HomeMy WebLinkAboutEX2_P_G_Singh_Addition_Site_Plan_Drainage_Control_20220405_v272'105'72'105'NE / LE / L
H / W
S
G
PCPC
PCPC Surface Water Flow25'7'-6"20'56'-6"8'-8"12'22'20'-8"7'-6"25'
1955 SQ FT
Site Plan - EHD-1019481-S Proposed
Scale: 1" = 20'-0"
LIVING AREA
BEDROOM #3 (E)
CLOSET #3 (E)
BEDROOM #2 (E)
CLOSET #2 (E)CLOSET #1 (E)
BEDROOM #1 (E)
HALLWAY (E)
LIVING ROOM (E)
BEDROOM #4 (P)
BEDROOM #5 (P)
BEDROOM #6 (P)
BATH #2 (P)
CLOSET #6 (P)
CLOSET #5 (P)
LAUNDRY (P)
KITCHEN (E)
BATH #3 (P)400'124th Ave SESetback LineExisting Driveway
Existing
Garage
Existing 1st Floor Proposed
1st FloorExisting
Sidewalk
CLOSET #4 (P)
1 CAR GARAGE (E)
CLOSET #7 (P)
HALLWAY (P)
BEDROOM #7 (E)
BATH #1 (E)
Construction
Entrance
Clearing Limits
402'Silt Fence
**All exposed area to be topsoiled, seeded, &
mulched by the owner at the completion of the
construction or if left unworked for 7 days
during summer months and 2 days for winter.
Existing Driveway
Max Grade 5%
Note
1.These are minimum requirements. Adjust
erosion control practices and maintain as
conditions require.
2.Erosion and sediment control shall be in
place before initiating any construction
activities. An inspection must be made after
installation of erosion control practices.
Silt Fence
**Disturbed area
2,240 Sq.Ft
Mulch/Seed
Topsoil Stockpile
To be covered w/ Plastic
16842 124th Ave SERenton, WA 98058253-222-1010Parcel # - 1432400030G Singh Investments LLCPrinted On:
4/4/2022 08:23:12
Sheet:
Elevation Home Designs
Job # : 21-0217Disclaimers:---These plans are exclusive property of Elevation Home Designs (EHD) and may not be sold to any personor business without expressed written consent of EHD. These plans are for one (1) time use only for EHD'scustomer - G Singh Investments LLC and to be built on the customer's site at 16842 124th Ave SE inRenton, WA 98058.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architecturalwork" under sec. 102 of the copyright act, 17 USC as amended December 1990. The protection includes butis not limited to the overall form as well as the arrangement and composition of spaces and elements ofdesign. Under such protection, any unauthorized use of these plans, the design in whole or part, can legallyresult in monetary compensation to Elevation Home Designs. Written permission must be obtained andgranted prior to any use and/or design changes to these plans.253.533.0835es@structuralworks.net2102 E Main #105 Puyallup, WA 98372PH: 866.657.4371 | elevation.bizH/W
S
G
E/L
= Water Line
= Sewer / Septic
= Gas / Propane
= Electrical
Proposed Structures
Existing Structures
Driveway/Sidewalk
Legend - Additions/Remodels
-------------------------------------------------
SITE ANALYSIS
PROPERTY
Property Area =
Setback Area =
Easement Area =
Wetland Area =
Wetland Buffer Area =
Buildable Area =
-------------------------------------------------------------
HABITABLE
- Existing 1st Floor =
Total Existing =
- Proposed 1st Floor =
Total Proposed =
Total Habitable =
-------------------------------------------------------------
IMPERMEABLE & PERMEABLE
- Existing 1st Floor =
- Existing Driveway =
- Existing Garage =
Total Existing =
- Proposed 1st Floor =
- Proposed Overhang =
Total Proposed =
Total Impermeable =
Permeable Area =
Total Impermeable / Property Area
-------------------------------------------------------------
LOT COVERAGE (Structures over 42" High)
- Existing 1st Floor =
- Existing Garage =
Total Existing =
- Proposed 1st Floor =
Total Proposed =
Total Coverage =
Total Coverage / Property Area
-------------------------------------------------------------
FAR (Floor Area Ratio) Calculations
- Existing 1st Floor =
- Existing Garage =
Total Existing =
- Proposed 1st Floor =
Total Proposed =
Total Coverage =
Total Coverage / Property Area
7560 Sq.Ft.
- 4425 Sq.Ft.
- 0 Sq.Ft.
- 0 Sq.Ft.
- 0 Sq.Ft.
3135 Sq.Ft.
1146 Sq.Ft.
1146 Sq.Ft.
806 Sq.Ft.
806 Sq.Ft.
1952 Sq.Ft.
1146 Sq.Ft.
154 Sq.Ft.
167 Sq.Ft.
1467 Sq.Ft.
806 Sq.Ft.
241 Sq.Ft.
1047 Sq.Ft.
2514 Sq.Ft.
5046 Sq.Ft.
(2514 / 7560) = 33.25%
1146 Sq.Ft.
167 Sq.Ft.
1313 Sq.Ft.
806 Sq.Ft.
806 Sq.Ft.
2119 Sq.Ft.
(2119 / 7560) = 28.03%
1146 Sq.Ft.
167 Sq.Ft.
1313 Sq.Ft.
806 Sq.Ft.
806 Sq.Ft.
2119 Sq.Ft.
(2119 / 7560) = 28.03%
CASCADE VISTA ADD LESS C & M RGTS
PLat Block: 1
Plat Lot: 6
** This is not a survey. All Property Lines, Corners and Dimensions, as shown, are from information supplied by the
homeowner or county web sites. No Liability is assumed for variances ascertained by actual or more recent surveys.
Layout Sheet #
1 of 1
Site Plan
A0.1
Legal Description
RECEIVED
PLANNING DIVISION
06/29/2022
AVanGordon
additional erosion control
features may be required by city
of renton inspector
RECEIVED
04/05/2022 lwalker
BUILDING DIVISION PR22000117
B22001729
DocuSign Envelope ID: 7C583EF6-9816-4299-8D15-0EFD4D5E3DAF