HomeMy WebLinkAboutEX3_P_Final_Layout_11x17__220404_v2Existing Space Proposed Space Open Below --------------------------------- Total Conditioned Area Existing Garage --------------------------------- Total Unconditioned Area --------------------------------- Total Areas 1147 Sq.Ft. 807 Sq.Ft. 0 Sq.Ft. ------------------- 1955 Sq.Ft. 167 Sq.Ft. ------------------- 167 Sq.Ft. ------------------- 2122 Sq.Ft. Square Foot Totals ("Open Below" is Space with No Stairs Underneath Open Area and is already removed from Floor Sq Ft Totals) Hebrews 3:4 (NIV) - For every house is built by someone, but God is the builder of everything. Drafting Manager: Jared Baehmer Elevation Home Designs 2102 E Main #105 Puyallup, WA 98372 866.657.4371 CAD Technician: Logan Harman Engineer of Record: Ercin Sahin, P.E. Structural Works, PLLC 1412 Beach Dr NE #A Tacoma, WA 98422 253.533.0835 Design Criteria & Loads Roof Snow Load: Floor Live Load: Deck Live Load: Wind Speed (ASD): Wind Speed (ULT): Exposure: Seismic Zone: Frost Depth: 25 LBS 40 LBS 60 LBS 85 MPH 110 MPH B D 1'-0" 2018 International Building Code (IBC) 2018 International Residential Code (IRC) 2018 Washington State Energy Code (WSEC) 3D Isometric Drawings are for illustration ONLY! N/A U-Factor (A)R-Value (A)All Climate Zones 0.042 Ceiling R-Value (E) Below Grade Wall (C,H) N/A Floor R-Value Fenestration U-Factor (B) Skylight U-Factor (B) Wood Frame Wall (G,K) Slab (D,F) R-Value & Depth N/A 49 (J) 30 (G) 21 INT 10/15/21 INT+TB 0.50 10, 2ft 0.30 0.056 0.026 0.029 A) R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table RA101.4 shall not be less than the R-value specified in the table B) The fenestration U-factor column excludes skylights. C) “10/15/21 + 5TB” means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. “10/15/21 + 5TB” shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. “5TB” means R-5 thermal break between floor slab and basement wall. D) R-10 continuous insulation is required under heated slab-on-grade floors. See Section R402.2.9.1. E) For single rafter or joist-vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth extends over the top plate of the exterior wall. F) R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall meet the requirements for thermal barriers protecting foam plastics. G) For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for climate zone 5 of ICC 400. H) Int. (intermediate framing) denotes framing and insulation as described in Section A103.2.2 including standard framing 16 inches on center, 78 percent of the wall cavity insulated and headers insulated with a minimum of R-10 insulation. Option Description Credit (R2) 2018 WA State Energy Code Information Fuel Normalization Credits for the 2018 WSEC 2 For an initial heating system using a heat pump that meets federal standards for the equipment listed in Table C403.3.2(1)C or C403.3.2(2) or Air to water heat pump units that are configured to provide both heating and cooling and are rated in accordance with AHRI 550/590 1.0 (1.0) 3.2 Air-source centrally ducted heat pump with minimum HSPF of 9.5. To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 1.0 (N/A) 5.4 Water heating system shall include one of the following: Electric heat pump water heater meeting the standards for Tier I of NEEA’s advanced water heating specification or For R-2 occupancy, electric heat pump water heater(s), meeting the standards for Tier I of NEEA’s advanced water heating specification, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the water heater equipment type and the minimum equipment efficiency. 1.5 (2.0) Option Description Energy Credits for the 2018 WSEC Credit (R2) 3D Isometric Drawings are for illustration ONLY! 3D Isometric Drawings are for illustration ONLY!16842 124th Ave SERenton, WA 98058253-222-1010Parcel # - 1432400030G Singh Investments LLCPrinted On: 1/22/2022 07:39:00 Sheet: Elevation Home Designs Job # : 21-0217Disclaimers:---These plans are exclusive property of Elevation Home Designs (EHD) and may not be sold to any personor business without expressed written consent of EHD. These plans are for one (1) time use only for EHD'scustomer - G Singh Investments LLC and to be built on the customer's site at 16842 124th Ave SE inRenton, WA 98058.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation Home Designs. Written permission must be obtained andgranted prior to any use and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizCASCADE VISTA ADD LESS C & M RGTS PLat Block: 1 Plat Lot: 6 ** This is not a survey. All Property Lines, Corners and Dimensions, as shown, are from information supplied by the homeowner or county web sites. No Liability is assumed for variances ascertained by actual or more recent surveys. Sheet Index Label Pg #Title A0.0 1 Project Cover Sheet A1.1 2 1st Floor Plan A1.2 3 2nd Floor Plan A2.1 4 Elevations A2.2 5 Elevations A3.1 6 Cross Sections S0.0 7 Structrual Notes S1.1 8 Foundation Plan S1.2 9 1st Flr Joist Framing S2.1 10 1st Floor Framing S2.2 11 1st Floor Shearwall S3.1 12 Roof Framing S4.1 13 Structural Details S4.2 14 Structural Details S4.3 15 Structural Details Project Information Layout Sheet # 1 of 15 Project Cover Sheet A0.0 Legal Description Applicable Codes RECEIVED PLANNING DIVISION 06/29/2022 AVanGordon DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF 16842 124th Ave SERenton, WA 98058253-222-1010Parcel # - 1432400030G Singh Investments LLCPrinted On: 1/22/2022 07:39:00 Sheet: Elevation Home Designs Job # : 21-0217Disclaimers:---These plans are exclusive property of Elevation Home Designs (EHD) and may not be sold to any personor business without expressed written consent of EHD. These plans are for one (1) time use only for EHD'scustomer - G Singh Investments LLC and to be built on the customer's site at 16842 124th Ave SE inRenton, WA 98058.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation Home Designs. Written permission must be obtained andgranted prior to any use and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizTub/Shower TD10 3468W01 5030 XOW02 5030 XO 9070 Garage OHDW07 3030 XOW05 6040 XO E01 3068 W03 5030 XO D01 2868 D04 2868 40 BypassD07 2668D06 28685068 40 BypassE02 3068806840 BypassW09 4040 XO W04 3030 XO W06 60610 #Evaluation Error# TG W08 3030 XO 1st Floor Plan - EHD-1019481-S As Built Scale: 1/4 in = 1 ft *** Scale Only on 24x36 or 30x42 Size Paper. Smaller Size Paper will be Not To Scale *** Bedroom #1 12'-1" x 10'-11" 7'-6" Plate Height Bedroom #2 8'-11" x 10'-11" 7'-6" Plate Height Bedroom #3 13'-8" x 8'-7" 7'-6" Plate Height Living Room 17'-7" x 12'-5" 9' Plate Height Kitchen 10'-3" x 8'-8" 7'-6" Plate Height Slab 10'-5" x 21'-4" 9'-3" Plate Height 1 Car Garage 10'-9" x 21'-4" 7'-6" Plate Height LIVING ROOM KITCHEN Demo Walls A A2.1 B A2.1 C A2.2 D A2.2 Layout Sheet # 2 of 15 1st Floor Plan A1.1 DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF 16842 124th Ave SERenton, WA 98058253-222-1010Parcel # - 1432400030G Singh Investments LLCPrinted On: 1/22/2022 07:39:00 Sheet: Elevation Home Designs Job # : 21-0217Disclaimers:---These plans are exclusive property of Elevation Home Designs (EHD) and may not be sold to any personor business without expressed written consent of EHD. These plans are for one (1) time use only for EHD'scustomer - G Singh Investments LLC and to be built on the customer's site at 16842 124th Ave SE inRenton, WA 98058.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation Home Designs. Written permission must be obtained andgranted prior to any use and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizExterior Room Schedule Room Name Floor Finish Ceiling Height Sq Ft**Dimensions** 1 Car Garage (E)Flooring - Concrete 111 5/8"167 11'-10" x 12'-2" Slab Flooring - Concrete N/A 228 10'-5" x 21'-0" 1st Floor Room Schedule Room Name Floor Finish Ceiling Height Sq Ft**Dimensions** Bath #1 (E)Flooring - Tile 91 1/8"74 7'-11" x 8'-5" Bath #2 (P)Flooring - Tile 91 1/8"80 9'-3" x 7'-7" Bath #3 (P)Flooring - Tile 91 1/8"71 6'-9" x 8'-8" Bedroom #1 (E)Flooring - Carpet 91 1/8"117 9'-10" x 10'-9" Bedroom #2 (E)Flooring - Carpet 91 1/8"107 8'-9" x 10'-9" Bedroom #3 (E)Flooring - Carpet 91 1/8"121 12'-9" x 8'-7" Bedroom #4 (P)Flooring - Carpet 91 1/8"165 11'-0" x 12'-2" Bedroom #5 (P)Flooring - Carpet 91 1/8"150 11'-11" x 11'-6" Bedroom #6 (P)Flooring - Carpet 91 1/8"163 12'-0" x 11'-6" Bedroom #7 (E)Flooring - Carpet 91 1/8"174 9'-4" x 15'-0" Closet #1 (E)Flooring - Carpet 91 1/8"13 1'-11" x 5'-4" Closet #2 (E)Flooring - Carpet 91 1/8"13 1'-11" x 5'-1" Closet #3 (E)Flooring - Carpet 91 1/8"19 4'-10" x 3'-1" Closet #4 (P)Flooring - Carpet 91 1/8"14 5'-7" x 1'-11" Closet #5 (P)Flooring - Carpet 91 1/8"20 2'-11" x 5'-5" Closet #6 (P)Flooring - Carpet 91 1/8"19 1'-11" x 7'-5" Closet #7 (P)Flooring - Carpet 91 1/8"15 6'-1" x 1'-11" Hallway (E)Flooring - Laminate 91 1/8"235 21'-9" x 12'-7" Kitchen (E)Flooring - Laminate 91 1/8"94 12'-1" x 7'-4" Laundry (P)Flooring - Vinyl 91 1/8"19 2'-9" x 5'-8" Living Room (E)Flooring - Laminate 91 1/8"180 17'-7" x 9'-9" Hallway (P)Flooring - Laminate 91 1/8"91 4'-2" x 11'-6" Totals:1954 *Ceiling Height for Garage/Basement is from Top of Slab to Top of Sill Plate ** All Square Footage, Room Dimensions & Ceiling Heights are Approximate Interior Door Schedule ** Contractor to Vertify Beam Lengths Number Status Size Floor Width Height Room Name Type Header Size Header Type Jamb Size Trim Size Hinge Side Swing Side Comments D01 New 3068 L IN 1 36 "80 "Bedroom #2 (E)/Hallway (E)Hinged -- None --3/4"x4 1/2"1/2"x3"L In D02 New 5068 L/R 1 60 "80 "Hallway (P)/Laundry (P)4 Dr. Bifold -- None --3/4"x4 1/2"1/2"x3"L/R In D03 New 3068 L IN 1 36 "80 "Hallway (P)/Bedroom #4 (P)Hinged -- None --3/4"x4 1/2"1/2"x3"L Out D04 New 3068 R IN 1 36 "80 "Hallway (P)/Bath #2 (P)Hinged -- None --3/4"x4 1/2"1/2"x3"R In D05 New 3068 L IN 1 36 "80 "Hallway (E)/Bedroom #5 (P)Hinged -- None --3/4"x4 1/2"1/2"x3"L Out D06 New 3068 L IN 1 36 "80 "Hallway (E)/Bedroom #6 (P)Hinged -- None --3/4"x4 1/2"1/2"x3"L Out D07 New 5068 L IN 1 60 "80 "Bedroom #7 (E)/Closet #7 (P)Slider -- None --3/4"x4 1/2"1/2"x3"L In D08 New 5068 R IN 1 60 "80 "Closet #4 (P)/Bedroom #4 (P)Slider -- None --3/4"x4 1/2"1/2"x3"R Out D09 New 3068 R IN 1 36 "80 "Bath #3 (P)/Hallway (E)Hinged -- None --3/4"x4 1/2"1/2"x3"R Out D10 New 3068 R IN 1 36 "80 "Bedroom #7 (E)/Hallway (E)Hinged -- None --3/4"x4 1/2"1/2"x3"R In D11 New 3068 L IN 1 36 "80 "Bedroom #1 (E)/Hallway (E)Hinged -- None --3/4"x4 1/2"1/2"x3"L In D12 New 5068 L/R 1 60 "80 "Bedroom #2 (E)/Closet #2 (E)4 Dr. Bifold -- None --3/4"x4 1/2"L/R In D13 New 5068 L/R 1 60 "80 "Closet #1 (E)/Bedroom #1 (E)4 Dr. Bifold -- None --3/4"x4 1/2"L/R Out D14 New 3068 L IN 1 36 "80 "Bath #1 (E)/Hallway (E)Hinged -- None --3/4"x4 1/2"1/2"x3"L Out D15 New 3068 R IN 1 36 "80 "Bedroom #3 (E)/Hallway (E)Hinged -- None --3/4"x4 1/2"1/2"x3"R In D16 New 3068 L IN 1 36 "80 "Bedroom #3 (E)/Closet #3 (E)Hinged -- None --3/4"x4 1/2"1/2"x3"L In D17 New 5068 L/R 1 60 "80 "Closet #5 (P)/Bedroom #5 (P)4 Dr. Bifold -- None --3/4"x4 1/2"1/2"x3"L/R Out D18 New 6068 L IN 1 72 "80 "Bedroom #6 (P)/Closet #6 (P)Slider -- None --3/4"x4 1/2"1/2"x3"L In Exterior Door Schedule ** Contractor to Vertify Beam Lengths Number Status Size Floor Width Height Sq Ft Room Name Header Size Header Type Jamb Size Trim Size Fire Tempered U-Factor Comments E01 New 3068 L EX 1 36 "80 "20.0 Hallway (P)3-1/2" x 7-1/4" x 3'-6"Lumber 3/4"x6 7/16"1/2"x3"0.2 E02 Existing 3068 L EX 1 36 "80 "20.0 Living Room (E)3-1/2" x 7-1/4" x 3'-6"Lumber 3/4"x6 7/16"1/2"x3"0.2 E03 New 3068 R EX 1 36 "80 "20.0 1 Car Garage (E)/Hallway (E)3-1/2" x 7-1/4" x 3'-6"Lumber 3/4"x6 1/2"1/2"x3"Yes 0.2 Totals:60.0 Garage Door Schedule ** Contractor to Vertify Beam Lengths Number Status Size Floor Width Height Sq Ft Room Name Header Size Header Type Jamb Size Trim Size Fire Tempered U-Factor Comments G01 Existing 9070 1 108 "84 "63.0 1 Car Garage (E)3-1/2" x 13-1/2" x 9'-6"Glulam 3/4"x4 15/16"1/2"x3"0 Window Schedule ** Verify Sizes & Lengths w/ Engineering if Applicable Number Status Window Info Floor Width Height Sq Ft Room Name**Header Size Header Type Top Height Trim Size Egress Tempered U-Factor Comments W01 New 5040 XO 1 60 "48 "20.0 Bedroom #3 (E)3-1/2" x 7-1/4" x 5'-3"Lumber 80"3/4"x3"Yes 0.27 W02 Existing 5030 XO 1 60 "36 "15.0 Bedroom #1 (E)3-1/2" x 7-1/4" x 5'-3"Lumber 80"3/4"x3"Yes 0.3 W03 Existing 5030 XO 1 60 "36 "15.0 Bedroom #2 (E)3-1/2" x 7-1/4" x 5'-3"Lumber 80"3/4"x3"Yes 0.3 W04 New 5040 XO 1 60 "48 "20.0 Bedroom #4 (P)3-1/2" x 7-1/4" x 5'-3"Lumber 80"3/4"x3"Yes 0.27 W05 New 5040 XO 1 60 "48 "20.0 Bedroom #5 (P)3-1/2" x 7-1/4" x 5'-3"Lumber 80"3/4"x3"Yes 0.27 W06 New 5040 XO 1 60 "48 "20.0 Bedroom #6 (P)3-1/2" x 7-1/4" x 5'-3"Lumber 80"3/4"x3"Yes 0.27 W07 New 5040 XO 1 60 "48 "20.0 Bedroom #7 (E)3-1/2" x 7-1/4" x 5'-3"Lumber 80"3/4"x3"Yes 0.27 W08 Existing 6040 XO 1 72 "48 "24.0 Living Room (E)3-1/2" x 7-1/4" x 6'-3"Lumber 80"3/4"x3"0.3 Totals:154.0 1955 Sq.Ft. 213.0 Sq.Ft. 10.9 % Floor Areas 1st Floor Living Area = Total Living Space = Total Glazing Area = Glazing Percentage = 1955 Sq.Ft. **Glazing Calc have Open Below Areas included. **Windows Located in Non-Heated Rooms are not included in Glazing Percentages Shower (ADA)TDWShower (ADA)T FurnTShower (ADA)Heat PumpH/P W/HW01 5040 XO Egress (P)W02 5030 XO Egress (E)W03 5030 XO Egress (E) 9070 Garage OHD (E) D01 3068 D11 3068 50685068D14 3068D15 3068D16 3068 W04 5040 XO Egress (P)506860 Bypass5068E01 3068 (P) W05 5040 XO Egress (P)W06 5040 XO Egress (P)D03 3068D04 3068 D05 3068 D06 3068 50 Bypass W07 5040 XO Egress (P)W08 6040 XO (E) E02 3068 (E) E03 3068 (P) 50 Bypass D09 3068D10 3068 CO SD SD SD SD SD SDCO SD SD SD SDCO 80 CFM (30 CFM Cont) 80 CFM (30 CFM Cont) 80 CFM (30 CFM Cont)100 CFM50 CFM 5' 5' 5' 1955 SQ FT 1st Floor Plan - EHD-1019481-S Proposed Scale: 1/4 in = 1 ft *** Scale Only on 24x36 or 30x42 Size Paper. Smaller Size Paper will be Not To Scale *** LIVING AREA BEDROOM #3 (E) CLOSET #3 (E) BEDROOM #2 (E) CLOSET #2 (E) CLOSET #1 (E) BEDROOM #1 (E) HALLWAY (E) Bedroom #1 (E) 9'-10" x 10'-9" 7'-6" Plate Height Flooring - Carpet Bedroom #2 (E) 8'-9" x 10'-9" 7'-6" Plate Height Flooring - Carpet Bedroom #3 (E) 12'-9" x 8'-7" 7'-6" Plate Height Flooring - Carpet 1 Car Garage (E) 11'-10" x 12'-2" 9'-3" Ceiling Height Flooring - Concrete LIVING ROOM (E)Living Room (E) 17'-7" x 9'-9" 7'-6" Plate Height Flooring - Laminate Bedroom #7 (E) 9'-4" x 15'-0" 7'-6" Plate Height Flooring - Carpet Bedroom #6 (P) 12'-0" x 11'-6" 7'-6" Plate Height Flooring - Carpet Bedroom #5 (P) 11'-11" x 11'-6" 7'-6" Plate Height Flooring - Carpet Bedroom #4 (P) 11'-0" x 12'-2" 7'-6" Plate Height Flooring - Carpet BEDROOM #4 (P)BEDROOM #5 (P)BEDROOM #6 (P) BATH #2 (P) Kitchen (E) 12'-1" x 7'-4" 7'-6" Plate Height Flooring - Laminate CLOSET #6 (P) CLOSET #5 (P) LAUNDRY (P) KITCHEN (E) BATH #3 (P) CLOSET #4 (P) 1 CAR GARAGE (E) 20 min. Fire Rated Door CLOSET #7 (P) HALLWAY (P) BEDROOM #7 (E) BATH #1 (E) A A2.1 B A2.1 C A2.2 D A2.2 A A3.1 A A3.1 B A3.1 B A3.1 Layout Sheet # 3 of 15 2nd Floor Plan A1.2 DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF 16842 124th Ave SERenton, WA 98058253-222-1010Parcel # - 1432400030G Singh Investments LLCPrinted On: 1/22/2022 07:39:00 Sheet: Elevation Home Designs Job # : 21-0217Disclaimers:---These plans are exclusive property of Elevation Home Designs (EHD) and may not be sold to any personor business without expressed written consent of EHD. These plans are for one (1) time use only for EHD'scustomer - G Singh Investments LLC and to be built on the customer's site at 16842 124th Ave SE inRenton, WA 98058.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation Home Designs. Written permission must be obtained andgranted prior to any use and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.biz*** Scale Only on 24x36 or 30x42 Size Paper. Smaller Size Paper will be Not To Scale *** Existing Proposed 24"16'-3"7'-7 1/8"18'-3"15'-2 1/2"12 1/2" -(1'-0") - Min Frost Depth Top of Wall Plate Above FFL - 7'-7 1/8" (7.59') Approximate Height Above FFL - 15'-2 1/2" (15.21') Minimum Grade Minimum 6" Grade to Wood Top of Sub Floor FFL - 0' (402.00') Continuous Ridge Vent Architectural Composition Roofing Class "B" Minimum Required w/ 7/16" Plywood Roof Sheathing 3/4" Cornerboard Horizontal Lap Siding Elevation A -EHD-1019481-S Proposed Scale: 1/4 in = 1 ft *** Scale Only on 24x36 or 30x42 Size Paper. Smaller Size Paper will be Not To Scale *** ExistingProposed -(1'-0") -Min Frost Depth Top of Wall Plate Above FFL - 7'-7 1/8" (409.59') Approximate Height Above FFL - 15'-2 1/2" (417.21') Minimum Grade Minimum 6" Grade to Wood Top of Sub Floor FFL - 0' (402.00') Continuous Ridge Vent Architectural Composition Roofing Class "B" Minimum Required w/ 7/16" Plywood Roof Sheathing 3/4" Cornerboard Horizontal Lap Siding 6" x 25-27" Tall FDN Wall w/ 6" x 12" Footing Elevation B - EHD-1019481-S Proposed Scale: 1/4 in = 1 ft24"16'-3"7'-7 1/8"18'-3"15'-2 1/2"12 1/2"Layout Sheet # 4 of 15 Elevations A2.1 DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF 16842 124th Ave SERenton, WA 98058253-222-1010Parcel # - 1432400030G Singh Investments LLCPrinted On: 1/22/2022 07:39:01 Sheet: Elevation Home Designs Job # : 21-0217Disclaimers:---These plans are exclusive property of Elevation Home Designs (EHD) and may not be sold to any personor business without expressed written consent of EHD. These plans are for one (1) time use only for EHD'scustomer - G Singh Investments LLC and to be built on the customer's site at 16842 124th Ave SE inRenton, WA 98058.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation Home Designs. Written permission must be obtained andgranted prior to any use and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.biz*** Scale Only on 24x36 or 30x42 Size Paper. Smaller Size Paper will be Not To Scale *** Proposed -(1'-0") - Min Frost Depth Top of Wall Plate Above FFL - 7'-7 1/8" (409.60') Approximate Height Above FFL - 15'-2 1/2" (417.21') Minimum Grade Minimum 6" Grade to Wood Top of Sub Floor FFL - 0' (402.00') Continuous Ridge Vent Architectural Composition Roofing Class "B" Minimum Required w/ 7/16" Plywood Roof Sheathing 3/4" Cornerboard Horizontal Lap Siding 6" x 25-27" Tall FDN Wall w/ 6" x 12" Footing Elevation C - EHD-1019481-S Proposed Scale: 1/4 in = 1 ft24"16'-3"7'-7 1/8"18'-3"15'-2 1/2"12 1/2"*** Scale Only on 24x36 or 30x42 Size Paper. Smaller Size Paper will be Not To Scale *** Existing Proposed -(1'-0") - Min Frost Depth Top of Wall Plate Above FFL - 7'-7 1/8" (409.59') Approximate Height Above FFL - 15'-2 1/2" (417.21') Minimum Grade Minimum 6" Grade to Wood Top of Sub Floor FFL - 0' (402.00') Continuous Ridge Vent Architectural Composition Roofing Class "B" Minimum Required w/ 7/16" Plywood Roof Sheathing 3/4" Cornerboard Horizontal Lap Siding 6" x 25-27" Tall FDN Wall w/ 6" x 12" Footing Elevation D -EHD-1019481-S Proposed Scale: 1/4 in = 1 ft24"16'-3"7'-7 1/8"18'-3"15'-2 1/2"12 1/2"Layout Sheet # 5 of 15 Elevations A2.2 DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF 16842 124th Ave SERenton, WA 98058253-222-1010Parcel # - 1432400030G Singh Investments LLCPrinted On: 4/3/2022 06:36:52 Sheet: Elevation Home Designs Job # : 21-0217Disclaimers:---These plans are exclusive property of Elevation Home Designs (EHD) and may not be sold to any personor business without expressed written consent of EHD. These plans are for one (1) time use only for EHD'scustomer - G Singh Investments LLC and to be built on the customer's site at 16842 124th Ave SE inRenton, WA 98058.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation Home Designs. Written permission must be obtained andgranted prior to any use and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.biz*** Scale Only on 24x36 or 30x42 Size Paper. Smaller Size Paper will be Not To Scale ***24"16'-3"7'-7 1/8"18'-3"15'-2 1/2"12 1/2" -(1'-0") - Min Frost Depth Top of Wall Plate Above FFL - 7'-7 1/8" (409.59') Approximate Height Above FFL - 15'-2 1/2" (417.21') Minimum 6" Grade to Wood Top of Sub Floor FFL - 0' (402.00') Pre-Manufactured Trusses @ " oc Continuous Ridge Vent Architectural Composition Roofing Class "B" Minimum Required w/ 7/ 16" Plywood Roof Sheathing 9 1/2" I-Joist @ 16" oc 6" x 25-27" Tall FDN Wall w/ 6" x 12" Footing Cross Section A - EHD-1019481-S Proposed Scale: 1/4 in = 1 ft *** Scale Only on 24x36 or 30x42 Size Paper. Smaller Size Paper will be Not To Scale *** -(1'-0") - Min Frost Depth Top of Wall Plate Above FFL - 7'-7 1/8" (409.59') Approximate Height Above FFL - 15'-2 1/2" (417.21') Minimum 6" Grade to Wood Top of Sub Floor FFL - 0' (402.00') Pre-Manufactured Trusses @ " oc Continuous Ridge Vent Architectural Composition Roofing Class "B" Minimum Required w/ 7/ 16" Plywood Roof Sheathing 9 1/2" I-Joist @ 16" oc 6" x 25-27" Tall FDN Wall w/ 6" x 12" Footing Cross Section B - EHD-1019481-S Proposed Scale: 1/4 in = 1 ft24"16'-3"7'-7 1/8"18'-3"15'-2 1/2"12 1/2"Layout Sheet # 6 of 15 Cross Sections A3.1 DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF 16842 124th Ave SERenton, WA 98058253-222-1010Parcel # - 1432400030G Singh Investments LLCPrinted On: 1/22/2022 07:39:01 Sheet: Elevation Home Designs Job # : 21-0217Disclaimers:---These plans are exclusive property of Elevation Home Designs (EHD) and may not be sold to any personor business without expressed written consent of EHD. These plans are for one (1) time use only for EHD'scustomer - G Singh Investments LLC and to be built on the customer's site at 16842 124th Ave SE inRenton, WA 98058.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation Home Designs. Written permission must be obtained andgranted prior to any use and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizLayout Sheet # 7 of 15 Structrual Notes S0.0 GENERAL NOTES AREA ROOF OTHER ROOMS FLOORS STAIRS DECKS DESIGN DEAD LOAD 15 PSF ACTUAL ACTUAL ACTUAL LIVE LOAD 25 PSF (SNOW) 40 PSF (2) 40 PSF (OR 300#/TREAD) 60 PSF (1)LIVE LOAD REDUCTION NOT PERMITTED EXCEPT AS NOTED IN IBC SECTION 1607.10. (2)30 PSF FOR SLEEPING AREAS LATERAL FORCES WIND: IBC - EXPOSURE CATEGORY = B - BASIC WIND SPEED, (3 SEC. GUST), VULT = 110 MPH - WIND IMPORTANCE FACTOR, Iw = 1.0 - OCCUPANCY BUILDING CATEGORY PER TABLE 1-1 = II - INTERNAL PRESSURE COEFFICIENT (ENCLOSED) = ± 0.18 -TOPOGRAPHIC FACTOR KZT = 1.00 SEISMIC: WELDING STRUCTURAL STEEL: WELD IN ACCORDANCE WITH "STRUCTURAL WELDING CODE" AWS D1.1. ELECTRODES: USE E70 ELECTRODES. GENERAL REQUIREMENTS ADHESIVE ANCHOR RODS: ASTM F1554, GRADE 36 UNLESS NOTED OTHERWISE. SEISMIC IMPORTANCE FACTOR, e = 1.0 RISK CATEGORY OF BUILDING PER TABLE 1.5-1 = D SPECTRAL RESPONSE ACCELERATIONS Ss = 1.39 & S1 = 0.47 SITE CLASS PER TABLE 20.3-1 = D DESIGN SPECTRAL RESPONSE ACCELERATIONS Sds = 0.93 SEISMIC DESIGN CATEGORY = D ANALYSIS PROCEDURE USED = SIMPLIFIED LATERAL FORCE ANALYSIS RESPONSE MODIFICATION FACTOR PER TABLE 12.2-1, R = 6.5 I CONCRETE ANCHORS: - ADHESIVE ANCHORS: HILTI HIT-HY 200 (ICC-ESR-3187) *CONCRETE SHALL BE A MINIMUM OF 21 DAYS OLD AT TIME OF INSTALLATION. *CONCRETE SHALL BE IN THE TEMPERATURE RANGE AS REQUIRED BY THE CONCRETE MANUFACTURER. *HOLE SHALL BY HAMMER-DRILLED ONLY. *HOLE SHALL BE DRY AT TIME OF INSTALLATION. *INSTALLER OF HORIZONTAL OR UPWARDLY INCLINED (ANY POSITION EXCEPT DIRECTLY DOWNWARD) ANCHORS SHALL ALSO BE CERTIFIED BY THE ACI/ CRSI ADHESIVE ANCHOR INSTALLER CERTIFICATION PROGRAM. STRUCTURAL STEEL DETAILING, FABRICATION AND ERECTION ALL WORKMANSHIP SHALL CONFORM TO THE AISC MANUAL OF STEEL CONSTRUCTION, 14TH EDITION. MATERIAL PROPERTIES WIDE FLANGE SECTIONS: ASTM A992 (Fy = 50 KSI) OTHER SHAPES AND PLATES: ASTM A36 (Fy = 36 KSI) TYP. U.N.O.; ASTM A572 (Fy = 50 KSI) WHERE INDICATED HOLLOW STRUCTURAL SECTIONS: RECTANGULAR & SQUARE - ASTM A500 GRADE B (Fy = 46 KSI) ROUND - ASTM A500 GRADE B (Fy = 42 KSI) STRUCTURAL STEEL PIPES: ASTM A53, GRADE B, TYPE E OR S (Fy = 35 KSI) MACHINE BOLTS (M.B.): ASTM A307, GRADE A ANCHOR BOLTS (A.B.): ASTM F1554, GRADE 55, UNLESS OTHERWISE NOTED, ASTM F1554, GRADE 105 WHERE INDICATED. ANY DISCREPANCIES FOUND AMONG THE DRAWINGS, THE SPECIFICATIONS, THESE GENERAL NOTES AND THE SITE CONDITIONS SHALL BE REPORTED TO THE ARCHITECT, WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING. ANY WORK DONE BY THE GENERAL CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE GENERAL CONTRACTOR'S RISK. THE GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE DIMENSIONS AMONG ALL DRAWINGS PRIOR TO PROCEEDING WITH ANY WORK OR FABRICATION. THE STRUCTURE HAS BEEN DESIGNED TO RESIST CODE SPECIFIED VERTICAL AND LATERAL FORCES AFTER THE CONSTRUCTION OF ALL STRUCTURAL ELEMENTS HAS BEEN COMPLETED. STABILITY OF THE STRUCTURE PRIOR TO COMPLETION IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THIS RESPONSIBILITY INCLUDES BUT IS NOT LIMITED TO JOB SITE SAFETY; ERECTION MEANS, METHODS, AND SEQUENCES; TEMPORARY SHORING, FORMWORK, BRACING; USE OF EQUIPMENT AND CONSTRUCTION PROCEDURES. CONSTRUCTION OBSERVATION BY THE STRUCTURAL ENGINEER IS FOR GENERAL CONFORMANCE WITH DESIGN ASPECTS ONLY AND IS NOT INTENDED IN ANY WAY TO REVIEW THE CONTRACTOR'S CONSTRUCTION PROCEDURES. STANDARDS ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) AS AMENDED AND ADOPTED BY THE LOCAL BUILDING OFFICIAL OR APPLICABLE JURISDICTION. APPLICABLE STRUCTURAL PROVISIONS: •2018 INTERNATIONAL BUILDING CODE (IBC) DESIGN CRITERIA VERTICAL LOADS SNOW: (MINIMUM ROOF SNOW LOAD = 25 PSF) Pg = 25 PSF = GROUND SNOW LOAD Pf = 0.7CeCt IsPg = FLAT ROOF SNOW LOAD Ps = CsPf = SLOPED ROOF SNOW LOAD Is = 1.0 Ce = 1.0, Ct = 1.0, Cs = VARIES THE BUILDING MEETS THE CRITERIA TO USE THE "SIMPLIFIED ENVELOPE PROCEDURE" PER ASCE 7-16. SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE SPECIFIED BELOW, SHALL BE SUBMITTED FOR APPROVAL A MINIMUM OF 2 WEEKS PRIOR TO BID, ALONG WITH CALCULATIONS THAT ARE PREPARED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER (LICENSED IN THE STATE IN WHICH THE PROJECT OCCURS) DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING EQUIVALENT PERFORMANCE VALUES (MINIMUM) OF THE SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE AND/OR STANDARD(S) AS REQUIRED BY THE BUILDING CODE. - SCREW ANCHORS: KWIK HUS-EZ (ICC ESR-3027) BY HILTI, INC. OR TITEN HD (ICC ESR-2713) BY SIMPSON STRONG TIE, INC. - EXPANSION ANCHORS: KWIKBOLT TZ (ICC ESR-1917) BY HILTI, INC. OR STRONG-BOLT 2 (ICC ESR-3037) BY SIMPSON STRONG TIE, INC. FINISH : STRUCTURAL STEEL SHALL BE PRIMER PAINTED, UNLESS NOTED OTHERWISE. WHERE STRUCTURAL STEEL IS NOTED TO BE GALVANIZED, IT SHALL BE HOT-DIP GALVANIZED IN ACCORDANCE WITH ASTM A123, A384, AND A385. CERTIFICATION : ALL WELDING SHALL BE PERFORMED BY WABO/AWS CERTIFIED WELDERS. WELDERS SHALL BE PREQUALIFIED FOR EACH POSITION AND WELD TYPE WHICH THE WELDER WILL BE PERFORMING. ITEM SLAB ON GRADE FOUNDATIONS - UNO STEM WALLS CONCRETE MIX NOTES: GROUT REINFORCING STEEL POST-INSTALLED ANCHORS DESIGN f'c (PSI) (AT 28 DAYS U.N.O.) 2500 2500 2500 MAX W/C RATIO 0.45 0.50 0.45 100 -- 100 AGGREGATE GRADING ASTM AASHTO 57 OR 67 1 NOTES CONCRETE FOUNDATION DESIGN CRITERIA SOIL BEARING PRESSURE: 1500 PSF (ASSUMED)* ACTIVE PRESSURE - RESTRAINED: 55 PCF +14H SEISMIC SURCHARGE (ASSUMED) ACTIVE PRESSURE - UNRESTRAINED: 35 PCF +6H SEISMIC SURCHARGE (ASSUMED) PASSIVE RESISTANCE: 200 PCF (INCLUDES F.O.S. ≥ 1.5) (ASSUMED) COEFFICIENT OF FRICTION: .35 (INCLUDES F.O.S. ≥ 1.5) (ASSUMED) FREE DRAINING BACKFILL MATERIAL FOR RETAINING & BASEMENT WALLS WITH A MAXIMUM DUST RATIO % PASSING U.S. NO. 200 SIEVE % PASSING U.S. NO. 40 SIEVE = 2/3 MAX. ALL FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH OR "STRUCTURAL BACKFILL". NATIVE EARTH BEARING SHALL BE SURFACE COMPACTED. AREAS OVER-EXCAVATED SHALL BE BACKFILLED WITH LEAN CONCRETE (F'c= 2000 PSI) OR "STRUCTURAL BACKFILL". AREAS DESIGNATED "STRUCTURAL BACKFILL" SHALL BE FILLED WITH APPROVED WELL-GRADED BANKRUN MATERIAL. MAXIMUM SIZE OF ROCK 4". FROZEN SOIL, ORGANIC MATERIAL AND DELETERIOUS MATTER NOT ALLOWED. COMPACT TO AT LEAST 95% OF ITS MAXIMUM DENSITY AS DETERMINED BY ASTM D1557. PROVIDE DRAINAGE AND DEWATERING AROUND ALL WORK TO AVOID WATER-SOFTENED FOOTINGS. A CLEAN, FREE DRAINING, WELL GRADED GRANULAR MATERIAL CONFORMING TO ASTM D2487 GW OR SW WHOSE MAXIMUM PARTICLE SIZE DOES NOT EXCEED 3/4" AND WHOSE FINES CONTENT (MATERIAL PASSING THE NO. 200 SIEVE) DOES NOT EXCEED 5%, CONCRETE: MODERATE WEATHERING POTENTIAL SHALL BE MADE WITH PORTLAND CEMENT SHALL BE MADE WITH PORTLAND CEMENT ASTM C-150 TYPE II OR TYPE I, COARSE AND FINE AGGREGATE ASTM C-33, WATER CLEAN AND POTABLE AND SHALL BE READY MIXED PER ASTM C-94. NO ALUMINUM (CONDUIT, MISCELLANEOUS ITEMS, ETC.) SHALL BE EMBEDDED IN ANY CONCRETE. COORDINATE FORMWORK AND FINISH TYPES ACCEPTABLE TO THE OWNER. 1. FIBROUS CONCRETE REINFORCEMENT SHALL BE "FIBERMESH" MANUFACTURED BY PROPEX CONCRETE SYSTEMS OR PRE-APPROVED EQUAL. DOSAGE SHALL FOLLOW MANUFACTURER'S RECOMMENDATION BUT NOT LESS THAN 1.5 LB/CU. YD. 2. PROVIDE 3000 PSI AT 28 DAYS MINIMUM FOR DURABILITY AT BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS, PORCHES, CARPORT SLABS AND STEPS EXPOSED TO THE WEATHER AND FOR ALL GARAGE FLOOR SLABS. CONCRETE SHALL BE AIR ENTRAINED CONFORMING TO ASTM C-260. TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL NOT BE LESS THAN 5% OR MORE THAN 7%. PLACE CONCRETE: PER ACI 304 AND CONFORM TO ACI 305 AND 306 FOR HOT AND COLD WEATHER PLACEMENT AND CURING PROTECTION. USE INTERIOR MECHANICAL VIBRATORS WITH 7000 RPM MINIMUM FREQUENCY. DO NOT OVER-VIBRATE. CONCRETE SHALL BE POURED MONOLITHICALLY BETWEEN CONSTRUCTION OR EXPANSION JOINTS. PROTECT ALL FRESHLY PLACED CONCRETE FROM PREMATURE DRYING, EXCESSIVE HOT OR COLD TEMPERATURE FOR SEVEN DAYS AFTER POURING. NON-SHRINK GROUT: GROUT SHALL CONFORM TO CRD-C621. F'c = 5000 PSI IN 28 DAYS. FILL OR PACK ENTIRE SPACE UNDER PLATES OR SHAPES. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION, INSTALLATION, AND CURING. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60. DETAIL, FABRICATE AND PLACE PER ACI 315 AND ACI 378. LAP SPLICES SHALL BE 48 BAR DIAMETERS UNLESS NOTED OTHERWISE. PROVIDE CORNER BARS AT ALL HORIZONTAL BARS IN FOOTINGS AND WALLS. WELDED WIRE REINFORCEMENT SHALL CONFORM TO A185. LAP ONE FULL MESH ON SIDES AND ENDS BUT NOT LESS THAN 8 INCHES. PLACE AT MID-DEPTH OF SLAB OR AS SHOWN. POST-INSTALLED ANCHORS: SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE STRUCTURAL ENGINEER PRIOR TO INSTALLING POST-INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST- IN-PLACE ANCHORS. CARE SHALL BE TAKEN IN PLACING POST-INSTALLED ANCHORS TO AVOID CONFLICTS WITH REBAR. INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. INSTALLER SHALL BE QUALIFIED AND TRAINED BY THE MANUFACTURER. HOLES SHALL BE HAMMER DRILLED ONLY (ROTARY DRILLED ONLY AT UNREINFORCED MASONRY - NO HAMMER TOOLS). MIN FLASH OR SLAG (PCY) 57 OR 67 57 OR 67 ITEM TYPE. CONNECTION GENERAL REQUIREMENTS: PROVIDE MINIMUM NAILING PER IBC TABLE 2304.10.1 OR MORE, AS OTHERWISE SHOWN. STAGGER ALL NAILING TO PREVENT SPLITTING OF WOOD MEMBERS. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESERVATIVE TREATED WITH THE EXCEPTION OF INTERIOR CONCRETE TOPPINGS ON WOOD FLOOR SYSTEMS. HOLES AND CUTS IN 3x OR 4x PLATES SHOULD BE TREATED WITH A 9% SOLUTION OF COPPER NAPHTHENATE. BOLT HOLES IN WOOD MEMBERS SHALL BE A MINIMUM OF 1/32" TO A MAXIMUM OF 1/16" LARGER THAN THE BOLT DIAMETER. PROVIDE CUT WASHERS WHERE BOLT HEADS, NUTS AND LAG SCREW HEADS BEAR ON WOOD. PROVIDE A MINIMUM 3"x3"x0.229" PLATE WASHER ON ALL ANCHOR BOLTS WHICH CONNECT MUD SILLS TO FOUNDATION. DO NOT NOTCH OR DRILL STRUCTURAL MEMBERS, EXCEPT AS ALLOWED BY IBC SECTIONS 2308.4.2.4, 2308.5.9, 2308.5.10 AND 2308.7.4 OR AS RESTRICTED BY PLANS OR DETAILS, OR AS APPROVED PRIOR TO INSTALLATION. REFER TO PRESERVATIVE TREATED WOOD REQUIREMENTS IN THESE GENERAL NOTES FOR GALVANIZING REQUIREMENTS FOR CONNECTORS AND FASTENERS. FASTENING SCHEDULE FOR WOOD STRUCTURAL MEMBERS (UNLESS NOTED OTHERWISE ON PLANS) FRAMING CONNECTORS: SHALL HAVE ICC APPROVAL AND BE MANUFACTURED BY SIMPSON STRONG-TIE COMPANY, SAN LEANDRO, CA., OR PRE-APPROVED EQUAL. PROVIDE MAXIMUM SIZE AND QUANTITY OF NAILS OR BOLTS PER MANUFACTURER, EXCEPT AS NOTED OTHERWISE. PROVIDE LEAD HOLES AS REQUIRED TO PREVENT SPLITTING OF WOOD MEMBERS. REFER TO PRESERVATIVE TREATED WOOD REQUIREMENTS IN THESE GENERAL NOTES FOR GALVANIZING REQUIREMENTS FOR CONNECTORS AND FASTENERS. LAG SCREWS: SHALL CONFORM TO ANSI/ASME STANDARD B18.2.1. LAG SCREWS SHALL BE OF A DIAMETER INDICATED ON DRAWINGS WITH A MINIMUM OF 8x DIA. EMBEDMENT IN SUPPORTING MEMBER UNLESS NOTED OTHERWISE. CLEARANCE HOLE FOR THE SHANK SHALL BE THE SAME DIAMETER AS THE SHANK AND THE SAME DEPTH OF PENETRATION AS THE UNTHREADED PORTION OF THE SHANK. THE LEAD HOLE FOR THE THREADED PORTION SHALL HAVE A DIAMETER EQUAL TO 60 TO 75 PERCENT OF THE SHANK DIAMETER AND A LENGTH EQUAL TO AT LEAST THE LENGTH OF THE THREADED PORTION. THE THREADED PORTION OF THE SCREW SHALL BE INSERTED IN ITS LEAD HOLE BY TURNING WITH A WRENCH. SOAP OR OTHER LUBRICANT SHALL BE USED ON THE SCREWS OR IN THE LEAD HOLE TO FACILITATE INSERTION AND PREVENT DAMAGE TO THE SCREW. LAG SCREWS SHALL NOT BE DRIVEN WITH A HAMMER. REFER TO PRESERVATIVE TREATED WOOD REQUIREMENTS IN THESE GENERAL NOTES FOR GALVANIZING REQUIREMENTS FOR CONNECTORS AND FASTENERS. METAL-PLATE-CONNECTED WOOD TRUSSES: SHALL BE MANUFACTURED AND INSTALLED WITHIN THE JURISDICTION REQUIREMENTS, AND DESIGNED AND DETAILED IN ACCORDANCE WITH ANSI/TP-1, INCLUDING BRACING AND WIND UPLIFT. PROVIDE 2x6 TOP CHORDS, AND 2x4 BOTTOM CHORDS AND WEBS, UNLESS COORDINATED AND APPROVED. TRUSSES SHALL BE DESIGNED TO CARRY THE LOADS LISTED IN THE DESIGN CRITERIA AND ANY ADDITIONAL LOADS INDICATED ON THE FRAMING PLANS AND DETAILS. TRUSSES INDICATED ON PLANS ARE FOR TYPICAL UNIFORMLY LOADED CONDITIONS. MANUFACTURER SHALL PROVIDE ADDITIONAL OR SPECIAL TRUSSES AS REQUIRED TO SUPPORT SPECIAL LOADING CONDITIONS AS INDICATED ON DRAWINGS. PROVIDE INSTALLATION FRAMING PLANS AND DRAWINGS. PROVIDE CERTIFICATE OF CONFORMANCE FROM AN INDEPENDENT TESTING LABORATORY OR A LICENSED PROFESSIONAL ENGINEER CERTIFYING THAT THEY HAVE INSPECTED THE FINISHED TRUSSES AND THAT ALL TRUSSES ARE CONSTRUCTED IN CONFORMANCE WITH THE TRUSS DESIGN DRAWINGS. I-JOISTS: SHALL BE APA EWS PERFORMANCE RATED I-JOISTS (PRI) OR PRE-APPROVED EQUAL. I-JOISTS SHALL BE MANUFACTURED IN CONFORMANCE WITH APA PRI-400 CONFORMING TO APPROVED SHOP AND INSTALLATION DRAWINGS. CEILING JOIST TO PARALLEL RAFTER CEILING JOIST: LAP OVER PARTITION BLOCKING TO RAFTER RIM BOARD TO RAFTER TOP PLATE TO TOP PLATE TOP PLATE AT INTERSECTIONS HEADER TO HEADER TOP OR BOTTOM PLATE TO STUD RAFTER OR TRUSS TO TOP PLATE CEILING JOIST TO TOP PLATE STUD TO SOLE PLATE BOTTOM PLATE TO FLOOR JOIST AT BRACED PANEL JOISTS TO TOP PLATE, SILL OR GIRDER BRIDGING TO JOIST BLOCKING TO JOISTS BLOCKING TO TOP PLATE RIM JOIST TO JOIST RIM JOIST TO SILL OR TOP PLATE CONTINUOUS HEADER TO STUD BUILT-CORNER STUDS BUILT-UP BEAMS (PER LAYER) RAFTERS TO RIDGE BOARD RAFTERS TO HIP FACE NAIL FACE NAIL FACE NAIL TOENAIL END NAIL FACE NAIL FACE NAIL FACE NAIL FACE NAIL FACE NAIL END NAIL TOE NAIL & END NAIL TOE NAIL TOE NAIL TOE NAIL TOE NAIL FACE NAIL CONNECTOR CONNECTOR FACE NAIL FACE NAIL TOENAIL & CONNECTOR TOENAIL COLLAR TIE TOP PLATE LAP STUD TO STUD TOE NAIL & FACE NAIL TOE NAIL & FACE NAIL TOE NAIL & FACE NAIL (3) 16d H2.5 @ 48" O.C. (3) 16d (3) 16d (3) 16d (3) 8d (3) 8d (2) 16d (2)16d @ 12" O.C. (4) 16d (8) 16d (2) 16d @ 24" O.C. 16d @ 16" O.C. EA. EDGE (2) 16d (4) 8d (2) 16d 16d @ 16" O.C. (3)16d @ 16" O.C. (4) 8d (2) 8d (3) 8d (3) 8d (3) 16d A35 @ 24" O.C. A35 16d @ 24" O.C. 16d @ 16" O.C. EA. EDGE (4) 16d (3) 16d (4) 16d (3) 16d CARPENTRY: PENNYWEIGHT DIAMETER (IN) 8d COMMON WIRE 8d "DIPPED GALV. BOX" 8d "SHINY BOX" 12 GA. STAPLES 14 GA. STAPLES 15 GA STAPLES 10d COMMON WIRE 10d "HOT DIPPED GALV. BOX" 10d "SHINY BOX" 0.131 0.131 0.113 0.1055 0.080 0.072 0.148 0.148 0.128 2-1/2 1-1/2* 1-1/2* 3 *BASED ON 15/32" PLYWOOD OR OSB. **REFERENCE TO COLOR CODED NAILS PER TRACKERS SYSTEM. MINIMUM DESIGN VALUES: 1. 2x LVL: Fb = 1700 PSI, Fv = 285 PSI, E = 1300 KSI 2. 1-3/4" LVL: Fb = 2600 PSI, Fv = 285 PSI, E = 1800 KSI 3. 3-1/2" LVL: Fb = 2900 PSI, Fv = 285 PSI, E = 2000 KSI 4. 5-1/4" LVL: Fb = 2900 PSI, Fv = 285 PSI, E = 2000 KSI 5. RIMBOARD:APA/EWS PERFORMANCE RATED RIM (PRR-401) 1-1/4" MINIMUM THICKNESS PRESERVATIVE TREATED WOOD REQUIREMENTS: TREATMENTS OTHER THAN THOSE LISTED BELOW ARE NOT PERMITTED. 6 6 4-1/2 6 6 5 6 6 4-1/2 4 4 3 5-1/2 4 3 4 4 3 3 3 2-1/2 4 3 2-1/2 3 3 2-1/4 BLUE - YELLOW - - - PURPLE - WHITE FOR DIAPHRAGM OR SHEAR WALL NAILING THE FOLLOWING FASTENER TYPES MAY BE USED AT EQUIVALENT SPACING TO THAT SPECIFIED ON PLANS: NAILS: CONNECTION DESIGNS ARE BASED ON "COMMON WIRE" NAILS WITH THE FOLLOWING PROPERTIES: WOOD SHEATHING (STRUCTURAL): SHEATHING SHALL BE PLYWOOD OR ORIENTED STRAND BOARD. PLYWOOD SHEATHING SHALL BE 5-PLY MINIMUM WHERE INDICATED AS 3/4" OR THICKER. WOOD SHEATHING SHALL BE "STRUCTURAL I" CONFORMING TO PS1-09 AND/OR PS2-10. ALL PANELS SHALL BEAR THE STAMP OF AN APPROVED GRADING AGENCY. SPAN RATING SHALL BE PROVIDED AS FOLLOWS: ROOF FRAMING AT 32"O.C. (48/24); ROOF FRAMING AT 24"O.C. (32/16); WALLS (32/16); FLOORS (48/24) ALL WOOD SHEATHED WALLS SHALL BE BLOCKED AT ALL PANEL EDGES UNLESS NOTED OTHERWISE. GLUE-LAMINATED MEMBERS: CONFORM TO ANSI/AITC A190.1. MEMBERS SHALL BE COMBINATION 24F-V4 DOUGLAS FIR (DF) FOR SIMPLE SPANS AND 24F-V8 DF FOR CANTILEVERED SPANS (Fb=2400 PSI, Fv=265 PSI, E= 1.8X10^6 PSI) AND DF COMBINATION 2 FOR COLUMNS. ARCHITECTURAL APPEARANCE GRADE WHERE EXPOSED TO VIEW; INDUSTRIAL APPEARANCE GRADE WHERE NOT EXPOSED TO VIEW. ALL MEMBER TO HAVE EXTERIOR GLUE AND HAVE AITC OR APA-EWS STAMP. CAMBER AS SHOWN ON STRUCTURAL DRAWINGS. FRAMING LUMBER: STANDARDS. EACH PIECE SHALL BEAR THE GRADE TRADEMARK OF THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB), WESTERN WOOD PRODUCTS ASSOCIATION (WWPA), OR OTHER AGENCY ACCREDITED BY THE AMERICAN LUMBER STANDARD COMMITTEE (ALSC) TO GRADE UNDER ALSC CERTIFIED GRADING RULES. SPECIES AND GRADE (BASE DESIGN VALUE) 1. 6x BEAMS AND HEADERS. "DOUG FIR-LARCH" NO. 1 (Fb=1350 PSI, Fv=170 PSI) 2. 2x TO 4x JOISTS, PURLINS AND HEADERS. "DOUG FIR-LARCH" NO. 2 (Fb=900 PSI, Fv=180 PSI) OR "HEM-FIR" NO. 1 (Fb=975 PSI, Fv=150 PSI) 3. 6x POSTS AND COLUMNS. "DOUG FIR-LARCH" NO. 1 (Fc=1000 PSI) 4. EXTERIOR STUDS, INTERIOR BEARING WALLS AND 4x COLUMNS. "DOUG FIR-LARCH" NO. 2 (Fb= 900 PSI, Fc= 1350 PSI) OR "HEM-FIR" NO. 1 (Fb=975 PSI, Fc=1350 PSI). 5. INTERIOR NON-BEARING STUD WALLS. "DOUG FIR-LARCH" NO. 2 (Fb=900 PSI. Fc=1350 PSI) OR "HEM-FIR" NO. 1 (Fb=975 PSI, Fc=1350 PSI) STRUCTURAL COMPOSITE LUMBER (SCL): SHALL BE MANUFACTURED BY WEYERHOUSER, OR PRE-APPROVED EQUAL IN ACCORDANCE WITH APPROVED SHOP AND INSTALLATION DRAWINGS CONFORMING TO A CURRENT ICC EVALUATION REPORT. LENGTH (IN)TRACKER** COLOR CODED NAILS 8d 10d 16d 20d .131 .148 .162 .192 2-1/2 3 3-1/2 4 BLUE PURPLE ORANGE ----- TRACKER** COLOR CODED NAILS 2-1/2 2-1/2 1-7/8* 3 3 EQUIVALENT SPACING (IN) LENGTH (IN)DIA. (IN)FASTENER TYPE SBX: DOT SODIUM BORATE FIR: DOUG-FIR OR HEM-FIR ACQ: ALKALINE COPPER QUAT SP: SOUTHERN PINE CBA & CA: COPPER AZOLE 2. CONNECTORS: JOIST HANGERS, STRAPS, FRAMING CONNECTORS, COLUMN CAPS AND BASES, ETC. FASTENERS: MACHINE BOLTS, ANCHOR BOLTS AND LAG SCREWS WITH ASSOCIATED PLATE WASHERS AND NUTS. NAILS, SPIKES, WOOD SCREWS, ETC. 3.G60, G90 & G185 PER ASTM A653 FOR COLD-FORMED STEEL CONNECTORS. BATCH/POST HOT-DIP GALVANIZED PER ASTM A123 FOR CONNECTORS. HOT-DIP GALVANIZED PER ASTM A153 FOR FASTENERS OR MECHANICALLY GALVANIZED FASTENERS PER ASTM B695, CLASS 55 OR GREATER. 1. CCA: CHROMATED COPPER ARSENATE NOT PERMITTED 2x, 4x, 6x (FIR), OR GLULAM (SP) 2x, & 4x (FIR) 2x, & 4x (CEDAR) SBX GALV (G60) ACQ, CBA, CA ACQ, CBA, CA NONE 6x (FIR), OR GLULAM (SP) 6x OR GLULAM (CEDAR) NONE GALV (G90) GALV (G185) GALV (G90) ACQ, CBA, CA GALV (G185) GALV (G185)EXPOSUREWETCONNECTORS & FASTENERS (2)(3) PRESERVATIVE TREATMENT (1) SPECIFIED MATERIAL FRAMING, DECKING BEAMS & COLUMNS FOUNDATION SILL PLATES, TOP PLATES & LEDGERS ON CONCRETE OR MASONRY WALLS (4)DRYAPPLICATION 04/02/2022DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF 16842 124th Ave SERenton, WA 98058253-222-1010Parcel # - 1432400030G Singh Investments LLCPrinted On: 1/22/2022 07:39:01 Sheet: Elevation Home Designs Job # : 21-0217Disclaimers:---These plans are exclusive property of Elevation Home Designs (EHD) and may not be sold to any personor business without expressed written consent of EHD. These plans are for one (1) time use only for EHD'scustomer - G Singh Investments LLC and to be built on the customer's site at 16842 124th Ave SE inRenton, WA 98058.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation Home Designs. Written permission must be obtained andgranted prior to any use and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizLayout Sheet # 8 of 15 Foundation Plan S1.1 CrawlAccess6'-3"30"6'-3"12'44'-6" 5'-6"56'-6" 62'36"12'18'-2 1/2"45'-11 1/2"15'15'GARAGE SLAB SLAB CRAWL SPACE CRAWL SPACE6mm Black Visqueen Vapor Barrier in Crawl Space Existing Crawl Existing Garage SlabExisting Slab Foundation Plan - EHD-1019481-S Proposed Scale: 1/4 in = 1 ft FOUNDATION SCHEDULE F-1: 2' 6" x 2' 6" x 10 W/ 4#4 BARS E.W F-2: 3' 0" x 3' 0" x 10 W/ 5#4 BARS E.W F1 F2F2 F1 drill and epoxy new footing and stemwall's longitudunal bars into existing concrete using simpson set-xp epoxy w/ 4" embeddment, typ FOUNDATION NOTES: 1. DO NOT SCALE DRAWINGS, REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 2. BOTTOM OF EXTERIOR FOOTINGS SHALL BE MINIMMUM 12" BELOW GRADE 3. 4" CONCRETE SLAB OVER 6MIL VAPOR BARRIER ON 6" PF GRAVEL OR CRUSHED ROCK OVER FIRM UNDISTURBED SOIL OR ENGINEERED COMPACTED BACK-FILL. REINFORCE WITH 6 x 6 W1.4 x W1.4 WWF 4. ALL WOOD IN CONTACT WITH CONCRETE SHOULD BE PRESSURE TREATED WOOD. 5. REFER TO GENERAL STRUCTURAL NOTES PAGE ON S0.0 FOR ADDITIONAL REQUIREMENTS. drill and epoxy new footing and stemwall's longitudunal bars into existing concrete using simpson set-xp epoxy w/ 4" embeddment, typ existing footing shall be min. 12" wide w/ 6" thick concrete stem wall, typ 04/02/2022DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF 16842 124th Ave SERenton, WA 98058253-222-1010Parcel # - 1432400030G Singh Investments LLCPrinted On: 1/22/2022 07:39:01 Sheet: Elevation Home Designs Job # : 21-0217Disclaimers:---These plans are exclusive property of Elevation Home Designs (EHD) and may not be sold to any personor business without expressed written consent of EHD. These plans are for one (1) time use only for EHD'scustomer - G Singh Investments LLC and to be built on the customer's site at 16842 124th Ave SE inRenton, WA 98058.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation Home Designs. Written permission must be obtained andgranted prior to any use and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizStandard Plumbing Drops Scale: No Scale ** These are Standard Plumbing Drop Locations. Check Plumbing Fixtures for Exact Locations. Dimensions on Joist Plan are Based off of these Standards.18"8"15"12" Layout Sheet # 9 of 15 1st Flr Joist Framing S1.24'-6"19"3'-1"12'-7"5'-9"14"19" 12" GARAGE SLAB SLAB CRAWL SPACE CRAWL SPACE6mm Black Visqueen Vapor Barrier in Crawl Space Existing Crawl Existing Garage SlabExisting Slab 9 1/2" I-Joist @ 16" oc Framing Label @ 16" oc Double Joist 1st Floor Joist Plan -EHD-1019481-S Proposed Scale: 1/4 in = 1 ft FLOOR FRAMING NOTES: 1. DO NOT SCALE DRAWINGS, REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 2. FLOOR SHEATHING SHALL BE 3/4" TONGUE AND GROOVE A.P.A. RATED PANELS. (EXPOSURE 1, SPAN RATING 48/24). GLUE AND NAIL SHEATHING AT ALL FRAMED PANEL EDGES WITH 10d AT 6" O.C. AND TO ALL INTERMEDIATE FRAMING AT 12" O.C 3. HEADERS OVER LOAD BEARING DOORS AND WINDOW OPENINGS SHALL BE MINIMUM 4x10 U.N.O. 4.PROVIDE (2) STUDS MINIMUM AT EACH END OF ALL BEAMS U.N.O. ON PLANS. BEAR BEAM FULLY ON BUILT UP COLUMN AND PROVIDE POSITIVE CONNECTION BY EITHER A35 OR LTP4 CLIPS ON EACH SIDE OF BEAM 5.REFER TO GENERAL STRUCTURAL NOTE PAGE ON S0.0 FOR ADDITIONAL REQUIREMENTS FLOOR BEAM SCHEDULE FB-1: (2) 1 3/4'' x 9 1/2'' 2.0 E MICROLAM LVL (SISTERED) HDR: 4x8 DF-L NO.2 (UP TO 4'); 4x10 DF-L NO.2 (UP TO 6'); 4x12 DF-L NO.2 (UP TO 8') 9 1/2" TJI 110 @16" O.C. 9 1/2" TJI 110 @16" O.C. 1 S4.1 1 S4.1 2 S4.1 2 S4.1 3 S4.1 FB-1 9 1/2" TJI 110 @16" O.C. 2 S4.1 drill and epoxy new footing and stemwall's longitudunal bars into existing concrete using simpson set-xp epoxy w/ 4" embeddment, typ Place 2x (flat) sleeper curbs at 36" o.c. (bolted to slab w/ 1/2" dia. titen-hd anchors at 48" o.c. Install 2x6 joists at 16" o.c. (perpendicular to curbs).04/02/2022DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF 16842 124th Ave SERenton, WA 98058253-222-1010Parcel # - 1432400030G Singh Investments LLCPrinted On: 1/22/2022 07:39:01 Sheet: Elevation Home Designs Job # : 21-0217Disclaimers:---These plans are exclusive property of Elevation Home Designs (EHD) and may not be sold to any personor business without expressed written consent of EHD. These plans are for one (1) time use only for EHD'scustomer - G Singh Investments LLC and to be built on the customer's site at 16842 124th Ave SE inRenton, WA 98058.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation Home Designs. Written permission must be obtained andgranted prior to any use and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizII II I Layout Sheet # 10 of 15 1st Floor Framing S2.1 Shower (ADA)TDWShower (ADA)T TShower (ADA)W01 5040 XO Egress (P)W02 5030 XO Egress (E)W03 5030 XO Egress (E) 9070 Garage OHD (E) D01 3068 D11 3068 50685068D14 3068D15 3068D16 3068 W04 5040 XO Egress (P)506860 Bypass5068E01 3068 (P) W05 5040 XO Egress (P)W06 5040 XO Egress (P)D03 3068D04 3068 D05 3068 D06 3068 50 Bypass W07 5040 XO Egress (P)W08 6040 XO (E) E02 3068 (E) E03 3068 (P) 50 Bypass D09 3068D10 3068 4x6 DF#2 3'-6"5'3'-6"28"5'4'-11 1/2"5' 12'5'-5 1/2"4'-1 1/2"4'-6"3'-3 1/2"12'-3 1/2" 27 1/2" 3'-4 1/2"5'4'-2" 5'-6"56'-6" 62'36"12'6'-1 1/2"3'-4"12'-6 1/2"36"34'3'-5 1/2"21"5'26 1/2"12'-8 1/2"27 1/2"8'-11 1/2"3'-5 1/2"11'-7"15'24'39'37'32"5'19" 13 1/2" 5'4'-4"9'-6 3/4"6'25"30"5'26 1/2" 9'-3" 27 1/2" 10'-5 1/2"17'-7 3/4"9'-8 1/2"12'-7 3/4" 22'40' 62' 4'-11"3'-10 1/2"10 1/2"4'-3 1/2"5'-8"5'-2"7'-10"8'-0 1/2"5'-4 1/2"3'-1 1/2"36"3'-3 1/2"14'-4 1/2"3'-7"17'-8"5'-2"12'-5 3/4" 4'6'-5"27 1/2"3'-5 1/4"5'-5 1/2"24" 22"3'-2"5'-9 1/2"5'-9"7'-11 1/2"3'-2"27 1/2"7'-9 1/2"CL 4'-3 1/2"1955 SQ FT 1st Floor Framing Plan - EHD-1019481-S Proposed Scale: 1/4 in = 1 ft LIVING AREA BEDROOM #3 (E) CLOSET #3 (E) BEDROOM #2 (E) CLOSET #2 (E) CLOSET #1 (E) BEDROOM #1 (E) HALLWAY (E) LIVING ROOM (E) BEDROOM #4 (P)BEDROOM #5 (P)BEDROOM #6 (P) BATH #2 (P) CLOSET #6 (P) CLOSET #5 (P)LAUNDRY (P)KITCHEN (E) BATH #3 (P) CLOSET #4 (P) 1 CAR GARAGE (E) CLOSET #7 (P) HALLWAY (P) BEDROOM #7 (E) BATH #1 (E)04/02/2022DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF 16842 124th Ave SERenton, WA 98058253-222-1010Parcel # - 1432400030G Singh Investments LLCPrinted On: 1/22/2022 07:39:01 Sheet: Elevation Home Designs Job # : 21-0217Disclaimers:---These plans are exclusive property of Elevation Home Designs (EHD) and may not be sold to any personor business without expressed written consent of EHD. These plans are for one (1) time use only for EHD'scustomer - G Singh Investments LLC and to be built on the customer's site at 16842 124th Ave SE inRenton, WA 98058.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation Home Designs. Written permission must be obtained andgranted prior to any use and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizII II I Layout Sheet # 11 of 15 1st Floor Shearwall S2.2 1955 SQ FT 1st Floor Shearwall Plan -EHD-1019481-S Proposed Scale: 1/4 in = 1 ft LIVING AREA BEDROOM #3 (E) CLOSET #3 (E) BEDROOM #2 (E) CLOSET #2 (E) CLOSET #1 (E) BEDROOM #1 (E) HALLWAY (E) LIVING ROOM (E) BEDROOM #4 (P)BEDROOM #5 (P)BEDROOM #6 (P) BATH #2 (P) CLOSET #6 (P) CLOSET #5 (P) LAUNDRY (P) KITCHEN (E) BATH #3 (P) CLOSET #4 (P) 1 CAR GARAGE (E) CLOSET #7 (P) HALLWAY (P) BEDROOM #7 (E) BATH #1 (E) SWXX REFER TO SHEARWALL SCHEDULE ON PAGE S4.3 SW1 ALL EXTERIOR WALLS SHALL BE SW1 UNLESS NOTED OTHERWISE HOLDOWN LEGEND 1. HDU2 HOLDOWN W/SSTB20 ANCHOR OR STHD 14 1 1 1 CONT. CS14 STRAP AT OVER AND UNDER OPENING REFER TO DETAIL 5/S4.3 1 1 04/02/2022DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF 16842 124th Ave SERenton, WA 98058253-222-1010Parcel # - 1432400030G Singh Investments LLCPrinted On: 1/22/2022 07:39:02 Sheet: Elevation Home Designs Job # : 21-0217Disclaimers:---These plans are exclusive property of Elevation Home Designs (EHD) and may not be sold to any personor business without expressed written consent of EHD. These plans are for one (1) time use only for EHD'scustomer - G Singh Investments LLC and to be built on the customer's site at 16842 124th Ave SE inRenton, WA 98058.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation Home Designs. Written permission must be obtained andgranted prior to any use and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.biz0102 03 04 05 06 *Roof Overhangs are 16 Eaves & 12" Gables UNO *Downspouts Locations are Approximate Roof Area Plan - EHD-1019481-S Proposed Scale: NTS Projected Area - Surface Area - Framing Area - Overhang Area - This is the area of the roof plane polyline, including fascia and shadow boards, as seen in floor plan view. It does not equal the Roof Surface Area unless the pitch is 0. This is the area of the roof plane's top surface, which covers the fascia and shadow boards with the pitch taken into account. This is the area of the roof plane's framing, not including the fascia or shadow boards, with the pitch taken into account. It is slightly smaller than the Roof Surface Area as roofing typically overhangs the framing by a small amount. This is the area of the roof plane's overhang, including fascia and shadow boards, as seen in floor plan view. Roof Plane Schedule Roof ID Pitch Floor Framing Area Surface Area Projected Area Overhang Area 01 5 : 12 1 138.05 139.14 128.43 23.68 02 5 : 12 1 138.02 139.14 128.43 16.52 03 5 : 12 1 1131.52 1137.34 1049.85 104.18 04 5 : 12 1 1039.34 1044.2 963.87 79.9 05 5 : 12 1 49.38 50.08 46.23 10.45 06 5 : 12 1 49.4 50.08 46.23 10.62 Totals:2545.71 2559.98 2363.04 245.35 Layout Sheet # 12 of 15 Roof Framing S3.1 12"16"Over-Framing Roof Framing Plan - EHD-1019481-S Proposed Scale: 1/4 in = 1 ft Vaulted AreaOver-Framing Continuous Ridge Vent 30W x 24D x 30H Attic Access Pre-MFR Trusses @ 24"oc Girder Truss Girder Truss * Roof Overhangs are 16" Eaves & 12" Gables UNOHDR HDR HDR HDR HDRHDR1 S4.2 3 S4.2 SIMPSON LGT GIRDER TIE DOWN REQUIRED AT EA END TYP SIMPSON LGT GIRDER TIE DOWN REQUIRED AT EA END TYP 2 S4.2 3 S4.2 4 S4.2 1 S4.2 5 S4.2 HDR 6x12 HDR1 S4.2 HDRHDR HDR ROOF FRAMING NOTES: 1. DO NOT SCALE DRAWINGS, REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 2. PRE-MANUFACTURED ROOF TRUSS DESIGN IS TO BE PROVIDED BY MANUFACTURER. SEE STRUCTURAL NOTES ON S0.0 FOR REQUIREMENTS. 3. ROOF SHEATHING SHALL BE 7/16" A.P.A. RATED PANELS. (EXPOSURE 1, SPAN RATING 32/16). NAIL SHEATHING AT ALL FRAMED PANEL EDGES WITH 8d AT 6" O.C. AND TO ALL INTERMEDIATE FRAMING AT 12" O.C. NAILS SHALL BE LOCATED AT LEAST 3/8" FROM THE EDGES OF PANELS. 4. HEADERS OVER LOAD BEARING DOORS AND WINDOW OPENINGS SHALL BE MINIMUM 4x10 U.N.O. 5. PROVIDE (2) STUDS MINIMUM AT EACH END OF ALL BEAMS U.N.O. ON PLANS. BEAR BEAM FULLY ON BUILT UP COLUMN AND PROVIDE POSITIVE CONNECTION BY EITHER A35 OR LTP4 CLIPS ON EACH SIDE OF BEAM 6. REFER TO GENERAL STRUCTURAL NOTE PAGE ON S0.0 FOR ADDITIONAL REQUIREMENTS 7. PANELS SHALL NOT BE LESS THAN 4' X 8' EXCEPT AT BOUNDARIES AND CHANGES IN FRAMING WHERE MINIMUM PANEL DIMENSION SHALL BE 24".04/02/2022DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF 16842 124th Ave SERenton, WA 98058253-222-1010Parcel # - 1432400030G Singh Investments LLCPrinted On: 1/22/2022 07:39:02 Sheet: Elevation Home Designs Job # : 21-0217Disclaimers:---These plans are exclusive property of Elevation Home Designs (EHD) and may not be sold to any personor business without expressed written consent of EHD. These plans are for one (1) time use only for EHD'scustomer - G Singh Investments LLC and to be built on the customer's site at 16842 124th Ave SE inRenton, WA 98058.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation Home Designs. Written permission must be obtained andgranted prior to any use and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizLayout Sheet # 13 of 15 Structural Details S4.1 04/02/2022DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF 16842 124th Ave SERenton, WA 98058253-222-1010Parcel # - 1432400030G Singh Investments LLCPrinted On: 1/22/2022 07:39:02 Sheet: Elevation Home Designs Job # : 21-0217Disclaimers:---These plans are exclusive property of Elevation Home Designs (EHD) and may not be sold to any personor business without expressed written consent of EHD. These plans are for one (1) time use only for EHD'scustomer - G Singh Investments LLC and to be built on the customer's site at 16842 124th Ave SE inRenton, WA 98058.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation Home Designs. Written permission must be obtained andgranted prior to any use and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizLayout Sheet # 14 of 15 Structural Details S4.2 04/02/2022DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF 16842 124th Ave SERenton, WA 98058253-222-1010Parcel # - 1432400030G Singh Investments LLCPrinted On: 1/22/2022 07:39:02 Sheet: Elevation Home Designs Job # : 21-0217Disclaimers:---These plans are exclusive property of Elevation Home Designs (EHD) and may not be sold to any personor business without expressed written consent of EHD. These plans are for one (1) time use only for EHD'scustomer - G Singh Investments LLC and to be built on the customer's site at 16842 124th Ave SE inRenton, WA 98058.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation Home Designs. Written permission must be obtained andgranted prior to any use and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizLayout Sheet # 15 of 15 Structural Details S4.3 04/02/2022DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF