HomeMy WebLinkAboutWater Revision 1.pdfJ J UP UP 1'-2"5'-3 3/8"172'-2 1/8"54'-11 7/ 8" 4'-0"313232 3232323233 33CB# 9 CB# 10 CB# 13 CB# 12 CB# 14 CB# 8 CB# 7 TD #3 FC# 2 WQ# 1 CB #7B P - (4) SP 10 SP 3 SP 5 SP 8 SP 6 SP 7 SP 9 SP 2 SP 1 TD #1 CB# 11 PROPOSED MULTIFAMILY BUILDING FFE=32.12 FC# 4 WQ# 2 30INLET EL: 31.50 INLET EL: 31.65 5+13 0+00 1+ 002+003+004+00 5+00BP: 0+00.00EP: 5+13.46 PI: 0+10.66PI: 1 + 2 2. 0 0 PI: 2+5 2. 7 1 PI: 3+04.80 PI: 4+54.71PI: 4+93.86 SP 11 SP 4 FC# 1 FC# 3 CONNECT TO BUILDING PLUMBING. SEE MECHANICAL FOR CONTINUATION. IE: 26.56 8" (SW) CONNECT TO BUILDING PLUMBING. SEE MECHANICAL FOR CONTINUATION. IE: 28.76 8" (N) RIM: 32.39 RIM: 32.41 RIM: 32.37 32 33STORM PROFILE START STORM PROFILE END FRENCH DRAIN IE: 29.00 210 LF FRENCH DRAIN CB #7A SP 3AFC #1A TD #2 CONNECT TO BUILDING PLUMBING. TO COMBINE WITH PARKING DRAINAGE TO OIL WATER SEPARATOR. SP 12 TD #4 31CB #7A CB #7B CB# 7 CB# 8 CB# 9 CB# 10 CB# 11 TYPE 1 RIM= 31.57 IE= 26.91 (8" CPEP, SW) 48" TYPE 2 RIM= 30.90 IE= 26.10 (24" CPEP, E) IE= 26.10 (12" CPEP, NE) 54" TYPE 2 CONTROL STRUCTURE RIM= 31.69 IE= 28.71 (6" DI, E) IE= 26.19 (12" CPEP, SW) IE= 25.69 (36" CMP, NW) 54" TYPE 2 RIM= 33.18 IE= 25.69 (36" CMP, SE) IE= 25.69 (36" CMP, NW) 54" TYPE 2 RIM= 32.29 IE= 25.69 (36" CMP, SE) IE= 25.69 (36" CMP, N) 72" TYPE 2 RIM= 31.82 IE= 25.69 (36" CMP, S) IE= 25.69 (36" CMP, E) 54" TYPE 2 RIM= 32.53 IE= 27.92 (8" DI, S) IE= 25.69 (36" CMP, W) CB# 12 CB# 13 CB# 14 TD #1 TD #2 TD #3 TD #4 TYPE 1 RIM= 31.11 IE= 28.01 (8" CPEP, E) TYPE 1 RIM= 31.66 IE= 27.01 (8" CPEP, S) IE= 27.01 (8" CPEP, W) TYPE 1 RIM= 32.24 IE= 28.37 (8" DI, N) IE= 28.37 (8" CPEP, S) SOUTH TRENCH DRAIN SIDE OUTLET RIM= 30.24 IE= 29.37 (8" DI, W) TRENCH DRAIN NORTH END IE TRENCH DRAIN:29.80 RIM= 30.32 TRENCH DRAIN WEST END BOTTOM OUTLET CONNECTION TRENCH EL:30.78 RIM= 31.39 IE= 29.78 (6" DI, W) TRENCH DRAIN EAST END IE TRENCH DRAIN:30.99 RIM= 31.51 # #STORM CONNECTIONS FC #1A FC# 1 FC# 2 FC# 3 FC# 4 WQ# 1 WQ# 2 IE= 26.86 (8" CPEP, NE) IE= 26.19 (8" CPEP, NE) IE= 26.86 (8" CPEP, NE) IE= 26.86 (8" CPEP, N) IE= 26.86 (8" CPEP, S) IE= 28.65 (8" CPEP, SW) IE= 28.51 (8" CPEP, N) SP 1 SP 2 SP 3 SP 3A SP 4 SP 5 SP 6 SP 7 SP 8 SP 9 SP 10 SP 11 SP 12 63 LF 24" CPEP @ 0.40% 9 LF 12" CPEP @ 1.00% 11 LF 6" DI @ 10.00% 2 LF 8" CPEP @ 2.00% 37 LF 8" CPEP @ 1.00% 14 LF 8" CPEP @ 13.01% 26 LF 8" CPEP @ 3.84% 8 LF 8" CPEP @ 2.00% 38 LF 8" CPEP @ 4.29% 39 LF 8" DI @ 1.14% 86 LF 8" DI @ 1.12% 20 LF 8" CPEP @ 2.00% 20 LF 8" DI @ 1.00% CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-4200WATERSHED APARTMENTS CIVIL CONSTRUCTION PERMITWATERSHED APARTMENTSbelow.Know what'sCallbefore you dig. R Civil Engineers Structural Engineers Landscape Architects Community Planners Land Surveyors Neighbors T A C O M A 2215 North 30th Street, Suite 300, Tacoma, WA 98403253.383.2422TEL S E A T T L E 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101206.267.2425TEL C21005115 LUA21-000239PR21-000258WATERSHED APARTMENTSSTORM DRAINAGE MANHOLE - TYPE 2 CATCH BASIN - TYPE I STORM DRAINAGE CLEANOUT DOWNSPOUT CONNECTION ACCESS RISER STORM DRAINAGE PIPING ROOF DRAIN PIPING FOOTING DRAIN FRENCH DRAIN TRENCH DRAIN DS GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 N 440 LF 3-FOOT DIAMETER CMP DETENTION TANK BOTTOM EL=25.69 DESIGN SURFACE ELEVATION=28.19 VOLUME AT RISER=2,626 CF WQ #1 BIOPOD SURFACE WATER QUALITY SYSTEM, WITH CURB INLET. WQ #2 BIOPOD SURFACE WATER QUALITY SYSTEM, WITH CURB INLET. PROPOSED SEWER, GAS, AND WATER PER UTILITY PLAN, SHEET C6.00. 1 2 3 # #STORM PIPE TABLE # #STORM STRUCTURE TABLE 2 1 3 3 3 PROPOSED CIP WALL WITH GUARDRAIL KEY NOTES LEGEND 3 3 1.BARE GALVANIZED METAL SHALL NOT BE USED FOR MATERIALS THAT COVEY STORMWATER, SUCH AS ROOFS, CANOPIES, SIDING, GUTTERS, DOWNSPOUTS, ROOF DRAINS AND PIPES. ANY GALVANIZED MATERIALS SHALL HAVE AN INERT, NON-LEACHALBE FINISH, SUCH AS BAKED ENAMEL, FLUOROCARBON PAINT (SUCH AS KYNAR OR HYLAR), FACTORY-APPLIED EPOXY, PURE ALUMINUM, OR ASPHALT COATING. ACRYLIC PAINT, POLYESTER PAINT, FIELD-APPLIED, AND PART ZINC (SUCH AS GALVALUME) COATINGS ARE NOT ACCEPTABLE. 2.BURIED UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION. PRIOR TO INSTALLATION OF ANY PROJECT IMPROVEMENTS, CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF EXISTING UTILITIES. IN THE EVEN T OF ANY DISCREPANCY FROM THE INFORMATION PRESENTED ON THESE PLANS, CONTRACTOR SHALL NOTIFY THE DESIGN ENGINEER. 3.CONSTRUCT ALL UTILITIES IN CONFORMANCE WITH THE STORM AND ROOF DRAIN TRENCH SECTION DETAIL UNLESS NOTED OTHERWISE. 4.REFER TO ARCHITECTURAL DRAWINGS FOR EXACT QUANTITY AND LOCATION OF DOWNSPOUTS. 5.REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF RAIN LEADERS. 6.ALL STORM PIPES CONNECTING TO CONCRETE STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT. 7.ROOF AND FOOTING DRAIN TIGHT LINES ARE LOCATED ON DRAWINGS FOR CLARITY AND ARE TO BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES. ALL STORM DRAINAGE AND ROOF DRAIN LINE CLEANOUTS SHALL COMPLY WITH THE CLEANOUT DETAIL. 8.ALL CATCH BASINS ARE TO BE SITUATED SUCH THAT THE OUTSIDE EDGE OF THE FRAME IS AT THE FACE OF CURB OR FLOW LINE OF GUTTER (WHERE APPLICABLE). 9.ALL STORM DRAINAGE PIPE SHALL BE CPEP UNLESS NOTED OTHERWISE. 10.ALL ROOF DRAINS SHALL BE 8"Ø WITH A MINIMUM SLOPE OF 1.00% AND MINIMUM COVER OF 3' UNLESS NOTED OTHERWISE. PIPE MATERIAL SHALL BE PVC SDR35 UNLESS NOTED OTHERWISE. 11.ALL TYPE 2 CATCH BASINS SHALL HAVE AN INSIDE DIAMETER OF 48" UNLESS NOTED OTHERWISE. 12.ALL STRUCTURE GRATES SHALL BE LOCKING AND SHALL CONFORM TO THE FOLLOWING UNLESS NOTED OTHERWISE: 12.1.VANED - WSDOT STANDARD PLAN B-30.30-01 FOR STRUCTURES IN THE STREET OR PARKING AREAS. 12.2.ADA - TWS OLYMPIC FOUNDARY FOR ALL LAWN AND PEDESTRIAN AREAS. 12.3.SOLID - WSDOT STANDARD PLANS B-30.20-02 AND B-30.70-03 WHERE NOTED 12.4.BEEHIVE -OLYMPIC FOUNDRY PART NO. SM60BH OR APPROVED EQUIVALENT WHERE NOTED. STORM DRAINAGE NOTES: 1 C5.10 1 C5.10 1 C5.10 4 C5.10 2 C5.20 1 C5.20 1 C5.30 3 C5.20 4 C5.20 2 C5.10 FOR CITY OF RENTON STANDARD NOTES SEE SHEET C5.40. 5 C5.20 IE= 27.18 (6" PERF, E) DRAINAGE CONTROL PLAN 2 C5.30 R-420013 07/26/2022 DEVELOPMENT ENGINEERING JChavez 07/27/2022 20 25 30 35 20 25 30 35 FG 31.730+50FG 32.06FG 32.601+00FG 33.18FG 33.151+50FG 32.84FG 32.542+00FG 32.18FG 31.962+50FG 32.27FG 32.393+00FG 32.04FG 32.833+50FG 32.71FG 32.254+00FG 32.01FG 32.104+50FG 32.46FG 32.385+00FG 32.303.04' 3.18'3.21' 3.25' 2.00' LIVE STORAGE 0.50' DEAD STORAGE 0.50' FREEBOARD PROPOSED GRADE AT STORM CENTERLINE EXISTING GRADE AT STORM CENTERLINE EXISTING GRADE AT STORM CENTER PROPOSED GRADE AT STORM CENTER PROPOSED WATER MAIN 1.57' DESIGN WATER SURFACE EL: 28.19 CB# 7 FLOW CONTROL STRUCTURE CB# 8 CB# 9 CB# 10 CB# 11 CB# 14 BOTTOM OF 3-FOOT TANK: 25.69 FC# 1 FC# 2 FC# 3 FC# 4 111 LF 36" CMP 131 LF 36" CMP 150 LF 36" CMP 52 LF 36" CMP CONNECT TO BUILDING PLUMBING FC# 1A CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-4200WATERSHED APARTMENTS CIVIL CONSTRUCTION PERMITWATERSHED APARTMENTSbelow.Know what'sCallbefore you dig. R Civil Engineers Structural Engineers Landscape Architects Community Planners Land Surveyors Neighbors T A C O M A 2215 North 30th Street, Suite 300, Tacoma, WA 98403253.383.2422TEL S E A T T L E 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101206.267.2425TEL C21005115 LUA21-000239PR21-000258WATERSHED APARTMENTS8" OUTLET2' MIN. CLEARANCE TO ANY PORTION OF VERTICAL RISER, ELBOWS, OR SHEAR GATE 36"COVER6"MIN.36"Ø CMP STANDARD MANHOLE STEPS @ 12" O.C. (TYP.) SEE DRAINAGE CONTROL PLAN FOR RIM ELEVATIONS STANDARD LOCKING MH. FRAME & LID 36" INLET8" INLET DETENTION TANK DETENTION TANK NOTES: 1. USE ADJUSTING BLOCKS AS REQUIRED TO BRING FRAME TO GRADE. 2. ALL MATERIALS TO BE ALUMINUM OR GALVANIZED AND ASPHALT COATED (TREATMENT 1 OR BETTER). 3. MUST BE LOCATED FOR ACCESS BY MAINTENANCE VEHICLES. 4. THE MAXIMUM DEPTH FROM FINISHED GRADE TO TANK INVERT SHALL BE 20 FEET. 5. ACCESS OPENINGS SHALL BE POSITIONED A MAXIMUM OF 50 FEET FROM ANY LOCATION WITHIN THE TANK. 6. ALL TANK ACCESS OPENINGS SHALL HAVE ROUND, SOLID LOCKING LIDS WITH 5/8 INCH DIAMETER ALLEN HEAD CAP SCREWS. 7. THIRTY-SIX INCH MINIMUM DIAMETER CMP RISER-TYPE MANHOLES OF THE SAME GAGE AS THE TANK MATERIAL MAY BE USED FOR ACCESS ALONG THE LENGTH OF THE TANK. 8. THE TOP SLAB IS SEPARATED (1 INCH MINIMUM GAP) FROM THE TOP OF THE RISER TO ALLOW FOR DEFLECTIONS FROM VEHICLE LOADINGS WITHOUT DAMAGING TANK. 9. ALL TANK ACCESS OPENINGS MUST BE READILY ACCESSIBLE BY MAINTENANCE VEHICLES. 10. TANKS MUST COMPLY WITH THE OSHA CONFINED SPACE REQUIREMENTS, WHICH INCLUDES CLEARLY MARKING ENTRANCES TO CONFINED SPACE AREAS. THIS MAY BE ACCOMPLISHED BY HANGING A REMOVABLE SIGN IN THE ACCESS RISER(S), JUST UNDER THE ACCESS LID. 24"MAX. 36" 6" PLAN VIEW STANDARD 60" CONCRETE TOP SLAB STANDARD LOCKING MH. FRAME & COVER 36" CMP RISER STANDARD 60" CONCRETE TOP SLAB COMPACTED PIPE BEDDING (TYP) WELD OR BOLT STANDARD MH. STEPS 12" O.C. FRAME LOCKING LID (MARKED "DRAIN") MOUNTED OVER 24" DIA. ECCENTRIC OPENING MAINTAIN 1" GAP BETWEEN BOTTOM OF SLAB & TOP OF RISER - PROVIDE PLIABLE GASKET TO EXCLUDE DIRT RISER, 36" DIA. MIN., SAME MATERIAL & GAGE AS TANK WELDED OR FUSED TO TANK ACCESS RISER (TYP.) NOT TO SCALE SECTION OUTLET IE: 26.19 12" CPEP 54" TYPE 2 CATCH BASIN ROUND SOLID COVER, WITH INVERTED FRAME MARKED "DRAIN" WITH LOCKING BOLTS. MAX. W.S. = 28.19 18-INCH FLOW CONTROL RISER 0.5' 2.0' LIVE STORAGE 0.5' DEAD STORAGE 2.0' MIN 2.0' MIN SHEAR GATE PRIMARY OVERFLOW ROUTE ELEV=28.19 IE: 25.69 (36" CMP) NOTES: 1.PIPE SLOPES PER PLANS. 2.PIPE SUPPORTS AND RESTRICTOR SHALL BE OF SAME MATERIAL, AND BE ANCHORED AT 3' MAX. SPACING BY 5/8" DIA. STAINLESS STEEL EXPANSION BOLTS OR EMBEDDED 2" IN WALL. (SUPPORT BRACKETS SHALL BE 3" x 0.090 GAGE) 3.THE RESTRICTOR SHALL BE FABRICATED FROM .060" ALUMINUM, OR .064" ALUMINIZED STEEL, OR .064" GALVANIZED STEEL PIPE; IN ACCORDANCE WITH AASHTO M 36, M 196, M 197 AND M 274. GALVANIZED STEEL SHALL HAVE TREATMENT I. 4.OUTLET SHALL BE CONNECTED TO CULVERT OR SEWER PIPE WITH A STANDARD COUPLING BAND FOR CORRUGATED METAL PIPE, OR GROUTED INTO THE BELL OF CONCRETE PIPE. 5.THE VERTICAL RISER STEM OF THE RESTRICTOR / SEPARATOR SHALL BE 18" MIN. DIA. 6.FRAME AND LADDER OR STEPS OFFSET SO THAT: A.CLEANOUT GATE IS VISIBLE FROM TOP. B.CLIMB DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C.FRAME IS CLEAR OF CURB. 7.IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS I/4". 8.MULTI-ORIFICE ELBOWS MAY BE LOCATED AS SHOWN OR ALL ON ONE SIDE OF RISER TO ASSURE LADDER CLEARANCE. 9.ALL METAL PARTS SHALL BE CORROSION RESISTANT. ELEV. = 24.19 WELDED PLATE WITH ORIFICE Ø = 2 5 8" COUPLING BAND RECTANGULAR WEIR BOTTOM EL: 27.62 FRAME AND LADDER OR STEPS OFFSET. SEE NOTE 6. 2.5" COUPLING BAND 1 NOT TO SCALE STORM PROFILE 4 NOT TO SCALE ACCESS RISERS 2 NOT TO SCALE CONTROL STRUCTURE 2 C5.10 4 C5.10 VARIABLE LENGTH. 1" ROD OR TUBING, HOOK WITH LOCK SCREW. ADJUSTABLE LOCK LOCK PIN. HANDLE WITH FRONT LEVEL LINE LIFT HANDLE MAXIMUM OPENING OF GATE LIFT HANDLE SIDE SEE NOTE 5LEVEL LINENOTES: 1. SHEAR GATE SHALL BE ALUMINUM ALLOY PER ASTM B-26-ZG-32a 2. GATE SHALL BE 8" DIAM. UNLESS OTHERWISE SPECIFIED. 3. GATE SHALL BE JOINED TO TEE SECTION BY BOLTING (THROUGH FLANGE), WELDING, OR OTHER SECURE MEANS. 4. LIFT ROD: HANDLE EXTENDING TO WITHIN ONE FOOT OF COVER AND ADJUSTABLE HOOK LOCK FASTENED TO FRAME OR UPPER HANDHOLD. 5. GATE SHALL NOT OPEN BEYOND THE CLEAR OPENING BY LIMITED HINGE MOVEMENT, STOP TAB, OR SOME OTHER DEVICE. 6. NEOPRENE RUBBER GASKET REQUIRED BETWEEN RISER MOUNTING FLANGE AND GATE FLANGE. 7. MATING SURFACES OF LID AND BODY TO BE MACHINED FOR PROPER FIT. 8. FLANGE MOUNTING BOLTS SHALL BE 3/8" DIAM. STAINLESS STEEL. 9. ALTERNATE CLEANOUT/SHEAR GATES TO THE DESIGN SHOWN ARE ACCEPTABLE, PROVIDED THEY MEET THE MATERIAL SPECIFICATIONS ABOVE AND HAVE A SIX BOLT, 10 3/8" BOLT CIRCLE FOR BOLTING TO THE FLANGE CONNECTION. SIX EVENLY SPACED HOLES ON 10 3/8" BOLT CIRCLE FOR BOLTING TO FLANGE CONNECTION. LIFT HANDLE SHALL BE ATTACHED TO SHEAR GATE. 3 NOT TO SCALE SHEAR GATE 3 C5.10 FRAME AND LADDER OR STEPS OFFSET. SEE NOTE 6 FLOW CONTROL DETAILS R-420014 GRAVEL BACKFILL FOR PIPE ZONE BEDDING PER W.S.D.O.T. 9-03.12(3), 95% COMPACTION. IF SUBGRADE DOES NOT MEET COMPACTION REQUIREMENTS FOR SUPPORT OF THE UTILITY, OVER EXCAVATE TO PROVIDE A MINIMUM OF 12-INCHES OF QUARRY SPALLS PLACED OVER A GEOTEXTILE SUCH AS MIRAFI 500X OR EQUIVALENT APPROVED BY THE GEOTECHNICAL ENGINEER. 07/26/2022 DEVELOPMENT ENGINEERING JChavez 07/27/2022 UP UP 64'-8 1 / 4" 17'-9 1/ 4" 25'-6" 21'-5" 63'-8 1/4"1'-2"42'-11"20'-9 1/4"5'-3 3/8"172'-2 1/8"58'-10 1/2"45'-0"192'-7 1/4"46'-4 3/4"53'-7 1/4"67'-9 3/4"20'-0"60'-1 1/4"54'-11 7/ 8" 69'-1 1 1/ 8" 38'-6 7/8" 3'-6" 4'-0" 108'- 6"12'-6"11'-0 1/4" 69'-1 1 1/ 8" J J W-1 W-2A 313232 323 2 323233 33PROPOSED MULTIFAMILY BUILDING FFE=32.08 SSCO #3 2 7 1 EXISTING 18" WATER 9 6 PROPOSED ROW DEDICATION LINE 10+69 5+006 +0 07+008+00 9+00 10+00 EP: 10+68.73PI: 6 + 4 4. 7 0 PI: 7+71.77 PI : 8+12 .97PI: 9+58.88PI: 8+81.29PI: 5+03.00 PI: 5+35.31 HORIZONTAL DEFLECTIONS AS NECESSARY PER HALF MANUFACTURERS RECOMMENDATIONS 8 2 PROFILE 1 START N 175874.54 E 1300625.99 PROFILE 2 END N 176127.86 E 1300805.11 15.00' WATER EASEMENT 4" WATER METER VAULT STA:9+08.47, 15.88' RT DETECTOR DOUBLE CHECK VALVE ASSEMBLY (DDCVA) STA:9+01.47, 16.50' RT FIRE HYDRANT ASSEMBLY STA:7+87.02, 34.47' LT FIRE DEPARTMENT CONNECTION (FDC) STA:7+89.12, 40.72' LT 101LF 6" DIP CL 52 53LF 6" DIP CL 52 12LF 6" DIP CL 52 12LF 6" DIP CL 52 POST INDICATOR VALVE (PIV) STA:8+92.38, 25.78' RT 34LF 6" DIP CL 52 8" X 6" TEE IE: 25.06 8" (NW) IE: 25.06 8" (SE) IE: 25.14 6" (NE) 3 3 TRANSFORMER PAD SEE ELECTRICAL PLAN SSCO #1 6 5 5 10 W-2 W-3 W-5W-4 W-6 W-7 W-8 127LF 10 " D IP CL 52 15LF 10" DIP CL 52 26LF 10" DIP CL 52 88LF 10" DIP CL 52 7LF 10" DIP CL 52 24LF 6" DIP CL 52 7.50' 15.00' 11 12 7.50' EXISTING WATER SERVICE TO BE RETIRED (SEE DEMO PLAN). 15' WATER EASEMENT 13 W-10 W-11 1" DCVA SEE LANDSCAPING SHEET L 3.0 CRANE FOUNDATION PER STRUCTURAL 7.50' 10.00' 10.00' BUILDING OVERHANG W-9 10LF 6" DIP CL 52 1 LF 6" PVC @ 2.00% SSCO #1A CONNECT TO BUILDING (SEE MECHANICAL FOR CONTINUATION) IE: 25.17 8" (SW) SSCO #2 84 LF 8 " P V C @ 2 . 0 0 % 3LF 10" DIP CL 52 40LF 10" DIP CL 52 84LF 10" DIP CL 52 (RJ) 30LF 6" DIP CL 52 W-12 28LF 3" DIP CL 52 31LF 10" DIP CL 52 W-2B 15.23' ENCLOSURE SHALL BE WOODEN FENCING, PER DETAIL 8 ON SHEET L1.2 31LF 10" DIP CL 52 1 0 9LF 10 " D IP C L 5 2 WATER STRUCTURE TABLE W # W-1 W-2 W-2A W-2B W-3 W-4 W-5 W-6 W-7 W-8 W-9 W-10 W-11 W-12 STATION DESCRIPTION STA: 5+00.00, 0.00' CONNECT TO EXISTING WATER MAIN (BY CITY FORCES) PER COR STD PLAN 300.1 1 - 18" X 10" TAPPING TEE (MJ X FL) 1 - 10" TAPPING GATE VALVE (FL X MJ) 1 - THRUST BLOCK STA: 6+44.70, 0.00' 1 - 10" 11.25° BEND (MJ X MJ) 1 - THRUST BLOCK STA: 5+03.00, 0.00' 1 - 10" 22.5° BEND (MJ X MJ) 1 - THRUST BLOCK STA: 5+35.31, 0.00' 1 - 10" 45° BEND (MJ X MJ) 1 - THRUST BLOCK STA: 7+71.77, 0.00' 1 - 10" 90° BEND (MJ X MJ) 1 - THRUST BLOCK STA: 7+87.02, 0.00' 1 - 10" X 6" TEE (FL X FL) 1 - 6" GATE VALVE (FL X MJ) 1 - 10" GATE VALVE (FL X MJ) 1 - 10" ADAPTER (FL X MJ) 1 - THRUST BLOCK STA: 8+12.97, 0.00' 1- 10" 11.25° BEND (MJ X MJ) 1 - THRUST BLOCK STA: 9+01.47, 0.00' LT 1 - 10" X 6" TEE (FL X FL) 1 - 6" GATE VALVE (F L X MJ) 1 - 10" GATE VALVE (F LX MJ) 1 - 10" FL X MJ ADAPTER 1 - THRUST BLOCK STA: 9+08.47, 0.00' RT 1 - 10" X 6" TEE (FL XFL) 1 - 6" GATE VALVE (F L X MJ) 1 - 10" GATE VALVE (F L X MJ) 1 - 10" FL X MJ ADAPTER 1 - THRUST BLOCK STA: 10+63.73, 0.00' RT CONNECT TO EXISTING WATER MAIN CUT IN TEE (BY CITY FORCES) PER COR STD PLAN 300.4 1 - 12" X 10" TEE (FL X FL) 1 - 10" GATE VALVE (FL X MJ) 2 - 12" GATE VALVE (FL X MJ) 2 - 12" SOLID SLEEVES (MJ) 1 - 10" SOLID SLEEVE (MJ) 1 - THRUST BLOCK STA: 5+00.10, -9.74' LT CONNECT TO EXISTING WATERMAIN BY CITY FORCES WITH CUT IN TEE & ONE VALVE PER STD PLAN 300.1 1 - 18” X 6” TEE (FL X FL) 2 - 18” ADAPTERS (FL X MJ) 1 - 6” GATE VALVE (FL X MJ) 1 - THRUST BLOCK STA: 9+08.47, 12.00' RT 1 - 6" X 4" REDUCER (MJ X FL) STA: 9+08.47, 19.75' RT 1 - 6" X 4" REDUCER (MJ X FL) STA: 10+24.63, 0.00' 1 - 3" WET TAP PER COR STD PLAN 300.1 1 - THRUST BLOCK SEWER CLEANOUT TABLE STRUCTURE NAME SSCO #1 SSCO #1A SSCO #2 SSCO #3 STRUCTURE DETAILS RIM = 31.73 IE = 24.74 (8" NW) IE = 24.74 (8" SW) RIM = 31.67 IE = 24.45 (8" NE) IE = 24.45 (8" SW) RIM = 31.90 IE = 25.17 (6" SW) RIM = 31.94 IE = 25.14 (8" NE) IE = 25.14 (8" SE) CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-4200WATERSHED APARTMENTS CIVIL CONSTRUCTION PERMITWATERSHED APARTMENTSbelow.Know what'sCallbefore you dig. R Civil Engineers Structural Engineers Landscape Architects Community Planners Land Surveyors Neighbors T A C O M A 2215 North 30th Street, Suite 300, Tacoma, WA 98403253.383.2422TEL S E A T T L E 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101206.267.2425TEL C21005115 LUA21-000239PR21-000258WATERSHED APARTMENTSGRAPHIC SCALE 0 20 40 1" = 20 FEET 10 N KEYNOTES PROPOSED HYDRANT ASSEMBLY PER COR STD PLN. 310.1. CONNECT TO WATER MAIN WITH CUT-IN TEE AND THREE VALVES, PER STD PLAN 300.4. CONNECT TO WATER MAIN WITH A 10" x 6" FL x FL TEE. CONNECT TO EXISTING MANHOLE, RECHANNELIZE STRUCTURE, SEE DETAIL 5/C6.8. CONNECT TO BUILDING PLUMBING, SEE MECHANICAL PLAN FOR CONTINUATION. SEE DRAINAGE PLAN FOR DRAINAGE DESIGN. UNDERGROUND POWER, SEE ELECTRICAL PLAN FOR DETAILS GAS SERVICE. FIRE SPRINKLER SERVICE 4-INCH DOMESTIC SERVICE LOCATION OF 18” WATER MAIN ON S GRADY WAY SHALL BE FIELD VERIFIED BY CONTRACTOR DURING CONSTRUCTION. IF LOCATION DIFFERS FROM SURVEYED LOCATION, CONTRACTOR MUST NOTIFY THE CITY AND SUBMIT A DESIGN REVISION PRIOR TO CONNECTING TO THE EXISTING WATER MAIN. PROVIDE VERTICAL CROSS FOR POLYPIG STATION FOR CLEANING OF WATER MAINS PER STD. PLAN 300.6 1" IRRIGATION METER CONCRETE ENCASEMENT ON SEWER PIPE. LENGTH OF SEWER PIPE TO BE CENTERED AT POINT OF CROSSING SO THAT JOINTS ARE AS FAR AS POSSIBLE FROM THE WATER LINE. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 LEGEND: RIGHT-OF-WAY/PROPERTY LINE CENTERLINE GAS PIPE SANITARY PIPE WATER PIPE FIRE SERVICE PIPING FIRE HYDRANT METER AS NOTED GATE VALVE THRUST BLOCKING PER STD PLANS 330.1 AND 330.2. FITTINGS AS NOTED PIV FDC SANITARY SEWER CLEANOUT 1 C6.20 1 C6.20 1 C6.20 2 C6.30 1 C6.30 2 C6.80 5 C6.80 5 C6.80 2 C6.70 1 C6.70 1 C6.60 2 C6.40 1 C6.50 1 C6.40 2 C6.40 3 C6.80 3 C6.40 2 C6.50 2 C6.40 3-FOOT DIAMETER CMP DETENTION TANK 5.4' ROW DEDICATION 5.0' ROW DEDICATION EXISTING ROW LINE PROPOSED ROW DEDICATION LINE EXISTING 12" WATER EXISTING HYDRANT PROFILE 1 END PROFILE 2 START UTILITY PLAN SEWER PROFILE START SEWER PROFILE END W-420001 S-420001WTRP-27-4200NOTES 1. MAXIMUM ALLOWABLE DEFLECTION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. 2. ALL WATER FITTINGS AND VALVES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAVE A WEDGE-TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 3. CONCRETE THRUST BLOCKS ARE REQUIRED ON ALL FITTINGS PER COR STD PLANS 330.2 AND 330.3. 4. WHERE NEW WATER MAIN CROSS A NON-POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 5. WATER MAIN TO BE CONSTRUCTED FOLLOWING GEO-PIER INSTALLATION. 07/26/2022 DEVELOPMENT ENGINEERING JChavez 07/27/2022 20 25 30 35 20 25 30 35 8" STORM** BOT 28.12 8" STORM** TOP 27.00 24" CPEP STORM TOP 28.23 FG 31.465+50FG 31.77FG 31.926+00FG 32.54FG 33.206+50FG 33.08FG 32.717+00FG 32.35FG 31.947+50FG 31.84FG 32.06DEFLECTIONS AS NECESSARY, PER HALF MANUFACTURERS RECOMMENDATIONS TO PROVIDE MINIMUM 2.0' OF COVER AND MAXIMUM 5.0' OF COVER 3.12' PROPOSED ROW DEDICATION 1.5' MIN 15 LF 10" DIP CL 52 1.5' MIN *P(UG) - APPROXIMATE EXISTING UNDERGROUND POWER PROPOSED GRADE AT WATER ℄EXISTING GRADE AT WATER ℄ STA: 7+71.77 1 - 10" 90° BEND (MJ x MJ) 1 - THRUST BLOCK 18 LF 10" DIP CL 52 127 LF 10" DIP CL 5 2 VB #1 VB #2 STA: 5+00.00 CONNECT TO EXISTING WATER MAIN (BY CITY FORCES) PER COR STD PLAN 300.1 1 - 18" x 10" TAPPING TEE (MJ x FL) 1 - 10" TAPPING GATE VALVE (FL x MJ) 1 - THRUST BLOCK 2.28' 4 LF 10" DIP CL 52 STA: 6+44.70 1 - 10" 11.25° BEND (MJ x MJ) 1 - THRUST BLOCK 127 LF 10" DIP CL 5 2 STA: 7+87.02 1 - 10" x 6" TEE (FL x FL) 1 - 6" GATE VALVE (FL x MJ) 1 - 10" GATE VALVE (FL x MJ) 1 - 10" ADAPTER (FL x MJ) 1 - THRUST BLOCK PROPOSED SEWER 14 LF 10" DIP CL 52 STA: 5+03.00 1 - 10" 22.5° BEND (MJ x MJ) 1 - THRUST BLOCK STA: 5+35.31 1 - 10" 45° BEND (MJ x MJ) 1 - THRUST BLOCK 6" DI STORM BOT 29.49 ETHAFOAM PAD 20 25 30 35 20 25 30 35 18" STORM BOT 27.09 FG 32.048+50FG 31.79FG 31.729+00FG 32.09FG 32.459+50FG 31.68FG 30.7810+00FG 30.41FG 30.1110+50FG FG1.51' 5.67' DEFLECTIONS AS NECESSARY, PER HALF MANUFACTURERS RECOMMENDATIONS TO PROVIDE MINIMUM 3.0' OF COVER AND MAXIMUM 6.0' OF COVER 5.14' 1.5' MIN 5.04' PROPOSED ROW DEDICATION APPROX. LOCATION OF EXISTING GAS PROPOSED STORM** PROPOSED FIRE PIPE 1.61' PROPOSED STORM** EXISTING GRADE AT WATER ℄ PROPOSED GRADE AT WATER ℄ PROPOSED GRADE AT WATER ℄ EXISTING GRADE AT WATER ℄ STA: 9+01.47 1 - 10" x 6" TEE (FL x FL) 1 - 6" GATE VALVE (F L x MJ) 1 - 10" GATE VALVE (F Lx MJ) 1 - 10" FL x MJ ADAPTER 1 - THRUST BLOCK STA: 9+08.47 1 - 10" x 6" TEE (FL xFL) 1 - 6" GATE VALVE (F L x MJ) 1 - 10" GATE VALVE (F L x MJ) 1 - 10" FL x MJ ADAPTER 1 - THRUST BLOCK STA: 8+12.97 1- 10" 11.25° BEND (MJ x MJ) 1 - THRUST BLOCK 1.50' 7 LF 10" DIP CL 52 STA: 10+63.73 CONNECT TO EXISTING WATER MAIN CUT IN TEE (BY CITY FORCES) PER COR STD PLAN 300.4 1 - 12" x 10" TEE (FL x FL) 1 - 10" GATE VALVE (FL x MJ) 2 - 12" GATE VALVE (FL x MJ) 2 - 12" SOLID SLEEVES (MJ) 1 - 10" SOLID SLEEVE (MJ) 1 - THRUST BLOCK INSTALL 84 LF OF 10" D.I. RESTRAINED JOINT WATER MAIN INSIDE OF 20-INCH STEEL CASING 31 LF 10" DIP CL 52 39 LF 10" DIP CL 52 VERTICAL BEND TABLE VB # VB #1 VB #2 STATION DESCRIPTION STA: 5+04.17 1-10" 11.25° VERTICAL BEND (MJ X MJ) 1- THRUST BLOCK STA: 5+17.73 1- 10" 11.25° VERTICAL BEND (MJ X MJ) 1- THRUST BLOCK CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-4200WATERSHED APARTMENTS CIVIL CONSTRUCTION PERMITWATERSHED APARTMENTSbelow.Know what'sCallbefore you dig. R Civil Engineers Structural Engineers Landscape Architects Community Planners Land Surveyors Neighbors T A C O M A 2215 North 30th Street, Suite 300, Tacoma, WA 98403253.383.2422TEL S E A T T L E 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101206.267.2425TEL C21005115 LUA21-000239PR21-000258WATERSHED APARTMENTS1 SCALE: 1" = 20' H 1" = 10' V PROFILE 1 2 SCALE: 1" = 20' H 1" = 10' V PROFILE 2 2 C6.40 2 C6.40 WATER PROFILE AND NOTES APPROX. LOCATION OF EXISTING POWER IN AREAS OF FILL, NEW PARKING LOT AND/OR ROADWAY SUBGRADE SHALL BE FILLED AND COMPACTED BEFORE EXCAVATION FOR INSTALLATION OF NEW WATER MAIN. **STORM DRAIN AT CROSSING SHALL BE CL 52 DI. CENTER OF WATER MAIN PIPE AND STORM DRAIN PIPE SHALL BE CENTERED AT THE CROSSING POINT TO MAXIMIZE THE DISTANCE OF THE PIPE BELLS FROM THE CROSSING JOINT.W-420003WTRP-27-4200IN AREAS OF FILL, NEW PARKING LOT AND/OR ROADWAY SUBGRADE SHALL BE FILLED AND COMPACTED BEFORE EXCAVATION FOR INSTALLATION OF NEW WATER MAIN. 07/26/2022 DEVELOPMENT ENGINEERING JChavez 07/27/2022 install warning tape over shallow portion of the water main (wherever cover is less than 3-feet)