Loading...
HomeMy WebLinkAboutMFP21005290.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP21005290 IVR Number: 21005290 Permit Information Permit Name: ExteNet Systems - Fiber - EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - OAKESDALEAddress/Location:11/01/2021Application Date:3623049112Parcel Number: 1001 SW 41ST ST Permit Type:11/22/2021Issue Date:Franchise Permit Work Class:11/22/2022Expiration Date:Minor Utility Job Number: SEG 10 - OAKESDALEFranchise Type:Telephone Description: ExteNet Systems Inc. master franchise agreement, ORD 6013 EXTENET SOUTH RENTON PHASE 2 SEG 10 OAKESDALE EXISTING CTL/LUMEN 4" CONDUIT ON THE EAST SIDE OF OAKESDALE AVE SW, FROM THE NORTH EAST CORNER OF SW 43RD ST AND OAKESDALE AVE SW, NORTH. PULL (3) 1.25" INNER DUCTS WITH (1)144F CABLE THROUGH. Contacts Name Address PhoneTypeBilling Michael Smith North Sky Communications 21320 84th Ave S Kent, WA 98032 Applicant Rachel Fenton Extenet Systems LLC 3030 Warrenville Road Warrenville Rd, Suite 340 Lisle, IL 60532 Applicant MGC Permits MGC Technical 6244 185th AVE NE, STE 250 REDMOND, WA 98052 ApplicantX Michael Smith Dycom Industries dba North Sky 11818 SE Mill Plain Blvd, SUITE 410 Vancouver, WA 98684 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 ADVENTURE 2000 LLC 1000 SW 43RD ST RENTON , WA 98057 Owner General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES MFP21005290 Monday - Friday 8:00AM - 3:00PM Scott Warlick CED 11/22/2021 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 10NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1001 SE 41ST ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - DIG AND REPAIR - TCPS-10.19.21.dwgPERMIT NUMBER: RONLYCONFIDENTIAL/PROPRIETARYSHEET: OF 12Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE WITH PEDESTRIAN ESCORT (FOR URBAN ARTERIAL ROADWAY)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYTRAFFIC CONTROL PLAN #1 - USE SET-UP WHERE APPLICABLE ALONG OAKESDALE AVE SW (NORTH BOUND LANE)FLAGGER / SPOTTER STATION -FOR VEHICULAR AND PEDESTRIANTRAFFIC CONTROLOAKESDALE AVE SWSW 43RD ST WORKVEHICLE50'-100'W20-1W20-1W20-5RW4-2RXXXLSPOTTER FLAGGERS ON SITE TO ESCORTPEDESTRIANS THROUGH WORK ZONE1200 SW 43RD STPARCEL NO.36230491081001 SE 41ST STPARCEL NO.362304911218020 80TH AVE SPARCEL NO.3623049096W20-5RW20-1X W20-5RW20-1X WORK AREA100 SQ FTCONTRACTOR TO USE TEMP. ADA RAMPS /HARD SURFACES AS NECESSARY TOMAINTAIN A 5'MIN PED ESCORT PATH.MFP21005290 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 10NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1001 SE 41ST ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - DIG AND REPAIR - TCPS-10.19.21.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 22Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTSIGN LEGEND NORTH SKY COMMUNICATIONS, LLCCONTACT: MICHAEL SMITH22517 88TH AVE SKENT, WA 98031C. 206.305.5881MSMITH@NORTHSKYCOMM.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE WITH PEDESTRIAN ESCORT (FOR URBAN STREET)SCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULTAND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYTRAFFIC CONTROL PLAN #2 - USE SET-UP WHERE APPLICABLE ALONG SW 41ST ST (EAST BOUND LANE)FLAGGER / SPOTTER STATION -FOR VEHICULAR AND PEDESTRIANTRAFFIC CONTROLWORKVEHICLE1001 SE 41ST STPARCEL NO.36230491124001OAKESDALES AVE SWPARCEL NO.3623049032616 SW 41ST STPARCEL NO.3623049001SW 41ST STOAKESDALE AVE SW WORK AREA100 SQ FTW20-1W20-150'-100'SPOTTER FLAGGERS ON SITE TO ESCORTPEDESTRIANS THROUGH WORK ZONEW20-5RW20-1X W20-5RW20-1X CONTRACTOR TO USE TEMP. ADA RAMPS /HARD SURFACES AS NECESSARY TOMAINTAIN A 5'MIN PED ESCORT PATH.W16-7LMFP21005290 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 10NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1001 SE 41ST STRENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RSITE LOCATIONSHEET INDEXSCOPE OF WORK:EXISTING CTL/LUMEN 4" CONDUIT ON THEEAST SIDE OF OAKESDALE AVE SW, FROMTHE NORTH EAST CORNER OF SW 43RD STAND OAKESDALE AVE SW, NORTH. PULL (3)1.25" INNER DUCTS WITH (1)144F CABLETHROUGH.Know what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 17ADDRESS: 1001 SE 41ST ST, RENTON, WA 98057PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - OAKESDALE - PLANS1. COVER SHEET / SITE LOCATION2. LEGEND3. GENERAL NOTES4-5. DESIGN VIEWS A-C6. UNDERGROUND DETAILS7. SITE PHOTOSCONTACTSMATT FRASERMGC TECHNICAL CONSULTING, INC.6244 185TH AVE NEREDMOND, WA 98052C.206.618.5254MATT@MGCTECHNICAL.COMNORTH SKY COMMUNICATIONS, LLCMICHAEL SMITH22517 88TH AVE SKENT, WA 98031C.206.305.5881MSMITH@NORTHSKY.COMSHEET 4SHEET 5SHEET 6MFP21005290 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 10NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1001 SE 41ST ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 27#F#F#F##LEGENDMFP21005290 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 10NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1001 SE 41ST ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RGENERAL NOTESKnow what'sbelow.before you dig.CallRGENERAL NOTES:UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTINGAND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTINGTHE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES. THEDISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED.TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURING CONSTRUCTION, TO ASSURE THAT THE WORK ISFOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALLOTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THECONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY.SPECIFICALLY STATED OTHERWISE.CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCHALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE CITY OF RENTON ENGINEERINGALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS, EARTHCONFIDENTIAL/PROPRIETARYSHEET: OF 37The locations of utilities shown on these drawing are only approximate. MGC TECHNICAL CONSULTING, INC. hereby disclaims any responsibilityto third parties for the accuracy of this information. Persons working in the area covered by this drawing must contact the statewideCall-Before-You-Dig System to ascertain the location of underground utilities prior to performing any excavation.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEED SITE WORKSTANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE CITY OF RENTON REGULATIONS AND APPLICABLE STATEAND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLESTANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIREINSPECTED AND APPROVED BY THE CITY OF RENTON INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TOBE PROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES, AS SHOWN ONTHESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THEFIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCALUTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTSUTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.CONTRACTOR SHALL NOTIFY THE CITY OF RENTON INSPECTOR AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTHTHE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE CITY OF RENTON AND ALL UTILITY COMPANIES WITH REGARDACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLETHE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDSTIMES.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO: EXCAVATION,TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HIS SUBCONTRACTORS, ORALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESSFOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE CITY OF RENTON, THE CONTRACTOR SHALL SUBMIT ATRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIESWITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFICCONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BEHELD WITH CITY OF RENTON.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THEINTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVEDOR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALLCONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT ATTHE CONSTRUCTION SITE AND AVAILABLE TO THE CITY OF RENTON INSPECTOR AT ALL TIMES.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATIONALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TOTIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING.DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THETIME PERIOD APPROVED BY THE CITY OF RENTON.1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16.MFP21005290 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 10NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1001 SE 41ST ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 47DESIGN VIEW A Know what'sbelow.before you dig.CallROAKESDALE AVE SW1200 SW 43RD STPARCEL NO.36230491081001 SE 41ST STPARCEL NO.362304911291' 27'30' 11' 11' 11' 11' 11'CONSTRUCTION NOTES2SW 43RD ST92'28'28'22'11'11'11'MH 3881EXISTING CTL/LUMEN VAULT. ACCESS VAULT TO PULL (1)144F CABLE THROUGH. CONTRACTOR TO VERIFY CORRECTVAULT PRIOR TO WORK.2EXISTING CTL/LUMEN 4" CONDUIT. PULL (3) 1.25"INNERDUCTS WITH (1) 144F CABLE THROUGH. CONTRACTORTO VERIFY CORRECT CONDUIT PRIOR TO WORK.MATCH TO SHEET 517'221'#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #7 FOR SITE PHOTOGRAPHS.211MATCH TOEXTENET SOUTHRENTON - PHASE 2 -SEG 10 S-007393P-023580 - CTL PLANS MFP21005290 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 10NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1001 SE 41ST ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 57DESIGN VIEW B Know what'sbelow.before you dig.CallROAKESDALE AVE SW1001 SE 41ST STPARCEL NO.3623049112PARCEL NO.3623049109SW 43RD ST91'27'30'19'11'11'13'CONSTRUCTION NOTES2EXISTING CTL/LUMEN 4" CONDUIT. PULL (3) 1.25"INNERDUCTS WITH (1) 144F CABLE THROUGH. CONTRACTORTO VERIFY CORRECT CONDUIT PRIOR TO WORK.MATCH TO SHEET 6 MATCH TO SHEET 4371'26' 37' 5'MFP21005290 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 10NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1001 SE 41ST ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: OF 67DESIGN VIEW C Know what'sbelow.before you dig.CallROAKESDALE AVE SW1001 SE 41ST STPARCEL NO.36230491124001OAKESDALES AVE SWPARCEL NO.3623049032SW 41ST ST 91'27'30'11'11'11'12'11'CONSTRUCTION NOTES1EXISTING CTL/LUMEN VAULT. ACCESS VAULT TO PULL (1)144F CABLE THROUGH. CONTRACTOR TO VERIFY CORRECTVAULT PRIOR TO WORK.2EXISTING CTL/LUMEN 4" CONDUIT. PULL (3) 1.25"INNERDUCTS WITH (1) 144F CABLE THROUGH. CONTRACTORTO VERIFY CORRECT CONDUIT PRIOR TO WORK.21281'MATCH TO SHEET 5 MATCH TOEXTENET SOUTHRENTON - PHASE 2 -SEG 10 S-007393P-023580 - CTL PLANSMH 387MFP21005290 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 10NORTH SKY COMMUNICATIONS ENGINEER: MICHAEL SMITHENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1001 SE 41ST ST RENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RSITE PHOTOGRAPHSCONSTRUCTION NOTESKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 771EXISTING CTL/LUMEN VAULT. ACCESS VAULT TO PULL (1)144F CABLE THROUGH. CONTRACTOR TO VERIFY CORRECTVAULT PRIOR TO WORK.2EXISTING CTL/LUMEN 4" CONDUIT. PULL (3) 1.25"INNERDUCTS WITH (1) 144F CABLE THROUGH. CONTRACTORTO VERIFY CORRECT CONDUIT PRIOR TO WORK.PHOTO #1: FACING NORTH ON EAST SIDE OF OAKESDALE AVE SWPHOTO #2: FACING SOUTH ON EAST SIDE OF OAKESDALE AVE SW21MFP21005290 NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 10EXTENET MANAGER: ROBERT HAMMONDENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1001 SE 41ST STRENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - DIG AND REPAIR - TCPS.dwgPERMIT NUMBER: RSIGN LEGENDEXTENET CONTACT: ROBERT HAMMOND3030 WARRENVILLE RD.LISLE, IL 60532C.206.200.8007ROBERT.HAMMOND@EXTENETSYSTEMS.COMROADWORKAHEADRIGHTLANECLOSEDAHEADLEGENDHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESSHORT-TERM STATIONARY WORK ZONE - LANE CLOSURE WITH PEDESTRIAN ESCORT (FOR URBAN ARTERIAL ROADWAY)SCOPE OF WORK:USE WORK AREA TO DIG & REPAIR CONDUIT,AND PULL FIBER CABLE THROUGHSTREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYTRAFFIC CONTROL PLAN #2 - USE SET-UP WHERE APPLICABLE ALONG OAKESDALE AVE SW (NORTH BOUND LANE)FLAGGER / SPOTTER STATION -FOR VEHICULAR AND PEDESTRIANTRAFFIC CONTROLWORKVEHICLECONFIDENTIAL/PROPRIETARYSHEET: 1 OF 1Know what'sbelow.before you dig.CallRJURISDICTION TCP REQUIREMENTS1. SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2. PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3. NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4. MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5. MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6. MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7. MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8. FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9. IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10. ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11. CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13. STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14. LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15. "NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16. CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17. PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18. CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS 100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)* ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.** ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25 30 35 40 45 50 55 60 65 70MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155 200 250 305 360 425 -MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)- - -ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTW20-1W20-5RW4-2RXXXW20-150'-100'LWORK AREA420 SQ FTOAKESDALE AVE SWSW 43RD STSW 41ST ST1001 SE 41ST STPARCEL NO.3623049112PARCEL NO.3623049109SPOTTER FLAGGERS ON SITE TO ESCORTPEDESTRIANS THROUGH WORK ZONE NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 10EXTENET MANAGER: ROBERT HAMMONDENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1001 SE 41ST STRENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RSITE LOCATIONSCOPE OF WORK:DIG AND REPAIR EXISTING CTL/LUMEN 4" CONDUIT ON THE EAST SIDE OF OAKESDALE AVE SW. PULL (3) 1.25" INNERDUCTS WITH (1) 144F CABLE THROUGH.Know what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: 1 OF 5ADDRESS: 1001 SE 41ST ST, RENTON, WA 98057PROJECT NAME: EXTENET - SOUTH RENTON - PHASE 2 - SEG 10 - DIG AND REPAIR - PLANS1.COVER SHEET / SITE LOCATION2.LEGEND3.GENERAL NOTES4.DESIGN VIEWS A5.. UNDERGROUND DETAILSCONTACTSROBERT HAMMOND3030 WARRENVILLE RD.LISLE, IL 60532C.206.200.8007ROBERT.HAMMOND@EXTENETSYSTEMS.COMMATT FRASERMGC TECHNICAL CONSULTING, INC.15365 NE 90TH ST REDMOND, WA 98052C.206.618.5254MATT@MGCTECHNICAL.COMSHEET INDEXSHEET 4EXTENET MANAGER: NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 10EXTENET MANAGER: ROBERT HAMMONDENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1001 SE 41ST STRENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: 2 OF 5#F#F#F##LEGEND NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 10EXTENET MANAGER: ROBERT HAMMONDENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1001 SE 41ST STRENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RGENERAL NOTESKnow what'sbelow.before you dig.CallRGENERAL NOTES:UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTINGAND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTINGTHE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES. THEDISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED.TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURING CONSTRUCTION, TO ASSURE THAT THE WORK ISFOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALLOTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THECONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY.SPECIFICALLY STATED OTHERWISE.CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCHALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE CITY OF RENTON ENGINEERINGALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS, EARTHCONFIDENTIAL/PROPRIETARYSHEET: 3 OF 5The locations of utilities shown on these drawing are only approximate. MGC TECHNICAL CONSULTING, INC. hereby disclaims any responsibilityto third parties for the accuracy of this information. Persons working in the area covered by this drawing must contact the statewideCall-Before-You-Dig System to ascertain the location of underground utilities prior to performing any excavation.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEED SITE WORKSTANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE CITY OF RENTON REGULATIONS AND APPLICABLE STATEAND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLESTANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIREINSPECTED AND APPROVED BY THE CITY OF RENTON INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TOBE PROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES, AS SHOWN ONTHESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THEFIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCALUTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTSUTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.CONTRACTOR SHALL NOTIFY THE CITY OF RENTON INSPECTOR AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTHTHE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE CITY OF RENTON AND ALL UTILITY COMPANIES WITH REGARDACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLETHE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDSTIMES.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO: EXCAVATION,TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HIS SUBCONTRACTORS, ORALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESSFOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE CITY OF RENTON, THE CONTRACTOR SHALL SUBMIT ATRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIESWITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFICCONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BEHELD WITH CITY OF RENTON.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THEINTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVEDOR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALLCONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT ATTHE CONSTRUCTION SITE AND AVAILABLE TO THE CITY OF RENTON INSPECTOR AT ALL TIMES.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATIONALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TOTIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING.DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THETIME PERIOD APPROVED BY THE CITY OF RENTON.1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16. NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 10EXTENET MANAGER: ROBERT HAMMONDENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1001 SE 41ST STRENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: 4 OF 5DESIGN VIEW AKnow what'sbelow.before you dig.CallROAKESDALE AVE SW1001 SE 41ST STPARCEL NO.3623049112PARCEL NO.3623049109SW 43RD ST91'27'30'19'11'11'13'CONSTRUCTION NOTES2EXISTING CTL/LUMEN 4" CONDUIT. PULL (3) 1.25"INNERDUCTS WITH (1) 144F CABLE THROUGH. CONTRACTORTO VERIFY CORRECT CONDUIT PRIOR TO WORK.2MATCH TO EXTENET SOUTH RENTON PHASE 2 -SEG 10 S-007393 P-023580 - CTL PLANS MATCH TO EXTENET SOUTH RENTON PHASE 2 -SEG 10 S-007393P-023580 - CTL PLANS 3PROPOSED DIG AND REPAIR EXISTING CTL/LUMEN 4"CONDUIT. PULL (3) 1.25" INNERDUCTS WITH (1) 144F CABLETHROUGH. CONTRACTOR TO VERIFY CORRECT CONDUITPRIOR TO WORK.241'3AGRESTORATION NOTESARESTORE LANDSCAPE PER CITY OF RENTONSTANDARDS.GRESTORE SIDEWALK PANEL PER CITY OFRENTON STANDARDS.6' 37' 5' NO.123PROJECT NAME: EXTENET SOUTH RENTON - PHASE 2 - SEG 10EXTENET MANAGER: ROBERT HAMMONDENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 1001 SE 41ST STRENTON, WA 98057DRAWING NAME: NORTHSKY - EXTENET SOUTH RENTON - PHASE 2 - SEG 10 - DIG AND REPAIR - PLANS.dwgPERMIT NUMBER: RCONFIDENTIAL/PROPRIETARYSHEET: 5 OF 5Know what'sbelow.before you dig.CallRTYPICAL TRENCH IN SOIL DETAILSCALE: NTSEXISTING GROUNDWARNING TAPEBACKFILL(8" LAYERS)6" MIN.12"36" MIN. DEPTH4"BACKFILL(COMPACTED @ 90%)HDPE DUCTCLEAN BACKFILLBACKFILL(COMPACTED EARTH @ 90%)6" MNRL AGG TYPE 2(COMPACTED AS SPECIFIEDIN CONTRACT DOCUMENTS)TYPICAL CONCRETE SIDEWALK PANEL CROSS SECTION DETAILSCALE: NTSNEW PANEL-MATCH EXISTINGEXPAND TO JOINTMATCH EXISTING24"12"6"6"6" MIN. TYPE 2 CRUSHEDROCKCOMPACTED BACKFILL6" SAND COVER6" SAND BEDDING