Loading...
HomeMy WebLinkAboutMFP22002150.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP22002150 IVR Number: 22002150 Permit Information Permit Name: JB0000897826 - OSP DE KV19 - Cutover Address/Location:04/22/2022Application Date:1432900280Parcel Number: 12801 SE 164TH ST Permit Type:09/13/2022Issue Date:Franchise Permit Work Class:09/13/2023Expiration Date:Minor Utility Job Number: JB0000897826Franchise Type:Cable Description: Comcast proposes to replace equipment at aerial location 21; Replace equipment at EG location;14. RESTORATION PER CITY OF RENTON STANDARDS. Contacts Name Address PhoneTypeBilling Ashley Kiehn 4610 Tacoma Avenue Sumner, WA 98390 ApplicantX Rhonda Resnik Comcast 410 Valley Ave NW, Suite 12, Bldg C Puyallup, WA 98371 B: (253) 864-4246Applicant Carissa Morris Sefnco Communications Applicant Tom Donnelly Comcast Business Communications 1701 Jfk Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact Sandra Castro Comcast C: (209) 561-4786Contact Scott Nall SEFNCO Communications Inc 2904 4th Ave NE Puyallup, WA 98372 B: (877) 385-2903 C: (253) 444-9057 Contractor Business License Number: 41108Construction Contractor: SEFNCCI850QD CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 3/18/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 3/18/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐ Electronic Copy of the TCP Application ☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: ▪ Include map(s) showing the location of the project and work area. ▪ Be legible lettering and clear, contrasting, symbols of viewing or printing. ▪ Must indicate street names, and north arrow and scale. ▪ Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering SEFNCO Communications 4610 Tacoma Ave Sumner, WA 98390 9:00am 3:30pm JB0000897826 - OSP DE KV19 - CUTOVER 12801 SE 164TH ST Carissa Morris (253) 313-2057 Comcast proposes to replace equipment at aerial location; 21. replace equipment at underground location; 14. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 3/18/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: • Must have approved Traffic Control Plan (TCP) prior to commencing the work. • Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. • WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • All permit conditions shall be met. NOTES: • Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. • Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. • In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 3/18/2021 • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) 04/22/2022 Linnea Bragg R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WSE 161ST STSE 161ST STSE 161ST STSE 161ST ST126TH PL SE 126TH PL SEFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSW SW SWSWSWSW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW POLEA1263012636TCP-1NREVISIONSDATEDESCRIPTIONINITIALTEMPORARY TRAFFICCONTROL PLANTRAFFIC CONTROL PLAN-131CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808401Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/2022FLAGGERFLAGGERFLAGGERLIMITSPEEDR2-125C B A ROADWORKAHEADONELANEROADAHEADLIMIT SPEED R2-1 25CBA ROADWORKAHEAD ONELANEROADAHEADLIMITSPEEDR2-125CBAROADWORKAHEADONELANEROADAHEADFLAGGER SETUP TYPICAL FORWORK IN ROW Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/WR/WR/WR/W R/W R/W R/W R/W 126TH PL SE126TH AVE SEFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCSWSW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SWSWSW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SWPOLEM1612716121TCP-2NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-231CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808402Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/202235'23'L IM IT SPE ED R2 -125AROADWORKAHEAD LIMITSPEEDR2-125AROADWORKAHEADSPOTTERNOPARKINGFROMTOTOW-AWAY A REA RCW 46 55 1 13NOTE:ADJACENT BUSINESSES AND/ORRESIDENT'S WILL BE NOTIFIED INWRITING 48 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS. Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE 162ND ST126TH PL SEFOCFOCFOCFOC FOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SWSWSWSW SW FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SWSWSWSWSW SWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SWSWSWSWSW POLEM1264712643TCP-3NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-331CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808403Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/202227'FLAGGERFLAGGERSPOTTERLIMIT SPEED R2-1 25CBA ROADWORKAHEAD ONELANEROADAHEADLIMITSPEEDR2-125CBAROADWORKAHEADONELANEROADAHEAD Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE 161ST STSE 161ST ST128TH AVE SE FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW MPPOLEM12690128001281712825TCP-4TCP-5128TH PL SE NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-431CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808404Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/202226'FLAGGERFLAGGERFLAGGERLIMITSPEEDR2-125C B A ROADWORKAHEADONELANEROADAHEADLIMITSPEEDR2-125CBAROADWORKAHEADONELANEROADAHEADLIMIT SPEED R2-1 25CBA ROADWORKAHEAD ONELANEROADAHEAD Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/W R/W R/WR/WR/WR/W R/WR/WR/WR/WR/WR/WSE 161ST STSE 161ST ST128TH AVE SEFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWS W SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW MPPOLEM126901280012817128251281412808TCP-4TCP-5128TH PL SE NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-531CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808405Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/202226'FLAGGERFLAGGERFLAGGERLIMITSPEEDR2-125CBA ROADWORKAHEADONELANEROADAHEADLIMIT SPEED R2-1 25CBA ROADWORKAHEAD ONELANEROADAHEADLIMITSPEEDR2-125CBAROADWORKAHEADONELANEROADAHEAD Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/WR/W126TH AVE SE 127TH AVE SESE 164TH STSE 164TH STFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC SWSW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOCFOCFOCFOC FOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWS W SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWPOLE1630216308MTCP-6NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-631CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808406Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/202235'SPOTTER22'LIMITSPEEDR2-125A ROADWORKAHEADLIMITSPEEDR2-125A ROADWORKAHEAD Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE 163RD STSE 163RD ST127TH AVE SEFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWPOLEM1270412712TCP-7NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-731CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808407Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/202226'FLAGGERFLAGGERLIMITSPEEDR2-125C B AROADWORKAHEADONELANEROADAHEAD LIMIT SPEED R2-1 25CBA ROADWORKAHEAD ONELANEROADAHEAD Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W127TH AVE SE 127TH PL SESE 164TH STSE 164TH STSE 164TH STSE 164TH STFOCFOCFOC FOC FOC FOC FOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCSWSWSW SW SW SW SW SWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWTPOLEM1271512723TCP-8NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-831CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808408Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/2022SPOTTERLIMIT SPEED R2-1 25AROADWORKAHEADLIMITSPEEDR2-125A ROADWORKAHEADLIMITSPEEDR2-125AROADWORKAHEAD26'36'NOTE:ADJACENT BUSINESSES AND/ORRESIDENT'S WILL BE NOTIFIED INWRITING 48 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.NOPARKINGFROMTOTOW- AWA Y AR EA R CW 4 6 55 11 3 Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W 128TH AVE SE 127TH PL SESE 164TH STSE 164TH STSE 164TH STSE 164TH STSE 164TH ST128TH AVE SE128TH AVE SE FOCFOCFOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOC SWSWSW SW SW SW SW SWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCSW SW SW SW SW SW SW SW SWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFLFLFLFLFLFLPOLETPOLETPOLEAPOLET127231280116332163251640716417TCP-9TCP-9TCP-10TCP-17NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-931CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--121251802453205406006607207808409Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/2022SPOTTERLIMIT SPEED R2-1 25AROADWORKAHEAD LIMITSPEEDR2-125A ROADWORKAHEADLIMITSPEEDR2-125AROADWORKAHEADNOTE:ADJACENT BUSINESSES AND/ORRESIDENT'S WILL BE NOTIFIED INWRITING 48 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.NOPARKINGFROMTOTOW-AWA Y AR EA R CW 4 6 55 11 3 NOPARKINGFROMTOTOW-AW AY A REA RCW 4 6 5 5 11 3 LIMITSPEEDR2-125A ROADWORKAHEAD24'35' Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/WR/WR/WR/WR/WR/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/W R/W R/W128TH AVE SE 128TH PL SESE 164TH STSE 164TH STSE 164TH STSE 164TH ST128TH AVE SE FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLPOLETPOLETPOLEAPOLET1280116332163251633016407TCP-9TCP-9TCP-10TCP-13TCP-17NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-1031CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084010Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/2022LIMITSPEEDR2-125A ROADWORKAHEADLIMITSPEEDR2-125A ROADWORKAHEADLIMIT SPEED R2-1 25AROADWORKAHEAD LIMITSPEEDR2-125A ROADWORKAHEADLIMITSPEEDR2-125AROADWORKAHEADSPOTTER36'24' Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W 128TH AVE SE128TH AVE SE 128TH PL SE 128TH PL SE 128TH PL SE 129TH AVE SE 129TH AVE SE FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOC SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWMPAP163091631716325163651637316393TCP-11TCP-14NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-1131CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084011Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/2022LIMITSPEEDR2-125C B A ROADWORKAHEADONELANEROADAHEADLIMITSPEEDR2-125CBA ROADWORKAHEADONELANEROADAHEADFLAGGERFLAGGER27' Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/WR/W128TH PL SE SE 162ND STSE 162ND ST FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOCFOCSW SW SWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWMP1281412808TCP-12NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-1231CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084012Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/2022LIMITSPEEDR2-125C B AROADWORKAHEADONELANEROADAHEAD LIMITSPEED R2-1 25CBA ROADWORKAHEAD ONELANEROADAHEADFLAGGERFLAGGER Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/WR/WR/W R/W R/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W 128TH PL SE 129TH AVE SESE 164TH STSE 164TH STSE 164TH STSE 164TH STSE 164TH ST128TH AVE SE128TH AVE SE FOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOC FOCFOCFOCFOCFOC SWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SWFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLMPPOLETPOLET163251633016393TCP-10TCP-13NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-1331CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084013Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/202235'25'SPOTTERNOPARKINGFROMTOTOW -A WAY ARE A RC W 46 55 1 13 NOTE:ADJACENT BUSINESSES AND/ORRESIDENT'S WILL BE NOTIFIED INWRITING 48 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.LIMIT SPEED R2-1 25AROADWORKAHEAD LIMITSPEEDR2-125A ROADWORKAHEADLIMITSPEEDR2-125AROADWORKAHEADLIMITSPEEDR2-125A ROADWORKAHEAD Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/W R/W R/W R/W R/W R/W R/W R/WR/WR/W R/WR/WR/WR/W128TH PL SE 128TH PL SE 129TH AVE SE 130TH AVE SE FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOC SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWMPAP16309163171636516373TCP-11TCP-14NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-1431CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084014Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/2022LIMITSPEEDR2-125C B A ROADWORKAHEADONELANEROADAHEADFLAGGERFLAGGERLIMITSPEEDR2-125CBA ROADWORKAHEADONELANEROADAHEAD Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W130TH AVE SE 130TH AVE SESE 164TH STSE 164TH STSE 164TH STSE 164TH STFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SWFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLMP1301216376TCP-15NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-1531CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084015Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/2022NOTE:ADJACENT BUSINESSES AND/ORRESIDENT'S WILL BE NOTIFIED INWRITING 48 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.LIMITSPEED R2-1 25AROADWORKAHEAD LIMITSPEEDR2-125A ROADWORKAHEADLIMITSPEEDR2-125AROADWORKAHEADNOPARKINGFROMTOTOW -AW AY A RE A RCW 46 5 5 1 13 35'23' Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/WR/W R/W R/W R/W R/W 131ST AVE SE131ST AVE SEFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SW MP1630916303TCP-16NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-1631CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084016Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/2022FLAGGERFLAGGERLIM I T S P E E D R 2 - 1 2 5CB AR O A DWO R K A H E A D O N E L A N E R O A D A H E A D LIMITSPEEDR2-125CBAROADWORKAHEADONELANEROADAHEAD Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/W R/W R/W R/W SE 164TH STSE 164TH STSE 164TH STSE 164TH ST128TH AVE SE128TH AVE SE128TH AVE SE FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOCFOCFOCFOC FOC FOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLMPPOLETPOLEAPOLET12801164071641716425TCP-9TCP-9TCP-17TCP-17NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-1731CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084017Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/2022SPOTTERLIMITSPEEDR2-125A ROADWORKAHEADLIMITSPEEDR2-125A ROADWORKAHEAD36'25' Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/W R/W 1 2 7 TH AVE SE SE 166TH STSE 165TH ST1 2 6 T H P L S ESE 165TH ST126TH PL SE 126TH PL SE FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOC FOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FO C FOCFOCFOCFOCFOCFOCFOC SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSW FOCFOC FOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SWSWSWSWSW SW SWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWMPAP16515165051265412660TCP-18TCP-19NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-1831CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084018Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/202227'SPOTTERFLAGGERFLAGGERLIMITSPEEDR2-125CBAROADWORKAHEADONELANEROADAHEADLIMITSPEEDR2-125C B AROADWORKAHEADONELANEROADAHEAD LIMITSPEED R2-1 25 CBAROAD WORK AHEAD ONE LANE ROAD AHEADLIMITSPEEDR2-125C B AROADWORKAHEADONELANEROADAHEADFLAGGER Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/W 1 2 7 TH A V E S E SE 165TH ST1 2 6 T H P L S ESE 165TH ST126TH PL SE 126 T H P L S E 1 2 6 T H P L S E 1 2 6 T H P L S ESE 168TH STFOC FOCFOCFO CFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FO C FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SWSW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSW FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCSWSWSW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWMAP1651516505TCP-19NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-1931CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084019Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/2022FLAGGERFLAGGERLIMITSPEEDR2-125C B AROADWORKAHEADONELANEROADAHEAD LIMITSPEEDR2-125C B A ROAD WOR K AHEA D ONELANEROA D AHEA D 28' Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/W R/W R/WR/WR/WR/WR/WR/WR/WR/W128TH AVE SE128TH AVE SE SE 167TH STSE 167TH ST FOCFOCFOCFOCFOCSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW MP1274012736TCP-20NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-2031CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084020Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/2022FLAGGERLIMITSPEEDR2-125C B AROADWORKAHEADONELANEROADAHEAD LIMITSPEEDR2-125CBA ROADWORKAHEADONELANEROADAHEADLIMITSPEEDR2-125C B A ROADWORKAHEADONELANEROADAHEAD27'FLAGGERFLAGGER Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/W R/WR/W126TH AVE SE126TH AVE SE 1 2 7 T H A V E S E SE 167TH ST126 T H P L S E FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOC F O C FO C FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFO C FO C FOC FOC FOC FOC SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWS W SW SW SW SW SW SW SWSW FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOC FO C FO C FOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FO C FO C FOC FOC FOC FOC FOC SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SWPOLET POLEMAP166171662516653TCP-21TCP-22TCP-23NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-2131CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084021Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/2022LIMITSPEEDR2-125C BAROADWORKAHEADONELANEROADAHEADLIMITSPEEDR2-125C B A ROADWORKAHEADONELANEROADAHEADFLAGGERFLAGGER28' Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W126TH AVE SE 126TH AVE SE SE 167TH ST126T H P L S E 125TH AVE SE 125TH AVE SE FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOC FO C FOC FO C FOC FOC SW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOCFOCSW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOC FO C FOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOCFOC SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SWSWSWPOLETPOLEMAP16625166331661716625TCP-21TCP-22TCP-22NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-2231CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084022Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/202235'SPOTTER24'LIMITSPEEDR2-125A ROADWORKAHEADLIMIT SPEED R2-1 25AROADWORKAHEAD LIMITSPEEDR2-125A ROADWORKAHEAD Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/W 127TH A V E S E 1 2 7 T H A V E S E 12 7 T H A V E S ESE 167TH PLSE 167TH PLFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FO C FO C FOC FOC SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFO C FO C FO C FO C FO C FO C FOC FOC FOC FOCSWSWSWSWSWSWSWSWSWSW SW S W SW SW SW SW SW SW SW SW SW SW SWAPAP127051665916653TCP-23TCP-28NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-2331CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084023Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/2022FLAGGERFLAGGERFLAGGERLIMITSPEEDR2-125C B A ROADWORKAHEADONELANEROADAHEADLIM I T SPE E D R2- 1 25CBARO A D WO R K AH E A D ON E LAN E RO A D AH E A D LIMITSPEEDR2-125C B A ROAD WORKAHEAD ONELANEROADAHEAD Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE 168TH STSE 168TH STSE 168TH STSE 168TH ST119TH AVE SE FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLPOLEM1190611902TCP-24NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-2431CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084024Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/202220'NOPARKINGFROMTOTOW- AWA Y AR EA R CW 4 6 55 11 3 NOTE:ADJACENT BUSINESSES AND/ORRESIDENT'S WILL BE NOTIFIED INWRITING 48 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.LIMITSPEEDR2-125A ROADWORKAHEADLIMITSPEEDR2-130AROADWORKAHEADLIMIT SPEED R2-1 30AROADWORKAHEADSPOTTER Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/WR/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WSE 168TH STSE 168TH STSE 168TH STSE 168TH STSE 168TH ST121ST AVE SE 121ST AVE SE 120TH AVE SE FOCFOCFOCFOCFOCFOCFOC FOC FOC FOC SWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW FOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLPOLEA1671512008TCP-25NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-2531CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084025Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/202220'NOPARKINGFROMTOTOW- AWA Y AR EA R CW 4 6 55 11 3 NOTE:ADJACENT BUSINESSES AND/ORRESIDENT'S WILL BE NOTIFIED INWRITING 48 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.LIMITSPEEDR2-125A ROADWORKAHEADLIMITSPEEDR2-130AROADWORKAHEADLIMITSPEED R2-1 30AROADWORKAHEADSPOTTER LIMITSPEEDR2-125A ROADWORKAHEAD Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE 168TH STSE 168TH STSE 168TH ST123RD AVE SE 122ND AVE SE FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP EOPEOPEOPEOPEOPSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLPOLEM1221212220TCP-26NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-2631CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084026Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/202220'NOPARKINGFROMTOTOW- AWA Y AR EA R CW 4 6 55 11 3 NOTE:ADJACENT BUSINESSES AND/ORRESIDENT'S WILL BE NOTIFIED INWRITING 48 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.LIMITSPEEDR2-125A ROADWORKAHEADLIMITSPEEDR2-130AROADWORKAHEADLIMITSPEED R2-1 30AROADWORKAHEADSPOTTER Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/W126TH AVE SE126TH AVE SE 125TH AVE SE 125TH AVE SE FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWPOLETPOLEATCP-27TCP-27NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-2731CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084027Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/202236'23'LIMITSPEEDR2-125A ROADWORKAHEADLIMITSPEEDR2-125A ROADWORKAHEADSPOTTER Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/ W 127T H A V E S E 1 2 7 T H A V E S E 1 2 7 T H A V E S ESE 167TH PLSE 167TH PLFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FO C SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFO C FO C FO C FO C FO C FO CSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW S W SW SW SW SW SWAPAP167141270516659TCP-23TCP-28NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-2831CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084028Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/2022LIMITSPEEDR2-125C B A ROADWORKAHEADONELANEROADAHEADLIM I T SP E E D R2- 1 25CBARO A D W O R K AH E A D ON E LA N E RO A D AH E A D LIMITSPEEDR2-125C B A ROAD WORKAHEADONELANEROADAHEADFLAGGERFLAGGERFLAGGER27' Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE 168TH STSE 168TH STSE 168TH ST127TH AVE SE FOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLPOLEM127041271416714TCP-29NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-2931CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084029Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/202220'NOPARKINGFROMTOTOW- AWA Y AR EA R CW 4 6 55 11 3 NOTE:ADJACENT BUSINESSES AND/ORRESIDENT'S WILL BE NOTIFIED INWRITING 48 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.LIMITSPEEDR2-125A ROADWORKAHEADLIMITSPEEDR2-130AROADWORKAHEADLIMIT SPEED R2-1 30AROADWORKAHEADSPOTTER Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/WR/WR/WR/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE 168TH STSE 168TH ST128TH AVE SE128TH AVE SE FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP EOP EOP EOP EOP EOP EOPSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFLFLFLFLFLFLFLFL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLPOLEMPOLEM127581676316760TCP-30TCP-31NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-3031CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084030Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/202220'NOPARKINGFROMTOTOW- AWA Y AR EA R CW 4 6 55 11 3 NOTE:ADJACENT BUSINESSES AND/ORRESIDENT'S WILL BE NOTIFIED INWRITING 48 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.LIMITSPEEDR2-125A ROADWORKAHEADLIMITSPEEDR2-130AROADWORKAHEADLIMIT SPEED R2-1 30AROADWORKAHEADSPOTTERLIMITSPEED R2-125A ROADWORKAHEAD Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 R/WR/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE 168TH STSE 168TH ST128TH AVE SE128TH AVE SE FOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP EOP EOP EOP EOP EOP EOPSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFLFLFLFLFLFLFLFL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLPOLEMPOLEM127581676316760TCP-30TCP-31NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-3131CONSTRUCTION TCP NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OFCURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED.SPOTTER IS NOT TOTRAFFIC CONTROL.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES WILL CONFORM TO SPECIFICATIONS STATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINES FOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED,IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILE PASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHEN SCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART:COMMENCE WORK.ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSABCDFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBAN ARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--1212518024532054060066072078084031Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMS9/12/22ADD TCPSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)AMS9/12/202238'27'LIMITSPEEDR2-125A ROADWORKAHEADLIMIT SPEED R2-1 25AROADWORKAHEADLIMITSPEEDR2-125AROADWORKAHEADLIMITSPEEDR2-125A ROADWORKAHEADNOTE:ADJACENT BUSINESSES AND/ORRESIDENT'S WILL BE NOTIFIED INWRITING 48 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.NOPARKINGFROMTOTOW-AW AY A REA RCW 4 6 5 5 11 3 SPOTTER Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 SEFNCOCOMMUNICATIONSEQUIPMENT REPLACEMENTCOMCASTT2B/D - WAKVD02U00 1x2 - WAKVD02T00 2x4 (KV19C 2x2)12801 SE 164TH ST RENTON 98058JB# 897826 CUTOVER POLEPOLE POLE POLE POLE POLE POLE POLE POLE POLE P PP P P P P P P P P P P PPOLE POLE POLE POLEPOLE POLE POLE POLE POLE POLE POLE 12630 12636 16127 16121 12647 12643 12690 12800 12817 12825 12704 12712 12814 12808 1630216308 12715 12723 12801 1630916317 16332 16325 1636516373 16330 16393 13012 16376 16309 1630316515 16505 12654 12660 1662516633 16617 16625 127401273611906119021671512008 12212 12220 12704 12714 16714 12705 16659 16653 12758 16763 16760 164071641716425 T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)VICINITY MAP16121 126TH AVE SERENTON, WACONTACTSPG#SHEET INDEX1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5-18SITE-PLAN19TYPICAL DETAILS19N/AN/ADESCRIPTION OF WORKTOTALREPLACE EQUIPMENT AT AERIAL LOCATION21REPLACE EQUIPMENT AT UG LOCATION14TOTAL:35VICINITY MAP BEGIN16760 128TH AVE SERENTON, WAEND2PERMITTINGASHLEY KIEHN4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 999-2271EMAIL: ASKIEHN.SEFNCO.COMCOMCASTSEFNCO OPEANDREW PARKERPUYALLUP, WAPHONE: (253) 225-0593EMAIL: ANDREW_PARKER2@COMCAST.COMSTEVE HARSHFIELD4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 266-4741EMAIL: STHARSHFIELD@SEFNCO.COMAMS8/22/2022S1S2S3S4S5S6S7S8S9S10S11S12S13S14 T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)19N/AN/AGENERAL NOTES 3THE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBY DISCLAIMS ANYRESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREACOVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THELOCATION OF UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEEDSITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTIONREGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARDSHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BYTHE LOCAL JURISDICTION INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BEPROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTINGUTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON ASBEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THECONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTIONPOINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TORELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLEAGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST 48 HOURS PRIORTO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLICIMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALL UTILITYCOMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURINGCONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUMDISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIESAFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THEAPPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSIONAGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO:EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HISSUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOTIDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEERIMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD,UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THE CONTRACTORSHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL.PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALLBE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAIDPLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCALJURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THECOMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BEPROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE ANDCLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORDDRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT ALLTIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONALINFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED INGOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITHHARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCAL JURISDICTIONENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNINGOF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATEDEQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TO DIGGING.AMS8/22/2022 T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)19N/AN/ALEGEND 4LEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERPOWERPARCEL LINERIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILSDSDWWSSSSGGTTLIPD/LEOPFOCRWRWBUILDING OUTLINEPFLFOG LINESIDEWALKSWSWTRENCHDIRECT BOREPROPOSED AERIAL STRAND PROOF/PULLPROPOSED OVERLASHMINOR ARTERIALCOLLECTOR ARTERIALINTERSTATE FREEWAYACCESS STREETPRINCIPAL ARTERIALBUILDINGR/WWARNING SIGN PLACEMENT (W/ PART #)TRAFFIC BARRELHYDRO-VAC TRENCHKEEPRIGHTREGULATORY SIGN (W/ PART #)LIMITSPEEDR2-125SPEED LIMIT CALLOUTSIGN PLACEMENT / DIRECTIONTRAFFIC CONEFLAGGER STATIONFLAGGER STATIONPATROL CARPOLICEOFFICERUNIFORMED POLICE OFFICERWORK VEHICLEFENCESTREET LIGHT HANDHOLETELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALSTREET LIGHT POLETRAFFIC SIGNAL HANDHOLECATV MANHOLECATV HANDHOLECATV PEDESTALTRAFFIC SIGNAL POLESTORM MANHOLEWATER VALVEWATER METERWATER MANHOLETELECOM PEDESTALSTORM INLETSTORM DISCHARGE POINTSTORM DRAIN UNKNOWN WATER UNKNOWNWATER VAULTWATER RESERVOIRD?SISEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?STORM DRAIN VAULT SDSEWER CLEANOUTSEWER MANHOLESCSEWER CATCH BASIN SSSTORM ACCESS POINTBASE LAYERSEXISTING UTILITIESROAD HATCH CLASSIFICATIONROW WORK LINETYPECOMCAST UNDERGROUND SYMBOLSEXISTING UTILITY SYMBOLSTRAFFIC CONTROL SYMBOLSSTORM CATCH BASIN SDTRAFFIC SIGNAL VAULTGAS METERTEST VALVEPEDESTAL UNK UTILITYFIRE HYDRANTGAS VALVEGAS TEST POINTGAS MANHOLEWATER PUMPGGGWATER AIR CONTROL VALVEWATER WELLWATER SAMPLING STATIONPOWER HANDHOLEPOWER MANHOLEPOWER CABINETPOWER VAULTPOWER PEDESTALPPOWER UNKNOWN PPPPPP?SIGN POSTCULVERTTRANSIT STOPBUSSTOPDRIVEWAY (FOC OR EOP)SDSSANCHORSIDEWALK ANCHOR & GUY(P) FIBER & COUNTF48(P) .625 COAX(P) .875 COAXCOMCAST AERIAL SYMBOLSPROPOSEDEXISTINGWRECKOUTPOLE W/O RISERRISERARMVERTICAL GROUNDSLACK SPANOVERHEAD GUYTANGENT ATTACHMENTDEAD-ENDDOUBLE DEAD-END(E) FIBER & COUNTF48(E) .625 COAX(E) .875 COAXSLSLTSTSTSTSCCCTTTTWWTSTS?PUMPFWELLWTREE TRIMLIGHT/MEDIUM/HEAVYLMH//WRECKOUTVAULTSPLICE CASEMANHOLENode SymbolPEDESTALNode SymbolNode SymbolPAMINIBRIDGERTTTAATAPAMPLIFER POTHOLEBORE PIT / EXCAVATIONMMMPROPOSEDEXISTINGWRECKOUTNODENode SymbolABCDNode SymbolSTORAGE LOOPX'X'W?LIT INTERSECTIONFASFLASHING ARROWSEQUENTIAL ARROWSEQUENTIAL CHEVRONFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONORFLASHING DIAMOND CAUTIONARROWBOARD PLACEMENT (SEE BELOW)CHANNELIZING DEVICES / MIN DIMENSIONSNOTE(S):1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE, LEGIBILITYDISTANCE, NUMBER OF ELEMENTS AND OTHERSPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OF ARROWHEADEQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVE SOLIDRECTANGULAR APPEARANCES. A TYPE D ARROW BOARDSHALL CONFORM TO THE SHAPE OF THE ARROW.ARROWBOARD TYPE MIN LEGIBILITYDISTANCEMIN SIZE MINIMUM# OFELEMENTSABCD48"×24"60"×30"96"×48"NONE12 MILE1 MILE34 MILE12 MILE121315125FT MIN4FT MIN8-12"45°TYPE 3 BARRICADE3FT MIN45°2FT MIN8-12"TYPE 1 BARRICADE3FT MIN8-12"2FT MIN45°TYPE 2 BARRICADE3-4"6"2"4"28'-36" MAXSPEED < 45MPHNIGHT AND/OR FREEWAYMORE THAN 36"4-6" TYPCONECONESPEED ≥ 45MPHDIRECTION INDICATOR BARRICADE12"8"36" MIN 24" MIN45°UNLIT INTERSECTIONDBTRENCHAVAC-TSPOTTER STATIONALL TRAFFIC CONTROL DEVICES / ANNOTATIONS PER MUTCDAMS8/22/2022 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/WR/WR/WR/W R/WR/WSE 161ST STSE 161ST STSE 161ST ST126TH PL SE 126TH PL SE126TH AVE SE126TH AVE SE126TH AVE SEFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOCFOCFOCFOC FOCFOCFOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSW SW SWSWSWSW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SWSWSWSWSW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSW SW SWSWSWSWSW SW SW SW SW SW SWSWSWSWSWSWSW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW POLEMPOLEMPOLEA126301263616127161211264712643MATCH LINE SITE PLAN-2MATCH LINE SITE PLAN-4T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)N19SITE PLAN - 1 5Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.SITE PLAN CONSTRUCTION NOTES12REPLACE EQUIPMENT AT AERIALLOCATIONREPLACE EQUIPMENT AT UGLOCATIONAMS8/22/2022111 R/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE 161ST STSE 161ST STSE 161ST STSE 162ND STSE 162ND ST128TH AVE SE 128TH AVE SE 128TH AVE SE FOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFO C FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWMPPOLEM12690128001281712825MATCH LINE SITE PLAN-1 MATCH LINE SITE PLAN-3MATCH LINE SITE PLAN-5T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)N19SITE PLAN - 2 6Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.SITE PLAN CONSTRUCTION NOTES12REPLACE EQUIPMENT AT AERIALLOCATIONREPLACE EQUIPMENT AT UGLOCATIONAMS8/22/202212 R/WR/WR/W R/W R/W R/WR/W128TH PL SE SE 162ND STSE 162ND ST131ST AVE SEFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSW SW SW SW SW SW SW SW SW SW SW SW SW SWSW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWMP1281412808MATCH LINE SITE PLAN-2 MATCH LINE SITE PLAN-6T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)N19SITE PLAN - 3 7Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.SITE PLAN CONSTRUCTION NOTES12REPLACE EQUIPMENT AT AERIALLOCATIONREPLACE EQUIPMENT AT UGLOCATIONAMS8/22/20222 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/WR/WR/W R/W R/W SE 163RD ST126TH AVE SE126TH AVE SE 127TH AVE SE 127TH AVE SESE 164TH STSE 164TH STSE 164TH STFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOC FOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSW SW SWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWPOLEPOLEM127041630216308MMATCH LINE SITE PLAN-5 MATCH LINE SITE PLAN-1T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)N19SITE PLAN - 4 8Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.SITE PLAN CONSTRUCTION NOTES12REPLACE EQUIPMENT AT AERIALLOCATIONREPLACE EQUIPMENT AT UGLOCATIONAMS8/22/202211 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE 163RD STSE 163RD ST128TH AVE SE 128TH AVE SE128TH AVE SE 128TH AVE SE 127TH PL SE 128TH PL SE 128TH PL SE 128TH PL SESE 164TH STSE 164TH STSE 164TH STSE 164TH STSE 164TH STFOCFOCFOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC SWSWSW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSW FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOC FOC SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFLFLFLFLFLFLFLFLFLFLFLAPPOLETPOLEAPOLETPOLEM1271212715127231280116309163171633216325MATCH LINE SITE PLAN-4 MATCH LINE SITE PLAN-6 MATCH LINE SITE PLAN-2MATCH LINE SITE PLAN-7T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)N19SITE PLAN - 5 9Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.SITE PLAN CONSTRUCTION NOTES12REPLACE EQUIPMENT AT AERIALLOCATIONREPLACE EQUIPMENT AT UGLOCATIONAMS8/22/202221111 R/WR/WR/W R/W R/W R/WR/WR/WR/WR/W R/W R/W R/WR/WR/WR/WR/WR/WR/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W131ST AVE SE129TH AVE SE 129TH AVE SE 130TH AVE SE 130TH AVE SE 131ST AVE SESE 164TH STSE 164TH STSE 164TH STSE 164TH STSE 164TH STSE 164TH STFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOCFOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOC FOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLMPMPMPMP1636516373163301639313012163761630916303MATCH LINE SITE PLAN-5 MATCH LINE SITE PLAN-3T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)N19SITE PLAN - 6 10Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.SITE PLAN CONSTRUCTION NOTES12REPLACE EQUIPMENT AT AERIALLOCATIONREPLACE EQUIPMENT AT UGLOCATIONAMS8/22/20222222 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/W 128TH AVE SE128TH AVE SE128TH AVE SE 128TH AVE SESE 166TH STSE 165TH ST126TH PL S E SE 165TH STSE 165TH ST126TH PL SE 126TH PL SE FOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOCSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SWFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFO C FOCFOCFO C FOC FOC FOCFOCFOCFOCFOC FOCFOCFOCFOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOC FOC FOC FOCFOC FOC FOC FOC FOC SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SWSW FOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SWMPAPMPPOLET16515165051265412660164071641716425MATCH LINE SITE PLAN-5MATCH LINE SITE PLAN-9T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)N19SITE PLAN - 7 11Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.SITE PLAN CONSTRUCTION NOTES12REPLACE EQUIPMENT AT AERIALLOCATIONREPLACE EQUIPMENT AT UGLOCATIONAMS8/22/20222212 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/W R/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/W126TH AVE SE126TH AVE SE126TH AVE SE 12 7 T H A V E S E SE 167TH ST126T H P L S E 126 T H P L S E 12 6 T H P L S ESE 168TH STSE 166TH STFOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FO C FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFO C FOC FOC FOC FOC FOC SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSW SWSW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SWSW FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFO C FOC FOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWFO C FO C FOC FOC FOC FOC SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SWPOLET POLEMAPAP166251663316617166251665916653MATCH LINE SITE PLAN-8 MATCH LINE SITE PLAN-9MATCH LINE SITE PLAN-13T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)N19SITE PLAN - 8 12Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.SITE PLAN CONSTRUCTION NOTES12REPLACE EQUIPMENT AT AERIALLOCATIONREPLACE EQUIPMENT AT UGLOCATIONAMS8/22/20222211 R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W128TH AVE SE128TH AVE SE128TH AVE SE128TH AVE SE 127TH AVE SE 127TH AVE SE SE 167TH STSE 1 6 7 T H S T FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW MP1274012736MATCH LINE SITE PLAN-8 MATCH LINE SITE PLAN-7MATCH LINE SITE PLAN-14T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)N19SITE PLAN - 9 13Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.SITE PLAN CONSTRUCTION NOTES12REPLACE EQUIPMENT AT AERIALLOCATIONREPLACE EQUIPMENT AT UGLOCATIONAMS8/22/20222 R/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE 168TH STSE 168TH STSE 168TH STSE 168TH ST119TH AVE SESE 170TH PLSE 167TH STSE 167TH STSE 167TH STSE 167TH ST SE 1 6 7 T H S T 119TH A V E S E FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOC FOC FOCFOCFO C FOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FO C FO C FOCFOCEOPEOPEOPEOPEOPEOPEOP EOPEOPEOPEOPSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLPOLEM1190611902MATCH LINE SITE PLAN-11 T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)N19SITE PLAN - 10 14Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.SITE PLAN CONSTRUCTION NOTES12REPLACE EQUIPMENT AT AERIALLOCATIONREPLACE EQUIPMENT AT UGLOCATIONAMS8/22/20221 R/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE 168TH STSE 168TH STSE 168TH STSE 168TH STSE 168TH ST122ND AVE SE 121ST AVE SE 121ST AVE SE 120TH AVE SE 121ST AVE SESE 167TH STSE 167TH STSE 167TH STFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOC FOC FOC SWSWSWSW SW SW SW FOC FOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC SW SW SWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW FOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOC FOC FOC FOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SWSW SW SWSW SWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCEOPEOPEOPEOPEOPEOPEOPEOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLPOLEA1671512008MATCH LINE SITE PLAN-10 MATCH LINE SITE PLAN-12 T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)N19SITE PLAN - 11 15Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.SITE PLAN CONSTRUCTION NOTES12REPLACE EQUIPMENT AT AERIALLOCATIONREPLACE EQUIPMENT AT UGLOCATIONAMS8/22/20221 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/WR/WR/WR/WSE 168TH STSE 168TH STSE 168TH ST125TH AVE SE 125TH AVE SE 125TH AVE SE 124TH AVE SE 123RD AVE SE SE 167TH STSE 1 6 7TH S T SE 167TH ST124 T H A V E S E FOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC SWSWSW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOCFOC FOCFOCFOCFOCFOC FOC FOC FOC FOCFOC FOCFOC SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSW SW SWSWSWSW SWSWSWSWSWSW SW SW SW SW SW SW SWSWSW SWSW SWFOCFOCFOCFOCFOCFOC FO C FO C FOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSW SW SW SW SWSW SWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCEOPEOPEOPEOPEOPEOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPSWSWSWSWSWSWSWSWSWSWSWSWSW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLPOLEMFLFLFLFLFLFLFLFLFLFL1221212220MATCH LINE SITE PLAN-11 MATCH LINE SITE PLAN-13 T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)N19SITE PLAN - 12 16Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.SITE PLAN CONSTRUCTION NOTES12REPLACE EQUIPMENT AT AERIALLOCATIONREPLACE EQUIPMENT AT UGLOCATIONAMS8/22/20221 R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W126TH AVE SE126TH AVE SESE 168TH STSE 168TH STSE 168TH STSE 168TH ST126TH AVE SE 127TH AVE SE 127T H A V E S E 12 7 T H A V E S E SE 167TH PLFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFO C FOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSW SWSWSWSWSWSWSWSW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOC SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSW FOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFO C FO C FO C FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCEOPEOPEOPEOPSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLPOLEMPOLETPOLEAAP12704127141671412705MATCH LINE SITE PLAN-12 MATCH LINE SITE PLAN-14 MATCH LINE SITE PLAN-8T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)N19SITE PLAN - 13 17Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.SITE PLAN CONSTRUCTION NOTES12REPLACE EQUIPMENT AT AERIALLOCATIONREPLACE EQUIPMENT AT UGLOCATIONAMS8/22/20221112 R/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE 168TH STSE 168TH STSE 168TH ST128TH AVE SE128TH AVE SE128TH AVE SE128TH AVE SE SE 167TH PLFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOC FOCFOCFOCFOC FOCFOCFOCFOCFO C FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCEOPEOPEOPEOPEOPEOPEOPEOPEOP EOP EOP EOP EOP EOP EOP EOP EOP EOP FOC FOCFOC FOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFLFLFLFL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLPOLEMPOLEM127581676316760MATCH LINE SITE PLAN-13 MATCH LINE SITE PLAN-9T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)N19SITE PLAN - 14 18Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.SITE PLAN CONSTRUCTION NOTES12REPLACE EQUIPMENT AT AERIALLOCATIONREPLACE EQUIPMENT AT UGLOCATIONAMS8/22/202211 19REVISIONSDATEDESCRIPTIONINITIALTYPICAL DETAILS T2B/D - WAKVD02U00 1x2 - 12801 SE 164TH ST RENTON, WA 98058 JB#897826REVISIONSDATEDESCRIPTIONINITIAL8/22/22ADD DETAILSAMSCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSWAKVD02T00 2x4 (KV19C 2x2)NTS19TYPICAL DETAILS Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.AMS8/22/2022STARLINE SERIES: BLE100AUX1 GHz AMPLIFIERFEATURES:·SIMPLIFY PLANT UPGRADES WITH MODULAR RF DESIGNAND 1.2 GHZ CAPABLE HOUSING·IMPROVE AMPLIFIER REACH WITH OPTIONAL GANTECHNOLOGY AND INCREASED STATION TILT·MAINTAIN CURRENT AMPLIFIER SPACING WITH HIGHOUTPUT GAAS TECHNOLOGY·EXPAND RETURN PATH BANDWIDTH WITH PLUG‐INDIPLEX FILTER SUPPORT TO 85 MHZ·MINIMIZE RF DRIFT OVER TEMPERATURE WITH OPTIONALANALOG OR QAM ADUHOUSING DIMENSIONS (L×W×D): 15.4" x 9.6" x 5.5"292 mm x 244 mm x140 mmWEIGHT:15 lb6.8kgFFT*-* Q SERIES·FFT2-*Q: 2 PORT TAPS·FFT4-*Q: 4 PORT TAPS·FFT8-*Q: 8 PORT TAPS·FFT*-PBA-V: 2 PORT TAPSFEATURES:·SUPPORT DOCSIS 3.1 EXPANDED BANDWIDTH UP TO1218 MHz.·IMPROVE NETWORK PERFORMANCE WITH SIGNALCONDITIONING PLUG-INS.·HIGH QUALITY RF CONNECTION WITH AUTO-SEIZEF-CONNECTORS.·MAINTAIN EXISTING INSTALLED BASE WITHCOMPATIBILITY BACK TO "F" SERIES FFT HOUSINGS.·STANDARD FACEPLATE ONLY OPTIONS FORCOST-EFFECTIVE UPGRADES TO EXISTING FFTDEPLOYMENTS.·HIGH LEVEL OF NETWORK RESILIENCE WITH 6 kVSURGE RESISTANCE ON FEEDERLINE AND F-PORTS.·BLANK TAP OPTION FFT*-PBA-V FOR FUTUREEXPANSION·MAINTAIN RF AND AC CONNECTIONS WITH FACEPLATEREMOVED WITH INTEGRATED BYPASS CAPABILITY.HOUSING DIMENSIONS (L×W×D): 4.0" x 2.9" x 5.6"10.2cm x 7.4cm x 14.2cmWEIGHT:1 lb0.45kgHARDWARE REPLACEMENT DIMENSIONSAMPLIFIERTAPSTARLINE SERIES: MB1001 GHz MINIBRIDGERFEATURES:·SIMPLIFY PLANT UPGRADES WITH MODULAR RFDESIGN AND 1.2 GHZ CAPABLE HOUSING·IMPROVE AMPLIFIER REACH WITH OPTIONAL GANTECHNOLOGY AND INCREASED STATION TILT·MAINTAIN CURRENT AMPLIFIER SPACING WITH HIGHOUTPUT GAAS TECHNOLOGY·EXPAND RETURN PATH BANDWIDTH WITH PLUG‐INDIPLEX FILTER SUPPORT TO 85 MHZ·MINIMIZE RF DRIFT OVER TEMPERATURE WITHOPTIONAL ANALOG OR QAM ADUHOUSING DIMENSIONS (L×W×D): 15.4" x 9.6" x 5.5"292 mm x 244mm x 140 mmWEIGHT:15 lb6.8kgMINIBRIDGER