Loading...
HomeMy WebLinkAboutzR-4215SetCW G O 2 z O I— z U-1 75 n O LU > W LU J C/) Q U T CASTLE DEVELOPMENT TOWNHOMES RECORD DRAWINGS w z a m . °. �w ° z w. . d . �' . J . . . . . . . . m <. . . . . . . . :,.• . Q . . . . . . . . . . . . . w .. :. . ,. ....... .... I........ .... 8' . . . . . . I. . CANTER STRIP 8' . . . . . . . . . . . . . . . . . . t',... ,, ". SIDEWALK . 4: ,PERMEABLE ` � CB. 1.0. '•� PAVEMEIyt ;.. .. . RIM EL. :. W,4LKWA.Y •' . 25..64.. IE=23..74'. . . . . . ....:. 4.50' ROW ci- CL . . . IE=23.74.' ,. DEDICATION . . . . ....� . . . . . . . . . . . . . aoo ..::::. F M SDMH #1. , o :::..1• .•: . TYPE 2 RIM EL, � Q . . Z :..'.' ' : �• .:.• : ':' • ' . 4: ,PERMEABLLE . 26.51 '. •,. .PAVEMENT IE=16.51.' I :.. :.. WALK1!AY • •, . I I . . . 4 wALKw,a.Y ......: a° I ° d ° AS -BUILT NOTE: LOCATIONS AND DIMENSIONS OF AS —BUILT STRUCTURES AND UTILITIES HAVE BEEN OBTAINED FROM FIELD MEASUREMENTS AND OBSERVATIONS PROVIDED FROM THE CONTRACTOR AND NOT BY SURVEY. HW s�I�Ajlj IL n co m pass ��� �z N ENGINEERING & SURVEYING N Western Washington Division dp 38375 �cy� w 165 NE Juniper Street, Suite 201 - IssaQuah, WA 98027 - Phone: (425) 392-0250 isTER� zEastern Washington Division SIONAL w 407 Swiftwater Blvd. ■ Cle Elum, WA 98922 ■ Phone: (509) 674-7433 SW 1/4 OF SE 1/4 OF SECTION 18, T. 23 N., R. 05 E., W.M. CITY OF RENTON, STATE OF WASHINGTON 7PN: 784130-0395 UNI T C BUILDING FOUNDATION J (TYP) COVERED PATIO COVERED PATIO RAISED J FLOWER BED ( COVEREDA710 BSBL TIP) UNIT B COVERED PA1T0 7PN: 784130-0400 COVERED PATIO UNIT A 0912012023 N 0 . COVERED PA710 PERMEABLE PAVER PATIO S 88'45'53" E 120.02' TPN: 784130-0410 ABBREVIATIONS APPROX APPROXIMATE/APPROXIMATELY BSBL BUILDING SET BACK LINE CB CATCH BASIN COR CITY OF RENTON E EAST EG EXISTING GRADE ETC ETCETERA EX EXISTING FFE FINISHED FLOOR ELEVATION FG FINISHED GRADE HMA HOT MIX ASPHALT IE INVERT ELEVATION MIN MINIMUM MAX MAXIMUM N NORTH ROW RIGHT OF WAY S SOUTH SO STORM DRAIN SOCO STORM DRAIN CLEANOUT SF SQUARE FEET/FOOT STD STANDARD TESC TEMPORARY EROSION AND SEDIMENT CONTROL TYP TYPICAL W WEST REVISION J UNIT B GARAGE 1s:oo'.. I'. -PRA WAY :...:. o o 00 LO ... 00 N . . 24.58' o fN A N DISCREPANCIES: O CO 0 5 10 SCALE 1 " = 10' TAX PARCEL: 784130-0400 HORIZONTAL DATUM: NAD 83189 BASIS OF BEARINGS: BASIS IS CALC'D N 88'4553" INALONG CENTERLINE OF S. 67H ST. VERTICAL DATUM: NA VD 88 BENCHMARK: 'L-1JL_1LJLJZJL I n[]Tm[ rLn LU [EM. LE PROJECT SITE0 LU TTO U � � 5 D Q S 7TH ST ORIGINAL BM: BENCH MARK NO. 2526 2" DOMED BRASS CAP AT INTX OF BACK OF CONC. SIDEWALK IN SW QUAD. INTX OF RAINIER AVE S. & 52ND AVE S ELEV. = 46.059 FEET 0 o TBM — A: SET HUB & MAG. NAIL ELEV. = 2ZO7 FEET TBM — B: SET HUB & MAG. NAIL ELEV. = 2Z 11 FEET INSTRUMENTATION: IF THERE ARE ANY DISCREPANCIES BETWEEN DIMENSIONS IN DRAWINGS AND EXISTING CONDITIONS WHICH WILL AFFECT THE WORK, THE CONTRACTOR SHALL BRING SUCH DISCREPANCIES TO THE ATTENTION OF THE ENGINEER FOR ADJUSTMENT BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER FITTING OF ALL WORK AND FOR THE COORDINATION OF ALL TRADES, SUBCONTRACTORS, AND PERSONS ENGAGED UPON THIS CONTRACT. EXISTING UTILITY NOTE: ALL LOCATIONS OF EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. CONTRACTOR RESPONSIBILITY: CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS, INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY, DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, AND THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. SURVEYED: BUI DESIGNED: IWD DRAWN: TN F CHECKED: IWD BY DATE APPR APPROVED: CID SCALE: 1 10, ONE ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M FIELD SURVEY CONDUCTED USING A COMBINATION OF GPS USING A REFERENCE NETWORK AND A 5" ELECTRONIC TOTAL STATION WAS USED FOR THIS FIELD TRAVERSE SURVEY. SURVEY PROCEDURES MEET OR EXCEED STATE STANDARDS AS SPECIFIED BY W.A.C. 332-130 WITH REGARD TO LINEAR AND ANGULAR CLOSURES. ALL MEASURING INSTRUMENTS FOR THIS SURVEY HAVE BEEN MAINTAINED ACCORDING TO MANUFACTURES SPECIFICATIONS AND HAVE BEEN COMPARED WITH A NATIONAL GEODETIC SURVEY CALIBRATED BASELINE WITHIN THE LAST 12 MONTHS. LEGAL DESCRIPTION: LOTS 5 AND 6, BLOCK 5, SM17HERS FIFTH ADDITION TO THE TOWN OF RENTON, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 16 OF PLATS, PAGE 33, RECORDS OF KING COUNTY, WASHINGTON. BSBL DISTANCES: QFRONT YARD: 10' QREAR YARD: 10' QSIDE YARD: 4' IMPERVIOUS AREA SUMMARY: WALKWAY = 1,064 SF ROOF TOP =4,313 SF DRIVEWAY = 594 SF TOTAL ON —SITE IMPERVIOUS =5,971 SF TOTAL SITE AREA=9,602 SF SITE IMPERVIOUS (%)=62.2% Know what's below. call before you dig. CITY OF RENTON Planning/Building/Public Works Dept. VICINITY MAP 1 "-1000' PROJECT TEAM: OWNER/APPLICANT ENGINEER: SURVEYOR: GE07ECHNICAL ENGINEER: YVONNE BUI CASTLE DEVELOPMENT, LLC 62010 1297H PL SE BELLEVUE, WA 98006 (206) 280-2272 COSTA PHILIPPIDES, PE ENCOMPASS ENGINEERING & SURVEYING 165 N.E. JUNIPER STREET, SUITE 201 ISSAQUAH, WA 98027 (425) 392-0250 TIMOTHY A. GRIFFIN, PLS TYEE SURVEYORS 17544 MIDVALE AVE N SUITE 107 SHORELINE, WA 98133 (206) 525-3660 BERNARD P. KNOLL, PE AGES ENGINEERING PO BOX 935 PUYALLUP, WA 98371 (253) 845-7000 SITE ADDRESS: UNIT A: 538 SHATTUCK AVE S UNIT B. 534 SHATTUCK AVE S UNIT C. 530 SHATTUCK AVE S RENTON, WA 98057 SITE AREA: 9,602 SF (0.220 ACRES) ZONING: R-14 UTILITY INFORMATION: SEWER/WATER. CITY OF RENTON (425) 430-6852 ELECTRIC/GAS: PSE 1-888-225-5773 FIRE DISTRICT: RENTON REGIONAL FIRE AUTHORITY (425) 430-7000 SHEET INDEX SHEET SHEET TITLE 1 AS -BUILT COVER SHEET 2 AS -BUILT TESC DEMOLITION AND TREE RETENTION PLAN 3 AS -BUILT TESC DETAILS 4 AS -BUILT PRELIMINARY GRADING AND DRAINAGE PLAN 5 AS -BUILT OVERALL UTILITY PLAN 6 AS -BUILT CONSTRUCTION DETAILS 7 AS -BUILT CONSTRUCTION DETAILS DWG# R-421501 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CASTLE DEVELOPMENT TOWNHOMES AS -BUILT COVER SHEET DATE: 09/29/20 FIELDBOOK: PAGE: SHEET: OF: 1 7 W U C/) U-1 G O z O z U-1 G n O J W > LU J I— U) a U L0 N 1 0 1 0 III LU 2 O z O z LU 2 n O LU > W 0 LU U) Q U m Lij Q z J TREE PROTECTION MEASURES DURING CONSTRUCTION: 1-'KUILC;IIUN MLAJUKLJ IN IHIS JULQSLUIIUN JHALL AI-'F'LT hUK ALL IKLLJ IHAI AKL TO BE RETAINED ON SITE AND OFF SITE. OFF -SITE TREES CONTAINING DRIP LINES THAT ENCROACH ONTO THE SITE UNDER CONSTRUCTION SHALL BE CONSIDERED PROTECTED TREES UNLESS IT IS DETERMINED THE ABUTTING PROPERTY OWNER IS IN COMPLIANCE WITH SUBSECTION C OF THIS SECTION, ALLOWED TREE REMOVAL ACTIVITIES. ALL OF THE FOLLOWING TREE PROTECTION MEASURES SHALL APPLY: A. CONSTRUCTION STORAGE PROHIBITED: THE APPLICANT MAY NOT FILL, EXCAVATE, STACK OR STORE ANY EQUIPMENT, DISPOSE OF ANY MATERIALS, SUPPLIES OR FLUIDS, OPERATE ANY EQUIPMENT, INSTALL IMPERVIOUS SURFACES, OR COMPACT THE EARTH IN ANY WAY WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO BE RETAINED. B. FENCED PROTECTION AREA REQUIRED: PRIOR TO DEVELOPMENT ACTIVITIES, THE APPLICANT SHALL ERECT AND MAINTAIN SIX-FOOT (6) HIGH CHAIN LINK TEMPORARY CONSTRUCTION FENCING AROUND THE DRIP LINES OF ALL RETAINED TREES OR AT A DISTANCE SURROUNDING THE TREE EQUAL TO ONE AND ONE -QUARTER FEET (1-1/4) FOR EVERY ONE INCH (1) OF TRUNK CALIPER, WHICHEVER IS GREATER, OR ALONG THE PERIMETER OF A TREE PROTECTION TRACT. PLACARDS SHALL BE PLACED ON FENCING EVERY FIFTY FEET (50) INDICATING THE WORDS, 'NO TRESPASSING -PROTECTED TREES, "OR ON EACH SIDE OF THE FENCING IF LESS THAN FIFTY FEET (50). SITE ACCESS TO INDIVIDUALLY PROTECTED TREES OR GROUPS OF TREES SHALL BE FENCED AND SIGNED. INDIVIDUAL TREES SHALL BE FENCED ON FOUR (4) SIDES. IN ADDITION, THE APPLICANT SHALL PROVIDE SUPERVISION WHENEVER EQUIPMENT OR TRUCKS ARE MOVING NEAR TREES. C. PROTECTION FROM GRADE CHANGES: IF THE GRADE LEVEL ADJOINING TO A TREE TO BE RETAINED IS TO BE RAISED, THE APPLICANT SHALL CONSTRUCT A DRY ROCK WALL OR ROCK WELL AROUND THE TREE. THE DIAMETER OF THIS WALL OR WELL MUST BE EQUAL TO THE TREES DRIP LINE. D. IMPERVIOUS SURFACES PROHIBITED WITHIN THE DRIP LINE: THE APPLICANT MAY NOT INSTALL IMPERVIOUS SURFACE MATERIAL WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO BE RETAINED, UNLESS OTHERWISE APPROVED BY THE CITY. (ORD. 5958, 12-9-2019) E. RESTRICTIONS ON GRADING WITHIN THE DRIP LINES OF RETAINED TREES: THE GRADE LEVEL AROUND ANY TREE TO BE RETAINED MAY NOT BE LOWERED WITHIN THE GREATER OF THE FOLLOWING AREAS: (1) THE AREA DEFINED BY THE DRIP LINE OF THE TREE, OR (II) AN AREA AROUND THE TREE EQUAL TO ONE AND ONE-HALF FEET (1-1/2) IN DIAMETER FOR EACH ONE INCH (1) OF TREE CALIPER. A LARGER TREE PROTECTION ZONE BASED ON TREE SIZE, SPECIES, SOIL, OR OTHER CONDITIONS MAY BE REQUIRED. (ORD. 5676, 12-3-2012) F. MULCH LAYER REQUIRED: ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE COVERED COMPLETELY AND EVENLY WITH A MINIMUM OF THREE INCHES (3) OF BARK MULCH PRIOR TO INSTALLATION OF THE PROTECTIVE FENCING. EXCEPTIONS MAY BE APPROVED IF THE MULCH WILL ADVERSELY AFFECT PROTECTED GROUND COVER PLANTS. (ORD. 5676, 12-3-2012) G. MONITORING REQUIRED DURING CONSTRUCTION: THE APPLICANT SHALL RETAIN A CERTIFIED ARBORIST OR LICENSED LANDSCAPE ARCHITECT TO ENSURE TREES ARE PROTECTED FROM DEVELOPMENT ACTIVITIES AND/OR TO PRUNE BRANCHES AND ROOTS, FERTILIZE, AND WATER AS APPROPRIATE FOR ANY TREES AND GROUND COVER THAT ARE TO BE RETAINED. H. ALTERNATIVE PROTECTION: ALTERNATIVE SAFEGUARDS MAY BE USED IF DETERMINED TO PROVIDE EQUAL OR GREATER TREE PROTECTION. EncomDass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 ■ IssaQuah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. ■ Cle Elum, WA 98922 ■ Phone: (509) 674-7433 CASTLE DEVELOPMENT TOWNHOMES RECORD DRAWINGS SW 114 OF SE 114 OF SECTION 18, T. 23 N., R. 05 E., W.M. CITY OF RENTON, STATE OF WASHINGTON I i z 0 5 10 a SCALE 1 " = 10' a ° 4 a" SILT FENCE PER COR d• ' a STD PLAN 214.00 (TYP) °• a : e e ° 47 x —X—X z °• CLFNC xX�x X MINIMIZE �BFNC x — ° d GRADINGICOMPAC77ON e ° X IN INFILTRA71ON AREA �' d e — — e. Q 4 d Z ad e: A. a •,° . 4 c d SS ° ' a..° d d d '.. e ° x LA REMOVE ALL ONSITE CONC a °. ° ° ' e aa NEXISTING 8" WATER PADS, F0077NG DRAINS, °4. 0ELECTRICAL SERVICES, AND - MAIN TO BE ° I ° d x ABANDONED AND OR" ° SEWER SERVICES (TIP OF 2) STABILIZED CONSIRUC71e ENTRANCE STOCK PILE REMOVED EASTa OF. a a:° d .. I PER COR STD PLAN 215.10a.. ° AREA THE R�WSED FIRE d q HYDRANT SERWCF� -°° ° d . I d LOCAON ° . ° I I e • d e d: IBC '° .a.• a d. ° a ° °• ° 4 °: °' - ° ° PROVIDE INLET PR07EC71ON TO ° x . . . . . . ALL ONSITE CATCH BASINS d a -- UN71L REMOVED (11P OF 2) ❑ 12" Di - - - _-_- x REMOVE EX °. SIDEWALK o 0 0 0 0 0 0 0 0 o 0 o CO . E 2 Q Q • �.° „GAT VALVE o 0 0 0 0 0 0 0 0 ° ER A -BUILT RAWINGS ° W W cn . . x ° • Wd W a a ° REMOVE FH ° J EX FDC � d EX FIRE DDCVA c °,. .°• ° � ° � � 4' •a a ° HYDRANT TO BE ° a 4 e e .... , ". e ° e .a ; • a . REMOVED a d. EXISTING 314 METERS 41D d . ° ° e x e ° ' SERVICES CUT AND CAPPED AT °. a. d a e a °.. a °. d MAIN LINE BY CITY FORCES e a d a' . a `d d e WATER METER PERMIT REQUIRED ° CONTRACTOR TO INVESTIGATE ° a TYPICAL FOR ALL d a°. AND REMOVE/REPLACE EXISTING ° and $ ° °". d °'• . e :: 4 ELECTRIC JUNC77ON BOX ° ° ° °d a °. d a d SS . d. °' REMOVE PARAMETER CHAIN x cn CLFNC LIPK FENCING (TYP) ---- x- x BFNC ae �— � �� T' d° a. A: .cn PROPERTY LINE (TYP) GING PROPERTY LINE TO THESOUTH TO BE REMOVED I 0912012023 I N O . REVISION SURVEYED: BUI DESIGNED: IWD DRAWN: TNF CHECKED: IWD BY DATE APPR APPROVED: CP SCALE: VERTICAL: NAVD 1988 1 "=10 , HORIZONTAL: NAD 1983/1991 ONE INCH DATU M AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY EX 8" SANITARY SEWER CUT/CAP EXISTING SIDE SEWER AT PROPERTY LINE (TIP.) Know what's below. Call before you dig. •ff=,%CITY OF RENTON %OF Planning/Building/Public Works Dept EROSION PROTECTION NOTE: ALL EXPOSED SOIL AND/OR DISTURBED SURFACES TO BE COVERED WITH MULCH, STRAW, AND/OR PLASTIC SHEETING PER FIG. C.3.4.A AND/OR TABLE C.3.2.A CORSWDM. UNDER NO CIRCUMSTANCES SHALL SOIL STOCKPILES BE LEFT UNCOVERED. ARBORIST NOTE: ARBORIST TO BE ON -SITE TO SUPERVISE ALL CONSTRUCTION ACTIVITIES BENEATH THE DRIPLINES OF OFF -SITE TREES. CONSTRUCTION SEQUENCE: 1. PRE -CONSTRUCTION MEETING. 2. POST NOTICE OF CONSTRUCTION ACTIVITY SIGN WITH NAME AND PHONE NUMBER OF ESC SUPERVISOR. 3. FLAG OR FENCE CLEARING LIMITS. 4. INSTALL CATCH BASIN PROTECTION IF REQUIRED. 5. GRADE AND INSTALL CONSTRUCTION ENTRANCE(S). 6. INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.). 7. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH CITY OF RENTON EROSION AND SEDIMENT CONTROL STANDARDS. 8. RELOCATE SURFACE WATER CONTROLS AND EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE, THE EROSION AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY OF RENTON EROSION AND SEDIMENT CONTROL STANDARDS. 9. COVER ALL AREAS THAT WILL BE UNWORKED FOR MORE THAN SEVEN DAYS DURING THE DRY SEASON OR TWO DAY DURING WET SEASON WITH STRAW, WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING, OR EQUIVALENT. 10. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN 7 DAYS. 11. SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS. UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BE STABILIZED AND BEST MANAGEMENT PRACTICES REMOVED IF APPROPRIATE. 12. UPON COMPLETION OF THE PROJECT. ALL DISTURBED AREAS MUST BE STABILIZED AND BMP'S REMOVED, IF APPROPRIATE. R-421502 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CASTLE DEVELOPMENT TOWNHOMES AS -BUILT TESC DEMOLITION AND TREE RETENTION PLAN I r0N z W 5 n O J W W DATE: C)09/29/2023 FIELDBOOK: w PAGE: DRAWING NO: Ir—n V Q SHEET: 2 OF: C) LO N 1 O 1 0 W 1- LU 75 O 2 Z O 1- 1- Z LU 75 nG n O J W W ('11 W J 1- c/ ) U DocuSign Envelope ID: 6EECFSB6.602A-4E4A-B436-A317AA638878 JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS- USE STAPLES, WIRE RINGS. OR EQUIVALENT TO ATTACH FABRIC TO POSTS l 7xV 14 GAUGE WIRE, OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED 2'MIN FILTER FABRIC 9' MAX- �RGST SPACING MAY BE INC.RFASED OXI USED < 4'MINTRENCH I I� J BACKFILL TRENCH WITH NATIVE SOIL LJ OR IW TO 1-112" WASHED GRAVEL VIC WOOD POSTS, STEEL FENCE POSTS, OR EQUIVALENT (TYP.) NOTES: F 1 CONDITIONS❑ USE 1.1. SILT FENCE MAY BE USED DOWNSLOP€ OF ALL DISTURBED AREAS. 1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS 17INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENTTRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS. 2.1. THE GEOTEX TILE USED MUST MEE T THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATfONS MUST BE AVAILABLE ON STE- ADS (ASTM 047511 ID-1110 SIEVE SIZE {t}.6G-4.15mr11} FOR SILT FILM 50-100 SEVE SIZE (D.3". 15mm1 FOR OTHER FABRICS WATER PERMTTTNFTY iASTM D4491) O.G2 SEC' MINIMUM GRAB TENSILE STRENGTH (ASTM D45321 1S3LSS. MIN. FOR EXTRA STRENGTH FABRIC 100 LAS. MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM 04932) 3046 MA}L (WOVEN) ULTRAVIOLET RESISTANCE IASTM N3551 70%MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE: WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGE R FENCE. 2.3- WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT HE STEEPER THAN 2H:1 V 2.4. IF ATYPICAL 81LT FENCE IS USED, THE STANDARD 4-X4' TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM S INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE 2.5. FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE. 3. MAINTENANCE STANDARDS 3.1 ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY 3. 2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3: R IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATt014 OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT, 14. SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH. 3.5. IF T HIE FILTER FABRIC (GEOTEXTILE) HAS OF TERIORATEO DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED_ UNLESS OTHOWISE NOTED, DRAW LNG IS NDT TO SCALE [NTS; AdmlbL STD. PLAN - 214.00 PUBLIC WORKS Ps DEPARTMENT SILT FENCE GAZ 912812018 I - (9ronxwwwwmnimaa RATE .45 M CASTLE DEVELOPMENT TOWNHOMES RECORD DRAWINGS SW 114 OF SE 114 OF SECTION 18, T. 23 N., R. 05 E., W.M. CITY OF RENTON, STATE OF WASHINGTON DocuSign Envelope ID:6EECFSB6.602A-4E4A-B436-A317AA638878 V MAX DRAINAGE GRATE TRIM GRATE FRAME _ COVERFLOW BYPASS i BELOW INLET GRATE DEVICE SEDIMENTAND DEBRIS s '` FILTERED WATER SECTION VIEW DRAINAGE GRATE (RECTANGULAR GRATE SHOWN) RETRIEVAL SYSTEM CTYP.) OVERFLOW BYPASS(TYP.) BELOW INI-ET GRATE DEVICE ISOMETRIC VIEW NOTES: 1. PROTECTION SHALL BE PROVIDEO FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN Sq6 FEET OF A DISTURBED OR CONSTRUCTION AREA. UNLESS THE RUNOFF THAT ENTERS THE CATCR BASIN WILL BE CONVEYED TO A SEOIMENT POND OR TRAP. 2. INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3, THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4. SIZE THE BELOW INLET GRATE DEVICE (BIGOT FOR THE STORMWATER STRUCTURE 17 MOLL SERVICE. 5. THE BIGD SHALL HAVE A BUILT-IN! HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS). B. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL_ 7. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION M1.8i15j. B. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE. THE FILTER ME01A FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY. UNLESS OTHE ANISE NOT0. DRAWING IS NOF TO SCALE (NTS} STD, PLAN - II6.30 URPUBLIC WORKS APPIt F°' DEPARTMENT CATCH BASIN INSERT IGAZ 9/29/2018 1 wr�wwaa.."idmo. DATE pHILI,a waste ncom 0 ED ass ENGINEERING & SURVEYING Western Washington Division 38375 w� 165 NE Juniper Street, Suite 201 • Issaouah, WA 98027 • Phone: (425) 392-0250 � IscE �l ' Eastern Washington Division SIONAL 407 Swiftwater Blvd. ■ Cle Elum, WA 98922 ■ Phone: (509) 674-7433 0912012023 N 0 . REVISION :45 At DocuSign Envelope ID:6EECFSB6.602A-4E4A-B436-A317AA638878 R=2S'MIN.� INSTALL DRIVEWAY CULVERT IF THERE IS A ROADSIDE DITCH PRESENT, AS PER C17V ROAD STANDARDS 4'•6" QUARRY SPALLS --A GEOTEXTILE IV MIN. THICKNESS 1DD' MIN 1 DRIVEWAYS SHALL BE PAVED TO THE EDGE OF THE RIGHT -of -WAY PRIOR TO INSTALLATION OF THE CONSTRUCTION ENTRANCF TO AVOID ❑AMAGING OF THE ROADWAY. 2. IT IS RECOMMENDED THAT THE ENTRANCE BE CROWNED SO T I IA - RUNOFF DRAINS OFF THE PAD 1 S' MIN. PROVIDE FULL WIDTH OF INGRESSJEGRESS AREA NOTES: 1. CONDTTON QF USE 1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUC7N]N SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1p61) FEET OF THE SITE I-L FOR RESIDENTIAL CONSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE IN ADDITION TO THE MAIN SUBDIVISION ENTRANCE STABILIZED SURFACES SHALL BE OF SUFFICIENT LENGTI- MIDTH TO PROVIDE VEHICLE ACCES&PARKING, BASED ON LOT SIZPICONFIGURATION. 2. DESIGN AND INSYALLAYION SPECIFICATIONS 2.1. A SEPARATION GEOTEXTILE SHALL BE PLACED UNDER THE SPALLS TO PREVENT FINE SEDIMENT FROM PUMPING UP INTO THE ROCK PAD. THE GEOTEXULE SHALL MEET THE FOLLOWING STANDARDS - GRAB TENSILE STRENGTH (ASTM D4932) 2D0 LBS. MIN. GRAB TENSILE ELONGATION "TM D46M) W% MAX. (WOVEN) CBR PUNCTURE STRENGTH "TPA D6241) 495 LBS. MIN. ADS (ASTM 04T51) 20-45 (U.5_ STANDARD SIEVE SIZE) 2.2. DO NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLORIDE FOR CONSTRUCTION ENTRANCE STABILIZATION BECAUSE THESE PRODUCTS RAISE W LEVELS IN STORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE IS PROHIBITED. 2.3. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBIN ED WITH QUARRY SPALLS IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT. 2.4. FENCING 5HA1 L BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE. 2.5. WHENEVER POSSIBLE. THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRAOE. THIS CAN SUBSTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE 3. MAINTENANCE STANDARDS 11. QUARRY SPALLS SHALL BE ADDED IF THE PAO IS T40 LONGER IN ACCORDANCE WITH THE SPECIPECATMNS. 3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE. DR THE IN5TALLATION OF A WHEEL WASH. IF WASHING i8 USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK. AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND 3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET. EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE 11 GAIN BE CONTROLLED AND DISCHARG>=D APPROPRIATELY. WASH WATER MUST BE PUMPED BACK ONTO THE S!T£ANO CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TO SURFACE WATERS. 5.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 3.6. IF VEHICLES ARE ENTERING OR EXITING THE SITE$ AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE($), FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC. STD. PLAN - 215,10 1�� ] DEPARTMENT PUBLIC WORKS STABILIZED CONSTRUCTION ENTRANCE PG EAZ 9/28/2018 - ro�wwwwmnieiam RATE SURVEYED: BUI DESIGNED: IWD DRAWN: TNF CHECKED: IWD BY DATE APPR APPROVED: CP SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM :45 Al DocuSign Envelope ID:6EECFSB6.602A-4E4A-B436-A317AA638878 EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE 1NCORPORATEO IN THE EROSION AND SEDIMENT CONTROL (ESC) PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR CWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL HE ADDED AFTER THE ESC STANDARD PLAN NOTES. 1 BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF PENTON. HEREBY REFERRED TD AS THE CITY, THE APPLIGANT, AND THE APPLICANTS CONTRACTOR, 2_ THE APPLJCANT IS RESPONSIBLE FOR OBTAINING THE WASH INGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORMWATER GENERAL PERMIT, IF IT IS REQUIRED FOR THE PROJECT_ THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO 1=COLOGY ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT. 3. THE ESC PLAN SET SHALL INCLUDE AN ESC CQNSTRUCTJON SEQUENCE DETAILI NG THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION COMMENCEMENTTO POST -PROJECT CLEANUP iN ORDER TO FULFILL PROJECT ESC REQUIREMENTS. 4_ THE BOUNDARIES OF THE CLEARI NG LIMITS, SENSITIVE AREAS AND THEIR BUFFERS, AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE F IELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS 54ALL HE MAINTAINED BY THE APPLJCANDESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION 5. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT ADDITIONAL MEASURES. SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK -OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. OR MORE FREQUENTLY DURING WET WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING WATERS OF THE STATE. 6_ WASHOUT FROM CONCRETE TRUCKS ShVLLL BE PERFORMED DFF-GTFE OR IN DESIGNATES] CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN PITCHES. ON DUMPI NG OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE WASHOUT AREAS. 7. ALL REQUIRED ESG BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AHDYOR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES, ALL ESC BMPS SHALL BE MAINTAINED IN A SATI SFACTDRY CONDITION UNTIL SUCH TIME THAT CLEARING A.NWOR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR 0"ME EROSION DOES NOT EXIST_ THE IMPLEMENTATJON, MAINTENANCE- REPLACEMENT, ENHANCEMENT, AND REMOVAL OF E5C BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT. 8- ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POULITE RUNOFF SHALL BE DISPOSED OF PROPERLY. 9. THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE T11E OBLIGATION AND RESPONSIBILITY OF THE APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AN➢ WATER DUALITY OF THE RECEIVING DRAINAGE SYSTEM. 1D, APPROVAL OF THIS PLAN IS FOR ESC ONLY. FF DOES NOT CON&T FUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICT❑RS, CHANNELS, OR STORMWATER FACILITIES. 11 ANY DE WATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OFSTORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 12. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1ST THROUGH APRRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON (MAY TST THROUGH SEPTEMBER 30TH) SHALL 9E IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS E.G. SEEDING MULCHING PLASTIC COVERING ETC, IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM. f 1 N 13. WET SEASON ESC REO1-1€REMEN75 APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER I ST AND APRIL 30THC UNLESS OTHF_IYWISE APPROVED BY THE CITY_ 14 ANY AREA NEEDING A➢PIf ZONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTIQN, SHALL 6E ADDRESSFP VATHIN SEVEN (7) DAYS, 15 THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY 16 BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216.30 SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 50D FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP ALL CATCH BASIN HJSF_RTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION. 17. AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED W3 OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAYING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM. 18. ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. iF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE TEMPORARe FACtLJTV SHALL BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY_ 19. AREAS DESIGNATED ON THE PLAN(S) CONTAINING EXISTING STORMWATER FACILITIES OR ONSLTE BMPS (AMEKBFD SOILS, 61ORET€NTION. PERMEABLE PAVEMENT, ETC.) SHALL SE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION 20. PRIOR TO THE BEGINNING OF THE WET SEASON OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW. 21. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT BATE SHALL BE STABILIZED TO PREVENT SEOIMENT-LADEN WATF�R FROM LEAVING THE PROJECT SITE, ALL ESC BMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND DN-SFTE BMPS SHALL BE RESTORED TO THEIR FULLY FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A MINIMUM, DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL. MULCH WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER IST. 22. ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES tN CITY ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS_ ROCKERIES OUTSIDE OF ROAD RIGHTS -OF -WAY SHALL 9E CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE STD. PLAN - I68.00 PUBLIC WORKS EROSION AND SEDIMENT CONTROL PPa °" UR DEPARTMENT �7161Z 9/28/2018 I STANDARD PLAN NOTES NUIPr"wwwaa.�i�.ia DATE Know what's below. Call before you dig. e C TY 0E RENTON Planning/Building/Public Works Dept. It O O O I INr' U i O O N N W, Lm 45 fij DWG R-421503 � IN COMPLIANCE WITH CITY OF RENTON STANDARDS CASTLE DEVELOPMENT TOWNHOMES AS -BUILT TESC DETAILS Z W 5 n O J W DATE: W 09/29/2023 FIELDBOOK: u„1 PAGE: DRAWING NO: 1- U) SHEET: 3 OF: / \ w 75 O z O z CW G n O LL1 > LL1 LU J Q U CI W P2 Q U I n N N w Q z L, AS -BUILT NOTE: LOCATIONS AND DIMENSIONS OF AS -BUILT STRUCTURES AND UTILITIES HAVE BEEN OBTAINED FROM FIELD MEASUREMENTS AND OBSERVATIONS PROVIDED FROM THE CONTRACTOR AND NOT BY SURVEY. a 0 N CASTLE DEVELOPMENT TOWNHOMES RECORD DRAWINGS SW 114 OF SE 114 OF SECTION 18, T. 23 N., R. 05 E., W.M. CITY OF RENTON, STATE OF WASHINGTON I � z .. a . Of d, •d w � 0 a ° I SEE NORTH SIDEWALK DOWNSPOUT . CONNECTION DETAIL CONNECTION m THIS SHEET FOR IE=24.98 GRADING DETAILS ° d. d d d d ° e = :...a •.. OW DEDICATION - SD SD - SD - - Q „ I 4' PERMEABLE . . . . . . - - - =, :' PAVEMENT FG=27.0 o WALKWAY f- _ ROOF DRAIN UNIT C 27.75 DOWNSPOUT CONNECTION FFE=�S IE=25.2 27.75 . 10 LF PERFORATED PIPE CB. 10. CONNECTION PER COR RIM. E L.. a STD PLAN 263.40 (TYP) 25.64' .1 E= 23.7.4'- . a . IE=23.74' „ TYPE 1 CB, W/ SOLID LID c� PER COR STD PLAN 200.00 AND COR STD PLAN 225.00 N _ RIM=26.7 2775 12"IIE 24.1 ((W)) rTT- Q " LU SDMH #1 UNIT B TYPE 2 RIM E L, U :. ':.4.. PERM ABLE FFE=z�$�5- 26.51 ' :. . PAWME:.T `• ' •'. 27.75 IE=16.51' WA�KA' 10 LF PERFORATED PIPE _ o CONNECTION PER COR STD PLAN 263.40 (TYP) ROOF DRAIN 27 .. . y DOWNSPOUT CONNECTION IE=24.5 BSBL (TYP) ROOF EAVE UNIT A o MID) . I FFE=28. 7 27.75 r .' ••PA•R�E ' 'B�. ... AL W D SD SD SD r _ FG=26.6 . . . . . . . . . . . . . r o _J d 6" ROOF DRAIN ® ROOF DRAIN o d . SDCO (TYP) 0.50T MIN PER COR DOWNSPOUT STD PLAN 225.0 (TIP) CONNECTION SEE SOUTH SIDEWALK IE=24.60 d d, I CONNECTION DETAIL THIS SHEET FOR GRADING DETAILS SAWCUT EXISTING SIDEWALK (TYP) Encomt)ass ENGINEERING SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 ■ IssaQuah, WA 98027 ■ Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. ■ Cle Elum, WA 98922 ■ Phone: (509) 674-7433 U �pHILIp WAsh'IAj'd I ssIONALCs 0912012023 REVISION i "E OVERFLOW TO SOCO IE=25.1 6 x2O' LIMITED INFILTRATION TRENCH PER DETAIL SHEET 7 TOP OF ROCK=26.0 BOTTOM OF ROCK=24.0 IE=25.0, 6" 0 5 10 SCALE 1 " = 10' FG 28.0 28.5 UNIT C GARAGE :' ::.:::. •': .:•:: FFE=28.5 � �•: ; .: • �..''.:•'....•'.':.'.': • .': •'.': •'.... .b ROOF DRAIN/DOWNSPOUT CONNECTION : ' : , ': ; • ':: IE=25 5 - • dS AREA DRA N .•'• .., RIM=27.0 UNIT B GARAGE . IE=25.0, NE) FFE=28.0. ... <C .: 28.0 ` CONCRETE PAVEMENT AREA DRAIN WALKWAY (TYP) RIM=27.0 IE=24.6, 6 (S.E) •� SURVEYED: BUI DESIGNED: IWD DRAWN: TNF CHECKED: IWD AP P R APPROVED: cP ...� _memo FG=27.0 27.5 - ROOF DRAIN/DOWNSPOUT "•':ur: '.': '.': ':' CONNECTION IE=25.5, 6" UNI T A GARAGE Q FFE=27.5 ::. 27.5 n' =270 7 OVERFLOW TO SDCO 5'x12' LIMITED IE=24.70 INFILTRATION TRENCH PER DETAIL SHEET 7 TOP OF ROCK=25.6 BOTTOM OF ROCK=23.6 IE=24.6, 6" SCALE: 1 "=10' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M Know what's below. Call before you dig. CITY 0E RENTON Planning/Building/Public Works Dept I 1 I 1 I 2" HMA GRIND AND OVERLAY 1 FULL ALLEY WIDTH 1 I I I SAWCUT AND I REPLACE ASPHALT I (TYP.) 1 I EG 26.47 EG 26.63 1. Z (29. 1 fA)O Q 10 W QFG 26.50 NORTH SIDEWALK CONNECTION SCALE. 1 "=5' FG 26.24 EG EG 26.13 26,22 MATCH / I <d SOUTH SIDEWALK CONNECTION SCALE. FG 26.66 FG 26.62 - 26.36 26.32 Q 6" POROUS CONCRETE OR PERMEABLE PAVERS p p p p p 8" THICK i'-14" WASHED FRACTURED ROCK PERMEABLE PAVEMENT DRIVEWAY SECTION NOT TO SCALE Q 4" POROUS v a: Q CONCRETE OR PERMEABLE PAVERS p p p p p 6" THICK f-14" WASHED FRACTURED cz ROCK PERMEABLE PAVEMENT WALKWAY SECTION NOT TO SCALE DWG# R-421504 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CASTLE DEVELOPMENT TOWNHOMES AS -BUILT PRELIMINARY GRADING AND DRAINAGE PLAN DATE: 09/29/20 FIELDBOOK: PAGE: SHEET: OF: 4 7 O O O O O N N W u LLI 2 O z O z W 5 n O J W > W 0 LU I- a U 0 N N O O O O i N N ry n LO ti CD O O O N N W u W 5 O z O z w 5 n O J W W 0 W LJ 1 a U Lo to � N N N O � N ~ /`NLLJ 0 5W L O 2 Z O I- I- Z 5W n 7 O W W r') LU Ir-n V J U R 0 W P2 Q U I n n N N w Q z LLJ LOT LINE, TYP. W DIA MIN ROOF DRAIN 5' MIN. STUB WITH CLEANOUT (TYP) (TYP I, HOUSE (TYP) I I r 3' MIN - PRIVATE TYPE 1 CATCH BASIN I I - PRIVATE ROOF DRAIN COLLECTOR PIPE: 6' DIA MIN„ 0.5%MIN . SLOPE. 2 FT MIN. COVER I I PRIVATE JOINT SD SO SC UTILITY EASEMENT CURS. CITY STORM DRAIN SYSTEM SIDEWALK 5' MIN. WIDTH ISO) R.O. W LINE PRIVATE STORM DRAIN (SO) SYSTEM, B' MIN. OIA PIPE, SEE NOTE 1 ROOF DRAIN TO CONNECT INTO CITY CATCH BASIN (CB), MIN. SIZE TYPE I CLEANOUT, TYP AT EVERY 90", OR 2ND 45' BEND. AND AT 100' MAX. SPACING ON STRAIGHT SECTIONS - NOTES: 1. SEE STO PLANS 220 00 AND 220.10 FOR PIPE MATERIALS AND MINIMUM COVER REQUIREMENTS. 2 THE ROOF AND FOOTING DRAIN SYSTEMS ARE PRIVATELY MAINTAINED 3. FLOW PATTERN SHOULD BE TO THE NEAREST CS IF GRADE ALLOWS, OR TO THE NEXT DOWNSTREAM CB. 4, ROOF DRAIN COLLECTORS MUST BE ANALYZED FOR CAPACITY, SIZED FOR 25-YEAR PEAK FLOW. 5. PVC PIPE MUST BE SDR 35 OR THICKER AND MEET THE REQUIREMENTS OF ASTM D3034. 6. PVC PIPE USED IN PRIVATELY MAINTAINED DRAINAGE SYSTEMS MUST BE WHITE IN COLOR. 7. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS 8. AREA DRAIN WITHIN CRAWL SPACE IS ALLOWED TO CONNECT INTO THE STORM DRAINAGE SYSTEM WITH THE FOLLOWING CONDITIONS: A THE CONNECTION IS TO BE TIGHT LINED A MINIMUM OF 10 OUTSIDE OF THE FOUNDATION, AND IN NO CASE CONNECTED UPSTREAM OF THE FOOTING DRAIN SYSTEM FOR THE HOUSE B. THE AREA DRAIN MUST BE ROUTED THROUGH A SUMP PUMP SYSTEM PRIOR TO CONNECTION TO THE PUBLIC STORM DRAINAGE SYSTEM TO HELP PREVENT BACKUP DURING SURCHARGE CONDITIONS UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NT% STD. PLAN - 22S.00 PUBLIC WORKS TYPICAL PRIVATE STORM DRAIN e11 y: URDEPARTMENT COLLECTION SYSTEM Aartin Pastucha 8/13/20 Yti3;t{t DaeBAtvD DATE Ex. SEWER MAIN i I PROPERTY LINE SPOOL 1 1 1 2 I (LENGTH AS NEEDED) I I I X-O" MIN I I 6" SEWER STUB I I 1 I FUTURE 4' SIDE SEVER ( DC`---------' 1 1 1 / `\ i i I I I Y"x 4" STUD MARKING POST PAINTED 1 1 1 I 6• CAP JJ WHITE WITH ME WORD 'SEWER' STENCILED SEWER MAIN TEE % 6" TEE j I j I IN 3" HIGH BLACK LETTERS AND 06 WIRE i i 1 SIDEWALK i W WRAPPED AROUND THE STUD AND 1 1 1 I i - EXTENDED TO THE TOP OF THE STUD i COUPLING TYP 1 1 1 1 .aA I # 6'X6'X6' SURFACE CLEANOUT WITH CAST IRON RING AND COVER O (EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR APPROVED EQUAL. SPECIFY 'SEWER' ON LID). fT} CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAO (Ix CONCRETE PAO TO BE 6'IN DEPTH - i 1 r TT BEND AS g" REQUIRED /EXISTING SANITARY 1 SEWER MAIN-2.07G 41N SLOPE \\7 `FUTURE 4' SIDE SEWER \ 6" SEWER STU9 6"X6"%6" WYE 1FUTURE 6"x 4" REDUCER SEWER MAIN SIZE X 6" TEE ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER 1111I A VITRIFIED CLAY MAIN - CUT IN A NEW PVC 'TEE' USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B CONCRETE MAIN - CUT IN A NEW PVC 'TEE' USING "STRONG -BACK- FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL) C PVC i C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) 0, DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E LINED MAIN - CONNEC LION TO SEWER MAINS THAI HAVE BEEN LINED (CIPP, ETC). CUT IN A NEW PVC "TEE- USING 'STRONG -BACK' FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL), F HOPE - CORE -DRILLED WITH A ROMAC SADDLE 'INSERTA-TEE" MAY BE USED ON SEWER MAINS 12' DIAMETER OR LARGER G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALT. BE CORE -DRILLED AND USE NOR-N-SEAL BOOTS OR APPROVED EQUAL NOTES. 1 PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT 2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 25' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER 3 SIDE SEWERS SHALL HAVE A MINIMUM 2 S SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR 4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT THE APPOINTED TIME DO NOT BACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR 5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102 6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDO'NG IN ACCORDANCE WITH STANDARD PLAN 405 ALL SIDE SEWER STUBS SSA SE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON SIDE SEWER STUB 51-D.PLAN -406.1 U{-T - UPUBLIC WORKS INSTALLATION T'C DEPARTMENT Martin PastuCfaW26/202 (SEWER MAIN TO PROPERTY LINE) .,....I..."..rr DATE EncomDass ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 201 - IssaQuah, WA 98027 - Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. ■ Cle Elum, WA 98922 ■ Phone: (509) 674-7433 12: I CASTLE DEVELOPMENT TOWNHOMES RECORD DRAWINGS PACE OF CURB 61l2' Y In" R- y t"Ft. t:24 I L TOP OF IMP, ROADWAY T f� J w 1 - t,•6" � T CEMENT CONCRETE TRAFFIC CURB AND GUTTER FACE OF ADJACENT CURB y 6 1F2'_y FLUSH WITH GUTTER PAN AT SI DE WALK RAMP ENTRANCE :2 t24 TOP OF 112" R. ROADWAY „ i tlt DEPRESSED CURS SECTION AT SIDEWALX P-WPS 3917 SW 114 OF SE 114 OF SECTION 18, T. 23 N., R. 05 E., W.M. CITY OF RENTON, STATE OF WASHINGTON n CEMENT CONCRETE 117 - _ 1"Ei SIDEWALK RAMP VARIES OR LANDING FROM I { VTO0 I 6' T SIB' PREMOLCED JOINT FILLER CEM ENT CONCRETE PEDESTRIAN CURB AT SIDEWALK RAMPS AND LANDINGS FACE OF ADJACENT CURD -6t✓2�� SEE DEPRESSED CURB DETAIL THIS SHEET I L•2A TOP OF 1Y2' R. ROADWAY 1. 2" 1 DEPRESSED CURB SECTION AT RESIDENTIAL DRIVEWAYS ONLY. FOR GgMMEERCIAL DRIVEWAYS SEE STD PLAN 104.2 FACE OF CURB FACE OF ADJACENT CURB • . 4l ', • GUTMRSURFACE PREMOLDED J01 NT FILLER E FULL -DEPTH EXPANSION JOINT 131F!' - 61F2" T" Srt R. - 1' R 1 I TOP OF ROADWAY I � V I s tI4- CEMENT CONCRETE TRAFFIC CURB DEPRESSED CURB DETAIL AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS. AND ALLEYS GENERAL NOTES: 1. Sea standard plans 102 OW 101.1 fol aah expansion and contraction joint -spacing. 2. Expamion joint shall he full depth, 3/6" (In.) lommolded point 6Oer. 3. For Depromd Monolithic Drlvexay Curb A Gutter SacWn, sad Standard Plan 104.2 STD. PLAN - 101 O1'PA R'P4fENT a P1WORCEMENT CONCRETE CURBS /1 flA ALL 912 TURNS SHALL BE ACCOMPLISHED BY MAINS OF A WYE OATH CLEANOUT AND 4' BEND AS REQUIRED (NO L1t1EATER 45 BEND TWO 45' BENDS SHALL NUT' BE THAN AS' BEND) EVERY 2NB CHANGE C CLEANd1I WYE 0TH ACCEPTABLE (SEE NOTE TI) IN DIRECTION OR CRAVE WILL REQUIRE 45 BEND AND PLUG A CLEANOUT WYE (SEE NOTE 11) I (SEE NOTE 11) I ' HOUSE H0115EI HOUSE$I HOUSE m 3 0•' MWIN Iy 4- SFWIeR PIPE SURFACE CLEA40UT 4" SURFACe 15". 6"x6" WYE t CLEA,IOVT (TYPICAL) 4•' SEWER -'PC. SEE NOTES 2 (Sa STO PLAN - 4C7) WYE r 4' TEST TEf WITH AND 3 MINIMUM UNE SITE FOR a" W' WITH 11 PLUG FACE UP DTHER :)TAN SINGLE FAMILY IS 6 I ROW LiITi I CLEAINOUT (TYPICAL) O % LINE I 3' MIN V 6"x 4" REDUCER V (TYPICAL) F MAIN SEWER LINE O ES IF THE SUFLOWC SEWER SERVES ANY FIXTURE HAMN O FLOOD LEVEL Rw5 LOCATED BELOW THE ELEVATION T PRIOR 10 LNSTALLATION OF A SANITARY SEWER CONNECTION, A a OF THE NEXT UPSTREAM MANHOLE COVER OF THE SIDE -SEWER PERMIT MUST BE PURCHASED FROM THE CITY OF a PUBLIC SEWER SYSTEM. A BACKFLOW PREVENTION RENTON PUilUC WORKS DEPARTMLNT DEVICE SUCH AS CLEAN CHECK EXTENDABLE • g BACKWATER VALVE OR APPROVED EQUAL SHALL BE 2 FOR INSPECTION OF SIDE SEWER, CALL Z4 HOURS IN ADVANCE INSTALLED THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER PERMIT Ly 4" FLEXIBLE COUPLING IFERNCD OR EQUAL] SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE YMEN INSPECTOR ARRIVES AT APPQINTT4 TIME 00 NOT BACKPLL THE DITCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR SURFACE ELCANDUT to 4"x 4"AC WYE 3 SIDE SEWER PIPE AND FITTINGS SHALL BE PVC SOR 35 WITH RUBBER 4" PWmG GASKET .0NtS. UNLESS OTHERWISE APPROVED BY THE PUBLIC PLJ1N WORKS DEPARTMENT BUILDING DRAIN FOR 4 A MINIMUM GRADE OF Z% (1/4" PER FOOT) MUST BE MAINTAINED LDW ELEVATION HOUSE WITH A 4' PIPE IN THE EVENT A 2x GRADE CANNOT BE MAINTAINED WITH THE APPROVAL OF THE PUBLIC WORKS INSPECTOR, THE MAIN TO CONTRACTOR MAY INSTALL A 6' MAMETER %C SEWER AT NO LESS g FEET R D w LINE RID W- LINE TO CLEANOUT Y. A THAN M SIDE SEWER BUILDING SEWER BUILDING STUB DRAIN 5 INSTALL SIDE SEWER WITH 2' WNIMUM COVER 16- COVER IS ALLOWED FEET MINT l­- AT THE HOUSE IF OII TLf F IS SHALLOW �3 6 ALL BUILDING SEWER AND 5FDE SEWERS SLIALL HAY[ BEDDING IN j/ ACCORDANCE h11[TN STAHQARp PLAN 405 q w% °: ? 'A ... 7 WHENEVER FEASIBLE, THERE SHALL BE A MINIMUM S FOOT v fjx� im DO --.5 '5 HORIZONTAL SEPARATION BETWEEN SANITARY SIDE SEWERS AND ALL .. 1+ n S 3 # 9 x OTHER UTILITIES El SUE SEWER TESTING SMALL CONSI5T DF PLACING A PLUG IN THE ut F lad v 2 n TEST TEE AND INSTALLING A 4-FOOT RISER PIPE ON THE CLEANDUT 4 o w AT THE BUILDING- THE SIDEWE SEWER PIPE SHALL BE FILLED TO WITH 3 WATER TO THE TOP OF THE RISER PIPE LOSS OF n I1 n NO wAT{R SHALL OCCUR FOR A PERIOD Or 10 MINUTES, THE SIDE SEWER MAY BE -.- - v CONNECTED TO THE RUILOING FOLLOWINC THE SUCCESSFUL m COWLET104 OF THE LEAK TEST 9 1HE CLEANOUT AT THE RICHT-OF-WAY SHALL BE INSTALLED PER n P--�-A-.N STANDARD PLAN 4061 THE QUeANOUT AT THE BUILDIFIC SHALL W BUILDING SEWER INSTALFFO TG SURFACE GRADE ALL OTHER CLEMOUTS SHALL BE INSTALLATION INSTALLED TO WITHIN 12' 07 THE SURFACE 10 U SIDE SEWER STUB IS Not AVAILABLE THE OWNER SHALL BE RESPONSIBLE FOR ITS INSTALLATION PER STANDARD PLAN 4051 ALL WORK WITHIN SIREEI RIGHT-OF-WAY SHALL BE DONE BY A LICENSED AND BONDED CONTRACTOR CALL BIT BEFORE YOU DIG 11 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC DF g0 t0 RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102 www calibeloreyoud,9 Or[) 12 ALL WORK S--41L BE ACCCMPIPHED IN ACCORDANCE WITH FHE WASHINCTON MCIOSTRIAN- SAFETY AND HEALTh ACT (MSRA) TYPICAL BUILDING SEWER STD. PLAN -406,2 7 PUBLIC WORK$�cylg seer -±C DEPARTMENT FROM PROPERTY LINE TO artin PaStUchI126/202 BUILDING CONNECTIONDATE "FD9m68449D ' Ir ` 38375 - is SSIONAL 0912012023 NO. REVISION e' RAISED EDGE DETAIL _ SIDEWALX LEVEL ,� ExTEKD SIDEWALK TRAxSYEHSE l•P T-P' m•IIr7)R JOI NTS TO INCLUDE RAISED EDP Sa'(kI] WHERE APPLIOMFILLR TYPICAL LVHFBE APPLICADis: Rau DING 2-D% -s ,rr (rNI R frrP.1 i FOR CL1R8 pE'FAIIS -1. � k ► • + 1.a% SEE STD RAN 101 •� j 1'{INDR . �• _tiN •. y HNGROADWAY A • 4,�,'" `"" r l. + •w .t� CRU5HEB ROCK axS SEC RAISED EDGE f ,I+ 5'•D'- SIDCwALK DETAIL -TI0.3E `T3'PIGL UNPOT ORUSHED SURFAgNO TOPCOURSE(GSTC1 SIDEWALK CAN PA C; ICI 95X WCUIFIE3 PRpL iO� AIL MIN WITHRAISED=15; =LDS r ryrGmE.S R;,T)TCEME h0M ALL u ENGmERR1 TYPIG4L UNDER ALLCURB, ,rt (IBJ R [rYP-I GLITTERS 510-iVALK I:STC UNDER 2.67L T FOR CURB DETAILS O[1BB d OUTTER TO B26-Tt11CKNEs9 OR 1.5% %%% SEE STO PLAN 101 MATCH IM$THNG RGA0 WAY SAWHGQ R00K BASE, WHICHEVER IS GREATER VW. FOR AH�Y(FP- All CURB 6CaTCTERI 4 I, TOPEDON R 1•(INIBmW 1 TOP of nDNCRETI' BURPACE 7•P SIDEWALK ADJACENT- TO CURB t'-0• 1•-1Y PIN ROLL DING IYC GIN) R [GYP 1 FOR CURB DETALS 2Yh Ir 15% -: v N SEESTOmmla1 ;,.� • I BRIDGE DR PEOESTIR" ySyE7�'; kNDNG � .SY�' . FOR CURB OFTARS ADJACENT TO CURB BARRIER - SCE SIDEWALK Sa STU PLAN MI (STEEP FILL SLOPESl COYTRACT PLANS - F•---;vat OR BARRIER I 7TY TINT R. TTYP.1 .j f I SIDEWALK RUSH +fix •'��- 1fZ' N]R VERTICAL WALL- 5 •"�' SEE D7 TAIL Ye' Wi PREMCLOW JOINT F21ER �Ny ADJAGENT TO CURB AND RAI LING OR WALL PRO.t o JOINT FILLER FOR SIDE RUFFCR STRIPTREATMENT 51DEWNJC SI DEWALK ADJACENT TO WALL IJETAIL SIDEWAIx (SEE NOTE "I SECTIONS 1r2'(IhT A. t fTYP 1 FIXL CURB DETAILS 1'W +3x MAIL SEE BTO PLAN 1p5 BROOWD FINISH ORMATCH EXH511NG . H ,D• 4•IyOE SMOOTH I �1 TROWELED PERWITTrR FINISITYP GRADE 1' R P BELOW ,- FL J OONGRETEPAVED L SURFACE FOR PLANTIIK1- FLUSH N PAVED CEMENT CONCRETE CURB ADJACENT TO BUFFER STYUP J "-•� (CURB AND GUrTFRS-LOWN FOR CURB DETAILS �•D' SEE STD PLAN 101 r�t NOTES Tr6-TO1r4' r \ 1. Four fact Dfthe Slw(d[h 9hB0 CONTRACTION JOIN r ► by the minimum pe3destrdDabian % -�� � [N s1oEY+ALN ONLr T• .,�. BCCBasINO muge IAA,^., fNm of vE,rtkml / , 1. RJ`FL "• and hortzontel ahs. Gr4Ug9, ALnm3 FoYasJunction ��� A • • r ,.r Boilaa, FULL-0EP7TH LxPANgK1H JOIHTIN BOTH • Cable VeUIfs, Pull BOXBs and dKher �L - CURB AND SIDEWALK rin IoFu im i mLq eppurlenanca V11.hrn tha 9ldawallk 2W C CONTRACTION JOINT must be Ouch whh surface, and match \ grade Of vm aidewall. JOINT AND FINISH ` DEIAIL r s 2. MwQIW1 Cement Conuete Curb and I • ' Sldewalk lL not perrRlned In new For other eafaronced NOTES see *'+' • C, R� wWAFLtticn, When replacement work STD PLAN 104.2- a' neccsit-ales R Manolio C Cement 1OLD E COnCFEW Curb kdld per W5PDT pREh PRER ULD JOINT Standard Plan F-30.1 M3. Paved surfaces must cornply sash E FULL-DEPTH3. Conuete to Ne 4,000 PSI. STD PLAN 102-1 a6 applicable. EXPANSION JOINT - a PUBLIC WORKS CEMENT CONCRETE M. PLAN 102 DEPARTMENT 7 sloEw►rs,Rx j{ r DocuSign Envelope ID: 3B1B34D3-7EOA-476C-ADB3-4329FFEOC108 SEE NOTE 2 10' MIN. 5MIN. a E r J" HOUSE YARD DRAIN OR CATCH BASIN ' PLAN WITH SOLID LID ROOF DOWNSPOUT WITH OVERFLOW WYE AND SPLASH BLOCK PERFORATED PIPE TO BE LEVEL FLEXIBLE GASKETED ETE. CAP PER ASTM CLEANOUT PER STD. PLAN 226.00 6" MIN. 6" MIN. F HOUSE Z MIN . MIN. PVC, L 35 PER ASTM D3034 WFR11N2F 3/4'TO 1-1/2" WASHED DRAIN ROCK 6" DIA. MIN. PERFORATED PVC, OR GRAVEL BACKFILL FOR SDR 35 PER ASTM D3034 DRYWELLS PER WSDOT STD EN, SS304 10x10 OR SIMILAR SPECIFICATION SECTION 9-03.12(5) COOMPACTED BACKFILL 6' MI/� 6" DIA. MIN. PERFORATED PVC, SDR 35 PER ASTM D3034 6-MIN.. \ NON -WOVEN GEOTEXTILE FOR SEPARATION ON TOP AND SIDES OF TRENCH PER WSDOT SPECIFICATIONS SECTION 9-33.2(1) TABLE 3 12' MIN. 12" MIN. ABOVE SEASONAL HIGH \V'\ X�/ GROUNDWATER OR HYDRAULICALLY r� RESTRICTIVE LAYER SECTION A NOTES: 1. 15' MINIMUM SETBACK FROM INFILTRATION TRENCH TO BUILDINGS WITH CRAWL SPACES, BASEMENTS, OR ELEVATIONS BELOW THE OVERFLOW POINT. 2. REQUIRED TRENCH LENGTH VARIES DEPENDING ON SOIL TYPE, UP TO 100- MAX. WHEN LOCATED IN COARSE SANDS OR COBBLES, INFILTRATION TRENCHES MUST BE AT LEAST 29 IN LENGTH PER 1,000 SQUARE FEET OF IMPERVIOUS SURFACE SERVED. WHEN LOCATED IN MEDIUM SANDS, INFILTRATION TRENCHES MUST BE AT LEAST 30' IN LENGTH PER 1,000 SQUARE FEET OF IMPERVIOUS SURFACE SERVED. 3. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 225.20 .•.� PUBLIC WORKS SINGLE FAMILY ROOF DOWNSPOUT aO°�edby: DEPARTMENT INFILTRATION TRENCH Oartin Pastucha $/13/202 ' b,QBk¢Q,9D... DATE SURVEYED: BUI DESIGNED: IWD DRAWN: TNF CHECKED: IWD BY DATE APPR APPROVED: CP SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M 13"x24" PLASTIC METER BOX EQUAL TO MID -STATES PLASTIC, INC. BCF SERIES MSBCF 1324-18 WITH 1,75- THICK DUCTILE CITY PRIVATE IRON DIAMOND PLATE COVER EQUAL TO MID -STATES PLASTICS, INC, MSCBC-1324-R WITH READER LID AND 2' DRILLED HOLE FOR TOUCHREAD PIT LID (SEE DETAIL A -A) 7) IN UNIMPROVED RIGHT OF WAY INSTALL METER BOX AT ? 1 r PROPERTY UNE WITH 12" r (r LONG COPPER TAILPIECE. w 9' MIN SIDEWALK a 12" MAX I FlNISH GRADE z a > TOUCHREAD WATER METER TO BE 12" 36" MIN COVER ry nv \ SUPPLIED BY THE <l CITY i TYPE "K' SOFT o � COPPER TUBING \ 22-1/Z NEW DUCTILE IRON WATERMAIN IF SERVICE LINE TO HOUSE IS 3/4" OR I" TO BE INSTALLED IN THE FUTURE GALVANIZED INSTALL FORD C14-33 OR 44 FIPT PLUG x COMPRESSION COUPLING LOOP DOWN TO CENTERUNE OF WATER MAIN TO PROVIDE SLACK IN COPPER COPPERSr-TER FOR 5/8"x3/4" METERrnp 5/8 0/4" ME�R: FORD SERVICE LINE TO METER. VBH72_15W-44-33G, OR McDONALD BRASS: 21-215WC0033, OR MUELLER: 3/4-6-247D-2 WITH ANGLE BALL VALVE ON INLET AND SINGLE CHECK VALVE ON OUTLET L CORPORATION STOP WITH BALL VALVE. FORD COPPERSETTER FOR 1' METER: FORD VBH72-15W-44-44G, OR TAPERED THREAD (CC). QUICK JOINT MCDONALD BRASS: 21-415WC0044, OR MUELLER: 1-B-2470-2 (3/4- FB1000-3-0) OR AY MCDONALD 4701E BOTH INLET AND OUTLET WITH QUICK JOINT, PADLOCK WINGS ON (1- FB1000-4-0) OR AY MCDONALD 4701E INLET ANGLE BALL VALVE AND SINGLE CHECK VALVE ON OUTLET. ALL FITTINGS SHALL BE WITH QUICK JOINT, NOTE: ALL METER BOXES INSTALLED WITHIN CONCRETE OR PAVED DRIVEWAYS SHALL BE CAST-IRON EQUAL TO OLYMPIC FOUNDARY. EXPANSION JOINTS MUSH BE INSTALLED ON BOTH SIDES OF METER BOX, RILL 2" DIA. HOLE FOR AMR (AUTOMATIC ETER READ) TOUCHREAD DEVICE 2-1/2" MIN. FROM NEAREST AND FRONT EDGE OF PIT UD NOTE: THE CENTER OF THE HOLE MUST BE AT LEAST 1" FROM UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS THE NUT TO TIGHTEN AGAINST THE OPEN SIDE OF MORE THAN ONE RIB. " PUBLIC' WORKS 34" AND 1" WATER SERVICE STD• PLAN - 920.1 ;O• DEPARTMENT f.N.. NOVEMBER 2009 DocuSign Envelope ID: A9707D3B-AOEF-441F-8140-2CDB48E878CA CONFIGURATION ON SLOPING GROUND DOWNSPOUT WITH CLEANOUT FILTER, SEE DETAIL LPE ER STD. PLAN 226.00 L TRENCH WITH PIPE, SEE NOTE 1 5'• MIN. ILLICI s I I� I CLEANO N PERI STD. PLAN 226.00 TO STORM DRAIN SYSTEM , I --- FOOTING DRAINBYPASS5MIN.. CLEANOUT PER STD. PLAN 226.00 TO STORM DRAIN SYSTEM DOWNSPOUT WITH CLEANOUT FILTER, SEE DETAIL h 10' MIN. LEVEL TRENCH WITH PERFORATED PIPE, SEE NOTE 1 1- _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ J CONFIGURATION ON FLAT GROUND PLAN VIEW OF PARCEL COMPACTED TOPSOIL OR OTHER CLEAN FILL NON -WOVEN GEOTEXTILE FOR SEPARATION 6" DIA. MIN, ON TOP AND SIDES OF TRENCH PER WSDOT PERFORATED PVC, SPECIFICATIONS SECTION 9-33.2(1) TABLE 3 SDR 35 PER ASTM D3034 SOLIDS/ LEAVES n o o \ \//�� � / \"�\\ . D FILTER SCREEN 18" MIN. \� V D 3/4" - 1 1/2" WASHED DRAIN ROCK OR GRAVEL BACKFILL D D DRYWELLS PER WSDOT STD. ZIO \ SPECIFICATION SECTION 9-03.12(5) GROUND \� D/� D D D D �24"MIN, UNDISTURBED NATIVE SOIL g TYPICAL DOWNSPOUT MIN. V ABOVE SEASONAL HIGH FILTER DETAIL GROUNDWATER TABLE SECTION A NOTES: 1. TRENCH LENGTH TO BE 10 FEET IN LENGTH FOR EVERY 5,000 SF OF CONTRIBUTING IMPERVIOUS SURFACE, OR 35,000 SF OF NON-NATIVE PERVIOUS SURFACE, OR PORTION THEREOF. GENERAL NOTES: 1. INFILTRATION TRENCHES LIMITED TO ROOF RUNOFF FROM SINGLE-FAMILY OR DUPLEX HOMES OR TO CONTROL BASEMENT FLOODING. CONSULT WA DEPARTMENT OF ECOLOGY REGULATIONS FOR UNDERGROUND INJECTION CONTROL PROGRAM (UIC) FOR OTHER TYPES OF RUNOFF MANAGEMENT. 2. IMPERVIOUS AREAS LARGER THAN 10,000 SF AND NON-NATIVE PERVIOUS AREAS LARGER THAN 35,000 SF MAY REQUIRE LARGER PIPE AND SHOULD BE DESIGNED BY A CIVIL ENGINEER. 3. THE PERFORATED PIPE MAY NOT BE PLACED IN A CRITICAL AREA BUFFER OR ON SLOPES STEEPER THAN 25%. 4. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 263.40 PUBLIC WORKS PERFORATED STUB -OUT APP R DEPARTMENT CONNECTION Martin Pastucha 11/2/2 bIFD98B449D... DATE Know what's below. Call before you dig. CITY 0E RENTON Planning/Building/Public Works Dept. DWG# R-421506 S-421502 W-421502 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CASTLE DEVELOPMENT TOWNHOMES AS -BUILT CONSTRUCTION DETAILS Z W 75 n O J W LU DATE: Q 09/29/2023 FIELDBOOK: `,I„ I PAGE: DRAWING NO: I- U) SHEET: OR DDCuSign Envelope TD: BEECF586-602A-4E4A-B436-A317AA638878 U-) Lo U-) N � ~ N N ^^, W U) SLu L O Z O I- I- Z 5W L In O J W > W W C^ I- / Q U 3 0 FRAME AND VANED GRATE 4", V. 12", OR 24' ONE 93 BAR HOOP FOR S" HEIGHT INCREMENT(SPACEO EQUALLY). SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION �8 t � ! Z I I M3 RAR EACH CORNER I� I 83 BAR EACH SIDE 7r 9 i138AR EACH WAY PRECAST BASE. SECTION 1$3 BAR HOOP 113 BAR EACH CORNER 18" PAIN. SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION • PUBLIC WORKS DEPARTM ENT PIPE ALLOWANCES mul Mum PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN 1 CONCRETE ALL METAL PIPE 15" CPsSP•. 1r STD. SPEC. 9A520 SOLID WALL PVC, STD. SPEC. &45.12(1 ) 16' PROrrLE WALL PVC, STD. SPEC. B-d5-12I2} 15" ' CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: 1 AS ACCEPTABLE OLLTER14ATIVES TO THE REBAR S"MNN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICA7IDN 9­35. Wgl ), OR WIFE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED RE6AR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION, WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 41.12 SQUARE INCHES PER FOOT MAY BE 0 9F 15 2. THE KNOCKOUT DIAMETER SNAIL NOT HE GREATER THAN 2p". KNOCKOUTS SHALL HAVE A WALA. THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.F MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR 1N ACCORDANCE WITH STANDARD SPECIFICATION 9 (W.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL HE 5 FEET. 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. 5. THE PRECAST SASE SECTIOTV MAY HAVE A ROUNDED FLOOR. AND THE WALLS MAY BE SLOPED AT A RATE OF 111:24Y Oft STEEPER. II, THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SEC NON- 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BE EN PLACED. USE GROUT TYPE 2 FOR NON$HR INK APPLICATIONS SN ACCORDANCE WITH STANDARD SPECIFICA-nON 9120 312). 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE W ITN STANDARD SPECIFICATION 9-04-3. THEN APPLY MORTAR TO INSIgE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AN11 FRAMES. 9. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAMEISFLDSH WITHPAVEMENTAS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 11. ALL MORTAR JOINTS SHALL HE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. 11NLE55 CIIWe IONISE NOTEo. HAWING iS NOT TQ SCALE INTSH STO. PLAN-200�00 Appit9tEll CATCH BASIN TYPE 1 GAZ 9/28/2018 r.u:.wa•��a"RATE MIN VARIES MIN � MIN MSN � 16L No 1 EN THE EVENT TRANSVERSE PATCHES EXIST I VATHIN THE AFFECTED STREET, THE LENGTH i I I OF THE PATCH SHALL BE EXTENDED TD II INCLUDE ANY EXISTING PATCH "THIN 10 FEET OF THE EDGE OF THE PATCH REQUIRED FOR THE NEW CROSSING AND ANY SUBSEOUENT PATCH EOGE WITHIN 10 FEET I OF THE EDGE OF THE SECOND PATCH AND i 44I SD ON UP TO A TOTAL OF 360 FEET I FACE OF GUTTER OR 1=DCE OF PAVEMENT TRAFFIC FLOW 2" HMA I I CENTER LJNE OR LANE LINE 2" TO B" HMA { I 8.5' MIN. 2" DEPTH OF PLANING OR SAWCUT AND REMOVE VARIES: 5.5 MIN. DEPTFI OF EXISTING PAVEMENT VARIES -'"� PIN I MIN MIN Miry 2' SAWCUT AND REMOVE W PLANE. SEAL WITH AFT-4DDDw F 2" - 6" MIN. HMA (SEE NOTE 2) \6" LEACH SIDE) I CRUSHED SURFACING TOP COURSC (CSTC) 2- HMA STANDARD ,SPECIFICATIONS, COMPACTED TO M904FIED PROCTOR, SAWCUT AFTER BACKFILL (EACH SIDE) CSiC, BANK RUN GRAVEL FOR TRENCH BACKFILL BORROWlPER GFCATIONS3GR [ WSOCTANDAROSPECIFICATIONS NA VE MATERIAL IF APPROVED IN WRITING BY ENGINEER BASED ON CEOTECH REPORT, COMPACTED TO 95X MODIFIED PROCTOR, WIDTH OF TRENCH AS REQUIRED BY SIZE OF PROPOSED IMPROVEMENT {SEE E FOR STANDARD SPEC SHORING. 2-09.4} PLUS D, ALLOWANCE FOR ANY SHORING, SHORING. IF PIPE ZONE BEDDING. MATERIAL- SEE STANDARD N£EDEO, SHALL MEET THE REQUIREMENTS OF WSDOT PLAN 1f0.1. 5TARDARD SPECIFICATION 7-M.3(1)8 TRENCH WMDTH FOR NOTES, SEE STANDARD PLAN 110_1 TYPICAL TRANSVERSE PATCH FOR STD. PLm - 110 PUBLIC WORKS DEPARTMENT PAVEMENT OR RIGId 'PR 'ED PAVEMENT WITH OVERLAY f�;.�,. ■ CASTLE DEVELOPMENT TOWNHOMES RECORD DRAWINGS SW 114 OF SE 114 OF SECTION 18, T. 23 N., R. 05 E., W.M. CITY OF RENTON, STATE OF WASHINGTON :45 A SL1 z l � LL � 0lo DIRECTION OF FLOW _ iZ ry 3" (MIN.} I 5" MIN. fi"MIN.(TYP.) UNION (TYP.) PLAN X < 3"MAX, Q � 5"MIN. I TO CITY METER STACKED METER SECTION" MIN. FREE BODES DRAINING GRAVEL NOTES: 1. ALL DOUBLE CHECK VALVE ASSEMBLIES (DCVA's) MUST BE LISTED ON LATEST LIST OF-BACKFLOW PREVENTION ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2, THE OWNER/APPLICANT MUST .OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE DCVA AND PIPING- THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE DCVA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE DCVA MUST BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE. A COPY OF THE TEST REPORT SHALL 8E SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT_ ATTN: WATER UTILITY CROSS -CONNECTION CONTROL SPECIALIST, FAX NO. 425-430-7241. 4. DCVA AND METER BOX SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER_ S4' TO 2" DOUBLE CHECK VALVE STD. PLAN - 340.8 * + PUBLIC WORKS ASSEMBLY FOR IRRIGATION OR DEPARDAENT RESIDENTIAL FIRE SPRINKLER MARCH 2010 pH I LIp S Gj`S,F OF WAS�tAld j ncom Er)ass � � ENGINEERING & SURVEYINGmm Western Washington Division 31B375 v 165 NE Juniper Street, Suite 201 - IssaQuah, WA 98027 - Phone: (425) 392-0250 1STER��S�'' Eastern Washington Division SIONAL 407 Swiftwater Blvd. ■ Cle Elum, WA 98922 ■ Phone: (509) 674-7433 0912012023 1 N 0. REVISION 6" PVC OVERFLOW TO SDCO 20' IE= 25.1 COMPACTED 6" PVC PERF PIPE 6" BACKFILL f WASHED DRAIN ROCK 4 "-1 2" NON -WOVEN GEO TEXTILE FOR SEPARATION ON TOP AND SIDES OF TRENCH PER WSDOT SPECIFICATIONS SECTION 9-33.2(1) TABLE 3 PER COR STD PLAN 225.20 SECTION B-B COMPACTED BACKFILL 6 1' 1' WASHED DRAIN ROCK 3"-1 2" NON -WOVEN GEOTEXTILE FOR SEPARATION ON TOP AND SIDES OF TRENCH PER WSDOT SPECIFICATIONS SECTION 9-33.2(1) TABLE 3 PER COR STD PLAN 225.20 6" PVC OVERFLOW TO SDCO IE= 24.7 6� 1' 1' 6 FG= 2 7. 0 IE= 25.0 I' ABOVE SEASONAL HIGH GROUND WATER - 6 " P VC SDR 35 PERF PIPE PER ASTM D3034 PER COR STD PLAN 225.20. TYP TO ALL PERF PIPE SECTION A -A 10' COMPACTED BACKFILL T777-_ WASHED DRAIN ROCK 4 '-1 2" NON -WOVEN GEOTEXTILE FOR SEPARATION ON TOP AND SIDES OF TRENCH PER WSDOT SPECIFICATIONS SECTION 9-33.2(1) TABLE 3 PER COR STD PLAN 225.20 6" PVC PERF PIPE SECTION B-B COMPACTED BACKFILL 1' o 1' WASHED DRAIN ROCK 4 "-1 2" NON -WOVEN GEO TEXTILE FOR SEPARATION ON TOP AND SIDES OF TRENCH PER WSDOT SPECIFICATIONS SECTION 9-33.2(1) TABLE 3 PER COR STD PLAN 225.20 SURVEYED: BUI DESIGNED: IWD DRAWN: TNF CHECKED: IWD BY DATE AP P R APPROVED: CID SCALE: YARD DRAIN PER COR STD PLAN 225.20 6" PVC OVERFLOW T- SDCO 4 LF 6" P� PERF PIPE 18LF6"PVC PERF PIPE WASHED ROCK 3/4" TO 1-112" YARD DRAIN PER C( STD PLAN 225.20 6'x20' INFILTRATION TRENCH YARD DRAIN PER COR STD PLAN 225.20 5 FG= 27.0 q IE= 24.6 �1 ' ABOVE SEASONAL HIGH GROUND WATER - 6" PVC SDR 35 PERF PIPE PER ASTM D3034 PER COR STD PLAN 225.20. TYP TO ALL PERF PIPE SECTION A -A ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M YARD DRAIN PER COR STD PLAN 225.20 WASHED ROCK 3/4 TO 1-112" 8LF6"PVC PERF PIPE 6" PVC OVERFLOW SDCO N 6" PVC SDR 35 FROM ROOF DRAIN/ DOWNSPOUT 6" PVC SDR 35 FROM ROOF DRAIN/ DOWNSPOUT -27 N 6" PVC PIPE It O O O I N ry �'N/ /Lo O O N N WA I•_J W O 5'xl2' INFILTRATION TRENCH = Z 1 "=5' DWG# R-421507, S-421503 W-421503 O IN COMPLIANCE WITH CITY OF RENTON STANDARDS Know what's below. Call before you dig. CITY OF RENTON [;R Planning/Building/Public Works Dept. CASTLE DEVELOPMENT TOWNHOMES AS -BUILT CONSTRUCTION DETAILS Z W 5 n O J Lu > DATE: W 0 09/29/2023 FIELDBOOK: u„ I PAGE: DRAWING NO: I- U) SHEET: 7 OF: 7