing on Benson Rd/SR 515 will be retained to
prevent left turns in to and out of the site access.
2. A minimum intersection radius of 35 feet is required at the intersection SE Petrovitsky
Road (176th St SE) and on 108th Ave SE (Benson Road/ SR 515).
3. On and off-site ADA (including the street frontages), curbing, sidewalk and parking
lot/drive-aisle improvements will be reviewed in conjunction with the civil construction
permit for the project and will require a grading plan consisting of spot elevations and
slopes showing that ADA and City specifications are being met.
4. Property corner dedication meeting City code is required to be provided.
5. Street lighting and street trees are required to meet current city standards. Lighting
plans are required to be submitted with the land use application and will be reviewed
during the construction utility permit review.
Benson & 176th redevelopment PRE22-000218
July 13, 2022
Page 5 of 9
6. Undergrounding of all existing and proposed utilities is required on all frontages per
RMC 4-6-090.
7. Paving and trench restoration will comply with the City’s Trench Restoration and
Overlay Requirements.
8. A traffic impact analysis is required when the estimated vehicular traffic generated from
a proposed development exceeds 20 vehicles per hour in either the AM (6:00 – 9:00) or
PM (3:00 – 6:00) peak periods. Traffic study guidelines are included with the pre-
application packet. The analysis must include a discussion on traffic circulation to and
from the site and onsite traffic circulation. The study shall include trip generation and
trip distribution for the project for both AM and PM peak hours.
9. Payment of the transportation impact fee is applicable on the buildings at the time of
building permit and is based on the type of use of the building. The transportation
impact fee information for City permits that will be issued in 2022 are available from the
City of Renton Fee Schedule available online in the City of Renton website. The fee is
subject to change and the transportation impact fee that is current at the time of
building permit application will be applicable.
GENERAL COMMENTS
1. All existing and proposed utility lines and poles (i.e. power, electrical, phone, and cable
services, etc.) along property frontage and within the site must be underground. The
construction of these franchise utilities must be inspected and approved by a City of
Renton inspector.
2. Maximum exposed retaining wall height is 6-ft and shall be setback a minimum of 3-ft
from the right-of-way as outlined in RMC 4-4-040 – Fences, Hedges and Retaining Walls.
3. Adequate separation between utilities as well as other features shall be provided in
accordance with code requirements.
a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other
utilities is required with the exception of water lines which require 10-ft
horizontal and 1.5-ft vertical.
b. The stormwater line should be minimum 5 feet away from any other structure or
wall or building.
c. Trench of any utility should not be in the zone of influence of the retaining wall
or of the building.
4. All civil construction permits for utility and street improvements will require separate plan
submittals. All utility plans shall confirm to the Renton Drafting Standards. A licensed Civil
Engineer shall prepare the civil plans. Please visit the Development Engineering Forms
page for the most up-to-date plan submittal requirements:
http://rentonwa.gov/business/default.aspx?id=42473
5. A landscaping plan shall be included with the civil plan submittal. Each plan shall be on
separate sheets.
6. Fees quoted in this document reflect the fees applicable in the year 2020 only and will be
assessed based on the fee that is current at the time of the permit application or issuance,
as applicable to the permit type. Please visit www.rentonwa.gov for the current
Benson & 176th redevelopment PRE22-000218
July 13, 2022
Page 6 of 9
development fee schedule.
7. A demo permit is required for the demolition of the existing building. The demo permit
shall be acquired through the building department.
POLICY GUIDELINES FOR TRAFFIC IMPACT ANALYSIS
FOR NEW DEVELOPMENT
A traffic impact analysis is required when estimated vehicular traffic generated from a proposed
development exceeds 20 vehicles per hour in either the AM (6:00 - 9:00) or PM (3:00 –6:00)
peak periods. A peak hour volume of 20 vehicles per hour would relate to daily volume of
approximately 200 vehicles per day. Generally this includes residential plats of 20 lots or more
and commercial sites that generate 20 vehicles per hour.
The developer shall select a registered professional engineer with adequate experience in
transportation planning and traffic engineering. Upon request, the Public Works Department
will offer potential candidates.
The analysis shall incorporate the following elements in the suggested format:
Introduction:
The introduction should, in a narrative fashion with graphics where appropriate to enhance the
text, describe the proposed development (including proposed time frame), establish study area
boundaries (study area should include all roadways and intersections that would experience a 5%
increase in peak hour traffic volumes as a result of the proposed development), describe existing
and proposed land uses within the study area, and describe the existing transportation system to
include transit routes, roadway and intersection conditions and configuration as well as currently
proposed improvements. Roadways and intersections to be analyzed will be determined through
coordination with the Public Works Department and Community Development staff.
Site Generated Traffic Volumes:
The analysis should present a tabular summary of traffic generated from the proposed
development listing each type of proposed land use, the units involved, trip generation rates
used (to include total daily traffic, AM peak hour and PM peak hour) and resultant trip
generation for the time periods listed.
The trip generation information provided in the traffic impact study must be based on the
current edition of the ITE Trip Generation book.
Site Generated Traffic Distribution:
The distribution of site-generated traffic should be presented by direction as a percentage of the
total site generated traffic in a graphic format. The basis for the distribution should be
appropriately defined.
Site Generated Traffic Assignment:
A graphic presentation should be provided illustrating the allocation of site-generated traffic to
the existing street network. The presentation should include Average Daily Traffic (ADT) and
AM-PM peak hour directional volumes as well as turning movements at all intersections,
driveways, and roadways within the study area
Existing and Projected Horizon Year Traffic Volumes With and Without the Proposed
Development:
The report should include graphics, which illustrate existing traffic volumes as well as forecasted
volumes for the horizon year of the proposed development. Forecasted volumes should include
a projected growth rate and volumes anticipated by pending and approved developments
adjacent to the proposed development. If the development is multi-phased, forecasted
volumes should be projected for the horizon year of each phase. The site-generated traffic
should then be added to the horizon year background traffic to provide a composite of horizon
year traffic conditions.
Condition Analysis:
Based upon the horizon year traffic forecasts with the proposed development, a level of service
(LOS) analysis should be conducted at all intersections (including driveways serving the site).
Based upon this analysis, a determination should be made as to the ability of the existing and
proposed facilities to handle the proposed development. The level of service (LOS) analysis
technique may include any of the commonly accepted methods.
An analysis should be made of the proposed project in light of safety. Accident histories in close
proximity to the site should be evaluated to determine the impact of proposed driveways and
turning movements on existing problems.
Mitigating Measures:
Based upon the results of the previous analysis, if it is determined that specific roadway
improvements are necessary, the analysis should determine what improvements are needed.
If the developer can reduce vehicular traffic by means of promoting transit and ridesharing usage,
these methods are acceptable.
Any proposed traffic signals should be documented with an appropriate warrant analysis of
conditions in the horizon year with the development. Traffic signals should not be contemplated
unless they meet warrants as prescribed in the Federal Highways “Manual on Uniform Traffic
Control Devices”. Proposed traffic signals shall provide coordination programs to compliment the
system.
Any modifications necessary to insure safe and efficient circulation around the proposed site
should be noted.
Conclusions:
This section should serve as an executive summary for the report. It should specifically define the
problems related directly to the proposed developments and the improvements necessary to
accommodate the development in a safe and efficient manner.
A draft report shall be presented to the Development Services Division so that a review might be
made of study dates, sources, methods, and findings. City Staff will then provide in writing all
comments to the developer. The developer will then make all necessary changes prior to
submitting the final report.
H:\CED\Development Services\Development Engineering\TIA GUIDELINES
Benson Petrovitsky Redevelopment– PRE21-000234
7/25/2021
Page 9 of 9
Page 9 of 9
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: July 14, 2022
TO: Pre-Application File No. PRE22-000218
FROM: Jill Ding, Senior Planner
SUBJECT: Benson & Petrovitsky Redevelopment
17426 Benson Dr S, 10811 & 10828 SE Petrovitsky Rd
(Parcel Nos. 2923059110, 2923059095, and 2923059017)
General: We have completed a preliminary review of the pre-application for the above-
referenced development proposal. The following comments on development and permitting
issues are based on the pre-application submittals made to the City of Renton by the applicant
and the codes in effect on the date of review. The applicant is cautioned that information
contained in this summary may be subject to modification and/or concurrence by official decision-
makers (e.g., Hearing Examiner, Community & Economic Development Administrator, Public
Works Administrator, Planning Director, Development Services Director, Development
Engineering Director, and City Council). Review comments may also need to be revised based on
site planning and other design changes required by City staff or made by the applicant. The
applicant is encouraged to review all applicable sections of the Renton Municipal Code. The
Development Regulations are available online at https://www.codepublishing.com/WA/Renton.
Project Proposal: The subject property consists of three (3) parcels located at the northeast
corner of the intersection of Benson Dr S/108th Ave SE and SE Petrovitsky Rd. The subject site is
approximately 1.68 acres (72,980 sf) and is zoned Commercial Arterial (CA). An existing auto repair
building and former fire station building are proposed for removal. The proposal is to develop the
site with a 2,850 sq. ft. bank, a 4,100 sq. ft. convenience store, and a 2,900 sq. ft. gas station
canopy (with 6 pumps). A total of 51 surface parking spaces would be provided and a public plaza
would be located at the intersection of Benson Dr S and Petrovitsky Rd. Access would be provided
via two curb cuts, one off of Benson Dr S/108th Ave SE and the other off of SE Petrovitsky Rd.
Slopes with grades less than twenty-five percent (25%) are mapped on the northeast corner of
the project site.
Current Use: Currently the site is developed with a former auto repair building and fire station,
proposed for removal.
1. Zoning /Land Use Designation, and Overlays: The property is located within the Commercial
& Mixed Use (CMU) land use designation and the Commercial Arterial (CA) zoning
designation. Retail sales, on-site services, and vehicle fueling stations are permitted uses in
the CA zone.
The property is located within Urban Design District ‘D’, and therefore subject to additional
design elements. Proposals should have unique, identifiable design treatment in terms of
Benson & Petrovitsky Redevelopment
Page 2 of 8
July 17, 2022
landscaping, building design, signage and street furniture. Design elements are listed in
RMC 4-3-100 for District ‘D’.
2. Development Standards: The project would be subject to RMC 4-2-120A , “Development
Standards for Commercial Zoning Designations” effective at the time of complete application
(noted as “CA standards” herein).
Minimum Lot Size, Width and Depth – There are no minimum requirements for lot width or
depth within the CA zone. The minimum lot size in the CA zone is 5,000 square feet. Each of
the three lots exceeds the minimum lot size required of 5,000 sq. ft. If the proposal is to be
developed as one project site, a lot combination or lot line adjustment would be required to
remove or reconfigure the existing lot lines.
Building Coverage and Impervious Surface Coverage – The CA zone allows a maximum
building coverage of 65 percent, or 75 percent if parking is provided within a building or within
an on-site parking garage. There is no maximum impervious surface coverage for the zone.
The proposal would result in a total building footprint of 9,850 sq. ft., which results in a lot
coverage of 13 percent on the 72,980 sq. ft. site, which is less than the 65 percent maximum
coverage allowed.
Setbacks – Setbacks are the distance between the building and the property line or any private
access easement. Setback requirements in the CA zone are as follows: 15 feet minimum for
the front yard; a 20-foot maximum front yard setback; 15 feet minimum for the secondary
front yard; a 20-foot maximum secondary front yard; no rear or side yard setbacks unless the
property abuts a residential zoned property, where the setback along residentially zoned
properties is 15 feet. The proposal includes a 15-foot front and secondary front setback for
the proposed bank building, however a 10-foot front setback is proposed for the
convenience store. The proposal shall be revised to provide the required 15-foot front yard
setback for the convenience store.
Building Height – The maximum building height that would be allowed in the CA zone is 50
feet and 60 feet for mixed use structures with a residential component. The submitted
materials did not include building elevations, therefore staff was unable to verify
compliance with the building height requirements for the CA zone.
3. Screening: Screening must be provided for all surface-mounted and roof top utility and
mechanical equipment. The site plan application will need to include elevations and details
for the proposed methods of screening. No mechanical or utility equipment was identified
in the submitted materials. See RMC 4-4-095 for specific requirements.
4. Refuse and Recycling Areas: Refuse and recycling areas need to meet the requirements of
RMC 4-4-090, “Refuse and Recyclables Standards.”
In office, educational and institutional developments, a minimum of two (2) square feet per
every one thousand (1,000) square feet of building gross floor area shall be provided for
recyclables deposit areas and a minimum of four (4) square feet per one thousand (1,000)
square feet of building gross floor area shall be provided for refuse deposit areas. A total
minimum area of one hundred (100) square feet shall be provided for recycling and refuse
deposit areas. The proposed office square footage would total 2,850 sq. ft. and would be
required to provide a total minimum of 100 sq. ft. for refuse and recyclable deposit areas.
Benson & Petrovitsky Redevelopment
Page 3 of 8
July 17, 2022
For retail developments, a minimum of five (5) square feet per every 1,000 square feet of
building gross floor area shall be provided for recyclables deposit areas and a minimum of ten
(10) square feet per 1,000 square feet of building gross floor area shall be provided for refuse
deposit areas. A total minimum area of 100 square feet shall be provided for recycling and
refuse deposit areas. The proposed 4,100 sq. ft. convenience store would be required to
provide a total minimum of 100 sq. ft. of refuse and recycling deposit areas. Compliance
with the refuse and recyclable deposit area standards would be verified during the formal
land use review process.
Outdoor refuse and recyclables deposit areas and collection points shall not be located in any
required setback or landscape areas. A conceptual site plan meeting the requirements of
RMC 4-4-090C.2, shall be submitted with a land use application. Enclosures for outdoor
refuse or recyclables deposit areas/collection points and separate buildings used primarily to
contain a refuse or recyclables deposit area/collection point shall have gate openings at least
twelve feet (12') wide for haulers.
The architectural design of any structure enclosing an outdoor refuse or recyclables deposit
area or any building primarily used to contain a refuse or recyclables deposit area shall be
consistent with the design of the primary structure on the site as determined by the
Development Services Division Director through Site Plan review.
5. Landscaping: All portions of the development area not covered by structures, required
parking, access, circulation or service areas, must be landscaped with native, drought-
resistant vegetative cover. The minimum on-site landscape width required along street
frontages is 10 feet, except where reduced through the site plan development review process.
All surface parking lots shall have perimeter landscaping and interior parking lot landscaping
meeting the standards of RMC 4-4-070.
Surface parking lots with more than fourteen (14) stalls shall be landscaped with plantings
and trees. Interior parking lot landscaping shall be provided as follows:
Total Number of
Parking Stalls
Minimum Landscape
Area
15 to 50 15 sf/parking space
51 to 99 25 sf/parking space
100 or more 35 sf/parking space
Please refer to landscape regulations for additional general and specific landscape
requirements. A conceptual landscape plan and landscape analysis meeting the
requirements in RMC 4-8-120D.12, shall be submitted with a land use application and a
detailed landscape plan and landscape analysis shall be submitted with a building permit
application.
6. Significant Tree Retention: If significant trees (greater than 6-inch caliper or 8-caliper inches
for alders and cottonwoods) are proposed to be removed, a tree inventory, tree retention
plan and worksheet, and arborist report shall be provided with the formal land use application
as defined in RMC 4-8-120. The tree retention plan must show preservation of at least 10% of
significant trees and indicate how proposed building footprints would be sited to
Benson & Petrovitsky Redevelopment
Page 4 of 8
July 17, 2022
accommodate preservation of significant trees that would be retained (RMC 4-4-130H1.a).
When the required number of protected trees cannot be retained, replacement trees, with at
least a two-inch (2") caliper or an evergreen at least six feet (6') tall, shall be planted at a rate
of twelve (12) caliper inches of new trees to replace each protected tree removed. The City is
currently amending its tree retention regulations, the proposal would be subject to the
applicable tree retention regulations in effect at the time of Building Permit submittal.
Administrator may authorize the planting of replacement trees on the site if it can be
demonstrated to the Administrator's satisfaction that an insufficient number of trees can
be retained.
Significant trees shall be retained in the following priority order:
Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees
on slopes greater than 20%; significant trees adjacent to critical areas and their associated
buffers; and significant trees over 60’ in height or greater than 18” caliper.
Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; other
significant native evergreen or deciduous trees; and other significant non-native trees.
Priority Three: Alders and cottonwoods shall be retained when all other trees have been
evaluated for retention and are not able to be retained, unless the alders and/ or
cottonwoods are used as part of an approved enhancement project within a critical area or
its buffer.
The Administrator may require an independent review of any land use application that
involves tree removal and land clearing at the City's discretion. A formal tree retention plan
and arborist report would be required with the land use application.
7. Fences/Retaining Walls: If the applicant intends to install any fences or retaining walls as part
of this project, the location must be designated on the landscape plan or grading plan
respectively. A fence and/or wall detail should also be included on the plan if proposed.
8. Parking: Parking for vehicles, loading areas, and driveways shall be provided in accordance
with the provisions of the current parking regulations of RMC 4-4-080, “Parking, Loading, and
Driveway Regulations.”
The following ratios would be applicable to the site:
Parking Type Area Ratio Required Spaces
Retail 4,100 sf A minimum and maximum of 2.5 per
1,000 square feet of net floor area
Minimum and
maximum of 10
stalls are
required.
Bank 2,850 sf A minimum of 2.5 per 1,000 square
feet of net floor area and a
maximum of 5.0 per 1,000 square
feet of net floor area
Minimum of 7
spaces and a
maximum of 14
spaces are
required
Benson & Petrovitsky Redevelopment
Page 5 of 8
July 17, 2022
Drive-
through
retail or
services
The drive-through facility shall be so
located that sufficient on-site
vehicle stacking space is provided
for the handling of motor vehicles
using such facility during peak
business hours. Typically 5 stacking
spaces per window are required
unless otherwise determined by the
Community and Economic
Development Administrator.
Stacking spaces cannot obstruct
required parking spaces or
ingress/egress within the site or
extend into the public right-of-way.
5 stacking spaces
are required if a
drive-through is
proposed.
The proposal would require a minimum of 17 spaces and a maximum of 24 spaces. The
proposal for 51 spaces exceeds the maximum number of spaces permitted.
If the proposal provides more or less parking than required by code, up to 25 more or 25
percent (25%) less is allowed with justification which may include quantitative information
such as sales receipts, documentation of customer frequency, parking standards of nearby
cities, or a parking analysis. Beyond the 25% allowance, a request for a parking modification
would need to be applied for and granted. This detailed written request can be submitted
before or concurrently with a site plan application.
The applicant will be required at the time of land use permit to provide a parking analysis of
the subject site. The analysis would include dimensions of stalls and drive aisles. See RMC 4-
4-080 for more details:
▪ Parking Space Dimensions: It should be noted that the parking regulations specify
standard stall dimensions of 9 feet x 20 feet, compact dimensions of 8½ feet x 16 feet,
and parallel stall dimensions of 9 feet x 23 feet. ADA accessible stalls must be a minimum
of 8 feet in width by 20 feet in length, with an adjacent access aisle of 8 feet in width for
van accessible spaces. Up to 40 percent of stalls may be compact spaces designated for
employee parking, and up to 30 percent of stalls may be compact spaces if designated for
all users. The appropriate amount of ADA accessible stalls based on the total number of
spaces must be provided.
Bicycle parking shall be provided for all non-residential developments that exceed four
thousand (4,000) gross square feet in size. The number of bicycle parking spaces shall be
equal to ten percent (10%) of the number of required off-street vehicle parking spaces.
9. Access/Driveways: Driveway widths are limited by the driveway standards, in RMC 4-4-080I.
Access is proposed via two curb cuts, one off of Benson Dr. S/108th Ave SE and the other off
of SE Petrovitsky Rd. There shall be no more than one driveway for each one hundred sixty
five feet (165') of street frontage serving any one property or among properties under unified
ownership or control; for each one hundred sixty five feet (165') of additional street frontage
another driveway may be permitted.
Benson & Petrovitsky Redevelopment
Page 6 of 8
July 17, 2022
10. Signs: Signs are required to meet the minimum standards of RMC 4-4-100 “Sign Regulations”
and require sign permit review which is different than building permit review. There are
specific commercial sign regulations in RMC 4-4-100E.5.a “Business Signs – General.”
• Freestanding, Ground, Roof and Projecting Signs: Each individual business
establishment may have only one sign for each street frontage of any one of the
following types: Freestanding, roof, ground, projecting or combination. Each sign shall
not exceed an area greater than one and one-half (1-1/2) square feet for each lineal
foot of property frontage which the business occupies up to a maximum of three
hundred (300) square feet; or if such sign is multi- faced, the maximum allowance
shall not be more than three hundred (300) square feet. However, a maximum of one-
half (1/2) of the allowed square footage is allowed on each face.
• Signs within the Urban Design Area, Maximum Height of Freestanding Signs:
Freestanding ground-related monument signs, with the exception of primary entry
signs, shall be limited to five feet (5') above finished grade, including support
structure.
• Wall Signs: Wall signs are permitted with a total copy area not exceeding twenty
percent (20%) of the building facade to which it is applied.
• Small Parking and Traffic Control Signs: Parking and traffic control signs two (2)
square feet or less on private property are allowed without a sign permit.
11. Lighting: New parking lot and building lighting would require a lighting plan and shall meet
the lighting standards (RMC 4-4-075). A detailed lighting plan and analysis is required as part
of the building permit submittal.
12. Urban Design Regulations: Compliance with Urban Design Regulations, District ‘D’, is
required. The land use application shall provide a written narrative to identify how the
project meets each applicable urban design regulation. Please refer the standards in their
entirety at RMC 4-3-100. The following bullets are some, but not all, of the guidelines and
standards outlined in the regulations.
• A primary entrance of each building shall be located on the façade facing a street,
shall be prominent, visible from the street, connected by a walkway to the public
sidewalk, and include human-scale elements.
• Parking shall be located so that no surface parking is located between a building and
the front property line, or the building and side property line, on the street side of a
corner lot.
• Amenities such as outdoor group seating, benches, transit shelters, fountains, and
public art shall be provided.
• On any façade visible to the public, transparent windows and/or doors are required
to comprise at least 50% of the portion of the ground floor facade that is between 4
feet and 8 feet above ground.
• Buildings shall use at least one of the following elements to create varied and
interesting roof profiles (see illustration, subsection RMC 4-3-100I.5.f): extended
parapets; feature elements projecting above parapets; projected cornices; pitched or
sloped roofs.
Benson & Petrovitsky Redevelopment
Page 7 of 8
July 17, 2022
• Buildings shall employ material variations such as colors, brick or metal banding,
patterns, or textural changes.
• A public plaza is required at the intersection of Benson Dr/108th Ave SW and SE
Petrovitsky/SE 176th St. The plaza shall measure no less than one thousand (1,000)
square feet with a minimum dimension of twenty feet (20') on one side abutting the
sidewalk.
Design review would be completed during the formal land use review process.
13. Critical Areas: Slopes with grades that are less than twenty-five percent (25%) are mapped on
the northeast corner of the project site.
14. Environmental Review: The proposal would be subject to Environmental (SEPA) Review as it
includes the construction of a new commercial buildings cumulatively over 4,000 square feet
in area and parking for more than 20 vehicles. Therefore, an environmental checklist is a
submittal requirement. An environmental determination will be made by the Renton
Environmental Review Committee.
15. Site Plan Approval: Per RMC 4-9-200, site plan review is required for any development in the
CA zone. The purpose of the site plan review process is to analyze the detailed arrangement
of project elements to mitigate negative impacts where necessary to ensure project
compatibility with the physical characteristics of a site and with the surrounding area. Site
plan review ensures quality development consistent with City goals and policies. Site plan
review analyzes elements including, but not limited to, site layout, building orientation and
design, pedestrian and vehicular environment, landscaping, natural features of the site,
screening and buffering, parking and loading facilities, and illumination to ensure
compatibility with potential future development. Decisional criteria for site plan approval are
itemized in RMC 4-9-200.E.3.
16. Permit Requirements: The proposed project would require Hearing Examiner Site Plan
Review and Environmental (SEPA) Review. All land use permits would be processed within an
estimated time frame of 12 weeks. The application fees would total $5,670 ($3,800 Site Plan
Review + $1,600 SEPA Review + $270 technology fee), all fees are subject to change. Any
modifications requested would require an additional $260 fee. Detailed information
regarding the land use application submittal is provided in the attached handouts. In addition
to the required land use permits, separate construction and building permits would be
required. Detailed information regarding the land use application submittal can be found on
the City’s website by clicking “City Documents” on the home screen, then “CED Forms”. All
forms are in alphabetical order. The City now requires electronic plan submittal for all
applications. The City’s Electronic File Standards can also be found on the City’s website.
17. Public Information Sign: Public Information Signs are required for all Type II and Type III Land
Use Permits as classified by RMC 4-8-080. Public Information Signs are intended to inform the
public of potential land development, specific permits/actions being considered by the City,
and to facilitate timely and effective public participation in the review process. The applicant
must follow the specifications provided in the public information sign handout. The applicant
is solely responsible for the construction, installation, maintenance, removal, and any costs
associated with the sign.
18. Public Meeting: Please note a neighborhood meeting, according to RMC 4-8-090, is required
for:
Benson & Petrovitsky Redevelopment
Page 8 of 8
July 17, 2022
a. Preliminary plat applications;
b. Planned urban development applications; and
c. Projects estimated by the City to have a monetary value equal to or greater than ten
million dollars ($10,000,000), unless waived by the Administrator.
The intent of this meeting is to facilitate an informal discussion between the project developer
and the neighbors regarding the project. The neighborhood meeting occurs after a pre-
application meeting and before submittal of applicable permit applications. The public
meeting shall be held within Renton city limits, at a location no further than two (2) miles
from the project site.
19. Public Outreach Sign: Planned urban development projects require the applicant to install a
public outreach sign. Public outreach signs are intended to supplement information provided
by public information signs by allowing an applicant to develop a personalized promotional
message for the proposed development. The sign is also intended to provide the public with
a better sense of proposed development by displaying a colored rendering of the project and
other required or discretionary information that lends greater understanding of the project.
20. Impact Fees: In addition to the applicable building and construction fees, impact fees would
be required. Fees change periodically and the fees in effect at the time of building permit
issuance would apply. For informational purposes, the 2022 impact fees are as follows:
• A Fire impact fee currently assessed at $1.25 per sf for retail and $0.26 per sf of
commercial office space;
• A transportation impact fee assessed based on the rate in effect in the ITE manual;
A handout listing all of the City’s Development related fees is available for your review at
https://edocs.rentonwa.gov/Documents/Browse.aspx?id=8217302&dbid=0&repo=CityofRe
nton
Next Steps: When the formal application materials are complete, the applicant shall have the
materials pre-screened prior to submitting the complete application package. Please contact
Jill Ding, Senior Planner at 425-430-6598 or jding@rentonwa.gov to submit prescreen
materials and subsequent land use application.
Expiration: Once the Site Plan Review has been approved, the applicant has two (2) years to
comply with all conditions of approval and to apply for any necessary building and civil
construction permits before the approval becomes null and void. A single two-year extension
may be granted. It is the applicant’s responsibility to monitor the expiration dates.