Loading...
HomeMy WebLinkAboutP_I-405_BRT_CUD5_30_Percent_Plans_220210_v1Cutthro at CreekIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIRRGOVERNMENTUNITEDSTATESGOVERNMENTRR CENTRAL PUGET SOUND REGIONAL TRANSIT AUTHORITYDRAWING No.:SHEET No.:REV:LOCATION ID:THE PREPARATION OF THIS DOCUMENT HAS BEEN FINANCED IN PART THROUGH A GRANT FROM THEU.S. DEPARTMENT OF TRANSPORTATION FEDERAL TRANSIT ADMINISTRATION UNDER THE URBANMASS TRANSPORTATION ACT OF 1964, AS AMENDED, AND IN PART BY THE CENTRAL PUGET SOUNDREGIONAL TRANSIT AUTHORITY DISTRICT OF WASHINGTON, AND THE STATE OF WASHINGTONREVIEWED BY:NAME:TITLE:DATE:02/03/22 | 8:55 AM | DYDOPC:\BMS\WSP-PB-US-PW-02\WSP__PETER.DYDO\D0342984\BRT-405-GZT500.DWGCONTRACT LOCATION MAPPREPARED BY:SUBMITTED BY:NAME:TITLE:DATE:I-405 BUS RAPID TRANSITSOUTH RENTON TCAE 0054-17CONTRACT UNIT DESCRIPTION 530% FINAL SUBMITTALSUBMITTAL DATE (FEBRUARY 11, 2021)R. GORMANPROJECT MANAGERBOOK405-GZT50140510SOUTH RENTON TC AND ROADWAYVOLUMENPROJECT LOCATIONFURTADO & ASSOCIATES, INC.Consulting Engineers901 5TH AVE., SUITE 2710SEATTLE, WA. 98164PHONE (206) 621-1218IBI GROUP801 Second Avenue – Suite 1400Seattle WA 98104 USAtel 206 521 9091 fax 206 521 9095ibigroup.comFOR REFERENCE ONLY. ProposedTemporary Use Permit (TUP) scope ofwork is limited to soil remediation andtemporary artwork only. All otherimprovements referenced in these plansare not proposed as part of the TUPapplication. 1 405-GZT501 COVER SHEET 2 405-GZI501 INDEX OF DRAWINGS 3 405-GZI502 INDEX OF DRAWINGS 4 405-GZK501 KEY MAPS SOUTH RENTON TC AND RAINIER AVE S 8 405-CRY501 RAINIER AVE S IN RENTON 9 405-CRY502 RAINIER AVE S AND HARDIE AVE SW IN RENTON 10 405-CRY503 SOUTH RENTON TC 11 405-CRY504 LAKE AVE S 12 405-CRY505 S GRADY WAY 22 405-CAV504 SOUTH RENTON TC AND LAKE AVE S 23 405-CDP501 SOUTH RENTON TC 24 405-CDP502 SOUTH RENTON TC 25 405-CDP503 RAINIER AVE S SOUTH RENTON TC & RAINIER AVE S 5 405-RPP501 SOUTH RENTON TC 6 405-RPP502 SOUTH RENTON TC 12 405-CRY505 S GRADY WAY 13 405-CXP501 SOUTH RENTON TC 14 405-CXP502 RAINIER AVE S 6 405-RPP502 SOUTH RENTON TC 7 405-RMP501 SOUTH RENTON TC 14 405-CXP502 RAINIER AVE S 15 405-CAP501 SOUTH RENTON TC 16 405-CAP502 RAINIER AVE S 16 405-CAP502 RAINIER AVE S 17 405-CPP501 SOUTH RENTON TC 18 405-CPP502 RAINIER AVE S 18 405-CPP502 RAINIER AVE S 19 405-CAV501 SOUTH RENTON TC 20 405-CAV502 SOUTH RENTON TC 21 405-CAV503 SOUTH RENTON TC 22 405-CAV504 SOUTH RENTON TC AND LAKE AVE S 28 405-CDD503 SOUTH RENTON TC 29 405-UCP501 SOUTH RENTON TC 30 405-UCP502 RAINIER AVE S 30 405-UCP502 RAINIER AVE S 31 405-CMP501 SOUTH RENTON TC 32 405-CMP502 RAINIER AVE S 33 405-TSP502 RAINIER AVE S & HARDIE AVE SW RAINIER AVE S & S GRADY WAY IN RENTON33405-TSP502 RAINIER AVE S & HARDIE AVE SW 34 405-TIP501 RAINIER AVE S & S GRADY WAY IN RENTON 35 405-TIP502 RAINIER AVE S & HARDIE AVE SW IN RENTON SOUTH RENTON TRANSIT CENTER35405-TIP502 RAINIER AVE S & HARDIE AVE SW IN RENTON 36 405-TNP501 SOUTH RENTON TRANSIT CENTER 37 405-TNP502 RAINIER AVE S SOUTH RENTON TRANSIT CENTER38405-ASP501 SOUTH RENTON TRANSIT CENTER SOUTH RENTON TRANSIT CENTER & RAINIER AVE S38405-ASP501 SOUTH RENTON TRANSIT CENTER 39 405-LHP501 SOUTH RENTON TRANSIT CENTER & RAINIER AVE S SOUTH RENTON TRANSIT CENTER & RAINIER AVE S39405-LHP501 SOUTH RENTON TRANSIT CENTER & RAINIER AVE S 40 405-LPP501 SOUTH RENTON TRANSIT CENTER & RAINIER AVE S SOUTH RENTON TRANSIT CENTER & RAINIER AVE S40405-LPP501 SOUTH RENTON TRANSIT CENTER & RAINIER AVE S 41 405-LRP501 SOUTH RENTON TRANSIT CENTER & RAINIER AVE S 43 405-ELP502 RAINIER AVE S & HARDIE AVE SW IN RENTON 44 405-JEP501 SOUTH RENTON TC 45 405-JEP502 SOUTH RENTON TC 46 405-JEP503 SOUTH RENTON TC 47 405-JEP504 SOUTH RENTON TC 25 405-CDP503 RAINIER AVE S 26 405-CDD501 SOUTH RENTON TC & RAINIER AVE S 27 405-CDD502 SOUTH RENTON TC 28 405-CDD503 SOUTH RENTON TC 42 405-ELP501 SOUTH RENTON TC 43 405-ELP502 RAINIER AVE S & HARDIE AVE SW IN RENTON No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/02/22 | 6:11 PM | DYDOPC:\BMS\WSP-PB-US-PW-02\WSP__PETER.DYDO\D0342984\BRT-405-GZI500.DWGBRT-405-GZI500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 INDEX OF DRAWINGS NTS CONTRACT UNIT DESCRIPTION 5 GENERAL INDEX OF DRAWINGS 405-GZI501 2 0 SHT. No.DWG. No.TITLEREV DEMOLITION AND REMOVAL PLANS RIGHT-OF-WAY PLANS ROADWAY TYPICAL SECTIONS GENERAL RIGHT-OF-WAY MONUMENTATION PLANS ALIGNMENT PLAN AND DATA DRAINAGE PLANS COMPOSITE UTILITY PLANS PAVING PLANS PAVEMENT MARKING PLANS VERTICAL ALIGNMENT AND SUPERELEVATION PLANS SIGNAL PLANS TRAFFIC SIGNAL PRIORITY PLANS SIGNING PLANS STATION PLATFORM PLANS HARDSCAPE PLANS PLANTING PLANS IRRIGATION PLANS STATION ELECTRICAL AND COMMUNICATION PLAN DRAINAGE DETAILS LIGHTING PLANS 92 405-MHN501 HVAC LEGENDS AND ABBREVIATIONS SOUTH RENTON TC 93 405-MHN502 HVAC GENERAL NOTES SOUTH RENTON TC 94 405-MHP501 HVAC PLAN - LEVEL 1 SOUTH RENTON TC 95 405-MHP502 HVAC PLAN - LEVEL 2 SOUTH RENTON TC 96 405-MHP504 HVAC PLAN - LEVEL 4 SOUTH RENTON TC 97 405-MHP505 HVAC ENLARGED PLAN - LEVEL 1 SOUTH RENTON TC 98 405-MHP506 HVAC ENLARGED PLAN - LEVEL 1 SOUTH RENTON TC 99 405-MHP507 HVAC ENLARGED PLAN - LEVEL 2 AND 4 SOUTH RENTON TC 100 405-MHS501 HVAC CONTROL SCHEMATICS SOUTH RENTON TC 101 405-MHS502 HVAC SCHEDULES SOUTH RENTON TC 102 405-MHS503 HVAC SCHEDULES SOUTH RENTON TC 103 405-MHD501 HVAC DETAILS SOUTH RENTON TC PLUMBING LEGENDS AND ABBREVIATIONS SOUTH RENTON TC103405-MHD501 HVAC DETAILS SOUTH RENTON TC 104 405-MPN501 PLUMBING LEGENDS AND ABBREVIATIONS SOUTH RENTON TC 105 405-MPP501 PLUMBING PLAN LEVEL B1 SOUTH RENTON TC 106 405-MPP502 PLUMBING PLAN LEVEL 1 SOUTH RENTON TC 107 405-MPP503 PLUMBING PLAN LEVEL 2 SOUTH RENTON TC 108 405-MPP506 PLUMBING PLAN LEVEL 5 SOUTH RENTON TC 109 405-MPS501 PLUMBING RISER SOUTH RENTON TC 110 405-MPS502 PLUMBING SCHEDULES SOUTH RENTON TC FIRE PROTECTION LEGENDS AND ABBREVIATIONS SOUTH RENTON TC 110 405-MPS502 PLUMBING SCHEDULES SOUTH RENTON TC 111 405-MFN501 FIRE PROTECTION LEGENDS AND ABBREVIATIONS SOUTH RENTON TC 112 405-MFN502 FIRE PROTECTION GENERAL NOTES SOUTH RENTON TC 113 405-MFP501 FIRE PROTECTION PLAN - LEVEL 1 SOUTH RENTON TC 114 405-MFP502 FIRE PROTECTION PLAN - LEVEL 2 SOUTH RENTON TC 115 405-MFP503 FIRE PROTECTION PLAN - LEVEL 3 SOUTH RENTON TC 116 405-MFP504 FIRE PROTECTION PLAN - LEVEL 4 SOUTH RENTON TC 117 405-MFP505 FIRE PROTECTION PLAN - LEVEL 5 SOUTH RENTON TC 118 405-MFD501 FIRE PROTECTION DETAILS SOUTH RENTON TC 119 405-EPN501 ELECTRICAL LEGENDS AND ABBREVIATIONS SOUTH RENTON TC 120 405-ESP501 ELECTRICAL GARAGE SITE PLAN SOUTH RENTON TC 121 405-EPP501 POWER PLAN - LEVEL 1 SOUTH RENTON TC 122 405-EPP502 POWER PLAN - LEVEL 2 SOUTH RENTON TC 123 405-EPP503 POWER PLAN - LEVEL 3 SOUTH RENTON TC 124 405-EPP504 POWER PLAN - LEVEL 4 SOUTH RENTON TC 125 405-EPP505 POWER PLAN - LEVEL 5 SOUTH RENTON TC 126 405-EEP501 ELECTRICAL ENLARGED PLANS SOUTH RENTON TC 127 405-EPS501 ELECTRICAL ONE LINE SOUTH RENTON TC 128 405-ETN501 TECHNOLOGY LEGENDS AND ABBREVIATIONS SOUTH RENTON TC 129 405-ETP501 TECHNOLOGY PLAN - LEVEL 1 SOUTH RENTON TC 130 405-ETP502 TECHNOLOGY PLAN - LEVEL 2 SOUTH RENTON TC 131 405-ETP503 TECHNOLOGY PLAN - LEVEL 3 SOUTH RENTON TC 132 405-ETP504 TECHNOLOGY PLAN - LEVEL 4 SOUTH RENTON TC 133 405-ETP505 TECHNOLOGY PLAN - LEVEL 5 SOUTH RENTON TC 134 405-ETE501 TECHNOLOGY ENLARGED PLANS SOUTH RENTON TC 135 405-ETD501 TECHNOLOGY DETAILS SOUTH RENTON TC 71 405-AZN501 GENERAL ARCHITECTURAL ABBREVIATIONS & SYMBOLS SOUTH RENTON TC 72 405-AZN502 GENERAL ARCHITECTURAL NOTES SOUTH RENTON TC 73 405-AZN503 BUILDING CODE INFORMATION SOUTH RENTON TC 74 405-AZP501 GARAGE EXITING PLAN - LEVEL 1 AND 2 SOUTH RENTON TC 75 405-AZP502 GARAGE EXITING PLAN - LEVEL 3 AND 4 SOUTH RENTON TC 76 405-AZP503 GARAGE EXITING PLAN - LEVEL 5 SOUTH RENTON TC 77 405-ASP501 GARAGE SITE PLAN SOUTH RENTON TC 78 405-APP501 GARAGE FLOOR PLAN - LEVEL 1 SOUTH RENTON TC 79 405-APP502 GARAGE FLOOR PLAN - LEVEL 2 SOUTH RENTON TC 80 405-APP503 GARAGE FLOOR PLAN - LEVEL 3 SOUTH RENTON TC 81 405-APP504 GARAGE FLOOR PLAN - LEVEL 4 SOUTH RENTON TC 82 405-APP505 GARAGE FLOOR PLAN - LEVEL 5 SOUTH RENTON TC 83 405-APP506 GARAGE ENLARGED FLOOR PLAN SOUTH RENTON TC 84 405-APP507 GARAGE ENLARGED FLOOR PLAN SOUTH RENTON TC 85 405-APP508 GARAGE ENLARGED FLOOR PLAN SOUTH RENTON TC 86 405-ARP501 GARAGE ROOF PLAN SOUTH RENTON TC 87 405-AEE501 GARAGE EXTERIOR ELEVATIONS - NORTH AND EAST SOUTH RENTON TC 88 405-AEE502 GARAGE EXTERIOR ELEVATIONS - SOUTH AND WEST SOUTH RENTON TC 89 405-AEE503 GARAGE EXTERIOR 3D - NW/SE VIEWS SOUTH RENTON TC 90 405-AEE504 GARAGE EXTERIOR 3D - NE/SW VIEWS SOUTH RENTON TC 91 405-AEX501 GARAGE LONGITUDINAL AND TRANSVERSE SECTIONS SOUTH RENTON TC 48 405-SZN501 GENERAL NOTES SOUTH RENTON TC 49 405-SZN502 GENERAL NOTES SOUTH RENTON TC 50 405-SZN503 GENERAL NOTES SOUTH RENTON TC 51 405-SZN504 GENERAL NOTES SOUTH RENTON TC 52 405-SFP501 FOUNDATION PLAN SOUTH RENTON TC 53 405-SGP501 SLAB PLAN - LEVEL 1 AND 1.5 SOUTH RENTON TC 54 405-SGP502 FRAMING PLAN - LEVEL 2 AND 2.5 SOUTH RENTON TC 55 405-SGP503 FRAMING PLAN - LEVEL 3 AND 3.5 SOUTH RENTON TC 56 405-SGP504 FRAMING PLAN - LEVEL 4 AND 4.5 SOUTH RENTON TC 57 405-SGP505 FRAMING PLAN - LEVEL 5 AND 5.5 SOUTH RENTON TC 58 405-SZE501 ELEVATIONS SOUTH RENTON TC 59 405-SZE502 ELEVATIONS SOUTH RENTON TC 60 405-SZX501 SECTIONS SOUTH RENTON TC 61 405-SZX502 SECTIONS SOUTH RENTON TC 62 405-SZD501 TYPICAL CONCRETE DETAILS SOUTH RENTON TC 63 405-SZD502 TYPICAL CONCRETE DETAILS SOUTH RENTON TC 64 405-SZD503 TYPICAL CONCRETE DETAILS SOUTH RENTON TC 65 405-SZD504 TYPICAL CONCRETE DETAILS SOUTH RENTON TC 66 405-SZD505 TYPICAL CONCRETE DETAILS SOUTH RENTON TC 67 405-SZD506 TYPICAL CONCRETE DETAILS SOUTH RENTON TC 68 405-SZD507 TYPICAL CONCRETE DETAILS SOUTH RENTON TC 69 405-SZD508 TYPICAL CONCRETE DETAILS SOUTH RENTON TC 70 405-SZD509 TYPICAL CMU DETAILS SOUTH RENTON TC SHT. No.DWG. No.TITLEREV SHT. No.DWG. No.TITLEREV INDEX OF DRAWINGS DES DWN CHK APP 1" = 40' CONTRACT UNIT DESCRIPTION 5 GENERAL INDEX OF DRAWINGS 405-GZI502 3 ---- No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/03/22 | 4:03 PM | DYDOPC:\BMS\WSP-PB-US-PW-02\WSP__PETER.DYDO\D0342984\BRT-405-GZI500.DWGBRT-405-GZI500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 GARAGE HVAC PLANS AND DETAILS GARAGE PLUMBING PLANS AND DETAILS GARAGE FIRE PROTECTION PLANS AND DETAILS GARAGE ELECTRICAL PLANS AND DETAILS GARAGE STRUCTURAL PLANS AND DETAILS GARAGE ARCHITECTURAL PLANS AND DETAILS SW GRA D Y W A Y SW 7TH ST RAINIERAVE SHARDIEAVE SWSR-167I-405SW GRA D Y W A Y SW 7TH ST RAINIERAVE SHARDIEAVE SWSR-167I-405SW GRA D Y W A Y SW 7TH ST RAINIERAVE SHARDIEAVE SWSR-167SW GRA D Y W A Y SW 7TH ST RAINIERAVE SHARDIEAVE SWSR-167CONTRACT UNIT DESCRIPTION 5 GENERAL KEY MAPS SOUTH RENTON TC AND RAINIER AVE S 405-GZK501 4 0 1" = 300' N SCALE IN FEET 0150 300300 600 (1" = 300') SOUTH RENTON TRANSIT CENTER STATION LAKE AVE S END WORK BEGIN WORK No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/03/22 | 8:47 AM | DYDOPC:\BMS\WSP-PB-US-PW-02\WSP__PETER.DYDO\D0342984\BRT-405-GZK500.DWGBRT-405-GZK500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 LHP - HARDSCAPE CROSS REFERENCING OF DRAWINGS BASE SHEET TITLE 1"=20' DRAWING SETS 405-**P501 405-**P502 01 02 **P = DESIGN ELEMENT PLAN VIEW DESIGNATION SOUTH RENTON TRANSIT CENTER STATION LAKE AVE S END WORK BEGIN WORK CAP - ALIGNMENT CDP - DRAINAGE CMP - PAVEMENT MARKING CPP - PAVING CXP - DEMOLITION AND REMOVAL ELP - ILLUMINATION LPP - PLANTING LRP - IRRIGATION TNP - SIGNING UCP - COMPOSITE UTILITY CROSS REFERENCING OF DRAWINGS BASE SHEET TITLE 1"=40' DRAWING SETS 405-**P501 405-**P502 01 02 **P = DESIGN ELEMENT PLAN VIEW DESIGNATION 01 02 SOUTH RENTON TRANSIT CENTER STATION LAKE AVE S END WORK BEGIN WORK JEP - STATION ELECTRICAL AND COMMUNICATION CROSS REFERENCING OF DRAWINGS BASE SHEET TITLE 1"=50' DRAWING SETS 405-**P501 01 **P = DESIGN ELEMENT PLAN VIEW DESIGNATION 01 01 SCALE: 1" = 300' KEY MAP - 1"=20' SCALE SHEETS SCALE: 1" = 300' KEY MAP - 1"=40' SCALE SHEETS SCALE: 1" = 300' KEY MAP - 1"=50' SCALE SHEETS NOTE: ENLARGED ARCHITECTURE AND SYSTEMS DETAIL SHEETS NOT SHOWN IN KEY MAPS. 405-TIP502 405-TIP501 405-TSP502 405-RPP501 405-RPP502 SOUTH RENTON TRANSIT CENTER STATION LAKE AVE S END WORK BEGIN WORK CDP - DRAINAGE CROSS REFERENCING OF DRAWINGS BASE SHEET TITLE 1"=30' DRAWING SETS 405-**P501 405-**P502 01 02 **P = DESIGN ELEMENT PLAN VIEW DESIGNATION SCALE: 1" = 300' KEY MAP - 1"=30' SCALE SHEETSI-405I-405405-CDP503 01 02 XXXXXXXXXXXXXXXXXXXXXX X X X XXXXX XXXXX X XXXXXXXXX XXXXXX XSDSDSDSDSDSDSDSDSDSDSDSD SD SDSDSDSDSDSDS GRADY WAY10+0912+00 14+00BP = 10+08.61PC = 12+56.31150+00152+00154+00156+00158+00160+00161+0010+08.61, 0.00'11+4610+0019+2610+0012+0014+0016+0018+ 0 0 14+0016+0018+0018+309+7510+00 12+00 1/4 SECTION LINEDRAINAGE ESMTWATER EASEMENTEX 20' PUBLIC UTILITY ESMTREC NO. 9103110844N77°28'16"E 1041.30' (MON-TO-MON ALONG R/W CENTERLINE)50'50'50'50'50'50'65'VARIESEX 10' WATERLINE ESMTREC NO. 7408260268EX 162.5' WIDE ELECTRIC POWERTRANSMISSION ESMT (LYING SO OF7TH ST. & NO OF FORMER R.R. R/W)REC NO. 3364759EX OVERHEAD POWER ESMTREC NO. 3180315,MODIFIED BYREC NO. 86030200379REC NO. 20110812001718EX SLOPE & UTILITY ESMTREC NO. 20110812001718EX 4' SLOPE & UTILITY ESMTREC NO. 20110812001718EX. WATER ESMTREC NO. 9103110843EX 15' PUBLIC UTILITY ESMTREC NO. 9103110843EX 10' SEWER ESMTREC NO. 5292274EX 27'X80' SUPPORTSTRUCTURE ESMTREC NO. 8603020379EX 27'X80' TRANSMISSIONLINE STRUCTURE ESMTREC NO. 7910260750EX OVERHEAD POWER ESMTREC NO. 8603020379EX PUBLIC UTILITY ESMTREC NO. 8702250475RAINIER AVE S405-C-RAINIER S LINE405-C-GRADY W LINEN01°23'38"E 292.21' (R/W CENTERLINE)Δ=40°09'59"R=716.30'L=502.15'(R/W CENTERLINE)(R/W CENTERLINE)405-C-RAINIER-LAKE-DRWYMON IS 0.09' E AND 0.05'NOF PCMON #411(SEE MONUMENTATION PLANSFOR MON DATA)MON #401(SEE MONUMENTATIONPLANS FOR MON DATA)MON #423(SEE MONUMENTATIONPLANS FOR MON DATA)BEGIN 405-C-LAKEAVE S LINESTA 9+74.53N=174979.07E=1298831.71DRAINAGE ESMT10'15'10'E EEEEEEWWW W W WWWWWWWWWWSSSSSSSSSSSSSSSSSSSSWWWWWWWWWWWWWWWWWWWWWSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSWWWWWWWWWN01°23'38"E 405-C-LAKEAVE S LINE405-C-CENTERISLAND S LINEEX OVERHEAD POWER ESMTREC NO. 3180315,MODIFIED BYREC NO. 86030200379END 405-C-GRADY WAYSTA 161+00N=175028.77E=1299055.35405-C-CENTERISLAND S LINEVARIESNo.DATEDSNCHKAPPREVISIONSUBMITTED BY:DATE:REVIEWED BY:DATE:DATE:CONTRACT No.:FILENAME:SCALE:DRAWING No.:SHEET No.:REV:LINE IS 1" AT FULL SCALE DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:02/03/22 | 12:41 PM | LIN94S:\1924 - ST I-405 BRT\ROW\SHEET FILES\CUD5\BRT-405-RPP500.DWG BRT-405-RPP500FACILITY ID:PHASE 3 - 30% SUBMITTALI-405 BRTAE 0054-1702/11/22PRELIMINARY405FURTADO & ASSOCIATES, INC.Consulting Engineers901 5TH AVE., SUITE 2710SEATTLE, WA. 98164PHONE (206) 621-1218R. GORMAN02/11/22T. DAVIDSONA. ALIMOVAJ. BECKERJ. BECKER1"=40'CONTRACT UNIT DESCRIPTION 5RIGHT-OF-WAYRIGHT-OF-WAY PLANSSOUTH RENTON TRANSIT CENTER405-RPP5015SCALE IN FEET040208040(1" = 40')NSOUND TRANSITR/W NO.PARCEL NO.(TAX ACCOUNT NO.)OWNERSPARCEL AREASQ. FT.FEEACQUISITIONSQ. FT.REMAINDERSQ. FT.PERMANENTESMT SQ. FT.TEMPORARYCONSTRUCTIONESMT SQ. FT.KING CO.RECORDINGNO.1BRI-1501923059032STATE OF WASHINGTON40,091NW 1/4 NE 1/4 SEC 19, T 23 N, R 5 E; W.M.PERMANENT EASEMENT*291,362* PARCEL AREAS BELOW ARE FROM THE COUNTY ASSESSOR RECORDSSEE DWG 405-RPP502STATE OFWASHINGTON1923059032R/W NO.BRI-15019230590681923059035R/W NO.BRI-151 (RTN-001)1923059063(CPSRTA)SOUND TRANSIT1923059074345BRI-151 (RTN-001)1923059035(CPSRTA)SOUND TRANSIT149,290192305906882,371192305907443,2112(CPSRTA)SOUND TRANSIT(CPSRTA)SOUND TRANSIT(CPSRTA)SOUND TRANSITBRI-152 (RTN-002)BRI-153 (RTN-003)(CPSRTA)SOUND TRANSIT(CPSRTA)SOUND TRANSIT192305906386,249BRI-154 (RTN-004)(CPSRTA)SOUND TRANSITWSDOT LIMITED ACCESSTEMPORARY CONSTRUCTION EASEMENTPROPERTY LINELEGENDEASEMENT LINE TEMPORARYEXISTING RIGHT-OF-WAY LINESTREET CENTER LINESECTION LINER/W NO.BRI-152 (RTN-002)R/W NO.BRI-153 (RTN-003)R/W NO.BRI-154 (RTN-004)BEGIN 405-C-RAINIER LINESTA 10+08.61=405-C-GRADY WAYSTA 150+00N=174790.12E=1297981.551,395R/W CENTERLINE INTX:N=174791.22E=1297986.18NOTES:1.SEE THE INDIVIDUAL PARCEL MAPS (RECORDED, NOT INTHIS CONTRACT) FOR DETAILS OF THE ACQUISITIONS.2.SEE SHEET 405-CAP501 FOR ALIGNMENT DATA.EASEMENT LINE PERMANENT UNKNOWN UTIL X XXXXXXXXXXXXXXXXXXXXXX XXX SDSDSDRAINIER AVE S16+00 18+00 20+0010+00BP = 10+00.00 17+6510+0012+0014+0016+009+5110+0012+0014+0016+0018+0018+3014+7014+00HARDIE AVE SW1/4 SECTION LINEWATER EASEMENTVARIESVARIESVARIESN41°33'37"E 726.56' (R/W CENTERLINE)EX 10' WATERLINE ESMTREC NO. 7408260266EX 10' ELECTRICAL ESMTW/IN WEST 20' "AS CONSTRUCTED"REC NO. 8502040500EX 10' WATERLINE ESMTREC NO. 8506060564EX 15' UTILITIES ESMTREC NO. 8506060565EX OVERHEAD POWER ESMTREC NO. 8603020379EX 10' SEWER ESMTREC NO. 5292274EX OVERHEAD POWER ESMTREC NO. 3180315MODIFIED BYREC NO. 86030200379EX 162.5' WIDE ELECTRIC POWERTRANSMISSION ESMT (LYING SO OF7TH ST. & NO OF FORMER R.R. R/W)REC NO. 3364759EX 162.5' WIDE ELECTRIC POWEREX OVERHEAD POWER ESMTREC NO. 3180315,MODIFIED BYREC NO. 86030200379EX SLOPE & UTILITY ESMTREC NO. 20110812001718EX SLOPE & UTILITY ESMTREC NO. 20110812001718Δ=40°09'59"R=716.30'L=502.15'(R/W CENTERLINE)405-C-RAINIER S LINETO BE DEDICATEDTO CITY (26 S.F.)DRAINAGE ESMT10'10'W WWWWWWWWWWWWWWWWWW W W WWN01°23'38"E 12.15'405-C-LAKEAVE S LINE405-C-CENTERISLAND S LINEEX OVERHEAD POWER ESMTREC NO. 3180315,MODIFIED BYREC NO. 86030200379405-C-CENTERISLAND N LINE405-C-CENTERISLAND S LINE18.5' 15.5' 18. 5 ' 15.5'VARIESNo.DATEDSNCHKAPPREVISIONSUBMITTED BY:DATE:REVIEWED BY:DATE:DATE:CONTRACT No.:FILENAME:SCALE:DRAWING No.:SHEET No.:REV:LINE IS 1" AT FULL SCALE DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:02/03/22 | 12:40 PM | LIN94S:\1924 - ST I-405 BRT\ROW\SHEET FILES\CUD5\BRT-405-RPP500.DWG BRT-405-RPP500FACILITY ID:PHASE 3 - 30% SUBMITTALI-405 BRTAE 0054-1702/11/22PRELIMINARY405FURTADO & ASSOCIATES, INC.Consulting Engineers901 5TH AVE., SUITE 2710SEATTLE, WA. 98164PHONE (206) 621-1218R. GORMAN02/11/22T. DAVIDSONA. ALIMOVAJ. BECKERJ. BECKER1"=40'CONTRACT UNIT DESCRIPTION 5RIGHT-OF-WAYRIGHT-OF-WAY PLANSOUTH RENTON TRANSIT CENTER405-RPP5026SCALE IN FEET040208040(1" = 40')NNW 1/4 NE 1/4 SEC 19, T 23 N, R 5 E; W.M.SEE DWG 405-RPP501STATE OFWASHINGTON1923059032R/W NO.BRI-15019230590351923059063R/W NO.BRI-154 (RTN-004)(CPSRTA)SOUND TRANSIT(CPSRTA)SOUND TRANSIT1923059031R/W NO.BRI-149RENTON PROPHOLDING LLC1923059053R/W NO.BRI-148D & C INVESTMENTS LLCSOUND TRANSITR/W NO.PARCEL NO.(TAX ACCOUNT NO.)OWNERSPARCEL AREASQ. FT.FEEACQUISITIONSQ. FT.REMAINDERSQ. FT.PERMANENTESMT SQ. FT.TEMPORARYCONSTRUCTIONESMT SQ. FT.KING CO.RECORDINGNO.1BRI-1481923059053D & C INVESTMENTS LLC*37,702* PARCEL AREAS BELOW ARE FROM THE COUNTY ASSESSOR RECORDS3BRI-1501923059032SEE DWG 405-RPP5014BRI-151 (RTN-001)5BRI-154 (RTN-004)19230590632BRI-1491923059031RENTON PROP HOLDING LLC*189,2371923059035SEE DWG 405-RPP501SEE DWG 405-RPP5015,7336,594WSDOT LIMITED ACCESSPROPERTY LINELEGENDRIGHT-OF-WAY LINEEASEMENT LINE TEMPORARYEXISTING RIGHT-OF-WAY LINESTREET CENTER LINESECTION LINER/W NO.BRI-151 (RTN-001)R/W DEDICATIONTEMPORARY CONSTRUCTION EASEMENTPERMANENT EASEMENTNOTES:1.SEE THE INDIVIDUAL PARCEL MAPS (RECORDED NOT INTHIS CONTRACT) FOR DETAILS OF THE ACQUISITIONS.2.SEE SHEET 405-CAP501 FOR ALIGNMENT DATA.405-C-LAKEAVE S LINE BEGIN 405-C-CENTERISLAND N LINESTA 10+00N=175469.62E=1298163.69BEGIN 405-C-CENTERISLAND S LINESTA 9+51.35N=175446.52E=1298093.79EASEMENT LINE PERMANENT R A I N I E R A V E S S GRADY WAYI-405LIND AVE SWSR-167 TALBOT RD S MAPLE AVE SW I- 4 0 5S 14TH STREETS 7TH STREET1/4 SECTION LINE 1/16 SECTION LINE 303401411412300301423SW 7TH STREET1/16 SECTION LINESECTION LINESW GRADY WAYHARDIE AVE SW SHATTUCK AVE ST. DAVIDSONA. ALIMOVAJ. BECKERJ. BECKER1"=200'CONTRACT UNIT DESCRIPTION 5RIGHT-OF-WAYRIGHT-OF-WAY MONUMENTATION PLANSSOUTH RENTON TRANSIT CENTER405-RMP5017SCALE IN FEET0100200200400(1" = 200')NMONUMENT COORDINATE TABLEPOINT NO.NORTHINGEASTINGELEVATIONDESC303175885.411299146.1824.27MON IN CASE401174791.241297986.2728.10MON IN CASE411175083.391297993.3828.13MON IN CASE412175891.261298012.9525.46MON IN CASE423175017.141299002.7725.50MON IN CASENE 1/4 NE 1/4 SEC 19, T 23 N, R 5 E; W.M.NW 1/4 NE 1/4 SEC 19,T 23 N, R 5 E; W.M.SW 1/4 NE 1/4 SEC 19,T 23 N, R 5 E; W.M.SE 1/4 NE 1/4 SEC 19, T 23 N, R 5 E; W.M.NE 1/4 NW 1/4 SEC 19, T 23 N, R 5 E; W.M.SE 1/4 NW 1/4 SEC 19, T 23 N, R 5 E; W.M.No.DATEDSNCHKAPPREVISIONSUBMITTED BY:DATE:REVIEWED BY:DATE:DATE:CONTRACT No.:FILENAME:SCALE:DRAWING No.:SHEET No.:REV:LINE IS 1" AT FULL SCALE DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:02/03/22 | 12:37 PM | LIN94S:\1924 - ST I-405 BRT\ROW\SHEET FILES\CUD5\BRT-405-RMP500.DWG BRT-405-RMP500FACILITY ID:PHASE 3 - 30% SUBMITTALI-405 BRTAE 0054-1702/11/22PRELIMINARY405FURTADO & ASSOCIATES, INC.Consulting Engineers901 5TH AVE., SUITE 2710SEATTLE, WA. 98164PHONE (206) 621-1218R. GORMAN02/11/22HORIZONTAL DATUM:BEARINGS ARE REFERENCED TO THE STATE PLANE GRID OF THE WASHINGTONCOORDINATE SYSTEM OF 1983, 2011 ADJUSTMENT (NAD83/2011) NORTH ZONE, AND THE UNITOF MEASURE IS THE U.S. SURVEY FOOT.PROJECT GRID COORDINATES BASED UPON WSDOT MONUMENTS GP17405-29 (POINT #300)AND GP17405-336 (POINT #301), OBSERVED BY CONVENTIONAL TOTAL STATIONOBSERVATIONS.SCALE FACTOR = 1, WHERE GRID = GROUND MEASUREMENTS FOR PROJECT LIMITS.VERTICAL DATUM:ELEVATIONS SHOWN HEREON ARE REFERENCED TO THE NORTH AMERICAN VERTICALDATUM OF 1988 (NAVD88), DERIVED FROM LEVEL TIES TO WSDOT MONUMENTS GP17405-29(POINT #300) AND GP17405-336 (POINT #301).HORIZONTAL CONTROL PRECISION:THE PRECISION OF THE HORIZONTAL CONTROL SURVEY PERFORMED FOR THIS NETWORKAND SHOWN HEREON HAS MET A MINIMUM OF 1:50,000, SECOND ORDER, CLASS I ASDEFINED BY THE FEDERAL GEODETIC CONTROL COMMITTEE AND PUBLISHED UNDER THETITLE, "STANDARDS AND SPECIFICATIONS FOR GEODETIC CONTROL NETWORKS",AUTHORED BY THE FEDERAL GEODETIC CONTROLCOMMITTEE IN SEPTEMBER 1984.VERTICAL CONTROL PRECISION:THE PRECISION OF THE VERTICAL CONTROL AND OF SUPPORTING VERTICAL GROUNDSURVEYS HAS MET THE MINIMUM SECOND ORDER, CLASS II LOOP CLOSURE, AS DEFINED BYTHE FEDERAL GEODETIC CONTROL COMMITTEE AND PUBLISHED UNDER THE TITLE"STANDARDS AND SPECIFICATIONS FOR GEODETIC CONTROL NETWORKS", AUTHORED BYTHE FEDERAL GEODETIC CONTROL COMMITTEE IN SEPTEMBER 1984.CITY OF RENTONMONUMENT NOTES:1.THE HORIZONTAL AND VERTICAL CONTROLMONUMENTS LISTED ON THIS DRAWING ARE FORTHE PURPOSE OF ESTABLISHING LINE ANDGRADE FOR THE CONSTRUCTION OF THE I-405BUS RAPID TRANSIT PROJECT. SECONDARYSURVEY CONTROL POINTS SHOULD BEESTABLISHED USING THESE MONUMENTS.2.THE MONUMENTS SHOWN ON THIS DRAWINGMAY HAVE BEEN UTILIZED TO DETERMINEEXISTING STREET R/W LINES AND PROPERTYLINES, OR MAY BE IN THE VICINITY OF THECONSTRUCTION ZONE AND THEREFORE INPOSSIBLE DANGER OF BEING DESTROYED ORMOVED. IN ACCORDANCE WITH RCW 58.09.130,ANY MONUMENT SHOWN HEREON AND ANYOTHER MONUMENTS THAT MAY BE FOUND NEARTHE CONSTRUCTION ZONE (SUCH AS PROPERTYCORNERS), EVEN IF NOT CURRENTLY KNOWNABOUT AND SHOWN HEREON, SHALL BEPRESERVED THROUGH THE PROCESS OF AN"APPLICATION FOR PERMIT TO REMOVE ORDESTROY A SURVEY MONUMENT" SUBMITTED TOTHE WASHINGTON STATE DEPARTMENT OFNATURAL RESOURCES.WSDOT LIMITED ACCESSPROPERTY LINELEGENDRIGHT-OF-WAY LINE301 (GP17405-336)174016.60130790.60119.18SURFACE MON300 (GP17405-29)173646.881297951.2347.67SURFACE MON GENERAL NOTES: 1.SEE SHEETS 405-CPP501 -502 FOR PAVING PLANS. 2.SEE SHEETS 405-CXP501 - 502 FOR DEMOLITION AND REMOVAL PLANS. TYPICAL SECTION NOTES: 2 HOT MIX ASPHALT 3 BASE COURSE 4 CEMENT CONCRETE CURB & GUTTER 5 CEMENT CONCRETE SIDEWALK 16 CEMENT CONCRETE EXTRUDED CURB STA. 17+81.50 TO STA. 18+51.44 RAINIER AVE S TYPICAL SECTION 405-C- RAINIER S CONSTRUCTION LINE 0.5' EX CURB VARIES 8.5'-12' EX SWLK & LSCP 12' TURN LANE 11' THRU LANE 11' THRU LANE 13' BUS ONLY LANE 0.5' CURB VARIES 9.5'-1.5' EX MEDIAN & LSCP 0.5' EX CURB 13.5' EX SWLK & LSCP 12' THRU LANE VARIES 2.4'-0' BUS ONLY LANE 11' THRU LANE VARIES 0'-12' THRU LANE 11' THRU LANE 16 VARIES 0' - 5.0' EX LSCP VARIES 0' - 4.0' EX LSCP STA. 14+07.84 TO STA. 16+29.22 RAINIER AVE S TYPICAL SECTION 405-C- RAINIER S CONSTRUCTION LINE 12' TURN LANE 11' THRU LANE 11' THRU LANE VARIES 0'-14' TURN LANE VARIES 2'-17.5' EX MEDIAN & LSCP 12' THRU LANE 11' THRU LANE VARIES 0'-12' THRU LANE 11' THRU LANE 4 5 8.0' LSCP VARIES 33'-40' SWLK BUILDING FACE 9.3' LSCP 8.0' SIDEWALK 5 4 4.5' LSCP VARIES LSCP 0.5' EX CURB VARIES 8.0' - 22.0' EX SWLK & LSCP VARIES 0' - 13.0' EX LSCP STA. 15+53.63 TO STA. 16+29.22 2 3 10" 9" CONTRACT UNIT DESCRIPTION 5 CIVIL ROADWAY TYPICAL SECTIONS RAINIER AVE S IN RENTON 405-CRY501 8 0 NTS No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/07/22 | 12:49 PM | DYDOPC:\BMS\WSP-PB-US-PW-02\WSP__PETER.DYDO\D0342984\BRT-405-CRY500.DWGBRT-405-CRY500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 GENERAL NOTES: 1.SEE SHEETS 405-CPP501 -502 FOR PAVING PLANS. 2.SEE SHEETS 405-CXP501 - 502 FOR DEMOLITION AND REMOVAL PLANS. TYPICAL SECTION NOTES: 1 2" HMA GRIND AND OVERLAY 2 HOT MIX ASPHALT 3 BASE COURSE 4 CEMENT CONCRETE CURB & GUTTER 17 RECONSTRUCT SIDEWALK AND PLANTER 16 CEMENT CONCRETE EXTRUDED CURB 5 CEMENT CONCRETE SIDEWALK EXISTING PLANTER VARIES 24.0' - 25.0' THRU LANE 2 3 4 0.5' EX CURB STA. 748+79.50 TO STA. 749+57.65 VARIES 24.0' - 27.0' TURN LANE VARIES 14.0'-5.0' EX SWLK 1 0.5' EX CURB VARIES 0'-30.0' PLANTER & SWLK 405-C-HARDIE SW CONSTRUCTION LINE HARDIE AVE SW TYPICAL SECTION 17 12" 8" VARIES 8.0'-16.0' SWLK 5 STA. 18+51.44 TO STA. 20+88.27 RAINIER AVE S TYPICAL SECTION 405-C-RAINIER S CONSTRUCTION LINE VARIES 13'-0' BUS LANE 0.5' CURB VARIES 0'-12.5' EX MEDIAN & LSCP 1.5' EX MEDIAN & LSCP 12' TURN LANE 0.5' EX CURB VARIES 8.5'-12' EX SWLK & LSCP 12' BAT LANE 11' THRU LANE 11' THRU LANE 11' THRU LANE 0.5' EX CURB 13.5' EX SWLK & LSCP 12' THRU LANE 11' THRU LANE 2 3 16 VARIES 0' - 5.0' EX LSCP VARIES 0' - 4.0' EX LSCP 10" 9" CONTRACT UNIT DESCRIPTION 5 CIVIL ROADWAY TYPICAL SECTIONS RAINIER AVE S AND HARDIE AVE SW IN RENTON 405-CRY502 9 0 NTS No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/07/22 | 12:49 PM | DYDOPC:\BMS\WSP-PB-US-PW-02\WSP__PETER.DYDO\D0342984\BRT-405-CRY500.DWGBRT-405-CRY500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 GENERAL NOTES: 1.SEE SHEETS 405-CPP501 -502 FOR PAVING PLANS. 2.SEE SHEETS 405-CXP501 - 502 FOR DEMOLITION AND REMOVAL PLANS. TYPICAL SECTION NOTES: 3 BASE COURSE 4 CEMENT CONCRETE CURB & GUTTER 14 MEDIAN TRANSIT ISLAND, SEE PAVING PLANS FOR FINISH 5 CEMENT CONCRETE SIDEWALK 6 CEMENT CONCRETE ROADWAY PAVEMENT 2 HOT MIX ASPHALT 15 DOWELED CURB VARIES 15.0' - 18.0' BUS LANE 405-C- CENTERISLAND N VARIES 15.0' - 18.0' BUS LANE VARIES 8.0' - 14.0' SWLK 0.5' CURB VARIES 0'-35' BUS PLATFORM VARIES 14.0' - 16.5' BUS LANE 405-C- CENTERISLAND S 0.5' CURB VARIES 0' - 5.5' LSCP 0.5' CURB TRANSIT CENTER - PLATFORM- TYPICAL SECTION 0.5' CURB BUILDING FACE VARIES 53' - 70' 6 3 15151515 55 14 6 3 405-C- CENTERISLAND N: STA. 10+00.00 TO 12+04.55 STA. 12+40.74 TO 13+33.92 17.0' SWLK 10.0' LSCP VARIES 14.0' - 16.5' BUS LANE 11" 6" 11" 6" 405-C- CENTERISLAND N 35' CONCRETE PAVEMENT 405-C- CENTERISLAND S 0.5' CURB TRANSIT CENTER - NO PLATFORM- TYPICAL SECTION 0.5' CURB BUILDING FACE VARIES 64' - 68' 6 3 1515 5 5 405-C- CENTERISLAND N: STA. 12+04.55 - 12+40.74 VARIES 8.0' - 14.0' SWLK 10.0' LSCP VARIES 20.5' - 22.0' SWLK VARIES 15.0' - 18.0' BUS LANE VARIES 15.0' - 18.0' BUS LANE VARIES 14.0' - 15.0' BUS LANE VARIES 14.0' - 15.0' BUS LANE 11" 6" VARIES LSCP VARIES* THRU LANE VARIES* THRU LANE 405-C- RAINIER - LAKE - DRWY 405 -C - GRADY- DRWY 0.5' CURB VARIES LSCP 0.5' CURB 3 2 4 GRADY, RAINIER AND LAKE DRIVEWAYS- TYPICAL SECTION 4 *: 405-C- RAINIER - LAKE - DRWY: 12.0' - 13.0' 405 -C - GRADY- DRWY: 12.0' 5" 8" CONTRACT UNIT DESCRIPTION 5 CIVIL ROADWAY TYPICAL SECTIONS SOUTH RENTON TC 405-CRY503 10 0 NTSDES DWN CHK APPNo.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/07/22 | 12:49 PM | DYDOPC:\BMS\WSP-PB-US-PW-02\WSP__PETER.DYDO\D0342984\BRT-405-CRY500.DWGBRT-405-CRY500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 GENERAL NOTES: 1.SEE SHEETS 405-CPP501 -502 FOR PAVING PLANS. 2.SEE SHEETS 405-CXP501 - 502 FOR DEMOLITION AND REMOVAL PLANS. TYPICAL SECTION NOTES: 1 2" HMA GRIND AND OVERLAY 2 HOT MIX ASPHALT 3 BASE COURSE 4 CEMENT CONCRETE CURB & GUTTER 5 CEMENT CONCRETE SIDEWALK 8.0' SIDEWALK VARIES 14.0' - 20.5' THRU LANE VARIES 16.0' - 28.0' THRU LANE STA. 10+00.00 TO STA. 11+89.62 LAKE AVE S TYPICAL SECTION VARIES EX SIDEWALK & LSCP 405-C-LAKE AVE S VARIES LAKE DRWV VARIES EX SIDEWALK & LSCP VARIES 14.5' - 28.0' THRU LANE STA. 11+50.41 TO STA. 11+84.83 STA. 11+27.89 TO STA. 11+84.83 2 3 5 2 3 4 VARIES 6.5' - 14.5' 2 3 WORK BY OTHERS 8.0' LSCP VARIES 8.0' - 13.0' 8" 5" 9" 10" 10" 9" 8.0' SIDEWALK VARIES 19.5' - 24.0' THRU LANE VARIES 15.0' - 23.5' THRU LANE STA. 13+81.47 TO STA. 14+63.38 LAKE AVE S TYPICAL SECTION VARIES EX SIDEWALK & LSCP 405-C-LAKE AVE S 4 4 5 23 VARIES 2.5' - 5.5' LSCP 9"10" VARIES TRANSIT CENTER 13.5' THRU LANE STA. 11+89.62 TO STA. 13+81.47 LAKE AVE S TYPICAL SECTION VARIES EX SIDEWALK & LSCP VARIES 14.0' - 25.5' THRU LANE VARIES 14.0' - 25.5' THRU LANE VARIES LSCP 405-C-LAKE AVE S STA. 11+84.83 TO STA. 12+80.70 4 2 3 23 10" 9" 9"10" CONTRACT UNIT DESCRIPTION 5 CIVIL ROADWAY TYPICAL SECTIONS LAKE AVE S 405-CRY504 11 0 NTSDES DWN CHK APPNo.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/07/22 | 12:49 PM | DYDOPC:\BMS\WSP-PB-US-PW-02\WSP__PETER.DYDO\D0342984\BRT-405-CRY500.DWGBRT-405-CRY500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 GENERAL NOTES: 1.SEE SHEETS 405-CPP501 -502 FOR PAVING PLANS. 2.SEE SHEETS 405-CXP501 - 502 FOR DEMOLITION AND REMOVAL PLANS. 3.PAVEMENT DEPTHS NOT SHOWN. TO BE DETERMINED IN FINAL DESIGN TYPICAL SECTION NOTES: 1 2" HMA GRIND AND OVERLAY 4 CEMENT CONCRETE CURB & GUTTER 5 CEMENT CONCRETE SIDEWALK 2 HOT MIX ASPHALT 3 BASE COURSE STA. 156+48.23 TO STA. 158+98.11 S GRADY WAY TYPICAL SECTION STA. 151+38.85 TO STA. 156+48.23 S GRADY WAY TYPICAL SECTION 405-C-GRADYW CONSTRUCTION LINE VARIES 0'-4.0' EX GORE VARIES 0'-11' TURN LANE 0.5' EX CURB 11' THRU LANE 11' THRU LANE VARIES 0'-11' TURN LANE 11' THRU LANE 11' THRU LANE 5 4 0.5' CURB 7.5' SWLK 8.0' LSCP 5.0' EX SWLK 405-C-GRADYW CONSTRUCTION LINE VARIES 0'-12' TURN LANE 0.5' EX CURB VARIES 0'-12' TURN LANE 12' THRU LANE 11' THRU LANE 12' THRU LANE 11' THRU LANE 5 4 0.5' CURB 8.0' SWLK 8.0' LSCP 5.0' EX SWLK 4.0' EX LSCP 2 3 2 3 No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/07/22 | 2:54 PM | DYDOPC:\BMS\WSP-PB-US-PW-02\WSP__PETER.DYDO\D0342984\BRT-405-CRY500.DWGBRT-405-CRY500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 CONTRACT UNIT DESCRIPTION 5 CIVIL ROADWAY TYPICAL SECTIONS S GRADY WAY 405-CRY505 12 0 NTS 02/11/2021 DES DWN CHK APP XXX X X X X XXX X CONC CONC CONC H H H H H H HSDSDSDSDSS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSDSS SDSDOE OE OE OE OE OE OE OE OEEE EE E E EE E E E W EWWWWWWWWWWWWWWWEEEEEG E E E E T T T T T E E E EEE EEE E E EEE E E E EEEEW CO WW WWWFO FOFOFOFO FO FO FOFO WW WW W TEEWWTTE E TTTTT EEEEEEE EE E T T T TTTT TTE E EEEEE E E E E G E E EE EE E E E E E E E E E E E E E E E E E E E EE E E E E E E E E E E EGGFOFOFOFOFO FO FO FO FO F OFO FO FO FO FO FOFO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FOFOFOFO FOFOFO W W W W W WW W W W WWWWWWWWWWWWSD SD SD SDSD W W WFO FOFOFO FOFOFOFO FO FO FO FO FOF O FOFO FO S D S D S D S D SD SDSD SDSD SDSDSDSDSDSDSDSDSDSD SDSDS D SDSDSD SD SD SD SD SD SD SD SD SD SD SD SDSDSD SD SD SD S S S S FOFOEEEEEEE EEEEE E FO FO FO FO FO FO FO FO FO FO FO FO FO FOFOFO FO X X X X X X X X X XXXXXXX X X X X X X X XXX XXX XX XXX X X X X X XX X X X X X X X X X X X X XXXXXX CONC XXXXX/ /// /// /////////// ////////////////////// / //////// /////////////////////// / / //////// /////////////////////////////////////////////////////////////////////OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE OE OE OE OE OE OE OE OE OE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE OE OE OE OE OE OE OE OE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE////////////////// //////////////////////////////////////////////////////////////////////////////////////////////////////////////// ///////////// / ///////////////// / / OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE SDSSSSSS GGFO FO FO FO EEEEEEEEEEEEE E E E E E E E OEOEOEOEOEOEFO FO FO FOFOFOFOFOFO FOFOFOFOFOFOFOWWWSSSSSSSSSSSSSSSSSSFOSSSSSSSSEEEE WWE E E E TT T T T T T T T T T GGGGG G G GGGGGG G GGGE E EEE E E EEE E W W W W W G G EEW E EE EEEE E E EEWWWW E EE E EE E CCCCCFOFOFOFOFOFOFOFOFOFOTTTTTTEFOFOET T TEEGGFOFOFOC EFOG EBOREHOLE GA-10 EL=26.31 BOREHOLE SB-1 EL=27.17 BOREHOLE GA-14 EL=26.36 BOREHOLE P-14 EL=25.43 BOREHOLE GA-1 EL=25.09 BOREHOLE GA-2 EL=25.98 BOREHOLE RW10 EL=25.30 BOREHOLE GA-3 EL=25.97 BOREHOLE GA-4 EL=26.06 BOREHOLE SH-5 EL=26.22 BOREHOLE GA-8 EL=26.69 BOREHOLE GA-5 EL=27.71 BOREHOLE GA-7 EL=27.67 BOREHOLE GA-6 EL=27.90 BOREHOLE SB-2 EL=27.29 BOREHOLE GA12 EL=26.45 BOREHOLE GA-13 EL=26.06 BOREHOLE P-15 EL=25.66 FO FO FO FO E E E E E E E E FO FO FO FO FO FO FO FO 405-C-G r a d y W405-C-RainierS40 5 - C - H a r d i e S W 1 15 15 15 15 15 15 PROPERTY LINE, TYP 43 43 42 42 42 42 42 42 12 12 1 3 1 3 1 3 3 3 1 2 2 3 2 12+0014+0016+0018+0075 0 + 0 0 75 0 + 0 0 152+00 154+00 156+00 158+00 160+00 11+47 10+00 19+ 2 6 10+00 12+ 0 0 14+0 0 16+00 18+ 0 0 17+65 10+00 12+ 0 0 14+00 16+00 9+ 5 1 10+ 0 0 12+ 0 0 14+00 16+00 18+00 18+30 14+70 9+75 10+0012+0014+00 S GRAD Y W A YRAINIER AVE SLAKE AVE SSTA 158+98.11, 15.93' LT END STA 158+98.15, 27.14' LT STA 158+55.16, 42.55' LT END 405 - C - C e n t e r I s l a n d N 405-C-CenterIslandN 40 5 - C - G r a d y - D r w y 405 - C - R a i n i e r - L a k e - D r w y 3 STA 159+15.41, 63.75' LT 44 45 46 STA 151+38.85, 17.20' LT END STA 151+38.88, 28.76' LT END STA 151+38.89, 46.58' LT END 47 47 STA 13+48.11, 33.49' LT 3 STA 14+58.96, 43.74' LT STA 13+97.67, 37.91' LT STA 14+53.90, 34.52' LT BEGIN STA 14+58.96, 43.74' LTSTA 14+58.96, 43.74' LT END STA 14+72.06, 22.61' RT STA 13+81.47, 14.79' RT BEGIN STA 12+79.06, 14.68' RT END STA 12+63.06, 14.77' RT BEGIN STA 13+81.46, 0.00' RT END STA 13+81.45, 13.79' RT STA 11+78.14, 12.95' RT STA 11+27.92, 7.87' RT BEGIN STA 11+27.98, 16.03' RT END 42 1AeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinLEGEND: HMA PAVEMENT REMOVAL CLEARING AND GRUBBING SAWCUT LINE CLEARING AND GRUBBING LIMITS CURB REMOVAL CONCRETE SIDEWALK REMOVAL STRUCTURE REMOVAL HMA GRINDING GRAVEL REMOVALAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinDEMOLITION AND REMOVAL NOTES: 1 REMOVE EXISTING CEMENT CONCRETE SIDEWALK 2 REMOVE EXISTING CONCRETE CURB 3 REMOVE EXISTING CONCRETE CURB AND GUTTER 12 REMOVE EXISTING ASPHALT PAVEMENT 16 HMA GRIND PER TYPICAL SECTION SHEETS. SEE SHEETS 405-CRY501 - 505. 15 CLEAR AND GRUB EXISTING VEGETATION 42 REMOVE EXISTING STRUCTURE 43 REMOVE GRAVEL 46 REMOVE EXISTING GATE 45 REMOVE EXISTING BOLLARD 44 REMOVE EXISTING CONCRETE FOUNDATION 47 REMOVE EXISTING ASPHALT PAVEMENT. SEE CITY OF RENTON STD PLAN - 110 FOR PAVEMENT RESTORATION REQUIREMENTS. GENERAL NOTES: 1.SEE SHEETS 405-UCP501 - 502 FOR UTILITY RELOCATIONS. 2.SEE SHEETS 405-CDP501 - 502 FOR DRAINAGE PLANS. 3.SEE SHEETS 405-CPP501 - 502 FOR PAVING PLANS. 4.SEE SHEETS 405-CRY501 - 505 FOR TYPICAL ROADWAY SECTIONS. 5.SEE SHEETS 405-ELP501 - 502 FOR ILLUMINATION PLANS. 6.SEE SHEETS 405-LHP501 FOR HARDSCAPE PLANS. 7.EXISTING FACILITIES TO BE PROTECTED-IN-PLACE UNLESS OTHERWISE NOTED. 8.DEMOLITION OF EXISTING ASPHALT PAVEMENT, CONCRETE PAVEMENT, SIDEWALK, CURB AND GUTTER, DRIVEWAY, MEDIAN, CROSS GUTTER SHALL BE FULL DEPTH REMOVALS, AND INCLUDE BASE COURSE, IF PRESENT. N SCALE IN FEET 0 4020 8040 (1" = 40') CONTRACT UNIT DESCRIPTION 5 CIVIL DEMOLITION AND REMOVAL PLAN SOUTH RENTON TC 405-CXP501 13 0 1" = 40' No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/04/22 | 2:51 PM | USRS670585C:\BMS\WSP-PB-US-PW-02\WSP__RONALD.SMITH2\D0342984\BRT-405-CXP500.DWGBRT-405-CXP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 SEE SHEET 405-CXP502 FOR REMOVALS ALONG RAINIER AVE S X CON C UT H HHH H / / ///////// SD SD SD SD SD SDS S S S S S S S S S S S S SSSSS T T E F O FO F O E CO EE E EE EE EE EEWE W W W W W W W W W W W W W W W EE E E E FO FO W WGGE EGFOFO FO E E EGG G G G G G G E E E E E E E E E E FO T T T FO FO FO FO FO FO FO E E E E E E E E E E E E FO FO FO E E TEEEW W W W W W WGGG G GGGG C O WWFO FO FOFOFOFOFOFOWW W WWE E WWTTE EEE EE EEEE E T TTTT T T T T EEEEGEEE E E E E E E E E E E E E E E E E E E E EE E E EE EEEE E E EG G G G G G G GG GGG G FO FO FO F O F O F O FO FO FO FO FOFOFOFOFOFO FO FOFOFO FO FO FO FO FOFOFOFO FO FO FO FOFO FO FO FOFOFOFO FOFOFOFO FOFO FO FOFOFOW W WW W W W W WWWSDSDSDSDSDSDSDSD SD SDFO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FOFOFO FO FO FOFO FO FO FO FO FO SDSD SD SD SD SD SD SD SD SD SD SD SDSD SD SD SD SD SD SD SD SD SDSDSD SSSSSSSSSSSSSSSSSSS S E EE E E E E E E E E EF O FO FOFOFOFOFOFOE E E FO FOFOFOFOFOFO FO FOFOX XX XXXXX X X XXXXXXX XXXXXXXXXCON C ////////////////// / ///// / / / / / / / / ///////// /// ///////// / / /// / /// / / / / / / /////////////// / / / / / / / //////// ////////// // / / / / / / / / / / / ////// / / / / / // / / / //////OE OEOE SDE E ESSSSSSSSSSSSSS SSSSSSSSSSSSSSFOFOFOFOE E E E EEEEEEEEEE E E ///////////// / / / / / / /// / //FOFOFOFOFOFOFOFOFOFOEEE GFO FO FOFOFOFOFOFO FO FO FO FO FOFOFOFOFOFOFOFOSS SS SS SS SS W W W WWWWWWWSD SD F O FOFOFOFOFOFOSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SS SS SS WWSD SD SD SD SDSDSSSSSSSSSSESS SS SS EEEET TTT GGGGGGGG GG EEE E E E EEEEWWWWWGGGE E EE E E E EEEEW WWWEEE EE E E C C C C C FO FO FO FO FO FO FO FO FO FO T T T T T TEFOFOETT TEEG G FOFOFO CCEFO GE BOREHO L E S B - 1EL = 2 7 . 1 7 BOREHO L EGA - 1 4 E L = 2 6 . 3 6 BO R EHO L E P - 1 4 E L = 2 5 . 4 3 BOR E HO LE P - 1 2 E L = 2 5 . 1 4 BOREHO L EGA - 1 E L = 2 5 . 0 9 BO R EHO LEGA - 2 E L = 2 5 . 9 8 BORE HO L ERW1 0EL = 2 5 . 3 0 BOREHO L E G A - 3EL = 2 5 . 9 7 BO R EHO L E SB - 2 E L = 2 7 . 2 9BOREHO L E G A 1 2EL = 2 6 . 4 5 BOREHO L EGA - 1 3 E L = 2 6 . 0 6 BOREHO L E P - 1 5 E L = 2 5 . 6 6 4 0 5 -C -R a i n i e r S 405-C- H ar di e S W 405-C -SW7THST 1 15 15 15 15 PROPERTY LINE, TYP STA 748+79.37, 24.16' RT END STA 20+94.76, 12.95' LT END STA 17+52.04, 44.57' LT BEGIN STA 748+79.46, 0.00' LT END STA 17+73.34, 45.15' LT END STA 17+71.49, 50.62' LT END STA 17+61.55, 50.38' LT BEGIN 16 15 3 1 3 1 2 3 2 2 1 STA 15+95.34, 58.11' LT END STA 15+85.51, 66.27' LT STA 15+75.63, 62.20' LT STA 15+74.71, 40.96' LT BEGIN STA 15+56.90, 39.48' LT BEGIN STA 15+53.63, 38.88' LT BEGIN STA 749+57.92, 51.29' LT BEGIN STA 748+79.56, 24.67' LT END STA 749+57.64, 0.00' RT BEGIN STA 19+90.59, 1.53' LT STA 17+88.05, 12.43' RT END STA 16+29.22, 13.43' RT BEGIN STA 16+28.98, 3.99' LT BEGIN STA 15+74.88, 44.72' LT 12 2 2 3 15 STA 15+53.66, 37.96' LT BEGIN STA 16+21.71, 40.57' LT BEGIN STA 749+57.38, 10.68' RT BEGIN STA 17+71.12, 59.23' LT END STA 17+61.27, 58.88' LT BEGIN 12+0 0 14+00 16+00 18+00 20+00 22+00 747+ 0 0 748+ 0 0 750+00750+00248+0010+00 12+0010+00 12+009+5110+0012+00HARDI E A V E S W RAINIER A V E S SW 7TH ST SEE SHEET 405-CXP501 FOR TRANSIT CENTER REMOVALS STA 12+32.76, 63.14' RT BEGIN STA 12+75.81, 63.30' RT END STA 12+76.23, 49.50' RT END STA 12+32.69, 49.49' RT BEGIN STA 14+07.84, 49.45' RT BEGIN STA 17+07.06, 62.97' RT BEGIN STA 14+48.04, 63.18' RT BEGIN STA 12+70.39, 63.04' RT BEGIN STA 12+39.30, 63.20' RT END STA 14+14.83, 63.14' RT END STA 16+73.18, 63.15' RT END STA 17+85.11, 49.66' RT END STA 17+86.74, 62.07' RT END STA 17+86.62, 61.58' RT END405-C-CenterIslandN405-C-Rainier-Lake-Drwy15 15 PROPERTY LINE, TYP 1 2 3 48 LEGEND: HMA PAVEMENT REMOVAL CLEARING AND GRUBBING HMA GRINDING SAWCUT LINE CLEARING AND GRUBBING LIMITS CURB REMOVAL CONCRETE SIDEWALK REMOVAL STRUCTURE REMOVAL DEMOLITION AND REMOVAL NOTES: 1 REMOVE EXISTING CEMENT CONCRETE SIDEWALK 2 REMOVE EXISTING CONCRETE CURB 3 REMOVE EXISTING CONCRETE CURB AND GUTTER 12 REMOVE EXISTING ASPHALT PAVEMENT 16 HMA GRIND PER TYPICAL SECTION SHEETS. SEE SHEETS 405-CRY501 - 505. 15 CLEAR AND GRUB EXISTING VEGETATION 48 REMOVE EXISTING HARDSCAPE GENERAL NOTES: 1.SEE SHEETS 405-UCP501 - 502 FOR UTILITY RELOCATIONS. 2.SEE SHEETS 405-CDP501 - 502 FOR DRAINAGE PLANS. 3.SEE SHEETS 405-CPP501 - 502 FOR PAVING PLANS. 4.SEE SHEETS 405-CRY501 - 505 FOR TYPICAL ROADWAY SECTIONS. 5.SEE SHEETS 405-ELP501 - 502 FOR ILLUMINATION PLANS. 6.SEE SHEETS 405-LHP501 FOR HARDSCAPE PLANS. 7.EXISTING FACILITIES TO BE PROTECTED-IN-PLACE UNLESS OTHERWISE NOTED. 8.DEMOLITION OF EXISTING ASPHALT PAVEMENT, CONCRETE PAVEMENT, SIDEWALK, CURB AND GUTTER, DRIVEWAY, MEDIAN, CROSS GUTTER SHALL BE FULL DEPTH REMOVALS, AND INCLUDE BASE COURSE, IF PRESENT. CONTRACT UNIT DESCRIPTION 5 CIVIL DEMOLITION AND REMOVAL PLAN RAINIER AVE S 405-CXP502 14 0 1" = 40' No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/04/22 | 2:57 PM | USRS670585C:\BMS\WSP-PB-US-PW-02\WSP__RONALD.SMITH2\D0342984\BRT-405-CXP500.DWGBRT-405-CXP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 N SCALE IN FEET 0 4020 8040 (1" = 40') XXX X X X X XXX X H H H H HEE EE E E EE E 2VLTS T X X X X X X X X X XXXXXXX X X X X X X X XXX XXX XX XXX X X X X X XX X X X X X X X X X X X X XXXXXXXXXXX/ /// /// /////////// /////////////// /////// / // ///// / /////////////////////// / / //////// /////////////////////////////////////////////////////////////////////////////////////// //////////////////////////////////////////////////////////////////////////////////////////////////////////////// ///////////// ////////////////// / /CCCCCC BOREHOLE GA-10 EL=26.31 BOREHOLE SB-1 EL=27.17 BOREHOLE GA-14 EL=26.36 BOREHOLE EL=25.43 BOREHOLE GA-1 EL=25.09 BOREHOLE GA-2 EL=25.98 BOREHOLE RW10 EL=25.30 BOREHOLE GA-3 EL=25.97 BOREHOLE GA-4 EL=26.06 BOREHOLE SH-5 EL=26.22 BOREHOLE GA-8 EL=26.69 BOREHOLE GA-5 EL=27.71 BOREHOLE GA-7 EL=27.67 BOREHOLE GA-6 EL=27.90 BOREHOLE SB-2 EL=27.29 BOREHOLE GA12 EL=26.45 BOREHOLE GA-13 EL=26.06 BOREHOLE P-15 EL=25.66 S GRAD Y W A Y LAKE AVE SRAINIER AVE S405-C-G r a d y W 405 - C - R a i n i e r - L a k e - D r w y 405-C-CenterIslandN SEE 405-CAP502 FOR ROADWAY ALIGNMENT INFORMATION PROPERTY LINE, TYP 152+00 154+00 156+00 158+00 160+00 161+00 10+08.61, 0.00' 11+47 10+00 19+ 2 6 10+00 12+ 0 0 14+0 0 16+00 18+ 0 0 17+65 10+00 12+0 0 14+00 16+00 9+ 5 1 10+ 0 0 12+ 0 0 14+00 16+00 18+00 18+30 14+70 9+75 10+0012+0014+00 405-C-Grady-Drwy 405-C-CenterIslandN 405-C-CenterIslandS 405-C-LakeAve-SLEGEND:LEGEND: EXISTING PARCEL LINE N SCALE IN FEET 0 4020 8040 (1" = 40') CONTRACT UNIT DESCRIPTION 5 CIVIL ALIGNMENT PLAN AND DATA SOUTH RENTON TC 405-CAP501 15 0 1" = 40' No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/03/22 | 4:34 PM | DYDOPC:\BMS\WSP-PB-US-PW-02\WSP__PETER.DYDO\D0342984\BRT-405-CAP500.DWGBRT-405-CAP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELI MI N A RY 405 R. GORMAN 02/11/2022 ALIGNMENT CONTROL - 405-C-CENTERISLANDN LINE STATION NORTHING EASTING DESCRIPTION BEARING LENGTH RADIUS 10+00.00 175469.62 1298163.69 BEGIN POINT S74° 02' 43"E DELTA 10+42.88 175457.84 1298204.91 PC 10+61.59 175452.68 1298222.94 PI 215.00'37.41'9°58'12" 17+64.99 175339.92 1298902.67 END POINT 10+80.29 175444.48 1298239.81 PT S64° 04' 31"E 11+89.14 175396.89 1298337.71 PC 11+97.93 175393.05 1298345.62 PI 200.00'17.58'5°02'10" 12+06.72 175389.91 1298353.84 PT S69° 06' 41"E 12+44.60 175376.40 1298389.23 12+49.05 175374.82 1298393.38 200.00'8.90'2°32'58" 12+53.50 175373.05 1298397.47 S66° 33' 43"E PC PI 13+19.38 175346.85 1298457.91 13+34.65 175340.68 1298472.11 75.00'30.55'23°20'09" 13+49.92 175340.66 1298487.61 S89° 53' 52"E PT PC PI PT ALIGNMENT CONTROL - 405-C-GRADY-DRWY LINE STATION NORTHING EASTING DESCRIPTION BEARING LENGTH RADIUS BEGIN POINT S1° 19' 15"W DELTA PC PI 30.00'30.51'58°16'32" PT S56° 57' 17"E PC PI 40.00'30.92'44°17'06" PT S12° 40' 11"E END POINT 10+55.63 175,004.66 1,298,459.71 10+95.47 174,982.94 1,298,493.11 11+10.93 174,974.06 1,298,506.75 11+47.11 174,937.96 1,298,514.87 11+26.38 174,958.18 1,298,510.32 10+00.00 175055.61 1298446.66 10+25.11 175,030.50 1,298,446.08 10+40.37 175,013.78 1,298,445.70 ALIGNMENT CONTROL - 405-C-CENTERISLANDS LINE STATION NORTHING EASTING DESCRIPTION BEARING LENGTH RADIUS 9+51.35 175446.52 1298093.79 BEGIN POINT S61° 42' 29"E DELTA 48.65'10+00.00 175423.46 1298136.63 PI S64° 04' 41"E 13+14.22 175286.10 1298419.24 PC 18+29.77 175274.07 1298933.12 END POINT 13+38.89 175275.13 1298441.80 PI 109.57'49.33' 25°47'55" 13+63.55 175275.08 1298466.90 PT S89° 52' 37"E ALIGNMENT CONTROL - 405-C-RAINIER-LAKE-DRWY LINE STATION NORTHING EASTING DESCRIPTION BEARING LENGTH RADIUS BEGIN POINT S64° 04' 31"E DELTA PC PI 112.00'50.48'25°49'26" PT S89° 53' 57"E PC PI 87.00'54.83'36°06'40" PT N53° 59' 23"E END POINT 14+38.29 175067.57 1298465.49 16+69.56 175067.17 1298696.76 16+96.98 175067.12 1298725.12 19+26.03 175149.86 1298918.37 17+24.40 175083.79 1298748.06 10+00.00 175248.39 1298067.93 13+87.81 175078.85 1298416.72 14+13.05 175067.62 1298439.81 PC PI 28.00'30.71'62°50'33" PT S63° 10' 03"E 18+59.95 175163.49 1298857.71 18+75.31 175173.54 1298871.55 18+90.66 175165.82 1298886.81 ALIGNMENT CONTROL - 405-C-LAKEAVE-S LINE STATION NORTHING EASTING DESCRIPTION BEARING LENGTH RADIUS BEGIN POINT N4° 30' 51"E DELTA PC PI 111.04'74.25'38°18'44" PT N41° 44' 21"E PC PI 140.00'102.76'42°03'12" PT N0° 18' 51"W 10+82.97 175080.40 1298862.49 11+36.19 175120.11 1298897.91 11+87.57 175160.26 1298933.74 12+38.94 175214.08 1298933.44 9+74.53 174979.07 1298831.71 10+08.72 175013.15 1298834.40 10+45.85 175051.65 1298836.76 PC PI 50.00'73.53'84°15'27" END POINT N83° 56' 36"E 13+96.47 175371.60 1298932.58 14+33.24 175416.83 1298932.33 14+70.00 175421.60 1298977.30 ALIGNMENT CONTROL - 405-C-GRADYW LINE STATION NORTHING EASTING DESCRIPTION BEARING LENGTH RADIUS 147+00.00 174725.04 1297688.70 BEGIN POINT N77° 28' 11"E DELTA 161+00.00 175028.78 1299055.36 END POINT 1400.00' X X UT H HH H H / / ///////// T T E F O FO F OICVICV ICVICVICVICVICVICVICV ICV E CO EE E EE E E E WE E EE EE X XX XXXXX X X XXXXXXX XXXXXXXXX////////////////// / ///// / / / / / / / / ///////// //////////// / / /// / /// / / / / / / /////////////// / / / / / / / //////// //////////// / / / / / / / / / / / ////// / / / / / //// / ////// //////// ///// / / /// / //SSSSC C C C CCC BOREHO L E S B - 1 E L = 2 7 . 1 7 BO R EHO L EGA - 1 4 E L = 2 6 . 3 6 BO R EHO L E P - 1 4 E L = 2 5 . 4 3 B OR E H O L E P - 1 2 E L = 2 5 . 1 4 BOREHO L EGA - 1 E L = 2 5 . 0 9 B OR EHO LEGA - 2 E L = 2 5 . 9 8 BOREHO L ERW1 0EL = 2 5 . 3 0 BOREHO L E G A - 3EL = 2 5 . 9 7 BO R EHO L E SB - 2 E L = 2 7 . 2 9BOREHO L E G A 1 2EL = 2 6 . 4 5 BOREHO L E G A - 1 3 E L = 2 6 . 0 6 BORE HO L E P - 1 5 E L = 2 5 . 6 6 RAINIER AVE S SW 7TH ST PROPERTY LINE, TYP HARDI E A V E S W 405-C - H ar di e S W 405-C-R a i n i e r S SEE 405-CAP501 FOR TRANSIT CENTER ALIGNMENT INFORMATION 10+09 12+0 0 14+00 16+00 18+00 20+00 22+00 747+ 0 0 748+ 0 0 750+00750+009+5110+0012+00S G R AD Y W A Y LEGEND:LEGEND: EXISTING PARCEL LINE CONTRACT UNIT DESCRIPTION 5 CIVIL ALIGNMENT PLAN AND DATA RAINIER AVE S 405-CAP502 16 0 1" = 40' No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/03/22 | 4:34 PM | DYDOPC:\BMS\WSP-PB-US-PW-02\WSP__PETER.DYDO\D0342984\BRT-405-CAP500.DWGBRT-405-CAP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 N SCALE IN FEET 0 4020 8040 (1" = 40') ALIGNMENT CONTROL - 405-C-RAINIER S STATION NORTHING EASTING DESCRIPTION BEARING LENGTH RADIUS DELTA 10+08.61 174790.12 1297981.55 BEGIN POINT N1° 08' 06"E 12+56.31 175037.77 1297986.46 PC 15+73.24 175368.42 1297993.01 PI 900.00'633.85'40°21'09" 27+00.00 176222.81 1298748.57 END POINT N41° 29' 14"E18+90.16 175368.42 1297993.01 PT ALIGNMENT CONTROL - 405-C-HARDIESW LINE STATION NORTHING EASTING DESCRIPTION BEARING LENGTH RADIUS 747+00.00 175714.88 1298018.45 BEGIN POINT S1° 12' 21"W DELTA 748+81.76 175533.16 1298014.63 PC 749+00.64 175512.21 1298014.19 PI 35.00'37.77'61°49'25" 750+00.00 175462.44 1298102.57 END POINT S60° 37' 04"E749+19.52 175501.93 1298032.45 PT H EE E T C BOREHOLE RW10 EL=25.30 BOREHOL P-15 EL=25.66 30.0'8.5'S GRAD Y W A Y LAKE AVE SRAINIER AVE S405-C-Gr a d y W 40 5 - C - H a r d i e S W R60.0' STA 151+39.19, 36.76' LT R17.5'R17.5'R100.0'R100.0' STA 10+16.02, 13.94' RT STA 10+67.46, 12.69' RT STA 10+89.58, 10.33' RT STA 11+19.80, 12.00' RT STA 10+61.20, 10.92' LT STA 10+26.43, 11.57' LT STA 155+20.69, 28.11' LT STA 10+95.07, 12.19' LT STA 155+85.67, 28.19' LT STA 11+26.53, 12.00' LT STA 11+23.37, 12.00' LT STA 159+15.41, 63.75' LT 405 - C - R a i n i e r - L a k e - D r w y 405-C-Grady-Drwy STA 13+38.87, 16.00' RT STA 10+42.82, 15.00' RT STA 10+80.29, 15.00' RT STA 10+42.81, 15.00' LT STA 10+80.29, 15.00' LT STA 11+89.67, 15.00' RT STA 11+98.64, 14.79' LT STA 12+49.42, 18.05' LT STA 12+59.53, 17.86' RT STA 13+18.96, 17.86' RT STA 13+26.91, 17.71' LT STA 13+57.47, 15.00' LT STA 17+09.16, 14.81' RT STA 17+50.73, 15.00' LT 10.0' 405-C-CenterIslandN16+0018+0075 0 + 0 0 75 0 + 0 0 152+00 154+00 156+00 158+00 160+00 161+00 11+47 10+00 19+ 2 6 10+00 12+ 0 0 14+0 0 16+00 18+0 0 17+65 10+00 12+ 0 0 14+00 16+00 9+5 1 10+ 0 0 12+ 0 0 14+00 16+00 18+00 18+30 14+70 9+75 10+0012+0014+00 3 3 3 3 3 38 3 3 3 3 3 3 3 3 10 10 10 28 26 26 2 2 9 9 9 29 29 29 2 37 38 38 38 1 40 40 39 39 40 43 37 37 1 SEE SHEET 405-CPP502 FOR PAVING IMPROVEMENTS ALONG RAINIER AVE S 29 29 29 29 29 41 41 2 2 2 R 2 5 . 0 ' R18. 0' R25.0' R 2 4 . 0 ' R 4 0 . 0 ' R80.0' R 5 0 . 0 ' R25.0'R200.0'R230.0'R95.0'R15.0' R24.0'R20.0 'R25.0' R25.0' R55.0' R 2 0 . 0 'R20.0'R 2 5 . 0 ' R24. 0' R48.0'8.5'7.5' STA 11+26.45, 12.00' RT 8.5'7.5'8.5'7.5'8.0'8.5' 8.5' 8.0' 8. 0 '9.5'8.0'15.5' 8.0' 8.5' 6 . 0 '10.0'8.5'14.0'8.5'10.0'12.0'10. 0 ' 19. 5 ' STA 10+15.82, 15.01' RT 8.5' 8.5' 33. 0 ' 40. 0 '5.5'8.0'3.5'28.0'30.0'26.0'24.0'30.0'28.0'36.0'36.0 '30.0'33.0'30.0'30.0'23.0' 2 2 . 0 ' STA 13+57.43, 43.14' LT STA 14+51.11, 22.00' LT STA 16+69.56, 22.00' LT STA 13+95.43, 13.29' RT STA 16+10.46, 12.00' RT STA 16+69.56, 12.00' RT STA 17+24.40, 12.00' RT STA 18+58.65, 12.00' RT STA 18+59.77, 12.00' LT STA 13+15.42, 13.00' RT STA 18+29.57, 44.00' LT STA 15+85.46, 37.00' RT STA 15+85.46, 67.00' RT STA 14+52.52, 12.00' RT STA 15+61.46, 67.00' RT STA 15+35.46, 12.00' RT STA 15+61.46, 37.00' RT STA 17+39.69, 44.00' LT STA 16+53.44, 100.67' LT STA 13+32.92, 43.14' LT STA 13+32.92, 77.52' LT STA 13+36.38, 93.80' LT STA 13+50.27, 124.99' LT STA 13+51.87, 137.16' LT STA 13+15.42, 13.00' LT STA 17+24.40, 12.00' LT STA 16+69.56, 12.00' LT STA 14+40.59, 12.00' LT STA 18+87.89, 11.85' LT STA 17+24.40, 22.00' LT 2 2 . 0 ' 24.0'30.0'33.0'40.5'44.5 ' 9 34.0' 29.0'24.0'26.0'24.0'24.0'24.0' 2 4 . 0 '25.5'18. 5 '22.0'35. 5 ' 22. 0 '18.5'17.0'20.5'22.0'11.0'11.0' STA 158+33.55, 28.22' LT STA 151+38.85, 17.20' LT STA 158+98.11, 15.93' LT STA 158+98.15, 27.09' LT STA 151+38.85, 28.15' LT 44 44 R37.0' WORK BY OTHERS 40 STA 13+90.15, 12.98' LT R35.0'R65.0' R 5 0 . 0 ' STA 18+42.35, 22.00' LT STA 18+67.06, 49.39' LT 1 R35.0' STA 17+57.69, 15.99' LT STA 17+58.57, 80.80' RT 9.5'14.0' 13.5'R4.5'R4.5'R1 0 . 0 ' R26. 0' R2 0 . 0 'R99 . 0 ' R12.5' R5.0'R60.0'R65.0 ' R40.0'R35.0' STA 14+58.98, 43.72' LT STA 14+57.04, 35.05' LT STA 14+72.07, 23.61' RT STA 12+59.58, 14.15' LT STA 12+13.92, 16.32' LT STA 11+27.89, 16.02' RT STA 11+33.77, 17.80' LT STA 13+81.47, 14.79' RT 8. 5 ' 3 4 . 0 'R100.0'102642 STA 12+26.71, 16.32' LT 405-C-CenterIslandS STA 12+64.94, 16.13' LT STA 13+28.21, 18.03' LT STA 13+59.24, 15.71' LT STA 17+43.39, 14.95' LT STA 17+13.63, 47.07' RT STA 16+57.51, 15.10' RT STA 16+44.24, 15.13' RT STA 15+96.94, 49.26' RT STA 11+78.14, 12.95' RT GENERAL NOTES: 1.SEE SHEETS 405-CRY501 - 505 FOR TYPICAL ROADWAY SECTIONS. 2.SEE SHEETS 405-CAV501 - 504 FOR ROADWAY AND DRIVEWAY PLAN AND PROFILES. 3.SEE SHEETS 405-CXP501 - 502 FOR DEMOLITION AND REMOVAL PLANS. 4.SEE SHEETS 405-CDP501 - 502 FOR DRAINAGE PLANS. 5.SEE SHEETS 405-CMP501 - 502 AND 405-TNP501 - 502 FOR PAVEMENT MARKING AND SIGNAGE PLANS. 6.SEE SHEETS 405-UCP501 - 502 FOR UTILITY PLANS. 7.EXISTING FACILITIES TO BE PROTECTED-IN-PLACE UNLESS OTHERWISE NOTED. 8.FOR ITEMS NOT SHOWN, SEE DRAINAGE, TRAFFIC, AND UTILITY SHEETS. 9.SEE SHEET 405-LHP501 FOR HARDSCAPE PLANS. 10.SEE SHEETS 405-CAP501 - 502 FOR ALIGNMENT PLANS. 11.AT PROPOSED CURBS, STATION AND OFFSET CALLOUTS ARE PROVIDED FOR ALL GEOMETRY POINTS, INCLUDING BEGINNING AND END. RADIUS AND STATION AND OFFSET CALLOUTS ARE AT THE FACE OF CURB. 12.DESIGN ELEMENTS REFERENCE STANDARD PLANS IN ACCORDANCE WITH THE JURISDICTION IT FALLS WITHIN. FOR LINEAR ELEMENTS CROSSING PROPERTY LINES, SPLIT SHALL OCCUR AT GEOMETRY POINT CLOSEST TO THE PROPERTY LINE. CONSTRUCTION NOTES: 3 INSTALL CEMENT CONCRETE ADA PERPENDICULAR CURB RAMP PER KCM STD PLAN D110. GRADING DETAIL TO BE PROVIDED AT 90%. 10 INSTALL CEMENT CONCRETE PAVEMENT PER KCM STD PLAN D108A 29 INSTALL INTEGRAL DOWELED CURB PER KCM STD PLAN D109 26 INSTALL CEMENT CONCRETE SIDEWALK/LANDING PAD PER KCM STD PLAN D108 28 INSTALL CEMENT CONCRETE PARALLEL CURB RAMP PER KCM STD PLAN D110 9 INSTALL HMA ROADWAY PAVEMENT PER TYPICAL SECTIONS SHEETS 37 INSTALL CEMENT CONCRETE PARALLEL CURB RAMP PER WSDOT STD PLAN F-40.12-03 38 INSTALL CEMENT CONCRETE ADA PERPENDICULAR CURB RAMP PER WSDOT STD PLAN F-40.15-04. GRADING DETAIL TO BE PROVIDED AT 90%. 39 INSTALL CEMENT CONCRETE CURB AND GUTTER PER CITY OF RENTON STD PLAN 101 40 INSTALL CEMENT CONCRETE CURB AND GUTTER PER KCM STD PLAN D109 41 INSTALL CEMENT CONCRETE SIDEWALK PER CITY OF RENTON STD PLAN 102 1 INSTALL CEMENT CONCRETE CURB AND GUTTER PER WSDOT STD PLAN F-10.12-04 2 INSTALL CEMENT CONCRETE SIDEWALK PER WSDOT STD PLAN F-30.10-04 42 INSTALL CHAIN LINK FENCE PER WSDOT STD PLAN L-20.10-03 IN CONFORMANCE WITH ST STD SPECIFICATION SECTION 32 31 13 43 INSTALL CEMENT CONCRETE CURB PER WSDOT STD PLAN F-10.12-04 44 INSTALL HMA PAVEMENT PER CITY OF RENTON STD PLAN - 110 CEMENT CONCRETE ROADWAY PAVEMENT CEMENT CONCRETE SIDEWALK PAVEMENT LEGEND: HMA FULL-DEPTH PAVEMENT CEMENT CONCRETE ROADWAY PAVEMENT CEMENT CONCRETE SIDEWALK PAVEMENT CEMENT CONCRETE N SCALE IN FEET 0 4020 8040 (1" = 40') CONTRACT UNIT DESCRIPTION 5 CIVIL PAVING PLAN SOUTH RENTON TC 405-CPP501 17 0 1" = 40' HARDIE AVE SWNo.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/04/22 | 4:26 PM | USRS670585C:\BMS\WSP-PB-US-PW-02\WSP__RONALD.SMITH2\D0342984\BRT-405-CPP500.DWGBRT-405-CPP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022RAINIER AVE S UT H HHH / / ///////// T T E F O FO F OICVICV ICVICVICVICVICVICVICV ICV E CO EE E EE E E WE ////////// //SSCCB P-1E L = 2 BOR E HO LE P - 1 2 E L = 2 5 . 1 4 BORE HO L ERW1 0EL = 2 5 . 3 0BOR E H OL P - 1 5 E L = 2 5 . 6 6 RAINIER A V E S SW 7TH ST HARDI E A V E S W 4 0 5 -C -R a i n i e r S 405-C- H a r di e S W 4 0 5 - C -G r a d yW 405-C -SW7THST STA 15+53.63, 38.88' LT STA 19+90.57, 2.03' LT 405-C-RainierS STA 20+88.27, 13.25' LT STA 17+52.04, 44.57' LT STA 16+50.78, 41.33' LT STA 17+88.05, 12.98' RT STA 17+88.02, 12.22' RT STA 17+87.17, 2.36' RT STA 12+76.23, 49.50' RT STA 12+32.69, 49.49' RT STA 14+07.84, 49.45' RT STA 15+20.60, 49.52' RT R2 5 . 0 ' STA 14+35.70, 49.32' RT STA 17+85.11, 49.66' RT STA 16+30.79, 49.42' RT STA 16+62.86, 49.55' RT STA 16+68.25, 54.44' RT STA 17+00.61, 57.48' RT STA 17+24.21, 56.79' RT STA 17+58.36, 56.12' RT STA 17+63.48, 49.63' RTR12.5 'R13.5'R60 . 0 ' R3 0 . 0 ' STA 748+79.37, 23.16' RT STA 748+79.56, 24.67' LT STA 749+20.46, 25.00' RT R5.0' STA 10+43.92, 13.00' LT STA 10+43.92, 13.00' RT STA 10+32.42, 13.00' RT STA 10+18.35, 13.00' LT STA 15+74.85, 44.72' LT STA 15+85.51, 66.27' LT STA 15+92.60, 53.45' LT STA 16+24.05, 46.56' LT R5 . 0 ' 10+09 12+0 0 14+00 16+00 18+00 20+00 22+00 747+ 0 0 748+ 0 0 750+00750+00150+00 1 5 2 + 0 0 248+0010+00 12+0010+00 12+009+5110+0012+006.5'13.5 '6.0 '8.0'7.5' R25.0' 26.0' 50.0'13.0'13.0'12.0'23.5'19.5'17.5'PROPERTY LINE, TYP SEE SHEET 405-CPP501 FOR TRANSIT CENTER PAVING IMPROVEMENTS 45 9 38 2 38 9 1 45 9 6 45 R4.5' 6 38 6 10 10 38 1 1 38 38 38 11 38 38 38 1 PROPERTY LINE, TYP 1 1 2 1 29 2 2 R4.0' R 4 . 0 ' STA 16+28.98, 3.63' LT STA 16+38.93, 3.98' LT STA 16+52.74, 4.85' LT STA 16+57.86, 5.06' LT STA 16+29.22, 13.58' RT STA 16+39.37, 13.42' RT STA 16+53.70, 13.52' RT STA 16+62.04, 13.56' RT R4' STA 17+67.37, 6.54' RT STA 17+59.81, 6.70' RT STA 12+64.94, 16.13' LT STA 13+28.21, 18.03' LT STA 13+59.24, 15.71' LT 9 STA 15+75.61, 62.19' LT STA 15+95.31, 58.10' LT 1 GENERAL NOTES: 1.SEE SHEETS 405-CRY501 - 505 FOR TYPICAL ROADWAY SECTIONS. 2.SEE SHEETS 405-CAV501 - 504 FOR ROADWAY AND DRIVEWAY PLAN AND PROFILES. 3.SEE SHEETS 405-CXP501 - 502 FOR DEMOLITION AND REMOVAL PLANS. 4.SEE SHEETS 405-CDP501 - 502 FOR DRAINAGE PLANS. 5.SEE SHEETS 405-CMP501 - 502 AND 405-TNP501 - 502 FOR PAVEMENT MARKING AND SIGNAGE PLANS. 6.SEE SHEETS 405-UCP501 - 502 FOR UTILITY PLANS. 7.EXISTING FACILITIES TO BE PROTECTED-IN-PLACE UNLESS OTHERWISE NOTED. 8.FOR ITEMS NOT SHOWN, SEE DRAINAGE, TRAFFIC, AND UTILITY SHEETS. 9.SEE SHEET 405-LHP501 FOR HARDSCAPE PLANS. 10.SEE SHEETS 405-CAP501 - 502 FOR ALIGNMENT PLANS. 11.AT PROPOSED CURBS, STATION AND OFFSET CALLOUTS ARE PROVIDED FOR ALL GEOMETRY POINTS, INCLUDING BEGINNING AND END. RADIUS AND STATION AND OFFSET CALLOUTS ARE AT THE FACE OF CURB. 12.DESIGN ELEMENTS REFERENCE STANDARD PLANS IN ACCORDANCE WITH THE JURISDICTION IT FALLS WITHIN. FOR LINEAR ELEMENTS CROSSING PROPERTY LINES, SPLIT SHALL OCCUR AT GEOMETRY POINT CLOSEST TO THE PROPERTY LINE. CONSTRUCTION NOTES: 1 INSTALL CEMENT CONCRETE CURB AND GUTTER PER WSDOT STD PLAN F-10.12-04 2 INSTALL CEMENT CONCRETE SIDEWALK PER WSDOT STD PLAN F-30.10-04 3 INSTALL CEMENT CONCRETE ADA PERPENDICULAR CURB RAMP PER KCM STD PLAN D110. GRADING DETAIL TO BE PROVIDED AT 90%. 5 INSTALL CEMENT CONCRETE DRIVEWAY ENTRANCE TYPE 1 PER WSDOT STD PLAN F-80.10-04 6 INSTALL RAISED MEDIAN PER TYPICAL SECTIONS SHEETS. DETAIL TO BE PROVIDED AT 90%. 9 INSTALL HMA ROADWAY PAVEMENT PER TYPICAL SECTIONS SHEETS 12 INSTALL HMA DRIVEWAY PAVEMENT PER TYPICAL SECTIONS SHEETS 14 INSTALL CEMENT CONCRETE DRIVEWAY TYPE-1 10 INSTALL CEMENT CONCRETE PAVEMENT PER KCM STD PLAN D108A 11 INSTALL HMA OVERLAY PAVEMENT PER TYPICAL SECTIONS SHEETS 38 INSTALL CEMENT CONCRETE ADA PERPENDICULAR CURB RAMP PER WSDOT STD PLAN F-40.15-04. GRADING DETAIL TO BE PROVIDED AT 90%. 45 INSTALL MODIFIED CEMENT CONCRETE EXTRUDED CURB, TYPE 6. DETAIL TO BE PROVIDED AT 90%. 29 INSTALL INTEGRAL DOWELED CURB PER KCM STD PLAN D109 LEGEND: HMA OVERLAY PAVEMENT CEMENT CONCRETE ROADWAY PAVEMENT CEMENT CONCRETE SIDEWALK PAVEMENT LEGEND: HMA FULL-DEPTH PAVEMENT HMA OVERLAY PAVEMENT CEMENT CONCRETE ROADWAY PAVEMENT CEMENT CONCRETE SIDEWALK PAVEMENT CONTRACT UNIT DESCRIPTION 5 CIVIL PAVING PLAN RAINIER AVE S 405-CPP502 18 0 1" = 40' No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/04/22 | 4:30 PM | USRS670585C:\BMS\WSP-PB-US-PW-02\WSP__RONALD.SMITH2\D0342984\BRT-405-CPP500.DWGBRT-405-CPP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 N SCALE IN FEET 0 4020 8040 (1" = 40') S GR AD Y W A Y EG FG 20 40 25.79+49 25.49+60 24.29+80 23.610+00 24.0824.210+20 24.5324.510+40 24.9824.810+60 25.4325.110+80 25.8825.211+00 26.3325.711+20 26.7826.011+40 27.2326.311+60 27.4526.411+80 27.3326.412+00 27.2126.312+20 27.0926.112+40 26.9726.012+60 26.8526.012+80 26.7225.913+00 26.6025.913+20 26.6526.013+40 26.7526.513+60 26.8526.713+80 26.9526.814+00 27.0526.814+20 27.1527.014+40 27.2527.014+60 27.3526.014+80 27.4526.015+00 27.5526.215+20PVI 10+00.00EL= 23.63PVI 11+72.00EL= 27.50PVI 13+24.59EL= 26.58-0.60%0.50% 2.25% EG FG 20 40 27.6526.515+40 27.7526.815+60 27.8527.115+80 27.9527.316+00 28.0527.516+20 28.1527.716+40 28.2527.716+60 28.3527.816+80 28.4527.917+00 28.1027.917+20 27.3527.817+40 26.6027.417+6017+70PVI 17+09.22EL= 28.50PVI 17+64.99EL= 26.42-3.73% No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/03/22 | 4:24 PM | USRS670585C:\BMS\WSP-PB-US-PW-02\WSP__RONALD.SMITH2\D0342984\BRT-405-CAV500.DWGBRT-405-CAV500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELI MI N A RY 405 R. GORMAN 02/11/2022 MATCHLINE - SEE BELOWMATCHLINE - SEE ABOVECONTRACT UNIT DESCRIPTION 5 CIVIL VERTICAL ALIGNMENT AND SUPERELEVATION PLAN SOUTH RENTON TC 405-CAV501 19 0 H: 1"=20', V: 1"=5' 405-C-CENTERISLAND N LINE SCALE: H: 1"=20', V: 1"-5' 20 40 SCALE IN FEET 01020 (1" = 20') HORIZONTAL SCALE: SCALE IN FEET 02.5 55 10 (1" = 5') VERTICAL SCALE: EG FG 20 40 0.44%-0.75% 3.13% 2.50%PVI 10+00.00EL= 23.60PVI 10+50.00EL= 25.17PVI 11+57.65EL= 27.86PVI 13+33.01EL= 26.54- 3.03%25.69+51 25.39+60 24.29+80 23.6023.610+00 24.2324.210+20 24.8624.810+40 25.4225.410+60 25.9225.810+80 26.4226.311+00 26.9226.911+20 27.4227.311+40 27.8427.811+60 27.6928.011+80 27.5427.512+00 27.3927.512+20 27.2427.412+40 27.0927.412+60 26.9427.212+80 26.7926.813+00 26.6426.413+20 26.5826.213+40 26.6626.213+60 26.7526.413+80 26.8426.914+00 26.9326.914+20 27.0126.914+40 27.1026.914+60 27.1926.714+80 27.2826.515+00 27.3726.515+20 EG FG 20 40 0.30%-3.73%PVI 16+09.99EL= 27.76PVI 17+43.99EL= 28.16PVI 17+98.58EL= 26.1227.4526.615+40 27.5426.615+60 27.6326.715+80 27.7226.816+00 27.7927.016+20 27.8527.416+40 27.9127.816+60 27.9727.816+80 28.0327.717+00 28.0927.517+20 28.1427.317+40 27.5627.517+60 26.8127.917+80 25.718+00 25.918+20 25.718+30 FG 25.7325.7025.69No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/03/22 | 4:26 PM | USRS670585C:\BMS\WSP-PB-US-PW-02\WSP__RONALD.SMITH2\D0342984\BRT-405-CAV500.DWGBRT-405-CAV500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELI MI N A RY 405 R. GORMAN 02/11/2022 MATCHLINE - SEE BELOWMATCHLINE - SEE ABOVECONTRACT UNIT DESCRIPTION 5 CIVIL VERTICAL ALIGNMENT AND SUPERELEVATION PLAN SOUTH RENTON TC 405-CAV502 20 0 H: 1"=20', V: 1"=5' 405-C-CENTERISLAND S LINE SCALE: H: 1"=20', V: 1"-5' 20 40 SCALE IN FEET 01020 (1" = 20') HORIZONTAL SCALE: SCALE IN FEET 02.5 55 10 (1" = 5') VERTICAL SCALE: //////////////////////////EG FG 20 40 -0.50%0.50%-0.50% 5.01% SSD = 134.43 LVC 27.54' PVI 10+43.92EL 26.66 PVC 10+30.15EL 25.973 PVT 10+57.69EL 26.59PVI 9+99.14EL= 24.42PVI 11+79.67EL= 25.98PVI 13+15.42EL= 26.66PVI 14+90.00EL= 25.7925.99+49 26.29+60 24.99+80 24.4624.810+00 25.4625.910+20 26.3726.510+40 26.5827.010+60 26.4827.310+80 26.3827.411+00 26.2827.211+20 26.1827.011+40 26.0826.811+60 25.9926.811+80 26.0926.912+00 26.1927.312+20 26.2927.512+40 26.3927.612+60 26.4927.612+80 26.5927.513+00 26.6427.013+20 26.5426.613+40 26.4426.213+60 26.3426.313+80 26.2427.014+00 26.1427.614+20 26.0427.514+40 25.9427.414+60 25.8427.414+80 25.8327.915+00 25.9027.715+20 GARAGE FACE GARAGE FACE FG EG 20 40 -2.50% 1.50% 0.36%0.50%PVI 16+92.92EL= 26.52PVI 18+32.42EL= 27.21PVI 19+09.00EL= 25.30PVI 19+26.03EL= 25.5525.9727.415+40 26.0427.115+60 26.1126.815+80 26.1926.416+00 26.2626.616+20 26.3326.516+40 26.4026.316+60 26.4726.316+80 26.5626.417+00 26.6626.517+20 26.7526.617+40 26.8526.717+60 26.9526.917+80 27.0527.218+00 27.1527.518+20 27.0227.518+40 26.5227.418+60 26.0227.318+80 25.5226.319+00 25.4625.819+2019+30 No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/03/22 | 4:27 PM | USRS670585C:\BMS\WSP-PB-US-PW-02\WSP__RONALD.SMITH2\D0342984\BRT-405-CAV500.DWGBRT-405-CAV500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELI MI N A RY 405 R. GORMAN 02/11/2022 MATCHLINE - SEE BELOWMATCHLINE - SEE ABOVECONTRACT UNIT DESCRIPTION 5 CIVIL VERTICAL ALIGNMENT AND SUPERELEVATION PLAN SOUTH RENTON TC 405-CAV503 21 0 H: 1"=20', V: 1"=5' 405-C-RAINIER-LAKE-DRWY LINE SCALE: H: 1"=20', V: 1"-5' 20 40 SCALE IN FEET 01020 (1" = 20') HORIZONTAL SCALE: SCALE IN FEET 02.5 55 10 (1" = 5') VERTICAL SCALE: EG FG - 4.97% - 1.85% 20 40 20 40 PVI 10+03.74EL= 25.76PVI 10+38.16EL= 25.35PVI 11+87.92EL= 25.75PVI 12+33.65EL= 25.39PVI 14+70.00EL= 26.4126.89+7526.79+80 25.910+00 25.5725.410+20 25.3625.610+40 25.4125.610+60 25.4625.610+80 25.5225.711+00 25.5725.611+20 25.6325.511+40 25.6825.711+60 25.7325.711+80 25.6625.612+00 25.5025.412+20 25.4225.412+40 25.5025.512+60 25.5925.612+80 25.6825.713+00 25.7625.813+20 25.8525.813+40 25.9425.913+60 26.0225.913+80 26.1126.014+00 26.2026.014+20 26.2826.114+40 26.3726.314+60 26.4126.414+70 -1.19%0.27%-0.80%0.43% EG FG 20 40 20 40 -0.50%0.30%2.72%PVI 10+00.00EL= 26.93PVI 10+73.46EL= 26.56PVI 11+46.45EL= 26.78PVI 11+51.74 EL= 26.93 26.9327.710+00 26.8327.210+20 26.7327.110+40 26.6326.910+60 26.5826.610+80 26.6426.511+00 26.7026.411+20 26.7627.211+40 11+60 No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/03/22 | 4:29 PM | USRS670585C:\BMS\WSP-PB-US-PW-02\WSP__RONALD.SMITH2\D0342984\BRT-405-CAV500.DWGBRT-405-CAV500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELI MI N A RY 405 R. GORMAN 02/11/2022 CONTRACT UNIT DESCRIPTION 5 CIVIL VERTICAL ALIGNMENT AND SUPERELEVATION PLAN SOUTH RENTON TC AND LAKE AVE S 405-CAV504 22 0 H: 1"=20', V: 1"=5' 405-C-LAKEAVE S LINE SCALE: H: 1"=20', V: 1"-5' 405-C-GRADY-DRWY LINE SCALE: H: 1"=20', V: 1"-5' 20 40 SCALE IN FEET 01020 (1" = 20') HORIZONTAL SCALE: SCALE IN FEET 02.5 55 10 (1" = 5') VERTICAL SCALE: 16+ 0 0 18 + 0 0750+00750+00152+00154+0011+46 10+00 10+00 12+0014+0010+00 12+0014+009+5110+0012+0014+00XXXXXXXXXXXXXHHHHHCB2.2' X 1.9' CONCRIM=24.47IE 12" DI NW=21.4WAT=21.3 BOT=19.8INLETRIM=25.252.1' X 1.7' CONCIE 8" CONC N=23.2IE 4" CONC E=23.3IE 6" CONC E=23.3IE 6" X 6" SQUARE CONC W =23.1WAT=23.2 BOT=22.4CB2.2' X 1.9' CONCRIM=23.81IE 6" PVC NE=21.2IE 12" DI NW=20.8WAT=20.9 BOT=19.2CB2.2' X 1.9' CONCRIM=24.27IE 12" DI NW=21.1WAT=21.1 BOT=19.4INLETRIM=25.12INLETRIM=23.62CB2.2' X 1.9' CONCRIM=25.61IE 12" DI SW =22.7WAT=22.7 BOT=21.0INLETRIM=25.37CB2.1' X 1.9' CONCRIM=26.61IE 12" DI SE=22.7IE 12" DI W=22.7WAT=22.6 BOT=19.8INLETRIM=26.88CB2.1' X 1.8' CONCRIM=26.42IE 12" CPP NW=23.6WAT=23.2 BOT=21.8SDMH48"Ø BRICKRIM=28.89IE 30" CONC E=19.9IE 24" CONC W=19.8WAT=20.4 BOT=19.5CBRIM=26.78IE 8" DI S=25.5WAT=25.3 BOT=22.9CBRIM=25.90CB2.3' X 2.2' CONCRIM=25.65IE 6" DI S=24.5WAT=24.4 BOT=21.3CBRIM=27.64UNABLE TO ACCESSSDMH60"Ø CONCRIM=26.6212" CPP NE=UNABLE TO SEEIE 30" CONC NE=19.1IE 30" CONC W=19.4WAT=20.4 BOT=18.7CB1.7' X 2.2' CONCRIM=25.21IE 12" CPP SW=23.0WAT=23.0 BOT=22.6SDMH60"Ø CONCRIM=26.13IE 12" CPP NE=21.5IE 27" CONC E=19.7IE 30" CONC SW=19.2WAT=20.4 BOT=17.6SDSDSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSD SD SSE E EEEEEEEEEWWE E E W W W W W W W W W W W W W W W W W W W W W EE E E E E WG EGG EEEEEECOWWWW WW WWWWWW WWWE E WWTTEETT TTTT TEEEE E E E EEEEEE ETTTTTTT T T T T T EEEEEEEEEGEEEEEEE EEEEEEEEEEEEEEEEEEG G FO F O FOFOFOFOFO FO FOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOWWWWWWWWWWWW SDSDSDSDSDSDSDSD WWWFOF O F O F O FOFOFO FOFOFOFOFOFOFOFO FOFO FOSD S D S D SD SD SD SD SD SD SD SD SD SD SDSD SD SD SD SDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSSSSFOFOFO E E E E E E E E EEEEE E EE EEFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOCBRIM=25.71CBRIM=25.53INLETRIM EL=24.21NO PIPE, FULL OF PACKED DIRT/SILT/DEBRISCB36" CONCRIM EL=24.29IE 18" DI N=20.8IE 8" CPP NE=21.1IE 12" CPP E=21.2IE 18" DI SW=20.8WAT=20.9 BOT=17.8CB2.2' X 1.8' CONCRIM EL=24.04IE 18" DI NE=20.7IE 18" DI SW=20.7WAT=20.8 BOT=19.3CB2.2' X 1.8' CONCRIM EL=23.60IE 18" DI NE=20.5IE 12" CPP SE=20.8IE 18" DI SW=20.6WAT=20.5 BOT=19.4CB2.2' X 1.8' CONCRIM EL=23.39IE 18" DI NE=20.3IE 12" CPP E=20.7IE 18" DI SW=20.4WAT=20.4 BOT=19.3INLETRIM EL=25.09INLETRIM EL=25.04CB60" CONCRIM EL=24.37IE 24" CPP N=20.7IE 12" CPP NE=20.5IE 6" PVC S=21.2IE 24" CPP S=20.1WAT=20.4 BOT=18.2INLETRIM EL=24.37NEEDS TRAFFIC CONTROLINLET60" CONCRIM EL=25.34IE 24" CPP N=20.1IE 12" CPP E=20.7IE 6" PVC S=22.2IE 24" CPP S=23.0WAT=20.4 BOT=18.0INLETRIM EL=26.78UNABLE TO OPEN60" CONCRIM EL=28.35IE 24" CPP N=19.4IE 30" CPP NE=19.8IE 12" CPP S=21.7IE 36" CPP SW=19.6BOT=17.8SDMH48" CONCRIM EL=28.71IE 12" DI N=22.6IE 12" DI S=22.8WAT=22.6 BOT=20.6CB1.9' X 2.2' CONCRIM EL=28.02TOP OF 12" DI SE=24.3IE 12" DI N=23.2WAT=23.3 BOT=22.1CB1.9' x 2.2' CONCRIM EL=26.82IE 12" DI NE=23.7WAT=23.8 BOT=22.2INLETRIM EL=26.93NEEDS TRAFFIC CONTROLCB1.7' X 2.2' CONCRIM EL=26.55IE 4" CONC W=25.2WAT=25.2 BOT=24.9CB1.9' X 2.4 CONCRIM EL=26.10IE 8" CONC S=24.4WAT=24.7 BOT=21.8CB1.9' X 2.4' CONCRIM EL=25.63IE 6" DI W/ PLUG W=24.4WAT=23.9 BOT=20.9CB1.7' X 2.2' CONCRIM EL=25.70IE 6" DI SW/ PLUG W=25.0WAT=24.4 BOT=21.1CB1.7' X 2.2' CONCRIM EL=25.18IE 6" PVC S=23.4IE 6" PVC S=23.3TOP OF 6" DI W=23.2WAT=22.7 BOT=21.0SDSDSD SDCBRIM EL=26.778" CONC N=NANEEDS TRAFFIC CONTROLINLETRIM EL=26.88NEEDS TRAFFIC CONTROLGGGFOFOFOFOFOFOE E E E E E EEEEEEEEEEEEEEEEEEEEEFOFOEEFOFOFOFOSSSS SSFOSS SS SS SS SS SSEEEEE WWWTTTTTTTTTTTTTTTT GGGGGGGGGGGGGG G GGGGGGG EEE E E E E EEEEEEE EEEE WWWWWWGGGGE E WWEEEEEEEE E EEEEEE E E WWWWWEEEEEEEEE E EEEC C C C C C C T T T T T T T T E ETTT E EG G G C CE EGE E EEEEEEEEEEEECHARGERCHARGERCHARGERCHARGERCHARGERCHARGERCHARGERCHARGERSWITCHGEARCHARGERCHARGERCHARGERITCHARGERSDSDSD SDSDSDSDSDSDSD SD SD SDSDSDSDSD SDSDS GRADY WAYRA I N I E R A V E S HARDIE AVE SW 405-C-GradyW405-C-HardieSW405-C-Rainier-Lake-Drwy STA 14+89.91, 11.08' RT RIM=25.6' IE(N)(W)(E)=24.0' 6 405-C-Rainier-Lake-Drwy STA 14+09.57, 17.79' RT RIM=26.7' IE(S)(N)(E)=23.3' 6 405-C-GradyW STA 153+36.11, 76.62' LT END CABS IE(OUT)=20.9' 19 405-C-RainierS STA 12+16.94, 78.78' RT RIM=27.8' EX IE(W)=19.8' IE(SE)=19.8' 2 9 405-C-CenterIslandN STA 13+26.01, 16.63' RT RIM=26.3' IE(N)(S)=24.6' 6 405-C-CenterIslandN STA 13+28.34, 16.74' LT RIM=26.3' IE(S)=24.8' 6 405-C-CenterIslandN STA 10+22.35, 14.38' RT END TRENCH DRAIN RIM=23.7' IE(N)(S)=23.1' 4 405-C-CenterIslandN STA 10+22.23, 14.22' LT BEGIN TRENCH DRAIN RIM=23.8' IE(S)=23.3' 10 405-C-Grady-Drwy 405-C-RainierS STA 11+56.93, 113.85' RT RIM=28.3' IE(NW)(E)=19.8' 9 405-C-Rainier-Lake-Drwy STA 14+90.12, 11.04' LT RIM=25.6' IE(W)(E)=24.1' 6 405-C-CenterIslandS STA 13+39.99, 56.44' RT RIM=26.8' IE(W)=24.8' IE(N)(S)=24.1' 6 EXISTING ROW, TYP 23 5e 5c 21 20 5d 5c 20 5b 5b 5b 5b 20 5a 5b 405-C-GradyW STA 153+09.88, 116.28' LT RIM=27.4' IE(E)(W)=19.8' IE(S)=20.4' 9 405-C-GradyW STA 153+09.60, 76.78' LT RIM=25.1' IE(N)(E)=20.6' IE(S)=23.9' 6 405-C-GradyW STA 153+17.35, 66.60' LT END DITCH APPROX. IE=24' 19 405-C-GradyW STA 154+00.06, 115.68' LT RIM=27.1' IE(NE)(W)=19.8' 9 405-C-Grady-Drwy STA 10+49.77, 59.42' RT BEGIN CABS IE(IN)=22.8' 11 405-C-GradyW STA 155+24.26, 55.33' LT END CULVERT BEGIN DITCH 15 405-C-Rainier-Lake-Drwy405-C-CenterIslandS405-C-CenterIslandN405-C-CenterIslandS STA 13+32.95, 14.91' RT RIM=26.5' IE(N)(S)=24.3' 6 405-C-CenterIslandS STA 13+36.05, 16.75' LT RIM=26.4' IE(N)(S)=24.4' 6 405-C-CenterIslandS STA 10+23.04, 25.34' RT RIM=24.9' IE(N)=20.6' IE(W)=20.6' 6 405-C-CenterIslandS STA 10+25.15, 16.98' RT RIM=24.9' IE(N)=22.8' IE(S)=20.7' 12 405-C-CenterIslandS STA 10+23.09, 13.28' RT END TRENCH DRAIN RIM=24.4' IE(N)(S)=23.0' 4 405-C-CenterIslandS STA 10+22.92, 13.32' LT BEGIN TRENCH DRAIN RIM=24.4' IE(N)(S)=23.0' 4 5e 5c 405-C-GradyW STA 155+77.53, 54.78' LT END DITCH BEGIN CULVERT 17 405-C-Rainier-Lake-Drwy STA 13+63.89, 26.06' RT RIM=26.1' EX IE(NE)=19.4' IE(SW)=19.8' 2 9 405-C-CenterIslandS STA 13+49.21, 170.68' RT RIM=25.6' IE(S)=23.6' IE(N)=23.6' 6 22 22 24 26 CONSTRUCTION NOTES: 1 CONNECT TO EXISTING CATCH BASIN OR MANHOLE. 6 INSTALL CATCH BASIN TYPE 1 PER COR STD PLAN 200.00. 11 INSTALL CABS WITH 128.5 FT LENGTH AND 14 FT WIDTH AT 1.5% SLOPE. SEE DRAINAGE DETAIL SHEETS. 12 INSTALL 5' X 7' MODULAR WETLAND TREATMENT UNIT #1. SEE DRAINAGE DETAIL SHEETS. 9 INSTALL 54" MANHOLE PER COR STD PLAN 201.00. 10 INSTALL 8" WIDE TRENCH DRAIN. SEE DRAINAGE DETAIL SHEETS. 4 CONNECT TRENCH DRAIN TO 8" SD WITH TRENCH DRAIN END CAP AND PIPE CONNECTION FITTING. 5 INSTALL SD WITH PIPE ZONE BEDDING, COMPACTION, AND BACKFILL PER COR STD PLAN 220.00, 220.10, AND 220.20. 15 INSTALL DITCH. MINIMUM SLOPE OF 0.5%. 2 CONNECT TO EXISTING SD. 17 INSTALL 12" CULVERT WITH APPROX. LENGTH OF 53 LF. 19 GRADE DITCH TO MATCH INVERT OF PIPE INLET. 20 CONNECT GARAGE ROOF DRAINAGE SYSTEM TO MH/CB. SIZE AND LOCATION TO BE DETERMINED IN NEXT PHASE. THIS INCLUDES SEPARATE ROOF DRAIN DOWNSPOUTS FROM ELEVATOR AND STAIRWELL ROOFS. 21 POTHOLE FOR POTENTIAL CONFLICT PRIOR TO NEXT DESIGN PHASE. 22 PLUG AND ABANDON EXISTING 30" OUTLET/INLET. 23 THE CITY OF RENTON ON-SITE STORMWATER MANAGEMENT BMP REQUIREMENT APPLIES UNLESS THE PROJECT IS EXEMPT DUE TO SOIL SUITABILITY. ADDITIONAL SOILS INVESTIGATIONS ARE NEEDED TO CONFIRM SOIL SUITABILITY. THIS WILL BE CONFIRMED DURING INFILTRATION TESTS AS PART OF FUTURE DESIGN. 5b 8" DUCTILE IRON PIPE 5d 12" DUCTILE IRON PIPE 5e 30" PIPE 5a 8" PIPE 5c 12" PIPE 26 DEPTH OF EXISTING COMM AND POWER TO BE ADJUSTED TO AVOID CONFLICT WITH NEW SD. GENERAL NOTES: 1.SEE CDD SHEETS FOR DRAINAGE DETAILS. 2.SEE CRY SHEETS FOR TYPICAL ROADWAY SECTIONS. 3.SEE CXP SHEETS FOR DEMOLITION AND REMOVAL PLANS. 4.SEE CPP SHEETS FOR PAVING PLANS. 5.SEE UCP SHEETS FOR UTILITY PLANS. 6.EXISTING FACILITIES TO BE PROTECTED-IN-PLACE UNLESS OTHERWISE NOTED. 7.FOR PROPOSED IMPROVEMENTS NOT SHOWN, SEE PAVING, TRAFFIC, AND UTILITY SHEETS. No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:01/31/22 | 5:28 PM | USMB682252C:\BMS\D0342984\BRT-405-CDP500.DWGBRT-405-CDP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 NSCALE IN FEET 0 30 601530 (1" = 30') CONTRACT UNIT DESCRIPTION 5 CIVIL DRAINAGE PLANS SOUTH RENTON TC 405-CDP501 23 0 1" = 30' MATCHLINE - SEE SHEET 405-CDP502 13 INSTALL 5' X 7' MODULAR WETLAND TREATMENT UNIT #2. SEE DRAINAGE DETAIL SHEETS. 5a 8" PIPE 16 CONFIRM THIS SD IS ABANDONED AND CAN BE REMOVED/ABANDONED. 5c 12" PIPE CONSTRUCTION NOTES: 1 CONNECT TO EXISTING CATCH BASIN OR MANHOLE. 6 INSTALL CATCH BASIN TYPE 1 PER COR STD PLAN 200.00. 5 INSTALL SD WITH PIPE ZONE BEDDING, COMPACTION, AND BACKFILL PER COR STD PLAN 220.00, 220.10, AND 220.20. 15 INSTALL DITCH. MINIMUM SLOPE OF 0.5%. 21 POTHOLE FOR POTENTIAL CONFLICT PRIOR TO NEXT DESIGN PHASE. 23 THE CITY OF RENTON ON-SITE STORMWATER MANAGEMENT BMP REQUIREMENT APPLIES UNLESS THE PROJECT IS EXEMPT DUE TO SOIL SUITABILITY. ADDITIONAL SOILS INVESTIGATIONS ARE NEEDED TO CONFIRM SOIL SUITABILITY. THIS WILL BE CONFIRMED DURING INFILTRATION TESTS AS PART OF FUTURE DESIGN. 5b 8" DUCTILE IRON PIPE 5d 12" DUCTILE IRON PIPE GENERAL NOTES: 1.SEE CDD SHEETS FOR DRAINAGE DETAILS. 2.SEE CRY SHEETS FOR TYPICAL ROADWAY SECTIONS. 3.SEE CXP SHEETS FOR DEMOLITION AND REMOVAL PLANS. 4.SEE CPP SHEETS FOR PAVING PLANS. 5.SEE UCP SHEETS FOR UTILITY PLANS. 6.EXISTING FACILITIES TO BE PROTECTED-IN-PLACE UNLESS OTHERWISE NOTED. 7.FOR PROPOSED IMPROVEMENTS NOT SHOWN, SEE PAVING, TRAFFIC, AND UTILITY SHEETS.156+00158+00160+00161+00 19+2616+001 8 + 0 0 17+6516+0016+0018+0018+3014+70 9+75 10+00 12+00 14+00XXIE 12" CPP NE=21.5IE 27" CONC E=19.7IE 30" CONC SW=19.2WAT=20.4 BOT=17.6CB2.1' X 1.6' CONCRIM=25.47IE 8" CONC N=24.1IE 12" CPP SW=24.0WAT=24.0 BOT=23.6CB2.1' X 1.8' CONCRIM=26.15IE 12" CONC N=20.3IE 12" UNK S=19.9WAT=20.6 BOT=18.8SDMHRIM=26.16UNABLE TO OPENCB1.6' X 2.1' CONCRIM=25.82IE 4" CONC S=24.1IE 12" CPP NW=24.1WAT=23.9 BOT=23.2CB1.4' X 1.4' CONCRIM=26.93N PIPE NOT VISIBLEIE 6" DI W=26.0WAT=26.4 BOT=24.5SDMH60"Ø CONCRIM=27.40IE 27" CONC W=19.8IE 27" CONC NE=19.4WAT=19.6 BOT=18.9SDMH36"Ø CONCRIM=25.24N PIPE NOT VISIBLEIE 24" CMP E=19.3IE 27" CONC SW=19.2WAT=20.6 BOT=19.1CB2.2' X 1.9' CONCRIM=24.95IE 16" CONC SE=20.9WAT=21.5 BOT=19.3CB2.3' X 1.9' CONCRIM=25.94IE 12" CONC S=20.5IE 12" CONC NW=20.3WAT=20.7 BOT=19.2SD SD SD ETTTTTTTEEEEEEEEEEEEEEEEEEEEEE E EEEEEEEEEE EEEE WWTEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEFOFOFOFOFOFOFO FO FOFOFOFOFOFOFOFOF O FOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOF O F O F O F O FOF O F O F O FOWWWWWWWWWWWWWFOFOFOFOFOFO SDSDSDSDSDS D SD SD SDSDSDSDSDSDSDSDSDSDSDSD SD SD FOFOFOFOFOCB2.2' X 1.9' CONCRIM EL=25.02IE 12" RCP E=21.8WAT=21.9 BOT=20.4CB1.7' X 2.2' CONCRIM EL=25.80IE 8" CPP N=22.6IE 8" CPP SE=22.6IE 8" CPP SW=22.6WAT=22.6 BOT=21.1CB1.9' X 2.2' CONCRIM EL=24.23IE 8" CONC E=22.5IE 8" CPP S=22.6IE 8" CONC W=22.6WAT=22.6 BOT=22.6CB2.2' X 1.9' CONCRIM EL=24.72IE 12" RCP N=22.3IE 12" RCP S=22.2WAT=22.2 BOT=20.4CB1.9' X 2.2' CONCRIM EL=24.68IE 12" RCP NE=21.1IE 12" RCP W=21.0WAT=21.7 BOT=19.8CB1.7' X 2.2' CONCRIM EL=25.92IE 12" RCP N=21.8IE 8" CONC E=21.2IE 12" RCP S=21.6IE 8" CONC W=22.7WAT=21.7 BOT=20.8CB1.9' X 2.2' CONCRIM EL=25.33IE 8" CONC E=23.8WAT=23.4 BOT=22.8CBRIM=27.30UNABLE TO ACCESSSDSDSDSDMHRIM=24.94NEEDS TRAFFIC CONTROLSDMHRIM=15.02NEEDS TRAFFIC CONTROLCBRIM=25.13NEEDS TRAFFIC CONTROLFOFOFOFOFOFOFOFOFOFOFOFOFOFO FO FO FOFOFOFO FOFO FO FOFOFOFOFOFOFO FO FO FO FO FO SSSSSSSSSSSSWWWWWWWWWWSSSSSSFOSDSDSDSDSDSDSSSS SS SS SSSSSSSSSSSSSSSSSS SSSSSS SS SSSSSSSS SS WWEEEEEETRANSFORMERCHARGERITSDSDSD SDSDSDSDSDSDSD SDSDSDSDLAKE AVE S 4 0 5 -C -R a i n i e r - L a k e -D rw y PROPERTY LINE, TYP 16 5b 16 21 5b 5d 5d 5a 5b 5d 5d 5c 405-C-Rainier-Lake-Drwy STA 18+63.65, 11.43' RT RIM=26.2' IE(N)(SW)=23.6' 6 405-C-Rainier-Lake-Drwy STA 18+84.19, 10.63' LT RIM=25.7' IE(N)(SW)=23.7' 6 405-C-CenterIslandN STA 17+56.70, 14.89' LT RIM=26.7' IE(S)=24.6' 6405-C-CenterIslandN405-C-CenterIslandS405-C-CenterIslandS STA 17+93.54, 34.06' LT RIM=25.9' IE(N)(S)=24.4' 6 405-C-CenterIslandS STA 17+91.42, 14.11' RT RIM=26.2' IE(N)(S)=24.2' 6 405-C-GradyW405-C-Lake A ve-S 405-C-GradyW STA 158+17.12, 55.61' LT BEGIN DITCH15 405-C-Rainier-Lake-Drwy STA 16+93.88, 11.26' LT RIM=26.3' IE(W)=23.2' IE(N)=23.2' 6 405-C-Rainier-Lake-Drwy STA 16+02.71, 12.07' RT RIM=25.3' IE(NE)=23.7' 6 405-C-Rainier-Lake-Drwy STA 16+95.08, 23.01' LT RIM=26.8' IE(N)(S)=23.1' 6 405-C-Rainier-Lake-Drwy STA 17+64.78, 56.19' LT EX RIM=27.4' EX IE(W)=19.8' EX IE(E)=19.4' IE(NW)=24.7' IE(SW)=20.6' 1 405-C-Rainier-Lake-Drwy STA 17+39.96, 112.84' LT RIM=27.4' IE(SE)=25.4' 6 405-C-Rainier-Lake-Drwy STA 17+32.69, 66.21' LT RIM=27.8' IE(S)(E)=20.7' 6 405-C-Rainier-Lake-Drwy STA 17+29.56, 58.53' LT RIM=27.2' IE(N)=20.8' IE(S)=22.9' 13 405-C-Rainier-Lake-Drwy STA 17+23.61, 54.95' LT RIM=27.8' IE(N)(S)(E)=22.9' 6 405-C-LakeAve-S STA 11+85.33, 26.28' RT RIM=25.4' IE(N)=21.9' 6 405-C-LakeAve-S STA 12+33.83, 14.01' RT RIM=25.2' IE(W)=21.4' IE(S)=21.4' 6 405-C-LakeAve-S STA 12+33.43, 14.23' LT RIM=25.2' IE(N)=21.7' IE(E)=21.7' 6 405-C-LakeAve-S STA 14+16.06, 21.95' LT RIM=25.9' IE(S)=23.6' 6S GRADY WAY23 405-C-LakeAve-S STA 12+12.58, 16.27' RT EX RIM=25.3' IE(N)=21.2' IE(S)=21.2' EX IE (SE)=20.9' 6 CONTRACT UNIT DESCRIPTION 5 CIVIL DRAINAGE PLANS SOUTH RENTON TC 405-CDP502 24 0 1" = 30' No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:01/31/22 | 5:31 PM | USMB682252C:\BMS\D0342984\BRT-405-CDP500.DWGBRT-405-CDP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 NSCALE IN FEET 0 30 601530 (1" = 30') MATCHLINE - SEE SHEET 405-CDP501 10+09 12+0 0 14+00 16+00 18+00 20+00 22+00 747+ 0 0 748+ 0 0 750+00750+00150+00 1 5 2 + 0 0 248+001011+47 10+00 12+0010+00 12+009+5110+0012+00X X UT H HHH H CB 1 . 7 ' X 2 . 1 ' CON CRIM = 2 4 . 6 8 IE 6 " CO NC N = 2 3 . 4 IE 6 " C P P E = 2 3 . 5 I E 6 " CO NC S = 2 3 . 3WAT = 2 3 . 4 BO T = 2 2 . 0YARD D R A IN 0 . 9 ' X 0 . 9 ' CONCRIM = 2 4 . 9 6 IE 6 " P VC SW = 2 4 . 0BOT = 2 3 . 6 Y AR D D R A IN 0 . 9 ' X 0 . 9 ' C O NCRIM = 2 5 . 1 7 IE 6 " P V C N E = 2 4 . 0 IE 6 " PV C SW = 2 4 . 0 BO T = 2 3 . 7 I N L E TRIM = 2 4 . 2 0 CB 2 . 2 ' X 1 . 9 ' CO NC R IM = 2 4 . 0 7 IE 1 2 " D I S E = 2 1 . 5WA T = 2 1 . 5 BO T = 1 9 . 6 C B 2 . 3 ' X 2 . 1 ' CON CRIM = 2 4 . 5 8 I E 6 " C O NC N E = 2 3 . 4WAT = 2 3 . 4 BO T = 2 0 . 7 IN L E TRIM = 2 3 . 9 7 CBRIM = 2 3 . 7 9 CBRIM = 2 4 . 5 1 CB 2 . 2 ' X 1 . 9 ' CO NC R IM = 2 4 . 2 5 I E 6 " D I N = 2 2 . 3 IE 1 2 " D I S E = 2 1 . 7 IE 1 2 " D I NW = 2 1 . 6WA T = 2 1 . 7 B O T = 2 0 . 1CB2 . 2 ' X 1 . 9 ' CONCRIM = 2 4 . 4 7 I E 1 2 " D I NW = 2 1 . 4WAT = 2 1 . 3 BO T = 1 9 . 8 I N L E TRIM = 2 5 . 2 5 CB 1 . 7 ' X 2 . 2 ' CO NC R IM = 2 4 . 7 4 I E 6 " C ON C W = 2 3 . 9WA T = 2 3 . 8 BO T = 2 2 . 0CB 2 . 1 ' X 1 . 7 ' CONC R IM = 2 4 . 6 4 I E 8 " CON C N = 2 3 . 2 I E 4 " CON C E = 2 3 . 3 I E 6 " CON C E = 2 3 . 3 IE 6 " X 6 " SQ U AR E CON C W = 2 3 . 1WA T = 2 3 . 2 B O T = 2 2 . 4 S DM H 3 6 "Ø B R IC KRIM = 2 4 . 9 3 I E 1 2 " CONC N = 1 9 . 1 I E 6 " CO NC E = 2 0 . 2 I E 1 2 " CO NC S = 1 9 . 3 I E 8 " D I NW = 2 2 . 0WA T = 1 9 . 2 BO T = 1 7 . 6 C B 2 . 2 ' X 1 . 9 ' C ON CRIM = 2 3 . 8 1 I E 6 " PV C N E = 2 1 . 2 I E 1 2 " D I NW = 2 0 . 8WAT = 2 0 . 9 BO T = 1 9 . 2CB 2 . 2 ' X 1 . 9 ' CON CRIM = 2 4 . 2 7 I E 1 2 " D I NW = 2 1 . 1WA T = 2 1 . 1 BO T = 1 9 . 4 I N LE T R IM = 2 5 . 1 2 IN L E TRIM = 2 3 . 6 2SDMH3 6 "Ø CO NC R IM = 2 5 . 7 8 I E 1 2 " C O NC N = 2 0 . 5WA T = 2 0 . 6 BO T = 1 9 . 3 CB 2 . 2 ' X 1 . 9 ' CO NC R IM = 2 5 . 6 1 I E 1 2 " D I SW = 2 2 . 7WA T = 2 2 . 7 BO T = 2 1 . 0CB 2 . 3 ' X 2 . 0 ' CO NC R IM = 2 5 . 6 6 I E 1 2 " D I W = 2 2 . 2WA T = 2 2 . 2 BO T = 2 0 . 8 I N L E TRIM = 2 5 . 3 7 CB 2 . 1 ' X 1 . 9 ' CONCRIM = 2 6 . 6 1 I E 1 2 " D I S E = 2 2 . 7 I E 1 2 " D I W = 2 2 . 7WA T = 2 2 . 6 BO T = 1 9 . 8 I N LE T R IM = 2 6 . 8 8 CB 2 . 1 ' X 1 . 8 ' CO NC R IM = 2 6 . 4 2 I E 1 2 " CPP NW = 2 3 . 6WA T = 2 3 . 2 BO T = 2 1 . 8 S DMH 4 8 "Ø CON CRIM = 2 9 . 4 3 I E 1 2 " D I N = 2 0 . 6 I E 3 6 " D I E = 2 0 . 0 I E 3 6 " CM P S = 2 0 . 2 I E 1 2 " C ON C W = 2 0 . 0WA T = 2 0 . 4 BO T = 1 9 . 7 IN L E TRIM = 2 8 . 7 5 SDMH 4 8 " Ø B R IC KRIM = 2 8 . 8 9 I E 3 0 " CO NC E = 1 9 . 9 I E 2 4 " C O NC W = 1 9 . 8WA T = 2 0 . 4 BO T = 1 9 . 5 IN L E TRIM = 2 8 . 6 4 I N L E TRIM = 2 8 . 7 2 IN L E TRIM = 2 8 . 3 8 IN L E TRIM = 2 8 . 2 2 I N LE T R IM = 2 8 . 2 2 IN L E T R IM = 2 7 . 7 0 S DM H R IM = 2 8 . 7 4UNAB L E T O S E E P I P E SWA T = 2 0 . 3 BO T = 1 8 . 8 IN L E TRIM = 2 5 . 9 3 IN L E T R IM = 2 5 . 8 5 C BRIM = 2 6 . 7 8 I E 8 " D I S = 2 5 . 5WAT = 2 5 . 3 BO T = 2 2 . 9 C B 2 . 3 ' X 2 . 2 ' CON CRIM = 2 5 . 6 5 I E 6 " D I S = 2 4 . 5WAT = 2 4 . 4 BO T = 2 1 . 3 CBRIM = 2 7 . 6 4UNA B L E TO A C C ES S I E 1 2 " CO NC SW = 2 2 . 9WA T = 2 2 . 9 BO T = 2 1 . 7 SD SD C B R IM = 2 5 . 8 5 U N A B LE TO OP EN D U E TO B ROK EN H AND L ECB 2 . 2 ' X 1 . 9 ' CONC R IM = 2 5 . 4 4 IE 6 " PV C N E = 2 2 . 9 IE 1 2 " D I NW = 2 2 . 3WA T = 2 2 . 3 B O T = 2 0 . 7 C B 2 . 3 ' X 1 . 9 ' CO N C R IM = 2 4 . 8 1 I E 6 " D I SW = 2 2 . 7WA T = 2 1 . 0 BO T = 2 0 . 7 CB 2 . 2 ' X 1 . 9 ' CO NC R IM = 2 4 . 9 4 IE 1 2 " D I S E = 2 3 . 1 IE 6 " CO NC W = 2 3 . 2WA T = 2 3 . 0 B O T = 2 1 . 2 CB 2 . 2 ' X 1 . 9 ' CO NC R IM = 2 4 . 7 7 I E 6 " P VC S = 2 1 . 4 I E 6 " CON C SW = 2 1 . 7WA T = 2 1 . 4 BO T = 2 0 . 1CB 1 . 6 ' X 2 . 1 ' C O NC R IM = 2 4 . 4 9 I E 6 " CON C E = 2 3 . 5WA T = 2 3 . 7 BO T = 2 1 . 8 SD SD SD SDS S S S S S S S S S S S S SSSSSSSSSSSSS I N L E TRIM = 2 4 . 4 6 CBRIM = 2 4 . 4 6 T T E F O FO F OICVICV ICVICVICVICVICVICVICV ICV E CO EE E EE E E E WE E EE EE IN L E TRIM = 2 8 . 6 6 EEWE W W W W W W W W W W W W W W W EE E E E W WGGE EGEE EGG G G G G G G E E E E E E E E E E T T T E E E E E E E E E E E E E W E E E E EWTEEEW W W W W W WGGG G GGGG C O WWWW W WWE E WWTTE EEE EE EEEE E T TTTT T T T T EEEEGGEEE E E E E E E E E E E E E E E E E E E E E EE E E E E E EEEE EEEEE EEEE E E E E E E E EE EEEEE G G G G G G G GG GGG FO FO FO F O F O F O FO FO FO FO FOFOFOFOFOFO FO FOFOFO FO FO FO FO FOFOFOFO FO FO FO FOFO FO FO FOFOFOFO FOFOFOFO FOFO FO FOFOFO FO FO F O F O FO FO FO F O FO FO FO FOWWWW W W WW W W W W WWWSDSDSDSDSDSDSDSD SD SDFO FO FO FO FO FO FO FO FOFO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FOFOFO FO FO FOFO FO FO FO FO FO SD SDSD SD SD SD SD SD SD SD SD SD SD SDSD SD SD SD SD SD SD SD SD SDSDSD SDSDSD SDSSSSSS SSSSSSSSSSSSSSSSSSS S S S FO FO E EE E E E E E E E E E E E E E E EEEE E EEE E EEE EE E E E F O FO FOFOFOFOFOFOE E E FO FOFOFOFOFOFOFOFOFOFOFOFO FO FOFOCBRIM = 2 5 . 7 1CBRIM = 2 5 . 5 3 SDM HRIM = 2 5 . 4 7 S DMHRIM = 2 4 . 7 8 SDMH R IM = 2 4 . 7 7 N EE D S T R A F F I C CON TRO L C B 2 . 2 ' X 1 . 8 ' C O N C R IM E L = 2 5 . 3 6 I E 1 2 " C P P N E = 2 1 . 5 I E 1 2 " C P P S E = 2 1 . 5 IE 1 2 " C P P SW = 2 1 . 6WA T = 2 1 . 7 B O T = 1 9 . 9 SDMH R IM = 2 4 . 9 9 1 2 " C PP NW = N A N E E D S TRA F F IC C ON TRO L C B 2 . 2 ' X 1 . 8 ' CO N C R IM E L = 2 4 . 6 0 I E 1 2 " C P P S E = 2 0 . 8WA T = 2 0 . 8 B O T = 1 9 . 1 SDMH R IM = 2 5 . 5 9 N EE D S T R A F F I C CON TRO L S DMH R IM = 2 4 . 8 7NE ED S T R A F F I C CON TRO L IN LE T R IM E L = 2 4 . 5 7 N EE D S T R A F F I C CON TRO L RIG H T O F EN TRY N E ED E D FROM BU S I N ES S S DMHRIM = 2 5 . 1 3NEED S T R A F F I C CON TRO LSDM HRIM = 2 4 . 9 9NEEDS TR A F F IC CO N T RO L C B 2 . 2 ' X 1 . 8 ' C O N C R IM E L = 2 4 . 7 1 I E 1 2 " C P P N E = 2 1 . 4 I E 1 2 " C P P S E = 2 1 . 5 I E 1 8 " D I SW = 2 1 . 5WA T = 2 1 . 5 B O T = 2 0 . 3 IN L E TRIM E L = 2 4 . 2 1NO P I PE , F U L L O F PA C KE D D IR T / S I L T /DE BR I S C B 3 6 " C O N C R IM E L = 2 4 . 2 9 I E 1 8 " D I N = 2 0 . 8 I E 8 " C P P N E = 2 1 . 1 IE 1 2 " C P P E = 2 1 . 2 IE 1 8 " D I SW = 2 0 . 8WA T = 2 0 . 9 B O T = 1 7 . 8 C B 2 . 2 ' X 1 . 8 ' C O N C R IM E L = 2 4 . 0 4 I E 1 8 " D I N E = 2 0 . 7 I E 1 8 " D I SW = 2 0 . 7WA T = 2 0 . 8 B O T = 1 9 . 3 C B 2 . 2 ' X 1 . 8 ' C ON C R IM E L = 2 3 . 6 0 IE 1 8 " D I N E = 2 0 . 5 IE 1 2 " C P P S E = 2 0 . 8 IE 1 8 " D I SW = 2 0 . 6WA T = 2 0 . 5 BO T = 1 9 . 4 C B 2 . 2 ' X 1 . 8 ' C O N C R IM E L = 2 3 . 3 9 I E 1 8 " D I N E = 2 0 . 3 I E 1 2 " C P P E = 2 0 . 7 I E 1 8 " D I SW = 2 0 . 4WA T = 2 0 . 4 B O T = 1 9 . 3 IN L E T R IM E L = 2 5 . 0 9 IN L E TRIM E L = 2 5 . 0 4 C B 6 0 " C O N C R IM E L = 2 4 . 3 7 I E 2 4 " C P P N = 2 0 . 7 IE 1 2 " C P P N E = 2 0 . 5 IE 6 " P V C S = 2 1 . 2 IE 2 4 " C P P S = 2 0 . 1WA T = 2 0 . 4 BO T = 1 8 . 2 I N LE T R IM E L = 2 4 . 3 7 IN L E TRIM E L = 2 5 . 7 0NEEDS TR A F F IC CO N T RO L IN L E T R IM E L = 2 7 . 0 1NEED S T R A F F I C CON TRO L I N L E T 6 0 " C O N C R IM E L = 2 5 . 3 4 IE 2 4 " C P P N = 2 0 . 1 IE 1 2 " C P P E = 2 0 . 7 I E 6 " P V C S = 2 2 . 2 I E 2 4 " C P P S = 2 3 . 0WA T = 2 0 . 4 B O T = 1 8 . 0 IN L E TRIM E L = 2 6 . 7 8UNA B L E T O O P E N C B 6 0 " C O N C R IM E L = 2 8 . 3 5 I E 2 4 " C P P N = 1 9 . 4 I E 3 0 " C P P N E = 1 9 . 8 I E 1 2 " C P P S = 2 1 . 7 IE 3 6 " C P P SW = 1 9 . 6 B O T = 1 7 . 8 S DM H 4 8 " C O N C R IM E L = 2 8 . 7 1 IE 1 2 " D I N = 2 2 . 6 IE 1 2 " D I S = 2 2 . 8WA T = 2 2 . 6 BO T = 2 0 . 6 C B 1 . 9 ' X 2 . 2 ' C O N C R IM E L = 2 8 . 0 2 TO P O F 1 2 " D I S E = 2 4 . 3 I E 1 2 " D I N = 2 3 . 2WA T = 2 3 . 3 B O T = 2 2 . 1 C B 1 . 9 ' x 2 . 2 ' C ON C R IM E L = 2 6 . 8 2 IE 1 2 " D I N E = 2 3 . 7WA T = 2 3 . 8 B O T = 2 2 . 2 C B 1 . 9 ' X 2 . 4 ' C O N C R IM E L = 2 5 . 6 3 C B 1 . 7 ' X 2 . 2 ' C O N C R IM E L = 2 5 . 1 8 IE 6 " P V C S = 2 3 . 4 I E 6 " P V C S = 2 3 . 3 T O P O F 6 " D I W = 2 3 . 2WA T = 2 2 . 7 B O T = 2 1 . 0 SDI N L E T R IM E L = 2 6 . 8 8 N E E D S T R A F F I C C ON T R O L E E ESSSSSSSSSSSSSS SSSSSSSSSSSSSSFOFOFOFOE E E E EEEEEEEEEE E E ///////////// / / /// / //FOFOFOFOFOFOFOFOFO FOFOFO FOFOFOFO FOFOGG GG GGEEE GFO FOFOFOFOFOFO FO FO FO FOFOFOFOFOFOFOSS SS SS SS W W WWWWWWSD SD FO FO FO FO FO F O FOFOFOFOFOFOSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SS SS SS WWSD SD SD SD SD SDSSSSSSFOFOFO ESS SS SS EEEET TTT GGGGGGGG GG EEE E E E EEEEWWWWWGGGE E EE E E E EEEEW WWWEEE EE E E C C C C C T T T T T TEETT TEEG G CCEGE SDSD SD S D PROPERTY LINE, TYP 4 0 5 -C -R a in ie rS 405-C- H ar di e S W 4 0 5 - C -G r a d yW 405-C -SW7THST EXISTING ROW, TYP 405-C-RainierS 405-C-RainierS STA 17+97.76, 49.95' RT62 405-C-RainierS STA 18+02.60, 52.62' RT FILTERRA #314 405-C-RainierS STA 15+42.88, 47.70' RT62 405-C-RainierS STA 16+21.73, 52.06' RT FILTERRA #214 405-C-RainierS STA 16+17.49, 1.30' LT FILTERRA #114 405-C-RainierS STA 16+25.57, 6.65' LT1 405-C-RainierS STA 18+00.10, 10.60' LT118 405-C-RainierS STA 17+89.77, 0.40' RT6 405-C-RainierS STA 18+07.75, 48.95' RT18 405-C-RainierS STA 16+54.86, 48.64' RT RIM=23.4' IE(E)=20.5' EX IE(NE)=20.3' EX IE(SW)=20.4' 1 405-C-RainierS STA 15+34.72, 53.45' RT FILTERRA #414 405-C-RainierS STA 15+97.46, 4.24' LT18 405-C-RainierS STA 16+29.49, 49.77' RT62 24 24 2425 2 CONNECT TO EXISTING SD. CONSTRUCTION NOTES: 6 INSTALL CATCH BASIN TYPE 1 PER COR STD PLAN 200.00. 14 INSTALL 4' X 4' FILTERRA. SEE DRAINAGE DETAIL SHEETS. 18 REPLACE GRATE WITH SOLID LID PER COR STD PLAN 204.10 AND ADJUST TO GRADE. 24 EQUIP NEW FILTERRA WITH A FILTERRA THROAT OPENING WITH EXTENDED FLUME TO AVOID CONFLICT WITH EXISTING SD. 1 CONNECT TO EXISTING CATCH BASIN OR MANHOLE. 25 POWER TO BE RELOCATED. GENERAL NOTES: 1.SEE CDD SHEETS FOR DRAINAGE DETAILS. 2.SEE CRY SHEETS FOR TYPICAL ROADWAY SECTIONS. 3.SEE CXP SHEETS FOR DEMOLITION AND REMOVAL PLANS. 4.SEE CPP SHEETS FOR PAVING PLANS. 5.SEE UCP SHEETS FOR UTILITY PLANS. 6.EXISTING FACILITIES TO BE PROTECTED-IN-PLACE UNLESS OTHERWISE NOTED. 7.FOR PROPOSED IMPROVEMENTS NOT SHOWN, SEE PAVING, TRAFFIC, AND UTILITY SHEETS.SW 7TH ST CONTRACT UNIT DESCRIPTION 5 CIVIL DRAINAGE PLANS RAINIER AVE S 405-CDP503 25 0 1" = 40' No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:01/31/22 | 5:35 PM | USMB682252C:\BMS\D0342984\BRT-405-CDP500.DWGBRT-405-CDP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 N SCALE IN FEET 0 4020 8040 (1" = 40') S G RAD Y W A Y RAINIER AVE S HARDI E A V E S W FLOW FLOW EX CURB EX GUTTER 4.0' INLET OPENING 13.0' CONCRETE DEPRESSED GUTTERFLOWEX GUTTER EX CURB 2 B - CONNECT PIPE TO BYPASS STRUCTURE 6"Ø OUTLET PIPE A,C -4.0'4 3.54'INV. TO TOPCLEANOUT COVER TREE GRATE AND FRAME MULCH LAYER 6"Ø OUTLET PIPE (LOCATION VARIES) FILTERRA ENGINEERED MEDIA PERFORATED UNDERDRAIN UNDERDRAIN STONE PROVIDED BY FILTERRAINTERNAL JOINT, TYP DEPRESSED GUTTER AND THROAT OPENING 4.0' TRANSITIONAL DEPRESSED GUTTER 5.0' FULLY DEPRESSED GUTTER SEE DETAIL 2 THIS SHEET 4.0' TRANSITIONAL DEPRESSED GUTTER EX CURB THROAT OPENING TRANSITIONAL CURB 0.5'FILTERRA UNIT (BEHIND) TRANSITIONAL CURB 0.5'EX GUTTER EX CURB EX GUTTER 0.5'EX PAVEMENT 8" PRECAST TOP SLAB (FILTERRA UNIT) INLET TRAY (FILTERRA UNIT) TO BE INSTALLED BY FILTERRA CREW AT ACTIVATION PRECAST BOX WALL (FILTERRA UNIT) DEPRESSED GUTTER AND THROAT OPENING STANDARD 90° NOSING (FILTERRA UNIT) #4 DOWEL BARS @ 12" O.C. (FILTERRA UNIT) EX CURB AND GUTTER (BEHIND) THROAT OPENING ELEVATION 2 - 1.0'1.0'0.5'1.0'0.5' 1.5'1.0'0.5'SCALE IN FEET 0 (CUSTOM) 2 1 2 4 CONTRACT UNIT DESCRIPTION 5 CIVIL DRAINAGE DETAILS SOUTH RENTON TC AND RAINIER AVE S 405-CDD501 26 ---- AS NOTED---- ---- ---- ----No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:01/31/22 | 5:36 PM | USMB682252C:\BMS\D0342984\BRT-405-CDD500.DWGBRT-405-CDD500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 STANDARD FILTERRA UNIT WITH OFF-LINE BYPASS SCALE: 1"=2' 1 - FILTERRA UNIT WITH PERFORATED UNDERDRAIN SCALE: 1"=2' A - CONCRETE DEPRESSED GUTTER SCALE: 1"=2' B - DEPRESSED GUTTER AND THROAT OPENING SCALE: 1"=1' C - DEPRESSED GUTTER AND THROAT OPENING DETAIL SCALE: 1"=1' 2 - GENERAL FILTERRA CONSTRUCTION NOTES 1.FILTERRA UNIT TOP ELEVATION AND THROAT OPENING ELEVATIONS ARE APPROXIMATE. CONTRACTOR TO FIELD VERIFY FILTERRA UNIT ELEVATIONS AND SET FILTERRA UNIT ELEVATIONS TO ACHIEVE REQUIRED GRADES FROM EXISTING GUTTER. 2.IF THE FILTERRA IS STORED BEFORE INSTALLATION, THE TOP SLAB MUST BE PLACED ON THE BOX USING THE 2X4 WOOD PROVIDED, TO PREVENT ANY CONTAMINATION FROM THE SITE. ALL INTERNAL FITTINGS SUPPLIED (IF ANY), MUST BE LEFT IN PLACE AS PER THE DELIVERY. 3.THE UNIT SHALL BE PLACED ON A COMPACTED SUB-GRADE WITH A MINIMUM 6-INCH CSTC. THE UNIT IS TO BE PLACED SUCH THAT THE UNIT AND TOP SLAB MATCH THE GRADE OF THE CURB IN THE AREA OF THE UNIT. COMPACT UNDISTURBED SUB-GRADE MATERIALS TO 95% OF MAXIMUM DENSITY AT +1 TO 2% OF OPTIMUM MOISTURE. UNSUITABLE MATERIAL BELOW SUB-GRADE SHALL BE REPLACED TO THE ENGINEER'S APPROVAL. 4.OUTLET CONNECTIONS SHALL BE ALIGNED AND SEALED TO MEET THE APPROVED DRAWINGS WITH MODIFICATIONS NECESSARY TO MEET SITE CONDITIONS AND CITY STANDARDS. 5.ONCE THE UNIT IS SET, THE INTERNAL WOODEN FORMS AND PROTECTIVE MESH COVER MUST BE LEFT INTACT. REMOVE ONLY THE TEMPORARY WOODEN SHIPPING BLOCKS BETWEEN THE BOX AND THE TOP SLAB. THE TOP LID SHOULD BE SEALED ONTO THE BOX SECTION BEFORE BACKFILLING, USING A NON-SHRINK GROUT, BUTYL RUBBER OR SIMILAR WATERPROOF SEAL. THE BOARDS ON TOP OF THE LID AND BOARDS SEALED IN THE UNIT'S THROAT MUST NOT BE REMOVED. THE SUPPLIER (AMERICAST OR ITS AUTHORIZED DEALER) WILL REMOVE THESE SECTIONS AT THE TIME OF ACTIVATION. BACKFILLING SHOULD BE PERFORMED IN A CAREFUL MANNER, BRINGING THE APPROPRIATE FILL MATERIAL UP IN 6" LIFTS ON ALL SIDES. PRECAST SECTIONS SHALL BE SET IN A MANNER THAT WILL RESULT IN A WATERTIGHT JOINT. IN ALL INSTANCES, INSTALLATION OF FILTERRA UNIT SHALL CONFORM TO ASTM SPECIFICATION C891 "STANDARD PRACTICE FOR INSTALLATION OF UNDERGROUND PRECAST UTILITY STRUCTURES", UNLESS DIRECTED OTHERWISE IN CONTRACT DOCUMENTS. 6.THE CONTRACTOR IS RESPONSIBLE FOR INLET PROTECTION/SEDIMENT CONTROL AND CLEANING AROUND EACH FILTERRA UNIT. 7.ACTIVATION OF THE FILTERRA UNIT IS PERFORMED ONLY BY THE SUPPLIER. CONTRACTOR IS RESPONSIBLE FOR FILTERRA INLET PROTECTION AND SUBSEQUENT CLEAN OUT COST. THIS PROCESS CANNOT COMMENCE UNTIL THE AREA TRIBUTARY TO THE UNIT IS FULLY STABILIZED AND CLEANED (FULL LANDSCAPING, GRASS COVER, FINAL PAVING AND STREET SWEEPING COMPLETED), NEGATING THE CHANCE OF CONSTRUCTION MATERIALS CONTAMINATING THE FILTERRA SYSTEM. CARE SHALL BE TAKEN DURING CONSTRUCTION NOT TO DAMAGE THE PROTECTIVE THROAT AND TOP PLATES. CONSTRUCTION NOTES CONTRACTOR SHALL SAWCUT AND REMOVE EXISTING CURB AND GUTTER AS NECESSARY TO INSTALL FILTERRA UNIT AND TRANSITIONAL CURB. CONTRACTOR SHALL CAST IN PLACE NEW CEMENT CONCRETE DEPRESSED GUTTER AND TRANSITIONAL CURB AS NEEDED. DIMENSIONS SHOWN ARE APPROXIMATE AND SHALL BE FIELD VERIFIED. NEW CURB AND GUTTER SHALL TRANSITION SMOOTHLY TO MATCH EXISTING GRADES AND FEATURES INCLUDING CURB, GUTTER, AND PAVEMENT. ORIENTATION OF FILTERRA UNIT SHOWN IS FOR LEFT SIDE OUTLET. RIGHT SIDE OUTLET VERSION IS AN EXACT MIRROR IMAGE. LEFT AND RIGHT SIDE ORIENTATION IS BASED ON LOOKING TOWARDS THE UNIT FROM THE STREET CENTERLINE. OUTLET PIPE LOCATION VARIES, SEE DRAINAGE PLAN SHEETS. CONTRACTOR TO BEND FILTERRA UNIT DOWEL BAR AS NEEDED TO INSTALL CAST IN PLACE DEPRESSED GUTTER AND THROAT OPENING. INTERIOR FEATURES OF FILTERRA UNIT ARE TYPICALLY PROVIDED BY MANUFACTURER AND ARE SHOWN FOR REFERENCE ONLY. STATION/OFFSET LOCATIONS AND NORTHING/EASTING COORDINATES FOR FILTERRA UNITS ARE FOR MIDPOINT OF THROAT OPENING AT OUTER FACE OF PRECAST WALL. UNIT ALIGNMENT IS ORIENTED PARALLEL TO CURB LINE. LOCATIONS ARE APPROXIMATE, CONTRACTOR TO FIELD VERIFY. THROAT CLEARANCE SHALL BE 4" MIN AND 6" MAX. SEE FILTERRA UNITS SCHEDULE FOR THROAT OPENING ELEVATION. TABLE ELEVATION IS APPROXIMATE, CONTRACTOR TO FIELD VERIFY. SCALE IN FEET 0 (CUSTOM) 1 0.5 1 2 1 2 3 4 5 6 7 8 99 3 6 3 6 3 FILTERRA UNITS SCHEDULE ID #STATION/ OFFSET OUTLET SIDE THROAT OPENING ELEVATION PLANT SELECTION 1 405-C-RainierS 16+17.5, 1.3' LT L 25.2' CHOKEBERRY, BLACK (ARONIA MELANOCARPA) 2 405-C-RainierS 16+21.7, 52.1' RT L 23.5' CHOKEBERRY, BLACK (ARONIA MELANOCARPA) 3 405-C-RainierS 18+02.6, 52.6' RT R 24.0' CHOKEBERRY, BLACK (ARONIA MELANOCARPA) 4 405-C-RainierS 15+34.7, 53.5' RT L 24.0' CHOKEBERRY, BLACK (ARONIA MELANOCARPA) 9 37 BOTTOM WIDTH PER PLAN 3" COMPOST BLANKET (CABS) 3 (TYP) 1 1/8"SEE NOTE 4 PAVEMENT PER DESIGN DOCUMENTS 10"10"10"FLOW SPREADER AT HEAD OF SWALE QUARRY SPALLS CATCH BASIN SCALE IN FEET 0 (CUSTOM) 2 1 2 4 CONTRACT UNIT DESCRIPTION 5 CIVIL DRAINAGE DETAILS SOUTH RENTON TC 405-CDD502 27 ---- AS NOTED---- ---- ---- ----No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:01/31/22 | 5:36 PM | USMB682252C:\BMS\D0342984\BRT-405-CDD500.DWGBRT-405-CDD500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 SCALE IN FEET 0 10 20510 (1" = 10') COMPOST AMENDED BIOSWALE (CABS) SCALE: 1"=2' 3 - 1.TRENCH DRAIN TO BE S200K POWERDRAIN - LOAD CLASS F AS MANUFACTURED BY ACO-POLYMER PRODUCTS, INC. 2.MINIMUM CONCRETE STRENGTH OF 4,000 PSI. CONCRETE SHOULD BE VIBRATED TO ELIMINATE AIR POCKETS. 3.EXPANSION AND CONTRACTION CONTROL JOINTS AND REINFORCEMENT ARE REQUIRED. 4.THE FINISHED LEVEL OF THE CONCRETE SURROUNDING THE GRATE MUST BE APPROX. 1 8" ABOVE THE TOP OF THE CHANNEL EDGE. 5.GRATES SHALL BE SECURED USING 'POWERLOK' BOLTLESS LOCKING SYSTEM. 6.THE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. TRENCH DRAIN SCALE: NTS 5 - TRENCH DRAIN SPECIFICATION CLAUSE 1.CABS LENGTH, SLOPE, AND BOTTOM WIDTH PER PLAN. 2.INSTALL LEVEL SPREADERS PER COR STANDARD DETAIL 217.50 EVERY 50 FT OF SWALE LENGTH. 3.INSTALL FLOW SPREADER WITH CONCRETE SUMP AT THE BEGINNING OF SWALE PER DETAIL 4 THIS SHEET. CABS NOTES: CABS FLOW SPREADER WITH CONCRETE SUMP SCALE: 1"=2' 4 - FLOW CONTROL RISER LENGTH, SEE SCHEDULE 0.5' C/L IE IN IE OUT 0.5' RIM/FG PRE-FILTER CARTRIDGE C/L C/L INLET PIPE SEE NOTES OUTLET PIPE SEE NOTES B/C - A - WETLAND MEDIA BED DRAIN DOWN FILTER PERIMETER VOID AREA PRE-FILTER CARTRIDGE PLANT ESTABLISHMENT MEDIA WIDTH, SEE SCHEDULE 0.5' C/L 0.5' RIM/FG HATCH 0.71'VEGETATION 0.5'HEIGHT, SEE SCHEDULEOUTLET PIPE WIDTH, SEE SCHEDULE 0.5' C/L 0.5' RIM/FG HATCH 0.71'SOLID LID HEIGHT, SEE SCHEDULE0.5'OUTLET PIPE SCALE IN FEET 0 (CUSTOM) 2 1 2 4 CONTRACT UNIT DESCRIPTION 5 CIVIL DRAINAGE DETAILS SOUTH RENTON TC 405-CDD503 28 ---- AS NOTED---- ---- ---- ----No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:01/31/22 | 5:36 PM | USMB682252C:\BMS\D0342984\BRT-405-CDD500.DWGBRT-405-CDD500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 MODULAR WETLAND ELEVATION SCALE: 1"=2' A - 1.MODULAR WETLAND SHALL BE MANUFACTURED BY BIO CLEAN, INC. 2.MODULAR WETLAND WITHOUT PLANTS SHALL HAVE SOLID CONCRETE COVER AND ACCESS HATCHES MEETING HS20-44 LOADING. 3.INTERNAL VAULT DIMENSIONS. MODULAR WETLAND GENERAL NOTES: MODULAR WETLAND PLAN SCALE: 1"=2' 6 - MODULAR WETLAND SECTION SOLID LID SCALE: 1"=2' C - MODULAR WETLAND SECTION WITH VEGETATION SCALE: 1"=2' B - MODULAR WETLAND UNITS SCHEDULE UNIT # STATION/ OFFSET LENGTH (FT) (SEE NOTE 3) WIDTH (FT) (SEE NOTE 3) HEIGHT (FT) INLET PIPE SIZE (IN) INLET PIPE IE OUTLET SIDE OUTLET PIPE SIZE (IN) OUTLET PIPE IE PLANT SELECTION 1 405-C-Rainier- Lake-Drwy 10+24.9, 17.0' RT 6.3 4.0 5.0 8 22.8 R 8 20.7 CHOKEBERRY, BLACK (ARONIA MELANOCARPA) 2 405-C- CenterIslandS 17+27.7, 59.0' LT 6.3 4.0 7.0 12 22.9 L 12 20.8 NO PLANTS. USE SOLID COVER. SEE NOTE 2. CHARGER CHARGER CHARGER CHARGER CHARGER CHARGER CHARGER TRANSFORMER CHARGER SWITCHGEAR CHARGER CHARGER CHARGER IT CHARGER16+0018+00750 + 0 0 750 + 0 0 152+00 154+00 156+00 158+00 160+00 11+47 10+00 19+ 2 6 10+00 12+ 0 0 14+0 0 16+00 18+0 0 17+65 10+00 12+ 0 0 14+00 16+00 9+5 1 10+ 0 0 12+ 0 0 14+00 16+00 18+00 18+30 14+70 9+75 10+0012+0014+00 SDSD SD SD SDSDSD SD SD SDSDSDSDSDSDSD SD SD SD XXX X X X X XXX X CONC CONC SIGN DEBRISRAINIER AVE S SBRAINIER AVE S NBRAINIER AVE S NBSR-167 NBSR-167 SBGRADY W A Y E B GRADY W A Y E B GRADY W A Y E BLAKE AVE SLAKE AVE SCONC ASPH ASPH ASPH ASPH ASPH ASPH ASPH ASPH ASPHASPH ASPH ASPH ASPH ASPH ASPH E 1,298,300E 1,298,400E 1,298,500E 1,298,600E 1,298,700E 1,298,700E 1,298,800E 1,298,800E 1,298,900E 1,298,900E 1,299,000N 175,400 N 175,500 E 1,298,500E 1,298,600UT UT UT UT UT H H H H H VLT VLT VLT VLT VLTS VLTSDSS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSDSS SDSD30" CONC 30" C O N C 27" CONC 27" CONC 27" CONC 24" CMP12" CONC4" CONC6" DI12" CPP12" CPP6" CONC 8" VC 8" CONC18" CONC HH BROADBAND VAULT 5" TREE 11' DLN 5" TREE 11' DLN 11" STUMPCONC BENCHCONC BENCH YIELD A R T W O R KLANDSCAPINGCONCDRW35 MPH 5" TREE 8' DLN 5" TREE 11' DLN 5" TREE 11' DLN 6" TREE 12' DLN 5" TREE 11' DLN 5" TREE 13' DLN 6" TREE 12' DLN 6" TREE 13' DLN DRW5" TREE 15' DLN 6" TREE 14' DLN 8" TREE 16' DLN 5" TREE 12' DLN LANDSCAPING6" TREE 14' DLN SWMULTIPLE 6" TREES 35' DLN 5" TREE 8' DLN 5" TREE 11' DLN ASPHASPHASPH CONC SEA M S ( T Y P )LANDSCAPINGC&GC&GOE OE OE OE OE OE OE OE ASPH SW SW SW LANDSCAPINGDRWDRWEEEE E E EE WV3WVWVWV 3WV WVWV WV3WV HHHHHHHHHHHHHHHH HH HH HH HH 3HH HH HH HH HH HH HH HH 4ELEC VLT 2ELEC VLT2IRRG GVGVWMHH MW WM ELEC VLT E HH 2WV HH ELEC VLT HH HH E E W EWWWWWWWWWWWWWWWEEEEEWM G E E E E T T T T T E E E EEE EEE E E EEE E E E EEEEW 3TRAFFIC CONTROL CABINETS CO WW WWWFO FOFOFOFO FO FO FOFO WW WW W MW GV GV GM WM WM WM WM WV WV 3W V WV WM MWW VLTMW 2VLTS HH TEEWWTTE E TTTTT EEEEEEE EE E T T T TTTT TTE E EEEEE E E E E TS HHHH HH HH HH HH TMH VLT TS VLT HH VLT UNKNO W N U T I L 2" DROP 2" DROP HH GM DETECTO R LOOP (TY P ) DETECTO R LOOP (TY P ) G EEE EE E E E E E E E E E E E E E E E E E E E EE E E E E E E E E E EGFOFOFOFOFOFO FO FO FO FO F OFO FO FO FO FO FOFO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FOFOFOFO FOFOFO W W W W W WW W W W WWWWWWWSD SD SD SDSD W W WFO FOFOFO FOFOFO FO FO FO FOFO FOFO FO S D S D S D S D SD SDSD SDSD SDSDSDSDSDSDSDSDSDSDSD SDSDS D SDSDSD SD SD SD SD SD SD SD SD SD SD SD SDSDSD SD SD SD S S FOFOEEEEEEE EEEEEFO FO FO FO FO FO FO FO FO FO FO FO FO FOFOFO FO HH HH 16" CMP//////////// ////// / //////////////////// //////// / / ///////////////////////// / / / / / / / ////////// //////////////////////////////////////////////////////////////////////////// X X X X X X X X X XXXXXX6' CLEF X X X X 6' TEMP CLE F X X X X XXX XXX 6' TEMP CLE F XX6' TEMP CLEF XXX6' T EMP C LEF SOUND COLLISION CENTER X X X X X X8' CLEF//////// ASPH ASPH ASPH X X X X X X X X X X X X X XXXXX5.5' CLEF PP PP PP SIGN 6" TREE 19' DLN4" TREE 10' DLN LOAD LIMIT USE CROSSWALK SW PARK & RIDE USE CROSSWALK X 2' FNC C&G C&GC&GGATE// //// / / ///6' CLEFASPH 5.5' CLEF 6' CL E F BLDG EQUIP GAZEBO CONC ELEC EQUIP SIGN ON CONC BASE SIGN ON CONC BASE SIGN ON CONC BASE SIGN ON CONC BASE SOUND COLLISION CENTER LANDSCAPINGLANDSCAPINGLANDSCAPING LANDSCAPINGLANDSCAPING2 11" TREES 32' DLN MULTIPLE 5-7" TREES 20' DLN SWSWSWSWSW LANDSCAPING MAZDA SIGN GRASS C&G SW SW SW C&G ///////////////////////////////////////////////////////////////// SIGN ON CONC BASE SIGN ON CONC BASE 5" TREE 8' DLN 4" TREE 7' DLN CONC BASE REMOVED LT 4 BLRD 3 BLRD 3 BLRD 2 BLRD PM XXXXX6' TEMP CLEF6' CLEF WELCOME TO TRUCK CITY SIGN SIGN 2 BLRD//////////// //// //////////////////////// / ///// / / / ///////////////// / / / ///////////// /////////////////////////////////////////////////////////////////////OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE OE OE OE OE OE OE OE OE OE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE OE OE OE OE OE OE OE OE OE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE////////////////// //////////////////////////////////////////////////////////////////////////////////////////////////////////////// ///////////// / / / / //////////// / / / / 3 BLRD WHEEL STO P S ( T Y P )WHEEL STOPS (TYP)6' TEMP CLEFSIGN ON CONC BASE BLD EQUIP SIGN POST ON CONC BASE WHEEL STOPS (TYP) 6' CLEF OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE PIV GAT E STORAGE SHED MISC VALV SHELTER CANOPY EOPEOPEOPEOP15 MPH SIGN BLDG BLDG BLDG BLDG SD 12" RCP 8" CONC 8" CONC 4" CONC30" CPP24" CPP12" CP P 18" DI24" CPPGGFO FO FO FO EEEEEEEEEEEEE E E E E E E E OEOEOEOEOEOESL SL FO FO FO FOFOFOEFOFOFO FOFOFOFOFOFOFOWWWSSSSFO SSSSSSSSSSSSSSSSSSWWFOSSSSSSSSCOMCAST COMCASTCOMCASTCOM C A S T COMCAST COMCAST COMCAST COMCAST COMCA STCOMCAST COMCASTCOMCAS T COMCASTCOMCASTCO M C A S T F O COMCAST CENTURYLINK FOCENTUR Y L I N K F O CENTURY L I N K F O CENTUR Y L I N K F O CENTURY L I N K F O CENTURY L I N K F O CENTURY L I N K F O CENTURYLINK FO3-PSE 2-PSE 2-PSE 2-PSE 2-PSE 2-PSE 2-PSE 2-PSE 2-PSE PSE PSE PSEPSEPSEPSEPSE PSE PSE PSEPSEPSEPSERENTONRENTONR EN TO NRENTONRENTON RENTONRENTONRENT ON WSDOT FOWSDOT FOWSDOT FO 2-ZAYO F O 2-ZAYO F O 2-ZAYO FO 2-ZAYO F O 2-ZAYO FOPSE G A S PSE GAS PSE GASPS E G A S PSE GAS PSE GASPSE GAS PSE GASPSE GAS POTHOLE SRTC-19B GND=26.86 1" PVC PWR TOP OF CND=25.11 POTHOLE SRTC-19A GND=26.86 6" DI W TOP OF PIPE=23.66 POTHOLE SRTC-26 GND=26.60 2 x 1" PVC PWR TOP OF CND=24.67 POTHOLE SRTC-12 GND=27.53 9 DIRECT BURIED PWR CND TOP CENTER OF CABLES=25.76 POTHOLE SRTC-16 GND=27.00 2" PVC COMM TOP OF PIPE=24.38 POTHOLE SRTC-15 GND=27.33 2" STW GAS TOP OF PIPE=24.12 EEEE POTHOLE SRTC-21 GND=26.51 8" DI W TOP OF PIPE=23.70 POTHOLE SRTC-27 GND=26.70 8" DI W TOP OF PIPE=23.86WW POTHOLE SRTC-24 GND=27.59 2" STW GAS TOP OF PIPE=25.60 POTHOLE SRTC-25 GND=27.77 2-PVC CND PWR TOP OF CND=26.84 POTHOLE SRTC-28 GND=26.93 2" PVC COMM TOP OF CND=24.82 POTHOLE SRTC-29 GND=26.83 6" W TOP OF PIPE=23.59 POTHOLE SRTC-30 GND=26.69 8" DI W TOP OF PIPE=21.81 POTHOLE SRTC-32 GND=26.76 5 DIRECT BURIED PVC PWR CND 28" WIDE TOP CENTER OF PIPES=22.87 POTHOLE SRTC-33 GND=26.45 7-DIRECT BURIED PWR CND 6" WIDE TOP CENTER OF CND=24.73 POTHOLE SRTC-37 GND=26.13 DNF W POTHOLE SRTC-37A GND=26.17 DNF W E E E E TT T T T T T T T T T GGGGG G G GGGGGG G GGGPOTHOLE SRTC-35 GND=26.42 DNF W POTHOLE SRTC-31 GND=26.79 2" PVC COMM TOP OF PIPE=24.71 POTHOLE SRTC-20 GND=25.37 8" STEEL W TOP OF PIPE=22.49 POTHOLE SRTC-26A GND=27.42 2" STW GAS TOP OF PIPE=25.20 POTHOLE SRTC-11 GND=28.00 0.5" CABLE COMM TOP OF CND=25.45 E E EEE E E EEE E W W W W W G G G EEW E EE EEEE E E EEWWWW E EE UTIL VLT HH HH HH E EE E UNKNOWN U T I L I T Y UTIL VLT FO VLTCCCCCFOFOFOFOFOFOFOFOFOFOTTTTTTEFOFOET T TEGGFOFOFOC EFOPOTHOLE 39 GND EL=27.28 2-6" PWR CND TOP OF CND EL=24.10 POTHOLE 38 GND EL=27.46 1" COMM DIRECT BURIED CABLE TOP OF CABLE EL=24.38 POTHOLE 40 GND EL=27.33 DUG 5' DID NOT FIND POTHOLE 13 GND EL=29.05 2" POWER CND TOP OF CND EL=26.84 POTHOLE 14 GND EL=25.96 2" POWER CND TOP OF CND EL=23.96 POTHOLE 45 GND EL=24.06 2" POWER TOP OF CND EL=22.28 POTHOLE 48 GND EL=24.39 6" STORM PIPE TOP OF PIPE EL=22.13 POTHOLE 48B GND EL=24.38 4" COMM CND TOP OF CND EL=21.67 POTHOLE 49 GND EL=24.52 2 x 2" POWER TOP OF CND EL=22.63 POTHOLE 53 GND EL=27.04 6" GAS TOP OF PIPE EL=22.41 POTHOLE 50 GND EL=26.79 6"&4"&2-2"&1" POWER CND TOP OF CND EL=25.31 IRRG POTHOLE 43 GND EL=26.98 DUG 6' DID NOT FINDPOTHOLE 42 GND EL=26.98 2-6" POWER CND GND EL=23.99 POTHOLE 01 GND EL=29.05 4" FIBER OPTIC TOP OF CND EL=27.01 POTHOLE 14A GND EL=25.96 4" COMM CND TOP OF CND EL=24.13 POTHOLE 51 GND EL=27.04 4 x 4" FIBER OPTIC TOP OF CND EL=22.66E POTHOLE 49A GND EL=24.52 2 x 4" COMM TOP OF CND EL=22.60 POTHOLE 48A GND EL=24.38 2" POWER CND TOP OF CND EL=21.96 POTHOLE 46 GND EL=24.06 4" FIBER OPTIC TOP OF CND EL=22.12 POTHOLE 44 GND EL=26.98 3-4" FIBER OPTIC GND EL=24.05 POTHOLE 41 GND EL=27.28 3-4" FIBER OPTIC TOP OF CND EL=24.06 BOREHOLE GA-10 EL=26.31 BOREHOLE SB-1 EL=27.17 BOREHOLE GA-14 EL=26.36 BOREHOLE EL=25.43 BOREHOLE GA-1 EL=25.09 BOREHOLE GA-2 EL=25.98 MW EL=25.08 BOREHOLE RW10 EL=25.30 MW GWMW-3 EL=26.16 MW GWMW-4 EL=26.41 MW GWMW-2 EL=26.06 BOREHOLE GA-3 EL=25.97 MW GWMW-1 EL=26.60 BOREHOLE GA-4 EL=26.06 BOREHOLE SH-5 EL=26.22 BOREHOLE GA-8 EL=26.69 BOREHOLE GA-5 EL=27.71 BOREHOLE GA-7 EL=27.67 BOREHOLE GA-6 EL=27.90 BOREHOLE SB-2 EL=27.29 BOREHOLE GA12 EL=26.45 BOREHOLE GA-13 EL=26.06 BOREHOLE P-15 EL=25.66 1 x 2" & 2 x 6" POWER CND FO FO FO FO E E E E E E E E FO FO FO FO FO FO FO FO REMOVE EXISTING LIGHT FIXTURE, POLE, AND FOUNDATION / / / / / / / / / / / / / / / / / / / / / / / / // / // / // / // / / / / / / / / / / / / / / / / / / / / / / / / / // / // / / / / / / / / / / / / / / / / / / / / / / / / / / / / // / // / / / / / / / / / / / / / / / / / / / / / / / / / // / // //////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / //////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// //////////////////////////////////////////////// // /////// /// / / / / / / / / / / / / / / / / / / / // / / / / / / // / // / // / / //// / // / / /////////////////////////////////////////////// ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// ////////////////////////////////////////////////////// ///////////////////////////////////////////////////////////// / / / / / / / / / //////////////////////// W W////////////////////////////////////////////////////////////////////////////////////////////////////////// /////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// /////////////////////////////////////////////////////////////////////////////////////// / / ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////WWWW W W W W W W W WW W W W W W W W SS//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// /// /// //////////// ////////////////////////////////////////////////SS SS SS SS SS SSSS SS ///////////////////////////////// W W W W W W W W W W W W W W W W W W W /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// /// /// /// /// //////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////WWSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS WW////////////////////////////////////////////////WWWWWWWWW 405-C-Gr a d y W 405 - C - H a r d i e S W S GRAD Y W A Y LAKE AVE SRAINIER AVE S////////////////////////////////////////////////////////////// PROPERTY LINES, TYP CONNECT TO EXISTING LINE NEW 12" WATER LINE (CAPPED FOR FUTURE CONNECTION) NEW 12" WATER LINE RPDB FOR FIRE WATER SUPPLY BOX APPROXIMATELY 36" x 82" PROTECT AND MAINTAIN EXISTING FIBER OPTIC LINE CONNECT TO NEW YARD HYDRANT REMOVE EXISTING VAULT REMOVE EXISTING TRANSFORMER ADJUST HANDHOLE TO GRADE CONNECT TO NEW YARD HYDRANT CONNECT TO NEW YARD HYDRANT CONNECT TO NEW YARD HYDRANT CONNECT TO NEW YARD HYDRANT REMOVE EXISTING POLE AND FIXTURE CONNECT TO EXISTING ELECTRICAL SYSTEM NEW TRANSFORMER REMOVE EXISTING LIGHT FIXTURE, POLE, AND FOUNDATION REMOVE EXISTING LIGHT FIXTURE, POLE, AND FOUNDATION 6" PVC, CONNECT TO NEW TOILETS REMOVE EXISTING LIGHT FIXTURE, POLE, AND FOUNDATION NEW SS MANHOLE CONNECT TO EXISTING MANHOLE ADJUST HANDHOLE TO GRADE CONNECT EXISTING WATER LINE TO NEW WATER LINE ADJUST EXISTING GAS VALVE REMOVE EXISTING HANDHOLE REMOVE EXISTING GAS VALVES REMOVE EXISTING HYDRANT PROTECT EXISTING WATER LINE RELOCATE EXISTING HANDHOLE TO BACK OF WALK ADJUST HANDHOLE TO GRADE RELOCATE EXISTING LIGHT POLE, INSTALL NEW FOUNDATION AT BACK OF WALK REMOVE EXISTING TRANSFORMER ADJUST EXISTING HANDHOLES TO GRADE REMOVE EXISTING LIGHT FIXTURE, POLE, AND FOUNDATION REMOVE EXISTING LIGHT FIXTURE, POLE, AND FOUNDATION REMOVE EXISTING LIGHT FIXTURE, POLE, AND FOUNDATION REMOVE EXISTING LIGHT FIXTURE, POLE, FOUNDATION, AND ASSOCIATED HANDHOLE ADJUST EXISTING FACILITIES TO GRADE REMOVE EXISTING HANDHOLE 22.0'10.0'NEW SEWER MANHOLE INTERCEPT EXISTING SEWER LINE INTO NEW MANHOLE NEW 12" WATER LINE CONNECT TO EXISTING WATER LINE 18" SEWER LINE CONNECT TO EXISTING HYDRANT FUTURE GARAGE NEW 12" WATER LINE NEW SEWER MANHOLE ADJUST OR REMOVE EXISTING GAS VALVE REMOVE ELECTRICAL VAULT ADJUST EXISTING SEWER MANHOLES REMOVE OR ADJUST EXISTING COMM VAULT NEW SS MANHOLE RPDB FOR DOMESTIC WATER BOX APPROXIMATELY 26" x 74" REMOVE EXISTING HYDRANT REMOVE EXISTING LIGHT FIXTURE, POLE AND FOUNDATION REMOVE EXISTING LIGHT FIXTURE, POLE, FOUNDATION, AND ASSOCIATED HANDHOLE REMOVE EXISTING LIGHT FIXTURE, POLE, FOUNDATION, AND ASSOCIATED HANDHOLE ADJUST WATER VALVES TO GRADE N SCALE IN FEET 0 4020 8040 (1" = 40') CONTRACT UNIT DESCRIPTION 5 UTILITIES UTILITY COMPOSITE PLANS SOUTH RENTON TC 405-UCP501 29 ---- 1" = 40' HARDIE AVE SWNo.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/09/22 | 12:25 PM | DAVID.HARRISC:\BMS\WSP-PB-US-PW-02\DAVID.HARRIS@PERTEET.COM\D0342984\BRT-405-UCP500.DWGBRT-405-UCP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELI MI N A RY 405 R. GORMAN 02/11/2022 NOTES: UTILITY QUALITY LEVEL A: PRECISE HORIZONTAL AND VERTICAL LOCATION OF UTILITIES OBTAINED BY THE ACTUAL EXPOSURE (OR VERIFICATION OF PREVIOUSLY EXPOSED AND SURVEYED UTILITIES) AND SUBSEQUENT MEASUREMENT OF SUBSURFACE UTILITIES, USUALLY AT A SPECIFIC POINT. MINIMALLY INTRUSIVE EXCAVATION EQUIPMENT IS TYPICALLY USED TO MINIMIZE THE POTENTIAL FOR UTILITY DAMAGE. A PRECISE HORIZONTAL AND VERTICAL LOCATION, AS WELL AS OTHER UTILITY ATTRIBUTES, IS SHOWN ON PLAN DOCUMENTS. ACCURACY IS TYPICALLY SET TO 15-MM VERTICAL AND TO APPLICABLE HORIZONTAL SURVEY AND MAPPING ACCURACY AS DEFINED OR EXPECTED BY THE PROJECT OWNER. UTILITY QUALITY LEVEL B: INFORMATION OBTAINED THROUGH THE APPLICATION OF APPROPRIATE SURFACE GEOPHYSICAL METHODS TO DETERMINE THE EXISTENCE AND APPROXIMATE HORIZONTAL POSITION OF SUBSURFACE UTILITIES. QUALITY LEVEL B DATA SHOULD BE REPRODUCIBLE BY SURFACE GEOPHYSICS AT ANY POINT OF THE DEPICTION. THIS INFORMATION IS SURVEYED TO APPLICABLE TOLERANCES DEFINED BY THE PROJECT AND REDUCED ONTO PLAN DOCUMENTS. UTILITY QUALITY LEVEL C: INFORMATION OBTAINED BY SURVEYING AND PLOTTING VISIBLE ABOVE-GROUND UTILITY FEATURES AND BY USING PROFESSIONAL JUDGEMENT IN CORRELATING THIS INFORMATION TO QUALITY LEVEL D INFORMATION. UTILITY QUALITY LEVEL D: INFORMATION DERIVED FROM EXISTING RECORDS OR ORAL RECOLLECTIONS. ALL EXISTING UTILITY INFORMATION DEPICTED AT QUALITY LEVEL B UNLESS OTHERWISE NOTED. UTILITIES IN BROWN COLOR DEPICTED AT QUALITY LEVEL D. PROPOSED UTILITIES: STORM PIPE, SEE DRAINAGE PLAN 405-CDP501, 405-CDP502, 405-CDP503 ELECTRICAL CONDUIT/WIRE, SEE STREET LIGHTING PLAN 405-ELP501, 405-ELP502 FOR PAVING INFORMATION, SEE PAVING PLAN 405-CPP501, 405-CPP502 GENERAL NOTES: //////////FACILITY TO BE ABANDONED LEGEND ///////////////FACILITY TO BE REMOVED 10+09 12+0 0 14+00 16+00 18+00 20+00 22+00 747+ 0 0 748+ 0 0 750+00750+00150+00 1 5 2 + 0 0 248+001011+47 10+00 12+0010+00 12+009+5110+0012+00405-C -SW7THSTSW 7TH ST X X CONCS IG N S IGN SIGN S I GN RAINIER AVE S SB RAINIER AVE S NB RAINI E R A V E S N B RAINI E R A V E S S B HARD I E A V E S W SR-167 NB SR-167 SB A S P H ASP H A S PH A S PH ASPH A S PH ASP H A SP H A S PH N 1 7 4 , 9 0 0 N 1 7 5 , 0 0 0 N 1 7 5 , 1 0 0 N 1 7 5 , 2 0 0 N 1 7 5 , 3 0 0 E 1,29 8 , 0 0 0 E 1,29 8 , 1 0 0 E 1,29 8 , 2 0 0 E 1,29 8 , 3 0 0 E 1,29 8 , 4 0 0 E 1,29 8 , 5 0 0N 1 7 5 , 6 0 0 UT U T HHHH HV L T V L T V L T VL T VL T S V L T S V L T E 1,29 8 , 2 0 0 N 1 7 5 , 6 0 0 / / //////BU S SHE L T ER T R A S HBIN B U SSIGN TRA SHBIN B U S S IG N P OW ERCAB I N E TSW D RW 6 " TRE E ± 1 2 ' D L N 4 " TRE E ± 2 2 ' D L N B U SSIG N 6 " TRE E ± 1 0 ' D L N /// BU S SHE L TER TR ASH B I N Y I E L D 6 " T R E E ± 1 6 ' D LN 6 " T R EE ± 1 8 ' D LN 6 " TR EE ± 1 2 ' D LN 8 " T R E E ± 1 4 ' D LN 8 " T R EE ± 2 0 ' D LN 6 " TR E E ± 1 4 ' D LN 6 " TRE E ± 1 4 ' D L N 6 " TR E E ± 1 4 ' D L N 6 " T R EE ± 1 4 ' D LN C&G C &G C&G C&G SW SW SW DRW DRW SW SW DRW EXTR CO N C CURB EXTR CO N C C U R B EXTR CONC C U R B EXTR CO N C C U R B SD SD SD SD SD SDS S S S S S S S S S S S S SSSSSSSSSSSSS36" CM P 3 6 " D I 30 " C O N C 12" CO N C 6 " CO N C 6" C O N C 6" CONC6" PVC 6" DI12" DI6" PVC 12" C O N C 6" CONC 8" V C 8" CO N C 18" CONCH H BRO AD B AND V AU L T T TE TS- L TVL T S L H H H H L T H H TCHH FO FOMH FO F OMH FO FOMH T S L THH MWL T H H TMHICVICV 2W V TMH GV WVWVWV L THHICVICVICVICVICVHH WV WV ELEC VLT HH ICVICV TS HH WM ELEC VLT LT HH WV ELEC VLT 2WM WV LT HH ELEC VLT LT HH WM ICV GVCONC BENCH YI E LD 1 1 " TRE E 2 7 ' D L N 1 4 " T R E E 2 4 ' D LN 4' WO O D F N CUS ECROSSW A L K CWG R A S S 3 7 " T R E E 4 0 ' D LN 4 3 " TRE E 4 5 ' D LN 3 2 " TRE E CONC BENCHCONC BENCHY I E LD ARTWORKLANDSCAPINGCONC DRW 3 5MP H 5 " TR EE 8 ' D LN 5 " T R E E 1 1 ' D LN 5 " T R EE 1 1 ' D LN 6 " T R EE 1 2 ' D LN 5 " T R E E 1 1 ' D LN 5 " TR EE 1 3 ' D LN 6 " T R E E 1 2 ' D LN 6 " T R E E 1 3 ' D LN DRW 5 " T R EE 1 5 ' D LN 6 " T R E E 1 4 ' D LN 8 " TR E E 1 6 ' D L N 5 " TR E E 1 2 ' D L N LANDSCAPING 6 " T R E E 1 4 ' D LN SW MUL T I P LE 6 " T R E E S 3 5 ' D LN 5 " T R E E 8 ' D LN 5 " T R E E 1 1 ' D LN ASPH ASPH C O N C S E A M S ( T Y P ) LANDSCAPI N G C&G C&G OE OE OE OE OE OE O E O EOEOEOEOEOEOEOE OE A S PH S W LANDS C A P I N G DRW DRW E CO EE E EE E E E WE E EE EE WV WV3WV WVWV3WVWV WV WV WV 3W VWVWVWV HH HH HH HH HH HH HH HHHHH H HH HHH H H H H HHH HHH H HHH H H H 3 H H HHHHHHH H HH HH HH H H H H H H E L E CVL T E LE C V L T ELEC V L T 4 E L E C V L T E L EC V L T E L E CVL T 2 E L E C V L T 3 IRRG 2 IRRG 2IRRG GV GV GV WM H H EEWE W W W W W W W W W W W W W W W EE E E E WMFO FO W WGGE EGFO FO FO E E EGG G G G G G G E E E E E E E E E E FO T T T FO FO FO FO FO FO FO E E E E E E E E E E E E E W E E FO FO FO E E EWTEEEW W W W W W WGGG G GGGG 3 T R A F F I CCON T R O LCA B INE T S COWWFO FO FOFOFOFOFOFOWW W WWMWGV WM3WVW VLT HHE E WWTTE EEE EE EEEE E T TTTT T T T T EEEEUNK N O W N U T I L 2 " DRO PGG EEE E E E E E E E E E E E E E E E E E E E E EE E E E E E EEEE EEEEE EE E E E E E E E E E EE EEEEE G G G G G G G GG GGG FO FO FO F O F O FO FO FO FO FO FOFOFOFOFOFO FO FOFOFO FO FO FO FO FOFOFOFO FO FO FO FOFO FO FO FOFOFOFO FOFOFOFO FOFO FO FOFOFO F O F O FO FO FO FO F O FO FO FO FO FOWWWW W W WW W W W W WWWSDSDSDSDSDSDSDSD SD SDFO FO FO FO FO FO FO FO FOFO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FOFO FO FO FO FOFO FO FO FO FO FO SD SDSD SD SD SD SD SD SD SD SD SD SD SDSD SD SD SD SD SD SD SD SD SDSDSD SDSDS D S DSSSSSS SSSSSSSSSSSSSSSSSSS S S S FO FO E EE E E E E E E E E E E E E E E EEEE E EEE E EEE EE E E E F O F O FOFOFOFOFOFOE E E FO FOFOFOFOFOFOFO FOFOFOFOFO FO6" CONCFOFO/// / / / / / / / ///// / / / //////////////// / / / /////////// / / / / ///// / ///////// / / /// / / / /////// /XXX X6' T E M P C L E FX X XX X X XXXX6' T E M P C L E F XX6 ' T EM P C L E F X XX6' TEMP CLEFSOUNDCOL L I S IONCEN T ER XXXX////// / / A S PH A S P H XXX6' CLEF G A Z E B O CON C E L EC EQ U I P S I GN O N CONC B AS E SO U N D CO L L I S IO N C EN TE R S IGN O NCONC B A S E 5 " T R EE 8 ' D LN 4 " T R EE 7 ' D L N CONC B A S E R EMO V E D L T ////////////////// / ///// / / / / / / / / ///////// /// ///////// / / /// / /// / / / / / / //////////////// / / / / / / //////// ///////// / // / / / / / / / / / / / /// / // / / / / / // / / / ////// 3 B L R D W H E E L S T O P S ( T Y P ) WHEEL S T O P S ( T Y P ) 6' TEM P C L E F S IG N ON C ONC B AS E D E TE C TOR L OOP ( T YP )OE OEOE S IG N P I V GATES T OR AG E S H ED M I S C V A L V B L D G SD30" CP P 24" CPP 12" C P P 18" DI 18" DI 12" CPP12" CPP 12" CPP 24" CPP E E ESSSSSSSSSSSSSS SSSSSSSSSSSSSSFOFOFOFOE E E E EEEEEEEEE E E E ///// /// ///// / / /// / //FOFOFOFOFOFOFOFOFO FOFOFO FOFOFOFO FOFOGGGGGGEEE GFO FOFOFOFOFOFO FO FO FO FOFOFOFOFOFOFOSS SS SS SS W W WWWWWWSD SD FO F O FO FO FO F O FOFOFOFOFOFOSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SS SS SS WWSD SD SD SD S D SDSSSSSSFOFOFO ESS SS SS COMCAST COMCAST COMCAST COMCAST COMCAST COMCAST COMCAST COMCAST COMCAST COMCAST COMCASTCOMCASTCOMC A S T COMC A S T COMC A S T COMC A S T COMCASTCOMCASTCOMCAS T C O M C A S T COMCAST COMCAST COMC A S T COMCASTCOMCAST FOCOMCAST CE N T U R Y L I N K F OCENTURYLINK FO CENTURYL I N K F O CENTUR Y L I N K F O CENTURYLIN K F O CENTU R Y L I N K F O CENTURYLINK FOCENT U R Y L I N K F OCENTURYLINK FOCENTURYLINK FOCENTU R Y L I N K F O CE N T U R Y L I N K F O CENTURYLINK FOCENTU R Y L I N K F O C E N T U R Y L I N K FO PSE PSE PSE PSE PSE 2-PSE 2-PSE 3-PSE PS E 2-PSE 3 - P SE 2-PSE 2- P S E PSE PSE PSE PSE PSE PSE PSE PSE PSEPSEPSE P S E PSE PSE PSEPSERENTO N RENTON RENTO N RENTONRENTON RENTON RENTON RENTON RENT O N RENT O N RE N T O N RE N T O N REN T O N RENTONRENT O N RENTO N RENTONRENT O N RENTO N RENTON RENTON RENTON RENTON WSDO T F O WSDOT FOWSDOT FO2- Z A Y O F O 2- Z A Y O F O PSE GAS PSE G A S PSE GAS PSE GAS PSE GAS PSE GASPSE GAS PSE GAS PSE GASPSE GAS PSE GAS PSE GASPSE GAS PSE G A S PO T HO L E SR TC - 1 9 BGND= 2 6 . 8 6 1 " P V C PWR TO P O F CND = 2 5 . 1 1 P O THO L E SR TC - 1 9AGN D = 2 6 . 8 6 6 " D I W TO P O F P IP E = 2 3 . 6 6 PO T HO L E SR TC - 2 6GND= 2 6 . 6 0 2 x 1 " P VC PWR TO P O F CND = 2 4 . 6 7 PO T HO L E SR TC - 1 2GND = 2 7 . 5 3 9 D IRE C T B U R I ED PWR CND TO P C EN T E R O F C AB LE S = 2 5 . 7 6 PO THO L E SR TC - 1 6GN D = 2 7 . 0 0 2 " P VC C OMM T O P O F P IP E = 2 4 . 3 8POTHO LE S R T C - 1 5 GND = 2 7 . 3 3 2 " S TW G A S TOP O F P I P E = 2 4 . 1 2 EEEEPO T H O L E S R T C - 2 1GND= 2 6 . 5 1 8 " D I W TOP O F P I PE = 2 3 . 7 0POTHO LE S R T C - 2 4GN D = 2 7 . 5 9 2 " S TW G A S TO P O F P I P E = 2 5 . 6 0 PO T H O L E SR TC - 2 5GND= 2 7 . 7 7 2 -P VC C N D PWR TO P O F CND = 2 6 . 8 4 TTT T GGGGGGGG GG PO THO L E S R T C - 2 0GN D = 2 5 . 3 7 8 " S T EE L W TO P O F P I P E = 2 2 . 4 9 PO T HO L E SR TC - 2 6 AGND = 2 7 . 4 2 2 " S TW G A S TO P O F P IP E = 2 5 . 2 0 PO THO L E SR T C - 1 1GN D = 2 8 . 0 0 0 . 5 " C A B L E C OMM TO P O F C N D = 2 5 . 4 5 EEE E E E EEEEWWWWWGGGE E EEE E E EEEEW WWWEEEU T I L V L T HHHHH HEE E E U N K N O W N U T I L I T Y C C C C C FO FO FO FO FO FO FO FO FO FO T T T T T TEFOFOETT TEEG G FOFOFO CCEFO PO T HO L E 3 9GND E L = 2 7 . 2 8 2 - 6 " PW R CNDPOTHO LE 3 8GN D E L = 2 7 . 4 6 1 " COMM D I R EC T BUR IE D C A B L E TO P O F C AB LE E L = 2 4 . 3 8POTHO LE 1 3 GND E L = 2 9 . 0 5 2 " POWE R CND TOP O F C N D E L = 2 6 . 8 4 POTHO LE 1 4GN D E L = 2 5 . 9 6 2 " POW E R CN D TO P O F C N D E L = 2 3 . 9 6 PO T HO L E 4 5GND E L = 2 4 . 0 6 2 " POW ER TO P O F CND E L = 2 2 . 2 8 PO T HO L E 4 8GND E L = 2 4 . 3 9 6 " S TORM P I P E TO P O F P IP E E L = 2 2 . 1 3 PO T HO L E 4 8 BGND E L = 2 4 . 3 8 4 " COMM CND TO P O F CND E L = 2 1 . 6 7 POTHO LE 4 9 GN D E L = 2 4 . 5 2 2 x 2 " POW ER TO P O F C N D E L = 2 2 . 6 3 PO T HO L E 5 3GND E L = 2 7 . 0 4 6 " GA S TO P O F P I P E E L = 2 2 . 4 1 P O THO L E 5 2GN D E L = 2 6 . 8 0DUG 6 ' D I D NO T F I N D P O THO L E 5 0GN D E L = 2 6 . 7 9 6 " & 4 " & 2 - 2 "& 1 " POWE R CND TO P O F CND E L = 2 5 . 3 1 HHGV GI R R G PO T HO L E 0 1GND E L = 2 9 . 0 5 4 " F IB ER O P T I C TO P O F CND E L = 2 7 . 0 1 PO T HO L E 1 4 AGND E L = 2 5 . 9 6 4 " COMM C N D TO P O F CND E L = 2 4 . 1 3 PO THO L E 5 1GN D E L = 2 7 . 0 4 4 x 4 " F I BE R O P T IC TO P O F CND E L = 2 2 . 6 6 E P O THO L E 4 9 AGN D E L = 2 4 . 5 2 2 x 4 " C OMM T O P O F C N D E L = 2 2 . 6 0 PO T HO L E 4 8 AGND E L = 2 4 . 3 8 2 " POW ER CND TO P O F CND E L = 2 1 . 9 6 PO THO L E 4 6GN D E L = 2 4 . 0 6 4 " F I B E R OP T IC TO P O F CND E L = 2 2 . 1 2 BOR E H O L ESB - 1EL = 2 7 . 1 7 BOREHO L E G A - 1 4 E L = 2 6 . 3 6 BOREHO L E P - 1 4 E L = 2 5 . 4 3 BO R EHO LE P - 1 2 E L = 2 5 . 1 4 BOREHO L E G A - 1EL = 2 5 . 0 9 BO R EHO L EGA- 2 E L = 2 5 . 9 8 MWE L = 2 5 . 0 8 B OR E H O L ERW1 0 E L = 2 5 . 3 0 MWGWMW- 2 E L = 2 6 . 0 6 BOR E H O L EGA - 3EL = 2 5 . 9 7MWGWMW- 1 E L = 2 6 . 6 0 BOREHO L E S B - 2 E L = 2 7 . 2 9 BOR E H O L EGA 1 2EL = 2 6 . 4 5 BORE HO L EGA - 1 3EL = 2 6 . 0 6 BORE HO L EP- 1 5EL = 2 5 . 6 6 PO T HO L E 5 1 AGND E L = 2 7 . 0 4 1 x 2 " & 2 x 6 " POW ER CND TO P O F CND E L = 2 4 . 6 6 ////////////////////////////////////////////////////////////////////////// / // / // / // / // / // / // /////////////////////////////////////////////////////////////////////////////////////// / // / // / // / // / // / // / // / // //////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// / // / // / // / // / // / / / / // / // / // / // / // / // / // / // / // /////////////////////////////////////////////////////////////////////////////////////// / // / / / / / / / / / / / / / / / / // / // / // / // / // / // / // / /// // / /// // / /// /// // / // / / / / / / / / / / ////////////// / ////////////////////////////////////////////////////// /// /// /// /// /////////////////////////////////////////// / // / / / / // // // / /////////////////////////////////////////////////////////////// // // // // // // // // // // // // // // ///// /// /// /// // / /// /// /// /// // / /// /// /// /// // / /// /// /// /// // / /// /// /// /// // / /// /// /// /// // / /// // / /// /// /// /// // / /// /// /// /// // / /// /// /// /// // / /// /// /// /// // / /// /// /// /// // / /// /// /// /// // / /// //////// // // //WWWWWWWW////////////////// /// /// /// /// /// /// /// /// /// // / /// /// /// /// /// /// // / /// // / /// /// /// /// /// /// // / /// /// /// /// /// /// // / /// /// /// /// /// /// // / /////////////////////SS SS SSSSSS WWW//////////////////// //////////////////////////// ////////////////////////// / // / // / // / // / // / // / // / // / // /// / / // // /// //// /// // //////////////////////////////////////////////////// /// ///////////////////////////////////////////////////////////////// // // // // // // // // // // // // // // // // ///////////////// // // ////// // // // // // // // // ////////////////// //////////////////////WWS S S S REMOVE EXISTING LIGHT FIXTURE, POLE, FOUNDATION, AND ASSOCIATED HANDHOLE 4 0 5 -C -R a i n i e r S 405-C- H a r di e S W 4 0 5 - C -G r a d yW RAINIER A V E S HARDI E A V E S W ADJUST EXISTING GAS VALVE ADJUST EXISTING GAS VALVE CONTRACT UNIT DESCRIPTION 5 UTILITES COMPOSITE UTILITY PLANS RAINIER AVE S 405-UCP502 30 ---- 1" = 40' No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/09/22 | 12:26 PM | DAVID.HARRISC:\BMS\WSP-PB-US-PW-02\DAVID.HARRIS@PERTEET.COM\D0342984\BRT-405-UCP500.DWGBRT-405-UCP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 N SCALE IN FEET 0 4020 8040 (1" = 40') S GR AD Y W A Y NOTES: UTILITY QUALITY LEVEL A: PRECISE HORIZONTAL AND VERTICAL LOCATION OF UTILITIES OBTAINED BY THE ACTUAL EXPOSURE (OR VERIFICATION OF PREVIOUSLY EXPOSED AND SURVEYED UTILITIES) AND SUBSEQUENT MEASUREMENT OF SUBSURFACE UTILITIES, USUALLY AT A SPECIFIC POINT. MINIMALLY INTRUSIVE EXCAVATION EQUIPMENT IS TYPICALLY USED TO MINIMIZE THE POTENTIAL FOR UTILITY DAMAGE. A PRECISE HORIZONTAL AND VERTICAL LOCATION, AS WELL AS OTHER UTILITY ATTRIBUTES, IS SHOWN ON PLAN DOCUMENTS. ACCURACY IS TYPICALLY SET TO 15-MM VERTICAL AND TO APPLICABLE HORIZONTAL SURVEY AND MAPPING ACCURACY AS DEFINED OR EXPECTED BY THE PROJECT OWNER. UTILITY QUALITY LEVEL B: INFORMATION OBTAINED THROUGH THE APPLICATION OF APPROPRIATE SURFACE GEOPHYSICAL METHODS TO DETERMINE THE EXISTENCE AND APPROXIMATE HORIZONTAL POSITION OF SUBSURFACE UTILITIES. QUALITY LEVEL B DATA SHOULD BE REPRODUCIBLE BY SURFACE GEOPHYSICS AT ANY POINT OF THE DEPICTION. THIS INFORMATION IS SURVEYED TO APPLICABLE TOLERANCES DEFINED BY THE PROJECT AND REDUCED ONTO PLAN DOCUMENTS. UTILITY QUALITY LEVEL C: INFORMATION OBTAINED BY SURVEYING AND PLOTTING VISIBLE ABOVE-GROUND UTILITY FEATURES AND BY USING PROFESSIONAL JUDGEMENT IN CORRELATING THIS INFORMATION TO QUALITY LEVEL D INFORMATION. UTILITY QUALITY LEVEL D: INFORMATION DERIVED FROM EXISTING RECORDS OR ORAL RECOLLECTIONS. GENERAL NOTES: ALL EXISTING UTILITY INFORMATION DEPICTED AT QUALITY LEVEL B UNLESS OTHERWISE NOTED. UTILITIES IN BROWN COLOR DEPICTED AT QUALITY LEVEL D. PROPOSED UTILITIES: STORM PIPE, SEE DRAINAGE PLAN 405-CDP501, 405-CDP502, 405-CDP503 ELECTRICAL CONDUIT/WIRE, SEE STREET LIGHTING PLAN 405-ELP501, 405-ELP502 FOR PAVING INFORMATION, SEE PAVING PLAN 405-CPP501, 405-CPP502 H H H H H FOFOFOFO405-C-G r a d y W 40 5 - C - H a r d i e S W 405-C-Grady-Drwy 405-C-CenterIslandN END BEGIN 405 - C - R a i n i e r - L a k e - D r w y16+0018+0075 0 + 0 0 75 0 + 0 0 152+00 154+00 156+00 158+00 160+00 161+00 11+47 10+00 19+ 2 6 10+00 12+ 0 0 14+0 0 16+00 18+ 0 0 17+65 10+00 12+0 0 14+00 16+00 9+ 5 1 10+ 0 0 12+ 0 0 14+00 16+00 18+00 18+30 14+70 9+75 10+0012+0014+00 S GRAD Y W A Y LAKE AVE SRAINIER AVE S5 5 5 5 5 7 7 7 5 7 7 7 1 2 7 13 13 405-C-CenterIslandN STA 10+26.72, 6.00' LT8 405-C-CenterIslandN STA 12+58.51, 6.00' LT8 405-C-CenterIslandN STA 15+84.60, 6.00' LT8 405-C-Rainier-Lake-Drwy STA 10+43.92, 0.00' END 2 405-C-Rainier-Lake-Drwy STA 13+15.42, 0.00' BEGIN2 405-C-Rainier-Lake-Drwy STA 18+66.72, 0.04' RT END2 405-C-Grady-Drwy STA 10+08.30, 0.08' RT BEGIN2 405-C-Grady-Drwy STA 11+30.02, 0.00' RT END 2 405-C-CenterIslandS STA 10+25.02, 0.07' RT BEGIN 4 405-C-CenterIslandS STA 10+39.92, 3.65' RT10 405-C-CenterIslandS STA 10+45.02, 4.36' LT11 405-C-CenterIslandS STA 13+36.10, 2.22' RT END 4 405-C-CenterIslandS STA 11+31.07, 6.00' LT8 405-C-CenterIslandS STA 11+31.07, 6.00' RT8 405-C-CenterIslandS STA 12+95.94, 6.00' LT8 405-C-CenterIslandS STA 12+95.94, 6.00' RT8 405-C-CenterIslandS STA 16+48.81, 0.48' RT8 405-C-CenterIslandS STA 12+45.54, 5.50' RT9 405-C-CenterIslandS STA 12+44.70, 9.42' LT9 405-C-CenterIslandS STA 11+87.00, 0.01' LT BEGIN 4 405-C-CenterIslandS STA 11+71.00, 0.01' LT END 4 405-C-CenterIslandS STA 17+78.05, 20.57' LT6 405-C-CenterIslandS STA 17+20.02, 32.16' RT6 405-C-CenterIslandN STA 10+23.22, 6.00' RT8 405-C-CenterIslandN STA 12+58.51, 6.00' RT8 405-C-CenterIslandS STA 17+94.46, 6.00' RT8 405-C-CenterIslandS STA 17+94.46, 6.00' LT8 405-C-CenterIslandN STA 15+84.60, 6.00' RT8 405-C-Rainier-Lake-Drwy STA 10+18.49, 0.00' BEGIN 2 PROPERTY LINE, TYP EXISTING ROW, TYP 405-C-LakeAve-S STA 10+17.49, 0.11' LT BEGIN 1 405-C-LakeAve-S STA 11+05.64, 1.17' LT 405-C-LakeAve-S STA 12+63.11, 0.00' END 2 405-C-LakeAve-S STA 12+79.11, 0.00' BEGIN 2 405-C-LakeAve-S STA 13+92.05, 0.00' END 2 405-C-LakeAve-S STA 14+70.00, 0.00' END2 405-C-LakeAve-S STA 14+08.15, 0.00' BEGIN2 PARKING GARAGE POTENTIAL FUTURE TOD AREA N SCALE IN FEET 0 4020 8040 (1" = 40') CONTRACT UNIT DESCRIPTION 5 CIVIL PAVEMENT MARKING PLAN SOUTH RENTON TC 405-CMP501 28 ---- 1" = 40' HARDIE AVE SWNo.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/02/22 | 2:50 PM | NELSONEC:\BMS\WSP-PB-US-PW-02\WSP__ERIC.NELSON\D0342984\BRT-405-CMP500.DWGBRT-405-CMP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/3/2022PRELIMINARY 405 R. GORMAN 02/3/2022RAINIER AVE SCONSTRUCTION NOTES: GENERAL NOTES: 1.CONTRACTOR SHALL REMOVE ALL CONFLICTING PAVEMENT MARKINGS. 2.SEE CITY OF RENTON STANDARD PLAN 109 FOR PAVEMENT MARKING MATERIAL TYPES. 3.RED-COLORED PAVEMENT MARKING MATERIAL SHALL BE WSDOT TYPE D METHYL METHACRYLATE. 4" YELLOW DOUBLE CENTERLINE (WSDOT STANDARD PLAN M-20.10) 8" WHITE WIDE LANE LINE (WSDOT STANDARD PLAN M-20.10) 1 BUS ONLY LEGEND LOW SPEED APPLICATION (WSDOT STANDARD PLAN M-80.10) TYPE 1 YIELD LINE (WSDOT STANDARD PLAN M-24.60) 4" YELLOW CENTERLINE (WSDOT STANDARD PLAN M-20.10) 16" WHITE STOPBAR (CITY OF RENTON STANDARD PLAN 128) 10' WIDE CROSSWALK (CITY OF RENTON STANDARD PLAN 127) TYPE 1S TRAFFIC ARROW (WSDOT STANDARD PLAN M-24.40) TYPE 2SL TRAFFIC ARROW (WSDOT STANDARD PLAN M-24.40) TYPE 3SR TRAFFIC ARROW (WSDOT STANDARD PLAN M-24.40) 2 4 5 6 7 8 9 10 11 RED-COLORED PAVEMENT MARKING13 3102/11/2022 X X // / / / //////////////// ///// / / ////////// ////// / / /////// / UT HHHHH/////////// T T E FO F O FO E EE E E E E E E E E EE EE /// / / / / / / / ///// / / //////////////// / / / / / ////////// / / / / //// / / //////// / / / / /// / / ////////XXX XXXXX X X XXXXXXX XXXXXX/////// /XXX////////////////// / / / / / / / / / / / / / / ///////// / //////// / / / / / /// / /// / / / / / / //////////////// / / / / / / ////// ///////// ///// / / / / / / / / / / /////// / / / / / // / / / ////// / // ///////// / / / /// / / /SSSSC C C C CCC405-C -R a i n i e r S 405-C- H ar di e S W 4 0 5 -C -G r a d yW 405-C -SW7THST 10+09 12+0 0 14+00 16+00 18+00 20+00 22+00 747+ 0 0 748+ 0 0 750+00750+00150+00 1 5 2 + 0 0 248+0010+00 12+0010+00 12+009+5110+0012+00PROPERTY LINE, TYP PROPERTY LINE, TYP 7 7 5 5 5 RAINIER A V E S SW 7TH ST HARDI E A V E S W 13 405-C-HardieSW STA 749+35.65, 0.00' END1 405-C-HardieSW STA 749+19.45, 12.33' RT12 405-C-HardieSW STA 748+25.20, 0.00' BEGIN1 405-C-RainierS STA 17+81.46, 10.44' LT BEGIN 4 405-C-RainierS STA 18+02.14, 6.01' LT10 405-C-RainierS STA 18+62.09, 6.50' LT8 405-C-RainierS STA 19+24.86, 9.04' LT10 405-C-RainierS STA 19+90.00, 15.00' LT END 4 405-C-RainierS STA 19+84.08, 7.50' LT8 7 7 EXISTING ROW, TYP CONTRACT UNIT DESCRIPTION 5 CIVIL PAVEMENT MARKING PLANS RAINIER AVE S 405-CMP502 32 ---- 1" = 40' No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/01/22 | 9:00 AM | NELSONEC:\BMS\WSP-PB-US-PW-02\WSP__ERIC.NELSON\D0342984\BRT-405-CMP500.DWGBRT-405-CMP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 N SCALE IN FEET 0 4020 8040 (1" = 40') S GRA D Y WA Y CONSTRUCTION NOTES: 4" YELLOW DOUBLE CENTERLINE (WSDOT STANDARD PLAN M-20.40) 8" WHITE WIDE LANE LINE (WSDOT STANDARD PLAN M-20.10) 1 BUS ONLY LEGEND LOW SPEED APPLICATION (WSDOT STANDARD PLAN M-80.10) GENERAL NOTES: 1.CONTRACTOR SHALL REMOVE ALL CONFLICTING PAVEMENT MARKINGS. 2.SEE CITY OF RENTON STANDARD PLAN 109 FOR PAVEMENT MARKING MATERIAL TYPES. PAVEMENT LETTERS AND RED PAVEMENT BACKGROUNDS SHALL BE FLAT MMA. 3.RED-COLORED PAVEMENT MARKING MATERIAL SHALL BE WSDOT TYPE D METHYL METHACRYLATE. 16" WHITE STOPBAR (CITY OF RENTON STANDARD PLAN 128) 10' WIDE CROSSWALK (CITY OF RENTON STANDARD PLAN 127) TYPE 2SR TRAFFIC ARROW (WSDOT STANDARD PLAN M-24.40) TYPE 2SR TRAFFIC ARROW (WSDOT STANDARD PLAN M-24.40) 4 5 7 8 10 12 RED-COLORED PAVEMENT MARKING13 UTH H H H SD SD SSSS SDSDSDSDSDSDSDSDSD EECOEEEE EE E E E E W W W EEEEEWWWWWWWWWWWWW WW W W W W W G G G G G EEEEEG G G EEEEEEGGGGGEEEEEW WEEEEEEEEEE E EEEE EE T T T T T TT TG G EEEEEEEEEEEE E EEEEEEEEEEEEEEEGGGGGGGGGGG GGG FOFOFOFOFOFOFOFOFOFOFOFOFOFOFO FOFOFOFOFO FO FO FOWWWWWWWWWWWWWWWWWW SDSDFOFOFOFO FOFOFO FOFO FOFO FOFOFOFOFOFOFOFOFOFOFOFOFOWW W W SDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDE EEEEEEEEEEEEEEEEEEFOFOFO FOFO FOXXX X X X X X X X X X //////////////////////////////////////////////////////// SD SDSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSFO EEE E E E E E E E E E E E E E E E ///////////////////////////FOFOFOFOFOFOESSSSSSSSSSWSDSDSSSSSDSDSDSDEGG E E E E W W W W W G G G G G EEEEWWW ETCCCCCCCCCCC TTTTTTTTTTTTTEEEET T T T T TEEEEEGGGGCCC C C C GGG EEEEEBOREHOLE P-14 EL=25.43 BOREHOLE P-12 EL=25.14 BOREHOLE GA-1 EL=25.09 BOREHOLE GA-2 EL=25.98 RAINIER AVE S16+0018+00748+0075 0 + 0 0 75 0 + 0 0 10+00 9+ 5 1 10+ 0 0HARDIE AVE SW40 5 - C - H a r d i e S W 11 22 21 61 34 22 23 EVPC 405-C-RainierS1 4 4 5 4 7 6 8 4 11 4 10 3 62 63 EVPA 41 42 33 89 87 86 68 69 28 32 31 43 EVP D 28 CCEXISTING ROW, TYP 6 5 2 7 1 4 3 1 5 88 6 5 12 5 95 8 9 PROPERTY LINE, TYP N 20 40 SCALE IN FEET 01020 (1" = 20') CONTRACT UNIT DESCRIPTION 5 TRAFFIC SIGNAL PLANS RAINIER AVE S & HARDIE AVE SW 405-TSP502 33 ---- 1" = 20' No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/07/22 | 8:57 AM | NELSONEC:\BMS\WSP-PB-US-PW-02\WSP__ERIC.NELSON\D0389173\BRT-405-TSP500.DWGBRT-405-TSP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 CONSTRUCTION NOTES CONSTRUCT COMBINED CABINET FOUNDATION PER CITY OF RENTON STANDARD PLAN 126.2. FURNISH AND INSTALL TYPE P CONTROLLER CABINET AND ELECTRICAL SERVICE CABINET. CONSTRUCT SIGNAL STANDARD FOUNDATION PER WSDOT STANDARD PLAN J-26.10 AND INSTALL TYPE SD SIGNAL STANDARD WITH DUAL MAST ARMS. INSTALL FOUR VEHICLE SIGNAL HEADS, ONE VIDEO DETECTION CAMERA, AND ONE EMERGENCY PREEMPTION DETECTOR ON ONE MAST ARM AND INSTALL THREE VEHICLE SIGNAL HEADS AND ONE VIDEO DETECTION CAMERA ON THE OTHER. INSTALL ONE PEDESTRIAN SIGNAL HEAD, ONE APS PUSHBUTTON ASSEMBLY, AND ONE TERMINAL CABINET ON POLE. CONSTRUCT SIGNAL STANDARD FOUNDATION PER WSDOT STANDARD PLAN J-26.10 AND INSTALL TYPE III SIGNAL STANDARD. INSTALL THREE VEHICLE SIGNAL HEADS, ONE VIDEO DETECTION CAMERA, AND ONE EMERGENCY PREEMPTION DETECTOR ON MAST ARM. INSTALL ONE PEDESTRIAN SIGNAL HEAD, ONE APS PUSHBUTTON ASSEMBLY, AND ONE TERMINAL CABINET ON POLE. CONSTRUCT FIXED BASE FOUNDATION PER WSDOT STANDARD PLAN J-21.10 AND INSTALL TYPE PS SIGNAL STANDARD. INSTALL ONE PEDESTRIAN SIGNAL HEAD AND ONE APS PUSHBUTTON ASSEMBLY ON POLE. CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-20.10 AND INSTALL ACCESSIBLE PEDESTRIAN PUSHBUTTON POST. INSTALL ONE APS PUSHBUTTON ASSEMBLY ON POST. CONSTRUCT SIGNAL STANDARD FOUNDATION PER WSDOT STANDARD PLAN J-26.10 AND INSTALL TYPE II SIGNAL STANDARD. INSTALL THREE VEHICLE SIGNAL HEADS, ONE VIDEO DETECTION CAMERA, AND ONE EMERGENCY PREEMPTION DETECTOR ON MAST ARM. INSTALL ONE PEDESTRIAN SIGNAL HEAD, ONE APS PUSHBUTTON ASSEMBLY, AND ONE TERMINAL CABINET ON POLE. 2 3 1 4 C 2A EVP PHASES 6+1 PRE-EMPTION SCHEDULE D 3 SIGNAL HEAD DISPLAYS VEHICLE SIGNAL HEADS NO. 22, 23, 31, 32, 33, 41, 42, 43, 61, 62, 63 R Y G 12" 12" 12" PEDESTRIAN SIGNAL HEADS NO. 28, 29, 68, 69, 86, 87, 88, 89 PHASE DIAGRAM Ø8 PROTECTED VEHICLE MOVEMENT PROTECTED PEDESTRIAN MOVEMENT Ø4 Ø7 Ø3 Ø6 Ø2 Ø5 Ø1 GENERAL NOTES: 1.SEE TSP PLANS FOR ADDITIONAL SIGNAL WORK AT THIS INTERSECTION. 2.SEE ELECTRICAL PLAN FOR LUMINAIRE INSTALLATION AT THIS INTERSECTION. NOT USED NOT USED 5 SIGN DISPLAYS R5-1 SIGN NUMBER 1 36" X 36" R3-2 (MOD) SIGN NUMBER 2 30" X 42" STREET NAME SIGN SIGN NUMBER 4, 5 126" X 18" R3-1 (MOD) SIGN NUMBER 3 30" X 42" STREET NAME SIGN SIGN NUMBER 6, 7 120" X 18" * LEAD PEDESTRIAN INTERVAL * 6 R3-5R (MOD) SIGN NUMBER 9 30" X 48" R3-2 SIGN NUMBER 8 30" X 30"VEHICLE SIGNAL HEAD NO. 21 R Y G 12" 12" 12" NEW JUNCTION BOX TYPE 1 NEW JUNCTION BOX TYPE 2 NEW JUNCTION BOX TYPE 8 NEW CONDUIT NEW EMERGENCY VEHICLE PREEMPTION NEW VEHICLE SIGNAL HEAD NEW PEDESTRIAN SIGNAL HEAD POLE CALL OUT LEGEND 12" 12" 12" W FLW W BRT SIGNAL HEAD NO. 11 # PERMISSIVE VEHICLE MOVEMENT AeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinCONSTRUCTION NOTES: INSTALL GPS ANTENNA ON EXISTING SIGNAL MAST ARM.1 2 CONNECT GPS ANTENNA CABLE TO EXISTING OPTICOM 764 PHASE SELECTOR AND INSTALL ONE OPTICOM 768 AUXILIARY INTERFACE PANEL IN EXISTING TRAFFIC SIGNAL CONTROLLER CABINET. X X X X XASPHSSSSSSSS SSSSSSSSSSSD SS SS18" CONCCWSW SW 4' WOOD FNCC W SW CONC SEA M S ( T Y P ) C&G C&G C&G OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE SWEEW E E E E E E EW E E E E E E E EEEEEEWWWWWWWW E E E FOEEEEEE EE E E E E E WWWWEEE E E E E E EEE E E E E E E E E EE E E E E E E E EE EE E E E EEEEEE E E E E E E E E E E E EEEE EEE E E E E E GG FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO W W W W W WWWSD SD WW FOFOFOFO FOFOFOFO FO FO FO FO FO FO SD SDSDSDSDSDSDSD SD SD SDSDSDSDSDS D S DSDSD SD SDSDSD SD SD SD S S S S S S S S FOFOFOFOEEEEE E E E E E E E E E EEEEEEEEEEEEE EEEEEEEEE EE EE E E E E E EEE FO FO FO FOFOFO FOFOFO OE OE OE OE OE OE MISC VALVFOFOFO FOFO FOSSSSSD SD SD SS SS SS SSSSSSSSFOFOFOFOFOFOFOFOFOFOCOMCASTCOMCASTCOMCAST COMCAST CENT U R Y LI N K F O3-PSE2-PSE3-PSE 2-PSE 2-PSE PSE PSE PSERENTONRENT O N RENTO N REN T O N RENTONRENTON RENTONRENTONRENTONRENTONRENTONWSDOT FOWSDOT FO2-ZAYO FO 2-ZAYO FO T T T T T TEEEEEEEEE28 28 28 28 262610+09 150+00 152+00 1011+47AeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinLabel contains broken referenceLabel contains broken referenceLabel contains broken referenceLabel contains broken referenceEXISTING TRAFFIC SIGNAL CONTROLLER CABINET EXISTING JUNCTION BOX TYPE 8 EXISTING CONDUIT EXISTING TRAFFIC SIGNAL POLE EXISTING VEHICLE SIGNAL HEAD EXISTING EMERGENCY PREEMPTION DETECTOR EXISTING MAST ARM MOUNTED SIGN EXISTING VIDEO DETECTION CAMERA EXISTING GPS ANTENNA EXISTING KCM TSP WAP NEW GPS ANTENNA LEGEND: 20 40 SCALE IN FEET 01020 (1" = 20') TRAFFIC TSP PLAN RAINIER AVE S & S GRADY WAY IN RENTON 405-TIP501 34 0 1" = 20'RAINIER AVE SS GRADY W A Y N CONTRACT UNIT DESCRIPTION 5 1 WIRING SCHEDULE RUN NO.CONDUIT SIZE CONDUCTORS REMARKS EXISTING NEW 1 EX 3"2-5C, 1-VIDEO, 2-M138 1-GPS EX 2"2-#8, 3-#12 2 EX 4"5-5C, 6-2C, 1-VIDEO 1-GPS EX 4"4-5C, 6-2C, 1-VIDEO, 4-M138 X EX. TRAFFIC SIGNAL POLE EX. TYPE 8 JB 2 EX. TRAFFIC SIGNAL CONTROLLER CABINET 2 EXISTING PHASE DIAGRAM Ø8 PROTECTED VEHICLE MOVEMENT Ø4 Ø7 Ø3 Ø6 Ø2 Ø5 Ø1 PEDESTRIAN MOVEMENT (A) OVERLAP PHASE LETTER(X) TSP LOW PRIORITY SCHEDULE CHANNEL PHASE A Ø2 B Ø6 1 No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/09/22 | 1:30 PM | XXLC:\BMS\WSP-PB-US-PW-02\XIAOYI.LIU@CONCORDENGR.COM\D0389173\BRT-405-TIP500.DWGBRT-405-TIP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 EXISTING ROW, TYP GENERAL NOTES: 1.SEE SIGNAL PLAN FOR ADDITIONAL SIGNAL WORK AT THIS INTERSECTION. CONSTRUCTION NOTES: INSTALL GPS ANTENNA ON SIGNAL MAST ARM.1 CONNECT GPS ANTENNA CABLE TO OPTICOM 764 PHASE SELECTOR. OPTICOM 764 PHASE SELECTOR AND OPTICOM 768 AUXILIARY INTERFACE PANEL FURNISHED AS PART OF NEW TRAFFIC SIGNAL CABINET. 2 CONC SIGN SIGN E 1,298,000E 1,298,100E 1,298,200N 175,600 UTUT H H H H VLT VLT VLTS E 1,298,200N 175,600SW SD SSSS SDSDSDSDSDSDSDSDSD DRWDRWECOEEEGVGVGV E E E E E W W W EEEWWWWWWWWWW WW W W W G G G G G EEEE G G G FOFOFOFO EEEEEGGGG GEEEEFO F OFO EEEEEE E E T T T T G G EEEEEEEEE E EEEEEEEEEEEEEGGGGGGGGGG GGG FOFOFO FOFOFOFOFOFOFOFOFOFOFOFO FOFOFOFOFO WWWWWWWWWWWWWWSDSDFOFOFOFO FO FOFOFOFOFOFOFOFO FOFOFOFOFOWW W W SDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDEEEEEEEEEEEEEEEEEFOFOFO FOFO FOXXX X X X X X X X ////////////////SDSS SSSSSSSSSSSSSSSSSSSSSSSSE E E E E E E E E E E E E E ////////////////////////////////////////FOFOFOFOFOFOSSSSSSSSSSWSDSDSSSSSSSDSDSDSDCOMCASTCOMCASTCOMCAST COMCASTCOMCASTCO M C A S TCOMCAST COMCASTCOMCASTCOMCAST CO M C A S T F OCENTURYLINK FOCENTURYLINK FOPSEPSEPSEPSEPSEPSEPSEPSEPSE PSE PSE RENT O N RENTONRENTONRENTONRENTONRENT ON PSE GASPS E G A S PSE GAS PSE GASP S E G A S E E W W G G TCCCCCCCCCC FOFOFOFOFOFOFOFOFOFO FOFOFOFOFOFOFOFOFOFO TTTTTTTTTTTTEEFOFOFOFOFOEET T T EEEEEGGGGFOFOFOFOFOFOCC C C C C HH GV G GG EEEEE2626262616+0018+00P T = 1 8 + 9 0 . 1 6 BP = 10+00.00 PC = 10+42.88 N: 175469.62 E: 1298163.69 9+ 5 1 10+ 0 0BP = 9+51.35PI = 10+00.00AeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinLabel contains broken referenceLabel contains broken referenceLabel contains broken referenceLabel contains broken referenceNEW GPS ANTENNA LEGEND: 20 40 SCALE IN FEET 01020 (1" = 20') TRAFFIC TSP PLAN RAINIER AVE S & HARDIE AVE SW IN RENTON 405-TIP502 35 0 1" = 20' N H A R D I E A V E S W RAINIER AVE SCONTRACT UNIT DESCRIPTION 5 WIRING SCHEDULE RUN NO. CONDUIT SIZE CONDUCTORS REMARKS 1 SEE SIGNAL PLAN 1-GPS SEE SIGNAL PLAN FOR OTHER CONDUCTORS IN CONDUIT 2 SEE SIGNAL PLAN 1-GPS SEE SIGNAL PLAN FOR OTHER CONDUCTORS IN CONDUIT 3 SEE SIGNAL PLAN 1-GPS SEE SIGNAL PLAN FOR OTHER CONDUCTORS IN CONDUIT X PROPOSED PHASE DIAGRAM Ø8 PROTECTED VEHICLE MOVEMENT PROTECTED PEDESTRIAN MOVEMENT Ø4 Ø7 Ø3 Ø6 Ø2 Ø5 Ø1 TSP LOW PRIORITY SCHEDULE CHANNEL PHASE A Ø2 B Ø4 No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/09/22 | 1:32 PM | XXLC:\BMS\WSP-PB-US-PW-02\XIAOYI.LIU@CONCORDENGR.COM\D0389173\BRT-405-TIP500.DWGBRT-405-TIP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 EXISTING ROW, TYP 2 SEE SIGNAL PLAN FOR NEW MAST ARM POLE 1 SEE SIGNAL PLAN 405-TSP502 FOR NEW SIGNAL CABINET NOT USED NOT USED 1 SEE SIGNAL PLAN 405-TSP502 3 2 SEE SIGNAL PLAN 405-TSP502 H HE E E T X X X X X X X X FOFOFOFOCC BOREHOLE EL=25.43 BOREHOLE RW10 EL=25.30 BOREHOLE P-15 EL=25.66 S GRADY W A Y LAKE AVE SRAINIER AVE S16+0018+0075 0 + 0 0 75 0 + 0 0 152+00 154+00 156+00 158+00 160+00 161+00 11+46 10+00 19+ 2 6 10+00 12+ 0 0 14+0 0 16+00 18+ 0 0 17+65 10+00 12+0 0 14+00 16+00 9+ 5 1 10+ 0 0 12+ 0 0 14+00 16+00 18+00 18+30 14+70 9+75 10+0012+0014+00 405-C-G r a d y W 40 5 - C - H a r d i e S W 405-C-Grady-Drwy 405-C-Grady-Drwy STA 11+29.2, 14.9' RT INSTALL R1-1 SIGN 405 - C - R a i n i e r - L a k e - D r w y 405 - C - C e n t e r I s l a n d N 405-C-CenterIslandN STA 11+46.2, 17.8' RT INSTALL BUS STOP SIGN 405-C-CenterIslandN STA 13+27.7, 20.4' RT INSTALL BUS STOP SIGN 405-C-CenterIslandN STA 15+84.8, 17.2' RT INSTALL BUS STOP SIGN 405-C-CenterIslandN STA 17+62.9, 19.7' RT INSTALL R1-1 SIGN AND R5-1 SIGN 405-C-CenterIslandN STA 17+60.0, 18.5' LT INSTALL R5-1 SIGN 405-C-CenterIslandN STA 14+56.9, 17.3' RT INSTALL BUS STOP SIGN 405-C-Grady-Drwy STA 10+08.1, 18.6' LT INSTALL R1-1 SIGN 405-C-Rainier-Lake-Drwy STA 18+68.3, 14.6' RT INSTALL R1-1 SIGN 405-C-CenterIslandN STA 17+62.6, 47.1' RT INSTALL R5-1 (MOD) SIGN 405-C-CenterIslandN STA 17+62.6, 84.7' RT INSTALL R5-1 (MOD) SIGN 405-C-CenterIslandS STA 17+36.8, 25.8' RT INSTALL R1-2 SIGN 405-C-CenterIslandS STA 12+69.8, 19.0' LT INSTALL BUS STOP SIGN 405-C-CenterIslandS STA 13+92.9, 17.1' LT INSTALL BUS STOP SIGN 405-C-CenterIslandS STA 15+23.4, 17.0' LT INSTALL BUS STOP SIGN 405-C-CenterIslandS STA 16+71.6, 17.4' LT INSTALL BUS STOP SIGN 405-C-CenterIslandS STA 17+53.8, 21.8' LT INSTALL R1-2 SIGN PARKING GARAGE POTENTIAL FUTURE TOD AREA PROPERTY LINE, TYP PROPERTY LINE, TYP EXISTING ROW, TYP N SCALE IN FEET 0 4020 8040 (1" = 40')HARDIE AVE SWNo.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/01/22 | 3:25 PM | NELSONEC:\BMS\WSP-PB-US-PW-02\WSP__ERIC.NELSON\D0342984\BRT-405-TNP500.DWGBRT-405-TNP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022RAINIER AVE SGENERAL NOTES: 1.INSTALL SIGNS PER CITY OF RENTON STANDARD PLANS, SECTION G. 2.SEE WSDOT SIGN FABRICATION MANUAL AND MUTCD FOR STANDARD SIGN CODES. LEGEND EXISTING NEW SIGN OVERHEAD SIGN SIGN DETAIL R5-1 (MOD) 30" X 42" CONTRACT UNIT DESCRIPTION 5 TRAFFIC SIGNING PLANS SOUTH RENTON TRANSIT CENTER 405-TNP501 36 ---- 1" = 40' // / / / //////////////// ///// / / ////////// ////// / / /////// / UT HHHHH/////////// T T E FO F O FO E EE E E E E E E XXXXXXX/ // ///////// / /// / / /SSSC CCBOR E H O L E P - 1 4EL = 2 5 . 4 3 BOREHO L E P - 1 2 E L = 2 5 . 1 4 BO R EHO L E RW 1 0 E L = 2 5 . 3 0 BO R EHO LE P - 1 5 E L = 2 5 . 6 6 RAINIER A V E S 10+09 12+0 0 14+00 16+00 18+00 20+00 22+00 747+ 0 0 748+ 0 0 750+00750+00150+00 1 5 2 + 0 0 248+0010+00 12+0010+00 12+009+5110+0012+00SW 7TH ST PROPERTY LINE, TYP HARDI E A V E S W 4 0 5 -C -R a i n i e r S 405-C- H ar di e S W 4 0 5 -C -G r a d yW 405-C -SW7THST EXISTING ROW, TYP 405-C-Rainier-Lake-Drwy STA 10+15.3, 15.9' LT INSTALL R1-1 SIGN 405-C-CenterIslandN STA 10+15.8, 18.0' RT INSTALL R5-1 (MOD) SIGN 405-C-CenterIslandN STA 10+24.2, 17.4' LT INSTALL R5-1 (MOD) SIGN INSTALL R3-1 (MOD) SIGN ON MAST ARM INSTALL R5-1 SIGN AND R5-1A SIGN ON SIGNAL POLE INSTALL R3-5R (MOD) SIGN ON MAST ARM INSTALL STREET NAME SIGN ON MAST ARM INSTALL STREET NAME SIGN ON MAST ARM INSTALL STREET NAME SIGN ON MAST ARM INSTALL R3-2 (MOD) SIGN ON MAST ARM 405-C-Rainier-Lake-Drwy405-C-CenterIslandNINSTALL R5-1 SIGN ON MAST ARM 405-C-CenterIslandN STA 10+11.1, 38.9' RT INSTALL R5-1 (MOD) SIGN PARKINGGARAGEPOTENTIALFUTURETOD AREA INSTALL R3-2 SIGN ON MAST ARM CONTRACT UNIT DESCRIPTION 5 TRAFFIC SIGNING PLANS RAINIER AVE S 405-TNP502 37 ---- 1" = 40' No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/01/22 | 3:26 PM | NELSONEC:\BMS\WSP-PB-US-PW-02\WSP__ERIC.NELSON\D0342984\BRT-405-TNP500.DWGBRT-405-TNP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 N SCALE IN FEET 0 4020 8040 (1" = 40') S GRA D Y WA Y GENERAL NOTES: 1.INSTALL SIGNS PER CITY OF RENTON STANDARD PLANS, SECTION G. 2.SEE WSDOT SIGN FABRICATION MANUAL AND MUTCD FOR STANDARD SIGN CODES. LEGEND EXISTING NEW SIGN OVERHEAD SIGN R5-1 (MOD) 30" X 42" R3-5R (MOD) 30" X 48" SIGN DISPLAYS R3-2 (MOD) 30" X 42" R3-1 (MOD) 30" X 42" PLATFORM LEGENDCIRCULATION ZONESTRUCTURE ZONEAMENITY ZONEBOARDING ZONE PAVERS (6'X6')DETECTABLE WARNING TILEWINDSCREENSTRASH RECEPTACLEBENCHESLEANING RAILRIDER INFORMATIONAPPROXIMATE CIRCULATION CONNECTION LOCATIONS. TO BE CONFIRMED WITH FINAL CANOPY DESIGN.(STRIDE) BUS BAY 1BUS BAY 2BUS BAY 8 (STRIDE)BUS BAY 3BUS BAY 4BUS BAY 5BUS BAY 6BUS BAY 7SHELTER ROOF ABOVE29' - 0"35'4'10'9'POWER LINE EASEMENTSAFETY RAILING AND/OR BARRIER4'4'PARKING GARAGESTRUCTURE ZONECIRCULATION ZONESTRUCTURE ZONECIRCULATION ZONESTRUCTURE ZONECIRCULATION ZONEHARDSCAPE BUFFER - SEE HARDSCAPE DRAWINGS3'18'LANDSCAPE - SEE LANDSCAPE DRAWINGS2'4'4'4'YARD HYDRANTYARD HYDRANTYARD HYDRANTYARD HYDRANTYARD HYDRANT8' - 6"3'SHELTER ROOF ABOVE8' - 6"29' - 0"3' - 0"4' - 0"3'3' - 0"29'SEE UTILITY PLANS FOR CONNECTIONS TO YARD HYDRANTSLANDSCAPE - SEE LANDSCAPE DRAWINGSSAFETY RAILING AND/OR BARRIERAMENITY ZONE85'140'18'SAFETY RAILING AND/OR BARRIER AT PLATFORM EDGE WHERE BUS MAY OVERHANG PLATFORM UPON PULL-IN TO BAY18'18'DETECTABLE WARNING TILE, TYP.SAFETY RAILING AND/OR BARRIER AT PLATFORM EDGE WHERE BUS MAY OVERHANG PLATFORM UPON PULL-IN TO BAYBIKE LOCKERS - SEE 405-LHP50111'5'4'20' - 6"SAFETY RAILING AND/OR BARRIERSAFETY RAILING AND/OR BARRIERRAINIER AVE SAMENITY ZONEAMENITY ZONE9"6"9"6"6"6"6"6"SAFETY RAILING AND/OR BARRIER AT PLATFORM EDGE WHERE BUS MAY OVERHANG PLATFORM UPON PULL-IN TO BAYSAFETY RAILING AND/OR BARRIER+/- 75'ALLOWABLE ENCROACHMENT WITHIN POWER EASEMENT, PER SEATTLE CITY LIGHT 100' CLEARANCE AROUND POWER POLES.PRINTED ON:2021 PIVOT ARCHITECTUREFROM FILE:CI-405 BRTCONTRACT UNIT DESCRIPTION 5No.DATEDSN CHKAPPREVISIONDESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SUBMITTED BY:DATE:REVIEWED BY: DATE: DATE:CONTRACT ID:FILENAME:SCALE:DRAWING No.:SHEET No.:REV:LINE IS 1" ATFULL SCALELOCATION No.:-1-AS NOTEDPHASE 3 - 30% SUBMITTALPRELIMINARY AE 0054-17ARCHITECTURESTATION PLATFORM PLANR. GORMAN4052/3/2022 9:24:59 AMC:\Pivot_Architecture\Revit_2020\1813_RentonTC_TOD_R20_bwardle.rvt3802/11/22SOUTH RENTON TRANSIT CENTER02/11/220'GRAPHIC SCALE30'60'15'BRT-405-ASP500405-ASP501N1" = 30'-0"1SOUTH RENTON TC STATION PLATFORM PLAN2SAFETY RAILING AND/OR BARRIER EXAMPLE SDSDSDSDSDSDSDSDSDSDSD SDS D SD SD SD SD 111213H H X X X X X X X X E E E E BORE H O L E RW10 EL=25 . 3 0 9.5'7.0' 3.5', TYP EXISTING ROW, TYP RAINIER AVE SVARIES, SEE ARC 24.0', TYPTYP 8 3 6 8 3 2 88 1 2 61.0' 63.0' (TYP OF 7) 5 8 (TYP OF 4) 7 (TYP OF 8) 4 50.0'4.5'5.0', TYPPROPERTY LINE, TYP TYP PARKING GARAGE 109 11 SEE ARCHITECTURE STATION PLAN 10.5'X X 71.5' 37.5'11.0 ' (TYP OF 6) 4 SEE ARCHITECTURE STATION PLAN N 20 40 SCALE IN FEET 01020 (1" = 20') CONTRACT UNIT DESCRIPTION 5 LANDSCAPING HARDSCAPE PLANS SOUTH RENTON TRANSIT CENTER & RAINIER AVE S 405-LHP501 39 0 1" = 20' No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/07/22 | 10:03 AM | USDW675573C:\BMS\WSP-PB-US-PW-02\DAN.WOJTALA@WSP.COM\D0342984\BRT-405-LHP500.DWGBRT-405-LHP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 GENERAL NOTES: 1.SEE SHEET 405-CXP501 FOR DEMOLITION AND REMOVAL PLAN. 2.SEE SHEET 405-CDP501 FOR DRAINAGE PLAN. 3.SEE SHEET 405-CPP501 FOR PAVING PLAN. 4.SEE SHEETS 405-CMP501 AND 405-TNP501 FOR PAVEMENT MARKING AND SIGNAGE PLANS. 5.SEE SHEETS 405-ELP501 FOR LIGHTING PLANS. 6.SEE SHEET 405-LPP501 FOR PLANTING PLAN. 7.SEE SHEET 405-LRP501 FOR IRRIGATION PLAN. 8.SEE SHEET 405-UCP501 FOR UTILITY PLAN. CONSTRUCTION NOTES: 1 3 CEMENT CONCRETE PAVEMENT WITH STAMPED PATTERN 4 2 6 7 5 INSTALL CEMENT CONCRETE PAVEMENT WITH INTEGRAL COLOR IN ALIGNMENT WITH GARAGE VERTICAL COLUMNS WHEN ABUTTING INSTALL QUAD ELOCKERS PER BIKELINK G5 ELOCKER TECHNICAL FEATURES AND SPECIFICATIONS INSTALL BIKE RACKS PER SPORTWORKS TOFINO NO SCRATCH BIKE RACK TECHNICAL DRAWINGS INSTALL MIXED BLEND OF 5 - 10" SIZE CLEAN WASHED RIVER COBBLES TO 50% DEPTH IN CEMENT CONCRETE PAVEMENT INSTALL BENCHES PER FORMS AND SURFACES RS PUBLIC SEATING TECHNICAL DRAWINGS AND IN ACCORDANCE WITH THE SOUND TRANSIT DESIGN CRITERIA MANUAL INSTALL PEDESTAL MOUNT PERFORATED PICNIC TABLE PER WABASH VALLEY, INC. TECHNICAL DRAWINGS INSTALL TREE GRATES IN ACCORDANCE WITH THE SOUND TRANSIT DESIGN CRITERIA MANUAL 8 INSTALL LARGE PERFORATED WASTE/RECYCLING RECEPTACLES IN ACCORDANCE WITH THE SOUND TRANSIT DESIGN CRITERIA MANUAL BICYCLE LOCKERS AT BUS BAYS 4/5 LEGEND 9 INSTALL CEMENT CONCRETE PAVEMENT WITH INTEGRAL COLOR IN STAMPED HERRINGBONE PATTERN 10 STAMPED PATTERN TO BE SET FLUSH WITH CURB ROUNDED RIVER COBBLE INTEGRAL COLORED CONCRETE PAVEMENT/PATTERN BENCH QUAD ELOCKER BICYCLE RACK PICNIC TABLE TREE GRATE WASTE/RECYCLING RECEPTACLE 11 SAFETY RAILING AND/OR BARRIER TYPE TO BE DETERMINED SDSD SD SD SDSDSD SD SD SDSDSDSDSDSDSD SD SD SDUTH H H H H ECOEEEE W EE E TSSSSSSSSSSSSSSSSSSSSSSSSSSSSEE FO FO FO FO FOFO FOEFOFOFOFOFOFOFOWWWWSSFO FO SSSSSSSSSSSSSSSSSSSSC C BOREHOLE P-14 EL=25.43 P-12 EL=25.14 BOREHOLE RW10 EL=25.30 BOREHOLE P-15 EL=25.66HARDIEAVE SWS GRADY W A YRAINIER AVE SPROPERTY LINE, TYP EXISTING ROW, TYP 5 CHARGER CHARGER CHARGER CHARGER CHARGER CHARGER CHARGER TRANSFORMER CHARGER SWITCHGEAR CHARGER CHARGER CHARGER IT CHARGER 12345678910111213EXISTING ROW, TYP 1 1 2 3 2 3 2 3 2 3 2 3 2 3 2 3 32 2 3 8 (TYP OF 4) 4 LAKE AVE S1 6 6 6 7 2 3 23 PARKING GARAGE 9 9 9 POTENTIAL FUTURE TOD AREA 9 N SCALE IN FEET 0 4020 8040 (1" = 40') CONTRACT UNIT DESCRIPTION 5 LANDSCAPING PLANTING PLANS SOUTH RENTON TRANSIT CENTER & RAINIER AVE S 405-LPP501 40 0 1" = 40' No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/07/22 | 10:49 AM | USDW675573C:\BMS\WSP-PB-US-PW-02\DAN.WOJTALA@WSP.COM\D0342984\BRT-405-LPP500.DWGBRT-405-LPP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 GENERAL NOTES: 1.SEE SHEET 405-CXP501 FOR DEMOLITION AND REMOVAL PLAN. 2.SEE SHEET 405-CDP501 FOR DRAINAGE PLAN. 3.SEE SHEET 405-CPP501 FOR PAVING PLAN. 4.SEE SHEETS 405-CMP501 AND 405-TNP501 FOR PAVEMENT MARKING AND SIGNAGE PLANS. 5.SEE SHEETS 405-ELP501 FOR LIGHTING PLANS. 6.SEE SHEET 405-LHP501 FOR HARDSCAPE PLAN. 7.SEE SHEET 405-LRP501 FOR IRRIGATION PLAN. 8.SEE SHEET 405-UCP501 FOR UTILITY PLAN. CONSTRUCTION NOTES: 1 INSTALL GRASS LAWN AND TOPSOIL PER THE SOUND TRANSIT DESIGN CRITERIA MANUAL GRASS LAWN REINFORCED GRASS LAWN LOW GROWING SHRUBS BIORETENTION PLANTINGS DECIDUOUS/ACCENT TREES CONIFER TREES WETLAND PLANTINGS LEGEND 3 INSTALL TOPSOIL AND MULCH TO THE DEPTHS REQUIRED PER THE SOUND TRANSIT DESIGN CRITERIA MANUAL FOR PLANTING AREAS 2 INSTALL PLANT MATERIAL PER CHAPTER 4-4-070 OF THE CITY OF RENTON MUNICIPAL CODE AND PER THE HEIGHT RESTRICTION REQUIREMENTS OF THE SOUND TRANSIT DESIGN CRITERIA MANUAL FOR PEDESTRIAN ZONES 4 INSTALL PLANT MATERIAL, TOPSOIL, AND MULCH IN BIORETENTION AREAS PER THE WASHINGTON STATE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR WESTERN WASHINGTON 5 6 INSTALL TREE IN FILTERRA UNIT INSTALL REINFORCED GRASS UNITS TO MEET TRUCK LOADING REQUIREMENTS FOR UTILITY ACCESS 7 INSTALL WETLAND PLANTS IN MODULAR WETLAND UNIT 8 INSTALL TREE IN TREE GRATE 9 INSTALL 6' TALL ORNAMENTAL FENCE PER AMERISTAR MONTAGE COMMERCIAL WITH 4' MAN GATE AT CHARGING STATION 12345678910111213UTH H H H H ECOEEEE W EE E TSSSSSSSSSSSSSSSSSSSSSSSSSSSSEE FO FO FO FO FOFO FOEFOFOFOFOFOFOFOWWWWSSFO FO SSSSSSSSSSSSSSSSSSSSC C BOREHOLE P-14 EL=25.43 P-12 EL=25.14 BOREHOLE RW10 EL=25.30 BOREHOLE P-15 EL=25.66 S GRADY W A Y LAKE AVE SRAINIER AVE SSDCHARGER CHARGER CHARGER CHARGER CHARGER CHARGER CHARGER TRANSFORMER CHARGER SWITCHGEAR CHARGER CHARGER CHARGER IT CHARGER PROPERTY LINE, TYP EXISTING ROW, TYP 1 EXISTING ROW, TYP 1 2 2 2 2 2 2 2 3 1 2 (TYP OF 6) 2 2 SDSD SD SD SDSDSD SD SD SDSDSDSDSDSDSD SD SD SD PARKING GARAGE 2 2 2HARDIEAVE SW3 POTENTIAL FUTURE TOD AREA N SCALE IN FEET 0 4020 8040 (1" = 40') CONTRACT UNIT DESCRIPTION 5 LANDSCAPING IRRIGATION PLANS SOUTH RENTON TRANSIT CENTER & RAINIER AVE S 405-LRP501 41 0 1" = 40' No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/03/22 | 12:27 PM | USDW675573C:\BMS\WSP-PB-US-PW-02\DAN.WOJTALA@WSP.COM\D0342984\BRT-405-LRP500.DWGBRT-405-LRP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/3/2022 GENERAL NOTES: 1.SEE SHEET 405-CXP501 FOR DEMOLITION AND REMOVAL PLAN. 2.SEE SHEET 405-CDP501 FOR DRAINAGE PLAN. 3.SEE SHEET 405-CPP501 FOR PAVING PLAN. 4.SEE SHEETS 405-CMP501 AND 405-TNP501 FOR PAVEMENT MARKING AND SIGNAGE PLANS. 5.SEE SHEETS 405-ELP501 FOR LIGHTING PLANS. 6.SEE SHEET 405-LHP501 FOR HARDSCAPE PLAN. 7.SEE SHEET 405-LPP501 FOR PLANTING PLAN. 8.SEE SHEET 405-UCP501 FOR UTILITY PLAN. CONSTRUCTION NOTES: 1 INSTALL IRRIGATION FOR LAWN AREAS PER THE SOUND TRANSIT DESIGN CRITERIA MANUAL 3 4" POP-UP LAWN SPRAY AND ROTOR IRRIGATION 6" POP-UP SHRUB SPRAY AND ROTOR IRRIGATION 2 LEGEND INSTALL IRRIGATION FOR SHRUB AND GROUND COVER AREAS PER THE SOUND TRANSIT DESIGN CRITERIA MANUAL INSTALL ROOT WATERING SYSTEM FOR TREES IN TREE GRATES AND PER THE SOUND TRANSIT DESIGN CRITERIA MANUAL 12345678910111213XXX XXX X H H H H H H BROADBAND VAULT 2VLTS T UNKNO W N U T I LSSSSSS GGFO FO FO FO EEEEEEEEEEEEE E E E E E E E FOFOFOWWWSSSSSSSSSSCOMCASTCOMCASTCOM C A S T COMCAST COMCAST COMCAST COMCAS T COMC A S TCOMCAST COMCASTCOMCASTCOMCASTCOM C A S T F O COMCAST CENTURYLINK FOCENTURY L I N K F O CENTUR Y L I N K F O CENTURY L I N K F O CENTUR Y L I N K F O CENTURYLINK FO2-PSE 2-PSE 2-PSE 2-PSE 2-PSE 2-PSE 2-PSE PSE PSE PSEPSEPSEPSEPSEPSE PSE PSEPSEPSEPSERENTONRENTONRENTONRENTONRENTONRENTONRENTONWSDOT FO2-ZAYO FO 2-ZAYO F O 2-ZAYO FOPSE GASPS E G A S PSE GAS PSE GASPS E G A S PSE GAS PSE GASPSE GAS PSE GASPSE GAS FO VLTCCCCCC BOREHOLE GA-10 EL=26.31 BOREHOLE SB-1 EL=27.17 BOREHOLE GA-14 EL=26.36 BOREHOLE P-14 EL=25.43 BOREHOLE GA-1 EL=25.09 BOREHOLE GA-2 EL=25.98 BOREHOLE RW10 EL=25.30 BOREHOLE GA-3 EL=25.97 BOREHOLE GA-4 EL=26.06 BOREHOLE SH-5 EL=26.22 BOREHOLE GA-8 EL=26.69 BOREHOLE GA-5 EL=27.71 BOREHOLE GA-7 EL=27.67 BOREHOLE GA-6 EL=27.90 BOREHOLE SB-2 EL=27.29 BOREHOLE GA12 EL=26.45 BOREHOLE GA-13 EL=26.06 BOREHOLE P-15 EL=25.66 S GRAD Y W A Y LAKE AVE SRAINIER AVE SSDSD SD SD SDSDSD SD SD SDSDSDSDSDSDSD SD SD SD405-C-RainierS405-C-G r a d y W 40 5 - C - H a r d i e S W CCPBPB PBPB PB 12+0014+0016+0075 0 + 0 0 75 0 + 0 0 156+00 158+00 160+00 11+47 10+00 19+ 2 6 10+00 12+ 0 0 14+0 0 16+00 18+ 0 0 17+65 10+00 12+0 0 14+00 16+00 9+ 5 1 10+ 0 0 12+ 0 0 14+00 16+00 18+00 18+30 14+70 9+75 10+0012+0014+00 N SCALE IN FEET 0 4020 8040 (1" = 40') CONTRACT UNIT DESCRIPTION 5 ELECTRICAL SITE ILLUMINATION PLAN SOUTH RENTON TC 405-ELP501 42 0 1" = 40' D. FOSTER D. FOSTER K. GRACE APPNo.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/09/22 | 1:11 PM | FOSTERDJC:\BMS\WSP-PB-US-PW-02\WSP__DUSTIN.FOSTER\D0342984\BRT-405-EPP500.DWGBRT-405-EPP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 CONSTRUCTION NOTES: PROVIDE AND INSTALL SITE LIGHTING LUMINAIRE IN LANDSCAPE/ HARDSCAPE AREA, INCLUDING FOUNDATION, POLE, FIXTURE AND ASSOCIATED CONDUIT AND WIRING. PROVIDE AND INSTALL SITE LIGHTING LUMINAIRE IN BUS LAYOVER AREA, INCLUDING FOUNDATION, POLE, FIXTURE AND ASSOCIATED CONDUIT AND WIRING. FOUNDATION MUST PROTRUDE A MINIMUM OF 3' ABOVE FINISHED GRADE. PROVIDE AND INSTALL CANOPY LIGHTING LUMINAIRE, SURFACE MOUNTED TO UNDERSIDE OF CANOPY, INCLUDING CONDUIT, WIRE, CONTROLS, AND MOUNTING HARDWARE. PROVIDE AND INSTALL FIXTURE WITH HOUSE SIDE SHIELD FOR AREA LIGHTING INSTALLED AT NORTH EDGE OF PROPERTY. 1 1 TYP. 2 2 2 2 DESCRIPTIONTYPE MANUFACTURER APPROVED EQUIVALENTS SOURCE TYPE CORRELATED COLOR TEMPERATURE (CCT) MIN. COLOR RENDERING INDEX(CRI) INITIAL LUMEN OUTPUT (LM) NOMINAL WATTAGE(W)VOLTAGE PL-01 LED AREA LIGHT MOUNTED ON 25' POLE. ALUMINUM HOUSING WITH POST-PAINTED POWDER COAT FINISH. TYPE III OPTICAL SYSTEM. 4000K CCT, MINIMUM 70 CRI, MINIMUM 31,000 LUMENS, MAXIMUM 263W. IP-66 RATING, UL LISTED FOR WET LOCATIONS. GARDCO P34 SERIES OR APPROVED EQUIVALENT LED 4000K 70 32,000 263 UNV SYMBOL PL-02 (2)LED AREA LIGHTS MOUNTED ON 25' POLE. ALUMINUM HOUSING WITH POST-PAINTED POWDER COAT FINISH. TYPE III OPTICAL SYSTEM. 4000K CCT, MINIMUM 70 CRI, MINIMUM 31,000 LUMENS, MAXIMUM 263W. IP-66 RATING, UL LISTED FOR WET LOCATIONS. GARDCO P34 SERIES OR APPROVED EQUIVALENT LED 4000K 70 64,000 526 UNV PL-03 CITY OF RENTON STANDARD STREETLIGHT. ALUMINUM HOUSING WITH POST-PAINTED POWDER COAT FINISH. FLAT GLASS LENS WITH TYPE II OPTICAL SYSTEM. 4000K CCT, MIN.70 CRI, MIN.16,000 LUMENS, MAX.140W. IP-67 RATING, UL LISTED FOR WET LOCATIONS. CYCLONE CY55P1A OR APPROVED EQUIVALENT LED 4000K 70 16,000 140 UNV SC-01 SURFACE MOUNTED FULLY ENCLOSED AND GASKTED 8' LED STRIP. FIBERGLASS HOUSING WITH STAINLESS STEEL LATCHES. FROSTED, RIBBED, IMPACT RESISTANT ACRYLIC LENS. 4000K CCT, MIN.80 CRI, MIN.8,000 LUMENS, MAX.52W. IP-67 RATING. H.E.WILLIAMS 96 SERIES OR APPROVED EQUIVALENT LED 4000K 80 8,000 95 UNV 3 3 TYP. 5 5 TYP. OF 8 X X UT H HH H H B R O ADB AND V AU L T T T CO UNK N O W N U T I L E E ESSSSSSSSSSSSSS SSSSSSSSSSSSSSFOFOFOFOE E E E EEEEEEEEEE E E /////// / ///// / / /// / //GG GG GGEEE GFO FOFOFOFOFOFO FO FO FO FOFOFOFOFOFOFOSS SS SS SS W W WWWWWWSD SDSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SS SS SS WWSD SD SD SD SD SDSSSSSSFOFOFO ESS SS SS COMCAST COMCAST COMCAST COMCAST COMCAST COMCAST COMCAST COMCAST COMCAST COMCAST COMCASTCOMCASTCOMC A S T COMC A S T COMC A S T COMC A S T COMCASTCOMCASTCOMC A S T COM C A S T COMCAST COMCAST COMC A S T COMCAST COMCAST FOCOMCAST CE N T U R Y L I N K F OCENTURYLINK FO CENTURY L I N K F O CENTU R Y L I N K F O CENTURYLI N K F O CENTU R Y L I N K F O CENTURYLINK FO CENT U R Y L I N K F OCENTURYLINK FOCENTURYLINK FOCENT U R Y L I N K F O CE N T U R Y L I N K F O CENTURYLINK FO CENTUR Y L I N K F O C E N T U R Y L I N K F O PSE PSE PSE PSE PSE 2-PSE 2-PSE 3-PSE PS E 2-PSE 3 -PSE 2 -PSE 2- P S E PSE PSE PSE PSE PSE PSE PSE PSE PSEPSEPSE PS E PSE PSE PSEPSERENTON RENTON RENTON RENTONRENTON RENTON RENTON RENTON RENT O N RENT O N RE N T O N RE N T O N REN T O N RENTONRENT O N RENTO N RENTONRENTO N RENTO N RENTON RENTON RENTON RENTON WSDO T F O WSDOT FOWSDOT FO2- Z A Y O F O PSE GAS PSE G A S PSE GAS PSE GAS PSE GAS PSE GASPSE GAS PSE GAS PSE GASPSE GAS PSE GAS PSE GASPSE GAS PSE G A S C C C C CCC BOREHO L E S B - 1 E L = 2 7 . 1 7 BO R EHO L EGA - 1 4 E L = 2 6 . 3 6 BO R EHO L E P - 1 4 E L = 2 5 . 4 3 B OR E H O L E P - 1 2 E L = 2 5 . 1 4 BOREHO L EGA - 1 E L = 2 5 . 0 9 B OR EHO LEGA - 2 E L = 2 5 . 9 8 BOREHO L ERW1 0EL = 2 5 . 3 0 BOREHO L E G A - 3EL = 2 5 . 9 7 BO R EHO L E SB - 2 E L = 2 7 . 2 9BOREHO L E G A 1 2EL = 2 6 . 4 5 BOREHO L E G A - 1 3 E L = 2 6 . 0 6 BOREHO L E P - 1 5 E L = 2 5 . 6 6 RAINIER A V E S SW 7TH ST PROPERTY LINE, TYP EXISTING ROW, TYP HARDI E A V E S W 4 0 5 -C -R a i n i e r S 405-C- H ar di e S W 4 0 5 - C -G r a d yW 405-C -SW7THST 10+09 12+0 0 14+00 16+00 18+00 20+00 22+00 747+ 0 0 748+ 0 0 750+00750+00150+00 1 5 2 + 0 0 248+001011+47 10+00 12+0010+00 12+009+5110+0012+00CONTRACT UNIT DESCRIPTION 5 ELECTRICAL ROADWAY ILLUMINATION PLAN RAINIER AVE S & HARDIE AVE SW IN RENTON 405-ELP502 43 0 1"=40'D. FOSTER D. FOSTER K. GRACE APPNo.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/09/22 | 1:14 PM | FOSTERDJC:\BMS\WSP-PB-US-PW-02\WSP__DUSTIN.FOSTER\D0342984\BRT-405-EPP500.DWGBRT-405-EPP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 N SCALE IN FEET 0 4020 8040 (1" = 40') S GR AD Y W A Y LIGHTING FIXTURE SCHEDULE: CONSTRUCTION NOTES: PROVIDE AND INSTALL DECORATIVE LUMINAIRE ON SIGNAL POLE. REFERENCE CITY OF RENTON STANDARD DETAIL 117.1. LUMINAIRE MUST MATCH EXISTING LIGHT FIXTURES INSTALLED IN THE VICINITY OF PROPOSED SIGNAL POLES. RELOCATE CITY OF RENTON DECORATIVE PEDESTRIAN LUMINAIRE. REFERENCE CITY OF RENTON STANDARD DETAIL 117.2. 4 6 6 4 4 DESCRIPTIONTYPE MANUFACTURER APPROVED EQUIVALENTS SOURCE TYPE CORRELATED COLOR TEMPERATURE (CCT) MIN. COLOR RENDERING INDEX(CRI) INITIAL LUMEN OUTPUT (LM) NOMINAL WATTAGE(W)VOLTAGE PL-01 LED AREA LIGHT MOUNTED ON 25' POLE. ALUMINUM HOUSING WITH POST-PAINTED POWDER COAT FINISH. TYPE III OPTICAL SYSTEM. 4000K CCT, MINIMUM 70 CRI, MINIMUM 31,000 LUMENS, MAXIMUM 263W. IP-66 RATING, UL LISTED FOR WET LOCATIONS. GARDCO P34 SERIES OR APPROVED EQUIVALENT LED 4000K 70 32,000 263 UNV SYMBOL PL-02 (2)LED AREA LIGHTS MOUNTED ON 25' POLE. ALUMINUM HOUSING WITH POST-PAINTED POWDER COAT FINISH. TYPE III OPTICAL SYSTEM. 4000K CCT, MINIMUM 70 CRI, MINIMUM 31,000 LUMENS, MAXIMUM 263W. IP-66 RATING, UL LISTED FOR WET LOCATIONS. GARDCO P34 SERIES OR APPROVED EQUIVALENT LED 4000K 70 64,000 526 UNV PL-03 CITY OF RENTON STANDARD STREETLIGHT. ALUMINUM HOUSING WITH POST-PAINTED POWDER COAT FINISH. FLAT GLASS LENS WITH TYPE II OPTICAL SYSTEM. 4000K CCT, MIN.70 CRI, MIN.16,000 LUMENS, MAX.140W. IP-67 RATING, UL LISTED FOR WET LOCATIONS. CYCLONE CY55P1A OR APPROVED EQUIVALENT LED 4000K 70 16,000 140 UNV SC-01 SURFACE MOUNTED FULLY ENCLOSED AND GASKTED 8' LED STRIP. FIBERGLASS HOUSING WITH STAINLESS STEEL LATCHES. FROSTED, RIBBED, IMPACT RESISTANT ACRYLIC LENS. 4000K CCT, MIN.80 CRI, MIN.8,000 LUMENS, MAX.52W. IP-67 RATING. H.E.WILLIAMS 96 SERIES OR APPROVED EQUIVALENT LED 4000K 80 8,000 95 UNV X XFO2-PSE CHARGER CHARGER CHARGER CHARGER CHARGER TRANSFORMER CHARGER SWITCHGEAR CHARGER CHARGER IT CHARGER SD SDPBPB PBXXX X H H H H H HEEEEE E CO FO FOFOFO FO FO F O 2VLTS T UNKNO W N U T I L OEOEOEOEOEOEOEOEOEOEOEOEOE OE OE OE OE OE OE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE OE OE OE OE OE OE OE OE OEOEOEOEOEOEOEOEOEOEOEOE OE OE OE OE OE OE OE OE OE OESSSSSSSSSS SSSSSSSSSSGGFO FO FO EEEEEEEEEE E E E E E FOFO FOFOFO FOFOWSSSSSSCENTURYLINK FOCENTURYL I N K F O CENTURY L I N K F O CENTURY L I N K F O CENTURY L I N K F O CENTURY L I N K F OPSEPSEPSEPSE2-PSE2-PSE 2-PSE 2-PSE 2-PSE 2-PSE 2-PSE PSE PSE PSEPSEPSEPSEPSE PSE PSEPSEPSEPSERENTONRENTONRENTONRENTONRENTONRENTONRENTONRENTONRENTONWSDOT FO2-ZAYO FOCCCCFOFOFOFOFOFOFOFOFOFOFOFOFO FO FO FO FO FO FO FO FO FO CHARGER CHARGER CHARGER CHARGER CHARGER CHARGER CHARGER TRANSFORMER CHARGER SWITCHGEAR CHARGER CHARGER CHARGER IT CHARGER 12+0014+0016+0075 0 + 0 0 75 0 + 0 0 158+00 160+00 11+47 10+00 19+ 2 6 10+00 12+ 0 0 14+0 0 16+00 18+0 0 17+65 10+00 12+0 0 14+00 16+00 9+5 1 10+ 0 0 12+ 0 0 14+00 16+00 18+00 18+30 14+70 9+75 10+0012+0014+00 SDSD SD SD SDSD SD SDSDSDSDSDSD SD 12345678910111213CC PBPB PBPB PBAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinCONSTRUCTION NOTES: 1 INSTALL TYPE 8 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.30-04. 2 NEW PULL BOX PER WSDOT STANDARD PLAN J-90.10-03. 3 INSTALL IT CLOSET FOR KC METRO WITHIN COMMUNICATION ROOM FOR METRO EQUIPMENT. 4 PROVIDE ELECTRICAL AND COMMUNICATION CONDUITS TO BEB CHARGERS AND GANTRY OF SIZE AND QUANTITY TO MEET THE REQUIREMENTS OF THE BEB MANUFACTURER ONCE SELECTED.AeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinGENERAL NOTES: 1.ELECTRICAL CONDUITS FROM THE SOUND TRANSIT AND METRO ELECTRICAL ROOMS TO THE STATION PLATFORM SHALL BE SIZED POST 30% TO SUPPORT LIGHTING ON THE PLATFORM AND SOUND TRANSIT AND METRO STATION AMENITIES AS LISTED ON DRAWINGS 405-JEP501-503 ONCE THE PLATFORM SHELTER AND AMENITY LOCATIONS ARE DESIGNED.AeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinNEW PULL BOX NEW JUNCTION BOX TYPE 8 NEW CONDUIT NEW METRO DATA CABINET EXISTING VAULT LEGEND: E PB IT FO EEEEEFOFOFOFOFOFOFOSSSSSSSSSSSSPSEPSE18'-0"3'-6"SYSTEMS STATION ELECTRICAL AND COMMUNICATION PLAN SOUTH RENTON TC 405-JEP501 44 0 1" = 50' SCALE IN FEET 025 5050 100 (1" = 50') NHARDIE AVE SWS GRADY W YRAINIER AVE SWLAKE AVE S___________________ JEP502 1 SOUTH RENTON TC PARKING GARAGE SOUTH RENTON TRANSIT CENTER PIC K - U P P L A T F O R M DROP-OFF PLATFORM CONTRACT UNIT DESCRIPTION 5 WIRING SCHEDULE RUN NO.CONDUIT SIZE CONDUCTORS REMARKS ST METRO 1 3" PVC COMM 1-12CT SMFO ST CONDUIT 3" PVC COMM SPARE ST CONDUIT 2 3" PVC COMM 1-12CT SMFO METRO CONDUIT 3" PVC COMM SPARE METRO CONDUIT 3 1" PVC COMM *BIKE LOCKERS 4 1" PVC COMM *ST CONDUIT 5 1" PVC COMM *METRO CONDUIT 1" PVC COMM *ST CONDUIT 6 PVC COMM**1-12CT SMFO METRO CONDUIT 7 PVC COMM***METRO CONDUIT 8 RGS ELEC***METRO CONDUIT 9 PVC ELEC***ST CONDUIT X METRO DATA CABINET No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/09/22 | 1:42 PM | XXLC:\BMS\WSP-PB-US-PW-02\XIAOYI.LIU@CONCORDENGR.COM\D0342984\BRT-405-JEP500.DWGBRT-405-JEP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 2 2 1 METRO COMM METRO COMM 6 1 1 1 5 5 *CONDUCTORS TO BE DETERMINED POST-30%. 2 2 2 METRO COMM 6 6 SCALE: 1"=10' 1 ST COMM 2 3 METRO 6 EXISTING JUNCTION BOX TO BE REMOVED. INTERCEPT AND EXTEND EXISTING CONDUITS TO CREATE CONTINUOUS CONDUIT PATHWAY. PULL BACK EXISTING 96-CT FIBER TRUNK CABLE FROM EXISTING 25-TA CABLE VAULT AT GRADY/RAINIER TO EXISTING 25-TA CABLE VAULT AT 7TH/RAINIER AND REINSTALL THROUGH NEW CABLE VAULT (RENTON) INTERCEPT EXISTING FIBER INTERCONNECT CONDUIT AND INSTALL NEW CABLE VAULT (RENTON) COMM VAULT FOR COMCAST CONNECTION (ST) ___________________ JEP503 1 ___________________ JEP504 1 ROW, TYP EASEMENT, TYP BEB GANTRY 3 BIKE LOCKERS 2 METRO COMM 2 METRO ELEC 7 7 88 8 2 METRO ELEC 6 4 4 4 6 8 1 2 1 2 1 METRO COMM **CONDUIT SIZE AND NUMBER OF CONDUIT IN THIS RUN WILL BE DETERMINED POST-30%. SCALE: 1"=20' 4 4 4 1 METRO ELEC 1 ST ELEC 9 8 8 9 9 8 1 ST ELEC 1 METRO ELEC 8 9 3 REFER TO ESP501 FOR ELECTRICAL CONNECTION TO GARAGE EEEEEE E E E E E EE E EEPSECCCCCCCFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOBUS BAY 1 SDSD1 1.6 2 3 4 5 6 7 269'-6"AeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinGENERAL NOTES: 1.PROVIDE ELECTRICAL AND COMMUNICATION CONDUITS AND JUNCTION BOXES WITHIN THE STATION PLATFORM AREA TO CONNECT TO THE SHELTERS, LIGHTING AND ITS AMENITIES LISTED ON THIS SHEET ONCE THE STATION PLATFORM DESIGN IS ADVANCED POST 30%. 2.SEPARATE ELECTRICAL AND COMMUNICATION CONDUITS AND JUNCTION BOXES SHALL BE PROVIDED SOUND TRANSIT AND FOR METRO. THE SIZE AND QUANTITY OF THE CONDUITS AND JUNCTION BOXES SHALL BE DETERMINED BASED ON THE FINAL LOCATION AND QUANTITIES OF ELEMENTS ON THE STATION PLATFORM WHEN THE DESIGN IS ADVANCED POST 30%. 3.ASSUME ELECTRICAL AND COMMUNICATION CONDUITS CONNECT TO A CLOSET/BUNGALOW LOCATED ON THE STATION PLATFORM FOR DISTRIBUTION TO STATION AMENITIES. SYSTEMS STATION ELECTRICAL AND COMMUNICATION PLAN SOUTH RENTON TC 405-JEP502 45 0 1" = 10' SCALE IN FEET 0 10 20510 (1" = 10') N PICK-UP PLATFORM CONTRACT UNIT DESCRIPTION 5 No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/09/22 | 1:43 PM | XXLC:\BMS\WSP-PB-US-PW-02\XIAOYI.LIU@CONCORDENGR.COM\D0342984\BRT-405-JEP500.DWGBRT-405-JEP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 MATCHLINE - SEE SHEET 405-JEP503ITS AMENITIES BUS BAY 1 (STRIDE BRT) CCTV CAMERAS PUBLIC ADDRESS PYLON VMS CANOPY VMS PUSH TO TALK TVM WAYSIDE VALIDATOR ngORCA CO FO FO FO FO FO FO FO FO FO FO FO FOFOFOFOFOFOFOFO 2 BLR D 3 BLR D OE OE E BUS B A Y 7 BUS BAY 2 BUS BAY 8 BUS B A Y 3 14+00 14+00 SDSDSDSDSD8 9 10 11 12 13AeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinGENERAL NOTES: 1.PROVIDE ELECTRICAL AND COMMUNICATION CONDUITS AND JUNCTION BOXES WITHIN THE STATION PLATFORM AREA TO CONNECT TO THE SHELTERS, LIGHTING AND ITS AMENITIES LISTED ON THIS SHEET ONCE THE STATION PLATFORM DESIGN IS ADVANCED POST 30%. 2.SEPARATE ELECTRICAL AND COMMUNICATION CONDUITS AND JUNCTION BOXES SHALL BE PROVIDED SOUND TRANSIT AND FOR METRO. THE SIZE AND QUANTITY OF THE CONDUITS AND JUNCTION BOXES SHALL BE DETERMINED BASED ON THE FINAL LOCATION AND QUANTITIES OF ELEMENTS ON THE STATION PLATFORM WHEN THE DESIGN IS ADVANCED POST 30%. 3.PROVIDE COMMUNICATION CONDUITS FOR ST CONNECTION FROM THE COMMUNICATION CLOSET/BUNGALOW TO THE BIKE LOCKERS SHOWN ON SHEET JEP504. 4.ASSUME ALL ELECTRICAL AND COMMUNICATION CONDUITS WITHIN THE STATION PLATFORM ARE DISTRIBUTED FROM A CLOSET/BUNGALOW LOCATED ON THE STATION PLATFORM TO STATION AMENITIES. SYSTEMS STATION ELECTRICAL AND COMMUNICATION PLAN SOUTH RENTON TC 405-JEP503 46 0 1" = 10' No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/09/22 | 1:44 PM | XXLC:\BMS\WSP-PB-US-PW-02\XIAOYI.LIU@CONCORDENGR.COM\D0342984\BRT-405-JEP500.DWGBRT-405-JEP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022 SCALE IN FEET 0 10 20510 (1" = 10') N CONTRACT UNIT DESCRIPTION 5MATCHLINE - SEE SHEET 405-JEP502ITS AMENITIES BUS BAY 2 (RAPIDRIDE)BUS BAY 3 (LOCAL)BUS BAY 7 (RAPIDRIDE)BUS BAY 8 (STRIDE BRT) CCTV CAMERAS CCTV CAMERAS CCTV CAMERAS CCTV CAMERAS PUBLIC ADDRESS PUBLIC ADDRESS PUBLIC ADDRESS PUBLIC ADDRESS METRO RTIS METRO RTIS PYLON VMS METRO PUSH TO TALK METRO PUSH TO TALK PUSH TO TALK METRO WAYSIDE VALIDATOR, ngORCA METRO WAYSIDE VALIDATOR, ngORCA TVM WAYSIDE VALIDATOR, ngORCA MATCHLINE - SEE SHEET 405-JEP504WIRING SCHEDULE RUN NO.CONDUIT SIZE CONDUCTORS REMARKS ST METRO 1 3" PVC COMM 1-12CT SMFO ST CONDUIT 3" PVC COMM SPARE ST CONDUIT 2 3" PVC COMM 1-12CT SMFO METRO CONDUIT 3" PVC COMM SPARE METRO CONDUIT 8 RGS ELEC***METRO CONDUIT 9 PVC ELEC***ST CONDUIT X 1 *CONDUCTORS TO BE DETERMINED POST-30%. 2 EXTEND CONDUITS TO COMMUNICATION CLOSET/BUNGALOW ON THE STATION PLATFORM ONCE LOCATION HAS BEEN IDENTIFIED POST 30%. PROVIDE SEPARATE SPACE FOR ST AND METRO EQUIPMENT. **CONDUIT SIZE AND NUMBER OF CONDUIT IN THIS RUN WILL BE DETERMINED POST-30%. 8 9 EXTEND CONDUITS TO ELECTRICAL CLOSET/BUNGALOW ON THE STATION PLATFORM ONCE LOCATION HAS BEEN IDENTIFIED POST 30%. PROVIDE SEPARATE SPACE FOR ST AND METRO EQUIPMENT. OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEBUS BAY 6 BUS BAY 5 BUS BAY 4 16+00AeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTinAeccDbSurfaceTin1.PROVIDE ELECTRICAL AND COMMUNICATION CONDUITS AND JUNCTION BOXES WITHIN THE STATION PLATFORM AREA TO CONNECT TO THE SHELTERS, LIGHTING AND ITS AMENITIES LISTED ON THIS SHEET ONCE THE STATION PLATFORM DESIGN IS ADVANCED POST 30%. 2.SEPARATE ELECTRICAL AND COMMUNICATION CONDUITS AND JUNCTION BOXES SHALL BE PROVIDED SOUND TRANSIT AND FOR METRO. THE SIZE AND QUANTITY OF THE CONDUITS AND JUNCTION BOXES SHALL BE DETERMINED BASED ON THE FINAL LOCATION AND QUANTITIES OF ELEMENTS ON THE STATION PLATFORM WHEN THE DESIGN IS ADVANCED POST 30%. 3.PROVIDE COMMUNICATION CONDUITS FOR ST CONNECTION FROM THE BIKE LOCKERS TO THE COMMUNICATION CLOSET/BUNGALOW NOTED ON SHEET JEP503. 4.ASSUME ALL ELECTRICAL AND COMMUNICATION CONDUITS WITHIN THE STATION PLATFORM ARE DISTRIBUTED FROM A CLOSET/BUNGALOW LOCATED ON THE STATION PLATFORM TO STATION AMENITIES. SYSTEMS STATION ELECTRICAL AND COMMUNICATION PLAN SOUTH RENTON TC 405-JEP504 47 0 1" = 10' SCALE IN FEET 0 10 20510 (1" = 10') N CONTRACT UNIT DESCRIPTION 5 No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV:LINE IS 1" ATFULL SCALEDESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY:02/09/22 | 1:45 PM | XXLC:\BMS\WSP-PB-US-PW-02\XIAOYI.LIU@CONCORDENGR.COM\D0342984\BRT-405-JEP500.DWGBRT-405-JEP500 FACILITY ID: PHASE 3 - 30% SUBMITTAL I-405 BRT AE 0054-17 02/11/2022PRELIMINARY 405 R. GORMAN 02/11/2022MATCHLINE - SEE SHEET 405-JEP503ITS AMENITIES BUS BAY 4 (LOCAL)BUS BAY 5 (LOCAL)BUS BAY 6 (LOCAL) CCTV CAMERAS CCTV CAMERAS CCTV CAMERAS PUBLIC ADDRESS PUBLIC ADDRESS PUBLIC ADDRESS BIKE LOCKER (TYP.) 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTSPRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:19 PM405 48 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZN501 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL GENERAL NOTES SOUTH RENTON TRANSIT CENTER CODES AND STANDARDS 1. 2018 INTERNATIONAL BUILDING CODE W/ WASHINGTON STATE AMENDMENTS 2. ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES 3. ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 4. TMS 402-16 BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES 5. AISC 360-16 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS 6. AISC 341-16 SEISMIC PROVISIONS FOR STEEL BUILDINGS 7. AWS D1.1 2010 STRUCTURAL WELDING CODE – STEEL 8. AWS D1.8 2009 STRUCTURAL WELDING CODE – SEISMIC SUPPLEMENT 9. RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH- STRENGTH BOLTS GENERAL 1. CONTRACTOR IS RESPONSIBLE FOR MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES REQUIRED TO PERFORM THE WORK. 2. CONTRACTOR-INITIATED CHANGES REQUIRE BOTH DESIGNER OF RECORD AND GOVERNMENT APPROVAL AND MUST BE SUBMITTED IN WRITING TO THE CONTRACTING OFFICER’S REPRESENTATIVE FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. 3. CONTRACTOR MUST VERIFY DIMENSIONS AND DETAILS PRIOR TO FABRICATION AND CONSTRUCTION. THIS INCLUDES, BUT IS NOT LIMITED TO, COORDINATING WITH THE CONTRACT DRAWINGS ON THE SIZE AND LOCATION OF OPENINGS THROUGH CONCRETE, VERIFYING SIZE AND LOCATION OF MECHANICAL AND ELECTRICAL OPENINGS WITH THE RESPECTIVE SUBCONTRACTOR, AS WELL AS COORDINATING INSERTS AND ATTACHMENTS FOR THE USE OF OTHER TRADES. 4. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. TYPICAL DETAILS AND NOTES SHOWN ON DRAWINGS APPLY UNLESS NOTED OTHERWISE. TYPICAL DETAILS MAY NOT NECESSARILY BE INDICATED ON THE PLANS BUT APPLY AS SHOWN OR DESCRIBED IN THE DETAILS. CONTRACTOR IS RESPONSIBLE FOR CHOOSING THE APPROPRIATE TYPICAL DETAIL FROM THOSE PROVIDED. THE CONTRACTOR MUST SUBMIT PROPOSED ALTERNATE DETAILS TO THOSE PROVIDED WITH RELATED CALCULATIONS TO THE ENGINEER FOR APPROVAL PRIOR TO DETAILING OR USE. 5. SHOP DRAWING REVIEW: BY SUBMITTING THE SHOP DRAWINGS, THE CONTRACTOR REPRESENTS THAT THEY HAVE DETERMINED AND VERIFIED MATERIALS, FIELD MEASUREMENTS, AND RELATED FIELD CONSTRUCTION CRITERIA (MEANS, METHODS, TECHNIQUES, SEQUENCES, OPERATIONS OF CONSTRUCTION, AND SAFETY PRECAUTIONS AND PROGRAMS INCIDENTAL THERETO), AND THAT THE CONTRACTOR HAS CHECKED AND COORDINATED THE INFORMATION CONTAINED WITHIN THE SUBMITTAL WITH THE REQUIREMENTS OF THE WORK AND THE CONTRACT DOCUMENTS. REVIEW BY THE ENGINEER DOES NOT RELIEVE THE CONTRACTOR FROM FULL RESPONSIBILITY FOR THE ACCURACY OF DIMENSIONS AND DETAILS. SUCH REVIEW DOES NOT CONSTITUTE ACCEPTANCE BY THE ENGINEER OF THE CORRECTNESS OR ADEQUACY OF SUCH SUBMITTALS, NOR A WARRANTY THAT THE SUBMITTALS SATISFY THE REQUIREMENTS OF THE CONTRACT. DESIGN LOADS DEAD LOADS: WEIGHT OF MATERIALS OF CONSTRUCTION AND PERMANENT EQUIPMENT. SUPERIMPOSED DEAD LOADS: MECHANICAL, ELECTRICAL & PLUMBING 5 PSF LIVE LOADS GARAGE FLOOR 50 PSF GARAGE ROOF 50 PSF RISK CATEGORY II SNOW LOAD SNOW LOAD IMPORTANCE FACTOR, Is 1.0 GROUND SNOW LOAD 25 PSF EXPOSURE FACTOR, Ce 1.0 THERMAL FACTOR, Ct 1.2 ROOF SNOW LOAD 25 PSF WIND LOADS BASIC WIND SPEED (3-SECOND GUST), Vult 97 MPH NOMINAL WIND SPEED, Vasd = Vult* sqrt(0.6) 75 MPH WIND EXPOSURE C SEISMIC LOADS SEISMIC IMPORTANCE FACTOR, Ie 1.0 SITE LATITUDE AND LONGITUDE 47.47179° N, 122.21658° W MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS SHORT PERIOD, Ss 1.44g 1 SECOND PERIOD, S1 0.49g SITE CLASS E DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS SHORT PERIOD, SDS TBD* 1 SECOND PERIOD, SD1 TBD* *A SITE SPECIFIC GROUND MOTION HAZARD ANALYSIS TO BE PERFORMED AT LATER DATE SEISMIC DESIGN CATEGORY D BASIC SEISMIC-FORCE-RESISTING SYSTEM SPECIAL REINFORCED CONCRETE MOMENT FRAME RESPONSE MODIFICATION FACTOR, R 8 OVERSTRENGTH FACTOR, Ω0 3.0 DEFLECTION AMPLIFICATION FACTOR, Cd 5.5 SEISMIC RESPONSE COEFFICIENT, CS TBD DESIGN BASE SHEAR TBD KIPS ANALYSIS PROCEDURE USED TBD FOUNDATIONS 1. FOUNDATION DESIGN IS BASED ON THE SOUTH RENTON TRANSIT CENTER GEOTECHNICAL RECOMMENDATION REPORT - DRAFT, DATED NOVEMBER 2021 2. FOUNDATION WORK MUST BE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THIS REPORT, AND THE CONTRACTOR MUST BE FAMILIAR WITH THIS REPORT. 3. SPECIAL INSPECTION MUST BE PERFORMED DURING FOUNDATION WORK TO CONFIRM THAT EXISTING CONDITIONS COMPLY WITH CONDITIONS IN THE GEOTECHNICAL REPORT. 4. PIER DESIGN IS BASED ON 70 FOOT LONG PIER WITH AN ALLOWABLE CAPACITY OF 400 KIPS (COMBINED SIDE AND TIP RESISTANCE). STRUCTURAL CONCRETE 1. CONCRETE WORK MUST CONFORM TO REQUIREMENTS OF ACI 301, SPECIFICATIONS FOR STRUCTURAL CONCRETE. 2. DESIGN MIXES FOR THE FOLLOWING CLASSES OF CONCRETE, MUST BE PROPORTIONED TO PROVIDE THE SPECIFIED COMPRESSIVE STRENGTH. FOUNDATIONS 4,000 PSI SLAB-ON-GROUND 4,000 PSI P/T SLABS AND BEAMS 6,000 PSI WALLS 5,000 PSI COLUMNS 6,000 PSI MOMENT FRAME BEAMS 6,000 PSI 3. SLAB-ON-GRADE CONCRETE FLEXURAL STRENGTH 650 PSI AT 90 DAYS 4. STEEL REINFORCEMENT MUST CONFORM TO THE FOLLOWING STANDARDS AND SPECIFIED STRENGTH. DEFORMED BARS (A615) Fy = 60,000 PSI DEFORMED BARS (A706) Fy = 60,000 PSI WELDED WIRE REINF (A1064) Fy = 60,000 PSI PRESTRESSING STRAND (A416) Fu = 270,000 PSI 5. TYPICAL DETAILS OF REINFORCEMENT SUCH AS HOOKS, BEND DIAMETERS, ETC. MUST BE IN ACCORDANCE WITH ACI SP-66 – “ACI DETAILING MANUAL”. 6. REINFORCEMENT MARKED "CONT" (CONTINUOUS) MUST BE SPLICED BY LAPPING OR WITH MECHANICAL CONNECTORS. LAP LENGTH NOTES: A. SEE DEVELOPMENT AND LAP SPLICE LENGTH SCHEDULE FOR REINFORCED CONCRETE B. LAP SPLICES OF WELDED WIRE REINFORCEMENT MUST HAVE A LENGTH OF LAP EQUAL TO THE GREATER OF 1.5X WIRE DEVELOPMENT LENGTH OR ONE CROSSWIRE SPACING PLUS 2 INCHES. C. MECHANICAL CONNECTORS MUST HAVE A MINIMUM CAPACITY OF 1.25 X YIELD STRENGTH OF THE BAR. D. IN MEMBERS DESIGNATED AS PART OF THE SEISMIC-FORCE-RESISTING SYSTEM, MECHANICAL CONNECTORS MUST HAVE A MINIMUM CAPACITY EQUAL TO THE TENSILE STRENGTH OF THE BAR. 7. MECHANICAL REBAR ANCHORS (TERMINATORS) MUST BE THREADED DEVICES WITH A CAPACITY GREATER THAN THE YIELD STRENGTH OF THE BAR. 8. REFER TO ARCHITECTURAL, ELECTRICAL, MECHANICAL, AND STRUCTURAL DRAWINGS FOR SURFACE FEATURES AND INSERTS, TO BE CAST IN CONCRETE AND FOR LOCATIONS OF PENETRATIONS FOR PIPES, DUCTS, CONDUITS, ETC. 9. CONCRETE COVER FOR REINFORCEMENT STEEL IN CAST-IN-PLACE NON-PRESTRESSED CONCRETE MEMBERS MUST BE AS FOLLOWS, UNLESS NOTED OTHERWISE. 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTSPRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:19 PM405 49 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZN502 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL GENERAL NOTES SOUTH RENTON TRANSIT CENTER MASONRY 1. MASONRY WORK MUST CONFORM TO REQUIREMENTS OF TMS 602-16, SPECIFICATIONS FOR MASONRY STRUCTURES. 2. PROVIDE LEVEL B QUALITY ASSURANCE AND SPECIAL INSPECTION PER TMS 602-16. 3. CONCRETE MASONRY: SPECIFIED COMPRESSIVE STRENGTH, f’m = 2,000 PSI AS DETERMINED PER ARTICLE 1.4B OF TMS 602-16. THE SPECIFIED COMPRESSIVE STRENGTH MUST BE VERIFIED PRIOR TO START OF CONSTRUCTION. 4. CONCRETE MASONRY UNITS MUST BE MEDIUM WEIGHT AND HAVE A MINIMUM NET AREA COMPRESSIVE STRENGTH = 2,000 PSI AS DETERMINED PER ASTM C90. 5. UNITS MUST BE LAID UP IN RUNNING BOND UNLESS NOTED OTHERWISE. THICKNESS OF BED JOINTS MUST NOT EXCEED 5/8 INCH. USE BOND BEAM UNITS AT HORIZONTAL REINFORCING. 6. MORTAR MUST BE TYPE S CONFORMING TO ASTM C270 WITH f’m = 1,800 PSI. MASONRY CEMENT MORTAR MUST NOT BE USED. 7. STEEL REINFORCEMENT MUST CONFORM TO ASTM A615, GRADE 60. WELDED REINFORCING STEEL MUST CONFORM TO ASTM A706, GRADE 60. 8. CONTINUOUS REINFORCING STEEL MUST BE LAP SPLICED IN ACCORDANCE WITH THE DEVELOPMENT AND LAP SPLICE LENGTH FOR CMU SCHEDULE. MECHANICAL SPLICES, WHERE NOTED, MUST BE THREADED COUPLERS FOR TAPERED THREADED OR UPSET THREADED BARS CERTIFIED TO DEVELOP 1.25 x Fy. SIMILARLY, TERMINATORS MUST BE THREADED DEVICES TO FULLY ANCHOR THE YIELD STRENGTH OF BAR. 9. CENTER VERTICAL REINFORCING IN WALL UNLESS NOTED OTHERWISE. WHERE REQUIRED, VERTICAL BAR POSITIONERS MUST BE USED TO SECURE VERTICAL REINFORCING AGAINST DISPLACEMENT PRIOR TO GROUTING. 10. PROVIDE VERTICAL BARS FULL HEIGHT AT WALL CORNERS, DOORS, WINDOWS AND OTHER OPENINGS. PROVIDE CONTINUOUS HORIZONTAL REINFORCEMENT AT CORNERS. PROVIDE HORIZONTAL REINFORCEMENT ABOVE DOOR OPENINGS, ABOVE AND BELOW WINDOWS AND OTHER OPENINGS. EXTEND REINFORCEMENT Ld BEYOND EACH SIDE OF OPENING UNLESS NOTED OTHERWISE. OPENINGS FOR DUCTS AND PIPES PENETRATING MASONRY WALLS MUST BE VERIFIED AND COORDINATED WITH MECHANICAL AND ELECTRICAL CONTRACTOR'S REQUIREMENTS. PENETRATIONS THROUGH WALLS MUST HAVE ADDITIONAL REINFORCING WHERE SHOWN. 11. GROUT MUST CONFORM TO ASTM C476, WITH MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2,000 PSI. GROUT SLUMP AT TIME OF GROUTING MUST BE 8 TO 11 INCHES. WATER REDUCING ADMIXTURES MAY BE ADDED TO ACHIEVE THE DESIRED SLUMP. 12. FINE GROUT OR COARSE GROUT MUST BE SELECTED BASED ON MINIMUM GROUT SPACE REQUIREMENTS OF TABLE 7 OF TMS 602-16. 13. HIGH LIFT GROUTING (LIFT HEIGHT GREATER THAN 5’-4”): ONLY ALLOWED WITH PRIOR WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER OF RECORD AND THE CONTRACTING OFFICER REPRESENTATIVE. THE MASONRY CONTRACTOR MUST REQUEST WRITTEN APPROVAL A MINIMUM OF TEN (10) DAYS PRIOR TO PROCEEDING WITH SITE MOBILIZATION. THE MASONRY CONTRACTOR MUST SUBMIT QUALIFICATIONS TO PERFORM HIGH LIFT GROUTING ADDRESSING EACH OF THE FOLLOWING ITEMS AND OTHERS THEY DEEM IMPORTANT WITHIN THE WRITTEN SUBMISSION. A. REFERENCE: ARTICLE 3.5 OF TMS 602-16. B. UNIT AND GROUTING CREWS MUST HAVE A MINIMUM OF FIVE (5) YEARS SUCCESSFUL COMMERCIAL BUILDING EXPERIENCE WITH SIMILAR HIGH LIFT GROUTING PROJECTS. LIST THREE PROJECTS WITH A CONTACT FOR EACH. C. A LIFT MUST NOT EXCEED ONE STORY LEVEL, OR 12’-8” MAXIMUM. 14. CONTROL JOINTS: A. CONCRETE MASONRY WALL CONTROL JOINTS SPACED AT A MAXIMUM OF 30 FEET ON CENTER, THREE TIMES THE WALL HEIGHT, OR AS OTHERWISE SHOWN ON THE DRAWINGS. B. MASONRY VENEER CONTROL JOINTS SPACED AT A MAXIMUM OF 20 FEET ON CENTER OR AS OTHERWISE SHOWN ON THE DRAWINGS. 15. COORDINATE WITH ARCHITECTURAL DRAWINGS FOR THE LOCATION, EXTENT AND ORIENTATION OF CMU BLOCKS WITH REGARD TO COLOR, FINISH OR ORIENTATION. 16. COLD AND HOT WEATHER CONSTRUCTION MUST BE IN ACCORDANCE WITH ARTICLE 1.8C AND ARTICLE 1.8D RESPECTIVELY OF TMS 602-16. CONCRETE EXPOSURE CAST AGAINST AND PERMANENTLY IN CONTACT WITH GROUND EXPOSED TO WEATHER OR IN CONTACT WITH GROUND NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND MEMBER ALL ALL SLABS, JOISTS AND WALLS BEAMS, COLUMNS, PEDESTALS, AND TENSION TIES REINFORCEMENT ALL #6 THRU #18 BAR #5 BAR, W31 OR D31 WIRE, AND SMALLER #14 AND #18 BARS #11 BAR AND SMALLER PRIMARY REINFORCEMENT, STIRRUPS, TIES, SPIRALS AND HOOPS SPECIFIED COVER (INCHES) 3 2 1-1/2 1-1/2 3/4 1-1/2 ACI 318-14 TABLE 20.6.1.3.1---SPECIFIED CONCRETE COVER FOR CAST-IN-PLACE NONPRESTRESSED CONCRETE MEMBERS CONCRETE EXPOSURE CAST AGAINST AND PERMANENTLY IN CONTACT WITH GROUND EXPOSED TO WEATHER OR IN CONTACT WITH GROUND NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND MEMBER ALL SLABS, JOISTS AND WALLS ALL OTHER SLABS, JOISTS AND WALLS BEAMS, COLUMNS, AND TENSION TIES REINFORCEMENT ALL ALL ALL ALL PRIMARY STIRRUPS, TIES, SPIRALS AND HOOPS SPECIFIED COVER (INCHES) 3 1 1-1/2 3/4 1-1/2 1 ACI 318-14 TABLE 20.6.1.3.2---SPECIFIED CONCRETE COVER FOR CAST-IN-PLACE PRESTRESSED CONCRETE MEMBERS CONCRETE EXPOSURE EXPOSED TO WEATHER OR IN CONTACT WITH GROUND NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND MEMBER WALLS ALL OTHER SLABS, JOISTS AND WALLS BEAMS, COLUMNS, PEDESTALS AND TENSION TIES REINFORCEMENT #14 AND #18 BARS; TENDONS LARGER THAN 1-1/2"Ø #11 AND SMALLER; W31 AND D31 WIRE AND SMALLER; TENDONS AND STRANDS 1-1/2"Ø AND SMALLER #14 AND #18; TENDONS LARGER THAN 1-1/2"Ø #6 THRU #11 BARS; TENDONS AND STRANDS LARGER THAN 5/8"Ø THRU 1-1/2"Ø #5 BAR, W31 OR D31 WIRE, AND SMALLER; TENDONS AND STRANDS 5/8"Ø AND SMALLER #14 AND #18 BARS; TENDONS LARGER THAN 1-1/2"Ø TENDONS AND STRANDS 1-1/2"Ø (INCL) AND SMALLER #11 BAR, W31 AND D31 WIRE, AND SMALLER PRIMARY REINFORCEMENT STIRRUPS, TIES, SPIRALS AND HOOPS SPECIFIED COVER (INCHES) 1-1/2 3/4 2 1-1/2 1-1/4 1-1/4 3/4 5/8 GREATER OF db AND 5/8 AND NEED NOT EXCEED 1-1/2 3/8 ACI 318-14 TABLE 20.6.1.3.3---SPECIFIED CONCRETE COVER FOR PRECAST NONPRESTRESSED OR PRESTRESSED CONCRETE MEMBERS MANUFACTURED UNDER PLANT CONDITIONS POST TENSIONED CAST-IN-PLACE CONCRETE 1. TENDONS ARE COMPRISED OF SEVEN-WIRE STRAND CONFORMING TO ASTM A416 WITH A MINIMUM ULTIMATE TENSILE STRENGTH OF 270 KSI. WIRE MUST BE LOW RELAXATION, UNCOATED, CLEAN, AND FREE OF CORROSION. STRAND DIAMETER HAS BEEN ASSUMED TO BE 0.5 INCH. IF 0.6 INCH IS USED, SUBMIT CALCULATIONS FOR APPROVAL WITH SHOP DRAWINGS. ONLY ONE STRAND SIZE MUST BE USED THROUGHOUT THE JOB. JACK TO 0.80 FPU MAXIMUM. 2. MULTI STRAND TENDONS IN BEAMS. PROVIDE THE MINIMUM NUMBER OF 0.5 INCH OR 0.6 INCH DIAMETER STRAND FOR EFFECTIVE FORCE NOTED. STRESS TO ACHIEVE INDICATED FORCE. SUBMIT FRICTION AND LOSS CALCULATIONS PRIOR TO PREPARATION OF SHOP DRAWINGS. (MAXIMUM EFFECTIVE STRESS FOR STRAND FORCE CALCULATION MUST BE 165 KSI). 3. ANCHORAGE PROVIDED MUST BE LIMITED TO THOSE WITH A MAXIMUM SEATING LOSS OF ¼ INCH, SUCH AS MANUFACTURED BY VSL CORPORATION OR APPROVED EQUAL. 4. RECORD MUST BE KEPT OF JACKING FORCES AND TENDON ELONGATIONS. IF ACTUAL ELONGATION AND CALCULATED ELONGATIONS ARE NOT IN AGREEMENT WITHIN 5%, THE ENGINEER MUST BE NOTIFIED PRIOR TO BURNING OFF TENDON TAIL OR GROUTING. ELONGATIONS MUST BE CALCULATED BASED ON THE ACTUAL MODULUS OF ELASTICITY OF THE TENDONS SUPPLIED AS SHOWN ON THE MILL CERTIFICATE. 5. UNBONDED TENDONS MUST HAVE A CONTINUOUS WATER RESISTANT SHEATH TO PREVENT INTRUSION OF CEMENT PASTE AND THE ESCAPE OF THE CORROSION RESISTANT COATING. REPAIR ANY DAMAGE TO THE SHEATH AND RECOAT STRAND BEFORE PLACING CONCRETE. ANCHORS MUST BE EPOXY COATED. 6. DUCT-FORMING MATERIAL FOR GROUTED MULTI STRAND TENDONS MUST BE STRONG ENOUGH TO RETAIN ITS SHAPE AND RESIST DAMAGE CONSTRUCTION. IT MUST PREVENT THE ENTRANCE OF CEMENT PASTE AND WATER FROM THE CONCRETE. THE DUCT MUST BE VENTED AS REQUIRED TO ENSURE NO VOIDS ARE PRESENT AFTER GROUTING. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. THE FOLLOWING FRICTION AND WOBBLE COEFFICIENTS WERE ASSUMED: BONDED TENDONS UNBONDED TENDONS Μ = 0.20 / RAD Μ = 0.05 /RAD K = 0.0002 / ft K = 0.0014 / ft 7. GROUTED TENDONS MUST BE PRESSURE GROUTED IMMEDIATELY AFTER ACCEPTANCE OF TENSIONING. GROUT FOR TENDON MUST CONSIST OF A MIXTURE OF CEMENT AND WATER. 8. SEE PLANS FOR AREAS THAT REQUIRE STRAND MARKERS. 9. IT MUST BE THE CONTRACTOR’S RESPONSIBILITY TO MAINTAIN THE ALIGNMENT OF THE TENDONS BEFORE, DURING, AND AFTER CONCRETE PLACEMENT. 10. COMPLETE SHOP DRAWINGS OF THE POST-TENSIONING SYSTEM MUST BE SUBMITTED FOR APPROVAL BY THE ENGINEER AND REVISED PRIOR TO INSTALLING THE POST-TENSIONING. 11. THE DRAWINGS SHOW THE VSL SYSTEM. OTHER TENSIONING SYSTEMS SATISFYING THE LIMITATIONS OF FINAL FORCE, GEOMETRY, TENDON SPACING AND PROFILE, AND END DETAILS MAY BE SUBMITTED FOR APPROVAL. 12. SPECIAL JACKS MAY BE REQUIRED FOR STRESSING TEMPERATURE STRANDS AT RAMP LOCATIONS (SEE PLANS). 13. STRESSING SEQUENCE; STRESS THE FLOOR SYSTEM IN THE FOLLOWING SEQUENCE: A. SLABS - FIRST B. BEAMS - NEXT C. GIRDERS - LAST 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTSPRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:19 PM405 50 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZN503 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL GENERAL NOTES SOUTH RENTON TRANSIT CENTER STRUCTURAL STEEL 1. STEEL CONSTRUCTION MUST CONFORM TO AISC 360-16 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS AND AISC 341-16 SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS. 2. STEEL MUST CONFORM TO THE FOLLOWING: 3. WORK MUST BE IN ACCORDANCE WITH AISC 303, AS MODIFIED PER THE PROJECT SPECIFICATIONS. 4. HOLES IN STEEL CUT IN THE FIELD MUST BE DRILLED, NOT BURNED. 5. CAMBER BEAMS AS NOTED ON THE FRAMING PLANS. WHERE NO CAMBER IS NOTED, FABRICATE BEAMS SO THAT THE CAMBER AS ROLLED (WITHIN ALLOWABLE TOLERANCES) IS POSITIVE. WIND GIRTS WITH INCIDENTAL CAMBER MUST BE INSTALLED WITH CAMBER POSITIVE TO THE BUILDING EXTERIOR. 6. STEEL BEAMS ARE EQUALLY SPACED BETWEEN DIMENSION POINTS UNO. 7. MINIMUM CONNECTION MUST BE A TWO-BOLT CONNECTION USING 7/8-INCH DIAMETER GRADE A325 BOLTS (TYPE N) IN SINGLE SHEAR. 8. HIGH-STRENGTH BOLTS MUST BE INSTALLED, TIGHTENED, AND INSPECTED IN ACCORDANCE WITH IBC AND RCSC SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH-STRENGTH BOLTS. THE CRITERIA FOR SNUG-TIGHT CONNECTIONS APPLIES TO CONNECTIONS UNLESS NOTED OTHERWISE AS SLIP-CRITICAL. 9. BOLTS IN BEAM-TO-BEAM/GIRDER MAY BE SNUG TIGHT, UNLESS SPECIFICALLY CALLED OUT AS SLIP CRITICAL. CONTRACTOR MUST SUBMIT TIGHTENING PROCEDURES TO THE ENGINEER FOR REVIEW AND APPROVAL. 10. HEADED STUD ANCHORS (HSA) FOR COMPOSITE AND NON-COMPOSITE CONSTRUCTION A. HEADED STUD ANCHORS MUST BE ¾ INCH DIAMETER, TYPE B, CONFORMING TO AWS D1.1, UNLESS NOTED OTHERWISE. B. HEADED STUD ANCHORS MUST BE AUTOMATICALLY END WELDED IN SHOP OR FIELD WITH EQUIPMENT RECOMMENDED BY STUD MANUFACTURER. C. WELDING, AND INSPECTION MUST BE IN ACCORDANCE WITH AWS D1.1. 11. STEEL ANCHORS, TIES AND OTHER MEMBERS EMBEDDED IN CONCRETE OR MASONRY MUSTL BE LEFT UNPAINTED AT INTERIOR, UNEXPOSED CONDITIONS. 12. ITEMS EMBEDDED IN CONCRETE OR MASONRY AND EXPOSED TO EARTH OR WEATHER MUST BE HOT-DIPPED GALVANIZED (UNLESS NOTED OTHERWISE): A. CONCRETE & MASONRY ACCESSORIES OF FERROUS MATERIAL INCLUDING: INSERTS, EMBEDS, AND BRACKETS. B. PIPE GUARDS, BOLLARDS AND HARDWARE FOR SAME. C. WHERE NOTED AS "GALV". 13. LOCATIONS OF EMBEDDED ITEMS MUST BE COORDINATED WITH VENDOR'S SHOP DRAWINGS. 14. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE SELECTION OF OPTIONAL DETAILS SHOWN ON THE DRAWINGS. 15. THE CONTRACTOR IS RESPONSIBLE FOR ERECTION AIDS THAT INCLUDE, BUT ARE NOT LIMITED TO, ERECTION ANGLES, LIFT HOLES, AND OTHER AIDS. REMOVE ERECTION AIDS, INCLUDING ERECTION BOLTS. PLUG WELD HOLES AND GRIND SMOOTH. 16. MEANS AND METHODS OF ERECTION ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND CONNECTIONS AND DETAILS DO NOT NECESSARILY SHOW ERECTION AIDS REQUIRED. STRUCTURAL STEEL WELDING 1. WELDING MUST BE DONE BY CERTIFIED WELDERS AND IN ACCORDANCE WITH AWS D1.1 AND D1.8. 2. WELD SIZES SHOWN ON THE DRAWINGS ARE MINIMUM AND EFFECTIVE SIZES. INCREASE WELD SIZE TO AWS/AISC MINIMUM SIZES AS REQUIRED FOR CONNECTION MATERIAL. THE MINIMUM WELD SIZE MUST BE 3/16 INCHES (EFFECTIVE). 3. FIELD WELDING SYMBOLS HAVE NOT NECESSARILY BEEN INDICATED ON THE DRAWINGS. WHERE NO FIELD WELDING IS DETAILED ON THE DRAWINGS, IT IS THE CONTRACTOR’S RESPONSIBILITY TO COORDINATE THE USE OF SHOP AND FIELD WELDS. 4. PARTIAL JOINT PENETRATION (PJP) GROOVE WELDS SHOWN ON THE DRAWINGS REFER TO EFFECTIVE THROAT THICKNESS. COMPLETE JOINT PENETRATION (CJP) WELDS MUST BE ULTRASONICALLY TESTED (UT) UPON COMPLETION OF THE CONNECTION, EXCEPT PLATE LESS THAN OR EQUAL TO 5/16 INCH THICK MUST BE MAGNETIC PARTICLE TESTED (MT). 5. WELDS MUST BE MADE USING LOW HYDROGEN ELECTRODES WITH TENSILE STRENGTH PER AWS D1.1 AND D1.8 (MINIMUM 70 KSI). 6. WELDING MUST BE PERFORMED IN STRICT ADHERENCE TO A WRITTEN WELDING PROCEDURE SPECIFICATION (WPS) PER AWS D1.1 AND D1.8. WELDING PROCEDURES MUST BE SUBMITTED TO THE ENGINEER FOR REVIEW BEFORE STARTING FABRICATION OR ERECTION. COPIES OF THE WPS MUST BE ON SITE AND AVAILABLE TO WELDERS AND THE SPECIAL INSPECTOR. 7. WELDS THAT ARE PART OF THE SEISMIC FORCE-RESISTING SYSTEM MUST HAVE A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20 FOOT-POUNDS AT 0 DEGREES FAHRENHEIT. SHAPE WIDE FLANGES ANGLE & CHANNEL UNO PLATE & BAR STOCK PIPE SQUARE OR RECTANGULAR TUBE (HSS) ROUND TUBE (HSS) OTHER STEEL (UNO) ASTM SPECIFICATION A992 A36 A572 GARDE 50 A53 GRADE B A500 GRADE B A500 GRADE B A572 YIELD STRENGTH, Fy (KSI) 50 36 50 35 46 42 50 ANCHOR RODS 1. ANCHOR RODS MUST BE ASTM F1554 GRADE 55, UNLESS NOTED OTHERWISE. FURNISH ANCHOR RODS PREFABRICATED WITH MATCHING DOUBLE HEAVY HEX NUTS JAMMED AT THE END EMBEDDED IN CONCRETE. FURNISH HARDENED PLATE WASHERS, DOUBLE HEAVY HEX NUTS FOR SECURING THE BASE PLATE TO THE ANCHOR RODS. 2. PLATE WASHERS MUST BE WELDED ALL AROUND WHERE AISC OVERSIZED HOLES ARE USED AT BASE PLATES. 3. A RIGID STEEL TEMPLATE MUST BE USED TO LOCATE ANCHOR RODS WHILE PLACING CONCRETE. 4. ANCHOR RODS MUST HAVE SUFFICIENT LENGTH TO PROVIDE THE MINIMUM EMBEDMENT SHOWN ON THE DRAWINGS (MEASURED FROM THE FACE OF CONCRETE) WITH ADEQUATE EXTENSION AS REQUIRED TO RECEIVE THE GROUT PAD, BASE PLATE, AND FULL THREAD PROJECTION FOR NUT INSTALLATION + 1/2” ABOVE THE INSTALLED NUTS. 5. ANCHOR ROD INSTALLATION MUST BE COORDINATED WITH REINFORCING AND FORMWORK. AFTER BASE INSTALLATION, ANCHOR ROD NUTS MUST BE INSTALLED TO A FULLY-TIGHT CONDITION UNLESS NOTED OTHERWISE. 6. NO HEATING OR BENDING OF THE ANCHOR RODS IS PERMITTED. NON-SHRINK GROUT 1. NON-SHRINK GROUT MUST BE CEMENTITIOUS HIGH PRECISION, NATURAL AGGREGATE, NON-METALLIC, NON-STAINING, NON-SHRINKABLE GROUT CONFORMING TO ASTM C1107 AND CRD-C 621, CORPS OF ENGINEERS "SPECIFICATIONS FOR NON-SHRINK GROUT." GROUT MUST HAVE A SPECIFIED MINIMUM COMPRESSIVE STRENGTH OF 8,000 PSI AT 5 DAYS. PRE-GROUTING OF BASE PLATES IS NOT PERMITTED. ANCHORAGE TO CONCRETE AND MASONRY 1. EXCEPT WHERE INDICATED ON THE DRAWINGS, POST-INSTALLED ANCHORS CONSIST OF THE FOLLOWING ANCHOR TYPES. 2. ANCHOR CAPACITY USED IN DESIGN MUST BE BASED ON THE TECHNICAL DATA PUBLISHED IN THE ICC APPROVAL REPORT. SUBSTITUTION REQUESTS MUST INCLUDE ICC ESR REPORT SHOWING COMPLIANCE WITH RELEVANT BUILDING CODE AND INSTALLATION CATEGORY AND BE APPROVED IN WRITING BY THE CONTRACTING OFFICER’S REPRESENTATIVE/ENGINEER OF RECORD PRIOR TO USE. 3. INSTALL ANCHORS PER THE MANUFACTURER INSTRUCTIONS, AS INCLUDED IN THE ANCHOR PACKAGING. 4. ANCHOR CAPACITY IS DEPENDENT UPON SPACING BETWEEN ADJACENT ANCHORS AND EDGE DISTANCE. INSTALL ANCHORS IN ACCORDANCE WITH SPACING AND EDGE CLEARANCES INDICATED ON THE DRAWINGS. 5. EXISTING CONSTRUCTION: EXISTING REINFORCING BARS IN THE STRUCTURE MAY CONFLICT WITH SPECIFIC ANCHOR LOCATIONS. UNLESS NOTED OTHERWISE ON THE DRAWINGS, THE CONTRACTOR MUST LOCATE THE POSITION OF THE EXISTING REINFORCING BARS AND AVOID CUTTING. DRILLED-IN SCREW ANCHORS INTO CONCRETE 1. HILTI KWIK HUS-EZ SCREW ANCHORS PER ICC ESR-3027 2. SIMPSON TITEN HD SCREW ANCHOR PER ICC ESR-2713 3. DEWALT SCREW BOLT+ PER ICC ESR-3889 DRILLED-IN EXPANSION ANCHORS INTO CONCRETE 1. HILTI KWIK-BOLT TZ EXPANSION ANCHOR PER ICC ESR-1917 2. SIMPSON STRONG BOLT 2 WEDGE ANCHOR PER ICC ESR-3037 3. DEWALT POWER-STUD+ SD1 MECHANICAL ANCHOR PER ICC ESR-2818 ADHESIVE ANCHORS AND REBAR DOWELING INTO CONCRETE 1. HILTI HIT-HY 200 ADHESIVE ANCHOR SYSTEM PER ICC ESR-3187 2. SIMPSON SET-XP ADHESIVE ANCHOR SYSTEM PER ICC ESR-2508 3. DEWALT PE1000+ ADHESIVE ANCHOR SYSTEM PER ICC ESR-2583 DRILLED-IN SCREW ANCHORS INTO SOLID-GROUTED MASONRY 1. HILTI KWIK HUS-EZ SCREW ANCHORS PER ICC ESR-3056 2. SIMPSON TITEN HD SCREW ANCHOR PER ICC ESR-2713 3. DEWALT SCREW-BOLT+ PER ICC ESR-4042 DRILLED-IN EXPANSION ANCHORS INTO SOLID-GROUTED MASONRY 1. HILTI KWIK-BOLT 3 EXPANSION ANCHOR PER ICC ESR-1385 2. SIMPSON STRONG BOLT 2 WEDGE ANCHOR PER UES ER-240 3. DEWALT POWER-STUD+ SD1 MECHANICAL ANCHOR PER ICC ESR-2966 ADHESIVE ANCHORS AND REBAR DOWELING INTO SOLID-GROUTED MASONRY 1. HILTI HIT-HY 270 ADHESIVE ANCHOR SYSTEM PER ICC ESR-4143 2. SIMPSON SET-XP ADHESIVE ANCHOR SYSTEM PER IAPMO UES ER-265 3. DEWALT AC100+GOLD ADHESIVE ANCHOR SYSTEM PER ICC ESR-3200 4. STEEL ANCHOR ELEMENT MUST BE ASTM F1554 GRADE 55 THREADED ROD OR STEEL REINFORCEMENT PER DRAWINGS DEFERRED SUBMITTALS 1. DEFERRED COMPONENT SUBMITTALS ARE INTENDED TO BE VENDOR DESIGNED AND HAVE NOT BEEN DESIGNED BY THE ARCHITECT/ENGINEER OF RECORD. THE COMPONENT DESIGNER IS RESPONSIBLE FOR CODE CONFORMANCE AND NECESSARY CONNECTIONS NOT CALLED OUT ON ARCHITECTURAL OR STRUCTURAL DRAWINGS. 2. DEFERRED SUBMITTALS INCLUDING CALCULATIONS MUST BE STAMPED AND SIGNED BY A REGISTERED PROFESSIONAL ENGINEER. DEFERRED SUBMITTALS MUST FIRST BE SUBMITTED TO THE ENGINEER OF RECORD FOR A CURSORY REVIEW FOR LOADS IMPOSED ON THE BASIC STRUCTURE. 3. A SUBMITTAL MAY THEN BE MADE BY THE CONTRACTOR TO THE CONTRACTING OFFICER’S REPRESENTATIVE TO SUBMIT TO THE AUTHORITY HAVING JURISDICTION FOR REVIEW AND APPROVAL. 4. THE LIST OF ITEMS FOR DEFERRED SUBMITTALS INCLUDES THE FOLLOWING ITEMS: A. PRECAST CONCRETE MEMBERS B. METAL STAIR SYSTEMS C. PRECAST STAIR TREADS D. STAIR COMPONENTS NOT SHOWN ON DRAWINGS E. EXTERIOR CANOPY FRAMING 5. SUBMITTAL MUST INCLUDE: A. CALCULATIONS B. A DIAGRAM SHOWING LOAD MAGNITUDES AND LOCATIONS, SEPARATED INTO DEAD, LIVE, WIND AND/OR SEISMIC COMPONENTS - THAT ARE APPLIED TO THE PRIMARY STRUCTURE. STRUCTURAL SPECIAL INSPECTION & TESTING 1. SPECIAL INSPECTION AND TESTING MUST CONFORM TO CHAPTER 17 OF THE IBC. 2. SPECIAL INSPECTIONS AND TESTING MUST BE PERFORMED BY A QUALIFIED INSPECTION AND TESTING AGENCY. C-1 INDICATES STEEL COLUMN PER SCHEDULE C-24-1 INDICATES CONCRETE COLUMN PER SCHEDULE ON SHEET 405-SZD503 MC-1 INDICATES MOMENT FRAME COLUMN PER SCHEDULE ON SHEET 405-SZD504 GB-1 INDICATES GRADE BEAM PER SCHEDULE ON SHEET 405-SZD502 G-1 INDICATES GIRDERS PER DETAILS ON SHEET 405-SZD505 B-1 INDICATES BEAMS PER DETAILS ON SHEET 405-SZD505 MB-1 INDICATES MOMENT FRAME BEAM PER SCHEDULE ON SHEET 405-SZD506 S-1 INDICATES SLAB PER SCHEDULE ON SHEET 405-SZD505 INDICATES FOOTING MARK PER SCHEDULE INDICATES STEP FOOTING PER DETAIL INDICATES STEP IN SLAB INDICATES SLOPE IN SLAB INDICATES SPOT ELEVATION INDICATES POUR STRIP CENTERLINE INDICATES CMU WALL PER SCHEDULE AND DETAILS ON SHEET 405-SZD509 INDICATES CONCRETE WALL PER DETAILS ON SHEET 405-SZD501 STRUCTURAL DRAWING LEGEND SSCL F3 STRUCTURAL DRAWING SYMBOLS SECTION OR ELEVATION CUT SECTION, DETAIL, OR ELEVATION CALLOUT DRAWING WHERE SECTION, DETAIL OR ELEVATION IS SHOWN OR CALLED FROM X XXX 0.5% SLOPE TITLE SCALE: X' = X'-XX" PLAN, SECTION, DETAIL, OR ELEVATIONX XXX X XXX P/T POST TENSIONED PAF POWDER ACTUATED FASTENERS PCF POUNDS PER CUBIC FOOT PEMB PRE-ENGINEERED METAL BUILDING PERP PERPENDICULAR PH PHASE PL PLATE PLWD PLYWOOD PNL PANEL PREFAB PREFABRICATED PROJ PROJECT PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH QTY QUANTITY R RADIUS REF REFERENCE REINF REINFORCE, REINFORCEMENT REQD REQUIRED REV REVISION RO ROUGH OPENING S SOUTH SC SLIP-CRITICAL SCHED SCHEDULE SECT SECTION SF SQUARE FOOT SHT SHEET SIM SIMILAR SOG SLAB ON GRADE SPA SPACE, SPACING SPEC SPECIFICATION SQ SQUARE SSL SHORT SLOTTED HOLE SSLP SHORT SLOTTED HOLE PARALLEL SSLT SHORT SLOTTED HOLE TRANSVERSE SST STAINLESS STEEL STD STANDARD STL STEEL STRUCT STRUCTURAL SUSP SUSPENDED SW SHEAR WALL SYMM SYMMETRICAL T&B TOP AND BOTTOM TEMP TEMPORARY THK THICK THRU THROUGH TOB TOP OF BEAM TOC TOP OF CONCRETE TOF TOP OF FOOTING TOM TOP OF MASONRY TOS TOP OF STEEL TOW TOP OF WALL TRANSV TRANSVERSE TYP TYPICAL UL UNDERWRITERS LABORATORIES UNO UNLESS NOTED OTHERWISE VERT VERTICAL VOL VOLUME W WEST W/ WITH W/O WITHOUT WD WOOD WP WORKING POINT WT WEIGHT WTS WELDED THREADED STUDS WWR WELDED WIRE REINFORCEMENT FD FLOOR DRAIN FDTN FOUNDATION FIN FINISH(ED) FIN FLR FINISHED FLOOR FLG FLANGE FLR FLOOR FOC FACE OF CONCRETE FOM FACE OF MASONRY FOS FACE OF STUD, FACE OF STEEL FRMG FRAMING FS FAR SIDE FT FOOT, FEET FTG FOOTING FV FIELD VERIFY GA GAGE GALV GALVANIZED HDG HOT-DIP GALVANIZED HORIZ HORIZONTAL HS HIGH STRENGTH HSA HEADED STUD ANCHOR HT HEIGHT ID INSIDE DIAMETER IJ ISOLATION JOINT IN INCH INFO INFORMATION INT INTERIOR JBE JOIST BEARING ELEVATION JT JOINT KSI KIPS PER SQUARE INCH LBS POUNDS LF LINEAR FEET LL LIVE LOAD LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LONG LONGINTUDINAL LSL LONG SLOTTED HOLE LSLP LONG SLOTTED HOLE PARALLEL LSLT LONG SLOTTED HOLE TRANSVERSE LT GA LIGHT GAGE MAX MAXIMUM MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MTL METAL # NUMBER N NORTH NA NOT APPLICABLE NIC NOT IN CONTRACT NOM NOMINAL NS NEAR SIDE NTS NOT TO SCALE OA OVERALL OC ON CENTER OD OUTSIDE DIAMETER OF OUTSIDE FACE OPNG OPENING OPP OPPOSITE OWJ OPEN WEB JOIST & AND @ AT ADDL ADDITIONAL ADJ ADJACENT AFF ABOVE FINISHED FLOOR ALT ALTERNATE ALUM ALUMINUM APPROX APPROXIMATE AR ANCHOR RODS ARCH ARCHITECT ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS ATFP ANTI-TERRORISM FORCE PROTECTION BAL BALANCE BD BOARD BLDG BUILDING BLKG BLOCKING BLW BELOW BM BEAM BOT BOTTOM BRG BEARING BTWN BETWEEN CFS COLD-FORMED STEEL CG CENTER OF GRAVITY CIP CAST IN PLACE CJ CONTROL JOINT CJ CONSTRUCTION JOINT CL CENTERLINE CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONN CONNECTION CONSTR CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR COORD COORDINATE CTR CENTER DBL DOUBLE DEMO DEMOLISH DET DETAIL DIA OR Ø DIAMETER DIAG DIAGONAL DIM DIMENSION DIST DISTANCE DL DEAD LOAD DWG DRAWING E EAST EA EACH EF EACH FACE EL ELEVATION ELEC ELECTRIC EMBED EMBEDMENT ENGR ENGINEER EQ EQUAL EQUIV EQUIVALENT EW EACH WAY EXIST EXISTING EXP EXPANSION EXT EXTERIOR 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTSPRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:20 PM405 51 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZN504 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL GENERAL NOTES SOUTH RENTON TRANSIT CENTER 1 1.6 2 3 4 5 6 7 8 9 10 11 12.4 13 A B C D 1 405-SZE502 1 405-SZE501 1 405-SZX502 1 405-SZX501 2 405-SZX501 2 405-SZE501 2 405-SZE502 2 405-SZX502 12' - 0"8' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"8' - 0"12' - 0"60' - 9"60' - 6"60' - 9"1' - 0"MC-1, TYP C24-1, TYPC30-1 C30-1 MC-2, TYP C30-1C30-1 MC-2, TYP C30-1C30-1C24-1, TYPC30-1C30-1 MC-1, TYP 6 405-SZD502 12" CONC WALL 12" CONC WALL 5 405-SZD502 36" DIA x 70'-0" DRILLED SHAFT, TYP 24"x30" DEEP GRADE BEAM, TYP 12" CONC WALL 12" CONC WALL 30" DEEP PILE CAP, TYP 12" CONC WALL GB-1 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-1 GB-1GB-2GB-2GB-2GB-2GB-2GB-2GB-2GB-1GB-1 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-1GB-3GB-3GB-3GB-3GB-3GB-3GB-3GB-2GB-2GB-3GB-3GB-3GB-3GB-3GB-3GB-3GB-3GB-3GB-3GB-3GB-3GB-2GB-1GB-1GB-2GB-1GB-1C18 C18 GB-1GB-2GB-2GB-2GB-2GB-2GB-2GB-2GB-1GB-3GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-2 GB-1 GB-2GB-2 GB-1 GB-1 GB-1 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERN NOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:10 PM405 52 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SFP501 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL FOUNDATION PLAN SOUTH RENTON TRANSIT CENTER SCALE: 1/16" = 1'-0" FOUNDATION PLAN 1 1 1.6 2 3 4 5 6 7 8 9 10 11 12.4 13 A B C D 1 405-SZE502 1 405-SZE501 1 405-SZX502 1 405-SZX501 2 405-SZX501 5.1% 4.5% 2 405-SZE501 2 405-SZE502 2 405-SZX502 12' - 0"8' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"8' - 0"12' - 0" 1' - 0"1' - 0"60' - 9"60' - 6"60' - 9"1' - 0"0' - 0" -0' - 2" -1' - 0" -1' - 0" 0' - 0" 0' - 0" 0' - 8" 0' - 8" 5" SLAB-ON-GRADE, TYP CONC WALL 8" CMU WALL 6" CONC BARRIER WALL 0' - 0" 0' - 0" 0' - 0" -0' - 4" -0' - 4"-0' - 4" 5' - 9" 5' - 9"5' - 9" 5' - 9" 5" SLAB-ON-GRADE, TYP -2' - 0" -2' - 0"-2' - 0" -0' - 4"-0' - 4" -1' - 1" -0' - 4"-0' - 4" -2' - 6" 6" CONC BARRIER WALL, TYP 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERN NOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:11 PM1/16" = 1'-0" 405 53 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SGP501 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL SLAB PLAN - LEVEL 1 AND 1.5 SOUTH RENTON TRANSIT CENTER SCALE: 1/16" = 1'-0" SLAB PLAN - LEVEL 1 AND 1.5 1 1 1.6 2 3 4 5 6 7 8 9 10 11 12.4 13 A B C D 1 405-SZE502 1 405-SZE501 1 405-SZX502 1 405-SZX501 2 405-SZX501 4.2% 4.2% 4.2% 2 405-SZE501 2 405-SZE502 2 405-SZX502 12' - 0"8' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"8' - 0"12' - 0" 1' - 0"1' - 0"60' - 9"60' - 6"60' - 9"1' - 0"24"W x 40"D UPTURNED MOMENT FRAME BEAM 30"W x 36"D P/T GIRDER 30"W x 36"D P/T GIRDER 24"W x 42"D UPTURNED MOMENT FRAME BEAM 7" P/T SLAB, TYP 18"W x37"D P/T BEAM, TYP UNO 24"W x 40"D UPTURNED MOMENT FRAME BEAM 24"W x 40"D UPTURNED MOMENT FRAME BEAM184' - 0". 8" GAP BETWEEN RAMPS, TYP 4 405-SZD508 5 405-SZD508 5 405-SZD508 1 405-SZD508 TYP 3 405-SZD506 2 405-SZD506 MB-2 MB-1 MB-1 MB-1 MB-1 MB-1 MB-1 MB-2 B2 MB-3MB-4MB-4MB-4MB-4MB-4MB-3MB-1MB-2 MB-1 MB-1 MB-1 MB-1 MB-1 MB-1 MB-2MB-3MB-4MB-4MB-4MB-4MB-4MB-3B2 B1B1B1. 8" GAP BETWEEN RAMPS, TYP 5 405-SZD508 MB-1 B2B2 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERN NOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:11 PM1/16" = 1'-0" 405 54 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SGP502 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL FRAMING PLAN - LEVEL 2 AND 2.5 SOUTH RENTON TRANSIT CENTER SCALE: 1/16" = 1'-0" FRAMING PLAN - LEVEL 2 AND 2.5 1 FRAMING PLAN NOTES: 1. UNLESS NOTED OTHERWISE POST TENSION SLAB MUST BE 7" THICK. 2. REFER TO SHEETS 405-SZD507 AND 405-SZD508 FOR TYPICAL POST TENSION DETAILS. 1 1.6 2 3 4 5 6 7 8 9 10 11 12.4 13 A B C D 1 405-SZE502 1 405-SZE501 1 405-SZX502 1 405-SZX501 2 405-SZX501 4.2% 4.2% 4.2% 2 405-SZE501 2 405-SZE502 2 405-SZX502 12' - 0"8' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"8' - 0"12' - 0" 1' - 0"1' - 0"60' - 9"60' - 6"60' - 9"1' - 0"184' - 0"4 405-SZD508 5 405-SZD508 1 405-SZD508 TYP MB-2 MB-1 MB-1 MB-1 MB-1 MB-1 MB-1 MB-2 B2 MB-3MB-4MB-4MB-4MB-4MB-4MB-3MB-1MB-2 MB-1 MB-1 MB-1 MB-1 MB-1 MB-1 MB-2MB-3MB-4MB-4MB-4MB-4MB-4MB-3B2 B2B2 B2B2 . 8" GAP BETWEEN RAMPS, TYP 5 405-SZD508 MB-1 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERN NOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:11 PM1/16" = 1'-0" 405 55 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SGP503 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL FRAMING PLAN - LEVEL 3 AND 3.5 SOUTH RENTON TRANSIT CENTER SCALE: 1/16" = 1'-0" FRAMING PLAN - LEVEL 3 AND 3.5 1 FRAMING PLAN NOTES: 1. UNLESS NOTED OTHERWISE POST TENSION SLAB MUST BE 7" THICK. 2. REFER TO SHEETS 405-SZD507 AND 405-SZD508 FOR TYPICAL POST TENSION DETAILS. 1 1.6 2 3 4 5 6 7 8 9 10 11 12.4 13 A B C D 1 405-SZE502 1 405-SZE501 1 405-SZX502 1 405-SZX501 2 405-SZX501 4.2% 4.2% 4.2% 2 405-SZE501 2 405-SZE502 2 405-SZX502 12' - 0"8' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"8' - 0"12' - 0" 1' - 0"1' - 0"60' - 9"60' - 6"60' - 9"1' - 0"184' - 0"4 405-SZD508 5 405-SZD508 1 405-SZD508 TYP MB-2 MB-1 MB-1 MB-1 MB-1 MB-1 MB-1 MB-2 B2 MB-3MB-4MB-4MB-4MB-4MB-4MB-3MB-1MB-2 MB-1 MB-1 MB-1 MB-1 MB-1 MB-1 MB-2MB-3MB-4MB-4MB-4MB-4MB-4MB-3B2 B2B2 B2B2 . 8" GAP BETWEEN RAMPS, TYP 5 405-SZD508 MB-1 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERN NOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:11 PM1/16" = 1'-0" 405 56 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SGP504 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL FRAMING PLAN - LEVEL 4 AND 4.5 SOUTH RENTON TRANSIT CENTER SCALE: 1/16" = 1'-0" FRAMING PLAN - LEVEL 4 AND 4.5 1 FRAMING PLAN NOTES: 1. UNLESS NOTED OTHERWISE POST TENSION SLAB MUST BE 7" THICK. 2. REFER TO SHEETS 405-SZD507 AND 405-SZD508 FOR TYPICAL POST TENSION DETAILS. 1 1.6 2 3 4 5 6 7 8 9 10 11 12.4 13 A B C D 1 405-SZE502 1 405-SZE501 1 405-SZX502 1 405-SZX501 2 405-SZX501 4.2% 4.2% 2 405-SZE501 2 405-SZE502 2 405-SZX502 12' - 0"8' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"8' - 0"12' - 0" 1' - 0"1' - 0"60' - 9"60' - 6"60' - 9"1' - 0"184' - 0"4 405-SZD508 6 405-SZD508 1 405-SZD508 TYP 4 405-SZD508 MB-2 MB-1 MB-1 MB-1 MB-1 MB-1 MB-1 MB-2 B2 MB-3MB-4MB-4MB-4MB-4MB-4MB-3MB-1MB-2 MB-1 MB-1 MB-1 MB-1 MB-1 MB-1 MB-2MB-3MB-4MB-4MB-4MB-4MB-4MB-3B2 B2B2 B2B2 5 405-SZD508 MB-1 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERN NOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:11 PM1/16" = 1'-0" 405 57 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SGP505 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL FRAMING PLAN - LEVEL 5 AND 5.5 SOUTH RENTON TRANSIT CENTER SCALE: 1/16" = 1'-0" FRAMING PLAN - LEVEL 5 AND 5.5 1 FRAMING PLAN NOTES: 1. UNLESS NOTED OTHERWISE POST TENSION SLAB MUST BE 7" THICK. 2. REFER TO SHEETS 405-SZD507 AND 405-SZD508 FOR TYPICAL POST TENSION DETAILS. L01-TOS 0' -0" L01-TOS 0' -0" L02-TOS 11' -6" L03-TOS 22' -0" 1 1.6 2 3 4 5 6 7 8 9 10 11 12.4 13 L04-TOS 32' -6" L05-TOS 43' -0" L05.5-TOS 48' -3" L01.5-TOS 5' -9" L03.5-TOS 27' -3" L02.5-TOS 16' -9" L04.5-TOS 37' -9" T/PARA 51' -9" 1 405-SZX502 2 405-SZX502 20' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"20' - 0" 7 405-SZD508 L01-TOS 0' -0" L01-TOS 0' -0" L02-TOS 11' -6" L03-TOS 22' -0" 1 1.6 234567891011 12.4 13 L04-TOS 32' -6" L05-TOS 43' -0" L05.5-TOS 48' -3" L01.5-TOS 5' -9" L03.5-TOS 27' -3" L02.5-TOS 16' -9" L04.5-TOS 37' -9" T/PARA 51' -9" 1 405-SZX502 2 405-SZX502 20' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"20' - 0" 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:18 PM1/16" = 1'-0" 405 58 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZE501 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL ELEVATIONS SOUTH RENTON TRANSIT CENTER SCALE: 1/16" = 1'-0"405-SFP501 ELEVATION - SOUTH 1 SCALE: 1/16" = 1'-0"405-SFP501 ELEVATION - NORTH 2 L01-TOS 0' -0" A B C D L05.5-TOS 48' -3" L01.5-TOS 5' -9" L03.5-TOS 27' -3" L02.5-TOS 16' -9" L04.5-TOS 37' -9" T/PARA 51' -9" 1 405-SZX501 2 405-SZX501 60' - 9"60' - 6"60' - 9" L01-TOS 0' -0" L02-TOS 11' -6" L03-TOS 22' -0" ABCD L04-TOS 32' -6" L05-TOS 43' -0" 1 405-SZX501 2 405-SZX501 60' - 9"60' - 6"60' - 9" 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:19 PM1/16" = 1'-0" 405 59 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZE502 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL ELEVATIONS SOUTH RENTON TRANSIT CENTER SCALE: 1/16" = 1'-0"405-SFP501 ELEVATION - WEST 1 SCALE: 1/16" = 1'-0"405-SFP501 ELEVATION - EAST 2 L01-TOS 0' -0" L02-TOS 11' -6" L03-TOS 22' -0" 1 1.6 2 3 4 5 6 7 8 9 10 11 12.4 13 L04-TOS 32' -6" L05-TOS 43' -0" L05.5-TOS 48' -3" L01.5-TOS 5' -9" L03.5-TOS 27' -3" L02.5-TOS 16' -9" L04.5-TOS 37' -9" T/PARA 51' -9" 1 405-SZX502 12" CONC WALL 16" x 18" CONC BEAM 2 405-SZX502 20' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"20' - 0" L01-TOS 0' -0" L02-TOS 11' -6" L03-TOS 22' -0" 1 1.6 2 3 4 5 6 7 8 9 10 11 12.4 13 L04-TOS 32' -6" L05-TOS 43' -0" L05.5-TOS 48' -3" L01.5-TOS 5' -9" L03.5-TOS 27' -3" L02.5-TOS 16' -9" L04.5-TOS 37' -9" T/PARA 51' -9" 1 405-SZX502 2 405-SZX502 20' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"20' - 0" 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:21 PM1/16" = 1'-0" 405 60 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZX501 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL SECTIONS SOUTH RENTON TRANSIT CENTER SCALE: 1/16" = 1'-0" SECTION BETWEEN GRIDS B AND C 1 SCALE: 1/16" = 1'-0"405-SFP501 SECTION BETWEEN GRIDS C AND D 2 L01-TOS 0' -0" L02-TOS 11' -6" L03-TOS 22' -0" A B C D L04-TOS 32' -6" L05-TOS 43' -0" L05.5-TOS 48' -3" L01.5-TOS 5' -9" L03.5-TOS 27' -3" L02.5-TOS 16' -9" L04.5-TOS 37' -9" T/PARA 51' -9" 1 405-SZX501 2 405-SZX501 60' - 9"60' - 6"60' - 9" L01-TOS 0' -0" L02-TOS 11' -6" L03-TOS 22' -0" A B C D L04-TOS 32' -6" L05-TOS 43' -0" L05.5-TOS 48' -3" L01.5-TOS 5' -9" L03.5-TOS 27' -3" L02.5-TOS 16' -9" L04.5-TOS 37' -9" T/PARA 51' -9" 1 405-SZX501 2 405-SZX501 60' - 9"60' - 6"60' - 9" 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:22 PM1/16" = 1'-0" 405 61 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZX502 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL SECTIONS SOUTH RENTON TRANSIT CENTER SCALE: 1/16" = 1'-0"405-SFP501 SECTION BETWEEN GRIDS 7 AND 8 1 SCALE: 1/16" = 1'-0"405-SFP501 SECTION BETWEEN GRIDS 4 AND 5 2 NOTES: 1. SEE GENERAL NOTES FOR CONCRETE COVER REQUIREMENTS & BAR CLEARANCES. 2. CORNER BARS ARE THE SAME SIZE AND SPACING AS HORIZONTAL REINFORCEMENT. 3. REINFORCEMENT AT ALL CONCRETE WALL CORNERS, INTERSECTIONS AND ENDS TO BE FABRICATED AND PLACED IN ACCORDANCE WITH APPROPRIATE DETAIL SHOWN. 4. DETAIL ALSO APPLIES TO ALL CONTINUOUS WALL FOOTINGS. 5. SINGLE CURTAIN REINFORCEMENT SHALL BE PLACED AT WALL CENTERLINE UNLESS NOTED OTHERWISE. 6. VERTICAL REINFORCEMENT SHOWN IS ADDITIONAL IF TYPICAL VERTICAL REINFORCEMENT IS NOT IN PROPER LOCATION. 7. 90° STANDARD HOOK MAY BE SUBSTITUTED FOR CORNER BARS. USE 90° STANDARD HOOK FOR EMBEDMENT LESS THAN 24" PAST FACE OF WALL. CORNER BAR TO MATCH TYP HORIZ REINF (4) ADDL VERT BARS ADDL VERT BARS SEE NOTE 6, TYP TYP WALL REINF .PER SCHEDLbEND BAR SIZE AND SPACING TO MATCH HORIZ WALL REINF 3/4" CHAMFER, TYP PER SCHED Lb PER SCHED Lb ALTERNATE CORNER BAR AS SHOWN PER SCHED Lb (2) VERT, TYP CONC WALL PER PLAN TYP WALL REINF . NOTE: OBTAIN APPROVAL OF ENGINEER FOR LOCATION OF CONSTRUCTION JOINTS. .TYP WALL REINF Lb 1 1/2" DEEP x 1/3 WALL WIDTH KEY WAY Lb EITHER SIDE2 1/2" MINEITHER SIDE2 1/2" MINCONC WALL PER PLAN #4 SPACED AS TYP HORIZ REINF JOINT W/ FILLER & SEALANT (2) VERT BARS, TYP TYP WALL REINF . NOTE: PROVIDE EXPANSION JOINT AT X'-X" MAXIMUM. JOINT W/ FILLER & SEALANT .TYP WALL REINF CONC WALL PER PLAN 24"24"AS REQD CONC WALL PER PLAN JOINT W/ FILLER & SEALANT (2) VERT BARS, TYP .TYP WALL REINF PVC WATERSTOP JOINT W/ FILLER & SEALANT PVC WATERSTOP .TYP WALL REINF CONC WALL PER PLAN NOTE: PROVIDE EXPANSION JOINT AT X'-X" MAXIMUM. ABBREVIATIONS db = BAR DIAMETER Ld = TENSION DEVELOPMENT LENGTH Ldt = TENSION DEVELOPMENT LENGTH FOR A TOP BAR Lb = CLASS B LAP SPLICE LENGTH, 1.3Ld Lbt = CLASS B LAP SPLICE LENGTH FOR A TOP BAR, 1.3 Ldt Ldh = TENSION DEVELOPMENT LENGTH FOR A STANDARD HOOK f'c = CONCRETE COMPRESSIBLE STRENGTH AT 28 DAYS fy = BAR YIELD STRENGTH NOTES: 1. USE THE LENGTH IN THESE SCHEDULES, UNLESS NOTED OTHERWISE. 2. USE LENGTH IN () WHEN BAR COVER IS db OR LESS OR BAR CLEAR SPACING IS 2db OR LESS. 3. TOP BAR IS HORIZONTAL BAR WITH MORE THAN 12" OF FRESH CONCRETE CAST BELOW IT. SIZE Ld Ldt Lb Lbt Ldh #4 #5 #6 #7 #8 #9 #10 #11 24 30 36 (53) 52 (78) 59 (89) 67 (100) 75 (113) 84 (125) 31 39 46 (69) 67 (101) 77 (116) 87 (130) 98 (147) 109 (163) 46 (69) 67 (101) 77 (116) 87 (130) 98 (147) 40 50 60 (90) 88 (132) 100 (150) 113 (170) 127 (191) 141 (212) 15 18 21 24 27 30 33 SIZE Ld Ldt Lb Lbt Ldh #4 #5 #6 #7 #8 #9 #10 #11 21 27 32 (48) 13 16 19 21 24 27 30 f'c = 4,000 psi fy = 75,000 psi f'c = 5,000 psi fy = 75,000 psi SIZE Ld Ldt Lb Lbt Ldh #4 #5 #6 #7 #8 #9 #10 #11 19 24 29 (44) 42 (64) 48 (73) 55 (82) 61 (92) 68 (102) 25 31 38 (57) 55 (83) 63 (94) 71 (106) 80 (120) 89 (133) 25 31 38 (57) 55 (83) 63 (94) 71 (106) 80 (120) 89 (133) 33 41 49 (74) 72 (107) 82 (123) 92 (138) 104 (156) 115 (173) 12 15 17 19 22 25 27 f'c = 6,000 psi fy = 75,000 psi 46 (70) 53 (80) 60 (90) 67 (101) 75 (112) 97 (146) 88 (131) 78 (117) 69 (103) 60 (90) 41 (62) 41 (62) 60 (90) 69 (103) 78 (117) 88 (131) 97 (146) 28 34 28 34 36 45 SIZE Ld Ldt Lb Lbt Ldh #4 #5 #6 #7 #8 #9 #10 #11 19 24 28 (43) 42 (62) 47 (71) 54 (80) 60 (90) 67 (100) 25 31 37 (55) 54 (81) 62 (92) 70 (104) 78 (117) 87 (130) 25 31 37 (55) 54 (81) 62 (92) 70 (104) 78 (117) 87 (130) 32 40 48 (72) 70 (105) 80 (120) 90 (136) 102 (153) 113 (170) 9 12 14 17 19 21 24 27 SIZE Ld Ldt Lb Lbt Ldh #4 #5 #6 #7 #8 #9 #10 #11 17 21 25 (38) 8 11 13 15 17 19 22 24 f'c = 4,000 psi fy = 60,000 psi f'c = 5,000 psi fy = 60,000 psi SIZE Ld Ldt Lb Lbt Ldh #4 #5 #6 #7 #8 #9 #10 #11 15 19 23 (35) 34 (51) 39 (58) 44 (66) 49 (74) 55 (82) 20 25 30 (45) 44 (66) 50 (76) 57 (85) 64 (96) 71 (106) 20 25 30 (45) 44 (66) 50 (76) 57 (85) 64 (96) 71 (106) 26 33 39 (59) 57 (86) 65 (98) 74 (111) 83 (125) 92 (138) 8 10 12 14 15 17 20 22 f'c = 6,000 psi fy = 60,000 psi 37 (56) 42 (64) 48 (72) 54 (81) 60 (90) 78 (117) 70 (105) 62 (93) 55 (83) 48 (72) 33 (50) 33 (50) 48 (72) 55 (83) 62 (93) 70 (105) 78 (117) 22 28 22 28 29 36 43 (65) 63 (94) 72 (108) 81 (121) 91 (137) 101 (152) 54 (81) 78 (118) 90 (134) 101 (152) 114 (171) 126 (190) 31 39 109 (163) 12 11 10 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:13 PM405 62 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZD501 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL TYPICAL CONCRETE DETAILS SOUTH RENTON TRANSIT CENTER SCALE: 3/4" = 1'-0" TYP HORIZ REINF FOR CONC WALLS & STEM WALLS 1 SCALE: 1" = 1'-0" WALL CONSTRUCTION JOINTS 3 SCALE: 1" = 1'-0" WALL EXPANSION JOINT - INTERIOR 4 SCALE: 1" = 1'-0" WALL EXPANSION JOINT - EXTERIOR 5 SCALE: 1/2" = 1'-0" DEVELOPMENT& LAP SPLICE LENGTH SCHED - CONCRETE 2 TOP LEFT CONT MIN 6"CLEAR SPAN L1 ACI STD HOOK (MIN OF 2 BARS EXT INTO SUPPORT) STIRRUPS PER SCHED BOT BARS PIERCL TOP RIGHT OVER SUPPORT CLEAR SPAN L2 PIERCL TOP RIGHT OVER SUPPORT BOT CONT TOP RIGHT CONT BOT BARS 0.25 L1 TOP LEFT OVER SUPPORT TOP RIGHT CONT TYP 2"0.125 L2 WHICHEVER IS GREATER 0.3 L1 OR L2 WHICHEVER IS GREATER 0.3 L1 OR L2 0.3 L2 0.3 L2 0.125 L2 L3 CANTILEVER TOC EL PER PLAN TYP CONST JT 2x6 SHEAR KEY LOCATED IN MIDDLE THIRD OF SPAN, WHERE REQD (2) #5x4'-0" EF CTR ON CONST JT 0.125 L1 6"6" 6"6" BEAM MARK RIGHT END WIDTH B HEIGHT H TOP LEFT CONTINUOUS TOP LEFT OVER SUPPORT OR TOP END GB-1 GB-2 24" 30" GB-3 18" 30" BOTTOM CENTER BOTTOM CONTINUOUS SIZE BEAM STIRRUPS COMMENTSTOP RIGHT OVER SUPPORT OR TOP END TOP RIGHT CONTINUOUS SHAPE SPACING (3) #9 #4 @ 7" OC #4 @ 9" OC (2) #9 (2) #9 #4 17 @ 8" OC BALANCE @ 18" (2) #924" 30"(3) #9 NOTE: PROVIDE #4 @ 10" OC FACE BAR. FACE BAR AT EA FACE SPACING 10" (2) #9 (2) #9 (2) #9 (2) #9 (2) #9 (2) #9 (2) #9 (3) #9 (2) #9 (3) #9 (2) #9 (2) #9 (2) #9 (2) #5 (2) #5 (2) #5 10" 10" BOT REINF PER SCHED TOC EL PER PLAN HB STIRRUPS PER SCHED FACE BARS PER SCHED TOP REINF PER SCHED BOT REINF PER SCHED TOC EL PER PLAN B STIRRUPS PER SCHED FACE BARS PER SCHED TOP REINF PER SCHED HSOG PER PLAN TOC EL PER PLAN L4x4x1/4x DOOR OPNG W/ 3/4"øx6" HSA @ 18" OC PVC WATERSTOP W/ WELDED JOINTS #5 @ 12" OC EW T&B #5 @ 12" OC CENTERED IN WALL REBAR TO MATCH SIZE & SPACING OF SLAB REINF #5 @ 12" OC , TYP NOTES: 1. VERIFY ELATOR PIT SIZE AND DEPTH WITH ARCHITECTURAL DRAWINGS. 2. VERIFY DIMENSIONS AND LOCATION WITH ELEVATOR SUPPLIER PRIOR TO CONSTRUCTION. . #5 EA SIDE OF BLOCKOUT EXTEND 24" PAST BLOCKOUT EDGES EA DIRECTION SEE NOTE 2 BLOCKOUT FOR SHAFT TOC EL PER PLAN 1'-0"12"AS REQD . SUMP PIT. SEE NOTE 1 GALV L4x3x1/4 LLV W/ 1/2"ø EXP ANCHORS @ 12" OC (3 1/2" MIN EMBED DEPTH) (3) #5 @ 12" OC #5 GALV GRATING #5 @ 12" OC CENTERED IN WALL NOTES: 1. VERIFY SUMP PIT DIMENSIONS AND LOCATION WITH ELEVATOR SUPPLIER PRIOR TO CONSTRUCTION. 2. FOR INFORMATION NOT SHOWN SEE TYPICAL ELEVATOR PIT SECTION. ELEVATOR PIT WALL TOC EL PER PLAN 8"8"24"24"12"AS REQD WATERSTOP 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:14 PM405 63 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZD502 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL TYPICAL CONCRETE DETAILS SOUTH RENTON TRANSIT CENTER SCALE: 1/2" = 1'-0" TYPICAL GRADE BEAM REINFORCING DETAIL 1 SCALE: 1" = 1'-0" CONCRETE GRADE BEAM REINFORCEMENT SCHEDULE 2 SCALE: 3/4" = 1'-0" TYP GRADE BEAM REINF 3 SCALE: 3/4" = 1'-0" TYP GRADE BM REIN 4 SCALE: 1" = 1'-0"405-SFP501 ELEVATOR PIT SECTION 6SCALE: 1" = 1'-0"405-SFP501 SUMP AT ELEVATOR PIT 5 SOG PER PLAN DOWELS TO MATCH VERT REINF VERT REINF PER SCHED3"ZONE AZONE BZONE AZONE AZONE B3"TIE REINF PER SCHED3"TIE REINF PER SCHED3'-0"ZONE ABEAM WHERE OCCURS LdcSLAB BLOCKOUT @ COLUMN TOC EL PER PLAN TOF EL PER PLAN TOC EL PER PLAN TOC EL PER PLAN LdcGRID GRID COL TIES PER SCHED 3/4" CHAMFER, TYPL BGRID GRID COL TIES PER SCHED COL TIES PER SCHED 3/4" CHAMFER, TYP BL COLUMN MARK COLUMN SIZE LxB C24-1 24" x 24" LEVEL 5 & 5.5 LEVEL 4 & 4.5 LEVEL 3 & 3.5 LEVEL 2 & 2.5 LEVEL 1 & 1.5 (8) #10 (DET 2 & 3) #5 @ 4.5" OC #5 @ 6" OC (8) #10 (DET 2 & 3) #5 @ 4.5" OC #5 @ 6" OC (12) #10 (DET 2 & 3) #5 @ 4.5" OC #5 @ 6" OC (12) #10 (DET 2 & 3) #5 @ 4.5" OC #5 @ 6" OC C18 18" x 18" (4) #6 (DET 3) #4 @ 6" OC #4 @ 6" OC VERT ZONE A ZONE B VERT ZONE A ZONE B VERT ZONE A ZONE B VERT ZONE A ZONE B NOTE: SEE DETAILS FOR COLUMN REINFORCEMENT LAYOUT. 2 405-SZD503 3 405-SZD503 4 405-SZD503 C30-1 30" x 30" (12) #10 (DET 2 & 3) #5 @ 5" OC #5 @ 6" OC (12) #10 (DET 2 & 3) #5 @ 5" OC #5 @ 6" OC (12) #10 (DET 2 & 3) #5 @ 5" OC #5 @ 6" OC (12) #10 (DET 2 & 3) #5 @ 5" OC #5 @ 6" OC GRID GRID COL TIES PER SCHED COL TIES PER SCHED 3/4" CHAMFER, TYP SLEEVES IN COL AS REQD FOR CABLE BARRIERS. SEE ARCH FOR LOCATION & SIZE LB SCALE: 3/8" = 1'-0" TYP COLUMN REINFORCEMENT DETAIL 6 SCALE: 1" = 1'-0"405-SZD503 COLUMN REINFORCEMENT DETAIL 2 SCALE: 1" = 1'-0"405-SZD503 COLUMN REINFORCEMENT DETAIL 4 SCALE: 1" = 1'-0" GRAVITY COLUMN SCHEDULE 1 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:14 PM405 64 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZD503 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL TYPICAL CONCRETE DETAILS SOUTH RENTON TRANSIT CENTER SCALE: 1" = 1'-0"405-SZD503 COLUMN REINF WITH SLEEVE DETAIL 3 SOG PER PLAN DOWELS TO MATCH VERT REINF VERT REINF PER SCHED MAX 4" TIE REINF SPACING @ SPLICE EXTEND TIES INTO FTGLdcCOL PER PLAN & SCHED MOMENT FRAME BEAM REINF PER SCHED MOMENT FRAME BEAM PER SCHED TOC EL PER PLAN COL TIE REINF PER DETAILS CL OF COL SPLICE REBAR TERMINATOR IN LIEU OF HOOKS SLAB BLOCKOUT @ COLUMN TOC EL PER PLAN TOC EL PER PLAN TOF EL PER PLAN X'-X"COLUMN MARK COLUMN SIZE LxB MC-2 24" x 42" MC-1 24" x 42" (20) #9 (SEE DET 2) (20) -#9 (SEE DET 2) (20) #9 (SEE DET 2) LEVEL 5 & 5.5 LEVEL 4 & 4.5 LEVEL 2 & 2.5 LEVEL 1 & 1.5 LEVEL 3 & 3.5 (12) #9 (SEE DET 3) (12) #9 (SEE DET 3) (12) #9 (SEE DET 3) VERT REINF TIE REINF NOTES VERT REINF TIE REINF NOTES VERT REINF TIE REINF NOTES VERT REINF TIE REINF NOTES VERT REINF TIE REINF NOTES (20) #9 (SEE DET 2) (12) #9 (SEE DET 3) (20) #9 (SEE DET 2) (12) #9 (SEE DET 3) GRID GRID #5 @ 4" OC #5 @ 4" OC #5 @ 4" OC EQEQEQBL GRID GRID #5 @ 4" OC #5 @ 4" OC ALT HOOK DIRECTION & LOCATION, TYP POST TENSION (PT) BEAM WHERE OCCURS 3/4" CHAMFER, TYP BL SCALE: 3/8" = 1'-0" MOMENT FRAME COLUMN REINF DETAIL 4 SCALE: 1" = 1'-0" MOMENT FRAME COLUMN REINF SCHEDULE 1 SCALE: 1" = 1'-0" MC COLUMN REINFORCEMENT DETAIL 2 SCALE: 1" = 1'-0" MC COLUMN REINFORCEMENT DETAIL 3 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:15 PM405 65 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZD504 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL TYPICAL CONCRETE DETAILS SOUTH RENTON TRANSIT CENTER BOT REINF PER SCHED STIRRUPS PER SCHED TOP REINF PER SCHED FACE BAR PER SCHED SLAB REINF PER PLAN ADDL #4 x @ 10" OC SLAB WHERE OCCURS TOC EL PER PLAN HB 24"36" TOP REINF PER SCHED STIRRUPS PER SCHED BOT REINF PER SCHED FACE BAR PER SCHED, TYP SLAB REINF PER PLAN TOC EL PER PLAN HBSSS TOP RIGHT LONG L1 ACI STD HOOK BOT CONT SUPPORTCL 0.25 L1 (3) #4 0.3 L1 TOC EL PER PLAN S/2 S 0.15 L1 0.15 L1 0.3 L2 0.15 L2 0.25 L1 0.25 L2 L2 SLAB MARK RIGHT END HEIGHT H TOP LEFT S-1 SOUTH 8" #5 @ 12" OC NOTE: PROVIDE #4 @ 10" OC FACE BAR. BOT CTR #5 @ 12" OC BOT CONT #5 @ 12" OC TOP RIGHT LONG #5 @ 12" OC TOP RIGHT SHORT #5 @ 12" OC SHRINKAGE REINF SIZE S #4 12" TOP LEFT BOT CTR TOP RIGHT SHORT (7) #4 6"6" TOP LEFT CONT MIN 6"CLEAR SPAN L1 0.125 L1 TOP END BAR ACI STD HOOK (MIN OF 2 BARS EXT INTO SUPPORT) STIRRUPS PER SCHED BOT BARS BEAM OR COLCL TOP RIGHT OVER SUPPORT CLEAR SPAN L2 BEAM OR COLCL TOP RIGHT OVER SUPPORT BOT CONT TOP RIGHT CONT 6"6"BOT BARS 1.4 Ld 0.25 L1 TOP LEFT OVER SUPPORT TOP RIGHT CONT TYP 2" 0.125 L2 WHICHEVER IS GREATER 0.3 L1 OR L2 WHICHEVER ID GREATER 0.3 L1 OR L2 0.3 L2 0.3 L2 0.125 L2 L3 CANTILEVER TOC EL PER PLAN 6"6" BEAM MARK RIGHT END WIDTH B HEIGHT H TOP LEFT CONTINUOUS TOP LEFT OVER SUPPORT OR TOP END B1 B2 16" 18" BOTTOM CENTER BOTTOM CONTINUOUS SIZE BEAM STIRRUPS COMMENTSTOP RIGHT OVER SUPPORT OR TOP END TOP RIGHT CONTINUOUS SHAPE SPACING - #4 @ 7" OC #4 @ 9" OC(2) #514" 16" NOTE: PROVIDE #4 @ 10" OC FACE BAR. FACE BAR AT EA FACE SPACING (2) #6 (2) #5 (2) #6 (1) #6 (2) #6 (2) #5 (2) #6 (2) #5 (2) #6 (2) #5 SCALE: 3/4" = 1'-0" TYPICAL UPTURN BEAM REINF DETAIL 3 SCALE: 3/4" = 1'-0" TYP DOWNTURN BEAM REINF DETAIL 2 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:15 PM405 66 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZD505 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL TYPICAL CONCRETE DETAILS SOUTH RENTON TRANSIT CENTER SCALE: 1/2" = 1'-0" TYPICAL ONE-WAY SLAB REINFORCING DETAIL 5 SCALE: 1/2" = 1'-0" TYPICAL CONCRETE BEAM REINFORCING DETAIL 4 SCALE: 1" = 1'-0" CONCRETE BEAM REINFORCEMENT SCHEDULE 1 TOPLEVEL 5 & 5.5 LEVEL 4 & 4.5 LEVEL 3 & 3.5 LEVEL 2 & 2.5 INTERIOR SUPPORT BOTTOM MB-2 EXTERIOR SUPPORT MB-1 MB-3 TOP BOTTOM TOP BOTTOM TOP BOTTOM (5) #8 (5) #8 (5) #8 (5) #8 (5) #8 (5) #8 (6) #8 (5) #8 (5) #8 (5) #8 (6) #8 (5) #8 (5) #8 (5) #8 (6) #9 (5) #9 (6) #9 (6) #9 (4) #9(4) #9 (6) #9 (5) #9 TYPICAL BAR LAYOUT 4 BARS3 BARS 5 BARS 6 BARS 2" , TYP EQEQ 2" , TYP EQ EQ EQ 2" , TYP EQ EQ EQ EQ 2" , TYP EQ EQ EQ 3", TYPMB-4 TOP BOTTOM (5) #8 (5) #8 (5) #8 (5) #8 (4) #8 (4) #8 (5) #8 (5) #8 BEAM MARK BEAM SIZE BxH 24"x40"24"x40"24"x40"24"x40" (6) #8 (6) #8 (5) #8 (5) #8 (5) #8 (5) #8 (5) #8 (5) #8 #4 @ 12" OC x TYP, UNO BOT REINF PER SCHED FACE BARS PER SCHED #4 @ 8" OC STIRRUPS @ NON SPECIAL ZONE, SEE TOP REINF PER SCHED #4 @ 6" OC STIRRUPS @ SPECIAL TRANSVERSE ZONE ONLY B SLAB BOT REINF PER PLAN.H18"7'-0" 4 405-SZD506 #4 @ 12" OC x TYP, UNO TOP REINF PER SCHED FACE BARS PER SCHED #4 @ 8" OC STIRRUPS @ NON SPECIAL ZONE, SEE BOT REINF PER SCHED B SLAB BOT REINF PER PLAN SLAB @ SIM .H18"7'-0" 4 405-SZD506 TYP 2" NON SPECIAL ZONE STIRRPIS . SPECIAL TRANSVERSE ZONE STIRRUPS, TYP 2H (8'-0" MIN) PER . Lb STIRRUPS @ LAP SPLICE #5 @ 4" OC STIRRUPS @ SPECIAL TRANSVERSE ZONE PER DETAILS STIRRUPS OUTSIDE OF 2H ZONE COL TIE COL VERT REINF BEAM TOP REINF PER SCHED BEAM BOT REINF PER SCHED CL LAP SPLICE @ MIDSPAN FACE BAR PER DETAILSSPECIAL TRANSVERSE ZONE STIRRUPS, TYP 2H (8'-0" MIN)h2 405-SZD506 SCALE: 1" = 1'-0" MOMENT FRAME BEAM REINFORCEMENT SCHEDULE 1 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:16 PM405 67 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZD506 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL TYPICAL CONCRETE DETAILS SOUTH RENTON TRANSIT CENTER SCALE: 1" = 1'-0"405-SGP502 MF BEAM (UPTURN)2 SCALE: 1" = 1'-0"405-SGP502 MF BEAM (DOWNTURN)3 SCALE: 1/2" = 1'-0"405-SZD506 TYP MOMENT FRAME BEAM REINF AT INTERIOR SPANS 4 GRID GRID (2) #6 TOP(4) #10 TOP (2) #8 BOT (2) #8 BOT 15'-0" TYP PT PROFILE. SEE PLAN FOR PROFILE & QUANTITY 15'-0" 2"10 @ 6" O/C #4 STIRRUPS REMAINING @ 24" OC #4 STIRRUPS 10 @ 6" OC #4 STIRRUPS 2" (4) #10 TOP TYP Lb (4) #8x40'-0" BOT 3 405-SZD508 TYP Lb 2" 10 @ 6" OC #4 STIRRUPS REMAINING @ 24" OC #4 STIRRUPS 10 @ 6" OC #4 STIRRUPS 2" (4) -#10 TOP x 34'-0"2-#6 TOP, TYP UNO(4) #10 TOP (2) #8 BOT (2) #8 BOT (2) #6 TOP, TYP UNO (4) #10 TOP (2) #8 BOTTYP PT PROFILE. SEE PLAN FOR PROFILE & QUANTITY 2" 10 @ 6" OC #4 STIRRUPS REMAINING @ 24" OC #4 STIRRUPS 10 @ 6" OC #4 STIRRUPS 2" COL WHERE OCCURS (4) #8 x40'-0" BOT TYP Lb (4) #8 x40'-0" BOT GRID GRID GRID 3 405-SZD508 GRID GRID INDICATES TENDON PROFILE POINT INDICATES TENDON INFLECTION POINT L/2 UNO L/2 UNO h2L ** L/10 L/10 0.2 h1 0.2 h2 *h1* NOTES: 1. SEE PLAN FOR TENDON PROFILE POINT VALUES. DIMENSIONS GIVEN ARE FROM BEAM SOFFIT TO CENTER OF GRAVITY OF TENDONS. 2. INSTALL TENDON WTH PARABOLIC DRAPE BETWEEN PROFILE AND INFLECTION PONTS. 3. PROVIDE TENDON SUPPORT AT EACH HIGH POINT, LOW POINT AND AT 48" MAXIMUM SPACING THROUGHOUT. 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:16 PM405 68 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZD507 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL TYPICAL CONCRETE DETAILS SOUTH RENTON TRANSIT CENTER SCALE: 1/4" = 1'-0" TYPICAL SINGLE SPAN PT BEAM REINFORCEMENT DETAILS 1 SCALE: 3/16" = 1'-0" TYPICAL MULTI SPAN PT BEAM REINFORCEMENT DETAIL 3 SCALE: 1/4" = 1'-0" TYPICAL SINGLE SPAN PT BEAM REINFORCEMENT DETAILS 2 2'-6"FOR GIRDER REINF AND LAP LOCATIONS SEE BEAM ELEVATIONS (3) #4 EF PT SLAB REINF PER PLAN PT SLAB TENDONS 3'-0"PLANPER1/2" MIN CHAMFER #4 STIRRUPS SEE EL FOR SIZE & SPACING PT TENDON SUPPORT BAR PER ADDED SLAB TOP REINF OVER GIRDER, SEE PLAN 2 405-SZD508 2'-6"(2) #4 CONT CONT TOP REINF BARS PER BEAM ELEVATIONS CHAIR & #4 TIE BARS EA SIDE OF BEAM SEE PLAN SLAB TOP BARS SUPPORTED TO MAINTAIN SCHEDULED COVER, SEE PLAN 1" 1'-4" 1"PLANPER1/2" MIN CHAMFER (2) #4 CONT MID DEPTH BOT REINF PER BEAM ELEVATIONS #4 STIRRUPS PT TENDON SUPPORT BAR PER EQEQEQ2 405-SZD508 SUPPORT BAR HOOKS MAY BE TURNED UP BEAM PER PLAN TENDON BUNDLES #4 PT TENDON SUPPORT BAR EQ EQ BEAM STIRRUP SECURE SUPPORT BARS TO BEAM STIRRUPS NOTES: 1. PROVIDE SUPPORT BARS AS REQD TO MAINTAIN PROPER PROFILE. MAXIMUM SPACING TO BE PER POST-TENSIONING NOTES. 2. LOAD TENDONS IN EQUAL BUNDLES WHENEVER POSSIBLE. (2) #4 8" FACE BAR #4 @ 12" OC SLAB REINF PER PLAN #5 @ 12" OC24"36"3'-4"- #5 @ 12" OC MIN SLOPE TOP TO INT 1/4" PER FT 1'-6"#5x5' - 0" @ SIM BEAM BELOW @ SIM (2) #4 FACE BAR #4 @ 10" OC, TYP 4"7"3'-4"1" GAP BARRIER WALL PER PLAN COL PER PLANCOL PER PLAN TOS 1" GAP 4 405-SZD508 GRID PLANPER1 1/2"1'-6" 4" 1/2" CHAMFER, TYP CABLE RAIL 4"1'-6"PLANPER1 1/2"#4 @ 12" TYP 60" GRID 4"6"6"CABLE RAIL PLANPER1"NOTE: 1.FOR INFO NOT SHOWN SEE 1'-6" 1'-0"PLANPER1 1/2"4" 5 405-SZD508 SCALE: 3/4" = 1'-0"405-SGP502 TYPICAL PT GIRDER 1 SCALE: 3/4" = 1'-0"405-SZD507 TYPICAL PT BEAM SECTION 3 SCALE: 3/4" = 1'-0"405-SZD508 TYPICAL TENDON SUPPORT 2 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:17 PM405 69 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZD508 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL TYPICAL CONCRETE DETAILS SOUTH RENTON TRANSIT CENTER SCALE: 3/4" = 1'-0"405-SGP502 TYPICAL BARRIER WALL 4 SCALE: 3/4" = 1'-0"405-SZE501 TYPICAL BARRIER WALL 7 SCALE: 1" = 1'-0"405-SGP502 SLAB EDGE AT RAMP 5 SCALE: 1" = 1'-0"405-SGP505 SLAB EDGE AT RAMP 6 STIRRUPS W/ 180° STD HOOK EA END PER SCHED. ALT & ROTATE AS REQD TO FIT IN CELL BOTTOM REINF PER SCHED WIDTH (W) CLEAR SPAN BOTTOM REINF 8" & 12" UP TO 10'-4" (2) #5 CMU LINTEL SCHEDULE MARK L1 L2 L3 LINTEL BLOCK(SEE SCHED)D8" & 12" 8" & 12" UP TO 8'-0" UP TO 4'-0" DEPTH (D) 1'-4" 2'-0" 2'-8" (2) #5 (2) #5 TOP REINF (2) #5 (2) #5 (2) #5 STIRRUPS #4 @ 16" OC #4 @ 16" OC #4 @ 8" OC NOTES: 1. DO NOT SPLICE HORIZ LINTEL REINF 2. WHERE BOND BEAM OCCURS WITHIN LINTEL DEPTH, RUN BOND BEAM REINFORCEMENT CONTINUOUS ACROSS OPENING.3"TOP REINF PER SCHED W SECTION AT LINTEL TO OPNG PER ARCH 1'-4" . AT OPENING UP TO 10'-0" HORIZ REINF W/ STD HOOK. ROTATE AS NECESSARY TO FIT IN CELL SIZE OF BAR TO MATCH VERT CMU WALL REINF. PROVIDE (2) BARS TO FLR ABOVE OPENING 1'-4"1'-4" . AT OPENING UP TO 4'-0" GROUT REINF CELLS FULL HT PLAN AT JAMB . AT OPENING UP TO 12'-0" 8" 2'-0" TERMINATE HORIZ REINF 2" FROM CJ TYP UNO VERT REINF EA SIDE OF JOINT NOTE 1. ALIGN BOND BEAM CONTROL JOINTS WITH WALL CONTROL JOINTS. 2. COCNRETE BLOCK SHOWN. (BRICK SIMILAR) BOND BEAM REINF PENETRATES CJ BACKER ROD & SEALANT AT VERT CJ PROVIDE CLOSED END BLOCKS AT CJ, TYP TYPICAL BOND BEAM BOND BEAM AT FLOOR AND ROOF CL CONTROL JOINT CL CONTROL JOINT PREMOLDED JOINT FILLER LINTEL BEAM REINF PER SCHED TYP VERT WALL REINF UNO W/ STD HOOK INTO LINTEL JAMB REINF IN CELL ADJACENT TO OPENING DOWELS TO MATCH VERT REINF TYP TYP PER ARCH HORIZ REINF W/ HOOK WHERE Ld (24" MIN) EXTENSION NOT POSSIBLE Ld Ld LspTOC EL PER PLAN CONC WALL OR COLUMN BREAK SHELL FOR FLOW OF GROUT 16 GA DOVETAIL ANCHOR @ 16" OC VERT @ INTERSECTIONS VERT @ CORNERSAT FREE END AT INTERSECTION AT CORNER VERT AT FREE END CORNER BAR TO MATCH HORIZ REINF TYP LdALT HOOKLd BOND BEAM AT FIRST COURSE, TYP FOUNDATION DOWEL TO MATCH WALL VERT REINF. REFER TO CMU WALL VERT REINF SCHED FOR SIZE & SPACING BOND BEAM AT TOP OF WALL BOND BEAM @ 4'-0" OC MAX & WHERE SHOWN HOLD TOP OF EA GROUT LIFT 2" BELOW TOP OF BLOCK TO PROVIDE KEY FOR NEXT LIFT. USE LOW LIFT METHOD OF GROUTING (MAX GROUT LIFT = 5'-4") NOTES: 1. GROUT REINFORCED CELLS SOLID. 2. CMU SHALL BE LAID IN RUNNING (COMMON) BOND. 3. REFER TO ARCH FOR CMU ELEVATIONS. 4. FOR REINF AT OPENINGS SEE 5. FOR REINF AT CORNERS, INTERSECTIONS, AND FREE END SEE 6. PROVIDE BAR POSITIONERS FOR VERTICAL REINF IN TWO LAYERS OR AT FACE OF WALL. SEE 7. HORIZONTAL REINF TO BE PLACED IN BOND BEAMS EXCEPT OVER OPENINGS WHERE HORIZONTAL REINF IS TO BE PLACED IN LINTEL BLOCK. SEE CMU LINTEL SCHEDULE. 8. WHERE TOP OF WALL IS NOT A COURSING DIM, CUT 2ND COURSE FROM TOP OF WALL UNO. 9. SPLICE VERT REINF IN 6'-0" TO 8'-0" LENGTH NOMINAL WIDTH (W)VERT REINF HORIZ REINF IN BOND BEAM 8" #5 @ 24" OC (2) #5 @ 4'-0" OC CMU WALL REINFORCEMENT SCHEDULE MARK W1 NOTES TOC EL PER PLANLsp (LAP SPLICE)/3 405-SZD509 /1 405-SZD509 /5 405-SZD509 VERT BAR POSITIONER NOTE: VERTICAL BAR POSITIONERS REQUIRED WHEN REINFORCEMENT IS AT FACE OF WALL OR IN TWO LAYERS 8" CMU 2 1/2"2 1/2" SCALE: 1" = 1'-0" CONTROL JOINT AT CMU WALL 4 SCALE: 1/2" = 1'-0" TYPICAL CMU WALL OPENING REINFORCEMENT 3 SCALE: 1" = 1'-0" TYP HORIZ REINF PLACING DETAIL - CMU 1 SCALE: 1" = 1'-0" TYP CMU WALL REINF AND SCHEDULE 2 SCALE: 1 1/2" = 1'-0" VERT REINF BAR POSITIONER 5 35381LARSERIK H O LTESTATE O F WASHIN G TONPROF E SSIONAL E N G IN EERSTRUC TURAL E N G IN EERNOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARYTHE STRUCTURAL DRAWINGS ARE CONCEPTUAL IN NATURE AND NOT INTENDED TO REPRESENT A FINAL DESIGN SOLUTION. FOUNDATION DETAILS OR STRUCTURAL MEMBERS (I.E., BEAM TYPE OR LOCATION) DEPICTED ARE NOTIONAL AND SHOULD NOT BE TAKEN AS AN INDICATION OF MEETING OR EXCEEDING DESIGN REQUIREMENTS. THE DESIGNER OF RECORD (DOR) SHALL ENSURE ALL DESIGN REQUIREMENTS ARE IDENTIFIED, MET, AND AN OPTIMAL SOLUTION PROVIDED.BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-S-v2020.rvt2/3/2022 12:21:17 PM405 70 0 BRT-405-SZN-500 AE 0054-17 02/11/2022 I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-SZD509 02/11/2022R. GORMAN PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL STRUCTURAL TYPICAL CMU DETAILS SOUTH RENTON TRANSIT CENTER EACHEASTEAST BOUNDELECTRIC, ELECTRICALELEVATIONELEVATOREMERGENCYEMERGENCY MANAGEMENT PANELEQUALEQUIPMENTEMERGENCY TELEPHONEEMERGENCY TRIP SWITCH/STATIONEXHAUSTEXISTING EXPANSION BOLTEMERGENCY VENTILATION SYSTEMEXPOSED, EXPANSIONEXTERIORFIRE MARSHALLFACE OFFACE OF CONCRETEFACE OF FINISHFACE OF MASONRYFACE OF STUDSFARE GATEFEET, FOOTFLAT HEAD/FIRE HYDRANTFINISH, FINISHEDFINISH FLOOR ELEVATIONFINISH FLOOR LINEFIRE ALARMFIRE-RATEDFIRE EXTINGUISHER (CABINET)FIRE HOSE CABINETFLASHINGFLEXIBLE CONNECTIONFLOOR, FLOORINGFLOOR CLEANOUTFLOOR DRAINFLUORESCENTFRESH AIR INTAKEFLOOR SINKFURNISHED BY OTHERSGAGE, GAUGEGALVANIZEDGALVANIZED SHEET METALGLASS, GLAZINGGRAB BARGRANITEGYPSUMGENERALGROUNDGLASS FIBER REINFORCED CONCRETETELEPHONEHANDHOLEHARDWAREHEADERHEATING/VENTILATING/ AIR CONDITIONINGHEAVY DUTYHEIGHTHEXAGONALHOLLOW METALHORIZONTALHOSE BIBBHIGH WORKING POINTHIGH POINTHIGH DENSITY POLYETHYLENE MEMBRANEINTERNATIONAL BUILDING CODEINSIDE DIAMETERINSULATE, INSULATED, INSULATIONINTERIORINVERTINCH, INCHESINCLUDINGEAEEBELECTELELEVEMERGE.M.PEQEQUIPE TELE.T.SEXHEXIST (E)E.BE.V.S. EXPEXTFMF.OF.O.CF.O.FF.O.MF.O.SF.GFTF.HFINF.F.EF.F.LF.AF.RF.E.CF.H.C.FLGF.CFLR, FLFL COF.DFLUORF.A.IF.SF.B.OGAGALVG.S.MGLG.BGRNGYPGENGRDG.F.R.CTELHHHDWHDRH.V.A.CH.DHTHXH.MHORIZH.BH.W.PH.PH.D.P.EIBCI.DINSULINTINVIN OR INCLAVENUEABOVEABOVE FINISHED FLOORABOVE SUSPENDED CEILINGAMERICAN SOCIETY FOR TESTING AND MATERIALS ACCESSACCESS PANELACOUSTIC, ACOUSTICALAMERICAN WITH DISABILITY ACTADDITIONALADHESIVEADJUSTABLEAGGREGATEALTERNATEALUMINUMANCHOR BOLTANCHORANODIZEDARCHITECT, ARCHITECTURALARCHITECT/ENGINEERAREA DRAINAUTOMATICAUXILIARYAUXILIARY POWER ROOMAPPROXIMATEBEAMBELOWBETWEENBEVELEDBLOCKINGBLUE LIGHT SWITCH/STATIONBOARDBOTH SIDESBOTTOMBRONZEBUILDINGBENCHMARKBOULEVARDCABINETCAST IRONCAST-IN-PLACE (CONCRETE)CATCH BASINCEILINGCEMENTCERAMICCHAMFERCLEAR, CLEARANCECLOSED CIRCUIT T.V. CAMERACOLUMNCOMPOSITIONCONCRETECONCRETE MASONRY UNITCONVENIENCE OUTLET, CLEAN OUTCONSTRUCTIONCONTINUE, CONTINUOUSCONTROL JOINTCOPPERCORNER GUARDCHAIN LINKCARD READERCOUNTERSUNK SCREW, COUNTERSINKCOMMUNICATIONS & SIGNALINGAVEABVA.F.FA.S.CA.S.T.MACCA.PACADAADD'LADHADJAGGALTAL, ALUMA.BANCHANODARCHA/EADAUTOAUXAPRAPPROXBMBELBTWBVLBLKGB.L.SBDB.SBOT, BTMBRZBLDGB.MBLVD, BLCABC.IC.I.PC.BCLGCEMCERCHAMCLRC.C.T.VCOLCOMPOCONCC.M.UC.OCONSTCONTC.JCPRC.GC.LC.RCTSKC & SANGLECENTER LINEDIAMETERPERPENDICULARSQUARE FEETLVLLTGLAMLAVLTLWL.PL.W.PLLINLONGITL.C.S.MBHMFRM.OMAXMECHMEDMTL, METMINMIRMISCMTDMTGMEZZNB N.R.CNOMN/RN/ANO., #NN.I.CNTSO/O.A.IOBSO.COPOPNGOPPO.DO.AO.S.ALEVELLIGHTINGLAMINATE, LAMINATEDLAVATORYLIGHTLIGHTWEIGHTLOW POINTLOWER WORKING POINTLENGTHLINEARLONGITUDINALLOCAL CONTROL STATIONMANHOLEMANUFACTURER MASONRY OPENINGMAXIMUMMECHANIC, MECHANICALMEDIUMMETALMINIMUMMIRRORMISCELLANEOUSMOUNT, MOUNTEDMOUNTINGMEZZANINENORTH BOUND NOISE REDUCTION COEFFICIENTNOMINALNON-RATEDNOT APPLICABLENUMBERNORTHNOT IN CONTRACTNOT TO SCALEOVEROUTSIDE AIR INTAKEOBSCUREON CENTER, CENTERSOPAQUEOPENINGOPPOSITEOUTSIDE DIAMETEROVERALLOUTSIDE SUPPLY AIRSBS.F.C.US.FSECTSHTSIMSSPECSQSTDSTASTLSTRUCTSYMS.SSTSCHEDSPKRT/C T.D.DTELTVT.V.MTHKT.O.T.O.ST.O.CT.O.WTTWSTYPT.DSOUTH BOUNDSTATION FARE COLLECTION CONTROL UNITSQUARE FEETSECTION SHEETSIMILARSOUTHSPECIFICATION, SPECIFICATIONSSQUARESTANDARDSTATION (ALIGNMENT)STEELSTRUCTURALSYMMETRY, SYMMETRICALSTAINLESS STEELSTREETSCHEDULESPEAKERTOP OF CURBTELECOMMUNICATION DEVICE FOR THE DEAFTELEPHONETELEVISIONTICKET VENDING MACHINETHICK, THICKNESSTOP OFTOP OF STEELTOP OF CONCRETETOP OF WALLTREADTACTILE WARNING SURFACINGTYPICALTRENCH DRAINØCLU.N.OU.W.PV.C.TVENTVERTVESTV.M.SWBW.S.PW.TWPW.W.MW.W.FWW/OWDW.PW/UNLESS NOTED OTHERWISEUPPER WORKING POINTVINYL COMPOSITION TILEVENTILATIONVERTICALVESTIBULEVARIABLE MESSAGE SIGNWEST BOUNDWET STAND PIPEWATER TABLEWATERPROOFINGWELDED WIRE MESHWELDED WIRE FABRICWEST, WIDTHWITHOUTWOODWORKING POINTWITHDEG OR °DETDIAGDIA DIMDIVDRDTADTSDWGD.FDND.IDEGREEDETAILDIAGONALDIAMETERDIMENSIONDIVISIONDOORDOVETAIL ANCHORDOVETAIL ANCHOR SLOTDRAWINGDRINKING FOUNTAINDOWNDRAIN INLETPROJPVCPARPARTPERFP LAMPLPLUMPTPSFPSIPROPP.LPCP TELLB OR LBSQ.TPROJECTIONPOLYVINYL CHLORIDEPARALLELPARTIALPERFORATE, PERFORATEDPLASTIC LAMINATEPLATEPLUMBINGPOINTPOUNDS PER SQUARE FOOTPOUNDS PER SQUARE INCHPROPERTYPROPERTY LINEPRECASTPASSANGER ASSISTANCE TELEPHONEPOUND, POUNDSQUARRY TILERTRAD, RREFREFLRESREINFREVR.O.WRR.DRFGRMR.OR.BREQ'DRDRIGHTRADIUSREFERENCEREFLECT, REFLECTED, REFLECTIVE, REFLECTORRESILIENTREINFORCINGREVISION, REVISIONS, REVISED, REVERSERIGHT-OF-WAYRISER, RADIUSROOF DRAINROOFINGROOMROUGH OPENINGRUBBER BASEREQUIREDROAD JANITOR'S CLOSETJOINTJOINT FILLERKNOCKOUT PANELJ.CJTJ.FK.O.P.EXTERIOR ELEVATIONCOLUMN GRIDELEVATION DATUMSECTION DESIGNATION(LETTER)DETAIL DESIGNATION (NUMBER)VIEW DESIGNATION (LETTER)DRAWING NO. ON WHICH SECTION APPEARSDRAWING NO. ON WHICH VIEW APPEARSMATCH LINEELEVATION (FINISH FLOOR, SURFACE U.N.O OR SPOT ELEVATION)REF NO.VIEW TITLEALIGN EDGESCENTERLINEROOM TAGNORTH ARROWVEHICLE CIRCULATIONCLSCALE IN FEETSCALE: 1/16" = 1'-0"0161632Axxx-xxx-xxx0NameElevationAXXX-XXXXXSIM-1NVIEW NAMESCALE 1/8"=1'-0"1405-APP501405-APP501ROOM NAME1001GRAPHIC SCALEMARKDESCRIPTIONMATCH LINESEE DRAWINGNOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONNTSPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:23:13 PM405710BRT-405-AZN500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-AZN50102/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGENERAL ARCHITECTURAL ABBREVIATIONS & SYMBOLSSOUTH RENTON TRANSIT CENTERARCHITECTURAL ABBREVIATIONSSYMBOLS NOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONNTSPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:23:13 PM405720BRT-405-AZN500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-AZN50202/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGENERAL ARCHITECTURAL NOTESSOUTH RENTON TRANSIT CENTERGENERAL NOTES:1.BEFORE BEGINNING WORK AT THE SITE AND THROUGHOUT THE COURSE OF CONSTRUCTION, INSPECT AND VERIFY THE LOCATION AND CONDITION OF ITEMS AFFECTED BY THE WORK UNDER THIS CONTRACT, REPORT DISCREPANCIES TO ARCHITECT PRIOR TO PERFORMING WORK RELATED TO THOSE DISCREPANCIES. ALSO SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.2.COORDINATE ALL OPENINGS IN FLOORS, WALLS, PARTITIONS, CEILINGS, AND SLEEVES THROUGH STRUCTURE WITH CIVIL, ARCHITECTURAL, MECHANICAL, AND ELECTRICAL WORK.3.COORDINATE ALL OPERATIONS WITH OWNER INCLUDING STAGING AREAS, MATERIAL STORAGE, ACCESS TO WORK, TIMING OF WORK, SPECIAL CONSIDERATIONS FOR NOISY OPERATIONS, INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES, ETC.4.PROVIDE GALVANIC SEPARATION MATERIAL BETWEEN DISSIMILAR METALS.5.AT INSTALLATION OF ALL VAPOR BARRIERS, PROVIDE AT LEAST TWELVE INCHES OF OVERLAP BETWEEN INDIVIDUAL SHEETS AND TAPE ALL JOINTS. SHOULD THE MATERIAL BE TORN OR PUNCTURED, PATCH BY ADDITION OF MATERIAL OVER AFFECTED AREA WITH AT LEAST 12" COVERAGE BEYOND DAMAGED AND TAPE JOINTS.6.ALL CASEWORK, CABINETS, AND RACKS SHALL BE SECURELY ANCHORED TO WALLS AND FLOORS TO CONFORM TO SEISMIC SUPPORT REQUIREMENTS.7.PROVIDE BACKING/BLOCKING FOR ALL WALL MOUNTED EQUIPMENT. PROVIDE BLOCKING FOR ALL CASEWORK, COUNTERS, WALL STOPS (DOORS), AND FIXTURES. VERIFY ALL MOUNTING HEIGHTS AND STRUCTURAL SUPPORT REQUIREMENTS WITH EQUIPMENT MANUFACTURERS BEFORE INSTALLING BACKING AND SUPPORTS.DIMENSION NOTES:1.IF DIMENSIONAL DISCREPANCIES ARE ENCOUNTERED CONTACT THE ARCHITECT FOR ADDITIONAL INFORMATION. CONTRACTOR SHALL CONFIRM DIMENSIONS WITH ARCHITECT PRIOR TO CONSTRUCTION OF THE AFFECTED AREA.2.ACTUAL CONSTRUCTION CONDITIONS AND/OR MATERIAL AND EQUIPMENT SIZES MAY NOT BE THOSE ANTICIPATED BY THE DESIGNERS. THROUGH FIELD INVESTIGATION AND SHOP DRAWINGS, CONTRACTOR SHALL VERIFY DIMENSIONS OR RECOMMEND DIMENSIONAL MODIFICATIONS.3. ADDITIONAL ARCHITECTURAL DIMENSIONS MAY BE FOUND ON ENLARGED PLANS, SECTIONS AND ELEVATIONS.4. OTHER DIMENSIONS MAY BE SHOWN ON CIVIL, LANDSCAPE, STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS. MECHANICAL AND ELECTRICAL EQUIPMENT MAY ALSO CONTAIN DIMENSIONAL INFORMATION RELATED TO EQUIPMENT SIZES AND CLEARANCES.5. GRID LINE IDENTIFICATION: GRID LINES IDENTIFY AND PROVIDE POINTS FOR DIMENSIONING MAJOR ALIGNED VERTICAL STRUCTURAL ELEMENTS6.GRID LINE LOCATIONS: GRID LINES ARE SHOWN AT THE CENTERLINES OF COLUMNS WHEN COLUMNS ARE THE PRINCIPAL VERTICAL STRUCTURAL ELEMENTS, UNLESS NOTED OTHERWISE.7.WHEN COLUMNS ARE NOT THE PRINCIPAL VERTICAL STRUCTURAL ELEMENTS, GRID LINES ARE TO THE FACE OF THE STRUCTURAL ELEMENT OF THE WALLS SUCH AS FACES OF LOAD BEARING STUDS, UNFINISHED FACES OF LOAD BEARING MASONRY, UNFINISHED FACES OF PRE-CAST CONCRETE AND UNFINISHED FACES OF CAST-IN-PLACE CONCRETE WALLS, UNLESS THESE WALLS ARE ALIGNED WITH COLUMNS OR OTHER DEFINING ELEMENTS (SUCH AS RIDGE LINES), IN WHICH CASE, THE GRIDLINE LOCATION IS NOTED AS FOLLOWS: WALL-CENTERED GRID LINES ARE NOTED COS (CENTER OF STUD), COM (CENTER OF MASONRY), COC (CENTER OF CONCRETE), ETC.8. DIMENSIONS FOR NON-LOAD BEARING WALLS ARE TO ONE FACE OF THE STUDS (FOS), ONE FACE OF MASONRY WALLS (FOM), ONE FACE OF CONCRETE WALLS (FOC), ONE FACE OF WALL (FOW), ETC, UNLESS NOTED OTHERWISE.9. DOOR AND WINDOW DIMENSIONS IN MASONRY AND CONCRETE WALLS ARE FOR “ROUGH”OPENINGS LOCATION (FACES OF MASONRY OR CONCRETE).10. DOOR AND WINDOW OPENINGS SHOWN IN PLAN ARE FOR DOOR LEAF/WINDOW OPENING SIZE. ADJUST THE "ROUGH" OPENINGS FOR FRAMES. TYPICAL CLEAR AT FRAMES SHOULD ALLOW FOR 1/4" CLEAR EACH SIDE OF FRAME AND 1/2" AT THE HEAD OF FRAME.11. STOREFRONT DIMENSIONS IN MASONRY OR CONCRETE SHALL ADJUST "ROUGH" OPENINGS FOR FRAMES. TYPICAL CLEAR AT FRAMES SHOULD ALLOW FOR 1/2" CLEAR EACH SIDE OF FRAME AND 1/2" AT THE HEAD/SILL DIMENSION.12.“TYPICAL”CLEARANCE DIMENSIONS BETWEEN DOOR FRAMES AND FACE OF STUDS AT NEARBY PERPENDICULAR WALLS ARE TYPICALLY 4”DEPENDING ON HARDWARE CLEARANCES (3”-DOOR HANDLES PLUS 1”-WALL STOPS = 4”). DOORS WITH COAT HOOKS TYPICALLY REQUIRE 6”CLEARANCE.13.SOME DIMENSIONS REQUIRED TO BE CLEAR, SUCH AS AT EXIT WAYS OR PREFABRICATED STAIR ENCLOSURES ARE NOTED “CLR”AND ARE SHOWN TO THE FACES OF FINISHES.14. TYPICAL DIMENSIONS FOR SPECIALTIES, FIXTURES AND EQUIPMENT MAY BE FOUND ON “PROTOTYPE DETAILS”. THESE INCLUDE TOILET STALLS, LAVATORIES, CASEWORK, EQUIPMENT LOCATIONS, ETC.15.THE FIRST FLOOR REFERENCE (LEVEL 1) ELEVATION IS 0'-0".SEALANT NOTES:1.THE OBJECT OF APPLYING SEALANT IS TO FACILITATE WEATHER TIGHTNESS AT THE EXTERIOR BUILDING ENVELOPE AND WATER TIGHTNESS AT INTERIOR WET/DAMP LOCATIONS. PROPER PRIMING MUST BE USED WITH SEALANTS. THE OBJECT OF APPLYING CAULKING IS TO ENHANCE APPEARANCE AND FINISH AT INTERIOR APPLICATIONS AND IN SOME SITUATIONS TO REDUCE AIRFLOW, SUCH AS AT DUCTS, INTERIOR SIDES OF THEEXTERIOR ENVELOPE AND AT FIREWALL/SMOKE BARRIER PENETRATIONS AND TO DECREASE SOUND TRANSMISSION THROUGH WALLS AND CEILINGS. OTHER USES MAY BE NOTED IN THE SPECIFICATIONS AND/OR ON THE DRAWINGS. IF THERE ARE QUESTIONS ABOUT WHERE OR WHAT TYPE OF SEALANT OR CAULKING SHOULD BE USED, CONTACT THE ARCHITECT.2.SPECIFIED SEALANT AND BACKER RODS SHALL BE APPLIED AT BOTH INTERIOR AND EXTERIOR CONTROL AND EXPANSION JOINTS AND/OR AS NOTED ON DRAWINGS.3.SPECIFIED SEALANT AND BACKER RODS SHALL BE USED AT HORIZONTAL AND VERTICAL TILE CONTROL AND EXPANSION JOINTS.4.SPECIFIED SEALANT AND BACKER ROD SHALL BE USED AT MASONRY AND CONCRETE CONTROL JOINTS. IN SOME CASES, SEALANT MAY BE REQUIRED AT EXPANSION OR SEISMIC JOINTS, WITH OR WITHOUT MECHANICAL COVERS. REFER TO DETAIL DRAWINGS FOR ADDITIONAL INFORMATION.5.SET EXTERIOR THRESHOLDS IN CONTINUOUS SEALANT UNLESS NOTED OTHERWISE.6.SPECIFIED SEALANT SHALL BE USED ALL AROUND BOTH SIDES OF HOLLOWMETAL DOOR AND WINDOW FRAMES.7.SPECIFIED SEALANT SHALL BE USED ALL AROUND BOTH SIDES OF EXTERIORDOOR AND WINDOW FRAMES.8.SPECIFIED SEALANT SHALL BE USED AT JOINTS BETWEEN DIFFERENT WALLMATERIALS (CMU TO GYPSUM BOARD ETC). USE SPECIFIED SEALANT AT WALLMATERIAL GAPS OF 1/16TH INCH OR MORE UNLESS THE GAP IS SHOWN AS AN ARCHITECTURAL "REVEAL."9.SPECIFIED SEALANT SHALL BE USED WHERE COUNTERTOPS AND BACK SPLASHES MEET WALLS.10.SET FAUCETS, LAVATORIES, SINKS, SOAP DISPENSERS AND OTHER COUNTER MOUNTED FIXTURES IN A CONTINUOUS BEAD OF SPECIFIED SEALANT. SEAL AROUND WALL MOUNTED WATER CLOSETS, URINALS, MOP SINKS AND OTHER WALL AND FLOOR MOUNTED FIXTURES.11.USE SPECIFIED SEALANT AT THE INTERSECTIONS OF WALLBOARD, FLOORS ANDHARD CEILINGS (BUT NOT ACOUSTICAL OR LAY-IN CEILINGS) TO AID ACOUSTICAL SEPARATION. AT A MINIMUM THIS SHALL INCLUDE CORRIDOR WALLS, TOILET ROOM WALLS, ALL EXTERIOR WALLS AND OTHER WALLS INDICATED AS ACOUSTICAL.12.USE SPECIFIED SEALANT AROUND WALL, FLOOR AND HARD CEILING PIPE PENETRATIONS. WHERE ESCUTCHEONS ARE SPECIFIED OR PROVIDED, SET THE ESCUTCHEON IN A BEAD OF SEALANT.13.USE SPECIFIED SEALANT AROUND PENETRATIONS IN EXTERIOR WALLS ANDSOFFITS, SUCH AS AT HOSE BIBS, FD CONNECTIONS, ELECTRIC SERVICE ENTRIES, GAS PIPE ENTRIES, ELECTRIC OUTLETS, LIGHTING, VENTS, ETC.14.USE FIRE-RATED SEALANT AT ALL PENETRATIONS OF RATED WALLS AND FLOORS AS REQUIRED BY CODES AND SPECIFICATIONS. NOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONNTSPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:23:14 PM405730BRT-405-AZN500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-AZN50302/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALBUILDING CODE INFORMATIONSOUTH RENTON TRANSIT CENTERAREA ALLOWED PER TIER:OPEN PARKING, TYPE IIB ALLOWED AREA PER TIER: (50,000 + 25% INCREASE ) 62,500 SF/TIER(IBC 2018, 406.5.5)MAX AREA PROVIDED: 52,122 SF/ TIER (@ FIRST LEVEL AREA INCLUDES CANOPIES)IBC 2018, 406.5.5 AREA AND HEIGHT INCREASE: GARAGES WITH SIDES OPEN ON THREE-FOURTH OF THE BUILDING'S PERIMETER ARE PERMITTED TO BE INCREASED BY 25% IN AREA AND ONE TIER IN HEIGHT. FOR SIDES TO BE CONSIDERED OPEN, THE TOTAL AREA OF OPENINGS ALONG THE SIDE SHALL BE NOT LESS THAN 50% OF THE INTERIOR AREA OF THE SIDE AT EACH TIER AND SUCH OPENINGS SHALL BE EQUALLY DISTRIBUTED ALONG THE LENGTH OF THE TIER. FOR PURPOSES OF CALCULATING THE INTERIOR AREA OF THE SIDES, THE HEIGHT SHALL NOT EXCEED 7FT.HEIGHT ALLOWED (IN TIER):8+1 TIERS (IBC 2018 TABLE 406.5.4 & 406.5.5)HEIGHT PROVIDED (IN TIER):5 TIERSVERTICAL BARRIERS (IBC 2018 406.4.2):2'-9" MINALLOWABLE BUILDING HEIGHT:75 FT FOR FULLY SPRINKLER TYPE IIBS-2 BUILDING (IBC 2018 TABLE 504.3) HOWEVER, THE RENTON MUNICIPAL CODE ALLOWS A LOWER BUILDING HEIGHT OF 65 FT. MAX BUILDING HEIGHT PROVIDED:64'-1 1/2"FIRE RESISTANCE REQUIREMENTS PER(IBC TABLE 601):• PRIMARY STRUCTURAL FRAME:0 HRS• EXTERIOR BEARING WALLS:0 HRS• INTERIOR BEARING WALLS0 HRS• NON BEARING WALLS AND PARTITIONS:0 HRS• FLOOR CONSTRUCTION:0 HRSOCCUPANT LOAD CALCULATION (IBC 2018 TABLE 1004.5SPACE OCCUPANCY AREA LOAD OCCUPANTSLEVEL 1PARKING PARKINGGARAGES45,464 SF 200 GROSS 228ELEVATOR MACHINE ROOM EQUIPMENTROOM579 SF 300 GROSS 2SECURITY ROOM BUSINESS AREA 178 SF 150 GROSS 2LACTATION ROOM BUSINESS AREA 109 SF 150 GROSS 1SPRINKLER ROOM EQUIPMENTROOM282 SF 300 GROSS 1ELECTRICAL ROOM EQUIPMENTROOM491 SF 300 GROSS 2GENERATOR ROOM EQUIPMENTROOM409 SF 300 GROSS 2JANITOR ROOM ACCESSORYSTORAGE200 SF 300 GROSS 1STORAGE ACCESSORYSTORAGE451 SF 300 GROSS 2COMMUNICATIONS ROOM EQUIPMENTROOM407 SF 300 GROSS 2KING COUNTY PANELS EQUIPMENTROOM46 SF 300 GROSS 1LEVEL 2PARKING PARKINGGARAGES49, 011 SF 200 GROSS 246COMMUNICATIONS CLOSET EQUIPMENTROOM197 SF 300 GROSS 1COMMUNICATIONS CLOSET EQUIPMENTROOM180 SF 300 GROSS 1ELECTRICAL CLOSET EQUIPMENTROOM178 SF 300 GROSS 1LEVEL 3PARKING PARKINGGARAGES49, 557 SF 200 GROSS 248LEVEL 4PARKING PARKINGGARAGES49, 011 SF 200 GROSS 246COMMUNICATIONS CLOSET EQUIPMENTROOM197 SF 300 GROSS 1COMMUNICATIONS CLOSET EQUIPMENTROOM180 SF 300 GROSS 1ELECTRICAL CLOSET EQUIPMENTROOM178 SF 300 GROSS 1LEVEL 5PARKING PARKINGGARAGES49, 557 SF 200 GROSS 248TOTAL BUILDING OCCUPANT LOAD (SEE TABLE ABOVE): 1, 238MIN NUMBER OF EXITS OR ACCESS TO EXITS PER STORY(IBC 2018 TABLE 1006.3.2)REQUIRED:2PROVIDED:2MEANS OF EGRESSSTAIRWAYS (IBC 2018 1005.3.1):No OCCUP X 0.3 INCH OR 36 INCHES (WHICHEVER IS GREATER)MIN STAIR WIDTH PROVIDED:72 INCHESTREAD AND RISER (IBC 2018 1011):11 INCHES MIN & 7 INCHES MAX RESPECTIVELYHANDRAILS (IBC 2018 1014):34 INCHES MIN 38 INCHES MAXGUARDRAILS (IBC 2018 1015):NOT LESS THAN 42 INCHES MEASURED VERTICALLY FROM WALKING SURFACESDOORS WIDTH (IBC 2018 1010):No. OCCUP X 0.2 INCHES OR 32 INCHES (WHICHEVER IS GREATER)MIN DOOR WIDTH PROVIDED:36 INCHES (@ ROOMS)36 INCHES (@ BUILDING EXITS)PERSONNEL DOORS (NFPA 70 110.26(C)(3)ELECTRICAL ROOM W/ 800A OR MORE:ELEC ROOMDOOR TO HAVE PANIC HARDWARESTAIR ENCLOSURE: NOT REQUIRED PER IBC 2018 1019.3AREA OF REFUGE:NOT REQUIRED PER IBC 2018 1009.3.3EXIT ACCESS TRAVEL DISTANCE (IBC 2018 1017.2)FOR S-2 OCCUPANCY WITH SPRINKLER:400 FEETEXIT STAIR CONFIGURATION (IBC 2018 1007.1)MAX OVERALL DIAGONAL DIMENSION OF THE AREA SERVED:+/-314 FTSTAIR SEPARATION REQUIRED (FULLY SPRINKLER BLDG):≥+/-105 FT (+/-314/3)STAIR SEPARATION PROVIDE:+/-243 FTSTANDPIPE:REQUIRED PERIBC 406.5.8. ELECTRIC CHARGING REQUIREMENTS (WAC 51-50-0429.2):WHERE PARKING IS PROVIDED, TEN PERCENT OF PARKING SPACES SHALL BE PROVIDED WITH ELECTRIC VEHICLE CHARGING INFRASTRUCTURE IN COMPLIANCE WITH SECTIONS 427.3, 427.4 AND 427.5. WHEN THE CALCULATION OF PERCENT SERVED RESULTS IN A FRACTIONAL PARKING SPACE, THE APPLICANT SHALL ROUND UP TO THE NEXT WHOLE NUMBER.(STALLS IN PASSENGER LOADING/ UNLOADING ZONE, MOTORCYCLE PARKING AND DEDICATED SOUND TRANSIT MAINTENANCE TRUCK PARKING NOT INCLUDED IN THE ELECTRIC CHARGING REQUIREMENT CALCULATION)TOTAL STALLS W/ ELEC CHARGING INFRASTRUCTURE REQUIRED (PER WAC 51-50-0429.2) • 10% OF TOTAL PARKING (0 .1 X 724)73 STALLSTOTAL PARKING CAPACITY:724 CARS & 28 MOTORCYCLESSTANDARD STALLS W/ ELEC CHARGING:14 STALLSADA STALLS WITH ELEC CHARGING:2 STALLSTOTAL STALLS W/ ELEC CHARGING:16 STALLSSTANDARD STALLS W/ ELEC CHARGING INFRASTRUCTURE:81ADA STALLS W/ ELEC CHARGING INFRASTRUCTURE:5TOTAL STALLS WITH ELECTRIC CHARGING INFRASTRUCTURE PROVIDED: • 16+81+5= 102ADA PARKING REQUIREMENT ( RMC 4-4-080):2% OF TOTAL SPACESTOTAL PARKING STALL:724REQUIRED ADA STALL:15 ADA STALL PROVIDED:15ELEC VEHICLE CHARGING ADA STALL REQUIRED (PER WAC 51-50-0429.5) • 10% OF TOTAL ADA STALL (0.1X15):2 STALLSELECTRIC VEHICLE CHARGING ADA STALL PROVIDED:7 STALLSVAN PARKING SPACES (2010 ADA STANDARD 208.2.4)FOR EVERY SIX OR FRACTION OF SIX PARKING SPACES REQUIRED PROVIDE ONE VAN PARKING SPACE.TOTAL ADA STALL PROVIDED:15TOTAL VAN SPACE REQUIRED:3VAN SPACE PROVIDED:3PASSENGER LOADING ZONES (2010 ADA STANDARDS 209.2.1)ACCESSIBLE PASSENGER LOADING STALL REQUIRED:1ACCESSIBLE PASSENGER LOADING STALL PROVIDED:1PARKING TYPESSTALL TYPE COUNTSTALL DIMENSIONWIDTH DEPTHPICK UP/ DROP OFF STALLS 9 9'-0" 20'-0"ADA PICK UP/ DROP OFF STALLS 1 9'-0" 20'-0"SOUND TRANSIT ONLY PARKING (NOTFOR GENERAL PUBLIC)2 9'-0" 20'-0"MOTORCYCLE STALLS 28 4'-0" 8'-0"STANDARD STALLS 614 8'-6" 18'-0"STANDARD STALLS W/ ELEC CHARGING 14 8'-6" 18'-0"STANDARD STALLS W/ ELEC CHARGINGINFRASTRUCTURE ONLY (NO CHARGER)81 8'-6" 18'-0"ADA STALLS8 8'-6" 18'-0"ADA STALLS W/ ELECTRIC CHARGING 2 8'-6" 18'-0"ADA STALLS W/ ELEC CHARGINGINFRASTRUCTURE ONLY (NO CHARGER)2 8'-6" 18'-0"ADA VAN STALLS W/ ELEC CHARGINGINFRASTRUCTURE ONLY (NO CHARGER)3 8'-6" 18'-0"BUILDING ENVELOPE REQUIREMENTS (IECC 2018)CLIMATE ZONE (IECC 2018 C301):4C (KING COUNTY)THERMAL ENVELOPE (IECC 2018 TABLE C402.1.3)• WALLS (ABOVE GRADE)• MASS:R-11.4ci• METAL FRAME:R-13 + R-7.5ci• FLOORS• MASS:R-10ci• SLAB-ON-GRADE FLOORS• UNHEATED SLABS:R-10 FOR 24 INCHES BELOWBUILDING ENVELOPE FENESTRATION MAX U-FACTOR ( IECC 2018 TABLE C402.4)• FIXED FENESTRATION:0.38• OPERABLE FENESTRATION:0.45PLUMBING FIXTURES (IBC 2902.1)RESTROOMS ARE NOT FOR GENERAL PUBLIC USE AND ARE FOR LIMITED SOUND TRANSIT PERSONNEL AND METRO BUS OPERATORS ONLY. THERE WILL BE 2 PERSONNEL IN THE SECURITY OFFICE IN THE GARAGE AND ABOUT 13 METRO BUS OPERATORS WHEN BUS LAYOVER STALLS ARE AT FULL CAPACITY. LAVATORIESWATER CLOSETS/ URINALSMALE FEMALEREQUIRED 1 1 1PROVIDED 2 2 2*** IN ADDITION TO THE MALE AND FEMALE RESTROOMS, ONE SINGLE OCCUPANCY GENDER NEUTRAL RESTROOM IS PROVIDED.LOCATION:750 RAINIER AVE S, RENTON, WA 98055PARCEL NUMBER:1923059035, 1923059063, 1923059068, 1923059074,LEGAL DESCRIPTION:FOR PARCEL No. 1923059035:LOT 2 LESS HWY PER DEED #20110812001717 OF RENTON LLA #LUA-02-025-LLA REC 20020515900009 LOCATED IN NW 1/4 OF NE 1/4FOR PARCEL No. 1923059063:POR OF NW QTR OF NE QTR STR 19-23-05 DAF: BEG AT NE COR SD SEC 19 TH N 89-50-24 W ALG N LN SD NE QTR 2179.38 FT TH S 00-09-36 W AT R/A TO SD N LN 510.35 FT TO TPOB TH CONTG S 00-09-36 W 260.0 FT TO NLY MGN OF BN RR R/W (FORMERLY NP RR R/W) TH N 77-20-05 E ALG SD MGN 414.00 FT TO ORIGINAL C/L OF BONNEVILLE POWER TRANSMISSION LINE R/W TH N 00-29-24 W ALG SD C/L 168.13 FT TO PT FROM WCH TPOB BEARS N 89-50-24 W TH N 89-50-24 W TO TPOB LESS W 0.98 FT THOFFOR PARCEL No. 1923059068:POR OF ABANDONED BN RR R/W (FORMERLY NP RR) LY WLY OF FOLG DESC LN: BEG AT NXN OF ORIGINAL C/L OF BONNEVILLE POWER TRANSMISSION LINE R/W WITH N LN OF NE QTR STR 19-23-05 SD PT BEING 1783.40 FT W OF NE COR SD SEC 19 LESS HWY PER DEED #20110812001717FOR PARCEL No. 1923059074:POR OF PUGET SOUND POWER & LIGHT CO R/W IN NE QTR STR 19-23-05 LY NORTH OF NLY MGN OF S GRADY WAY & WLY OF FOLG DESC LN -BEG AT NXN OF ORIGINAL C/L OF BONNEVILLE POWER TRANSMISSION LINE R/W SD PT BEING 1783.40 FT W OF NE COR SD SEC 19 TH S 00-29-24 W ALG SD C/L TO NLY LN SD S GRADY WAY LESS POR LY WLY OF ELY LN OF RAINIER AVE S (STATE RD NO 167) & LESS POR CONDEMNED BY STATE OF WASHINGTON IN SCC NO 861445 LESS HWY PER DEED #20110812001717AUTHORITY HAVING JURISDICTION:CITY OF RENTONZONING AND LAND USEZONING DISTRICTCOMMERCIAL ARTERIAL (CA) LAND USE DESIGNATION:MIXED USE (CMU)OVERLY DISTRICT:URBAN DESIGN DISTRICT DDEVELOPMENT STANDARDS:RENTON MUNICIPAL CODE ( RMC) TITLEIV -DEVELOPMENT REGULATIONSALLOWABLE BLDG HT:65 FT (50FT + 15 FT) THE 15FT INCREASE IS ALLOWED FOR BUILDING WITH PITCH ROOF FOR 60% OR MORE OF THE STRUCTURE. GIVEN THE FUNCTION OF THE GARAGE, THE INTENT IS TO MEET THE INTENT OF THE CODE THROUGH FACADE DESIGN AND ARTICULATION. THIS WAS CONFIRMED IN A MEETING WITH THE CITY OF RENTON HELD ON 03/25/2021 1:00PM-2:00PM. MAX BUILDING HEIGHT PROVIDED:64'-1 1/2"BUILDING CODE INFORMATIONBUILDING CODES:- INTERNATIONAL BUILDING CODE (IBC) 2018- INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2018- INTERNATIONAL FIRE CODE(IFC 2018)- RENTON MUNICIPAL CODE (RMC)- WASHINGTON ADMINISTRATIVE CODE (WAC) 51-50WASHINGTON'S BUILDING CODE AMENDMENTS - ADA ACCESSIBILITY GUIDELINES(ADAAG) FOR BUILDINGS AND FACILITIES- 2010 ADA STANDARDSFOR ACCESSIBLE DESIGN- NFPA 702020: NATIONAL ELECTRICAL CODE WASHINGTON CITIES ELECTRICAL CODE, 2020- NFPA 132019: STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMSPROPOSED USE:OPEN PARKING GARAGE IBC 406.5.2 OPENINGS: FOR NATURAL VENTILATION PURPOSES, THE EXTERIOR SIDE OF THE STRUCTURE SHALL HAVE UNIFORMLY DISTRIBUTED OPENINGS ON TWO OR MORE SIDES. THE AREA OF SUCH OPENING IN EXTERIOR WALLS ON A TIER SHALL BE NOT LESS THAN 20% OF THE TOTAL PERIMETER WALL AREA OF EACH TIER. THE AGGREGATE LENGTH OF THE OPENINGS CONSIDERED TO BE PROVIDING NATURAL VENTILATION SHALL BE NOT LESS THAN 40% OF THE PERIMETER OF THE TIER. INTERIOR WALL SHALL BE NOT LESS THAN 20% OPEN WITH UNIFORMLY DISTRIBUTED OPENINGS. OCCUPANCY GROUPS:S-2, LOW HAZARD STORAGE, B BUSINESS (THEB OCCUPANCY IS ACCESSORY OCCUPANCY)CONSTRUCTION TYPE:TYPE IIBFIRE PROTECTION:FULLY SPRINKLEREDFIRE ALARM:REQUIRED (RMC 4-5-70, 90.907.2.24) AD11.62345678910111213CB± 33'± 116'± 157'± 59'± 142'± 103'± 27'± 32'UP TO LEVEL 2 STAIR #1TO LEVEL 1 EXIT± 144'STAIR #1STAIR #2BTP120113BTP120112BTP120110BTP120106BTP120104BTP120105BTP120108BTP120107BTP120109BTP120101ELEVATOR #2ELEVATOR #1BTP120102BTP120103BTP120111DIAGONAL DISTANCE = +/-314 FTSTAIR SEPERATION REQUIRED: +/-314 FT/3 = +/-105 FTEXIT REQ.:No.OCCP X 0.2 OR 32 INCHES83 X 0.2 = 17 INCHES < 32 INCHESEXIT REQ.:32 INCHESEXIT PROVIDED:72 INCHESEXIT REQ.:No.OCCP X 0.2 OR 32 INCHES83 X 0.2 = 17 INCHES < 32 INCHESEXIT REQ.:32 INCHESEXIT PROVIDED:72 INCHESEXIT REQ.:No.OCCP X 0.2 OR 32 INCHES83 X 0.2 = 17 INCHES < 32 INCHESEXIT REQ.:32 INCHESEXIT PROVIDED:36 INCHES± 73'STAIR SEPARATION = +/- 240 FT± 20'AD11.62345678910111213CB± 56'± 60'STAIR WIDTH REQ.:No.OCCP X 0.3 OR 36 INCHES125 X 0.3 = 38 INCHES > 36 INCHESSTAIR WIDTH REQ.:38 INCHESSTAIR WIDTH PROVIDED:72 INCHESSTAIR WIDTH REQ.:No.OCCP X 0.3 OR 36 INCHES125 X 0.3 = 38 INCHES > 36 INCHESSTAIR WIDTH REQ.:38 INCHESSTAIR WIDTH PROVIDED:72 INCHESUP TO LEVEL 3 STAIR #1DIAGONAL DISTANCE = +/-314 FTSTAIR SEPERATION REQUIRED: +/-314 FT/3 = +/-105 FT STAIR SEPARATION = +/- 250 FTDN TO LEVEL 2.5 STAIR #2BTP120203BTP120201BTP120202± 100'± 100'± 116'± 100'± 100'ELEVATOR #2ELEVATOR #1STAIR #1± 100'± 24'± 16'± 26'± 8'STAIR #2GENERAL NOTE:FOR GENERAL EGRESS REQUIREMENTS REFER TO BUILDING CODE INFORMATION SHEET.LEVEL 1 GARAGE STALL COUNT:EV READY:81STALLSEV:14STALLSPO/DO:9STALLSPO/DO ADA:1STALLSEV ADA:2STALLSEV READA ADA: 2STALLSVAN EV READY ADA: 3STALLSMOTORCYCLE: 28STALLSST ONLY: 2STALLSTOTAL CARS: 142STALLSLEGEND:PATH OF TRAVEL15' X STAIR WIDTH STAIR SURGE ZONE (SSZ)(10'X10') ELEVATOR SURGE ZONE (ESZ)+ 0'-0"DOOR EXIT CAPACITY-LEVEL 2 GARAGE STALL COUNT:STANDARD: 160 STALLSACCESSIBLE: 2 STALLSTOTAL CARS: 162 STALLSNNOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONAS NOTEDPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:23:19 PM405740BRT-405-AZP500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-AZP50102/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGARAGE EXITING PLAN - LEVEL 1 AND 2SOUTH RENTON TRANSIT CENTERSCALE: 1" = 30'-0"405-AZP501EXITING PLAN LEVEL 1 & 1.51SCALE: 1" = 30'-0"405-AZP501EXITING PLAN LEVEL 2 & 2.52SCALE: 1" = 30'-0"0303060EGRESS PATH TRAVEL DISTANCE LEVEL1 & 2LEVELMAX.EGRESSPATHLENGTHEGRESSCAPACITY INOCCUPANTSEGRESS COMPONENTPROVIDEDMIN DOORWIDTH ININCHESMIN STAIRWIDTH ININCHESLEVEL 1 392 FT 244 36" 72"LEVEL 2 256 FT 249 36" 72"LEVEL ONE ROOMS - EXITING PLANROOM NUMBER ROOM NAMEBTP120101 ELEVATOR MACHINE ROOMBTP120102 SECURITY ROOMBTP120103 LACTATION ROOMBTP120104 WOMEN'S RESTROOMBTP120105 ALL GENDER RESTROOMBTP120106 MEN'S RESTROOMBTP120107 JANITOR ROOMBTP120108 STORAGEBTP120109 COMMUNICATIONS ROOMBTP120110 SPRINKLER ROOMBTP120111 KING COUNTY PANELS ROOMBTP120112 ELECTRICAL ROOMBTP120113 GENERATOR ROOMLEVEL TWO ROOMS - EXITING PLANBTP120201 COMMUNICATIONS CLOSETBTP120202 ELECTRICAL CLOSETBTP120203 COMMUNICATIONS CLOSET AD11.62345678910111213CB STAIR SEPARATION = +/- 250 FT± 56'± 60'STAIR WIDTH REQ.:No.OCCP X 0.3 OR 36 INCHES125 X 0.3 = 38 INCHES > 36 INCHESSTAIR WIDTH REQ.:38 INCHESSTAIR WIDTH PROVIDED:72 INCHESSTAIR WIDTH REQ.:No.OCCP X 0.3 OR 36 INCHES125 X 0.3 = 38 INCHES > 36 INCHESSTAIR WIDTH REQ.:38 INCHESSTAIR WIDTH PROVIDED:72 INCHESUP TO LEVEL 4 STAIR #1DIAGONAL DISTANCE = +/-314 FTSTAIR SEPERATION REQUIRED: +/-314 FT/3 = +/-105 FTDN TO LEVEL 3.5 STAIR #2± 100'± 100'± 116'± 100'± 100'± 100'± 24'± 16'± 26'± 10'ELEVATOR #2ELEVATOR #1STAIR #1STAIR #2AD11.62345678910111213CB STAIR SEPARATION = +/- 250 FTSTAIR WIDTH REQ.:No.OCCP X 0.3 OR 36 INCHES125 X 0.3 = 38 INCHES > 36 INCHESSTAIR WIDTH REQ.:38 INCHESSTAIR WIDTH PROVIDED:72 INCHESSTAIR WIDTH REQ.:No.OCCP X 0.3 OR 36 INCHES125 X 0.3 = 38 INCHES > 36 INCHESSTAIR WIDTH REQ.:38 INCHESSTAIR WIDTH PROVIDED:72 INCHESUP TO LEVEL 5 STAIR #1DIAGONAL DISTANCE = +/-314 FTSTAIR SEPERATION REQUIRED: +/-314 FT/3 = +/-105 FTDN TO LEVEL 4.5 STAIR #2± 56'± 60'± 100'± 100'± 116'± 100'± 100'± 100'± 24'± 16'± 26'± 10'STAIR #1ELEVATOR #1ELEVATOR #2STAIR #2BTP120401BTP120402BTP120403LEVEL 3 GARAGE STALL COUNT:STANDARD: 160 STALLSACCESSIBLE: 2 STALLSTOTAL: 162 STALLSLEVEL 4 GARAGE STALL COUNT:STANDARD: 160 STALLSACCESSIBLE: 2 STALLSTOTAL CARS: 162 STALLSGENERAL NOTE:FOR GENERAL EGRESS REQUIREMENTS REFER TO BUILDING CODE INFORMATION SHEET.LEGEND:PATH OF TRAVEL15' X STAIR WIDTH STAIR SURGE ZONE (SSZ)(10'X10') ELEVATOR SURGE ZONE (ESZ)+ 0'-0"DOOR EXIT CAPACITY-NNOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONAS NOTEDPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:23:24 PM405750BRT-405-AZP500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-AZP50202/11/2022R. GORMANF. ReviewedPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGARAGE EXITING PLAN - LEVEL 3 AND 4SOUTH RENTON TRANSIT CENTERSCALE: 1" = 30'-0"405-AZP502EXITING PLAN LEVEL 3 & 3.51SCALE: 1" = 30'-0"405-AZP502EXITING PLAN LEVEL 4 & 4.52SCALE: 1" = 30'-0"0303060EGRESS PATH TRAVEL DISTANCE LEVEL 3 & 4LEVELMAX.EGRESSPATHLENGTHEGRESSCAPACITY INOCCUPANTSEGRESS COMPONENTPROVIDEDMIN DOORWIDTH ININCHESMIN STAIRWIDTH ININCHESLEVEL 3 256 FT 248 36" 72"LEVEL 4 256 FT 249 36" 72"LEVEL FOUR ROOMS - EXITING PLANBTP120401 COMMUNICATIONS CLOSETBTP120402 ELECTRICAL CLOSETBTP120403 COMMUNICATIONS CLOSET AD11.62345678910111213CB STAIR SEPARATION = +/- 250 FTSTAIR WIDTH REQ.:No.OCCP X 0.3 OR 36 INCHES125 X 0.3 = 38 INCHES > 36 INCHESSTAIR WIDTH REQ.:38 INCHESSTAIR WIDTH PROVIDED:72 INCHESSTAIR WIDTH REQ.:No.OCCP X 0.3 OR 36 INCHES125 X 0.3 = 38 INCHES > 36 INCHESSTAIR WIDTH REQ.:38 INCHESSTAIR WIDTH PROVIDED:72 INCHESDIAGONAL DISTANCE = +/-314 FTSTAIR SEPERATION REQUIRED: +/-314 FT/3 = +/-105 FTELEVATOR #1ELEVATOR #2STAIR #2STAIR #1± 56'± 60'± 100'± 100'± 60'± 100'± 100'± 61'± 24'± 16'± 26'± 10'FROM BELOW LEVEL TO LEVEL 5 STAIR #2± 56'LEVEL 5 GARAGE STALL COUNT:STANDARD: 134 STALLSACCESSIBLE: 2 STALLSTOTAL CARS: 136 STALLSGENERAL NOTE:FOR GENERAL EGRESS REQUIREMENTS REFER TO BUILDING CODE INFORMATION SHEET.LEGEND:PATH OF TRAVEL15' X STAIR WIDTH STAIR SURGE ZONE (SSZ)(10'X10') ELEVATOR SURGE ZONE (ESZ)+ 0'-0"DOOR EXIT CAPACITY-NNOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONAS NOTEDPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:23:26 PM405760BRT-405-AZP500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-AZP50302/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGARAGE EXITING PLAN - LEVEL 5SOUTH RENTON TRANSIT CENTERSCALE: 1" = 30'-0"405-AZP503EXITING PLAN LEVEL 5 & 5.51SCALE: 1" = 30'-0"0303060EGRESS PATH TRAVEL DISTANCE LEVEL 5LEVELMAX.EGRESSPATHLENGTHEGRESSCAPACITY INOCCUPANTSEGRESS COMPONENTPROVIDEDMIN DOORWIDTH ININCHESMIN STAIRWIDTH ININCHESLEVEL 5 256 FT 248 36" 72" 12345678910111213KEY NOTES:1. GARAGE POINT OF ENTRY (AT GRADE LEVEL).2. 5 TIER PARKING GARAGE.3. CANOPY.4. BIKE RACK.5. OPTIONAL FUTURE PV PANEL.6. STATION PLATFORM AREA.7. BUS LAY-OVER AREA.8. DUMPSTER ENCLOSURE.9. UTILITY YARD.10. GARAGE DRIVE.11. FIRE DEPARTMENT ACCESSRAINER AVE SBUS BAYBUS BAY1123474S GRADY WAY665891010POTENTIAL FUTURE TRANSIT ORIENTED DEVELOPMENT (TOD)511111111RENTON FM. BUILDING IS FULLY SPRINKLERED)225' - 0" (INCREASE ALLOWED BY CITY OFRENTON FM. BUILDING IS FULLY SPRINKLERED)225' - 0" (INCREASE ALLOWED BY CITY OFEXTENT OF SEATTLE CITY LIGHT OVERHEAD POWERLINE EASEMENTSITE PLAN LEGENDEXTENT OF 20 FT OFFSET FROM PROPERTYGRASS LAWN, SEE LANDSCAPE DRAWINGSLOW LAWN, SEE LANDSCAPE DRAWINGSBIORETENTION PLANTINGS, SEE LANDSCAPE DRAWINGSDECIDUOUS/ACCENT TREES, SEE LANDSCAPE DRAWINGSCONIFER TREES, SEE LANDSCAPE DRAWINGSDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONAS NOTEDPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:23:13 PM405770BRT-405-ASP500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-ASP50202/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGARAGE SITE PLANSOUTH RENTON TRANSIT CENTERSCALE: 1" = 50'-0"05050100NSCALE: 1" = 50'-0"405-ASP502ARCHITECTURAL SITE PLAN1 UPA405-AEE501B405-AEE502A405-AEE502B405-AEE501A405-AEX501B405-AEX501ADBTP120105BTP120104ELEV#2ELEV#111.62345678910111213BTP120106UPUP4.5%4.5%BTP120101BTP120109BTP1201071BTP120102BTP120103182' - 0"UP TO LEVEL 1.518' - 0"23' - 0"18' - 0"UP TO LEVEL 218' - 0"23' - 0"18' - 0"20' - 0"23' - 0"18' - 0"18' - 0"25' - 6"18' - 0"27' - 9"1344225671405-APP5061405-APP5071405-APP508BTP120108BTP120110BTP120111BTP120112BTP1201132405-APP508CB81091012' - 0"8' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"8' - 0"12' - 0"1' - 4 1/2"23' - 3"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"2' - 10"20' - 0"2' - 8"3' - 6"23' - 3"1' - 4 1/2"60' - 9"60' - 6"60' - 9"3' - 6"26' - 0"3' - 6"12' - 6"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"13' - 0"3' - 6"25' - 6"2' - 10"13' - 9 1/2"1' - 4 1/2"12' - 0"STR#1STR#23' - 6"26' - 0"3' - 6"12' - 6"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"12' - 6"3' - 6"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"269' - 6"111114' - 6"19' - 3"19' - 3"14' - 6"13' - 9 1/2"1' - 4 1/2"2' - 10"26' - 0"KEY NOTES (THIS SHEET):1. GARAGE POINT OF ENTRY.2. CURTAIN WALL SYSTEM.3. BOLLARD, TYP.4. LINE OF CANOPY ABOVE.5. CONCRETE VEHICLE BARRIER, TYP.6. CABLE BARRIER, TYP.7. CONCRETE COLUMN, TYP SEE STRUCT.8. TYPICAL DIRECTIONAL ARROW STRIPING9. TYPICAL ACCESSIBLE AISLE STRIPING10. TYPICAL DIAGONAL STRIPING (NO PARKING ZONE).11. METAL CANE DETECTION RAILINGLEVEL 1 GARAGE STALL COUNT:EV READY:81STALLSEV:14STALLSPO/DO:9STALLSPO/DO ADA:1STALLSEV ADA:2STALLSEV READA ADA: 2STALLSVAN EV READY ADA: 3STALLSMOTORCYCLE: 28STALLSST ONLY: 2STALLSTOTAL CARS: 142STALLSNOTE:FOR WALL TYPES LEGEND REFER TO ENLARGED PLANS.NNOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONAS NOTEDPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:22:38 PM405780BRT-405-APP500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-APP50102/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGARAGE FLOOR PLAN - LEVEL 1SOUTH RENTON TRANSIT CENTERSCALE: 1/16" = 1'-0"405-APP501GARAGE FLOOR PLAN LEVEL 1 & 1.51SCALE: 1/16" = 1'-0"0161632PARKING TYPES - LEVEL ONEPARKING TYPE DESIGNATIONSTALLDIMENSIONMINACCESSAISLEREQUIREDWIDTH DEPTHPICK-UP/ DROP-OFF STALL PU/DO 9'-0" 20'-0" N/AADA PICK-UP/ DROP-OFFSTALLADA PU/DO 9'-0" 20'-0" 60 INCHESADA STALL W/ ELECCHARGINGADA; EV 8'-6" 18'-0" 60 INCHESADA STALL W/ ELECCHARGING INFRASTRUCTUREONLYADA; EVREADY8'-6" 18'-0" 60 INCHESADA VAN STALL W/ CHARINGINFRASTRUCTURE ONLYADA VAN; EVREADY8'-6" 18'-0" 96 INCHESSTANDARD STALL W/ ELECCHARGINGEV 8'-6" 18'-0" N/ASTANDARD STALL W/ ELECCHARGING INFRASTRUCTUREONLYEV READY 8'-6" 18'-0" N/AMOTORCYCLE STALL MC 4'-0" 8'-0" N/ASOUND TRANSIT DEDICATEDSTALLST ONLY 9'-0" 20'-0" N/ALEVEL ONE ROOM SCHEDULEROOM NUMBER ROOM NAME AREABTP120101 ELEVATOR MACHINE ROOM 359 SFBTP120102 SECURITY ROOM 131 SFBTP120103 LACTATION ROOM 76 SFBTP120104 WOMEN'S RESTROOM 169 SFBTP120105 ALL GENDER RESTROOM 41 SFBTP120106 MEN'S RESTROOM 163 SFBTP120107 JANITOR ROOM 144 SFBTP120108 STORAGE 394 SFBTP120109 COMMUNICATIONS ROOM 335 SFBTP120110 SPRINKLER ROOM 223 SFBTP120111 KING COUNTY PANELS ROOM 40 SFBTP120112 ELECTRICAL ROOM 437 SFBTP120113 GENERATOR ROOM 370 SF UPA405-AEE501B405-AEE502A405-AEE502B405-AEE501A405-AEX501B405-AEX501AD11.62345678910111213269' - 6"ELEV#2ELEV#1BTP120202BTP120201BTP1202039935522467119108UP4.2%UP4.2%18' - 0"23' - 0"18' - 0"18' - 0"23' - 4"18' - 0"18' - 0"23' - 0"18' - 0"18' - 0"26' - 6"26' - 6"18' - 0"24' - 6"24' - 6"CB1211STR#2STR#112' - 0"8' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"8' - 0"12' - 0"1' - 4 1/2"23' - 3"3' - 6"22' - 0"60' - 9"60' - 6"60' - 9"3' - 6"26' - 0"3' - 6"12' - 6"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"13' - 0"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"182' - 0"UP TO LEVEL 3DOWN TO LEVEL 1.5UP TO LEVEL 2.5UP TO LEVEL 2.522' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"2' - 10"22' - 0"22' - 0"20' - 0"2' - 8"3' - 6"23' - 3"1' - 4 1/2"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"19' - 3"22' - 0"3' - 6"22' - 0"3' - 6"3' - 6"25' - 6"2' - 10"13' - 9 1/2"1' - 4 1/2"12' - 0"3' - 6"14' - 6"19' - 3"3' - 6"22' - 0"3' - 6"3' - 6"13' - 9 1/2"1' - 4 1/2"26' - 0"3' - 6"12' - 6"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"16' - 8"2' - 10"14' - 6"3' - 6"26' - 0"3' - 6"12' - 6"KEY NOTES (THIS SHEET):1. BARRIER BEAM AND SIGNAGE BELOW.2. CURTAIN WALL SYSTEM.3. PARKING STALL BELOW; TYP4. BOLLARD, TYP.5. GLAZED CANOPY BELOW, TYP.6. CONCRETE VEHICLE BARRIER, TYP.7. CABLE BARRIER, TYP.8. CONCRETE COLUMN, TYP SEE STRUCT.9. GARAGE SCREENING.10. TYPICAL DIRECTIONAL ARROW STRIPING.11. TYPICAL ACCESSIBLE AISLE STRIPING.12. TYPICAL DIAGONAL STRIPING (NO PARKING ZONE).LEVEL 2 GARAGE STALL COUNT:STANDARD: 160 STALLSACCESSIBLE: 2 STALLSTOTAL CARS: 162 STALLS20 GA 3 5/8" MTL STUD @ 16 OC WITH 5/8" CEMENTITIOUS BACKER BOARD & FULL HEIGHT TILE FINISH ON ONE SIDE. PROVIDE BATT INSULATION IN CAVITY.20 GA 3 5/8" MTL STUD @ 16 OC WITH 5/8" CEMENTITIOUS BACKER BOARD & FULL HEIGHT TILE FINISH ON BOTH SIDES. PROVIDE BATT INSULATION IN CAVITY20 GA 8" MTL STUD @ 16 OC WITH 5/8" CEMENTITIOUS BACKER BOARD & FULL HEIGHT TILE FINISH ON BOTH SIDES. PROVIDE BATT INSULATION IN CAVITYWALL TYPES20 GA 3 5/8" MTL STUD @ 16 OC WITH 5/8" GYPSUM WALL BOARD ON BOTH SIDES. PROVIDE BATT INSULATION IN CAVITYFULLY GROUTED NOM 8" CMU WALL. FOR ADDITIONAL INFORMATION REFER TO STRUCTURAL.FULLY GROUTED NOM 8" CMU WALL WITH MIN R-11.4 CONTINUOUS RIGID INSULATION & 20 GA 2 1/2" MTL STUD FURRING @ 16 OC & 5/8" GYPSUM WALL BOARD FINISH. FOR ADDITIONAL INFORMATION REFER TO STRUCTURAL.20 GA 8" MTL STUD @ 16 OC WITH MIN R-13 BATT INSULATION IN CAVITY AND 5/8" GYPSUM WALL BOARD FINISH ON INTERIOR INSIDE. PROVIDE 5/8" GYPSUM BASE SHEATHING, AIR/ WATER BARRIER MEMBRANE, MIN R-7.5 CONTINUOUS RIGID INSULATION, 7/8" MTL FURRING CHANNELS AT 24" OC HORIZONTALLY AND 1 1/2" MTL PANELS ON THE EXTERIOR SIDE. FULLY GROUTED NOM 8" CMU WALL WITH MIN R-11.4 CONTINUOUS RIGID INSULATION & 20 GA 2 1/2" MTL STUD FURRING @ 16 OC & 5/8" CEMENTITOUS BACKER BOARD w/ FULL HEIGHT TILE FINISH. FOR ADDITIONAL INFORMATION REFER TO STRUCTURAL.R-11.4 CONTINUOUS RIGID INSULATION & 20 GA 2 1/2" MTL STUD FURRING @ 16 OC & 5/8" GYPSUM WALL BOARD FINISHNNOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONAS NOTEDPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:22:42 PM405790BRT-405-APP500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-APP50202/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGARAGE FLOOR PLAN - LEVEL 2SOUTH RENTON TRANSIT CENTERSCALE: 1/16" = 1'-0"405-APP502GARAGE FLOOR PLAN LEVEL 2 & 2.51SCALE: 1/16" = 1'-0"0161632PARKING TYPES - LEVEL TWOPARKING TYPE DESIGNATIONSTALLDIMENSIONMINACCESSAISLEREQUIREDWIDTH DEPTHADA STALL ADA 8'-6" 18'-0" 60 INCHESSTANDARD STALL N/A 8'-6" 18'-0" N/ALEVEL TWO ROOM SCHEDULEROOM NUMBER ROOM NAME AREABTP120201 COMMUNICATIONS CLOSET 123 SFBTP120202 ELECTRICAL CLOSET 124 SFBTP120203 COMMUNICATIONS CLOSET 123 SF DNUPA405-AEE501B405-AEE502A405-AEE502B405-AEE501A405-AEX501B405-AEX501AD11.62345678910111213ELEV#2ELEV#1772781134576UP4.2%UP4.2%18' - 0"23' - 0"18' - 0"18' - 0"23' - 4"18' - 0"18' - 0"23' - 0"18' - 0"26' - 6"18' - 0"18' - 0"26' - 6"24' - 6"18' - 0"24' - 6"CBSTR#1STR#2910269' - 6"12' - 0"8' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"8' - 0"12' - 0"1' - 4 1/2"23' - 3"3' - 6"22' - 0"60' - 9"60' - 6"60' - 9"14' - 6"3' - 6"26' - 0"3' - 6"12' - 6"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"13' - 0"3' - 6"25' - 6"2' - 10"13' - 9 1/2"1' - 4 1/2"12' - 0"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"182' - 0"UP TO LEVEL 4DOWN TO LEVEL 2.5UP TO LEVEL 3.5UP TO LEVEL 3.523' - 3"22' - 0"3' - 6"22' - 0"2' - 10"20' - 0"22' - 0"3' - 6"22' - 0"3' - 6"2' - 8"3' - 6"1' - 4 1/2"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"19' - 3"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"13' - 9 1/2"1' - 4 1/2"2' - 10"26' - 0"3' - 6"12' - 6"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"12' - 6"3' - 6"26' - 0"3' - 6"14' - 6"19' - 3"3' - 6"22' - 0"3' - 6"LEVEL 3 GARAGE STALL COUNT:STANDARD: 160 STALLSACCESSIBLE: 2 STALLSTOTAL: 162 STALLSKEY NOTES (THIS SHEET):1. CURTAIN WALL SYSTEM.2. PARKING STALL BELOW; TYP.3. BOLLARD, TYP.4. CONCRETE VEHICLE BARRIER, TYP.5. CABLE BARRIER, TYP.6. CONCRETE COLUMN, TYP SEE STRUCT.7. GARAGE SCREENING.8. TYPICAL DIRECTIONAL ARROW STRIPING.9. TYPICAL ACCESSIBLE AISLE STRIPING.10. TYPICAL DIAGONAL STRIPING (NO PARKING ZONE).NNOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONAS NOTEDPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:22:45 PM405800BRT-405-APP500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-APP50302/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGARAGE FLOOR PLAN - LEVEL 3SOUTH RENTON TRANSIT CENTERSCALE: 1/16" = 1'-0"405-APP503GARAGE FLOOR PLAN LEVEL 3 & 3.51SCALE: 1/16" = 1'-0"0161632PARKING TYPES - LEVEL THREEPARKING TYPE DESIGNATIONSTALLDIMENSIONMINACCESSAISLEREQUIREDWIDTH DEPTHADA STALL ADA 8'-6" 18'-0" 60 INCHESSTANDARD STALL N/A 8'-6" 18'-0" N/A UPA405-AEE501B405-AEE502A405-AEE502B405-AEE501A405-AEX501B405-AEX501AD11.62345678910111213ELEV#2ELEV#1BTP120402BTP120401BTP120403UP4.2%UP4.2%18' - 0"23' - 0"18' - 0"18' - 0"23' - 4"18' - 0"18' - 0"23' - 0"18' - 0"24' - 6"24' - 6"26' - 6"18' - 0"18' - 0"26' - 6"772781134576CBSTR#2STR#1269' - 6"12' - 0"8' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"8' - 0"12' - 0"1' - 4 1/2"23' - 3"3' - 6"22' - 0"60' - 9"60' - 6"60' - 9"14' - 6"3' - 6"26' - 0"3' - 6"12' - 6"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"13' - 0"3' - 6"25' - 6"2' - 10"13' - 9 1/2"1' - 4 1/2"12' - 0"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"109182' - 0"UP TO LEVEL 5DOWN TO LEVEL 3.5UP TO LEVEL 4.5UP TO LEVEL 4.53' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"2' - 10"20' - 0"2' - 8"3' - 6"23' - 3"1' - 4 1/2"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"19' - 3"22' - 0"3' - 6"22' - 0"13' - 9 1/2"1' - 4 1/2"19' - 3"3' - 6"22' - 0"3' - 6"2' - 10"26' - 0"3' - 6"12' - 6"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"12' - 6"3' - 6"26' - 0"3' - 6"14' - 6"KEY NOTES (THIS SHEET):1. CURTAIN WALL SYSTEM.2. PARKING STALL BELOW, TYP.3. BOLLARD, TYP.4. CONCRETE VEHICLE BARRIER, TYP.5. CABLE BARRIER, TYP.6. CONCRETE COLUMN, TYP SEE STRUCT.7. GARAGE SCREENING.8. TYPICAL DIRECTIONAL ARROW STRIPING.9. TYPICAL ACCESSIBLE AISLE STRIPING.10. TYPICAL DIAGONAL STRIPING ( NO PARKING ZONE).LEVEL 4 GARAGE STALL COUNT:STANDARD: 160 STALLSACCESSIBLE: 2 STALLSTOTAL CARS: 162 STALLS20 GA 3 5/8" MTL STUD @ 16 OC WITH 5/8" CEMENTITIOUS BACKER BOARD & FULL HEIGHT TILE FINISH ON ONE SIDE. PROVIDE BATT INSULATION IN CAVITY.20 GA 3 5/8" MTL STUD @ 16 OC WITH 5/8" CEMENTITIOUS BACKER BOARD & FULL HEIGHT TILE FINISH ON BOTH SIDES. PROVIDE BATT INSULATION IN CAVITY20 GA 8" MTL STUD @ 16 OC WITH 5/8" CEMENTITIOUS BACKER BOARD & FULL HEIGHT TILE FINISH ON BOTH SIDES. PROVIDE BATT INSULATION IN CAVITYWALL TYPES20 GA 3 5/8" MTL STUD @ 16 OC WITH 5/8" GYPSUM WALL BOARD ON BOTH SIDES. PROVIDE BATT INSULATION IN CAVITYFULLY GROUTED NOM 8" CMU WALL. FOR ADDITIONAL INFORMATION REFER TO STRUCTURAL.FULLY GROUTED NOM 8" CMU WALL WITH MIN R-11.4 CONTINUOUS RIGID INSULATION & 20 GA 2 1/2" MTL STUD FURRING @ 16 OC & 5/8" GYPSUM WALL BOARD FINISH. FOR ADDITIONAL INFORMATION REFER TO STRUCTURAL.20 GA 8" MTL STUD @ 16 OC WITH MIN R-13 BATT INSULATION IN CAVITY AND 5/8" GYPSUM WALL BOARD FINISH ON INTERIOR INSIDE. PROVIDE 5/8" GYPSUM BASE SHEATHING, AIR/ WATER BARRIER MEMBRANE, MIN R-7.5 CONTINUOUS RIGID INSULATION, 7/8" MTL FURRING CHANNELS AT 24" OC HORIZONTALLY AND 1 1/2" MTL PANELS ON THE EXTERIOR SIDE. FULLY GROUTED NOM 8" CMU WALL WITH MIN R-11.4 CONTINUOUS RIGID INSULATION & 20 GA 2 1/2" MTL STUD FURRING @ 16 OC & 5/8" CEMENTITOUS BACKER BOARD w/ FULL HEIGHT TILE FINISH. FOR ADDITIONAL INFORMATION REFER TO STRUCTURAL.R-11.4 CONTINUOUS RIGID INSULATION & 20 GA 2 1/2" MTL STUD FURRING @ 16 OC & 5/8" GYPSUM WALL BOARD FINISHNNOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONAS NOTEDPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:22:48 PM405810BRT-405-APP500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-APP50402/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGARAGE FLOOR PLAN - LEVEL 4SOUTH RENTON TRANSIT CENTERSCALE: 1/16" = 1'-0"405-APP504GARAGE FLOOR PLAN LEVEL 4 & 4.51SCALE: 1/16" = 1'-0"0161632PARKING TYPES - LEVEL FOURPARKING TYPE DESIGNATIONSTALLDIMENSIONMINACCESSAISLEREQUIREDWIDTH DEPTHADA STALL ADA 8'-6" 18'-0" 60 INCHESSTANDARD STALL N/A 8'-6" 18'-0" N/ALEVEL FOUR ROOM SCHEDULEROOM NUMBER ROOM NAME AREABTP120401 COMMUNICATIONS CLOSET 123 SFBTP120402 ELECTRICAL CLOSET 124 SFBTP120403 COMMUNICATIONS CLOSET 123 SF DNA405-AEE501B405-AEE502A405-AEE502B405-AEE501A405-AEX501B405-AEX501AD11.62345678910111213ELEV#2ELEV#1UP4.2%UP4.2%18' - 0"23' - 0"18' - 0"18' - 0"23' - 8"18' - 0"18' - 0"23' - 0"18' - 0"24' - 6"24' - 6"26' - 6"18' - 0"18' - 0"26' - 6"772781134576CBSTR#1STR#2910269' - 6"12' - 0"8' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"8' - 0"12' - 0"60' - 9"60' - 6"60' - 9"14' - 6"3' - 6"26' - 0"3' - 6"12' - 6"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"13' - 0"3' - 6"25' - 6"2' - 10"13' - 9 1/2"1' - 4 1/2"12' - 0"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"19' - 3"182' - 0"DOWN TO LEVEL 4.5UP TO LEVEL 5.5UP TO LEVEL 5.51' - 4 1/2"23' - 3"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"3' - 6"22' - 0"2' - 10"20' - 0"2' - 8"3' - 6"23' - 3"1' - 4 1/2"13' - 9 1/2"1' - 4 1/2"2' - 10"26' - 0"3' - 6"12' - 6"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"16' - 8"3' - 6"12' - 6"3' - 6"26' - 0"3' - 6"14' - 6"19' - 3"3' - 6"22' - 0"3' - 6"LEVEL 5 GARAGE STALL COUNT:STANDARD: 134 STALLSACCESSIBLE: 2 STALLSTOTAL CARS: 136 STALLSKEY NOTES (THIS SHEET):1. CURTAIN WALL SYSTEM.2. PARKING STALL BELOW; TYP3. BOLLARD, TYP.4. CONCRETE VEHICLE BARRIER, TYP.5. CABLE BARRIER, TYP.6. CONCRETE COLUMN, TYP SEE STRUCT.7. GARAGE SCREENING.8. TYPICAL DIRECTIONAL ARROW STRIPING.9. TYPICAL ACCESSIBLE AISLE STRIPING.10. TYPICAL DIAGONAL STRIPING (NO PARKING ZONE).NNOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONAS NOTEDPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:22:50 PM405820BRT-405-APP500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-APP50502/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGARAGE FLOOR PLAN - LEVEL 5SOUTH RENTON TRANSIT CENTERSCALE: 1/16" = 1'-0"405-APP505GARAGE FLOOR PLAN LEVEL 5 & 5.51SCALE: 1/16" = 1'-0"0161632PARKING TYPES - LEVEL FIVEPARKING TYPE DESIGNATIONSTALLDIMENSIONMINACCESSAISLEREQUIREDWIDTH DEPTHADA STALL ADA 8'-6" 18'-0" 60 INCHESSTANDARD STALL N/A 8'-6" 18'-0" N/A UPA10111213ALL GENDERRESTROOMBTP120105WOMEN'SRESTROOMBTP120104ELEVATOR #2ELEV#2MEN'SRESTROOMBTP120106ESZSSZSECURITYROOMBTP120102LACTATIONROOMBTP1201039671021131214192015171612ELEVATOR #1ELEV#118"18"CLR32"CLR32"1' - 9"HOISTWAY9' - 0" CLRHOISTWAY9' - 0" CLR5' - 1"ESZHOISTWAY11' - 4" CLR18"18"CLR60"EQEQ11111125' - 6"8' - 0"12' - 0"47' - 4"1' - 0"6' - 3"10' - 8"6' - 8"13' - 6"5' - 9 5/8"7' - 8 3/4"5' - 5 5/8"11 THREADS @ 11" EA.10' - 1"LANDING6' - 0"STAIR #1STR#13 1/2"4' - 4 1/2"6"6' - 0"6' - 0"1' - 0"UP1' - 0"16' - 1"CLCLCLCLCL1' - 0"122518813223CLR49"36" TYPALIGN25' - 4"1' - 4"1' - 4"CLR12"CLR12"5' - 8"1' - 8"8' - 10"1' - 2"36" TYPCLR3' - 9"CLR4' - 1 3/4"2' - 0"8' - 8"5' - 4"2' - 4"2' - 0"2232324KEY NOTES (THIS SHEET):1. CONCRETE FLOOR, SEE STRUCT.2. CURTAIN WALL SYSTEM.3. REQUIRED ADA WATER CLOSET CLEAR SPACE.4. BOLLARD, TYP.5. CONCRETE COLUMN, TYP SEE STRUCT.6. TICKET WINDOW.7. P-LAM COUNTER.8. SINK.9. PRIVACY CURTAIN.10. P-LAM BASE CABINET BELOW.11. RESTROOM IDENTIFICATION DOOR SIGN.12. TYPICAL LAVATORY.13. SOLID SURFACE COUNTER.14. URINAL, SEE PLUMBING.15. TYPICAL WATER CLOSET, SEE PLUMBING.16. TYPICAL 36" GRAB BAR.17. TYPICAL 42" GRAB BAR.18. TYPICAL SEAT COVER DISPENSER.19. TYPICAL TOILET TISSUE DISPENSER.20. TYPICAL NAPKIN DISPOSAL.21. TYPICAL PAPER TOWEL DISPENSER.22. PERFORATED METAL PANEL RAILING.23. THERMALLY BROKEN ALUMINUM WINDOW24. METAL CANE DETECTION RAILINGLEGEND:15' X STAIR WIDTH STAIR SURGE ZONE (SSZ)(10'X10') ELEVATOR SURGE ZONE (ESZ)20 GA 3 5/8" MTL STUD @ 16 OC WITH 5/8" CEMENTITIOUS BACKER BOARD & FULL HEIGHT TILE FINISH ON ONE SIDE. PROVIDE BATT INSULATION IN CAVITY.20 GA 3 5/8" MTL STUD @ 16 OC WITH 5/8" CEMENTITIOUS BACKER BOARD & FULL HEIGHT TILE FINISH ON BOTH SIDES. PROVIDE BATT INSULATION IN CAVITY20 GA 8" MTL STUD @ 16 OC WITH 5/8" CEMENTITIOUS BACKER BOARD & FULL HEIGHT TILE FINISH ON BOTH SIDES. PROVIDE BATT INSULATION IN CAVITYWALL TYPES20 GA 3 5/8" MTL STUD @ 16 OC WITH 5/8" GYPSUM WALL BOARD ON BOTH SIDES. PROVIDE BATT INSULATION IN CAVITYFULLY GROUTED NOM 8" CMU WALL. FOR ADDITIONAL INFORMATION REFER TO STRUCTURAL.FULLY GROUTED NOM 8" CMU WALL WITH MIN R-11.4 CONTINUOUS RIGID INSULATION & 20 GA 2 1/2" MTL STUD FURRING @ 16 OC & 5/8" GYPSUM WALL BOARD FINISH. FOR ADDITIONAL INFORMATION REFER TO STRUCTURAL.20 GA 8" MTL STUD @ 16 OC WITH MIN R-13 BATT INSULATION IN CAVITY AND 5/8" GYPSUM WALL BOARD FINISH ON INTERIOR INSIDE. PROVIDE 5/8" GYPSUM BASE SHEATHING, AIR/ WATER BARRIER MEMBRANE, MIN R-7.5 CONTINUOUS RIGID INSULATION, 7/8" MTL FURRING CHANNELS AT 24" OC HORIZONTALLY AND 1 1/2" MTL PANELS ON THE EXTERIOR SIDE. FULLY GROUTED NOM 8" CMU WALL WITH MIN R-11.4 CONTINUOUS RIGID INSULATION & 20 GA 2 1/2" MTL STUD FURRING @ 16 OC & 5/8" CEMENTITOUS BACKER BOARD w/ FULL HEIGHT TILE FINISH. FOR ADDITIONAL INFORMATION REFER TO STRUCTURAL.R-11.4 CONTINUOUS RIGID INSULATION & 20 GA 2 1/2" MTL STUD FURRING @ 16 OC & 5/8" GYPSUM WALL BOARD FINISHNNOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONAS NOTEDPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:22:52 PM405830BRT-405-APP500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-APP50602/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGARAGE ENLARGED FLOOR PLANSOUTH RENTON TRANSIT CENTER0448SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0"405-APP506GARAGE ENLARGED FLOOR PLAN LEVEL 11 8910COMMUNICATIONSROOMBTP120109STORAGEBTP120108JANITORROOMBTP120107CB60' - 6"15' - 4"17' - 4"6' - 6 3/8"21335489625' - 6"12' - 0"725' - 6"10111219' - 10"40' - 8"2KEY NOTES (THIS SHEET):1. CONCRETE WALL, SEE STRUCT.2. CMU WALL.3. CONCRETE COLUMN, TYP SEE STRUCT.4. MOTORCYCLE STALL, TYP.5. ST ONLY PARKING STALL.6. CONCRETE FLOOR, SEE STRUCT.7. PARKING STALL W/ ELEC CHARGING INFRASTRUCTURE.8. TYPICAL DIAGONAL STRIPING (NO PARKING ZONE).9. CABLE BARRIER, TYP.10. FLOOR MOUNTED MOP SINK11. BUILT-IN SHELFING12. EMERGENCY EYEWASH.20 GA 3 5/8" MTL STUD @ 16 OC WITH 5/8" CEMENTITIOUS BACKER BOARD & FULL HEIGHT TILE FINISH ON ONE SIDE. PROVIDE BATT INSULATION IN CAVITY.20 GA 3 5/8" MTL STUD @ 16 OC WITH 5/8" CEMENTITIOUS BACKER BOARD & FULL HEIGHT TILE FINISH ON BOTH SIDES. PROVIDE BATT INSULATION IN CAVITY20 GA 8" MTL STUD @ 16 OC WITH 5/8" CEMENTITIOUS BACKER BOARD & FULL HEIGHT TILE FINISH ON BOTH SIDES. PROVIDE BATT INSULATION IN CAVITYWALL TYPES20 GA 3 5/8" MTL STUD @ 16 OC WITH 5/8" GYPSUM WALL BOARD ON BOTH SIDES. PROVIDE BATT INSULATION IN CAVITYFULLY GROUTED NOM 8" CMU WALL. FOR ADDITIONAL INFORMATION REFER TO STRUCTURAL.FULLY GROUTED NOM 8" CMU WALL WITH MIN R-11.4 CONTINUOUS RIGID INSULATION & 20 GA 2 1/2" MTL STUD FURRING @ 16 OC & 5/8" GYPSUM WALL BOARD FINISH. FOR ADDITIONAL INFORMATION REFER TO STRUCTURAL.20 GA 8" MTL STUD @ 16 OC WITH MIN R-13 BATT INSULATION IN CAVITY AND 5/8" GYPSUM WALL BOARD FINISH ON INTERIOR INSIDE. PROVIDE 5/8" GYPSUM BASE SHEATHING, AIR/ WATER BARRIER MEMBRANE, MIN R-7.5 CONTINUOUS RIGID INSULATION, 7/8" MTL FURRING CHANNELS AT 24" OC HORIZONTALLY AND 1 1/2" MTL PANELS ON THE EXTERIOR SIDE. FULLY GROUTED NOM 8" CMU WALL WITH MIN R-11.4 CONTINUOUS RIGID INSULATION & 20 GA 2 1/2" MTL STUD FURRING @ 16 OC & 5/8" CEMENTITOUS BACKER BOARD w/ FULL HEIGHT TILE FINISH. FOR ADDITIONAL INFORMATION REFER TO STRUCTURAL.R-11.4 CONTINUOUS RIGID INSULATION & 20 GA 2 1/2" MTL STUD FURRING @ 16 OC & 5/8" GYPSUM WALL BOARD FINISHNNOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONAS NOTEDPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:22:53 PM405840BRT-405-APP500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-APP50702/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGARAGE ENLARGED FLOOR PLANSOUTH RENTON TRANSIT CENTER0448SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0"405-APP507GARAGE ENLARGED FLOOR PLAN LEVEL 11 111213KING COUNTYPANELS ROOMBTP120111SPRINKLERROOMBTP120110/MATCH LINE2405-APP508B21236ELECTRICALROOMBTP1201121' - 8"5' - 1"2' - 7"7' - 11 3/8"20' - 0"8' - 0"12' - 0"ALIGNALIGN14' - 0"2' - 0"4' - 7"WOMEN'SRESTROOMBTP120104MEN'SRESTROOMBTP120106111213/MATCH LINE1405-APP508ELECTRICALROOMBTP120112GENERATORROOMBTP120113C216' - 10 3/8"1' - 8"20' - 0"32541128' - 0"12' - 0"ALIGN23' - 5 5/8"1' - 9"78KEY NOTES (THIS SHEET):1. CMU WALL, SEE STRUCT.2. CONCRETE COLUMN, TYP SEE STRUCT.3. BOLLARD, TYP.4. REMOVABLE FULL HEIGHT WIRE MESH SCREEN.5. TYPICAL DIAGONAL STRIPING (NO PARKING ZONE).6. CHAINLINK PARTITION.7.CONCRETE VEHICLE BARRIER PER STRUCTURAL; TYP.8. METAL LOUVER; REFER TO MECHANICAL DRAWINGS; TYP20 GA 3 5/8" MTL STUD @ 16 OC WITH 5/8" CEMENTITIOUS BACKER BOARD & FULL HEIGHT TILE FINISH ON ONE SIDE. PROVIDE BATT INSULATION IN CAVITY.20 GA 3 5/8" MTL STUD @ 16 OC WITH 5/8" CEMENTITIOUS BACKER BOARD & FULL HEIGHT TILE FINISH ON BOTH SIDES. PROVIDE BATT INSULATION IN CAVITY20 GA 8" MTL STUD @ 16 OC WITH 5/8" CEMENTITIOUS BACKER BOARD & FULL HEIGHT TILE FINISH ON BOTH SIDES. PROVIDE BATT INSULATION IN CAVITYWALL TYPES20 GA 3 5/8" MTL STUD @ 16 OC WITH 5/8" GYPSUM WALL BOARD ON BOTH SIDES. PROVIDE BATT INSULATION IN CAVITYFULLY GROUTED NOM 8" CMU WALL. FOR ADDITIONAL INFORMATION REFER TO STRUCTURAL.FULLY GROUTED NOM 8" CMU WALL WITH MIN R-11.4 CONTINUOUS RIGID INSULATION & 20 GA 2 1/2" MTL STUD FURRING @ 16 OC & 5/8" GYPSUM WALL BOARD FINISH. FOR ADDITIONAL INFORMATION REFER TO STRUCTURAL.20 GA 8" MTL STUD @ 16 OC WITH MIN R-13 BATT INSULATION IN CAVITY AND 5/8" GYPSUM WALL BOARD FINISH ON INTERIOR INSIDE. PROVIDE 5/8" GYPSUM BASE SHEATHING, AIR/ WATER BARRIER MEMBRANE, MIN R-7.5 CONTINUOUS RIGID INSULATION, 7/8" MTL FURRING CHANNELS AT 24" OC HORIZONTALLY AND 1 1/2" MTL PANELS ON THE EXTERIOR SIDE. FULLY GROUTED NOM 8" CMU WALL WITH MIN R-11.4 CONTINUOUS RIGID INSULATION & 20 GA 2 1/2" MTL STUD FURRING @ 16 OC & 5/8" CEMENTITOUS BACKER BOARD w/ FULL HEIGHT TILE FINISH. FOR ADDITIONAL INFORMATION REFER TO STRUCTURAL.R-11.4 CONTINUOUS RIGID INSULATION & 20 GA 2 1/2" MTL STUD FURRING @ 16 OC & 5/8" GYPSUM WALL BOARD FINISHNNOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONAS NOTEDPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:22:54 PM405850BRT-405-APP500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-APP50802/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGARAGE ENLARGED FLOOR PLANSOUTH RENTON TRANSIT CENTERSCALE: 1/4" = 1'-0"405-APP508GARAGE ENLARGED FLOOR PLAN LEVEL 11SCALE: 1/4" = 1'-0"405-APP508GARAGE ENLARGED FLOOR PLAN LEVEL 120448SCALE: 1/4" = 1'-0" A405-AEE501B405-AEE502A405-AEE502B405-AEE501A405-AEX501B405-AEX501AD11.623456789101112138' - 6"1/2" / 1'-0"1/2" / 1'-0"114133567CB1/2" / 1'-0"554460' - 9"60' - 6"60' - 9"182' - 0"269' - 6"12' - 0"8' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"8' - 0"12' - 0"222KEY NOTES:1. SINGLE PLY ROOFING W/ MIN SOLAR REFLECTIVE INDEX (SRI) OF 82.2. OPTIONAL FUTURE PV PANEL3. GLASS CANOPY BELOW4. SCUPPER, CONDUCTOR HEAD AND DOWNSPOUT, TYP.5. PARAPET, TYP6. CONCRETE COLUMN TYP, SEE STRUCT7. RAILING, TYPALLOCATE 30% OF UNOCCUPIED ROOF SPACE FOR FUTURE PV IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODEGENERAL PV NOTE:NNOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONAS NOTEDPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:22:56 PM405860BRT-405-ARP500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-ARP50102/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGARAGE ROOF PLANSOUTH RENTON TRANSIT CENTERSCALE: 1/16" = 1'-0"0161632SCALE: 1/16" = 1'-0"405-ARP501GARAGE ROOF PLAN1 LEVEL 10' -0"LEVEL 211' -6"LEVEL 322' -0"LEVEL 432' -6"LEVEL 543' -0"T.O. PARAPET51' -9"STR RF FRAMING54' -6"B405-AEX50111.62345678910111213LEVEL 2.516' -9"LEVEL 3.527' -3"LEVEL 4.537' -9"LEVEL 5.548' -3"LEVEL 1.55' -9"METAL PANEL CLADDING; TYPAL CURTAIN WALL SYSTEM; TYPMETAL PANEL REVEAL; TYPHIGH PERFORMANCE COATED METAL FRAME WITH WIRE MESH SCREEN; TYPGLAZED CANOPY; TYPAL STOREFRONT SYSTEM; TYPSTACK BOND CMU WALL; TYPCONCRETE COLUMN PER STRUCTURAL; TYPCONCRETE VEHICLE BARRIER PER STRUCTURAL; TYPENTRANCE CANOPY AND SIGNAGEPAINTED METAL GUARD RAIL; TYPSTAINLESS STEEL SHEET METAL SCUPPER, CONDUCTOR HEAD AND DOWNSPOUT; TYPHIGH PERFORMANCE COATED METAL GARAGE SCREENINGHIGH PERFORMANCE COATED STRUCTURAL SCREEN SUPPORTGLAZED CANOPY BEYOND269' - 6"12' - 0"8' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"8' - 0"12' - 0"OPTIONAL FUTURE PV PANEL BEYOND; TYP64'-1 1/2"MAX BLDG HGTLEVEL 10' -0"LEVEL 211' -6"LEVEL 322' -0"LEVEL 432' -6"LEVEL 543' -0"T.O. PARAPET51' -9"STR RF FRAMING54' -6"A405-AEX501ADLEVEL 2.516' -9"LEVEL 3.527' -3"LEVEL 4.537' -9"LEVEL 5.548' -3"LEVEL 1.55' -9"CBHIGH PERFORMANCE COATED STRUCTURAL SCREEN SUPPORT/ SCREEN182' - 0"60' - 9"60' - 6"60' - 9"METAL PANEL CLADDING; TYPAL CURTAIN WALL SYSTEM; TYPMETAL PANEL REVEAL; TYPHIGH PERFORMANCE COATED METAL FRAME WITH WIRE MESH SCREEN; TYPGLAZED CANOPY; TYPAL STOREFRONT SYSTEM; TYPCONCRETE COLUMN PER STRUCTURAL; TYPCONCRETE VEHICLE BARRIER PER STRUCTURAL; TYPSTAINLESS STEEL SHEET METAL SCUPPER, CONDUCTOR HEAD AND DOWNSPOUT; TYPHIGH PERFORMANCE COATED METAL GARAGE SCREENINGBARRIER BEAM AND SIGNAGEOVERHEAD ROLL UP DOORHM METAL DOOR AND DOOR FRAME; TYPOPTIONAL FUTURE PV PANEL BEYOND; TYPGARAGE SCREEN MATERIAL SHALL HAVE PERFORATION OR OPENING THAT MEETS 2018 IBC 406.5.2OPENINGS REQUIREMENTS FOR NATURAL VENTILATION PURPOSES.FACADE DESIGN SHALL COMPLY TO CITY OF RENTON'S URBAN DESIGN REGULATIONS SECTION 4-3-100FACADE SCREEN AND FACADE DESIGN NOTE:ALLOCATE 30% OF UNOCCUPIED ROOF SPACE FOR FUTURE PV IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODEGENERAL PV NOTE:NOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APPREVISIONAS NOTEDPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:21:44 PM405870BRT-405-AEE500AE 0054-17XX/XX/XXXX02/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-AEE50102/11/2022R. GORMANF. ReviewedPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGARAGE EXTERIOR ELEVATIONS - NORTH AND EASTSOUTH RENTON TRANSIT CENTERSCALE: 1/16" = 1'-0"405-AEE501NORTH ELEVATIONASCALE: 1/16" = 1'-0"405-AEE501EAST ELEVATIONBSCALE: 1/16" = 1'-0"0161632 LEVEL 10' -0"LEVEL 211' -6"LEVEL 322' -0"LEVEL 432' -6"LEVEL 543' -0"T.O. PARAPET51' -9"STR RF FRAMING54' -6"B405-AEX50111.62345678910111213LEVEL 2.516' -9"LEVEL 3.527' -3"LEVEL 4.537' -9"LEVEL 5.548' -3"LEVEL 1.55' -9"269' - 6"12' - 0"8' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"8' - 0"12' - 0"STAINLESS STEEL SHEET METAL SCUPPER, CONDUCTOR HEAD AND DOWNSPOUT; TYPMETAL PANEL CLADDING; TYPAL CURTAIN WALL SYSTEM; TYPMETAL PANEL REVEAL; TYPPAINTED METAL GUARD RAIL; TYPENTRANCE SIGNAGEHIGH PERFORMANCE COATED METAL GARAGE SCREENINGHIGH PERFORMANCE COATED STRUCTURAL SCREEN SUPPORTOPTIONAL FUTURE PV PANEL BEYOND; TYPHIGH PERFORMANCE COATED METAL FRAME WITH WIRE MESH SCREEN; TYPGLAZED CANOPY; TYPENTRANCE SIGNAGEGLAZED CANOPY BEYONDCONCRETE COLUMN PER STRUCTURAL; TYPOPTIONAL FUTURE PV PANEL BEYOND; TYPLEVEL 10' -0"LEVEL 211' -6"LEVEL 322' -0"LEVEL 432' -6"LEVEL 543' -0"T.O. PARAPET51' -9"STR RF FRAMING54' -6"A405-AEX501AD182' - 0"LEVEL 2.516' -9"LEVEL 3.527' -3"LEVEL 4.537' -9"LEVEL 5.548' -3"LEVEL 1.55' -9"CB60' - 9"60' - 6"60' - 9"STAINLESS STEEL SHEET METAL SCUPPER, CONDUCTOR HEAD AND DOWNSPOUT; TYPMETAL PANEL CLADDING; TYPAL CURTAIN WALL SYSTEM; TYPMETAL PANEL REVEAL; TYPBARRIER BEAM AND SIGNAGEOVERHEAD ROLL UP DOORGLAZED CANOPY; TYPHIGH PERFORMANCE COATED METAL FRAME WITH WIRE MESH SCREEN; TYPOPTIONAL FUTURE PV PANEL BEYOND; TYPHIGH PERFORMANCE COATED METAL GARAGE SCREENINGHIGH PERFORMANCE COATED STRUCTURAL SCREEN SUPPORT/ SCREENGARAGE SCREEN MATERIAL SHALL HAVE PERFORATION OR OPENING THAT MEETS 2018 IBC 406.5.2OPENINGS REQUIREMENTS FOR NATURAL VENTILATION PURPOSES.FACADE DESIGN SHALL COMPLY TO CITY OF RENTON'S URBAN DESIGN REGULATIONS SECTION 4-3-100FACADE SCREEN AND FACADE DESIGN NOTE:ALLOCATE 30% OF UNOCCUPIED ROOF SPACE FOR FUTURE PV IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODEGENERAL PV NOTE:NOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONAS NOTEDPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:22:22 PM405880BRT-405-AEE500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-AEE50202/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGARAGE EXTERIOR ELEVATIONS - SOUTH AND WESTSOUTH RENTON TRANSIT CENTERSCALE: 1/16" = 1'-0"405-AEE502SOUTH ELEVATIONASCALE: 1/16" = 1'-0"405-AEE502WEST ELEVATIONBSCALE: 1/16" = 1'-0"0161632 DRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:22:22 PMNTS405890BRT-405-AEE500AE 0054-1702/11/2022DesignerAuthorCheckerApproverI-405 BRTCONTRACT UNIT DESCRIPTION 5405-AEE50302/11/2022R. GORMANARCHITECTURALGARAGE EXTERIOR 3D - NW/ SE VIEWSSOUTH RENTON TRANSIT CENTERSCALE: NTS405-AEE503SOUTHEAST VIEWBSCALE: NTS405-AEE503NORTHWEST VIEWA DRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:22:22 PMNTS405900AE 0054-1702/11/2022DesignerAuthorCheckerApproverI-405 BRTCONTRACT UNIT DESCRIPTION 5405-AEE50402/11/2022R. GORMANARCHITECTURALGARAGE EXTERIOR 3D - NE/ SW VIEWSSOUTH RENTON TRANSIT CENTERSCALE: NTS405-AEE504SOUTHWEST VIEWBSCALE: NTS405-AEE504NORTHEAST VIEWA LEVEL 10' -0"LEVEL 211' -6"LEVEL 322' -0"LEVEL 432' -6"LEVEL 543' -0"T.O. PARAPET51' -9"11.62345678910111213269' - 6"12' - 0"8' - 0"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"25' - 6"8' - 0"12' - 0"LEVEL 2.516' -9"LEVEL 3.527' -3"LEVEL 4.537' -9"LEVEL 5.548' -3"LEVEL 1.55' -9"CABLE RAILING; TYPGLAZED CANOPYHIGH PERFORMANCE COATED STRUCTURAL SCREEN SUPPORT; TYPCONCRETE DECK PER STRUCTURAL; TYPCONCRETE RAMP PER STRUCTURAL; TYPOPTIONAL FUTURE PV PANELS BEYOND, TYP8' - 5"7' - 5"LEVEL 10' -0"LEVEL 211' -6"LEVEL 322' -0"LEVEL 432' -6"LEVEL 543' -0"T.O. PARAPET51' -9"AD182' - 0"LEVEL 2.516' -9"LEVEL 3.527' -3"LEVEL 4.537' -9"LEVEL 5.548' -3"LEVEL 1.55' -9"CB60' - 9"60' - 6"60' - 9"124 SFELECTRICAL CLOSET124 SFELECTRICAL CLOSET370 SFGENERATOR ROOM437 SFELECTRICAL ROOM131 SFSECURITY ROOM169 SFWOMEN'S RESTROOM223 SFSPRINKLER ROOMHIGH PERFORMANCE COATED STRUCTURAL SCREEN SUPPORT; TYPOVERHEAD ROLL UP DOORHIGH PERFORMANCE COATED METAL FRAME WITH WIRE MESH SCREEN; TYPSTAINLESS STEEL SHEET METAL SCUPPER, CONDUCTOR HEAD AND DOWNSPOUT; TYPOPTIONAL FUTURE PV PANELS, TYPSTAIR #1CONCRETE DECK PER STRUCTURAL; TYPNOT FOR CONSTRUCTIONDRAWING NO.:FACILITY ID:SHEET No: REV:SCALE:FILENAME:CONTRACT No.:SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY:DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:No.DATEDSN CHK APP REVISIONAS NOTEDPRELIMINARYBIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-A-v2020.rvt1/26/2022 4:22:33 PM405910BRT-405-AEX500AE 0054-1702/11/2022I-405 BRTCONTRACT UNIT DESCRIPTION 5405-AEX50102/11/2022R. GORMANPHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTALARCHITECTURALGARAGE LONGITUDINAL AND TRANSVERSE SECTIONSSOUTH RENTON TRANSIT CENTERSCALE: 1/16" = 1'-0"405-AEX501LONGITUDINAL SECTIONASCALE: 1/16" = 1'-0"405-AEX501TRANSVERSE SECTIONBSCALE: 1/16" = 1'-0"0161632 ABBREVIATIONS - MECHANICAL ABV ABOVE AC AIR CONDITIONING UNIT ACC AIR COOLED CONDENSER ACD AUTOMATIC CONTROL DAMPER AD ACCESS DOOR AL ACOUSTICAL LINING ARCH ARCHITECTURAL ATC AUTOMATIC TEMPERATURE CONTROL BD BALANCING DAMPER BDD BACK DRAFT DAMPER BMS BUILDING MANAGEMENT SYSTEM BHP BRAKE HORSE POWER BTU BRITISH THERMAL UNIT CC COOLING COIL CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE CG CEILING GRILLE CR CEILING REGISTER DB DRY BULB DIA DIAMETER DN DOWN DX DIRECT EXPANSION (E)EXISTING TO REMAIN EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE EDB ENTERING DRY BULB EF EXHAUST FAN EFF EFFICIENCY ELEV ELEVATOR EHC ELECTRIC HEATING COIL EUH ELECTRIC UNIT HEATER EWB ENTERING WET BULB °F DEGREES FAHRENHEIT F FILTER FBO FURNISHED BY OTHERS FC FLEXIBLE CONNECTION (DUCT OR PIPE) FD FUSIBLE LINK FIRE DAMPER W/ DUCT ACCESS DOOR FLR FLOOR FLA FULL LOAD AMPS FPI FINS PER INCH FRE FIRE RATED ENCLOSURE FSD COMBINATION FIRE AND SMOKE DAMPER FT FEET HC HEATING COIL HTP HEAT PUMP HP HORSE POWER HR HOUR HRU HEAT RECOVERY UNIT ID INSIDE DIMENSION KW KILOWATT KWH KILOWATT HOURS LAT LEAVING AIR TEMPERATURE LBS POUNDS LWS LOUVER WITH WIRE SCREEN MAT MIXED AIR TEMPERATURE MAX MAXIMUM MBH THOUSAND BTU PER HOUR MFG MANUFACTURER ABBREVIATIONS - MECHANICAL MFS MAXIMUM FUSE SIZE MIN MINIMUM MOCP MAXIMUM OVERCURRENT PROTECTION NC NORMALLY CLOSED NFA NET FREE AREA NIC NOT IN THIS CONTRACT NK NECK NO NORMALLY OPEN NTS NOT TO SCALE OAI OUTSIDE AIR INTAKE OBD OPPOSED BLADE DAMPER OD OUTSIDE DIMENSION PD PRESSURE DROP PSI POUNDS PER SQUARE INCH (GAUGE) PSIA POUNDS PER SQUARE INCH ABSOLUTE RA RETURN AIR RF RETURN FAN RH RELATIVE HUMIDITY RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR SAD SEE ARCHITECTURAL DRAWINGS SF SUPPLY FAN SED SEE ELECTRICAL DRAWINGS SENS SENSIBLE SM SHEET METAL SP STATIC PRESSURE SQFT SQUARE FEET ST SOUND TRAP TX TOILET EXHAUST TYP TYPICAL UH UNIT HEATER UON UNLESS OTHERWISE NOTED VAR VARIABLE VD VOLUME DAMPER VFD VARIABLE FREQUENCY DRIVE W/WITH WB WET BULB WG WATER GAUGE WMS WIRE MESH SCREEN WO-SIZE WALL OPENING - [SIZE] (300) CUBIC FEET OR AIR PER MINUTE OR GALLONS PER MINUTE CEILING DIFFUSER 1-WAY BLOW 3-WAY BLOW 4-WAY BLOW2-WAY BLOW MECHANICAL LEGEND AND ABBREVIATIONS 18x12 18x12 DUCTWORK LEGEND U MISCELLANEOUS 18 18 2 M3.1 CT 1-1 SR-A,12x8 1 M2.1 WO-SIZE (200) SR-A,12x8 (200) (200) ER-C,12x8 (200) ER-C,12x8 CD-1,12x12 (550) CD-1,12x12 (550) DUCTWORK LEGEND (CONTINUED) RETURN/EXHAUST REGISTER OR GRILLE WITH FLEXIBLE DUCT CONNECTION CEILING DIFFUSER WITH FLEXIBLE DUCT CONNECTION RETURN/EXHAUST REGISTER OR GRILLE UNDERCUT DOOR TRANSFER GRILLES ON BOTH SIDES OF PARTITION OR WALL (SIZE) WALL OPENING ABOVE HUNG CEILING (SIZE) SUPPLY REGISTER WITH AIR OUTLET DEVICE DESIGNATION RETURN OR EXHAUST REGISTER OR GRILLE WITH AIR INLET DEVICE DESIGNATION BACK DRAFT DAMPER WITH DUCT ACCESS DOOR DUCT SPLIT WITH SPLIT SIZE RADIUS ELBOW RECTANGULAR SUPPLY DUCT UP RECTANGULAR SUPPLY DUCT DOWN RECTANGULAR RETURN OR EXHAUST DUCT UP RECTANGULAR RETURN OR EXHAUST DUCT DOWN ROUND DUCT, UP ROUND DUCT, DOWN BEAM PENETRATION DUCT SIZE (CLEAR INSIDE DIMENSION) FIRST FIGURE INDICATES PLAN SIZE ROUND DUCT DIAMETER SIZE (CLEAR INSIDE DIMENSION) DIAMETER RISER DESIGNATION SECTION DESIGNATION DETAIL DESIGNATION EQUIPMENT DESIGNATION AIR OUTLET/INLET DEVICE DESIGNATION RISER SERVICE RISER NUMBER SECTION NUMBER DRAWING NUMBER DETAIL NUMBER DRAWING NUMBER EQUIPMENT TYPE EQUIPMENT FLOOR AND NUMBER TYPE NECK OR FACE SIZE CFM SIDE, TOP OR BOTTOM DUCT ACCESS DOOR ELBOW WITH TURNING VANES RECTANGULAR BRANCH TAKEOFF WITH BALANCING DAMPER HW 1 8x6 8x616x6 16x6 DRAWING REVISION DESIGNATION WITH NUMBERS KEYNOTE 1 AUTOMATIC CONTROL DAMPER VOLUME DAMPER IN DUCT DUCT LINING (DUCT SIZE NOTED INDICATES INSIDE DIMENSIONS) FLEXIBLE CONNECTION FLEXIBLE DUCT RECTANGULAR OR SQUARE TO ROUND OR OVAL TRANSITION DUCT END/CAP T TEMPERATURE SENSOR/THERMOSTAT PIPING LEGEND REFRIGERANT LIQUID PIPING RL RL REFRIGERANT SUCTION PIPINGRS RS ELBOW TURNED UP ELBOW TURNED DOWN TOP PIPE CONNECTION UNION SHUT-OFF VALVE BOTTOM PIPE CONNECTION CAPPED PIPE WITH SHUT-OFF VALVE D CONDENSING UNIT ACU AIR CONDITIONING UNIT ARROW INDICATES DIRECTION OF FLOW CONDENSATE DRAIN PIPINGD D DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTSPRELIMINARY SOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-M-v2020.rvt2/2/2022 7:24:54 PM405 92 0 AE 0054-17 JC JC TS I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MHN501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL HVAC LEGENDS AND ABBREVIATIONS BRT-405-MHP500N GENERAL NOTES: 1. THE FOLLOWING NOTES APPLY TO ALL MECHANICAL DRAWINGS. ADDITIONAL NOTES MAY BE INDICATED ON INDIVIDUAL DRAWINGS. 2. DRAWINGS INDICATE THE WORK OF THE TRADES. VERIFY LOCATION OF EQUIPMENT, ROUGH-IN LOCATIONS, AND TYPE OF CONNECTIONS PRIOR TO PREPARATION OF SHOP DRAWINGS SUBMITTALS , AND PRIOR TO INSTALLATION OF SERVICE CONNECTIONS. DO NOT INTERFERE WITH ACCESS FOR MAINTENANCE AND REMOVAL OR REPLACEMENT OF EQUIPMENT. 3. COORDINATE THE PHASING AND INSTALLATION OF NEW WORK WITH THE WORK OF ALL OTHER TRADES. BEAR THE EXPENSE FOR ANY ADDITIONAL WORK WHICH MAY BE CAUSED BY IMPROPER SEQUENCING OF CONSTRUCTION ACTIVITIES. 4. REFER TO ARCHITECTURAL DRAWINGS FOR ELEVATIONS OF DEVICES IN FINISHED AREAS AND AT HEIGHTS INDICATED ON ARCHITECTURAL ELEVATIONS. LOCATE MECHANICAL DEVICES (E.G. TEMPERATURE SENSORS, PANELS AND SWITCHES), SO THAT THEY DO NOT CONFLICT WITH GENERAL CONSTRUCTION (E.G. WAINSCOT, DOOR HARDWARE), ELECTRICAL DEVICES (E.G. LIGHT SWITCHES, SPEAKERS, OUTLETS), AND THE WORK OF OTHER TRADES. 5. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL CONSTRUCTION INCLUDING, BUT NOT LIMITED TO, EQUIPMENT HOUSEKEEPING PADS, PENETRATION DETAILS, FLASHING AND SEALING DETAILS, AND OTHER ELEMENTS OF GENERAL CONSTRUCTION. COORDINATE THE SIZE AND LOCATION OF EQUIPMENT HOUSEKEEPING PADS WITH APPROVED EQUIPMENT SO THAT HOUSEKEEPING PADS ARE NOMINALLY 4" HIGH UNLESS INDICATED OTHERWISE, AND EXTEND 6" MINIMUM IN ALL DIRECTIONS FRO THE HORIZONTAL LIMITS OF THE EQUIPMENT WHICH THY SUPPORT. 6. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF CEILING MOUNTED ITEMS, INSTALL CEILING MOUNTED ITEMS IN THE CENTER OF CEILING TILES, IN THE CENTER OF ROOMS, OR WHERE INDICATED ON ARCHITECTURAL DRAWINGS. WHERE LOCATION OF ITEMS ARE NOT INDICATED ON ARCHITECTURAL DRAWINGS, OBTAIN DIRECTIONS FROM ARCHITECT PRIOR TO ROUGH-IN AND INSTALLATION. 7. COORDINATE EQUIPMENT POWER CONNECTION AND ELECTRICAL CHARACTERISTICS WITH ELECTRICAL DRAWINGS AND CONNECTION REQUIREMENTS. COORDINATE VARIATION IN ELECTRICAL CHARACTERISTICS FROM SCHEDULE VALUES. CHANGES TO ELECTRICAL CHARACTERISTICS (E.G. VOLTAGE, AMPS, HORSEPOWER ETC.)SHALL BE SUBJECT TO APPROVAL. BEAR THE TOTAL EXPENSE FOR REQUIRED REVISIONS TO THE ELECTRICAL SCOPE OF WORK CAUSED BY VARIATION FROM THE SCHEDULED REQUIREMENTS. 8. EQUIPMENT SHORT CIRCUIT RATINGS (SCCR) SHALL BE NOT LESS THAN THE INTERRUPTING RATING OF THE BRANCH CIRCUIT OVERCURRENT PROTECTIVE DEVICE SUPPLYING POWER TO THE EQUIPMENT. REFER TO SCHEDULES FOR BRANCH CIRCUIT OVERCURRENT DEVICE INTERRUPTING RATINGS. 9. COORDINATE THE LOCATION OF WORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES AND OTHER CEILING MOUNTED DEVICES AS REQUIRED TO ALLOW FOR REMOVAL AND MAINTENANCE ACCESS. 10. DO NOT RESTRICT ACCESS TO ELECTRICAL CABLE TRAYS. AT A MINIMUM, ALLOW 18" CLEAR ON ONE SIDE OF CABLE TRAYS UP TO AN ELEVATION OF 6" ABOVE THE TOP OF THE CABLE TRAY. MAINTAIN 12" MINIMUM CLEARANCE OVER TOP OF CABLE TRAYS EXCEPT WHERE DUCT, PIPING, OR CONDUIT CROSS PERPENDICULAR TO CABLE TRAY, THIS CLEARANCE MAY BE REDUCED TO 6" OVER A DISTANCE OF NO MORE THAN 36" ALONG THE CABLE TRAY. PROVIDE NO LESS THAN 36" BETWEEN AREAS OF REDUCED CLEARANCE AND MAINTAIN INDICATED ACCESS ON THE SAME SIDE OF THE CABLE TRAY EXCEPT WHERE OTHERWISE APPROVED. DO NOT CONNECT OTHER TRADE ITEMS TO CABLE TRAY, CABLE TRAY SUPPORTS OR CABLE TRAY SEISMIC RESTRAINTS. 11. PROVIDE SUPPORT AND SEISMIC RESTRAINTS FOR PIPES, AND EQUIPMENT AS SPECIFIED, AS REQUIRED, AND AS SHOWN ON THE DRAWINGS.IF REQUIRED FOR INSTALLATION OF PIPES, DUCTS, AND EQUIPMENT, DESIGN AND PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMN, JOISTS, AND STRUCTURAL FRAME TO MEET SUPPORT AND SEISMIC RESTRAINT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS AND ANCHORAGES SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED. REFER TO STRUCTURAL DRAWINGS FOR DESIGN CRITERIA. SUBMIT STRUCTURAL MEMBER SHOP DRAWINGS AND CALCULATIONS FOR REVIEW. STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS SHOWN ON THE STRUCTURAL DRAWINGS AND INDICATED IN THE SPECIFICATIONS. NO WELDING, BOLTING, OR OTHER MEANS OF ATTACHMENTS TO THE STRUCTURAL MEMBERS SHALL BE MADE ON PORTIONS OF STRUCTURAL MEMBERS AT OR NEAR CONNECTIONS BETWEEN STRUCTURAL MEMBERS ON ANY ELEMENTS DESIGNATED IN THE SEISMIC LOAD RESISTING SYSTEMS UNLESS APPROVED BY THE STRUCTURAL ENGINEER. SUPPORTS SHALL NOT INDUCE TORSIONAL LOAD INTO SUPPORTING STRUCTURAL FRAMING. 12. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS OR SHEAR WALLS UNLESS INDICATED ON STRUCTURAL DRAWINGS OR AS APPROVED BY THE STRUCTURAL ENGINEER. 13. PROVIDE PIPE SLEEVES AND PENETRATION SEALS AS REQUIRED FOR THE INSTALLATION OF PIPING SYSTEMS. REFER TO SPECIFICATIONS FOR REQUIREMENTS. 14. COORDINATE THE LAYOUT OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCE SO THAT IT FITS INTO THE SPACE ALLOTTED. PROVIDE SERVICE ACCESS AND CLEARANCE AS INDICATED ON DRAWINGS, AS REQUIRED BY CODES, AND AS RECOMMENDED BY THE MANUFACTURER FOR THE INSTALLATION, REMOVAL, ENTRY, SERVICING, AND MAINTENANCE OF EQUIPMENT. PRIOR TO INSTALLATION, COORDINATE LAYOUT OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES WITH ALL OTHER TRADES TO AVOID BLOCKING SERVICE OR REPLACEMENT ACCESS FOR NEW AND EXISTING EQUIPMENT AND EQUIPMENT INSTALLED BY OTHERS. 15. DRAWINGS ARE DIAGRAMMATIC AND SHOW APPROXIMATE LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES. DRAWINGS DO NOT SHOW REQUIRED TRANSITIONS, OFFSETS, FITTING, AND DEVICES. REFER TO DETAILS, DIAGRAMS, AND SPECIFICATIONS FOR REQUIRED SYSTEM APPURTENANCES, CONTROL DEVICES, ETC. INSTALL DEVICES IN ACCORDANCE WITH DEVICE MANUFACTURER RECOMMENDATIONS. CAREFULLY INVESTIGATE ELEMENTS OF CONSTRUCTION THAT COULD AFFECT THE WORK TO BE PERFORMED AND ARRANGE NEW WORK ACCORDINGLY. PREPARE COORDINATION DRAWINGS FOR NEW WORK, WHICH ARE COORDINATED WITH THE APPROVED AND INSTALLED WORK OF OTHER TRADES. PROVIDE REQUIRED OFFSETS, FITTING, TRANSITIONS, SUPPORTS AND OTHER APPURTENANCES AS REQUIRED. BEAR THE TOTAL EXPENSE OF RE-WORK THAT IS CAUSED BY FAILURE TO COORDINATE. 16. PROVIDE MAXIMUM HEADROOM AND CLEARANCE BELOW DUCTWORK, PIPING AND EQUIPMENT AND ASSOCIATED SUPPORTS AND RESTRAINTS. UNLESS OTHERWISE INDICATED, INSTALL TIGHT TO STRUCTURAL SYSTEMS ABOVE. WHERE WALL MOUNTED, INSTALL AS CLOSE TO WALL AS POSSIBLE. PROVIDE ADDITIONAL FITTINGS AND OFFSETS AS REQUIRED. 17. REFER TO EQUIPMENT SCHEDULE FOR DESIGN CAPACITIES. SCHEDULED VALUES SHALL BE CONSIDERED DESIGN CAPACITIES. PROVIDE EQUIPMENT WHICH MEET OR EXCEEDS THE SCHEDULED VALUES. MARK THE CONTRACT DRAWING EQUIPMENT SCHEDULES TO INDICATE THE MANUFACTURER, MODEL AND CAPACITY OF THE ACTUAL APPROVED EQUIPMENT PROVIDED AND SUBMIT THIS INFORMATION WITH RECORD DRAWINGS AS PART OF PROJECT CLOSEOUT. 18. TO ENHANCE THE CLARITY OF PLAN DRAWINGS, AND WHERE NOT NECESSARY TO DESCRIBE THE REQUIRED SIZE, INDIVIDUAL SEGMENTS OF DUCT AND PIPE BETWEEN CONNECTIONS MAY BE SHOWN WITHOUT A SIZE INDICATED. WHERE SIZE IS NOT SHOWN ON PLANS, THAT SEGMENT SHALL BE THE SAME SIZE AS THE NEXT UPSTREAM SEGMENT WITH A SIZE INDICATED. 19. WHERE NOT INDICATED ON PLANS, REFER TO EQUIPMENT SCHEDULES AND DETAILS FOR INLET AND OUTLET DUCT AND/ OR PIPE SIZE. WHERE INDICATED ON PLANS, PLAN SIZES SHALL TAKE PRECEDENCE. 20. DUCTWORK SERVING INDIVIDUAL DIFFUSERS AND GRILLES IS GENERALLY NOT SIZED. WHERE NOT INDICATED ON PLAN DRAWINGS, REFER TO SCHEDULES AND DETAILS FOR NECK AND BRANCH DUCT SIZES BASED ON INDICATED AIRFLOW RATE ON NECK SIZE. 21. INSTALL DRAINS AT ALL LOW POINTS IN PIPING, INCLUDING ANY TRAPPED PORTIONS OF PIPING. PROVIDE MANUAL AIR VENTS AT ALL HIGH POINTS IN CLOSED LOOP (MECHANICAL) PIPING SYSTEM. IN GENERAL, THESE DEVICES ARE NOT INDICATED ON DRAWINGS. WHERE AUTOMATIC AIR VENTS ARE INDICATED ON DRAWINGS, EXTEND AUTOMATIC AIR VENT (AAV) DISCHARGE TO NEAREST FLOOR DRAIN USING INDIRECT DRAIN PIPING OF SAME SIZE AS AAV DISCHARGE. INDICATED THE ACTUAL LOCATION ON FIELD-LOCATION DRAINS, VENTS AND DRAIN PIPING ON THE RECORD DRAWINGS. 22. PROVIDE A MANUAL VOLUME DAMPER FOR: (1) EACH SUPPLY, RETURN, AND EXHAUST OPENING (2) IN ALL BRANCH DUCTS WHERE THREE OR MORE OPENING ARE ASSOCIATED WITH BRANCH, AND ELSEWHERE AS NOTED ON DRAWINGS OR IN SPECIFICATIONS. LOCATE VOLUME DAMPERS AS FAR AS POSSIBLE FROM OPENINGS. FOR THE PURPOSE OF THIS REQUIREMENT , TERMINAL UNIT PRIMARY AIR DAMPERS ARE CONSIDERED A VOLUME DAMPERS. VOLUME DAMPERS ARE NOT REQUIRED FOR CEILING RETURN GRILLES THAT TRANSFER AIR TO A RETURN AIR PLENUM UNLESS OTHERWISE NOTED. 23. PROVIDE CONICAL TAPS FOR 90 DEGREE ROUND DUCT BRANCHES FROM RECTANGULAR SUPPLY DUCTWORK. DO NOT USE STRAIGHT TEE FITTINGS UNLESS SPECIFICALLY INDICATED ON DRAWINGS. 24. DUCTWORK STATIC PRESSURE AND SEAL CLASS, BASED ON SMACNA HDCS: DUCT SYSTEM STATIC PRESSURE SEAL CLASS A. UPSTREAM OF FAN COIL UNITS PLUS 4 A B. DONWSTREAM OF FAN COIL UNITS PLUS 2 B C. UPSTREAM OF EXHAUST FANS PLUS 2 B D. DOWNSTREAM OF EXHAUST FANS MINUS 2 B E. OUTSIDE AIR INTAKE DUCTWORK MINUS 4 A F. TRANSFER DUCTWORK MINUS 2 B G. EXHAUST DUCTWORK UPSTREAM OF HEAT RECOVERY UNITS MINUS 4 A H. EXHAUST DUCTWORK DOWNSTREAM OF HEAT RECOVERY UNITS PLUS 4 A 25. PROVIDE DUCT LINING FOR DUCTWORK AND PLENUMS AS SPECIFIED, WHERE INDICATED ON DRAWINGS AND AS INDICATED BELOW. DUCT SIZES INDICATED ON DRAWINGS ARE NET INSIDE DIMENSIONS REPRESENTING THE MINIMUM DUCT FREE AREA. THICKNESS OF DUCT LINING SHALL BE AS SPECIFIED UNLESS A GREATER THICKNESS IS INDICATED ON DRAWINGS. FOR CLARITY, DUCT LINING MAY NOT BE SHOWN IN ALL REQUIRED LOCATIONS ON DRAWINGS. PROVIDE DUCT LINING FOR THE FOLLOWING: A. RECTANGULAR SUPPLY AIR DUCTWORK FROM HEAT RECOVERY UNITS TO TERMINAL UNITS AND AS INDICATED ON DRAWINGS. B. PLENUMS UPSTREAM OF RETURN/EXHAUST FANS. C. TOILET EXHAUST DUCTWORK FROM EACH EXHAUST GRILLE TO A POINT 10' DOWNSTREAM OF GRILLE. D. ROUND SUPPLY AIR DUCTWORK. E. ROUND RETURN AIR DUCTWORK. F. ALL AIR TRANSFER DUCTS. 26. THE FOLLOWING IS A LIST OF DEFERRED SUBMITTALS ITEMS. DO NOT INSTALL DEFERRED SUBMITTALS ITEMS UNIT HE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. A. SEISMIC AND WIND RESTRAINTS. 27. REFER TO THE 2018 WASHINGTON STATE ENERGY CODE COMPLIANCE SCHEDULE FOR ADDITIONAL MECHANICAL REQUIREMENTS. 28. ALL DUCT BRANCHES LEADING TO DIFFUSERS ARE TO MATCH NECK SIZE OF DIFFUSER UNLESS NOTED OTHERWISE. 29. PROVIDE WIRE MESH SCREEN FOR ALL OPEN ENDED DUCT SHOWN ON PLANS. 30. MECHANICAL SYSTEM COMMISSIONING SHALL BE COMPLETED AS PER WSEC SECTION C408. DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTSPRELIMINARY SOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-M-v2020.rvt2/2/2022 7:24:55 PM405 93 0 AE 0054-17 JC JC TS I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MHN502PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL HVAC GENERAL NOTES BRT-405-MHP500 VENTILATION CALCULATIONS Zone Room: Name Room: Number Area Space Type Outdoor Air per Person Outdoor Air per Area Occupancy Unit Number of People Outdoor Airflow ACU-1-3 SECURITY ROOM BTP120102 131 SF Office - Enclosed 5 CFM 0.06 CFM/SF Number of people 2 18 CFM ACU-1-4 LACTATION ROOM BTP120103 76 SF Office - Enclosed 5 CFM 0.06 CFM/SF Number of people 1 10 CFM N BTP120105 BTP120104 ELEV#2 ELEV#1 BTP120106 BTP120101 BTP120109 BTP120107 BTP120102 BTP120103 BTP120108 BTP120110 BTP120111 BTP120112 BTP120113 STR#1 STR#2 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 405-MHP506 2 405-MHP506 1 405-MHP505 1 405-MHP505 2 N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARY SOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-M-v2020.rvt2/2/2022 7:24:57 PM405 94 0 AE 0054-17 JC JC TS I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MHP501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL HVAC PLAN - LEVEL 1 BRT-405-MHP500 SCALE: 1/16" = 1'-0"405-MHP501 MECHANICAL PLAN - LEVEL 1 & 1.5 1 ELEV#2 ELEV#1 BTP120202 BTP120201 BTP120203 UP4.2% UP4.2% STR#2 STR#1 UP TO LEVEL 3 DOWN TO LEVEL 1.5 UP TO LEVEL 2.5 UP TO LEVEL 2.5 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 405-MHP507 1 405-MHP507 3 N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARY SOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-M-v2020.rvt2/2/2022 7:25:02 PM405 95 0 AE 0054-17 JC JC TS I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MHP502PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL HVAC PLAN - LEVEL 2 BRT-405-MHP500 SCALE: 1/16" = 1'-0"405-MHP502 MECHANICAL PLAN - LEVEL 2 & 2.5 1 ELEV#2 ELEV#1 BTP120402 BTP120401 BTP120403 UP4.2% UP4.2% STR#2 STR#1 UP TO LEVEL 5 DOWN TO LEVEL 3.5 UP TO LEVEL 4.5 UP TO LEVEL 4.5 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 405-MHP507 2 405-MHP507 4 N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARY SOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-M-v2020.rvt2/2/2022 7:25:07 PM405 96 0 AE 0054-17 JC JC TS I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MHP504PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL HVAC PLAN - LEVEL 4 BRT-405-MHP500 SCALE: 1/16" = 1'-0"405-MHP504 MECHANICAL PLAN - LEVEL 4 & 4.5 1 C 11 12 13 ELECTRICAL ROOM BTP120112 GENERATOR ROOM BTP120113 EFAN 1-1 T HTR 1-1 KING COUNTY PANELS ROOM BTP120111 24x24 FUEL FILL PORT 300 kVA GENSET WITH BELLY TANK 6ø GENERATOR FLUE ACD PROVIDE LOUVER SIZE AT MINIMUM 5 SF NFA PROVIDE LOUVER SIZE AT MINIMUM 2.5 SF NFA PROVIDE LOUVER SIZE MINIMUM AT 30 SF NFA PROVIDE WIRE MESH OPENING SIZE AT MINIMUM 30 SF NFA EXHAUST SILENCER 6ø3' - 0"ACD 64x24 HTR 1-8 2 2 2 4 24x24 5 6 11 12 13 SECURITY ROOM BTP120102 LACTATION ROOM BTP120103 WOMEN'S RESTROOM BTP120104 MEN'S RESTROOM BTP120106 ALL GENDER RESTROOM BTP120105 SPRINKLER ROOM BTP120110 HTR 1-2 EFAN 1-2 EFAN 1-3 EFAN 1-4 ERV 1-1 HTR 1-4 HTR 1-3 HTR 1-5 CU 1-4 ACU 1-4 ACU 1-3 TT 3/4" D CONNECT TO TAIL PIECE. SEE MHD501 FOR DETAIL 6ø6ø 6ø 6ø 1 1 BDD BDD CU 1-3 PROVIDE LOUVER SIZE AT MINIMUM 0.3 SF NFA SG-A,8x6 (40) RG-A,8x6 (40) RG-A,8x6 (20) SG-A,8x6 (20) PROVIDE LOUVER SIZE AT MINIMUM 1.0 SF NFA 1 6ø 10ø8ø6ø6ø 16x8 BDD BDD BDD 2 2 3 3 N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARY SOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-M-v2020.rvt2/2/2022 7:25:10 PM405 97 0 AE 0054-17 JC JC TS I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MHP505PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL HVAC ENLARGED PLAN - LEVEL 1 BRT-405-MHP500 SCALE: 1/4" = 1'-0"405-MHP505 MECHANICAL - LEVEL 1 ENLARGED PLAN - A 1 SCALE: 1/4" = 1'-0"405-MHP505 MECHANICAL - LEVEL 1 ENLARGED PLAN - B 2 NUMBERED NOTES: 1 EFAN TO BE CONTROLLED BY OCCUPANCY SENSOR, WITH A 15 MINUTE TIME-DELAY TO TURN OFF. 2 LOUVER TO BE PROVIDED BY OTHERS, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT SIZE OF LOUVER. 3 INSTALL CONDENSER UNIT ON A MINIMUM 4-INCH HIGH CONCRETE PAD PROVIDED BY OTHERS. PROTECTION BOLLARD TO BE PROVIDED BY OTHERS. 4 PROVIDE WIRE MESH SCREEN FOR THE OPEN ENDED DUCT. 5 GENERATOR FLUE PIPE TO BE TERMINATED 3' FROM BUILDING. 6 PROTECTION BOLLARD OF FUEL FILL PORT TO BE PROVIDED BY OTHERS. 9 JANITOR ROOM BTP120107 STORAGE BTP120108 COMMUNICATIONS ROOM BTP120109 HTR 1-6 EFAN 1-5 ACU 1-2 CU 1-2 HTR 1-7 T 3/4" D TO DRAIN OUTSIDE BDD PROVIDE LOUVER SIZE AT MINIMUM 0.3 SF NFA 1 2 A 8 9 ELEVATOR MACHINE ROOM BTP120101 CU 1-1 ACU 1-1 T 30x1030x10 30x10 3/4" D TO DRAIN OUTSIDE SG-A,30x10 (800) RG-A,30x10 (800) 1 N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARY SOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-M-v2020.rvt2/2/2022 7:25:12 PM405 98 0 AE 0054-17 JC JC TS I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MHP506PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL HVAC ENLARGED PLAN - LEVEL 1 BRT-405-MHP500 1/4" = 1'-0"2 MECHANICAL - LEVEL 1 ENLARGED PLAN - D 1/4" = 1'-0"1 MECHANICAL - LEVEL 1 ENLARGED PLAN - C NUMBERED NOTES: 1 INSTALL CONDENSER UNIT ON A MINIMUM 4-INCH HIGH CONCRETE PAD PROVIDED BY OTHERS. PROTECTION BOLLARD TO BE PROVIDED BY OTHERS. 2 LOUVER TO BE PROVIDED BY OTHERS, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT SIZE OF LOUVER. D 1 1.6 CU 4-2 ACU 4-2 T COMMUNICATIONS CLOSET BTP120203 3/4" D TO DRAIN OUTSIDE 2 D 11 12 13 D 11 12 13 COMMUNICATIONS CLOSET BTP120401ELECTRICAL CLOSET BTP120402 EFAN 4-1 ACU 4-1 CU 4-1 TT HTR 4-1 24x12 3/4" D TO DRAIN OUTSIDE ACD PROVIDE LOUVER SIZE AT MINIMUM 1.0 SF NFA PROVIDE LOUVER SIZE AT MINIMUM 1.0 SF NFA ACD 24x12 1 1 2 24x24 D 11 12 13 COMMUNICATIONS CLOSET BTP120201 ELECTRICAL CLOSET BTP120202 ACU 2-1 CU 2-1 EFAN 2-1 TT HTR 2-1 24x12 3/4" D TO DRAIN OUTSIDE ACD ACD PROVIDE LOUVER SIZE AT MINIMUM 1.0 SF NFA PROVIDE LOUVER SIZE AT MINIMUM 1.0 SF NFA 24x12 1 1 2 3 24x24 D 1 1.6 ACU 2-2 T COMMUNICATIONS CLOSET BTP120203 3/4" D TO DRAIN OUTSIDE CU 2-2 2 N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARY SOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-M-v2020.rvt2/2/2022 7:25:14 PM405 99 0 AE 0054-17 JC JC TS I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MHP507PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL HVAC ENLARGED PLAN - LEVEL 2 AND 4 BRT-405-MHP500 1/4" = 1'-0"2 MECHANICAL - LEVEL 4 ENLARGED PLAN - A 1/4" = 1'-0"4 MECHANICAL - LEVEL 4 ENLARGED PLAN - B 1/4" = 1'-0"1 MECHANICAL - LEVEL 2 ENLARGED PLAN - A 1/4" = 1'-0"3 MECHANICAL - LEVEL 2 ENLARGED PLAN - B NUMBERED NOTES: 1 LOUVER TO BE PROVIDED BY OTHERS, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT SIZE OF LOUVER. 2 INSTALL CONDENSER UNIT ON A MINIMUM 4-INCH HIGH CONCRETE PAD PROVIDED BY OTHERS. PROTECTION BOLLARD TO BE PROVIDED BY OTHERS. 3 PROVIDE WIRE MESH SCREEN FOR THE OPEN ENDED DUCT. T SPACE TEMPERATURE SENSOR AI EXHAUST FAN STATUS: DI ENABLE: DO MOTORIZED DAMPER OPEN/CLOSE: DO END SWITCH: DI MOTORIZED DAMPER OPEN/CLOSE: DO END SWITCH: DI M M EFAN-1-1 EFAN-2-1 EFAN-4-1 DISCONNECT SWITCH SEQUENCE OF OPERATION: 1. THE BMS SHALL OPEN THE DAMPERS AND CYCLE THE FAN ON UPON A TEMPERATURE ABOVE SETPOINT. 2. THE FAN SHALL RUN UNTIL THE TEMPERATURE IN THE SPACE IS BELOW SETPOINT AND THE DAMPERS SHALL CLOSE WHEN THE FAN IS OFF. 3. SETPOINT -85°F 4. ALARM A. TEMPERATURE READING 20° ABOVE OR BELOW SETPOINT. HTR-1-1 THRU HTR-4-1 ELECTRIC HEATER T SPACE TEMPERATURE SENSOR: AI ELEC. HEATER STATUS: DI ELEC. HEATER ENABLE: DO NOT APPLIABLE TO HEATER WITH INTEGRAL THERMOSTAT SEQUENCE OF OPERATION: 1. THE UNIT SHALL CYCLE THE FAN AND ELECTRIC COIL ON TO MAINTAIN SETPOINT. 2. WHEN SETPOINT IS REACHED THE UNIT SHALL TURN OFF. 3. SETPOINT -70°F 4. ALARM A. TEMPERATURE READING 20° ABOVE OR BELOW SETPOINT. CALL: DO STATUS: AI FAULT: DI DP OBC ACU-1-1 THRU CU-4-2 CU OUTDOOR CONDENSING UNIT. TYP. RSRL ON/OFF: DI ENABLE/DISABLE: DO FILTER: DI UNIT TROUBLE: DI UNIT RUNNING: DI T SEQUENCE OF OPERATION: 1. THE BMS SHALL ENABLE THE MANUFACTURES CONTROL SYSTEM FOR THE EQUIPMENT. 2. THE EQUIPMENT SHALL RUN AND BE CONTROLLED BASED ON THE PREPROGRAMMED EQUIPMENT SEQUENCES OF OPERATION 3. THE EQUIPMENT SHALL CONTROL TO MAINTAIN TEMPERATURE SETPOINT IN THE SPACES 4. SETPOINTS A. MACHINE ROOM SPACES ARE OCCUPIED 24/7. REGULARLY OCCUPIED SPACES SHALL WORK OFF A SCHEDULE. B. OCCUPIED a. HEATING -70°F b. COOLING -75°F C. UNOCCUPIED a. HEATING -55°F b. COOLING -85°F 5. ALARM A. ALL ALARMS FROM THE MANUFACTURES CONTROL SYSTEM DPT EA SA RA OSA OUTDOOR AIR FILTER EXHAUST AIR FILTER DPT STATUS: DI ERV-1-1 ERV-1-1 ENABLE: DO FILTER: DI FILTER: DI SEQUENCE OF OPERATION: 1. THE UNIT SHALL BE SCHEDULED AND INTERLOCKED TO THE HVAC EQUIPMENT SERVING THE SPACE 2. THE UNIT SHALL RUN WHEN THE OCCUPANCY IS SCHEDULED FOR THE EQUIPMENT AND BE OFF ALL OTHER TIMES. 3. ALARMS A. FILTER LOADED –SETPOINT RECOMMENDED BY THE VENDOR EXHAUST FAN STATUS: DI ENABLE: DO EFAN-1-2 THRU EFAN-1-5 OSOCCUPANCY SENSOR DI SEQUENCE OF OPERATION: 1. THE BMS SHALL CYCLE THE FAN ON UPON A SIGNAL FROM THE OCCUPANT SENSOR 2. 10 MINUTES AFTER THE LAST SIGNAL FROM THE OCCUPANCY SENSOR THE FAN SHALL TURN OFF. 3. ALARMS A. UNIT ON FOR MORE THAN 24 HOURS STRAIGHT B. OCCUPANCY SENSOR SIGNALLY OCCUPANCY FOR MORE THAN 24 HOURS DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTSPRELIMINARY SOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-M-v2020.rvt2/2/2022 7:25:15 PM405 100 0 AE 0054-17 JC JC TS I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MHS501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL HVAC CONTROL SCHEMATICS BRT-405-MHP500 NTS1TEMP CONTROLLED EXHAUST FAN - BMS SCHEMATIC NTS5ELECTRIC HEATER - BMS SCHEMATIC NTS3SPLIT AC UNIT - BMS SCHEMATIC SHEET NOTES: 1. BUILDING MANAGEMENT SYSTEMS TO BE NIAGARA TRIDIUM. 2. BMS CONTINUOUSLY MONITOR BUILDING ENVIRONMENTAL CONDITIONS AND EQUIPMENT OPERATION. 3. BMS COMPARES BUILDING ENVIRONMENTAL CONDITIONS AND EQUIPMENT OPERATION TO ACCEPTABLE BUILDING ENVIRONMENTAL VALUES AND OPERATING SCHEDULES. 4. BMS ACTIVATES OR DEACTIVATES BUILDING EQUIPMENT AS REQUIRED TO MAINTAIN ACCEPTABLE BUILDING ENVIRONMENTAL VALUES AND OPERATING SCHEDULES. 5. BMS REGISTERS FAULT SIGNALS FOR BUILDING EQUIPMENT UNABLE TO MAINTAIN ACCEPTABLE BUILDING ENVIRONMENTAL VALUES AND OPERATING SCHEDULES. 6. BMS COMMUNICATES FAULTS TO ST FACILITIES MAINTENANCE FOR GARAGES. 7. BMS MANAGES FIRE ALARM RESPONSE FOR MECHANICAL EQUIPMENT BASED ON FACP INPUT. 8. INSTRUMENTATION SHOWN FOR REFERENCE, BUT DESIGNER SHALL COORDINATE APPROPRIATE SENSOR OR INSTRUMENTATION FOR FUNCTIONALITY OF SELF-CONTROLLED EQUIPMENT AND BMS CONTROLLED EQUIPMENT. NTS4ENERGY RECOVERY VENTILATOR - BMS SCHEMATIC NTS2JANITOR'S CLOSET TOILET CEILING EXHAUST FAN - BMS SCHEMATIC SC SUPPLY/ OUTDOOR AIR RETURN / EXHAUST ERV-1-1 RENEWAIRE SL70H 60 60 SECURITY ROOM BTP120102 LACTATION ROOM BTP120103 0.50 0.50 8 8 24 57 83 78 72% 58%120/1 2 2 10 32 1,2 ENERGY RECOVERY VENTILATOR SCHEDULE NOTES: 1. ELECTRONICALLY COMMUTATED MOTOR (ECM). 2. PROVIDE WITH WALL MOUNT TC7D DIGITAL TIME CLOCK AND INSTALL IT IN SECURITY ROOM. EXT.S.P.(IN. WG.)EXT.S.P.(IN. WG.)OUTDOOREAT °FSUPPLYLAT °FOUTDOOREAT °FSUPPLYLAT °FWINTERSUMMERVOLTAGE /PHASEFLA(SUPPLY FAN)FLA(EXHAUST FAN)TOTAL MCADESIGNATION MANUFACTURER MODEL NUMBER MAXIMUM CFM SERVICE SUPPLY FAN EXHAUST FAN INTAKE FILTEREFFICIENCY(MERV)EXHAUST FILTEREFFICIENCY(MERV)WINTER SUMMER TOTAL EFFECTIVENESS ELECTRICAL OPERATING WEIGHT (LBS) NOTES NOTES: 1. PROVIDE WITH CONDENSATE PUMP AND ECM MOTOR. 2. HEAT PUMP UNIT. ACU-1-3 CU-1-3 SECURITY ROOM BTP120102 DAIKIN FTX09AXVJU WALL MOUNTED 430 0 9 8 75 63 55 54 13 0.3 FLA 208/1 N 20 1,2 ACU-1-4 CU-1-4 LACTATION ROOM BTP120103 DAIKIN FTX09AXVJU WALL MOUNTED 430 0 9 8 75 63 55 54 13 0.3 FLA 208/1 N 20 1,2 ACU-2-1 CU-2-1 COMMNUNICATOINS CLOSET BTP120201 DAIKIN FAQ24PVJU WALL MOUNTED 635 0 24 18 75 63 55 54 27 0.6 FLA 208/1 Y 31 1,2 ACU-2-2 CU-2-2 COMMNUNICATOINS CLOSET BTP120203 DAIKIN FAQ24PVJU WALL MOUNTED 635 0 24 18 75 63 55 54 27 0.6 FLA 208/1 Y 31 1,2 ACU-1-1 CU-1-1 ELEVATOR MACHINE ROOM BTP120101 DAIKIN FDMQ24RVJU HORIZONTAL DUCTED 800 0.4 24 17 75 63 55 54 27.6 1.54 208/1 Y 82 1,2 ACU-1-2 CU-1-2 COMMNUNICATIONS ROOM BTP120109 DAIKIN FAQ24PVJU WALL MOUNTED 635 0 24 18 75 63 55 54 27 0.6 FLA 208/1 Y 31 1,2 ACU-4-1 CU-4-1 COMMNUNICATOINS CLOSET BTP120401 DAIKIN FAQ24PVJU WALL MOUNTED 635 0 24 18 75 63 55 54 27 0.6 FLA 208/1 Y 31 1,2 ACU-4-2 CU-4-2 COMMNUNICATOINS CLOSET BTP120203 DAIKIN FAQ24PVJU WALL MOUNTED 635 0 24 18 75 63 55 54 27 0.6 FLA 208/1 Y 31 1,2 CAPACITY EAT LAT CAPACITY(MBH)MCAVOLTAGE / PHASETOTALMBHSENSIBLEMBHDB(°F)WB(°F)DB(°F)WB(°F)SPLIT SYSTEM INDOOR UNIT SCHEDULE DESIGNATION CORRESPONDING OUTDOOR UNIT SERVICE MANUF. MODEL NUMBER UNIT TYPE SUPPLY AIRFLOW (CFM) ESP (IN. WG.) COOLING HEATING ELECTRICAL STANDBY POWER (Y/N) WEIGHT (LBS)NOTES NOTES:MCA (A)VOLTAGE / PHASECU-2-1 ACU-2-1 DAIKIN RZR24PVJU R-410A 24 N/A 17.3 10.2 16.5 208/1 150 CU-2-2 ACU-2-2 DAIKIN RZR24PVJU R-410A 24 N/A 17.3 10.2 16.5 208/1 150 CU-1-1 ACU-1-1 DAIKIN RX24RMVJUA R-410A 24 15.0 18.6 12.5 16.9 208/1 108 CU-1-2 ACU-1-2 DAIKIN RZR24PVJU R-410A 24 N/A 17.3 10.2 16.5 208/1 150 CU-1-3 ACU-1-3 DAIKIN RX09AXVJU R-410A 9 N/A 19.0 12.5 8.7 208/1 57 CU-1-4 ACU-1-4 DAIKIN RX09AXVJU R-410A 9 N/A 19.0 12.5 8.7 208/1 57 CU-4-1 ACU-4-1 DAIKIN RZR24PVJU R-410A 24 N/A 17.3 10.2 16.5 208/1 150 CU-4-2 ACU-4-2 DAIKIN RZR24PVJU R-410A 24 N/A 17.3 10.2 16.5 208/1 150 SPLIT SYSTEM AIR COOLED CONDENSER OUTDOOR UNIT SCHEDULE DESIGNATION SERVICE MANUF. MODEL NUMBER REF COOLING CAPACITY (MBH) HEATING CAPACITY (MBH) SEER EER ELECTRICAL WEIGHT (LBS)NOTES RG-A TITUS 3FL RETURN SEE PLANS 1 SG-A TITUS 300-FL SIDEWALL SUPPLY SEE PLANS 1 AIR INLET AND OUTLET SCHEDULE NOTES: 1. COORDINATE FINAL DIFFUSER LOCATION, COLOR AND BORDER TYPE WITH ARCHITECT. DESIGNATION MANUFACTURER MODEL NUMBER SERVICE FACE DIMENSIONS REMARKS DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTSPRELIMINARY SOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-M-v2020.rvt2/2/2022 7:25:15 PM405 101 0 AE 0054-17 JC JC TS I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MHS502PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL HVAC SCHEDULES BRT-405-MHP500 SC EFAN-1-1 ELECTRICAL ROOM BTP120112 GREENHECK INLINE SQ140-VG 2000 0.5 3/4 120/1 NO YES 74 11.6 90 2 EFAN-1-2 WOMEN'S BTP120104 GREENHECK CEILING SP-A200 200 0.25 0.46FLA 120/1 NO NO 54 2 24 1 HP VOLTAGE/ PHASE VFD ECM EFAN-1-3 MEN'S BTP120106 GREENHECK CEILING SP-A200 200 0.25 0.46FLA 120/1 NO NO 54 2 24 1 EFAN-1-4 ALL GENDER BTP120105 GREENHECK CEILING SP-A110 100 0.25 0.18FLA 120/1 NO NO 45 0.7 17 1 EFAN-1-5 JAN RM BTP120107 GREENHECK CEILING SP-A110 100 0.25 0.18FLA 120/1 NO NO 45 0.7 17 1 EFAN-2-1 ELEC BTP120202 GREENHECK INLINE SQ90-VG 400 0.5 1/10 120/1 NO YES 67 8 49 2 EFAN-4-1 ELEC BTP120402 GREENHECK INLINE SQ90-VG 400 0.5 1/10 120/1 NO YES 67 8 49 2 NOTES: 1. FAN ON/OFF CONTROLLED BY LIGHTING SWITCH. 2. FAN ON/OFF CONTROLLED BY WALL THERMOSTAT. FAN SCHEDULE DESIGNATION LOCATION/SERVICE MANUFACTURER TYPE MODEL CFM STATIC PRESSURE IN. WC MOTOR LWA SONES WEIGHT NOTESKWEAT(°F)LAT(°F)HTR-1-1 ELEC RM BTP120112 REZNOR EGHB 510 3.0 70 89 1/30 208 / 1 1,2 HTR-1-2 SPRINKLER BTP120110 REZNOR EGHB 510 2.0 70 82 1/30 208 / 1 1,2 HTR-1-3 MENS BTP120106 REZNOR EHC 160 2.0 70 109 N/A 208 / 1 1,2 HTR-1-4 WOMENS BTP120104 REZNOR EHC 160 2.0 70 109 N/A 208 / 1 1,2 HTR-1-5 ALL GENDER BTP120105 REZNOR EHC 160 1.5 70 100 N/A 208 / 1 1,2 HTR-1-6 STORAGE BTP120108 REZNOR EGHB 510 2.0 70 82 1/30 208 / 1 1,2 HTR-1-7 JAN ROOM BTP120107 REZNOR EHC 160 2.0 70 109 N/A 208 / 1 1,2 HTR-1-8 PANELS ROOM BTP120111 REZNOR EHC 160 1.5 70 100 N/A 208 / 1 1,2 HTR-2-1 ELEC BTP120202 REZNOR EHC 160 2.0 70 109 N/A 208 / 1 1,2 HTR-4-1 ELEC BTP120402 REZNOR EHC 160 2.0 70 109 N/A 208 / 1 1,2 NOTES: 1. PROVIDE BUILT-IN THERMOSTAT KIT. 2. COORDINATE COLOR AND FINISH WITH ARCHITECT. ROOM HEATER SCHEDULE DESIGNATION SERVICE / LOCATION MANUF. MODEL NUMBER AIRFLOW (CFM) HEATING MOTOR HP VOLTAGE/ PHASE NOTES DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTSPRELIMINARY SOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-M-v2020.rvt2/2/2022 7:25:16 PM405 102 0 AE 0054-17 JC JC TS I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MHS503PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL HVAC SCHEDULES BRT-405-MHP500 SC GALVANIZED STEEL IRON RING (TYP.) GALVANIZED STEEL RECTANGULAR DUCTWORK GALVANIZED STEEL LATERAL ANGLE BRACE METAL DECK 7/16"Ø MACHINE BOLTS (TYP.) THREADED HANGER RODS (TYP.) COUPLING (TYP.) 1 3 GALVANIZED STEEL STRAP WRAP AROUND DUCTWORK (TYP.) SHEET METAL SCREW (TYP.)1 NOTES: 1. SIZES, QUANTITIES AND SPACING IN ACCORDANCE WITH MECHANICAL CODE REQUIREMENTS. 2. ROUND DUCT SUPPORT SIMILAR. 3.PROVIDE DUCTMATE OVALMATE IN PLACE OF ANGLE IRON EXCEPT AT SEISMIC BRACE. SECTION A-A 1/2" EXPANSION ANCHOR (3-1/2" MIN. EMBEDMENT, TYPICAL AT 2ND FLOOR) 45° A 45° 1 GALVANIZED STEEL IRON RING (TYP.) GALVANIZED STEEL ROUND DUCTWORK GALVANIZED STEEL LATERAL ANGLE BRACE AT 40'-0" SPACING. MIN. ONE PER MAIN DUCT 5/16"Ø MACHINE BOLTS (TYP.) THREADED HANGER RODS (TYP.) COUPLING (TYP.) 1 2 GALVANIZED STEEL STRAP WRAP AROUND DUCTWORK (TYP.) SHEET METAL SCREW (TYP.) 1 1 1 SIZES, QUANTITIES AND SPACING IN ACCORDANCE WITH MECHANICAL CODE REQUIREMENTS. 2 PROVIDE GALVANIZED IRON RING OR "OVALMATE" JOINT. SECTION A-A 1/2"Ø EXPANSION ANCHOR (3-1/2" MIN. EMBEDMENT, TYPICAL AT 2ND FLOOR) NOTES: 2 45° A 45° FLAT OVAL EQUIVALENT ROUND ROUND Ø FLAT OVAL INCHES 6" 4x9 7"5x10 8"6x11 10"6x11 12"7x20 14"8x22 16"8x30 ROLL WYE TOWARD DIFFUSER INLET NECK BALANCING DAMPER MAIN ROUND DUCT MAIN SUPPLY DUCT BALANCING DAMPER OVAL TO ROUND TRANSITION ADJUSTABLE SCREW TYPE STAINLESS STEEL CLAMP ROUND CONNECTION WITH 3/8" RAISED BEAD SAME DIAMETER AS FLEX CONNECTION. FLEXIBLE DUCT TO DIFFUSER FLAT OVAL, SEE SCHEDULE FOR EQUIVALENT ROUND SIZE MAIN SUPPLY DUCT SPIN-IN ROUND COLLAR WITH 3/8" RAISED BEAD & BALANCING DAMPER FLEXIBLE DUCT TO DIFFUSER FLEXIBLE DUCT TO DIFFUSER ROUND DUCT COLLAR WITH 3/8" RAISED BEAD AND BALANCING DAMPER ADJUSTABLE SCREW TYPE STAINLESS STEEL CLAMP ADJUSTABLE SCREW TYPE STAINLESS STEEL CLAMP "Y" LATERAL FITTING 45° ROUND TAP TO RECTANGULAR MAIN (TAP SMALLER THAN MAIN) ROUND TAP TO ROUND MAIN ROUND TAP TO RECTANGULAR MAIN (TAP LARGER THAN MAIN) BALANCING DAMPER NOTE 4 MAX. 2 1 1/8" ANGLE 1/2" CLEAR SEISMIC AIRCRAFT CABLE SPRING VIBRATION ISOLATOR HANGER ROD SUSPENDED EQUIPMENT DUAL U-BOLT CABLE CLAMPS CABLE EYELET LOCK NUT AND WASHER NOTES: 1. HANGER SPACING ALONG LENGTH OF UNIT TO BE AS FOLLOWS: MINIMUM - 2 HANGERS MAXIMUM SPACING 6'-0". 2. PROVIDE ADEQUATE SEISMIC CABLE BRACING TO RESIST MOTION IN ALL LATERAL DIRECTIONS. 3. REFER TO SMACNA SEISMIC RESTRAINT MANUAL GUIDELINES (LATEST EDITION) FOR MECHANICAL SYSTEMS. 4. ATTACH TO STRUCTURE ABOVE. FIXED AIR GAP BY PLUMBING CONTRACTOR 1"CONDENSATE DRAIN FROM MECHANICAL UNIT OR CONDENSATE PUMP. MECHANICAL CONTRACTOR TO CONNECT CONDENSATE PIPING TO FIXED AIR GAP FITTING PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR. P-TRAP2'-0" MAX.CEILING VENT NOTE: MAXIMUM ONE DRAIN CONNECTION AT EACH SINK. FLOOR SINK MECHANICAL SCOPE PLUMBING SCOPE INSULATED 7'-0" 6" 1/2" SUSPENSION BOLTS WALL MOUNTED AC UNIT ELEVATION FRONT VIEW WALL MOUNTED AC MOUNTED 6" ABOVE DOORRLG RLRSGAS PIPE SIZE = 5/8" OD LIQUID PIPE SIZE = 3/8 OD CONTRACTOR TO VERIFY INSTALLATION OF REFRIGERANT PIPING PER MANUFACTURES GUIDELINES MOUNTING DETAIL D INTEGRAL MOUNTING BRACKET INTEGRAL CONDENSING PUMP FLOOR DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTSPRELIMINARY SOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-M-v2020.rvt2/2/2022 7:24:53 PM405 103 0 AE 0054-17 JC JC TS I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MHD501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL HVAC DETAILS BRT-405-MHP500 NTS1DUCT SUPPORT DETAIL - A NTS2DUCT SUPPORT DETAIL - B NTS3LOW PRESSURE BRANCH DUCT CONNECTIONS NTS4SUSPENDED EQUIPMENT WITH SEISMIC CABLES - B NTS5CONDENSATE DRAIN CONNECTION TO SINK AIR GAP FITTING NTS6WALL MOUNTED AC D NPW TP FLOOR SINK RISER NO. RISER EQUIPMENT EQUIPMENT NO.EQUIPMENT DESIGNATION DWG. SHEET NO. DETAIL NUMBER REVISION NUMBER DOMESTIC COLD WATER PIPING NUMBERED NOTE NUMBER DETAIL DESIGNATION DOMESTIC HOT WATER PIPING DOMESTIC HOT WATER RETURN PIPING SLEEVE PUMP METER FLOOR DRAIN, AREA DRAIN, PLANT DRAIN, GARAGE DRAIN ROOF DRAIN ROOF RECEPTOR HOSE BIBB PLUMBING LEGEND AND ABBREVIATIONS TRAP PRIMER NON-POTABLE WATER LEGEND (CONTINUED) WATER HAMMER ARRESTER RISE (WITH IN FLOOR)RISEGARAGE DRAINGD EXPANSION LOOP SIZE FLEXIBLE CONNECTION CUBIC FEET PER SECONDCFS CUBIC FEET PER MINUTECFM SHOWERSH ROOF RECEPTORRR EXPANSION TANKET DRINKING FOUNTAINDF ACCESS PANELAP MH MIN MS (N) NC NORMALLY CLOSED NEW MOP SINK MINIMUM MANHOLE OS&Y P/FT PD POC PDR PLANTER DRAIN POINT OF CONNECTION PITCH PER FOOT PUMP DISCHARGE OUTSIDE SCREW & YOKE GATE VALVE NOT IN THIS CONTRACTNIC PSI PSIG RC SD SE SF SED SEWAGE EJECTOR DISCHARGE SQUARE FEET SMOKE DETECTOR SEWAGE EJECTOR POUNDS PER SQUARE INCH (GAUGE) ROOF RECEPTOR POUNDS PER SQUARE INCH PRESSURE REDUCING VALVEPRV Y STRAINER WITH BLOW OFF VALVE LEGEND PRESSURE REDUCING VALVE OS&Y (OUTSIDE SCREW & YOKE) VALVE VALVE (SPECIFICATION FOR TYPE) CHECK VALVE BALANCING VALVE SOLENOID VALVE UNION PRESSURE GAUGE AND COCK TEMPERATURE MIXING VALVE VALVE WITH TAMPER SWITCH AD BLDG AFF BOB CD BV BOP ABOVE FINISHED FLOOR BOTTOM OF PIPE BALANCING VALVE CONDENSATE DRAIN BOTTOM OF THE BEAM AREA DRAIN BUILDING CLG COTG CONN CONT CP CLEANOUT TO GRADE CONTINUATION CIRCULATING PUMP CEILING CONNECTION CV CW DN DWG DWP DR CHECK VALVE COLD WATER DOWN DRAIN DRAWING EL (E) EWC EWH FCO FD ELEVATION ELECTRIC WATER COOLER FLOOR CLEANOUT ELECTRIC WATER HEATER FLOOR DRAIN EXISTING DOMESTIC WATER PUMP FL FLOOR FSK FT FU FIXTURE UNIT FLOOR SINK FEET GAL GPM GALLONS PER MINUTE GALLONS CFH CUBIC FEET PER HOUR CO CLEANOUT FS FLOW SWITCH NPW NON-POTABLE WATER BUTTERFLY VALVE (MANUAL) GLOBE VALVE SEISMIC JOINT THERMOMETER WATER FLOW SWITCH DFU DRAINAGE FIXTURE UNIT SAN SANITARY RISER DESIGNATION FLOOR NO. (H)(X)(L) M BT BATHTUB CA COMPRESSED AIR CI CAST IRON DIA DIAMETER DROP (WITHIN FLOOR)DROP EMERGENCY EYE WASHEEW FLH FLOOR HYDRANT NORMALLY OPENNO OD OUTSIDE DIAMETER OFD OVERFLOW DRAIN OST OVERFLOW STORM PIPING PIV POST INDICATING VALVE RD ROOF DRAIN RECLAIMED WATERRW SHOCK ABSORBERSA SHOCK ABSORBER VACUUM BREAKER MANUAL AIR VENT AUTOMATIC AIR VENT BASKET STRAINER CHECK VALVE WITH ABD AUTOMATIC FLOW CONTROL VALVE RELIEF VALVE ANGLE RELIEF VALVE REDUCER ECCENTRIC REDUCER (E.R.) IRRIGATION PIPINGIRR M A OVERFLOW ROOF DRAIN ? ? X # X X-X X ? POTABLE WATER NON-POTABLE / INDUSTRIAL WATER MISCELLANEOUS LDR MAX MAXIMUM LEADER LAVATORYL JS JANITOR SINK kPa KILOPASCALS LPS LITERS PER SECOND M METERS M²SQUARE METERS M³CUBIC METERS mm MILLIMETER VALVE IN VERTICAL BOTTOM PIPE CONNECTION TOP PIPE CONNECTION PIPING LEGEND V SEV SPV SED SPD CD IW ST SAN SAN SUMP PUMP VENT PIPING INDIRECT WASTE PIPING VENT PIPING SANITARY (ABOVE FLOOR) SEWAGE EJECTOR VENT PIPING SEWAGE EJECTOR DISCHARGE PIPING SUMP PUMP DISCHARGE PIPING SANITARY (BELOW FLOOR) CONDENSATE DRAIN PIPING STORM DRAIN PIPING OVERFLOW STORM PIPINGOST WASTE / VENT / STORM GD GD GARAGE DRAIN PIPING (BELOW FLOOR) GARAGE DRAIN PIPING (ABOVE FLOOR) CENTER LINEC CLEANOUT/PLUG PIPE UP P-TRAP PIPE DOWN FLOOR CLEANOUT/GRADE CLEANOUT CHANGE IN PIPE ELEVATION ARROW INDICATES DIRECTION OF FLOW PITCH PIPE DOWN IN DIRECTION OF ARROW CAP INSULATED AND HEAT TRACED PIPING FRESH AIR INLET WALL HYDRANT SSD SSD SUB-SOIL DRAIN (BELOW FLOOR) SUB-SOIL DRAIN (ABOVE FLOOR) PUMP DISCHARGEPD ABBREVIATIONS TOTAL DISCHARGE HEADTDH SUB SOIL DRAINSSD TEMPERATURE MIXING VALVETMV TRENCH DRAINTD TRAP PRIMER VALVETPV SK SINK SPKR SP TOP ST TYP TS UP UR UON TOS TOP OF SLAB UP (PENETRATES FLOOR SLAB) UNLESS OTHERWISE NOTED URINAL TAMPER SWITCH TYPICAL STORM PIPING TOP OF PIPE SUMP PUMP SPRINKLER SPD SUMP PUMP DISCHARGE VB VTR WH Z WC WATER CLOSET WALL HYDRANT ZONE VENT THROUGH ROOF VACUUM BREAKER VENTV SOI SAND/OIL INTERCEPTOR SUMP PUMP VENTSPV TRAP PRIMERTP VR VENT RISE WHA WATER HAMMER ARRESTER WFU WATER FIXTURE UNIT HD HUB DRAIN HT HW HB HEAT TRACING HOSE BIBB HOT WATER HWR HOT WATER RETURN HWCP HOT WATER CIRCULATING PUMP INCHIN INVERT ELEVATIONIE IW INDIRECT WASTE HEAT EXCHANGERHX ID INSIDE DIAMETER GV GATE VALVE ABBREVIATIONSABBREVIATIONS DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTSPRELIMINARY SOUTH RENTON TRANSIT CENTERML02/11/2022 02/11/2022 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-P-v2020.rvt2/3/2022 1:45:30 PM405 104 0 AE 0054-17 BW BW Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MPN500PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL PLUMBING LEGENDS AND ABBREVIATIONS BRT-405-MPN500 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 2" CW FROM RPBP, SEE SITE PLAN FOR CONTINUATION 6" SAN, SEE SITE PLAN FOR CONTINUATION UP TO FCO UP TO FCO 6" ST FROM ABOVE 6" ST FROM ABOVE UP TO GD-1 UP TO GD-1 UP TO GD-1 UP TO GD-1 UP TO GD-1 UP TO GD-1 8" ST, SEE SITE PLAN FOR CONTINUATION SOI 1 6" GD6" GD 6" GD6" GD6" GD 6" GD 6" GDN DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/2022 02/11/2022 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-P-v2020.rvt2/3/2022 1:45:32 PM1/16" = 1'-0" 405 105 0 AE 0054-17 BW BW Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MPP501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL PLUMBING PLAN - LEVEL B1 SCALE: 1/16" = 1'-0"405-MPP501 PLUMBING - B1 PLAN 1 BRT-405-MPP500 BTP120105 BTP120104 ELEV#2 ELEV#1 BTP120106 BTP120101 BTP120109 BTP120107 BTP120102 BTP120103 BTP120108 BTP120110 BTP120111 BTP120112 BTP120113 STR#1 STR#2 FS-1 WH-1 S-1 L-1 FD-1 WC-2 L-2 WC-1 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 MS-1 WC-2 FD-1 UR-1 L-1 HEAT TRACE CW PASSING THROUGH UNCONDITIONED SPACE 2" CW DN W/SHUT- OFF VALVE 6" GD-1 TYP. EEW-1 HEAT TRACE CW PASSING THROUGH UNCONDITIONED SPACE FCO 6" ST UP & DN 6" ST FROM ABOVE 6" ST FROM ABOVE 6" ST DN FCO 4" GD DN 4" GD DN 4" GD DN 4" GD DN 4" GD DN 4" GD DN SOI 1 N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTEDPRELIMINARY SOUTH RENTON TRANSIT CENTERML02/11/2022 02/11/2022 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-P-v2020.rvt2/3/2022 1:45:34 PM405 106 0 AE 0054-17 BW BW Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MPP502 MECHANICAL PLUMBING PLAN - LEVEL 1 SHEET NOTES: 1.PROVIDE VENTING PER CODE FOR SAND/OIL INTERCEPTOR, SOI-1. 2.ROUTE CONDENSATE FROM FAN COIL UNITS TO JANITOR'S ROOM, SPILL TO SINK AND MOP SINK. REFER TO MECHANICAL DWG. FOR LOCATION OF FAN COILS. SCALE: 1/16" = 1'-0"405-MPP502 PLUMBING PLAN - LEVEL 1 & 1.5 1 BRT-405-MPP500 ELEV#2 ELEV#1 BTP120202 BTP120201 BTP120203 UP4.2% UP4.2% STR#2 STR#1 UP TO LEVEL 3 DOWN TO LEVEL 1.5 UP TO LEVEL 2.5 UP TO LEVEL 2.5 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 4" GD-1 4" GD-1 6" ST FROM ROOF DRAINS 4" GD-1 4" GD-1 4" GD-1 4" GD-1 6" ST FROM ROOF DRAINS 6" ST FROM ROOF DRAINS 6" ST FROM ROOF DRAINS N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/2022 02/11/2022 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-P-v2020.rvt2/3/2022 1:45:38 PM1/16" = 1'-0" 405 107 0 AE 0054-17 BW BW Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MPP503PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL PLUMBING PLAN - LEVEL 2 SCALE: 1/16" = 1'-0"405-MPP503 PLUMBING PLAN - LEVEL 2 & 2.5 1 SHEET NOTES: 1.LEVEL 2 GARAGE DRAIN LAYOUT TYPICAL, LEVELS 3 & 4 SIMILAR. 2.COORDINATE SLAB PENETRATIONS WITH STRUCTURAL. BRT-405-MPP500 ELEV#2 ELEV#1 UP4.2% UP4.2% STR#1 STR#2 DOWN TO LEVEL 4.5 UP TO LEVEL 5.5 UP TO LEVEL 5.5 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 4" RD-1 TYP. 4" RD-1 TYP. N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/2022 02/11/2022 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-P-v2020.rvt2/3/2022 1:45:41 PM1/16" = 1'-0" 405 108 0 AE 0054-17 BW BW Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MPP506PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL PLUMBING PLAN - LEVEL 5 SCALE: 1/16" = 1'-0"405-MPP506 PLUMBING PLAN - LEVEL 5 & 5.5 1 SHEET NOTES: 1.COORDINATE SLAB PENETRATIONS WITH STRUCTURAL. BRT-405-MPP500 ROOF LEVEL 5 LEVEL 4 LEVEL 3 LEVEL 2 LEVEL 1 LEVEL B1 TO SANITARY SEWER TO STORM WATER SYSTEM FCO FCO 4" RD-1 4" RD-1 4" RD-1 4" GD-1, TYPICAL FLOORS 4 THROUGH 2ST GDSTSTSTSTSTSTSTSTST ST ST STGDGDGDGDGDGDGDGDGDGDGDGDGDGDGDGDGDGD GDGD GD GD GD GD 6" GD-1 6" GD-1 6" GD-1 SOI 1 N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTSPRELIMINARY SOUTH RENTON TRANSIT CENTERML02/11/2022 02/11/2022 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-P-v2020.rvt2/3/2022 1:45:41 PMNTS 405 109 0 AE 0054-17 BW BW Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MPS501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL PLUMBING RISER BRT-405-MPS500 S V CW HW WC-1 WATER CLOSET 4" 2" 1" -WALL HUNG WC-2 WATER CLOSET 4" 2" 1" -WALL HUNG, ADA L-1 LAVATORY 1-1/2" 1-1/2" 1/2" 1/2"NOTE 1 L-2 LAVATORY 1-1/2" 1-1/2" 1/2" 1/2" WALL HUNG, ADA, NOTE 1 S-1 SINK 2" 1-1/2" 1/2" 1/2"NOTE 1 MS-1 MOP SINK 3" 1-1/2" 1/2" 1/2"NOTE 2 EEW-1 EMERGENCY EYE WASH 2" 1-1/2" 1/2" 1/2" WALL HUNG, WITH BOWL & THERMOSTATIC MIXING VALVE WH-1 WALL HYDRANT _ _ 3/4" _ EXTERIOR WALL HYDRANT, NON-FREEZE NOTES: 1. PROVIDE ELECTRIC POINT OF USE WATER HEATER, INSTALL BELOW COUNTER 2. PROVIDE ELECTRIC WATER HEATER, INSTALL ON WALL SHELF ABOVE MOP SINK. PLUMBING FIXTURE SCHEDULE ITEM DESCRIPTION CONNECTIONS REMARKS 2. 1" AIR GAP REQUIRED AT ALL INSTANCES OF AN INDIRECT DRAIN DISCHARGING TO A FLOOR DRAIN/FLOOR SINK. PROVIDE UNISTRUT OR SIMILAR PIPE SUPPORT AS NECESSARY TO GUARANTEE REQUIRED AIR GAP. FD-1 FLOOR DRAIN 2" JR SMITH 2005Y FULL ROUND TOP, NOTE 1 GD-1 GARAGE DRAIN SEE DWGS. JR SMITH 1416Y HEAVY DUTY TRACTOR ROUND TOP, 15-1/4" DIA. HD-1 HUB DRAIN SEE DWGS. - - - P-TRAP W/STANDPIPE FS-1 FLOOR SINK 4" JR SMITH 3100Y-21 HALF NOTE 1 RD-1 ROOF DRAIN SEE DWGS. JR SMITH 1416Y HEAVY DUTY TRACTOR ROUND TOP, 15-1/4" DIA. NOTES: 1. PROVIDE TRAP PRIMER CONNECTION. PLUMBING DRAIN SCHEDULE TYPE DESCRIPTION SIZE MANUFACTURER MODEL NUMBER GRATE NOTES INLET OUTLET VENT SOI-1 SAND OIL INTERCEPTOR GARAGE DRAINS 5 GPM MAX 20 6 6 3 TBD INTERMITTENT FLOW PLUMBING SAND OIL INTERCEPTOR SCHEDULE NOTES: 72" L X 48" W, HEIGHT AS REQUIRED BY INSTALLATION. ITEM DESCRIPTION LOCATION & SERVICE FLOW RATE GALLONS WATER CAPACITY GALLONS CONNECTIONS INCHES MANUF. & MODEL NO. REMARKS DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTSPRELIMINARY SOUTH RENTON TRANSIT CENTERML02/11/2022 02/11/2022 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-P-v2020.rvt2/3/2022 1:45:41 PM405 110 0 AE 0054-17 BW BW Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MPS502PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL PLUMBING SCHEDULES BRT-405-MPS500 NAS NO AUTOMATIC SPRINKLERS OFI RN S.F. SPR PSI NTS OFCI NO NC NIC HYD INV OWNER FURNISHED AND INSTALLED POUNDS PER SQUARE INCH RISER NIPPLE SQUARE FEET SPRINKLER OWNER FURNISHED AND CONTRACTOR INSTALLED NOT IN CONTRACT NOT TO SCALE NORMALLY CLOSED NORMALLY OPEN INVERT OF PIPE ELEVATION HYDRANT GPM GC FEC FLR FFE FPC ELL EL DWG EM AFF CONT. CONTR. CLG AFC CONN AP FIRE PROTECTION CONTRACTOR HIGH/LOW AIR PRESSURE SWITCH FINISHED FLOOR ELEVATION FURNITURE EQUIPMENT CONTRACTOR GALLONS PER MINUTE GENERAL CONTRACTOR FLOOR EQUIPMENT MANUFACTURER ELEVATION ELBOW DRAWING ABOVE FINISHED FLOOR ABOVE FINISHED CEILING CONTINUATION CONTRACTOR CEILING CONNECTION ACCESS PANEL ACOUSTICAL TILE CEILINGATC ABBREVIATIONS -FIRE PROTECTION JOCKEY PUMP CONTROLLER FPCR FCC ATS FLOOR CONTROL VALVE ASSEMBLY AUTOMATIC TRANSFER SWITCH FIRE PUMP CONTROLLER JPC DN DOWN TOP WTS TYP TS TOP OF PIPE ELEVATION TAMPER / SUPERVISORY SWITCH WATER TIGHT SLEEVE TYPICAL SYMBOL LEGEND FS PS TH FSP D SP F FDC STRAINER PIPE PITCH ( INCHES PER FOOT) PIPING FLOW ARROW PRESSURE GAUGE PRESSURE SWITCH FLOW SWITCH UNION PIPING UP OR DN THROUGH FLOOR SLAB PIPING RISE OR DROP NOT THROUGH FLOOR SLAB DOUBLE CHECK VALVE ASSEMBLY PIPING BRANCH TAKE-OFF PIPE SLEEVE WATER TIGHT PIPE SLEEVE SHUTOFF VALVE FIRE DEPARTMENT CONNECTION PIPING FIRE PUMP TEST HEADER PIPING CHECK VALVE WITH BALL DRIP SHUTOFF VALVE WITH TAMPER SWITCH FIRE STANDPIPE PIPING DRAIN PIPING EXISTING TO REMAIN (GENERAL) EXISTING PIPING TO BE REMOVED (GENERAL) CONNECT TO EXISTING PIPING (GENERAL) WET SPRINKLER PIPING FIRE MAIN PIPING NEW PIPING (GENERAL) REDUCED PRESSURE BACKFLOW PREVENTER SWING CHECK VALVE DCVA RPBP CUT AND CAP EXISTING PIPING (GENERAL) . . INSULATED AND HEAT TRACED PIPING CONTINUATION PIPING LEGEND SECTION DESIGNATION DETAIL / SCHEMATIC DESIGNATION SPRINKLER HYDRAULIC NODE TAG UPRIGHT SPRINKLER HEAD HORIZONTAL SIDEWALL SPRINKLER HEAD CONCEALED PENDENT SPRINKLER HEAD SEMI-RECESSED PENDENT SPRINKLER HEAD PIPE CAP # # DWG EQUIPMENT TAG RISER DIAGRAM DESIGNATIONF # FIRE PUMP TEST HEADER FIRE DEPARTMENT CONNECTION (FLUSH) FIRE HOSE VALVE 24 VDC ELECTRIC BELL FIRE DEPARTMENT CONNECTION (FREE STANDING) PREACTION VALVE DRY PIPE VALVE ROOF MANIFOLD FIRE HOSE VALVE CABINET 2 WAY-FLUSH OUTLET BODY 3 WAY-FLUSH PLATE # DWG EQ # DSP DRY SPRINKLER PIPING WATER FLOW PRESSURE SWITCH WATER FLOW SWITCH HVAC HEATING VENTILATION AND AIR CONDITIONING CONTRACTOR PS WF/PS WF FHV FIRE HOSE VALVE INSPECTORS TEST VALVE FIRE PROTECTION LEGEND AND ABBREVIATIONS FCVA FIRE COMMAND CENTER FDC FIRE DEPARTMENT CONNECTION N NOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-FP-v2020.rvt2/8/2022 8:58:54 AMNTS 405 111 0 AE 0054-17 INL INL MJA I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MFN501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL FIRE PROTECTION LEGENDS AND ABBREVIATIONS BRT-405-MFN500 FIRE PROTECTION SHEET LIST SHEET NUMBER SHEET NAME 405-MFN501 FIRE PROTECTION LEGENDS AND ABBREVIATIONS 405-MFN502 FIRE PROTECTION GENERAL NOTES 405-MFP501 FIRE PROTECTION PLAN - LEVEL 1 405-MFP502 FIRE PROTECTION PLAN - LEVEL 2 405-MFP503 FIRE PROTECTION PLAN - LEVEL 3 405-MFP504 FIRE PROTECTION PLAN - LEVEL 4 405-MFP505 FIRE PROTECTION PLAN - LEVEL 5 405-MFD501 FIRE PROTECTION DETAILS FIRE PROTECTION GENERAL NOTES 1.PROVIDE AUTOMATIC DRY-PIPE SPRINKLER SYSTEMS AND A CLASS I MANUAL DRY STANDPIPE SYSTEM THROUGHOUT THE RENTON PARKING GARAGE BUILDING, HEREINAFTER REFERRED TO AS “THE FACILITY”. PROVIDE A NITROGEN GENERATOR FOR DRY SPRINKLER AND STANDPIPE SYSTEM. DO NOT USE COMPRESSED AIR. 2.CONTRACTOR SHALL CONDUCT A FIRE HYDRANT WATER SUPPLY TEST.IF MUNICIPAL WATER SUPPLY IS NOT ADEQUATE FOR SPRINKLER SYSTEMS, PROVIDE A FIRE PUMP TO SUPPLEMENT THE MUNICPAL WATER SUPPLY. 3.CONTRACTOR SHALL BE RESPONSIBLE FOR CONDUCTING A FIRE HYDRANT FLOW TEST, PREPARING SHOP DRAWINGS FOR AHJ REVIEW AND FOR FURNISHING AND INSTALLING ALL MATERIALS AND EQUIPMENT REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM AS DESCRIBED IN THE PROJECT SPECIFICATIONS AND THESE DRAWINGS. 4.APPLICABLE CODES AND REGULATIONS: ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING CODES AND REGULATIONS: •NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2016 EDITION •NFPA 14, STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEMS, 2016 EDITION •NFPA 20, STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION, 2016 EDITION •NFPA 88A, STANDARD FOR PARKING STRUCTURES, 2015 EDITION •2018 STATE BUILDING CODE; BUILDING CODE •2018 STATE BUILDING CODE; FIRE PREVENTION CODE •THE MANUFACTURER'S REQUIREMENTS •OTHER REFERENCED CODES AND STANDARDS, AS APPLICABLE 5.ALL REFERENCES TO THE ENGINEER SHALL MEAN WSP. ALL REFERENCES TO THE OWNER SHALL MEAN THE SOUTH RENTON TRANSIT CENTER. ALL REFERENCE TO THE AHJ SHALL MEAN THE CITY OF RENTON. 6.SPRINKLER SPACING AND HYDRAULIC DESIGN CRITERIA HAS BEEN DETERMINED BY NFPA 13 FOR THE HAZARD PROTECTED. SPRINKLER SYSTEMS MUST BE DESIGNED USING HYDRAULIC CALCULATIONS. THE FOLLOWING DESIGN CRITERIA APPLIES: •RESTROOMS AND SECURITY ROOMS, AND SIMILAR AREAS –LIGHT HAZARD: 0.10 GPM/SQ.FT OVER 1,500 SQ.FT, WITH A 100 GPM HOSE STREAM ALLOWANCE. K-5.6 SPRINKLERS. •PARKING GARAGE, MECHANICAL, ELECTRICAL AND STORAGE ROOMS –ORDINARY HAZARD GROUP 1: 0.15 GPM SQ FT OVER 2,535 SQ FT, WITH A 250 GPM HOSE STREAM ALLOWANCE. K-8.0 SPRINKLERS. •GENERATOR ROOM-EXTRA HAZARD GROUP 1: 0.3 GPM SQ FT OVER ENTIRE ROOM, WITH A 500 GPM HOSE STREAM ALLOWANCE. K-8.0 SPRINKLERS. 7.ALL WORK SHALL BE COORDINATED WITH THE OWNER. 8.ALL MATERIALS SHALL BE LISTED BY UNDERWRITERS LABORATORIES, INC. (U.L.) AND/OR FM APPROVED FOR USE ON COMMERCIAL FIRE PROTECTION SYSTEMS. 9.SPRINKLER TYPES: •INTERIOR AREAS WITH FINISHED CEILINGS: QUICK RESPONSE, STANDARD SPRAY, SEMI-RECESSED DRY PENDENT, ORDINARY TEMPERATURE, WHITE WITH WHITE ESCUTCHEON PLATE. •INTERIOR AREAS WITH UNFINISHED CEILINGS: STANDARD SPRAY, UPRIGHT, TEMPERATURE RATING AS REQUIRED BY ROOM PROTECTED, WITH BRASS FINISH. 10.SPRINKLER PIPE AND FITTINGS SHALL MEET THE FOLLOWING CRITERIA: •PIPE SIZES 2" AND SMALLER: SCHEDULE 40, BLACK STEEL, MEETING ASTM A53 (TYPE E GRADE B) OR A795 (TYPE E GRADE A) SPECIFICATIONS, CONNECTED WITH THREADED FITTINGS. •PIPE SIZES 2-1/2" AND LARGER: SCHEDULE 10, BLACK STEEL, MEETING ASTM A135 OR A795 TYPE E GRADE A SPECIFICATIONS, CONNECTED WITH LISTED GROOVED COUPLINGS. •THREADED FITTINGS FOR SCHEDULE 40 PIPE SHALL CONFORM WITH NFPA 13. •ROLL-GROOVED FITTINGS FOR SCHEDULE 10 PIPE SHALL BE UL LISTED. COUPLINGS SHALL COMPLY WITH ASTM A536, AND A183 SPECIFICATIONS WITH GRADE E, TYPE A GASKETS. ALL COMPONENTS SHALL BE FROM A SINGLE MANUFACTURER. •COUPLINGS AND GASKETS SHALL BE UL LISTED AND FM APPROVED FOR USE ON DRY PIPE SYSTEMS. PROVIDE A NITROGEN GENERATOR IN LIEU OF COMPRESSED AIR FOR DRY SYSTEMS. 11.ALL PIPING INSTALLED IN FINISHED AREAS SHALL BE INSTALLED CONCEALED UNLESS OTHERWISE APPROVED BY THE OWNER. 12.ALL NECESSARY CONNECTIONS TO THE FIRE ALARM SYSTEM SHALL BE MADE BY AND COORDINATED WITH THE FIRE ALARM CONTRACTOR. 13.AUXILIARY DRAINS ARE NOT SHOWN ON THESE DRAWINGS. LOCATIONS OF AUXILIARY DRAINS SHALL BE DETERMINED BY THE CONTRACTOR; WHERE A CHANGE IN PIPING DIRECTION PREVENTS DRAINAGE OF THE SYSTEM PIPING THROUGH THE MAIN DRAIN VALVE. SIGNS SHALL BE PROVIDED TO INDICATE AUXILIARY DRAIN LOCATIONS. 14.UPON COMPLETION OF THE NEW SYSTEM INSTALLATION, HYDROSTATIC TESTING SHALL BE CONDUCTED IN ACCORDANCE WITH NFPA 13 AND WITNESSED BY THE AHJ. 15.ALL SPRINKLER WORK SHALL BE INSPECTED BY A REPRESENTATIVE OF THE AHJ. 16.ALL DRY PIPE SYSTEMS SHALL BE PITCHED PER THE REQUIREMENTS OF NFPA 13. 17.ALL HANGERS SHALL BE U.L. LISTED FOR USE WITH SPRINKLER SYSTEMS. HANGER INSTALLATION AND SPACING SHALL BE IN ACCORDANCE WITH NFPA 13. 18.PROVIDE SEISMIC BRACING. SPRINKLER AND STANDPIPE SYSTEM PIPING SHALL WITHSTAND THE EFFECTS OF MOTIONS AS DETERMINED ACCORDING TO NFPA 13 AND ASCE/SEI7. 19.DRY PORTIONS OF SPRINKLER AND STANDPIPE SYSTEM SHALL BE SUPPLIED BY A NITROGEN GENERATOR. PROVIDE EMERGENCY POWER FOR AIR COMPRESSOR THAT SUPPLIES NITROGEN GENERATOR. AIR COMPRESSOR MUST HAVE A HARD WIRED CONNECTION AND HAVE OVERLOAD PROTECTION. COORDINATE FINAL NITROGEN GENERATOR REQUIREMENTS WITH ELECTRICAL CONTRACTOR BASED ON SYSTEM VOLUME AND ESTIMATED FILL TIME AS DETERMINED BY CALCULATIONS. COORDINATE WITH ALL TRADES TO ALLOW ADEQUATE CLEARANCES PROVIDE NITROGEN GENERATOR FOR FILLING THE DRY PORTION OF THE SPRINKLER SYSTEM. STORAGE TANKS WILL NOT BE ACCEPTABLE IN LIEU OF A NITROGEN GENERATOR. THE FIRE PROTECTION CONTRACT DRAWINGS ARE THE "PRELIMINARY PLANS" DEFINED BY NFPA 13, A.14.1 PREPARED FOR PRELIMINARY SUBMISSION TO THE AUTHORITIES HAVING JURISDICTION TO OBTAIN A PERMIT. THE CONTRACT DRAWINGS INDICATE A PARTIAL DESIGN AND SPECIFY THE DESIGN CRITERIA TO BE USED BY THE INSTALLING CONTRACTOR WHO FINALIZES THE SYSTEM LAYOUT AND PROVIDES HYDRAULIC CALCULATIONS. THE PRELIMINARY PLANS ONLY SHOW THE "TENTATIVE LOCATION OF MAJOR PIPING INCLUDING MAINS, RISERS, OVERHEAD MAINS AND FIRE DEPARTMENT CONNECTIONS." THE SPRINKLER AND PIPING LAYOUTS AND PIPE SIZES SHOWN ON THE CONTRACT DRAWINGS ARE TO DEFINE THE BASIC SCOPE FOR PERMITTING AND ARE NOT INTENDED TO BE COMPLETE TAKE OFF BID DOCUMENTS FOR COMPETITIVE BIDDING. THE DRAWINGS ARE DIAGRAMMATIC AND SHALL BE USED IN CONJUNCTION WITH THE SPECIFIED REQUIREMENTS TO PROVIDE COMPLETE, FULLY FUNCTIONAL AND CODE COMPLIANT SYSTEMS. THE SCOPE OF WORK OF THE FIRE PROTECTION CONTRACT INCLUDES: •PREPARATION OF WORKING (FABRICATION) DRAWINGS AS DEFINED BY NFPA 13. •COMPLETE SPRINKLER PROTECTION IN COMPLIANCE WITH NFPA 13. •COMPLETE STANDPIPE SYSTEMS IN COMPLIANCE WITH NFPA 14. •HYDRAULIC CALCULATIONS FOR THE ACTUAL INSTALLATION CONDITIONS BASED ON THE COORDINATION DRAWINGS. •COORDINATION WITH OTHER TRADES. •ON SITE FIELD SURVEY, MEASUREMENT, DESIGN AND FABRICATION. •HYDRANT FLOW TESTING IN ACCORDANCE WITH NFPA 291 TO CONFIRM AVAILABLE WATER SUPPLY. SPRINKLER WORK NOTES *ALL SPRINKLERS ARE TO BE QUICK RESPONSE WHERE ALLOWED. LIGHT HAZARD: -DENSITY=0.1 GPM/S.F. FOR MOST REMOTE 1,500 S.F. WITH 100 GPM HOSE STREAM -SPRINKLER COVERAGE 225 S.F. (MAX.) ORDINARY HAZARD, GROUP I: -DENSITY=0.15 GPM/S.F. FOR MOST REMOTE 1,500 S.F. WITH 250 GPM HOSE STREAM -SPRINKLER COVERAGE 130 S.F. (MAX.) ORDINARY HAZARD, GROUP II: -DENSITY=0.2 GPM/S.F. FOR MOST REMOTE 1,500 S.F. 1,950 S.F FOR DRY SYSTEMS. WITH 250 GPM HOSE STREAM -SPRINKLER COVERAGE 130 S.F. (MAX.) EXTRA HAZARD, GROUP I: -DENSITY=0.3 GPM/S.F. FOR MOST REMOTE 2,500 S.F. WITH 500 GPM HOSE STREAM -SPRINKLER COVERAGE 100 S.F. (MAX.) EXTRA HAZARD, GROUP II: -DENSITY=0.4 GPM/S.F. FOR MOST REMOTE 2,500 S.F. WITH 500 GPM HOSE STREAM -SPRINKLER COVERAGE 100 S.F. (MAX.) *ALL HYDRAULIC CALCULATIONS SHALL INCLUDE AN INSIDE HOSE STREAM ALLOWANCE OF 100 GPM AT HOSE VALVE CONNECTIONS. SPRINKLER DESIGN CRITERIA 1. 2. FIRE PROTECTION NOTES LIGHT HAZARD CRITERIA ASSUMED, UNLESS NOTED OTHERWISE. ORDINARY HAZARD, GROUP I: LABELED ORDINARY HAZARD, GROUP II: LABELED EXTRA HAZARD, GROUP I: LABELED EXTRA HAZARD, GROUP II: LABELED REFER TO NFPA 13 FOR SPRINKLER SYSTEM REQUIREMENTS BASED ON HAZARD. SPRINKLER HAZARD LEGEND OH2 OH1 EH1 EH2 N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-FP-v2020.rvt2/8/2022 8:58:54 AMNTS 405 112 0 AE 0054-17 INL INL Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MFN502PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL FIRE PROTECTION GENERAL NOTES BRT-405-MFN500 DRY VALVE ASSEMBLY SCHEDULE EQUIPTMENT TAG ELECTRICAL EQUIPTMENT REMARKS TYPE # VOLT AGE TEXT PHA SE H P RPM DV 1 120 1 1 1700 PRE-FABRICATED DRY VALVE PACKAGE SUPPLIED BY A NITROGEN GENERATOR. THE PACKAGE SHALL BE UL LISTED. DRY VALVE SERVE THE GARAGE ON LEVEL 1. PROVIDE EMERGENCY POWER FOR AIR COMPRESSORS. CONTRACTOR TO COORDINATE FINAL AIR COMPRESSOR REQUIREMENTS WITH ELECTRICAL CONTRACTOR BASED ON SYSTEM VOLUME AND ESTIMATED FILL TIME AS DETERMINED BY THEIR CALCULATIONS. COORDINATE WITH ALL TRADES TO ALLOW ADEQUATE CLEARANCES. PROVIDE NITROGEN GENERATOR TO SUPPLY DRY PIPE SYSTEMS IN LIEU OF COMPRESSED AIR. NITROGEN GENERATOR HAS THE FOLLOWING ELECTRICAL CHARACTERISTICS: POWER SUPPLY OF 120 VAC/1 PHASE/60 Hz AND POWER CONSUMPTION OF 2 AMPS. PROVIDE HARD WIRED CONNECTION TO POWER AIR COMPRESSOR. AIR COMPRESSOR MOTOR SHALL HAVE INTERGAL OVERLOAD PROTECTION. DV 2 120 1 1 1700 PRE-FABRICATED DRY VALVE PACKAGE SUPPLIED BY A NITROGEN GENERATOR. THE PACKAGE SHALL BE UL LISTED. DRY VALVE SERVE THE GARAGE ON LEVEL 1. PROVIDE EMERGENCY POWER FOR AIR COMPRESSORS. CONTRACTOR TO COORDINATE FINAL AIR COMPRESSOR REQUIREMENTS WITH ELECTRICAL CONTRACTOR BASED ON SYSTEM VOLUME AND ESTIMATED FILL TIME AS DETERMINED BY THEIR CALCULATIONS. COORDINATE WITH ALL TRADES TO ALLOW ADEQUATE CLEARANCES. PROVIDE NITROGEN GENERATOR TO SUPPLY DRY PIPE SYSTEMS IN LIEU OF COMPRESSED AIR. NITROGEN GENERATOR HAS THE FOLLOWING ELECTRICAL CHARACTERISTICS: POWER SUPPLY OF 120 VAC/1 PHASE/60 Hz AND POWER CONSUMPTION OF 2 AMPS. PROVIDE HARD WIRED CONNECTION TO POWER AIR COMPRESSOR. AIR COMPRESSOR MOTOR SHALL HAVE INTERGAL OVERLOAD PROTECTION. DV 3 120 1 1 1700 PRE-FABRICATED DRY VALVE PACKAGE SUPPLIED BY A NITROGEN GENERATOR. THE PACKAGE SHALL BE UL LISTED. DRY VALVE SERVE THE GARAGE ON LEVEL 1. PROVIDE EMERGENCY POWER FOR AIR COMPRESSORS. CONTRACTOR TO COORDINATE FINAL AIR COMPRESSOR REQUIREMENTS WITH ELECTRICAL CONTRACTOR BASED ON SYSTEM VOLUME AND ESTIMATED FILL TIME AS DETERMINED BY THEIR CALCULATIONS. COORDINATE WITH ALL TRADES TO ALLOW ADEQUATE CLEARANCES. PROVIDE NITROGEN GENERATOR TO SUPPLY DRY PIPE SYSTEMS IN LIEU OF COMPRESSED AIR. NITROGEN GENERATOR HAS THE FOLLOWING ELECTRICAL CHARACTERISTICS: POWER SUPPLY OF 120 VAC/1 PHASE/60 Hz AND POWER CONSUMPTION OF 2 AMPS. PROVIDE HARD WIRED CONNECTION TO POWER AIR COMPRESSOR. AIR COMPRESSOR MOTOR SHALL HAVE INTERGAL OVERLOAD PROTECTION. DV 4 120 1 1 1700 PRE-FABRICATED DRY VALVE PACKAGE SUPPLIED BY A NITROGEN GENERATOR. THE PACKAGE SHALL BE UL LISTED. DRY VALVE SERVE THE GARAGE ON LEVEL 1. PROVIDE EMERGENCY POWER FOR AIR COMPRESSORS. CONTRACTOR TO COORDINATE FINAL AIR COMPRESSOR REQUIREMENTS WITH ELECTRICAL CONTRACTOR BASED ON SYSTEM VOLUME AND ESTIMATED FILL TIME AS DETERMINED BY THEIR CALCULATIONS. COORDINATE WITH ALL TRADES TO ALLOW ADEQUATE CLEARANCES. PROVIDE NITROGEN GENERATOR TO SUPPLY DRY PIPE SYSTEMS IN LIEU OF COMPRESSED AIR. NITROGEN GENERATOR HAS THE FOLLOWING ELECTRICAL CHARACTERISTICS: POWER SUPPLY OF 120 VAC/1 PHASE/60 Hz AND POWER CONSUMPTION OF 2 AMPS. PROVIDE HARD WIRED CONNECTION TO POWER AIR COMPRESSOR. AIR COMPRESSOR MOTOR SHALL HAVE INTERGAL OVERLOAD PROTECTION. DV 5 120 1 1 1700 PRE-FABRICATED DRY VALVE PACKAGE SUPPLIED BY A NITROGEN GENERATOR. THE PACKAGE SHALL BE UL LISTED. DRY VALVE SERVE THE GARAGE ON LEVEL 1. PROVIDE EMERGENCY POWER FOR AIR COMPRESSORS. CONTRACTOR TO COORDINATE FINAL AIR COMPRESSOR REQUIREMENTS WITH ELECTRICAL CONTRACTOR BASED ON SYSTEM VOLUME AND ESTIMATED FILL TIME AS DETERMINED BY THEIR CALCULATIONS. COORDINATE WITH ALL TRADES TO ALLOW ADEQUATE CLEARANCES. PROVIDE NITROGEN GENERATOR TO SUPPLY DRY PIPE SYSTEMS IN LIEU OF COMPRESSED AIR. NITROGEN GENERATOR HAS THE FOLLOWING ELECTRICAL CHARACTERISTICS: POWER SUPPLY OF 120 VAC/1 PHASE/60 Hz AND POWER CONSUMPTION OF 2 AMPS. PROVIDE HARD WIRED CONNECTION TO POWER AIR COMPRESSOR. AIR COMPRESSOR MOTOR SHALL HAVE INTERGAL OVERLOAD PROTECTION. DV 6 120 1 1 1700 PRE-FABRICATED DRY VALVE PACKAGE SUPPLIED BY A NITROGEN GENERATOR. THE PACKAGE SHALL BE UL LISTED. DRY VALVE SERVE THE GARAGE ON LEVEL 1. PROVIDE EMERGENCY POWER FOR AIR COMPRESSORS. CONTRACTOR TO COORDINATE FINAL AIR COMPRESSOR REQUIREMENTS WITH ELECTRICAL CONTRACTOR BASED ON SYSTEM VOLUME AND ESTIMATED FILL TIME AS DETERMINED BY THEIR CALCULATIONS. COORDINATE WITH ALL TRADES TO ALLOW ADEQUATE CLEARANCES. PROVIDE NITROGEN GENERATOR TO SUPPLY DRY PIPE SYSTEMS IN LIEU OF COMPRESSED AIR. NITROGEN GENERATOR HAS THE FOLLOWING ELECTRICAL CHARACTERISTICS: POWER SUPPLY OF 120 VAC/1 PHASE/60 Hz AND POWER CONSUMPTION OF 2 AMPS. PROVIDE HARD WIRED CONNECTION TO POWER AIR COMPRESSOR. AIR COMPRESSOR MOTOR SHALL HAVE INTERGAL OVERLOAD PROTECTION. DV 7 120 1 1 1700 PRE-FABRICATED DRY VALVE PACKAGE SUPPLIED BY A NITROGEN GENERATOR. THE PACKAGE SHALL BE UL LISTED. DRY VALVE SERVE THE GARAGE ON LEVEL 1. PROVIDE EMERGENCY POWER FOR AIR COMPRESSORS. CONTRACTOR TO COORDINATE FINAL AIR COMPRESSOR REQUIREMENTS WITH ELECTRICAL CONTRACTOR BASED ON SYSTEM VOLUME AND ESTIMATED FILL TIME AS DETERMINED BY THEIR CALCULATIONS. COORDINATE WITH ALL TRADES TO ALLOW ADEQUATE CLEARANCES. PROVIDE NITROGEN GENERATOR TO SUPPLY DRY PIPE SYSTEMS IN LIEU OF COMPRESSED AIR. NITROGEN GENERATOR HAS THE FOLLOWING ELECTRICAL CHARACTERISTICS: POWER SUPPLY OF 120 VAC/1 PHASE/60 Hz AND POWER CONSUMPTION OF 2 AMPS. PROVIDE HARD WIRED CONNECTION TO POWER AIR COMPRESSOR. AIR COMPRESSOR MOTOR SHALL HAVE INTERGAL OVERLOAD PROTECTION. DV 8 120 1 PRE-FABRICATED DRY VALVE PACKAGE SUPPLIED BY A NITROGEN GENERATOR. THE PACKAGE SHALL BE UL LISTED. DRY VALVE SERVE THE GARAGE ON LEVEL 1. PROVIDE EMERGENCY POWER FOR AIR COMPRESSORS. CONTRACTOR TO COORDINATE FINAL AIR COMPRESSOR REQUIREMENTS WITH ELECTRICAL CONTRACTOR BASED ON SYSTEM VOLUME AND ESTIMATED FILL TIME AS DETERMINED BY THEIR CALCULATIONS. COORDINATE WITH ALL TRADES TO ALLOW ADEQUATE CLEARANCES. PROVIDE NITROGEN GENERATOR TO SUPPLY DRY PIPE SYSTEMS IN LIEU OF COMPRESSED AIR. NITROGEN GENERATOR HAS THE FOLLOWING ELECTRICAL CHARACTERISTICS: POWER SUPPLY OF 120 VAC/1 PHASE/60 Hz AND POWER CONSUMPTION OF 2 AMPS. PROVIDE HARD WIRED CONNECTION TO POWER AIR COMPRESSOR. AIR COMPRESSOR MOTOR SHALL HAVE INTERGAL OVERLOAD PROTECTION. DRY VALVE ASSEMBLY SCHEDULE EQUIPTME NT TAG ELECTRICAL EQUIPTMENT REMARKS TYPE # VOLT AGE TEXT PHA SE H P RPM DV 1 120 1 1 1700 PRE-FABRICATED DRY VALVE PACKAGE SUPPLIED BY A NITROGEN GENERATOR. THE PACKAGE SHALL BE UL LISTED. DRY VALVE SERVE THE GARAGE ON LEVEL 1. PROVIDE EMERGENCY POWER FOR AIR COMPRESSORS. CONTRACTOR TO COORDINATE FINAL AIR COMPRESSOR REQUIREMENTS WITH ELECTRICAL CONTRACTOR BASED ON SYSTEM VOLUME AND ESTIMATED FILL TIME AS DETERMINED BY THEIR CALCULATIONS. COORDINATE WITH ALL TRADES TO ALLOW ADEQUATE CLEARANCES. PROVIDE NITROGEN GENERATOR TO SUPPLY DRY PIPE SYSTEMS IN LIEU OF COMPRESSED AIR. NITROGEN GENERATOR HAS THE FOLLOWING ELECTRICAL CHARACTERISTICS: POWER SUPPLY OF 120 VAC/1 PHASE/60 Hz AND POWER CONSUMPTION OF 2 AMPS. PROVIDE HARD WIRED CONNECTION TO POWER AIR COMPRESSOR. AIR COMPRESSOR MOTOR SHALL HAVE INTERGAL OVERLOAD PROTECTION. DV 2 120 1 1 1700 PRE-FABRICATED DRY VALVE PACKAGE SUPPLIED BY A NITROGEN GENERATOR. THE PACKAGE SHALL BE UL LISTED. DRY VALVE SERVE THE GARAGE ON LEVEL 1. PROVIDE EMERGENCY POWER FOR AIR COMPRESSORS. CONTRACTOR TO COORDINATE FINAL AIR COMPRESSOR REQUIREMENTS WITH ELECTRICAL CONTRACTOR BASED ON SYSTEM VOLUME AND ESTIMATED FILL TIME AS DETERMINED BY THEIR CALCULATIONS. COORDINATE WITH ALL TRADES TO ALLOW ADEQUATE CLEARANCES. PROVIDE NITROGEN GENERATOR TO SUPPLY DRY PIPE SYSTEMS IN LIEU OF COMPRESSED AIR. NITROGEN GENERATOR HAS THE FOLLOWING ELECTRICAL CHARACTERISTICS: POWER SUPPLY OF 120 VAC/1 PHASE/60 Hz AND POWER CONSUMPTION OF 2 AMPS. PROVIDE HARD WIRED CONNECTION TO POWER AIR COMPRESSOR. AIR COMPRESSOR MOTOR SHALL HAVE INTERGAL OVERLOAD PROTECTION. DV 3 120 1 1 1700 SAME AS ABOVE EXCEPT SERVES LEVEL 2 DV 4 120 1 1 1700 SAME AS ABOVE EXCEPT SERVES LEVEL 2 DV 5 120 1 1 1700 SAME AS ABOVE EXCEPT SERVES LEVEL 3 DV 6 120 1 1 1700 SAME AS ABOVE EXCEPT SERVES LEVEL 3 DV 7 120 1 1 1700 SAME AS ABOVE EXCEPT SERVES LEVEL 4DV3FILL TIME AS DETERMINED BY THEIR CALCULATIONS. COORDINATE WITH ALL TRADES TO ALLOW ADEQUATE CLEARANCES. PROVIDE NITROGEN GENERATOR TO SUPPLY DRY PIPE SYSTEMS IN LIEU OF COMPRESSED AIR. NITROGEN GENERATOR HAS THE FOLLOWING ELECTRICAL CHARACTERISTICS: POWER SUPPLY OF 120 VAC/1 PHASE/60 Hz AND POWER CONSUMPTION OF 2 DV 7 120 1 1 1700 SAME AS ABOVE EXCEPT SERVES LEVEL 48 MJA BTP120105 BTP120104 ELEV#2 ELEV#1 BTP120106 UP UP 4.5% 4.5% BTP120101 BTP120109 BTP120107 BTP120102 BTP120103 UP TO LEVEL 1.5 UP TO LEVEL 2 BTP120108 BTP120110 BTP120111 BTP120112 BTP120113 STR#1 STR#2 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 2 DV 1 DV 4 DV 5 DV3 DV 6 DV 1 2 3 4 5 6 6 7 N NOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-FP-v2020.rvt2/8/2022 8:58:57 AM1/16" = 1'-0" 405 113 0 AE 0054-17 INL INL MJA I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MFP501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL FIRE PROTECTION PLAN - LEVEL 1 BRT-405-MFP500 SCALE: 1/16" = 1'-0"405-MFP501 FIRE PROTECTION PLAN - LEVEL 1 & 1.5 1 SHEET NOTES: 1.REFER TO SHEET MFN501 AND MFN502 FOR MORE INFORMATION. 2.EQUIPMENT SHOWN IS DIAGRAMMATIC AND IS NOT INTENDED TO SHOW EVERY PIECE OF EQUIPMENT NECESSARY. THE CONTRACTOR IS RESPONSIBLE FOR A COMPLETE, COMPLIANT SYSTEM. 3.ANY SIZES SHOWN ARE FOR REFERENCE ONLY. FINAL PIPE AND EQUIPMENT SIZES ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR BASED ON THEIR HYDRAULIC CALCULATIONS. 4.THE FINAL SIZE, QUANTITY, AND LOCATIONS OF DRY SPRINKLER VALVES PROVIDED IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR IN ACCORDANCE WITH THEIR CALCULATIONS. NUMBERED NOTES: 1 PIPING TO BE INSULATED AND HEAT TRACED. FOR ALL WET PIPING INSTALLED IN AREAS SUBJECT TO TEMPERATURES BELOW 40F. FIRE ALARM SHALL MONITOR LOSS OF POWER TO HEAT TRACE SYSTEM. TYPICAL. 2 4-WAY, SQUARE PATTERN FLUSH-MOUNTED FIRE DEPARTMENT CONNECTION FOR MANUAL DRY STANDPIPES. 3 PROVIDE CHECK VALVE WITH AUTO BALL DRIP FOR FDC PIPING. 4 INSTALL 6" DOUBLE CHECK BACKFLOW PREVENTER. 5 INCOMING 8" FIRE SERVICE PIPING. 6 SPRINKLER PIPING UP 7 2-WAY, SQUARE PATTERN FLUSH-MOUNTED FIRE DEPARTMENT CONNECTION FOR SPRINKLERS. ELEV#2 ELEV#1 BTP120202 BTP120201 BTP120203 UP4.2% UP4.2% STR#1 UP TO LEVEL 3 DOWN TO LEVEL 1.5 UP TO LEVEL 2.5 UP TO LEVEL 2.5 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 1 N NOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-FP-v2020.rvt2/8/2022 8:59:01 AM1/16" = 1'-0" 405 114 0 AE 0054-17 INL INL Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MFP502PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL FIRE PROTECTION PLAN - LEVEL 2 BRT-405-MFP500 SCALE: 1/16" = 1'-0"405-MFP502 FIRE PROTECTION PLAN - LEVEL 2 & 2.5 1 SHEET NOTES: 1.REFER TO SHEET MFN501 AND MFN502 FOR MORE INFORMATION. 2.EQUIPMENT SHOWN IS DIAGRAMMATIC AND IS NOT INTENDED TO SHOW EVERY PIECE OF EQUIPMENT NECESSARY. THE CONTRACTOR IS RESPONSIBLE FOR A COMPLETE, COMPLIANT SYSTEM. 3.ANY SIZES SHOWN ARE FOR REFERENCE ONLY. FINAL PIPE AND EQUIPMENT SIZES ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR BASED ON THEIR HYDRAULIC CALCULATIONS. 4.THE FINAL SIZE, QUANTITY, AND LOCATIONS OF DRY SPRINKLER VALVES PROVIDED IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR IN ACCORDANCE WITH THEIR CALCULATIONS. NUMBERED NOTES: 1 SPRINKLER PIPING UP MJA ELEV#2 ELEV#1 STR#1 STR#2 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 1 N NOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-FP-v2020.rvt2/8/2022 8:59:03 AM1/16" = 1'-0" 405 115 0 AE 0054-17 INL INL Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MFP503PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL FIRE PROTECTION FIRE PROTECTION PLAN - LEVEL 3 BRT-405-MFP500 SCALE: 1/16" = 1'-0"405-MFP503 FIRE PROTECTION LEVEL - LEVEL 3 & 3.5 1 SHEET NOTES: 1.....1.REFER TO SHEET MFN501 AND MFN502 FOR MORE INFORMATION. 2.EQUIPMENT SHOWN IS DIAGRAMMATIC AND IS NOT INTENDED TO SHOW EVERY PIECE OF EQUIPMENT NECESSARY. THE CONTRACTOR IS RESPONSIBLE FOR A COMPLETE, COMPLIANT SYSTEM. 3.ANY SIZES SHOWN ARE FOR REFERENCE ONLY. FINAL PIPE AND EQUIPMENT SIZES ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR BASED ON THEIR HYDRAULIC CALCULATIONS. 4.THE FINAL SIZE, QUANTITY, AND LOCATIONS OF DRY SPRINKLER VALVES PROVIDED IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR IN ACCORDANCE WITH THEIR CALCULATIONS. NUMBERED NOTES: 1 RISER UP MJA ELEV#2 ELEV#1 BTP120402 BTP120401 BTP120403 STR#2 STR#1 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 1 7 DV 8 DV N NOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-FP-v2020.rvt2/8/2022 8:59:05 AM1/16" = 1'-0" 405 116 0 AE 0054-17 INL INL Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MFP504PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL FIRE PROTECTION PLAN - LEVEL 4 BRT-405-MFP500 SCALE: 1/16" = 1'-0"405-MFP504 FIRE PROTECTION PLAN - LEVEL 4 & 4.5 1 SHEET NOTES: 1.....1.REFER TO SHEET MFN501 AND MFN502 FOR MORE INFORMATION. 2.EQUIPMENT SHOWN IS DIAGRAMMATIC AND IS NOT INTENDED TO SHOW EVERY PIECE OF EQUIPMENT NECESSARY. THE CONTRACTOR IS RESPONSIBLE FOR A COMPLETE, COMPLIANT SYSTEM. 3.ANY SIZES SHOWN ARE FOR REFERENCE ONLY. FINAL PIPE AND EQUIPMENT SIZES ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR BASED ON THEIR HYDRAULIC CALCULATIONS. 4.THE FINAL SIZE, QUANTITY, AND LOCATIONS OF DRY SPRINKLER VALVES PROVIDED IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR IN ACCORDANCE WITH THEIR CALCULATIONS. NUMBERED NOTES: 1 LEVEL 4 DRY PIPE VALVES NEED TO BE LOCATED IN A HEATED ROOM (ABOVE 40 DEGREES F). HEAT TRACED PIPE OR A CONDITIONED CHASE NEEDS TO BE PROVIDED FOR THE DRY PIPE VALVES ON LEVEL 4. IF HEAT TRACED PIPE IS PROVIDED IT HAS TO MONITORED FOR POWER LOSS BY THE FIRE ALARM SYSTEM. IF POSSIBLE LOCATE LEVEL 4 DRY PIPE VALVES IN BPT120110. MJA ELEV#2 ELEV#1 UP4.2% UP4.2% STR#1 STR#2 DOWN TO LEVEL 4.5 UP TO LEVEL 5.5 UP TO LEVEL 5.5 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 N NOT FOR CONSTRUCTION DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-FP-v2020.rvt2/8/2022 8:59:07 AM1/16" = 1'-0" 405 117 0 AE 0054-17 INL INL MJA I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MFP505PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL FIRE PROTECTION PLAN - LEVEL 5 BRT-405-MFP500 SCALE: 1/16" = 1'-0"405-MFP505 FIRE PROTECTION PLAN - LEVEL 5 & 5.5 1 SHEET NOTES: 1.....1.REFER TO SHEET MFN501 AND MFN502 FOR MORE INFORMATION. 2.EQUIPMENT SHOWN IS DIAGRAMMATIC AND IS NOT INTENDED TO SHOW EVERY PIECE OF EQUIPMENT NECESSARY. THE CONTRACTOR IS RESPONSIBLE FOR A COMPLETE, COMPLIANT SYSTEM. 3.ANY SIZES SHOWN ARE FOR REFERENCE ONLY. FINAL PIPE AND EQUIPMENT SIZES ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR BASED ON THEIR HYDRAULIC CALCULATIONS. 4.THE FINAL SIZE, QUANTITY, AND LOCATIONS OF DRY SPRINKLER VALVES PROVIDED IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR IN ACCORDANCE WITH THEIR CALCULATIONS. NUMBERED NOTES: 2. 1. WITH LOCAL FIRE DEPARTMENT. THREADS ON FIRE DEPT. CONNECTION SPRINKLER CONTRACTOR TO COORDINATE WITH LOCAL FIRE DEPARTMENT. HEIGHT & LOCATION OF FIRE DEPT. CONNECTION SPRINKLER CONTRACTOR TO COORDINATE NOTES GRADE 18"-48" (4) x 2 1/2" CONNECTIONS STANDPIPE FIRE DEPT CONN TT TO FIRE SUPPRESSION SYSTEM OSY VALVE W/TAMPER SWITCH -TYPICAL SHALL MEET ASSE 1048 DOUBLE CHECK VALVE SIZE PER NFPA 13 FROM WATER SUPPLY SYSTEM INSPECTORS TEST/DRAIN STATION -SPILL TO FLOOR OR FLOOR DRAIN WITH AIR GAP DISCHARGE. STANDPIPE 175LB. WWP NOTES: 1.ALL FHV'S TO BE LOCATED A MAXIMUM OF 5'-0" A.F.F. 2.ALL THREADS AS APPROVED BY LOCAL FIRE MARSHALL'S OFFICE. 2-1/2" ANGLE VALVE 2-1/2" X 1-1/2" REDUCER CAP AND CHAIN LUGS FOR SPANNER DSPDSP LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5 LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5 FIRE DEPARTMENT CONNECTION 2½"FDV 2½"FDV 2½"FDV 2½"FDV 2½" FDV FIRE DEPARTMENT CONNECTION DSP2½"FDV 2½"FDV 2½"FDV 2½"FDV 2½" FDV DSPDSPDOUBLE CHECK DETECTOR BACKFLOW PREVENTER ASSEMBLY T T 8" WATER SERVICE F DSP DSP2½"FDV 2½"FDV 2½"FDV 2½"FDV 2½" FDV DSPDSP DSP2½"FDV 2½"FDV 2½"FDV 2½"FDV 2½" FDV DSPDSP DSP2½"FDV 2½"FDV 2½"FDV 2½"FDV 2½" FDV DSPDSP DSP2½"FDV 2½"FDV 2½"FDV 2½"FDV 2½" FDV DSPDRY VALVE F T CONTROL VALVE WITH TAMPER SWITCH CHECK VALVE FLOW SWITCH 2-1/2" FIRE HOSE VALVE 2-1/2" FIRE HOSE VALVE IN CABINET LEGEND: RISER IS DIAGRAMMATIC ONLY AND NOT INTENDED TO SHOW ELEVATIONS OF EQUIPMENT ABOVE FLOOR LEVELS ACCURATELY. REFER TO FLOOR PLANS FOR EXACT EQUIPMENT LOCATIONS. NOTES: T DP T T T T T T T DP DP DP DP DP DP DP 2. 1. WITH LOCAL FIRE DEPARTMENT. THREADS ON FIRE DEPT. CONNECTION SPRINKLER CONTRACTOR TO COORDINATE WITH LOCAL FIRE DEPARTMENT. HEIGHT & LOCATION OF FIRE DEPT. CONNECTION SPRINKLER CONTRACTOR TO COORDINATE NOTES GRADE 18"-48" (3) x 2 1/2" CONNECTIONS AUTO SPKR FIRE DEPT CONN N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-FP-v2020.rvt2/8/2022 8:58:54 AMNTS 405 118 0 AE 0054-17 INL INL MJA I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-MFD501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL MECHANICAL FIRE PROTECTION DETAILS BRT-405-MFD500 NTS3STANDPIPE FIRE DEPARTMENT CONNECTION DETAIL NTS2BACKFLOW PREVENTER ASSEMBLY DETAIL NTS1FIRE HOSE VALVE DETAIL 1 NTS5FIRE PROTECTION RISER DIAGRAM MANUAL DRY STANDPIPENTS4SPRINKLER FIRE DEPARTMENT CONNECTION DETAIL TV GFR S B P B J J M CTB T F VFD VFD EPO G G $ $ $ $ $ LC $ $ $ PC P L 2S 2D 4D 4S DZC $ $ OS OS TVTV WAP XX,XXXASPD B B B B M M M GFP OS OS VS VS GROUND FAULT RELAY ABBREVIATIONS CENTER LINE AFF ABOVE FINISHED FLOOR AIC AMPERES INTERRUPTING CAPACITY AF/AS AMPERE RATING OF FUSE/SWITCH AT/AF AMPERE RATING OF CIRCUIT, BREAKER TRIP/FRAME ATS AUTOMATIC TRANSFER SWITCH BMS BUILDING MANAGEMENT SYSTEM CKT CIRCUIT DPDT DOUBLE POLE DOUBLE THROW DPST DOUBLE POLE SINGLE THROW (E)EXISTING TO REMAIN EC EMPTY CONDUIT ECC ENGINEER'S CONTROL CENTER ELEV ELEVATOR EMT ELECTRICAL METALLIC TUBING FCC FIRE CONTROL CENTER GFI GROUND FAULT CIRCUIT INTERRUPTOR GND GROUND IDF INTERMEDIATE DISTRIBUTION FRAME ROOM IN INCH MCP MOTOR CIRCUIT PROTECTOR MDF MAIN DISTRIBUTION FRAME ROOM MIC MINERAL INSULATED CABLE (N)NEW NC NORMALLY CLOSED NO NORMALLY OPEN NTS NOT TO SCALE PVC POLYVINYL CHLORIDE CONDUIT (R) EXISTING TO BE RELOCATED RAC RIGID ALUMINUM CONDUIT RSC RIGID STEEL CONDUIT SCC SECURITY CONTROL CENTER SLD SINGLE LINE DIAGRAM SPST SINGLE POLE SINGLE THROW TEL TELECOM TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION TYP TYPICAL UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY WP WEATHERPROOF WT WATERTIGHT (X) EXISTING TO BE REMOVED XP EXPLOSION PROOF POWER LEGEND ATS, CPC, DPH, DPL, DSH, DSL, MCC OR MS: SIZE APPROXIMATELY AS SHOWN. DOUBLE LINE INDICATES FRONT. SURFACE MOUNTED PANELBOARD:277/480V SIZE APPROXIMATELY AS SHOWN RECESSED MOUNTED PANELBOARD:277/480V SIZE APPROXIMATELY AS SHOWN SURFACE MOUNTED PANELBOARD:120/208V SIZE APPROXIMATELY AS SHOWN RECESSED MOUNTED PANELBOARD:120/208V SIZE APPROXIMATELY AS SHOWN TELECOM BACKBOARD: LENGTH APPROXIMATELY AS SHOWN BUSWAY RISER WITH PLUG IN UNIT, FUSE BUSWAY RISER WITH PLUG IN UNIT, BREAKER BUSWAY HORIZONTAL CABLE TAP BOX STEP DOWN TRANSFORMER GENERATOR GENERATOR IN WP ENCLOSURE HEAVY DUTY DISCONNECT SWITCH HEAVY DUTY DISCONNECT SWITCH WITH FUSE MOTOR STARTER COMBINATION MOTOR STARTER/DISCONNECT SWITCH VFD WITH DISCONNECT, NOT PROVIDED UNDER ELECTRICAL SCOPE VFD WITHOUT DISCONNECT, NOT PROVIDED UNDER ELECTRICAL SCOPE EMERGENCY POWER OFF BUTTON MOTORIZED DOOR CONTROLLER (FURNISHED WITH DOOR) MOTORIZED SHADE CONTROLLER (FURNISHED WITH SHADES) PROJECTION SCREEN CONTROLLER (FURNISHED WITH SCREEN) SPEED CONTROLLER (FURNISHED WITH EQUIPMENT) THERMAL OVERLOAD/DISCONNECT SWITCH MOTOR CONNECTION JUNCTION BOX, CEILING MOUNTED JUNCTION BOX, WALL MOUNTED PULL BOX SPLICE BOX FLOOR GROUND BAR CIRCUIT BREAKER SWITCH AND FUSE DRAWOUT TYPE CIRCUIT BREAKER DRAWOUT TYPE SWITCH AND FUSE CIRCUIT BREAKER IN ENCLOSURE CURRENT TRANSFORMER TRANSFORMER RACEWAY LEGEND CONDUIT CONCEALED ABOVE CEILING OR WITHIN WALL CONDUIT BELOW GRADE OR EMBEDDED WITHIN SLAB CONDUIT UP CONDUIT DOWN CONDUIT STUBBED OUT WITH BUSHING NOTE: PROVIDE PULLSTRING IN EACH EMPTY RACEWAY CONDUIT STUBBED OUT AND CAPPED NOTE: PROVIDE PULLSTRING IN EACH EMPTY RACEWAY AUDIO/VISUAL SYSTEM RACEWAY CABLE TRAY GROUNDING SYSTEM RACEWAY FIRE ALARM SYSTEM RACEWAY SECURITY SYSTEM RACEWAY NOTE: PROVIDE PULLSTRING IN EACH EMPTY RACEWAY TELECOM SYSTEM RACEWAY NOTE: PROVIDE PULLSTRING IN EACH EMPTY RACEWAY TELEVISION SYSTEM RACEWAY NOTE: PROVIDE PULLSTRING IN EACH EMPTY RACEWAY CONDUIT HOMERUN NOTE: MAXIMUM OF THREE BRANCH CIRCUITS FOR EACH HOMERUN, UON DUPLEX RECEPTACLE OUTLET: 125V ONE HALF SWITCHED PUSH BUTTON POWER TYPE PLUGSTRIP OR SURFACE RACEWAY, LENGTH APPROXIMATELY AS SHOWN TELECOM TYPE PLUGSTRIP OR SURFACE RACEWAY, LENGTH APPROXIMATELY AS SHOWN TELEVISION COAXIAL OUTLET WIRING DEVICE LEGEND COMBINATION DUPLEX RECEPTACLE/TELECOM OUTLET: 125V COMBINATION DOUBLE DUPLEX RECEPTACLE/ TELECOM OUTLET: 125V TELECOM OUTLET POWER CONNECTION TO ELECTRIFIED FURNITURE SYSTEM TELECOM CONNECTION TO ELECTRIFIED FURNITURE SYSTEM DUPLEX RECEPTACLE OUTLET: 125V DEDICATED DUPLEX RECEPTACLE OUTLET: 125V WIRING DEVICE SUBSCRIPT LEGEND AC = ABOVE COUNTER GFI = GROUND FAULT CIRCUIT INTERRUPTER IG = ISOLATED GROUND WP = WEATHERPROOF a = LOWER CASE LETTER INDICATES SWITCH CONTROL 6 = NUMBER INDICATES CIRCUIT NUMBER IG = ISOLATED GROUND (ONE OF DOUBLE DUPLEX) ELECTRICAL LEGEND AND ABBREVIATIONS EQUIPMENT TAG GROUNDING CONDUCTOR PHASE CONDUCTOR(S) ISOLATED GROUNDING CONDUCTOR NEUTRAL CONDUCTOR A AMPERES AL ALUMINUM C CONDUIT (GENERIC TERM FOR RACEWAY - PROVIDE AS SPECIFIED) CATV CABLE TELEVISION CB CIRCUIT BREAKER CU COPPER DWG DRAWING EWC ELECTRIC WATER COOLER FA FIRE ALARM FP FIRE PROTECTION SYSTEM INSTALLER GC GENERAL CONTRACTOR JB JUNCTION BOX HP HORSEPOWER HVAC HEATING, VENTILATING AND AIR CONDITIONING INSTALLER KCMIL THOUSAND CIRCULAR MILS KVA KILO-VOLT AMPERE KW KILO-WATT LTG LIGHTING MCB MAIN CIRCUIT BREAKER MDP MAIN DISTRIBUTION PANEL MLO MAIN LUGS ONLY MTD MOUNTED MTG MOUNTING MTS MANUAL TRANSFER SWITCH NIC NOT IN CONTACT P POLE PL PLUMBING SYSTEM INSTALLER PWR POWER RGS RIGID GALVANIZED STEEL SN SOLID NEUTRAL PH PHASE PB PULL BOX SF-1 TB TELECOM BACKBOARD CEILING FLOOR WALL N/A N/A N/A N/A SPECIAL PURPOSE RECEPTACLE OUTLET: RATING AS INDICATED N/AN/A BUZZER BELL DOUBLE DUPLEX RECEPTACLE OUTLET: 125V ONE HALF SWITCHED N/A N/A ONE-LINE DIAGRAM LEGEND AUTOMATIC TRANSFER SWITCH PANEL - REFER TO EQUIPMENT NAMING LEGEND ON THIS SHEET BUS RACEWAY DISCONNECT SWITCH FUSED DISCONNECT SWITCH MOTOR LIGHTING DEVICE LEGEND LIGHTING CONTROL SWITCH. LOW VOLTAGE, UON ILLUMINATED HANDLE SWITCH KEY SWITCH TIMER SWITCH PHOTOCELL OCCUPANCY SENSOR; WALL MOUNTED OCCUPANCY SENSOR; CEILING MOUNTED LIGHTING LEGEND LIGHTING FIXTURE; CEILING MOUNTED LIGHTING FIXTURE; WALL MOUNTED LIGHTING FIXTURE, SIZE APPROXIMATELY AS SHOWN; CEILING MOUNTED LIGHTING FIXTURE, SIZE APPROXIMATELY AS SHOWN; WALL MOUNTED LIGHTING FIXTURE CONNECTED TO EMERGENCY POWER SYSTEM LIGHTING FIXTURE, CONTINUOUS ROW; CEILING MOUNTED LIGHTING FIXTURE, WALL WASHER; CEILING MOUNTED LIGHTING FIXTURE(S); POLE MOUNTED LIGHTING FIXTURE SUBSCRIPTS: NUMBER INDICATES CIRCUIT, LOWERCASE LETTER INDICATES SWITCH CONTROL UPPERCASE LETTER INDICATES FIXTURE TYPE LIGHTING TRACK WITH FIXTURES, LENGTH APPROXIMATELY AS SHOWN ARROWS AS SHOWN, ILLUMINATED FACE AS INDICATED BY SHADING, CONNECT TO EMERGENCY POWER SYSTEM EXIT SIGN; WALL MOUNTED EXIT SIGN; CEILING MOUNTED EXIT SIGN; PENDENT MOUNTED EXIT SIGN, LOW LEVEL; RECESSED IN WALL EXIT SIGNS 2 a A 2-BUTTON LOW-VOLTAGE WALL SWITCH 2-BUTTON LOW-VOLTAGE WALL-MOUNTED DIMMING SCENE SELECTOR WITH RAISE/LOWER DIMMING ZONE CONTROLLER, RECESSED IN WALL 4-BUTTON LOW-VOLTAGE WALL SWITCH 4-BUTTON LOW-VOLTAGE WALL-MOUNTED DIMMING SCENE SELECTOR WITH RAISE/LOWER OCCUPANCY SENSOR SWITCH +XX" = MOUNTING HEIGHT ABOVE FINISHED FLOOR WIRELESS ACCESS POINTN/AN/A COMBINATION VOICE & TELECOM OUTLET SURGE PROTECTION DEVICE GROUND SHORT CIRCUIT CURRENT AVAILABLE UTILITY METERING BASE COMBINATION MOTOR STARTER/DISCONNECT SWITCH GFP GROUND FAULT PROTECTOR FOR EQUIPMENT CUSTOMER ENERGY METERING DISTRIBUTION SWITCHBOARD LSIG LONG TIME, SHORT TIME, INSTANTANEOUS, GROUND GROUND FAULT PROTECTION OCCUPANCY SENSOR; WALL MOUNTED OCCUPANCY SENSOR; CEILING MOUNTED VACANCY SENSOR; WALL MOUNTED VACANCY SENSOR; CEILING MOUNTED DOUBLE DUPLEX RECEPTACLE OUTLET: 125V AC GFI IG WP a 6 IG MD MS PS SC T AV CT G FA S T TV - - - H K T OS +XX" A/V AUDIO/VISUAL EV ELECTRIC VEHICLE IG ISOLATED GROUND U/G UNDERGROUND SPST SINGLE POLE SINGLE THROW DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERMJ 02/11/22 02/11/22BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-E-v2020.rvt2/3/2022 12:45:37 PM12" = 1'-0" 405 119 BRT-405-003-E-v2020 AE 0054-17 Designer Author MJ MJ I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-EPN501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL ELECTRICAL ELECTRICAL LEGENDS AND ABBREVIATIONS SHEET NOTES: 1.THIS IS A STANDARD LEGEND SHEET. NOT ALL SYMBOLS USED IN THIS PROJECT. CHARGER CHARGER CHARGER CHARGER CHARGER CHARGER IT CHARGER CHARGER TRANSFORMER CHARGER SWITCHGEAR CHARGER CHARGER CHARGER 12345678910111213A D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 BUS BAY BUS BAY C B PROPOSED U/G ELECTRICAL SERVICE TO GARAGE (REFER SLD) PROPOSED LOCATION OF GARAGE UTILITY TRANSFORMER 10'x10' PAD, CABLE VAULT BELOW (3' CLEAR THREE SIDES, 10' CLEAR ONE SIDE) 1 1 SHEET NOTES: 1. BUS CHARGING CRITERIA AND EQUIPMENT TO BE ADVISED.BUS CHARGING WILL BE SERVED BY A SEPARATE UTILITY SERVICE, AND SERVICE EQUIPMENT. LOCATIONS AND RATINGS OF EQUIPMENT TO BE DETERMINED WHEN CRITERIA IS AVAILABLE. 2. CO-ORDINATE ALL UNDER GROUND ELECTRICAL WORK WITH OTHER TRADES. 1. 12 IN X 12 IN X 12 IN HANDHOLE USED AS “MEET ME POINT”. ONE FOR KING COUNTY METRO TWELVE (12) 20A 120V CIRCUITS. ONE FOR SOUND TRANSIT, TWELVE (12) 20A 120V CIRCUITS. NUMBERED NOTES# DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERMJ 02/11/22 02/11/22BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-E-v2020.rvt2/3/2022 12:45:52 PM1" = 30'-0" 405 120 BRT-405-003-E-v2020 AE 0054-17 Designer Author MJ MJ I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-ESP501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL ELECTRICAL ELECTRICAL GARAGE SITE PLAN SCALE: 1" = 30'-0"405-ESP501 ELECTRICAL POWER -SITE PLAN 1 BTP120105 BTP120104 ELEV#2 ELEV#1 BTP120106 UP UP 4.5% 4.5% BTP120101 BTP120109 BTP120107 BTP120102 BTP120103 UP TO LEVEL 1.5 UP TO LEVEL 2 BTP120108 BTP120110 BTP120111 BTP120112 BTP120113 STR#1 STR#2 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 405-EEP501 1 TICKET MACHINE #1 TICKET MACHINE #2 N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERMJ 02/11/22 02/11/22BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-E-v2020.rvt2/3/2022 12:45:38 PM1/16" = 1'-0" 405 121 BRT-405-003-E-v2020 AE 0054-17 Designer Author MJ MJ I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-EPP501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL ELECTRICAL ELECTRICAL POWER PLAN - LEVEL 1 SCALE: 1/16" = 1'-0"405-EPP501 ELECTRICAL POWER PLAN - LEVEL 1 & 1.5 1 SHEET NOTES: 1. REFER TO ARCHITECT'S DRAWINGS FOR DESIGNATED EV STALLS INSTALLED, STALLS PROVIDED WITH CHARGING INFRASTRUCTURE, AND FUTURE EV STALLS. 2. LIGHTING LAYOUT SHOWN AT 60%. ALL LIGHTING TO BE LED. ALL LIGHTING AND LIGHTING CONTROLS TO COMPLY WITH WASHINGTON STATE ENERGY CODE. 3. ELECTRICAL OUTLETS AND EQUIPMENT SHOWN AT 60%. ELEV#2 ELEV#1 BTP120202 BTP120201 BTP120203 UP4.2% UP4.2% STR#2 STR#1 UP TO LEVEL 3 DOWN TO LEVEL 1.5 UP TO LEVEL 2.5 UP TO LEVEL 2.5 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 405-EEP501 2 1 N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERMJ 02/11/22 02/11/22BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-E-v2020.rvt2/3/2022 12:45:40 PM1/16" = 1'-0" 405 122 BRT-405-003-E-v2020 AE 0054-17 Designer Author MJ MJ I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-EPP502PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL ELECTRICAL ELECTRICAL POWER PLAN - LEVEL 2 SCALE: 1/16" = 1'-0"405-EPP502 ELECTRICAL POWER PLAN - LEVEL 2 & 2.5 1 NUMBERED NOTES: 1 LOCATION OF FUTURE RISER TO SOLAR ZONE. SHEET NOTES: 1. LIGHTING LAYOUT SHOWN AT 60%. ALL LIGHTING TO BE LED. ALL LIGHTING AND LIGHTING CONTROLS TO COMPLY WITH WASHINGTON STATE ENERGY CODE. 2. ELECTRICAL OUTLETS AND EQUIPMENT SHOWN AT 60%. ELEV#2 ELEV#1 UP4.2% UP4.2% STR#1 STR#2 UP TO LEVEL 4 DOWN TO LEVEL 2.5 UP TO LEVEL 3.5 UP TO LEVEL 3.5 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 1 N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERMJ 02/11/22 02/11/22BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-E-v2020.rvt2/3/2022 12:45:42 PM1/16" = 1'-0" 405 123 BRT-405-003-E-v2020 AE 0054-17 Designer Author MJ MJ I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-EPP503PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL ELECTRICAL ELECTRICAL POWER PLAN - LEVEL 3 SCALE: 1/16" = 1'-0"405-EPP503 ELECTRICAL POWER PLAN - LEVEL 3 & 3.5 1 NUMBERED NOTES: 1 LOCATION OF FUTURE RISER TO SOLAR ZONE. SHEET NOTES: 1. LIGHTING LAYOUT SHOWN AT 60%. ALL LIGHTING TO BE LED. ALL LIGHTING AND LIGHTING CONTROLS TO COMPLY WITH WASHINGTON STATE ENERGY CODE. 2. ELECTRICAL OUTLETS AND EQUIPMENT SHOWN AT 60%. ELEV#2 ELEV#1 BTP120402 BTP120401 BTP120403 UP4.2% UP4.2% STR#2 STR#1 UP TO LEVEL 5 DOWN TO LEVEL 3.5 UP TO LEVEL 4.5 UP TO LEVEL 4.5 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 405-EEP501 3 1 N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERMJ 02/11/22 02/11/22BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-E-v2020.rvt2/3/2022 12:45:44 PM1/16" = 1'-0" 405 124 BRT-405-003-E-v2020 AE 0054-17 Designer Author MJ MJ I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-EPP504PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL ELECTRICAL ELECTRICAL POWER PLAN - LEVEL 4 SCALE: 1/16" = 1'-0"405-EPP504 ELECTRICAL POWER PLAN - LEVEL 4 & 4.5 1 NUMBERED NOTES: 1 LOCATION OF FUTURE RISER TO SOLAR ZONE. SHEET NOTES: 1. LIGHTING LAYOUT SHOWN AT 60%. ALL LIGHTING TO BE LED. ALL LIGHTING AND LIGHTING CONTROLS TO COMPLY WITH WASHINGTON STATE ENERGY CODE. 2. ELECTRICAL OUTLETS AND EQUIPMENT SHOWN AT 60%. ELEV#2 ELEV#1 UP4.2% UP4.2% STR#1 STR#2 DOWN TO LEVEL 4.5 UP TO LEVEL 5.5 UP TO LEVEL 5.5 A C D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 1 N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERMJ 02/11/22 02/11/22BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-E-v2020.rvt2/3/2022 12:45:46 PM1/16" = 1'-0" 405 125 BRT-405-003-E-v2020 AE 0054-17 Designer Author MJ MJ I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-EPP505PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL ELECTRICAL ELECTRICAL POWER PLAN - LEVEL 5 SCALE: 1/16" = 1'-0"405-EPP505 ELECTRICAL POWER PLAN - LEVEL 5 & 5.5 1 NUMBERED NOTES: 1 LOCATION OF FUTURE RISER TO SOLAR ZONE. SHEET NOTES: 1. LIGHTING LAYOUT SHOWN AT 60%. ALL LIGHTING TO BE LED. ALL LIGHTING AND LIGHTING CONTROLS TO COMPLY WITH WASHINGTON STATE ENERGY CODE. 2. ELECTRICAL OUTLETS AND EQUIPMENT SHOWN AT 60%. 3. ALLOCATE 40% OF UNOCCUPIED ROOF SPACE PER C411 OF THE WASHINGTON STATE ENERGY CODE FOR SOLAR ZONE. ATSDIST MAIN CB METERDIST ATS DIST MAIN CB DIST DIST METERATSATS ATS BTP120111 BTP120112 BTP120113 C 11 12 13 1 2 3 4 5 6 7 8 PNL PNL PNL PNL PNL PNL LP EV CHARGING SERVICE GARAGE SERVICE GARAGE BRANCH CIRCUITS KING COUTY METRO PANELS NEC 700 NEC 701 EV CHARGING PANELS PLUS SPACE FOR FUTURE FUEL FILL 300 kVA GENSET WITH BELLY TANK (13'x6' PAD)2X CLEARANCE2X CLEARANCEGENERATOR DISTRIBUTION UPS LIGHTING INVERTER COM/IT UPS PNL D 12 PNL LP PNL PNL D 12 PNL LP PNL PNL N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERMJ02/11/22 02/11/22BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-E-v2020.rvt2/3/2022 12:45:37 PM1/4" = 1'-0" 405 126 BRT-405-003-E-v2020 AE 0054-17 Designer Author MJ MJ I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-EEP501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL ELECTRICAL ELECTRICAL ENLARGED PLANS SCALE: 1/4" = 1'-0"405-EEP501 DETAIL 1 - LEVEL 1 MAIN ELECTRICAL & GENERATOR 1 SCALE: 1/4" = 1'-0"405-EEP501 DETAIL 2 - LEVEL 2 ELECTRICAL 2 SCALE: 1/4" = 1'-0"405-EEP501 DETAIL 3 - LEVEL 4 ELECTRICAL 3 PAD MOUNT PSE UTILITY TRANSFORMER(1.0MVA 52kA) (120/208V) 400A PNL 400A PNL 400A PNL 400A PNL M 1200A 1000A EV CHARGING INFRASTRUCTURE (SHEET NOTE 1) 1200A 120/208V M 1000A 120/208V 200A 120/208V ELEV - 2 M 100A PNL 1000A 120/208V G 100A PNL 100A PNL 100A PNL 200A PNL 200A PNL 200A PNL LP LP LP 400A PNL 400A PNL 400A PNL 400A PNL UTILITY SERVICE 200A PNL 200A PNL KING COUNTY METRO PANELS FOR EQUIPMENT ON BUS RAMP GENERAL GARAGE LOADS LIGHTING CONTROL PANELS NEC 700 LOADS ELEVATOR & NEC 701 LOADS 200A ATS 1000A ATS 100A ATS 100A ATS 200A PNL 200A PNL ELEV - 1 M J 300KVA DEISEL GENERATOR 120/208V L2 ELECTRICAL ROOM L4 ELECTRICAL ROOM COMS/IT UPS 25KW FOR 10 MIN 100A PNL 100A PNL 100A PNL COMS/IT LOADS LIGHTING INVERTER 10KW FOR 10 MIN FIRE SPRINKLER DRY SYSTEM COMPRESSORS AND ANCILLARY EQUIPMENT POWER PER NFPA 13 - 8.2.6.3.1 AND 8.2.6.3.2 (PROTECT MOTORS PER NFPA 70 -430) 305KW plus 20% spare 1016A at 120/208V 3P supply 1200A SB and service Qty Diversity KW Qty Diversity KW # 0-3 3 1 18 # 0-3 3 1 18 # 4-20 17 0.75 76.5 # 4-20 17 0.75 76.5 # 21-30 10 0.5 30 # 21-30 10 0.5 30 #31- 45 0.25 67.5 #31- 120 0.25 180 Total 75 Total 192 Total 150 Total 304.5 EV Charging Infrastructure for 75 Chargers Capacity for 150 Chargers Level 2 Chargers at 208V 1P, 6 KW Initial 75 Chargers Capacity for 150 Total Chargers NEC 700 ATS Emergency Lighting 10 NEC 701 ATS Elevator #1 30 Plus 20% Spare 284.4 Amps at 120/208V 3P 790 Service Size Selected 1000 General Service for Parking Garage Load Description KW FP ATS Compressors 6 FP ATS Ancillary Equipment 1 NEC 701 ATS Elevator #2 30 NEC 701 ATS Ancillary Equipment 2 Garage SB KC Metro Platform Allowance 5 Garage SB Storage Equipment Estimate 2 Garage SB Generator Equipment Estimate 2 Garage SB Site Lighting and Equipment 2 TOTAL KW 237 Garage SB Platform Allowance 5 Garage SB Lighting (0.14w/sf per WSEC) 50 Garage SB Mechanical Systems 50 Garage SB Plumbing Systems 15 Garage SB IT / Comms Equipment Estimate 15 Garage SB Security Equipment Estimate 4 Garage SB Mens Equipment Estimate 4 Garage SB Womans Equipment Estimate 4 DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERMJ 02/11/22 02/11/22BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-E-v2020.rvt2/3/2022 12:45:46 PM12" = 1'-0" 405 127 BRT-405-003-E-v2020 AE 0054-17 Designer Author MJ MJ I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-EPS501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL ELECTRICAL ELECTRICAL ONE LINE SCALE: NTS 405-EPS501 ONE-LINE DIAGRAM 1 SHEET NOTES: 1. EV CHARGING QUANTITIES PROVIDED PER WAC 51-50-0427 INFRASTRUCTURE PROVIDED FOR 75 LEVEL 2, 6kW CHARGERS CAPACITY PROVIDED FOR 150 LEVEL 2, 6kW CHARGERS. DIVERSITY ON CHARGERS CALCULATED PER CITY OF SEATTLE CALCULATION. MANAGEMENT SYSTEM REGULATES CHARGING TO LIMITS OF DIVERSITY CALCULATION ABOVE PER WAC 51-50-0427. 2. GROUNDING AND BONDING IN ACCORDANCE WITH NEC 250 FOR EQUIPMENT AND SEPARATELY DERIVED SYSTEMS. NUMBERED NOTES: 1 2 3 1 1. FUTURE RISER FOR SOLAR READINESS 2. (12) 20A 120V CIRCUITS TO HANDHOLD IN BUS PLATFORM FOR USE OF KING COUNTY METRO. 3. (12) 20A 120V CIRCUITS TO HANDHOLD IN BUS PLATFORM FOR USE OF SOUND TRANSIT. 4. ELEVATOR EQUIPMENT IN ELEVATOR MACHINE ROOM -LAYOUT PER ELIVATOR REQUIREMENTS. 5. FIRE SUPRESSION ATS AND PANEL IN FIRE SPRINKLER ROOM. LAYOUT PER SPRINKLER REQUIREMENTS. 4 5 DC CR CR CR PB DA IC DR A AMPERE ABF AIR BLOWN FIBER AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION ANSI AMERICAN NATIONAL STANDARDS INSTITUTE AP (WIRELESS) ACCESS POINT AV AUDIOVISUAL AWG AMERICAN WIRE GAUGE BICSI BUILDING INDUSTRIES CONSULTING SERVICE INT. BMCS BUILDING MANAGEMENT CONTROL SYSTEM BTU BRITISH THERMAL UNIT C CONDUIT CAT X, UTP CATEGORY X, UNSHIELDED TWIST PAIR CATV COMMUNITY ANTENNA TV CCTV CLOSED CIRCUIT TELEVISION (ANALOG) CKT CIRCUIT CODEC CODER/DECODER (COMPRESSION/DECOMPRESSION) CP CONSOLIDATION POINT CPE CUSTOMER PREMISES EQUIPMENT CPU CENTRAP PROCESSING UNIT CR CARD READER CWDM COARSE WAVELENGTH DIVISION MULTIPLEXING COAX COAXIAL CABLE DC DOOR CONTACT DEMARC DEMARCATION POINT (TELECOMMUNICATIONS) DSL DIGITAL SUBSCRIBER LINE DWG DRAWING EMG EMERGENCY EMC ELECTROMAGNETIC COMPATIBILITY EMI ELECTROMAGNETIC INTERFERENCE EMT ELECTRICAL METALLIC TUBING ENC ELECTRICAL NONMETALLIC CONDUIT ENT ELECTRICAL NONMETALLIC TUBING FA FIRE ALARM F/UTP FOILED UNSHIELDED TWISTED PAIR FO FIBER OPTIC GHZ GIGAHERTZ (FREQUENCY) GND GROUND HH HANDHOLD (OSP CABLE ACCESS) IDC INSULATION DISPLACEMENT CONTACT (CONNECTION) IDF INTERMEDIATE DISTRIBUTION FACILITY (TELECOM) IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS IG INSULATED GROUND IMC INTERMEDIATE METAL CONDUIT JB JUNCTION BOX KVA KILOVOLT-AMPERE KW KILOWATT LAN LOCAL AREA NETWORK MAN METROPOLITAN AREA NETWORK MATV METROPOLITAN AREA TELEVISION MDF MAIN DISTRIBUTION FACILITY (TELECOM) MEP MECHANICAL, ELECTRICAL, PLUMBING MGMT MANAGEMENT MH MAINTENANCE HOLE (OSP CABLE ACCESS) MHZ MEGAHERTZ (FREQUENCY) MM MULTIMODE mm MILIMETERS MuTOA MULTI-USER TELECOMMUNICATIONS OUTLET ASSEMBLY NEC NATIONAL ELECTRIC CODE (NFPA) NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOC. NIC NOT IN CONTRACT NID NETWORK INTERFACE DEVICE NTS NOT TO SCALE OC ON CENTER OC x OPTICAL CARRIER (OC1, OC3, OC12, ETC.) OF OPTICAL FIBER OFE OWNER FURNISHED EQUIPMENT OSP OUTSIDE PLANT PABX PRIVATE AUTOMATIC BRANCH EXCHANGE PB PULL BOX PBB PRIMARY BUS BAR PBX PRIVATE BRANCH EXCHANGE PNL PANEL POE POINT OF ENTRY (TELECOMMUNICATIONS SERVICES) POE POWER OVER ETHERNET POP POINT OF PRESENCE (TELECOMMUNICATIONS) POTS PLAIN OLD TELEPHONE SERVICE (LOOP START TIP & RING) 2 ABBREVIATIONS STANDARD STRUCTURED CABLING SYMBOLS STANDARD WALL MOUNTED TELECOMMUNICATIONS OUTLET (2) CAT6 UTP CABLES (UON BY #) 1. LOW-VOLTAGE CONTRACTOR MUST REVIEW AND COMPLY WITH SOUND TRANSIT DESIGN REQUIREMENTS. 2. PHYSICAL LOCATION OF OUTLETS AND OTHER TELECOMMUNICATIONS COMPONENTS ARE APPROXIMATE AND SUBJECT TO BE DETERMINED IN FINAL DESIGN. 3. CONTRACTOR TO COORDINATE AND OBTAIN WRITTEN AUTHORIZATION FROM OWNERSHIP PRIOR TO ANY INTERRUPTION OF ELECTRICAL OR TELECOMMUNICATIONS SERVICES. 4. LOW-VOLTAGE CONTRACTOR IS RESPONSIBLE FOR RESTORATION OF DAMAGE TO FIREPROOFING, FINISHES OR STRUCTURE CAUSED BY LOW-VOLTAGE CONTRACTOR. RESTORATION SHALL BE TO SAME CONDITION AS BEFORE DAMAGE OCCURRED. LOW-VOLTAGE CONTRACTOR SHALL OBTAIN WRITTEN ACCEPTANCE OF RESTORATION FROM OWNERSHIP. 5. EQUIPMENT AND DEVICE MOUNTING. LOW-VOLTAGE CONTRACTOR SHALL USE A FASTENING SYSTEM SUITABLE FOR THE ANTICIPATED LOADS AND THE STRENGTH OF THE SUPPORTING STRUCTURE. COORDINATE WITH OWNER REGARDING WEIGHT AND LOCATION OF EQUIPMENT TO BE MOUNTED TO STRUCTURE, ON WALLS, IN RACKS OR IN ENCLOSURES. LOW-VOLTAGE CONTRACTOR MUST CONSULT STRUCTURAL ENGINEER FOR RECOMMENDED FASTENING SYSTEM FOR NON- STANDARD CONDITIONS. 6. CONTRACTOR TO PROVIDE AND INSTALL FOUR-INCH (4") FIRE RATED SLEEVE PENETRATIONS IN RE- ENTERABLE FIRE-RATED PATHWAYS. 7. HORIZONTAL CABLING IN EITHER OPEN OR NON-CONTIGUOUS PATHWAYS SHALL NOT BE BUNDLED. GENERAL NOTES SECURITY SYMBOLS CARD READER -REQUIRES SINGLE GANG BOX, 3/4" CONDUIT STUBBED FROM SINGLE GANG BOX ROUTED TO SECURITY PANEL LOCATION. (1) TYPE E CABLE PER LOCATION, UON DOOR CONTACT -1/2" CONDUIT STUB IN FRAME 6" FROM LEADING EDGE OF DOOR, UON REQUIRES ONE (1) TYPE D CABLE PER LOCATION, UON ELECTRIFIED STRIKE -1/2" CONDUIT STUB FROM ELECTRIC STRIKE TO J BOX, UON REQUIRES ONE (1) TYPE B CABLE PER LOCATION, UON ELECTRICAL LOOKING DEVICES SPECIFIED BY OTHER, SHOWN FOR INTERCONNECTION WIRELESS CARD READER W PUSH BUTTON DURESS ALARM INTERCOM SECURITY CAMERA -PROVIDE (1) CATEGORY 6 UTP CABLE TO EACH LOCATION. PROVIDE HEATER AND HEATER POWER FOR CAMERAS. DOOR RELEASE PP PATCH PANEL PR PAIR PVC POLYVINYL CHLORIDE COMMUNICATIONS RCDD REGISTERED DISTRIBUTION DESIGNER (BICSI) RF RADIO FREQUENCY RFI RADIO FREQUENCY INTERENCE RG RADIO GUIDE (COAXIAL CABLE) RJ REGISTERED JACK RJ45 8-POSITION, 8-PIN MODULAR CONNECTOR RM ROOM RMC RIGID METAL CONDUIT RU RACK UNIT (1RU=1.75") SBB SECONDARY BUS BAR SM SINGLE-MODE ScTP SCREENED TWISTED PAIR STP SHIELDED TWISTED PAIR T1, T3 INTEGRATED SERVICES DIGITAL NETWORK (ISDN) CKT TBB TELECOMMUNICATIONS BONDING BACKBONE TBD TO BE DETERMINED TEMP TEMPORARY TSER TELECOMMUNICATIONS SERVICE ENTRANCE ROOM TEL TELECOMMUNICATIONS TELCO TELEPHONE (CARRIER) COMPANY TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION TR TELECOMMUNICATIONS ROOM TSER TELECOM SERVICE ENTRANCE ROOM (SEE POE) TYP TYPICAL TV TELEVISION TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR UG UNDERGROUND UL UNDERWRITERS LABORATORIES INC UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY USOC UNIVERSAL SERVICE ORDER CODE (TELECOM) UTP UNSHIELDED TWISTED PAIR VA VOLT-AMPERE V VOLT W WATT WAIO WORK AREA INFORMATION OUTLET WAN WIDE AREA NETWORK WAP WIRELESS ACCESS POINT WP WATERPROOF XFMR TRANSFORMER N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-T-v2020.rvt2/7/2022 1:41:30 PM12" = 1'-0" 405 128 0 AE 0054-17 Designer Author Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-ETN501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL ELECTRICAL TECHNOLOGY LEGENDS AND ABBREVIATIONS BRT-405-ETN500 CRCRCR CR CR CR CRCRCRES ES ESESCRESESESESESESA D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 C B 405-ETE501 1 2 2 222222222222222 22 2 2 2 2 2 2 2 2 2 2 2 2222222222 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 22 22 2 2 2 2 2 2 2 2 4 4 4 1 2 5 55 5 6 6 6 N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-T-v2020.rvt2/7/2022 1:41:31 PM1/16" = 1'-0" 405 129 0 AE 0054-17 Designer Author Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-ETP501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL ELECTRICAL TECHNOLOGY PLAN - LEVEL 1 BRT-405-ETP500 SCALE: 1/16" = 1'-0" TECHNOLOGY PLAN - LEVEL 1 & 1.5 1 SHEET NOTES: 1. PROVIDE POWERING FOR SECURITY CAMERAS. 2. PROVIDE HEATING FOR SECURITY CAMERAS. 3. PLACE CARD READERS ON THE HANDLE SIDE OF THE DOOR. 4. CABLES FROM DEVICES SHALL BE PLACED IN CONDUIT TO THE NEAREST TELECOMMUNICATIONS ROOM. 5. PROVIDE BACKBONE PATHWAYS FROM MDF TO EACH IDF. PROVIDE IN CONDUIT OUTSIDE TELECOM MDF AND IDFs. PROVIDE 100% GROWTH AND SPARE CAPACITY. NUMBERED NOTES: 1 PROVIDE CAMERA WITH VIEW OF ELEVATOR WAITING AREA AND STAIRS. 2 PROVIDE CAMERA WITH VIEW OF TICKET VALIDATION MACHINES. 3 COORDINATE CABLE QUANTITY AND LOCATION WITH TICKET MACHINES PROVIDED. 4 PROVIDE OUTLETS IN QUANTITY AS REQUIRED TO ACCOMMODATE SECURITY MONITORING. 5 PROVIDE CAMERAS WITH VIEW OF ENTRY AND EXIT AISLES. 6 COORDINATE LOCATION AND QUANTITY OF CABLES WITH EV CHARGING DEVICE REQUIREMENTS. (TYPICAL) CRCR ES ES ELEV#2 ELEV#1 BTP120202 BTP120201 BTP120203 STR#2 STR#1 A D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 C B 405-ETE501 3 405-ETE501 2 2 22 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-T-v2020.rvt2/7/2022 1:41:34 PM1/16" = 1'-0" 405 130 0 AE 0054-17 Designer Author Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-ETP502PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL ELECTRICAL TECHNOLOGY PLAN - LEVEL 2 BRT-405-ETP500 SCALE: 1/16" = 1'-0" TECHNOLOGY PLAN - LEVEL 2 & 2.5 1 SHEET NOTES: 1. PROVIDE POWER FOR SECURITY CAMERAS. 2. PROVIDE HEATING FOR SECURITY CAMERAS. 3. CABLES FROM DEVICES SHALL BE PLACED IN CONDUIT TO THE NEAREST TELECOMMUNICATIONS ROOM. 4. PROVIDE BACKBONE PATHWAYS FROM MDF TO EACH IDF. PROVIDE IN CONDUIT OUTSIDE TELECOM MDF AND IDFs. PROVIDE 100% GROWTH AND SPARE CAPACITY. NUMBERED NOTES: 1 COORDINATE LOCATION AND QUANTITY OF CABLES WITH EV CHARGING DEVICE REQUIREMENTS. (TYPICAL) ELEV#2 ELEV#1 STR#1 STR#2 A D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 C B N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-T-v2020.rvt2/7/2022 1:41:36 PM1/16" = 1'-0" 405 131 0 AE 0054-17 Designer Author Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-ETP503PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL ELECTRICAL TECHNOLOGY PLAN - LEVEL 3 BRT-405-ETP500 SCALE: 1/16" = 1'-0" TECHNOLOGY PLAN - LEVEL 3 & 3.5 1 CRCR ES ES ELEV#2 ELEV#1 BTP120402 BTP120401 BTP120403 STR#2 STR#1 A D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 C B 405-ETE501 5 405-ETE501 4 N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-T-v2020.rvt2/7/2022 1:41:38 PM1/16" = 1'-0" 405 132 0 AE 0054-17 Designer Author Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-ETP504PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL ELECTRICAL TECHNOLOGY PLAN - LEVEL 4 BRT-405-ETP500 SCALE: 1/16" = 1'-0" TECHNOLOGY PLAN - LEVEL 4 & 4.5 1 SHEET NOTES: 1. PROVIDE POWERING FOR SECURITY CAMERAS. 2. PROVIDE HEATING FOR SECURITY CAMERAS. 3. CABLES FROM DEVICES SHALL BE PLACED IN CONDUIT TO THE NEAREST TELECOMMUNICATIONS ROOM. 4. PROVIDE BACKBONE PATHWAYS FROM MDF TO EACH IDF. PROVIDE IN CONDUIT OUTSIDE TELECOM MDF AND IDFs. PROVIDE 100% GROWTH AND SPARE CAPACITY. 134132 ELEV#2 ELEV#1 STR#1 STR#2 A D 1 1.6 2 3 4 5 6 7 8 9 10 11 12 13 C B N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-T-v2020.rvt2/7/2022 1:41:40 PM1/16" = 1'-0" 405 133 0 AE 0054-17 Designer Author Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-ETP505PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL ELEC TRICAL TECHNOLOGY PLAN - LEVEL 5 BRT-405-ETP500 SCALE: 1/16" = 1'-0" TECHNOLOGY PLAN - LEVEL 5 & 5.5 1 CRCRCR CR CR BTP120109 9 405-ETD501 1 MDF RACK ELEVATION 2 14 5 5 5 5 3 3 3 3 D 13 405-ETD501 3 25 6 D 1 1 2 3 5 D 13 3 25 6 D 1 2 3 1 5 N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-T-v2020.rvt2/7/2022 1:41:30 PM1/4" = 1'-0" 405 AE 0054-17 Designer Author Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-ETE501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL ELECTRICAL TECHNOLOGY ENLARGED PLANS BRT-405-ETE500 1/4" = 1'-0"1 ENLARGED MDF 1/4" = 1'-0"2 LEVEL 2 - SOUTH EAST IDF 1/4" = 1'-0"3 LEVEL 2 - SOUTH WEST IDF 1/4" = 1'-0"4 LEVEL 4 - SOUTH EAST IDF 1/4" = 1'-0"5 LEVEL 4 - SOUTH WEST IDF SHEET NOTES: 1. PROVIDE ARMORED OFM-4 MULTIMODE BACKBONE CABLING AND 12 OS-2 SINGLEMODE BACKBONE CABLING BETWEEN THE MDF AND EACH TELECOMMUNIATIONS ROOM IN THE GARAGE. 2. PROVIDE COPPER BACKBONE CABLING TO MEET DESIGN REQUIREMENTS. 3. PROVIDE ADDITIONAL CABLING TO OTHER STATION FACILITIES AS INDICATED ON TELECOMMUNICATIONS DRAWINGS. 4. PROVIDE GROUNDING AND BONDING PER TIA STANDARDS. 5. PROVIDE CABLE TRAY TO ROUTE ALL CABLES WITHIN TELECOMMUNICAITONS SPACES FROM THE CABLE ENTRY TO THE RACK LOCATIONS. 6. TERMINATE TELECOMMUNICATIONS CABLING ON PATCH PANELS. FIBER CABLING WILL BE TERMINATED IN FULLY ENCLOSED PATCH PANELS. 7. PROVIDE SEISMIC BRACING AS REQUIRED. 8. PROVIDE FIRE RETARDANT TREATED PLYWOOD ON 2 ADJACENT WALLS OF TELECOMMUNICATIONS ROOM FROM +6" AFF TO +90" AFF. 9. PROVIDE BACKBONE PATHWAYS FROM MDF TO EACH IDF. PROVIDE IN CONDUIT OUTSIDE TELECOM MDF AND IDFs. PROVIDE 100% GROWTH AND SPARE CAPACITY. NUMBERED NOTES: 1 CABLE TRAY FOR DISTRIBUTION OF TELECOMMUNICATIONS CABLING WITHIN THE TELECOMMUNICATIONS ROOM. 2 TELECOM GROUND BAR. 3 TELECOMMUNICATIONS RACK 19 INCH X 84 INCH, ATTACHED TO STRUCTURE. PROVIDE 8-INCH TO 10-INCH CABLE MANAGER BETWEEN EACH RACK AND AT BOTH ENDS OF EACH ROW. PROVIDE (2) EIGHT OUTLET HORIZONTAL DISTRIBUTION UNITS PER RACK CONNECT TO UPS. 4 PROVIDE SECURITY CAMERA IN MDF WITH VIEW OF ENTRY DOOR. 5 PROVIDE MINIMUM 36" CLEARANCE AT FRONT AND REAR OF TELECOMMUNICATIONS RACK. 6 PROVIDE (2)2" CONDUIT FROM IDF ROOM TO ADJACENT ROOM. TYPICAL FOR ALL SOUTHEAST IDF ROOMS. 134 LEVEL 1 0' -0" 9 BO3-TOG -3' -0" BO2-TOG -1' -4" LEVEL 1.5 5' -9" 2 1 1 1 1 LEVEL 2 11' -6" D LEVEL 2.5 16' -9" 1 2 N DRAWING NO.: FACILITY ID: SHEET No: REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE:LINE IS 1" ATFULL SCALEREVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION PRELIMINARYSOUTH RENTON TRANSIT CENTERML02/11/21 02/11/21 ML BIM 360://160363P3.003 - I-405 BRT & OMF Phase 3 Garage - R20/BRT-405-003-T-v2020.rvt2/7/2022 1:41:28 PM1/4" = 1'-0" 405 AE 0054-17 Designer Author Approver I-405 BRT CONTRACT UNIT DESCRIPTION 5 405-ETD501PHASE 3 - 30% SUBMITTALPHASE 3 - 30% SUBMITTAL TECHNOLOGY DETAILS BRT-405-ETD500 1/4" = 1'-0"1 MDF RACK ELEVATION 1/4" = 1'-0"2 TYPICAL FOR ALL IDFs (TYPICAL FOR ALL IDFs) NUMBERED NOTES: 1 TELECOMMUNICATIONS RACK 19 INCH X 84 INCH, ATTACHED TO STRUCTURE. PROVIDE 8-INCH TO 10-INCH CABLE MANAGER BETWEEN EACH RACK AND AT BOTH ENDS OF EACH ROW. PROVIDE (2) EIGHT OUTLET HORIZONTAL DISTRIBUTION UNITS PER RACK CONNECT TO UPS. 2 CABLE TRAY FOR DISTRIBUTION OF TELECOMMUNICATIONS CABLING WITHIN THE TELECOMMUNICATIONS ROOM. 135