Loading...
HomeMy WebLinkAboutRC 20170705001768 ,� . 20170705001768 PAGE-001 OF 007 RECORDING RE iJESTED BY AND 07/05/2017 is:ae Q KING COUNTY, WA WHEN RECORDED MAIL TO: CITY CLERK'S OFFICE CITY OF RENTON 1055 SOUTH GRADY WAY RENTON, WA 98057 DECLARATION OF COVENANT FOR MAINTENANCE AND INSPECTION OF FLOW CONTROL BMPS Grantor: Conner Homes at Teravista, LLC Grantee: City of Renton LegalDescription: �T �6 4� ��P./�a�s� I qo?D 7 9'7� �'v� � - �-,��, 1,�� �'Q ss Additional Legal(s)on: Assessor's Tax Parcel ID#: ��5��— ��6� IN CONSIDERATION of the approved City of Renton(check one of the following)� residential building permit, ❑ commercial building permit, ❑ clearing and grading permit, ❑ subdivision permit,or ❑ short subdivision permit for Application File No.LUA/SWP LUA08-043 relating to the real property("Property")described above,the Grantor(s),the owner(s)in fee of that Property,hereby covenants(covenant)with City or Renton,a political subdivision of the state of Washington,that he/she(they)will observe, consent to,and abide by the conditions and obligations set forth and described in Paragraphs 1 through 8 below with regard to the Property. Grantor(s)hereby grants(grant), covenants(covenant), and agrees(agree)as follows: 1. Grantor(s)or his/her(their)successors in interest and assigns("Owners")shall retain,uphold, and protect the stormwater management devices, features,pathways,limits,and restrictions,known as flow control best management practices("BMPs"),shown on the approved Flow Control BMP Site Plan for the Property attached hereto and incorporated herein as Exhibit A. 2. The Owners shall at their own cost,operate,maintain,and keep in good repair,the Property's BMPs as described in the approved Design and Maintenance Details for each BMP attached hereto and incorporated herein as E�ibit B. 3. City or Renton shall provide at least 30 days written notice to the Owners that entry on the Properiy is planned for the inspection of the BMPs. After the 30 days,the Owners shall allow the City of Renton to enter for the sole purpose of inspecting the BMPs. In lieu of inspection by the City,the Owners may elect to engage a licensed civil engineer registered in the state of Washington who has expertise in drainage to inspect the BMPs and provide a written report describing their condition. If the engineer option is chosen,the Owners shall provide written notice to the City of Renton within fifteen days of receiving the City's notice of inspection. Within 30 days of giving this notice,the Owners,or the engineer on behalf of the Owners,shall provide the engineer's report to the City of Renton. If the report is not provided in a timely manner as specified above,the City of Renton may inspect the BMPs without further notice. 4. If the City determines from its inspection, ar from an engineer's report provided in accordance with Paragraph 3,that maintenance,repair,restoration,and/or mitigation work is required for the BMPs, The City shall notify the Owners of the specific maintenance,repair,restoration,andlor mitigation work (Work)required under RMC 4-6-030. The City shall also set a reasonable deadline for completing the Work or providing an engineer's report that verifies completion of the Work. After the deadline has passed,the Owners shall allow the City access to re-inspect the BMPs unless an engineer's report has been provided verifying completion of the Work. If the work is not completed properly within the time frame set by the City,the City may initiate an enforcement action. Failure to properly maintain the BMPs is a violation of RMC 4-6-030 and may subject the Owners to enforcement under the RMC 1-3,including fines and penalties. , 5. Apart from performing routine landscape maintenance,the Owners are hereby required to obtain written approval from the City or Renton before performing any alterations or modifications to the BMPs. 6. Any notice or approval required to be given by one party to the other under the provisions of this Declaration of Covenant shall be effective upon personal delivery to the other party,or after three(3) days from the date that the notice or approval is mailed with delivery confirmation to the current address on record with each Party. The parties shall notify each other of any change to their addresses. 7. This Declaration of Covenant is intended to promote the efficient and effective management of surface water drainage on the Property,and it shall inure to the benefit of all the citizens of the City of Renton and its successors and assigns. This Declaration of Covenant sha11 run with the land and be binding upon Grantor(s),and Grantor's(s') successars in interest and assigns. 8. This Declaration of Covenant may be terminated by execution of a written agreement by the Owners and the City of Renton that is recorded by King County in its real property recards. _ / i 1 • IN WITNESS WHEREOF,this Declaration of Covenant for the Maintenance and Inspection of Flow Control BMPs is executed this ,�1�day of f"l��r�h ,20 /7 . ���I�C.c`--`�„/)"`/�G`""" GRANTOR, owner of the Property GRANTOR,owner of the Property STATE OF WASHINGTON ) COUNTY OF KING )ss. On this day personally appeared before me: ���1 (7 �I���y� ,to me known to be the individual(s)described in and who executed the within and foregoing instrument and acknowledged that they signed the same as their free and voluntary act and deed,for the uses and purposes therein stated. �'ti I �. Given under my hand and official seal this 2� d f ��L,1 ,20 � \����\\\\\\\11��� .� �P FF�k,tc�r��� �� _� ..,,,,,� g,�`� N "''��� �A �i ��2�/ G� Y �v_��SS\�ARxAGp���i�� �� Printed name � �;0 2� y `��'% i Notary Public in and for the State of Washington, � �" " � ~� = Z � residing at i '', �°Ug�,'` _�� S i . -, z°= � .� �QC�VG�e i,�/ �j',,,, ,;09\,,\� _ ���t���'OF W PS�����' M a ointment ex ires � ( �� ������� Y rr r �� t vass�m�fau I NO°05'32"E 45.00 � 5 � — � — CONI�T,ER � � . � — � N m H O M E S N m � o CONTACT: (425)455-9280 � � � 5 BSBL 5'BSBL M � 5.0' ������ �PATIO � a, I 5.0' � N � W � � 1 6 ° i 7 01a o � o � � N o � o LEGEND v � � � W z o GARAGE � � BSBL BUILDING SETBACK LINE Q a � CONNECT AT Z ESMT EASEMENT r1/ � DOWNSPOUT LP LIGHT POLE �L � � COVERED SD STORM DRAINAGE � I PORCH SS SANITARY SEWER UTIL UTILITY � 5.0' WM WATER METER 10'X2'X1.5' • PERFORATED ' '. PIPE TRENCH • �; N'� �•� o Pervious Area= 1,659sf --5.0'- •� —� � -� - - - .` p�y __� �� � , ' N Max Impervious = 2,447sf(60%) � 10.00 , � SD � �,,y 45.00 _' ..�..' � -�— NO°00'00"W WM � ,_' ..,' 0 � � LP �o ° ° 8"ROOF DRAIN � TRUNK TO w CATCH BASIN � H � 0 97TH�41�ENUE �. LEGAL DESCRIPTION: LOT 16,TALBOT&55TH AVE.PLAT, VOLUME , PAGES DATE: 11/21/2016 LOT ADDRESS: 19207 97TH AVENUE SOUTH g_Z� PARCEL No. 855660-0160 MODEL: 3513 0 10 2� 40 DRIVEWAY(DWY): ORIENTATION-RIGHT MAX.DWY SLOPE: 2% SCALE: 1�� = 2O� LOT AREA: 4,079 SF FOUNDATION: 1,645 SF PATIO(S)/PORCH(S): 177 SF D R A I N A G E P L A N F O R DRIVEWAY/WALKWAY: 399 SF L � T � � TOTAL IMPERVIOUS AREA(INCLUDING ROOF OVERHANGS: 2,420 SF(59.3°io� TA L B O T & 5 5T H AV E. P LAT 1 � EXH I B IT B Your property contains a stormwater management flow control BMP (best management practice) called a "perforated pipe connection,"which was installed to reduce the stormwater runoff impacts of some or all of the impervious surface on your property. A perforated pipe connection is a length of drainage conveyance pipe with holes in the bottom, designed to "leak" runoff, conveyed by the pipe, into a gravel filled trench where it can be soaked into the surrounding soil. The connection is intended to provide opportunity for infiltration of any runoff that is being conveyed from an impervious surface (usually a roof)to a local drainage system such as a ditch or roadway pipe system. The size and composition of the perforated pipe connection as depicted by the flow control BMP site plan and design details must be maintained and may not be changed without written approval either from the King County Water and Land Resources Division or through a future development permit from King County. The soil overtop of the perforated portion of the system must not be compacted or covered with impervious materials. �4 � S FICURE C.2.11..� PERFOILaTED PIPE CONNECTTON F�R A SI\GLE FAI�IILY RESLDE�!'CE rancfom fill ---�_ \��\����f�����`\��\'� filter fa6ric �" �f��\ \�\���, � �� �� � �� �� ��f � / f / / / /. a �� 6 perfpipe 18"PT1iI1 v'p4o Q�p°a9a Q°I o �n�« j 1 f2"_3I4�washed rack O O(] q�0O4OppQu' q," no q o ea Q Q a e o➢ a o P °ap o ao V� �q � �4Q 000po L16a ooa �24"min—+I TRENCH X-SECTION NTS s�ope —► to road drainage system 2�x j o' �level trench w/perf pipe PLAN VIEW OF R�QF NTS