HomeMy WebLinkAboutCivil PlansDEVELOPMENT ENGINEERINGJChavez 04/21/2022
– – – – DRAWING INDEX NOTES, & ABBREVIATIONSNICNICNICNICNICBID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHIN
GTONLICENSEDLANDSCAPEARCHITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
DRAWING INDEXG.02 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421102
S 7TH STREET
(DEDICATED PUBLIC RIGHT-OF WAY)HIGHLAND ADDITION TO THETOWN OF RENTONVOL. 17 PG. 32BE
A
C
O
N
W
A
Y
S
(D
E
D
I
C
A
T
E
D
P
U
B
L
I
C
R
I
G
H
T
-
O
F
W
A
Y
)
H
E
R
I
T
A
G
E
R
E
N
T
O
N
H
I
L
L
V
O
L
.
2
1
1
P
G
.
3
4
S 7TH STREET
(DEDICATED PUBLIC RIGHT-OF WAY)
H
E
R
I
T
A
G
E
R
E
N
T
O
N
H
I
L
L
V
O
L
.
2
1
1
P
G
.
3
4
PHILLIP ARNOLD PARK
CITY OF RENTON
ADDRESS: 720 JONES AVENUE SOUTH
PCL. NO. 202305-9059JONES AVE S(DEDICATED PUBLIC RIGHT-OF WAY)BE
A
C
O
N
W
A
Y
S
(D
E
D
I
C
A
T
E
D
P
U
B
L
I
C
R
I
G
H
T
-
O
F
W
A
Y
)NE 1/4 SECTION 20, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M.NW 1/4 SECTION 20, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M.HORIZONTAL DATUM:
VERTICAL DATUM:HIGH AVE S(DEDICATED PUBLIC RIGHT-OF WAY)GRANT AVE S(DEDICATED PUBLIC RIGHT-OF WAY)RENTON AVE S(DEDICATED PUBLIC RIGHT-OF WAY)S 7TH STREET
(DEDICATED PUBLIC RIGHT-OF WAY)HIGHLAND ADDITION TO THETOWN OF RENTONVOL. 17 PG. 32HIGH AVE S(DEDICATED PUBLIC RIGHT-OF WAY)GRANT AVE S(DEDICATED PUBLIC RIGHT-OF WAY)S 9TH STREET
(DEDICATED PUBLIC RIGHT-OF WAY)98102-3513BUSH, ROED & HITCHINGS, INC.2009 MINOR AVE. EASTSEATTLE, WashingtonLAND SURVEYORS & CIVIL ENGINEERSFAX# (206) 323-7135(206) 323-41441-800-935-0508BOUNDARY AND TOPOGRAPHIC SURVEYHBB LANDSCAPE ARCHITECTUREPHILLIP ARNOLD PARKRENTONKING COUNTY WASHINGTON
NW & NE 1/4 SECTION 20, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M.
SHEET 3 OF 3
SHEET 1 OF 3
SHEET LAYOUT MAP
SEE SHEET 2 SEE SHEET 2
SHEET 2 OF 3
\\Brh02\cad\C3D\2019\2019230\SURVEYING\DWG\XS-SUR-00.dwg, 2/4/2020 12:52:14 PM, taylors, 1:1
H
E
R
I
T
A
G
E
R
E
N
T
O
N
H
I
L
L
V
O
L
.
2
1
1
P
G
.
3
4
PHILLIP ARNOLD PARK
CITY OF RENTON
ADDRESS: 720 JONES AVENUE SOUTH
PCL. NO. 202305-9059
BE
A
C
O
N
W
A
Y
S
(D
E
D
I
C
A
T
E
D
P
U
B
L
I
C
R
I
G
H
T
-
O
F
W
A
Y
)JONES AVE S(DEDICATED PUBLIC RIGHT-OF WAY)98102-3513BUSH, ROED & HITCHINGS, INC.2009 MINOR AVE. EASTSEATTLE, WashingtonLAND SURVEYORS & CIVIL ENGINEERSFAX# (206) 323-7135(206) 323-41441-800-935-0508BOUNDARY AND TOPOGRAPHIC SURVEYHBB LANDSCAPE ARCHITECTUREPHILLIP ARNOLD PARKRENTONKING COUNTY WASHINGTON
NW & NE 1/4 SECTION 20, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M.
SEE SHEET 1 SEE SHEET 1
SEE SHEET 3
\\Brh02\cad\C3D\2019\2019230\SURVEYING\DWG\XS-SUR-00.dwg, 2/4/2020 12:51:02 PM, taylors, 1:1
JONES AVE S(DEDICATED PUBLIC RIGHT-OF WAY)PHILLIP ARNOLD PARK
CITY OF RENTON
ADDRESS: 720 JONES AVENUE SOUTH
PCL. NO. 202305-9059
SUBSTRUCTURES:
TELECOMMUNICATIONS/FIBER OPTIC DISCLAIMER:
UTILITY PROVIDERS:
ZONING:
VERTICAL DATUM:98102-3513BUSH, ROED & HITCHINGS, INC.2009 MINOR AVE. EASTSEATTLE, WashingtonLAND SURVEYORS & CIVIL ENGINEERSFAX# (206) 323-7135(206) 323-41441-800-935-0508BOUNDARY AND TOPOGRAPHIC SURVEYHBB LANDSCAPE ARCHITECTUREPHILLIP ARNOLD PARKRENTONKING COUNTY WASHINGTON
NW & NE 1/4 SECTION 20, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M.
SEE SHEET 2 SEE SHEET 2
\\Brh02\cad\C3D\2019\2019230\SURVEYING\DWG\XS-SUR-00.dwg, 2/4/2020 12:50:32 PM, taylors, 1:1
CURRENT PLANNINGClark Close 04/21/2022
CURRENT PLANNINGClark Close 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
CURRENT PLANNINGClark Close 04/21/2022
CURRENT PLANNINGClark Close 04/21/2022
CURRENT PLANNINGClark Close 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
CURRENT PLANNING
Clark Close 04/21/2022
CURRENT PLANNING
Clark Close 04/21/2022
CURRENT PLANNING
Clark Close 04/21/2022
CURRENT PLANNING
Clark Close 04/21/2022
CURRENT PLANNING
Clark Close 04/21/2022
CURRENT PLANNING
Clark Close 04/21/2022
CURRENT PLANNING
Clark Close 04/21/2022
CURRENT PLANNING
Clark Close 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DEVELOPMENT ENGINEERING
JChavez 04/21/2022
DESCRIPTIONSYMBOL SYMBOL
LIGHTING
DESCRIPTION
REFERENCE SYMBOLS
DESCRIPTION
DIAGRAMS
SYMBOL
WIRING DIAGRAMS
SYMBOL / DESCRIPTION
1. GENERAL: WORK SHALL BE DONE IN ACCORDANCE WITH CODES
AS ADOPTED BY THE CITY OF RENTON, KING COUNTY, AND THE
STATE OF WASHINGTON.
2. WSDOT AND CITY OF RENTON (COR) STANDARDS APPLY TO, ANDARE MADE PART OF, THIS SCOPE OF WORK.
3. LOCATIONS OF ELECTRICAL EQUIPMENT, DEVICES, LIGHTING
FIXTURES, ETC., INDICATED ON CIVIL AND LANDSCAPE PLANS -
INCLUDING SECTIONS, ELEVATIONS, NOTES, OR OTHER
INDICATORS - TAKE PRECEDENCE OVER LOCATIONS SHOWN ON
ELECTRICAL DRAWINGS.
4. REFER TO CIVIL, STRUCTURAL, LANDSCAPE, ETC., DRAWINGS FORWORK IN OTHER DIVISIONS. INFORMATION CONVEYED WITHINTHE ELECTRICAL DRAWINGS ILLUSTRATING OR REFERENCING
WORK OF OTHER DIVISIONS IS FOR REFERENCE ONLY.
SPECIFICATION BY THE RELEVANT DIVISIONS SHALL APPLY.
5. GENERAL NOTES ARE SHOWN ON SHEETS MOST RELEVANT TO
SPECIFIC NOTE; HOWEVER, GENERAL NOTES ON EACH SHEET
SHALL APPLY IN PRACTICE TO ALL ELECTRICAL DRAWINGS.
6. NOT ALL COMPONENTS OF THE ELECTRICAL SYSTEMS ARESHOWN (FOR SIMPLICITY). PROVIDE MATERIALS AND LABORNECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM.
7. STAINLESS STEEL HARDWARE: MATERIALS USED FOR THE
MOUNTING AND SUPPORT OF BOXES CABLES, RACEWAYS, LIGHT
FIXTURES, OUTLETS, AND OTHER ELECTRICAL EQUIPMENT, SHALL
BE 316 STAINLESS STEEL. THIS REQUIREMENT APPLIES TO THE
AFOREMENTIONED COMPONENTS WHEN INSTALLED OUTSIDEABOVE GRADE.
8. LOCATIONS OF ELECTRICAL SYSTEMS COMPONENTS, INCLUDINGBUT NOT LIMITED TO, LUMINAIRES, DISTRIBUTION EQUIPMENT,
CONDUIT, JUNCTION BOXES, VAULTS, ETC., MAY BE REVISED
PRIOR TO CONSTRUCTION. CHANGES MADE BY THE OWNER IN
LOCATING ELECTRICAL COMPONENTS OF UP TO THIRTY FEET
HORIZONTALLY (AND/OR VERTICALLY) IS A PART OF THIS
CONTRACT. CHANGES IN LOCATION MAY BE IMPLEMENTED, ATNO CHARGE TO THE OWNER, WHEN MADE PRIOR TO ROUGH-IN OFEQUIPMENT BEING RELOCATED.
9. COORDINATE LOCATIONS OF ELECTRICAL AND COMMUNICATION
CHASES AND CONDUITS WITH OTHER TRADES. ADJUST
LOCATIONS AS NECESSARY TO AVOID CONFLICTS.
10. CONDUCTORS SHALL BE LABELED IN JUNCTION BOXES AND AT
TERMINATIONS.
11. SCOPE OF WORK: THE SCOPE OF WORK FOR THIS PROJECT
INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING:
A. PERMITS: GIVE ALL NECESSARY NOTICES, OBTAIN ALLPERMITS AND PAY ALL GOVERNMENT TAXES, FEES ANDOTHER COSTS IN CONNECTION WITH THIS WORK. OBTAIN
ALL REQUIRED CERTIFICATES OF INSPECTION OF THE
WORK AND DELIVER SAME TO THE ENGINEER AT THE TIME
OF SUBSTANTIAL COMPLETION AND BEFORE REQUEST FOR
FINAL PAYMENT.
B. POWER OUTAGES: POWER OUTAGES SHALL BE LIMITED TO
THE HOURS OF 6:00PM TO 7:00AM WEEKDAYS. OUTAGESSHALL BE REQUESTED IN WRITING TO THE OWNER 7-DAYSPRIOR TO THE DESIRED DATE AND TIME. NO OUTAGE SHALLOCCUR WITHOUT THE PRIOR APPROVAL OF THE OWNERS
REPRESENTATIVE. OUTAGES SHALL NOT EXCEED (8)
CONSECUTIVE HOURS.
C. TEMPORARY POWER: PROVIDE TEMPORARY POWER AS
NEEDED BY ALL TRADES DURING THE EXECUTION OF THIS
CONTRACT.
* NOT ALL SYMBOLS LISTED ARE USED.
SYMBOL
LIGHTING - EXISTING
DESCRIPTION
SITE ELECTRICAL
SYMBOL DESCRIPTION
SITE ELECTRICAL EQUIPMENT - EXISTING
SYMBOL DESCRIPTION
PROJECT NOTES ELECTRICAL LEGEND*
ABBREVIATIONS
DEPTH
RECESS
REMARKSVOLTS CATALOG NUMBERWATTSLAMP TYPE
TOTAL
TYPE QTY.
LAMP IMFORMATION
MANUFACTURERSIZE / DESCRIPTIONTYPE MOUNTING
S0
S25
-1204000K LEDLED1 KIM LIGHTINGIN-GRADE LED SIGN LIGHT 9.6
-1204000K LEDLED 1
-120LED 1POLE MOUNTED LUMINAIRE 101
LTV767NF/6L4K120/RG60 IN-GRADE INSTALL IN CONCRETE FOOTING. STEPPED
DIMMABLE DRIVER TO 50%..
4000K LED LUMEC PROVIDE FIXTURE WITH NIXALITE BIRD DETERRENT
SPIKES; EPOXY FASTENED PRIOR TO INSTALLATION.
PROVIDE POLE WITH POLE BASE RECEPTACLE WITH
LOCKABLE METAL CAST COVER.
LUMINAIRE:
PBDP103-101W128LED4K-MP
-PC-C-LE5-UNV-DMG-N-BKSTPOLE: HUBBELL RTA-CO7N5-02525-FT TAPERED AL (4X7")
CONC.
BASE
SHELTERPRIMUSS10 LINEAR CANOPY LIGHT EL2-FRL-LED-M-40K-UNV-
EF-C-4'
73 COORDINATE MOUNTING WITH SHELTER
FABRICATOR. MOUNTING HARDWARE,CONDUIT, AND BOXES, SHALL BE PAINTED
TO MATCH SHELTER FINISH.
S3 -24VDC4000K LEDLED1 KLIK SYSTEMSHANDRAIL MOUNTED LED 1.9 LEDPOD 40 ASYMMETRICAL INSIDEHANDRAIL PROVIDE 120-24V REMOTEDRIVERS/POWER SUPPLY SIZED FOR
FIXTURE QUANTITIES AND RATED FOR
WET LOCATIONS.
LIGHTING FIXTURE SCHEDULE
BID SET
PHILIP ARNOLD PARK
PM: ED DAVID, PE TEL: 206.855.4600
04/01/22
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SYMBOLS AND
ABBREVIATIONSTED-04-4211R-421155E0.00 PHILIP ARNOLD PARKPHILIP ARNOLD PARKPR:LUA: C: C21006142
COPPER FEEDER SCHEDULE
FEEDER SCHEDULE NOTES:
kW
50/2
200/2
PAD MTD.UTILITY CO. XFMR
20/1 20/1
TO POLE
MOUNTED
LIGHTS
(TYPE S25)
G
20/1 20/1
TO SIGNLIGHTS(TYPE S0)
TO RECEPT. INTYPE 'S25'LIGHTS
PANEL 'SPL'200A - 120/240V, 1P, 3W, 22kAICSERVICE ENTRANCE RATED
G G
PC
50/2 20/1
SPARE
PEDESTAL
PP-2A
PEDESTAL
PP-2B
20/1
TO SHELTER
LIGHTS
(TYPE S10)
30/2
PEDESTALPP-3
20/1
BOOSTER
PUMP; 1/2HP,
240V, 1Ø.
20/1-GFCI
15/2
20/1
SPARE
15/1
SPARE
20/1
GG
GFCI
RECEPT
TO PORTLANDLOO RECEPT.
20/1
GFCI
RECEPTS
TO HANDRAIL
LIGHTS
(TYPE S3)
G G
kW
PAD MTD.UTILITY CO. XFMR
IRRIGATION
PUMP; 10HP,
480V, 3Ø.
60/3
30/3 20/1
VFD
PANEL 'SPH'100A - 480/277V,3P, 4W, 22kAICSERVICE
ENTRANCE
RATED
TO IRRIGATION
CONTROLLER
IN 'SPL'
G
SPACE20/1
SPARE
GFCIRECEPT
BID SET
PHILIP ARNOLD PARK
PM: ED DAVID, PE TEL: 206.855.4600
04/01/22
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SCHEDULES AND
DIAGRAMS
SINGLE LINE WIRING DIAGRAM
GENERAL NOTES
SHEET NOTES
R-42115TED-04-4211R-421156E1.00 PHILIP ARNOLD PARKPHILIP ARNOLD PARKPR:LUA: C: C21006142
S 7TH STREET
JONES AVE SBE
A
C
O
N
W
A
Y
S
BID SET
PHILIP ARNOLD PARK
PM: ED DAVID, PE TEL: 206.855.4600
04/01/22
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
ELECTRICAL
PLAN - NORTH
GENERAL NOTES
SHEET NOTES
ELECTRICAL PLAN - NORTH
TYPE 'S0' DETAIL
PEDESTAL PP-2
R-42115TED-04-4211R-421157E2.01 PHILIP ARNOLD PARKPHILIP ARNOLD PARKPR:LUA: C: C21006142
BE
A
C
O
N
W
A
Y
SJONES AVE SS 9TH STREET
BID SET
PHILIP ARNOLD PARK
PM: ED DAVID, PE TEL: 206.855.4600
04/01/22
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
ELECTRICAL
PLAN - CENTER
GENERAL NOTES
SHEET NOTES
ELECTRICAL PLAN - CENTERTED-04-4211R-421158E2.02 PHILIP ARNOLD PARKPHILIP ARNOLD PARKPR:LUA: C: C21006142
JONES AVE SBID SET
PHILIP ARNOLD PARK
PM: ED DAVID, PE TEL: 206.855.4600
04/01/22
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
ELECTRICAL
PLAN - SOUTH
GENERAL NOTES SHEET NOTES
ELECTRICAL PLAN - SOUTH
ELECTRICAL PLAN - SOUTH
R-42115TED-04-4211R-421159E2.03 PHILIP ARNOLD PARKPHILIP ARNOLD PARKPR:LUA: C: C21006142
A
B
MANUAL WATERING
BY SENSORSUSPENDEDWATERING
OFFSENSORACTIVE
ONOFFPGMADV.STARTMAN-
STATUSSTATION MAXICOMLINKED TO DAY CYCLECYCLICALODD DAYCYCLE STATUSPUMP / MVEVEN DAYCYCLEDAY CYCLECUSTOM
OFF
TEST PROGRAMCYCLE + SOAKWATERBUDGETEVEN DAYSODD DAYSCYCLICALCUSTOM SUNSATFRITHUWEDTUEMON
STATION WATERING TIMEWATERING START TIMEMY PUMP STARTPROGRAM OVERLAPTIMECALENDAREVENT DAY OFFRAIN DELAY
AUTO
B
A
3"A
FINISHED GRADE
DUCT SCHEDULE
1 STRONGBOX ENCLOSURE #SB24-SS-120V
ALUMINUM PANEL (BOLTED TO BACK WALL OF BOX)
HYBRID CONTROLLER: SEE LANDSCAPE DRAWINGS ANDSPECIFICATIONS.
TERMINAL BOX WITH TERMINAL STRIPS.
FLOW MONITOR.
PUMP MFGR: SEE LI SERIES SHEETS FOR (E) IR. PUMP.
LEVITON 5280-W, GFI OUTLET.
12" ENCLOSURE EXTENSION (TYP.)
PRE-CAST OR CONCRETE BASE
1. STRONG BOX CABINET - #SB-24SS-120V.
2. COLD ROLLED STEEL CONSTRUCTION
3. POWDER COATED DARK GREEN COLOR
4. TWO LOUVERED VENTS ON EACH SIDE
5. REMOVABLE EQUIPMENT MOUNTING PANELS
6. CABINET BOLTED TO A PREFABRICATED CONCRETE BASE
7. HINGED METER VIEWING WINDOW WITH REINFORCED GLASS
8. CONTROL CABINET, PREFABRICATED CONCRETE BASE, IRRIGATIONCONTROLLER, TERMINAL STRIPS, SURGE PROTECTION, & PANEL
ASSEMBLY AVAILABLE FROM UNITED PIPE AND SUPPLY (MODEL #
IT-ICC-SBMC12MB-RP).
IRRIGATION CONTROL PANEL LEGEND:
ENCLOSURE CABINET & PANEL NOTES:
200 AMP METER BASE REQUIRED BY PUGET SOUND ENERGY(ALIGN METER WITH WINDOW TYP.)
PANEL 'SPL', 200A, 240/120V, 1Ø, 3W. 16-CIRCUIT; CIRCUIT
BREAKERS PER PANEL SCHEDULE. CONNECT PER SINGLE LINE
DIAGRAM.
LIGHTING CONTROLLER; DOUGLAS LITEPAK 2 #DLP2-8R8D-SM.
DATAREMOTE DIGITAL CELLULAR COMMUNICATION
UNIT WITH DOMED TOP ANTENNA & CABLE
MIN. 2" CONDUIT FOR STATION CONTROL WIRES
GROUND WIRE CONNECTS FROM GROUND LUGTO GROUNDING BUSS IN CONTROLLER (TYP.)
GROUND LUG (RUN WIRE FROM GROUND LUG TOGROUNDING ROD GRID TYP.)
METER / LOAD CENTER PANEL LEGEND:
2
3
4
5
6
7
8
A
B
9
10
11
12
16
17
13
18
BID SET
PHILIP ARNOLD PARK
PM: ED DAVID, PE TEL: 206.855.4600
04/01/22
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SCHEDULES AND
DIAGRAMS
SERVICE/IRRIGATION CONTROL PEDESTAL
POLE BASE DETAIL HANDHOLE DETAIL
TYPICAL DUCT BANK
R-4211TED-04-4211R-421160E3.00 PHILIP ARNOLD PARKPHILIP ARNOLD PARKPR:LUA: C: C21006142
SITE FURNISHINGS SCHEDULEABBREVIATIONSNOTESBBLEGENDBID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FURNISHINGS SCHEDULE,NOTES, ABBREVIATIONS, & LEGENDLS.00 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421161CURRENT PLANNINGClark Close 04/21/2022
CONCRETE MOW STRIPCOORDINATE CHART123BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS PLAN - NORTHSCALE: 1" = 8'-0"SIGN AREA ENLARGEMENT1LS.01 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421162CURRENT PLANNINGClark Close 04/21/2022
BBBBBBBBBBBBBB594678101112CONCRETE MOW STRIPCOORDINATE CHARTBID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS PLAN - CENTRALLS.02 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421163CURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS PLAN - SOUTHLS.03 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421164CURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSSCALE: 1" = 8'-0"LARGE SHELTER & RESTROOM AREA ENLARGEMENT1SCALE: 1" = 8'-0"LARGE SHELTER & RESTROOM AREA LAYOUT2LS.04 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421165CURRENT PLANNINGClark Close 04/21/2022
ALTERNATE 2:ALTERNATE 2:ALTERNATE 2: ALTERNATE 2:BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSSCALE: 1" = 8'-0"SMALL SHELTER AREA LAYOUTSMALL SHELTER AREA ENLARGEMENT21SCALE: 1" = 8'-0" LS.05 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421166NICCURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSSCALE: 1" = 5'-0"WEST PARKING LOT ENTRANCE ENLARGEMENT1LS.06 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA: NOT TO SCALE2EXISTING WOOD BARRICADE R-421167CURRENT PLANNINGClark Close 04/21/2022
BBBBBBBID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSSCALE: 1" = 5'-0"BENCH AREA ENLARGEMENT1LS.07 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421168CURRENT PLANNINGClark Close 04/21/2022
159234678101112131432332223242526272930312818212016191517STAIR COORDINATECHARTCONCRETE MOW STRIPCOORDINATE CHARTBID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHIN
GTONLICENSEDLANDSCAPEARCHITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSSCALE: 1" = 5'-0"STAIR ENLARGEMENT PLAN (FOR ALTERNATE 1 SEE 1/LS.08B)1LS.08A PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421169NICCURRENT PLANNINGClark Close 04/21/2022
BBBB3536373839414240CONCRETE MOW STRIPCOORDINATE CHARTBID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILS ALTERNATE 1SCALE: 1" = 5'-0"SCRAMBLE PLAN - ALTERNATE 11LS.08B PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421170NIC
SCRAMBLE KEYBID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILS ALTERNATE 1LS.09 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA: NOT TO SCALE1SCRAMBLE KEY AXON- EASTNOT TO SCALE2SCRAMBLE KEY AXON- WEST R-421171NOT TO SCALE3OPENING TREATMENTSNIC
B1/C1B2/C2B3B4A1A2C3B5C4A3CO1A4B6CO2BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILS ALTERNATE 1LS.10 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA: NOT TO SCALE1UNIT MASONRY BLOCKS R-421172NIC
D1D3D2E1E3E2SA1SB1SB2SC1SD1SD2SE1SF1SF2BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILS ALTERNATE 1LS.11 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA: NOT TO SCALE1UNIT MASONRY BLOCKS R-421173NIC
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILS ALTERNATE 1LS.12 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA: NOT TO SCALE1SECTION ANOT TO SCALE2SECTION BNOT TO SCALE3SECTION CNOT TO SCALE4SECTION D R-421174NIC
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILS ALTERNATE 1LS.13 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA: NOT TO SCALE1SCRAMBLE SECTIONNOT TO SCALE2SIDE SECTION OF SCRAMBLE AT PLANTINGNOT TO SCALE3SCRAMBLE AT HANDRAILNOT TO SCALE4TOP OF SCRAMBLE WALL AT PLANTINGNOT TO SCALE5SCRAMBLE FACE ELEVATION R-421175NIC
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARCHITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSLS.14 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA: NOT TO SCALE1BOARDWALK ELEVATIONNOT TO SCALE3BOARDWALK R-421176NOT TO SCALE2BOARDWALK ENLARGEMENTCURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARCHITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSLS.15 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA: NOT TO SCALE2BOARDWALK AND GUARDRAIL SECTIONNOT TO SCALE4GUARDRAILNOT TO SCALE6POST ATTACHMENTNOT TO SCALE7BARRIER ATTACHMENTNOT TO SCALE1BOARDWALK AND CURB SECTIONNOT TO SCALE3BOARDWALK TRANSITIONNOT TO SCALE5BOTTOM BASE PLATE R-421177CURRENT PLANNINGClark Close 04/21/2022
720 Jones Ave SCITY OFRENTONPHILIP ARNOLD PARKPHILIP ARNOLD PARK720 Jones Ave SCITY OFRENTONBID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSLS.16 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA: NOT TO SCALE2ANCHOR BOLT CONNECTIONNOT TO SCALE1PARK ENTRY SIGN R-421178CURRENT PLANNINGClark Close 04/21/2022
PLAYGROUNDRESTROOMTENNIS COURTPICNIC AREABALLFIELDRESTROOMSTENNIS COURTBASKETBALLPLAYGROUNDRESTROOMSTENNIS COURTPICNIC SHELTERBALLFIELDRESTROOMSTENNIS COURTBASKETBALLPLAYGROUNDRESTROOMSTENNIS COURTPICNIC SHELTERBID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSLS.17 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA: NOT TO SCALE1WAYFINDING SIGN R-421179CURRENT PLANNINGClark Close 04/21/2022
WELCOMEPHILIP ARNOLD PARKDAWN TO DUSKHOURS OF OPERATION:(EXCEPT FOR SCHEDULED ACTIVITIES)THE FOLLOWING RULES ARE ENFORCEDWHEN USING THIS PARK:Use trash receptaclesRMC 2-9-8For more information visit Community ServicesCall 911 to report unwanted behaviorCITY OFRENTONPets shall be on a leash at all timesDismount bikes, scooters and skating devicesLoudspeakers and/or amplification of sound areprohibitedWeapons/fireworks are prohibited, except whenpermitted by lawCamping and overnight stays in the park are prohibitedGroup rally or group events require a special use permitUnlawful to vandalize or destroy any park equipment orstructuresSelling, handouts, soliciting or posting signs are notallowedNon-emergency calls: (425) 235-2121Department at Rentonwa.gov or (425) 430-6600BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSLS.18 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA: NOT TO SCALE1PARK RULES SIGN R-421180CURRENT PLANNINGClark Close 04/21/2022
MILE LOOPTHE QUARTERMILE LOOPTHE QUARTER/16MILE100m1BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSLS.19 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA: NOT TO SCALE1BRONZE TRAIL MARKER R-421181CURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSNOT TO SCALE1PARK GRILL & COAL ASH BINNOT TO SCALE5PICNIC TABLENOT TO SCALE4WASTE RECEPTACLENOT TO SCALE2BICYCLE RACKNOT TO SCALE3ANCHOR BOLTLS.20 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421182CURRENT PLANNINGClark Close 04/21/2022
BBBBBID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSNOT TO SCALE3PLAY AREA CONCRETE CURBNOT TO SCALE1BENCH WITH BACKNOT TO SCALE2BACKLESS BENCHNOT TO SCALE6PLAY AREA ENHANCED EDGENOT TO SCALE5BENCH NODE B LAYOUTNOT TO SCALE4BENCH NODE A LAYOUTLS.21 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421183CURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSNOT TO SCALE1BASKETBALL COURT STRIPING LAYOUTNOT TO SCALE2BASKETBALL GOALNOT TO SCALE3BOLLARDNOT TO SCALE4REMOVABLE BOLLARD WITH RECEIVERNOT TO SCALE5PICNIC SHELTER COLUMNLS.22 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421184CURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSNOT TO SCALE1STAIRS WITH HANDRAILLS.23 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA: NOT TO SCALE3HANDRAIL EMBED MOUNTWITH CONDUITNOT TO SCALE2HANDRAIL EMBED MOUNTNOT TO SCALE4RAMP AND HANDRAIL R-421185CURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSNOT TO SCALE1STANDING WALL ANOT TO SCALE2RETAINING WALL BNOT TO SCALE3RETAINING WALL CLS.24 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421186CURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSNOT TO SCALE4CONCRETE MOW STRIPNOT TO SCALE2SAWCUT CONTROL JOINTNOT TO SCALE3DRINKING FOUNTAINNOT TO SCALE1EXPANSION JOINT WITH DOWELLS.25 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421187CURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSNOT TO SCALE10PEDESTAL PLAN BNOT TO SCALE9PEDESTAL PLAN ANOT TO SCALE1J-BOX ANOT TO SCALE6POLE & J-BOX ANOT TO SCALE7PLAZA POLE & J-BOXNOT TO SCALE2J-BOX BLS.26 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA: NOT TO SCALE3J-BOX C: ALTERNATE 1NOT TO SCALE4J-BOX D: ALTERNATE 1NOT TO SCALE5J-BOX ENOT TO SCALE8POLE & J-BOX B R-421188NICNICCURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
SITE FINISHES & FURNISHINGS DETAILSLS.27 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421189NOT TO SCALE1STAIRS WITH CHEEK WALLNOT TO SCALE2CHEEK WALL TRANSITIONCURRENT PLANNINGClark Close 04/21/2022
PLANTING SCHEDULEPLANTING ABBREVIATIONSPLANTING NOTESPLANTING LEGEND®‘’ /PLANTING SCHEDULEPLANTING ABBREVIATIONSPLANTING NOTESPLANTING LEGEND®‘’ /PLANTING SCHEDULEPLANTING ABBREVIATIONSPLANTING NOTESPLANTING LEGEND®‘’ /PLANTING SCHEDULEPLANTING ABBREVIATIONSPLANTING NOTESPLANTING LEGEND®‘’ /PLANTING SCHEDULEPLANTING ABBREVIATIONSPLANTING NOTESPLANTING LEGEND®‘’ /BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
PLANTING SCHEDULE, NOTES,ABBREVIATIONS, & LEGENDLP.00 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
LP.00 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421190NICCURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
PLANTING PLAN - NORTHLP.01 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421191CURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
PLANTING PLAN - CENTRALLP.02 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421192NICCURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
PLANTING PLAN - SOUTHLP.03 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421193CURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
PLANTING ENLARGEMENTSSCALE: 1" = 5'-0"PLANTING ENLARGEMENT 11LP.04 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421194SCALE: 1" = 5'-0"PLANTING ENLARGEMENT 22CURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
PLANTING ENLARGEMENTSLP.05 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421195SCALE: 1" = 5'-0"PLANTING ENLARGEMENT 3SCALE: 1" = 5'-0"PLANTING ENLARGEMENT 421CURRENT PLANNINGClark Close 04/21/2022
ALTERNATE 1: PLANTING SCHEDULEALTERNATE 1: PLANTING SCHEDULEALTERNATE 1: PLANTING SCHEDULEALTERNATE 1: PLANTING SCHEDULEALTERNATE 1: PLANTING SCHEDULEBID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
PLANTING ENLARGEMENTSSCALE: 1" = 5'-0"PLANTING ENLARGEMENT 1 - ALTERNATE 11LP.06 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421196SCALE: 1" = 5'-0"PLANTING ENLARGEMENT 2 - ALTERNATE 12NIC
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
PLANTING DETAILSNOT TO SCALE1SOIL PREPARATION IN SOD LAWN AREASNOT TO SCALE2SOIL PREPARATION IN SHRUB & GROUNDCOVER AREASLP.07 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:C:NOT TO SCALE3SOIL PREPARATION IN RESTORATION LAWN AREAS R-421197CURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
PLANTING DETAILSNOT TO SCALE1SHRUB & GROUNDCOVER PLANTINGNOT TO SCALE2SHRUB & GROUNDCOVER PLANTING ON A SLOPENOT TO SCALE3SOIL PREP AT PAVING EDGENOT TO SCALE4GROUNDCOVER PLANTING LAYOUTLP.08 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421198CURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
PLANTING DETAILSNOT TO SCALE1DECIDUOUS TREE PLANTINGNOT TO SCALE3CONIFER TREE PLANTINGNOT TO SCALE4CONIFER TREE PLANTING ON A SLOPENOT TO SCALE2DECIDUOUS TREE PLANTING ON A SLOPELP.09 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-421199CURRENT PLANNINGClark Close 04/21/2022
IRRIGATION NOTESIRRIGATION SCHEDULEPIPE SIZE LEGENDIRRIGATION ABBREVIATIONSIRRIGATION LEGENDBID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
IRRIGATION SCHEDULE, PIPE SIZE LEGEND,IRRIGATION LEGEND, NOTES, & ABBREVIATIONSLI.00 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-4211100CURRENT PLANNINGClark Close 04/21/2022
S 7TH STREET(DEDICATED PUBLIC RIGHT-OF WAY)JONES AVE S(DEDICATED PUBLIC RIGHT-OF WAY)BEACON WAY S(DEDICATED PUBLIC RIGHT-OF WAY)BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
IRRIGATION PLAN - NORTH ANDIRRIGATION ALTERNATE 1LI.01 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-4211101NOT TO SCALE1IRRIGATION - ALTERNATE 1NICNICCURRENT PLANNINGClark Close 04/21/2022
BEACON WAY S(DEDICATED PUBLIC RIGHT-OF WAY)JONES AVE S(DEDICATED PUBLIC RIGHT-OF WAY)S 9TH STREET(DEDICATED PUBLIC RIGHT-OF WAY)BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
IRRIGATION PLAN - CENTRALLI.02 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-4211102NICNICCURRENT PLANNINGClark Close 04/21/2022
S 9TH STREET(DEDICATED PUBLIC RIGHT-OF WAY)JONES AVE S(DEDICATED PUBLIC RIGHT-OF WAY)BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
IRRIGATION PLAN - SOUTHLI.03 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-4211103CURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
IRRIGATION DETAILSNOT TO SCALE4FLOW SENSOR AND MASTER CONTROL VALVENOT TO SCALE3MAIN AND LATERAL PIPE TRENCHNOT TO SCALE5MANUAL BALL VALVENOT TO SCALE1POINT OF CONNECTIONNOT TO SCALE2AUTOMATIC CONTROL VALVE WITH BALL VALVENOT TO SCALE6POP-UP SPRAY OR ROTOR HEAD WITHTRIPLE SWING JOINT RISERLI.04 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA:
R-4211104CURRENT PLANNINGClark Close 04/21/2022
BID SETPHILIP ARNOLD PARKIN COMPLIANCE WITH CITY OF RENTON STANDARDS2101 4TH AVENUE, SUITE 1800 SEATTLE, WA 98121206.682.3051 phone206.682.3245 faxSTATEOFWASHING
TONLICENSEDLANDSCAPEARC
HITECT MERIT OVIIRNO. 1396 EXP.03/2023
C: C21006142
TED-04-4211
IRRIGATION DETAILSNOT TO SCALE1MANUAL DRAIN VALVENOT TO SCALE2PIPE SLEEVE UNDER PAVEMENTNOT TO SCALE4ROOT WATERING SYSTEMNOT TO SCALE5QUICK COUPLING VALVELI.05 PHILIP ARNOLD PARK
PHILIP ARNOLD PARK PR:LUA: NOT TO SCALE3LIGHTNING ARRESTERNOT TO SCALE6THRUST BLOCKING R-4211105CURRENT PLANNINGClark Close 04/21/2022