Loading...
HomeMy WebLinkAboutD_LUA22-000250_v3DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT PLANNING DIVISION MODIFICATION OF RESIDENTIAL DESIGN REQUIREMENTS FOR PROJECTS WITHIN THE R -6 ZONE EVALUATION FORM & DECISION An “X” is shown in the applicable residential design requirement box. When an alternative is employed that requires a modification, the staff evaluation is written on the lines below. The decision to approve or deny the requested modification can be found at the conclusion of this form. PROJECT NAME: PR22-000117 G. Singh Investments LLC Remodel/Addition LAND USE FILE NUMBER: LUA22-000250, MOD PROJECT MANAGER: Andrew Van Gordon, Associate Planner APPLICANT: Elevation Home Design, Attn: Mary Kay Everson, 2102 E. Main Ave, Unit 105, Puyallup, WA 98372 ZONING DESIGNATION: Residential-6 Zone (R-6) PROJECT LOCATION: 16842 – 124th Ave SE (Parcel Number 1432400030) SUMMARY OF REQUEST: The applicants propose a 720-square foot single story expansion located at the rear of the existing residence located at 16842 – 124th Ave SE (parcel number 1432400030) within the R-6 zone. The expansion exceeds a value of $50,000 and requires the entirety of the structure comply with the standards of RMC 4-2-115, “Residential Design and Open Space Standards”. The applicants are requesting a determination that the guidelines of the Residential Design Standards, specifically the “Primary Entry” element of the Residential Design component of RMC 4-2-115E.3. are satisfied with the requested modification. 1. Primary Entry Both of the following are required: The entry shall include a porch or stoop with a minimum depth of five feet (5’) and minimum height of 12 inches (12”) above grade. Alternative that meets guidelines (Explain) The front entry faces 124th Ave SE. The applicants are proposing to retain the existing front door and walkway with a revised overhang (Exhibit 1). An approximately five-foot deep by eight-foot wide (5’x8’) at grade slab is located at the front entrance with a three-foot deep by five and a half foot wide (3’x5.5’) overhang above the slab (Exhibit 2). The front entrance is 10 inches (10”) above the slab. (Exhibit 3) A three-foot wide by 16 feet long (3’x16’) sidewalk connects the slab to the driveway. The existing residence is nonconforming to the R-6 front yard setbacks. At its closest, the residence encroaches eight feet (8’) into the 25-foot front yard setback. DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF City of Renton Department of Community & Economic Development Modification of Residential Design Requirements 16842-124th Ave SE Modification LUA22-000250, MOD Permit Date: August 11, 2022 Page 2 of 3 The northern portion of the front façade is two feet (2’) closer to the street than the southern portion of the front façade. The front entrance is on the southern portion but adjacent to the point where the façade is offset. A new dormer feature on the front facade is proposed that would be perpendicular to the home’s primary roof ridgeline . The front façade improvements do not alter the existing footprint within the front yard setback of the residence. The dormer feature creates an overhang extending three feet (3’) in depth over the slab. The overhang maintains the 8-foot encroachment into the front yard setback. When looking at the front façade, the dormer feature leads the eye down the overhang toward the front door. By drawing one’s eye towards the door it becomes the focal point along the front. The slab extends three feet (3’) beyond the northern portion of th e front façade. The slab by virtue of its size and location acts as a space for social interaction separate from the walkway. Porches and stoops are permitted to project into front setbacks up to eight feet (8’) within the R-6 zone (RMC 4-2-110A). A porch or stoop five feet (5’) in depth on the residence would create a 10-foot encroachment into the front yard setback and would require a variance. Staff finds the proposed entry feature is an improvement to the existing entry as the overhang creates a focal point for the entrance, and the existing slab allows for a space for social interaction. Therefore, the proposal meets the primary entry guidelines of the Residential Design element set forth in RMC 4 -2-115E.3. RMC 4-2-115A2, CRITERIA FOR MODIFICATION OF RESIDENTIAL DESIGN STANDARDS: Renton Municipal Code, section 4-2-115, lists elements that are required to be included in all residential development in the zones stated in subsection B of this Section. Each element includes both standards and guidelines. Standards are provided for predictability. These standards specify a prescriptive manner in which the requirement can be met. Guidelines for each element are provided for flexibility. These guidelines provide direction for those who seek to meet the required element in a manner that is different from the standards. a. The determination as to the satisfaction of the requirement through the use of the guidelines is to be made by the Community and Economic Development Administrator when no other permit or approval requires Hearing Examiner review. b. When it has been determined that the proposed manner of meeting the design requirement through guidelines is sufficient, the applicant shall have satisfied that design requirement. DECISION The proposal satisfies the criteria listed in RMC 4-2-115A2 for approval of residential design modifications. Other design elements or representations, provided within the submitted application materials, are excluded from this approval and would be subject to the Renton Municipal Code in effect at the time of building permit application. Therefore, the 16842 - 124th Ave SE Modification, LUA22-000250, MOD is Approved . DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF City of Renton Department of Community & Economic Development Modification of Residential Design Requirements 16842-124th Ave SE Modification LUA22-000250, MOD Permit Date: August 11, 2022 Page 3 of 3 SIGNATURE & DATE OF DECISION: ________________________________________ ____________________________________ Vanessa Dolbee, Planning Director Date RECONSIDERATION: Within 14 days of the decision date, any party may request that the decision be reopened by the approval body. The approval body may modify hi s decision if material evidence not readily discoverable prior the original decision is found or if he finds there was misrepresentation of fact. After review of the reconsideration request, if the approval body finds sufficient evidence to amend the original decision, there will be no further extension of the appeal period. Any person wishing to take further action must file a formal appeal within the 14-day appeal time frame. APPEALS: Appeals of permit issuance must be filed in writing on or before 5:00 p.m. on August 25, 2022. An appeal of the decision must be filed within the 14-day appeal period (RCW 43.21.C.075(3); WAC 197- 11-680). Due to the ongoing state of emergency enacted by Governor’s Proclamation 20 -28.14 (and as amended), the City Clerk’s Office is working remotely. For that reason, appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov or delivered to City Hall 1st floor Lobby Hub Monday through Friday. The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date if your appeal is submitted electronically. Appeal s to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov. Exhibits: 1) Modification Evaluation Form 2) Site Plan 3) Elevations cc: G Singh Investments LLC DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF 8/11/2022 | 4:29 PM PDT