LEGAL DESCRIPTION
PUGET
SOUND
ENERGY
PARCEL #202305-9003:
SWI,4 OF NEI,4 LESS PORLY BET PSPBL CO 50 FT ESMT B BPA 200 FT ESMT LESS FOR
D POR WITHIN PSPBL CO 200 FT SHUFFLETON R/W SUBJ TO ESMTS TCO 17-802
PARCEL #202305-9066:
POR OF SE'/4 OF NE'/4 LY WLY OF C OF S PIPE LN R/W ALSO POR SD SUBD LY NLY
OF SLY LN OF BONNEILLE TRANS LN ESMT R/W B ELY OF C OF S PIPE LN R/W SUBJ
TO ESMTS - TCO 17-741
SITE DATA:
LOCATION: 2400 S PUGET DRIVE, RENTON WA 98055
SURVEY NOTES
TAT BOT HILL
SUBSTATION
0�
230KV CLR STATION
1. SURVEY REFERENCE
REFERENCED SURVEY WAS PERFORMED IN AUGUST AND SEPTEMBER, 2014 AND OCTOBER, 2015 IN SUPPORT
OF A PUGET SOUND ENERGY SUBSTATION UPGRADE PROJECT. SURVEY DATA PROVIDED BY
PUGET SOUND ENERGY FOR USE IN THIS WORK
2. BASIS OF BEARING
WASHINGTON COORODINATE SYSTEM, NORTH ZONE, NAD83 (NSRS 2011).
3. VERTICAL DATUM
NAVD 88
NOTE: NGVD 29 = NAVD 88 MINUS 3.5'. SOURCE - CORPSCON FOR WINDOWS CONVERSION
SOFTWARE VERSION 6.0.1.
C 4. SITE BENCHMARKS
w
O
SE �/4 SECTION 30, TOWNSHIP 23 NORTH., RANGE 5 EAST., W.M.
DEA CONTROL POINT NO. 3006, A 1/2" REBAR WITH "DEA CONTROL" CAP AT THE TURN
INTO THE SUBSTATION, 75' S360W FROM POWER POLE 317326/166450. ELEV = 436.88 FEET.
DEA CONTROL POINT NO. 3008, A MAG NAIL AND "DEA CONTROL" WASHER IN THE TALBOT
STATION, 87' S880E FROM A CATCH BASIN AND 39' N770E FROM A CATCH BASIN. ELEV = 438.63 FEET.
AREA PLAN
200 0 200 400
GRAPHIC SCALE
1 " = 200'
S • PUGt
SURVEY NOTES (CONTINUED)
6. PROPERTY LINES
THIS IS NOT A BOUNDARY SURVEY. PROPERTY LINES SHOWN HEREON ARE BASED UPON READILY
AVAILABLE PUBLIC RECORDS TOGETHER WITH LOCAL MONUMENT TIES AND ARE SHOWN FOR GRAPHIC
PURPOSES ONLY. PROPERTY CORNERS WERE NOT STAKED IN CONJUNCTION WITH THIS SURVEY.
7. MONUMENT VISITAION
ALL SURVEY MONUMENTS AND OTHER SURVEY MARKERS SHOWN HEREON WERE VISITED DURING
DECEMBER, 2008 UNLESS OTHERWISE INDICATED.
8. ENCUMBRANCES
CHICAGO TITLE INSURANCE COMPANY PLAT CERTIFICATE DATED 2008 USED FOR LAND DESCRIPTION
AND ENCUMBRANCES OF RECORD. NO FURTHER SEARCH INTO THE RECORD WAS REQUESTED OR PERFORMED.
9. UNDERGROUND UTILITIES
UNDERGROUND UTILITIES SHOWN REPRESENT FIELD SURVEYED PAINT MARKS AS PLACED ON THE GROUND BY A
PRIVATE UTLITIY LOCATE SERVICE TOGETHER WITH AVAILABLE UTILITY AS -BUILT AND REFERENCE DRAWINGS.
NO GUARANTEE IS MADE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA,
EITHER IN SERVICE OR ABANDONED OR THAT THE UNDERGROUND UTILITIES ARE SHOWN IN THEIR EXACT LOCATION.
THE UTILITIES ARE SHOWN AS ACCURATELY AS POSSIBLE FROM AVAILABLE INFORMATION.
10.CONTOUR INTERVAL
1 FOOT
11.SUBSURFACE CONDITIONS
SUBSURFACE CONDITIONS WERE NOT EXAMINED OR CONSIDERED AS PART OF THIS SURVEY.
12.1-800-424-5555
GENERAL NOTES
1. ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS
OF THE LATEST STATE OF WASHINGTON DEPARTMENT OF TRANSPORTATION STANDARD
SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION AND THE CITY/COUNTY PUBLIC
ROAD STANDARDS UNLESS OTHERWISE NOTED.
2. IT WILL BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT ALL UTILITY COMPANIES TO
COORDINATE CONSTRUCTION. ALL UTILITY RELOCATION WORK SHALL BE AT THE EXPENSE OF
THE APPLICANT AND MUST BE IN ACCORDANCE WITH THE STANDARDS OF THE CITY/COUNTY.
3. BURIED UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION. THE CONTRACTOR
SHALL HAVE THE UTILITIES VERIFIED ON THE GROUND PRIOR TO ANY CONSTRUCTION.
4. ANY REVISIONS TO THESE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY/COUNTY
DEVELOPMENT ENGINEERING SECTION PRIOR TO ANY IMPLEMENTATION IN THE FIELD.
5. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION
IS IN PROGRESS.
6. BEFORE WORKING IN THE CITY/COUNTY RIGHT-OF-WAY, THE CONTRACTOR SHALL:
A. OBTAIN A GENERAL PERMIT FROM THE CITY/COUNTY.
B. SUBMIT A FINANCIAL GUARANTEE TO THE CITY/COUNTY TO ASSURE SATISFACTORY
COMPLETION OF THE WORK.
C. PROVIDE PROOF OF LIABILITY INSURANCE IN AN AMOUNT REQUIRED BY THE CITY/COUNTY.
7. THE CONTRACTOR SHALL NOTIFY THE APPLICANT'S ENGINEER IN THE EVENT OR DISCOVERY
OF POOR SOILS, STANDING GROUNDWATER, OR SEVERE DISCREPANCIES FROM SOIL LOG
DESCRIPTIONS AS NOTED ON THESE PLANS.
8. ISSUANCE OF A SITE DEVELOPMENT PERMIT BY THE CITY/COUNTY DOES NOT IMPLY OR SIGNIFY
THAT THE PROPOSED WORK COMPLIES WITH THE REQUIREMENTS OF OR IS ALLOWED BY OTHER
ORDINANCES, REGULATIONS, OR REQUIREMENTS, OR STATE OR FEDERAL LAWS. CONTRACTOR WILL
ACCEPT SOLE RESPONSIBILITY AND LIABILITY FOR COMPLIANCE WITH ALL STATE, FEDERAL, AND
LOCAL RULES, REQUIREMENTS, LAWS, ORDINANCES, AND REGULATIONS.
9. THE CITY/COUNTY IS AUTHORIZED TO MAKE INSPECTIONS AND TAKE SUCH ACTIONS AS REQUIRED
TO ENFORCE THESE REGULATIONS. THE CITY/COUNTY REPRESENTATIVE SHALL PRESENT PROPER
CREDENTIALS AND MAKE A REASONABLE EFFORT TO CONTACT THE PROPERTY OWNER BEFORE
ENTERING ONTO PRIVATE PROPERTY.
10. SHOULD THE CITY/COUNTY BECOME AWARE OF CONDITIONS THAT INVALIDATE THE ORIGINAL DESIGN
DATA USED TO OBTAIN THE PERMIT OR DETERMINE THAT THE APPLICANT IS NOT COMPLYING WITH
THE CONDITIONS OF THE PERMIT OR APPROVED PLANS, THE CITY/COUNTY MAY REVOKE THE ORIGINAL
PERMIT AND/OR ORDER WORK STOPPED ON THE PROJECT. THEY MAY REQUIRE THE APPLICANT TO
RESUBMIT INFORMATION OR PLANS FOR REVIEW AND APPROVAL AND APPLY FOR A NEW PERMIT.
11. SEE DRAWING D-19980 SHT 2 FOR ADDITIONAL CITY OF RENTON STANDARD PLAN NOTES.
DRAWING LIST®
P 1- 1.I( - ( I I T kI!l- TT TI r
D-19980 2
CITY OF RENTON STANDARD PLAN NOTES
D-19982 1
TEMPORARY EROSION/SEDIMENT
CONTROL PLAN
D-19983 1
TEMPORARY EROSION/SEDIMENT
CONTROL NOTES AND DETAILS
D-19984 1
GRADING AND FENCING PLAN,
SECTIONS AND DETAILS
D-19985 1
ACCESS ROAD PLAN, PROFILES
AND SECTIONS
D-19986 1
CHAIN LINK FENCING SECTION
AND DETAILS
D-19988 1
FOUNDATION PLAN
D-19989 1
VERTICAL BUS STRUCTURE
R-41 1 701
REVISION DESCRIPTION:
AS -BUILT
SEEN LON�F 7/20/21
�� WAS�y�r�C p�
��L �� �"
[�,2�5492
SIONAL�'�
PSE ENGINEERING CONTACTS
355 110TH AVE NE, BELLEVUE WA. 98004
GROUP
NAME
PHONE
EMAIL
PROJECT
MANAGEMENT
JEFF McMEEKIN
425-462-3824
Jeff.mcmeekin@pse.com
ELECTRICAL
ALISON KLIMA
206-914-8621
alison.klima@pse.com
CIVIL
CHRIS RUSSELL
425-766-3529
christopher.russell@pse.com
CONSTRUCTION
MANAGEMENT
CODY SPENCE
425-466-8946
cody.spence@pse.com
CONTROLS
YUNG FU
425-922-1742
yung.fu@pse.com
PERMITTING
BRAD STRAUCH
425-456-2556
bradley.strcuch@pse.com
WO NUMBER:111024154
WO NUMBER:111024153
Know what's below.
Call before you dig.
SITE PLAN AND GENERAL NOTES
CLR TALBOT HILL SUBSTATION
800
DATE (M/D/Y) PUGET
CAD SDS 01 / 11 / 21 SOUND
ENGINEER HSL 01 / 11 / 21 ENERGY
REVIEWED HSL 01 / 11 / 21 SCALE: NONE
APPROVED / / CADD NO: $$DGN$$
SUBSTATION
ENGINEERING
DEPARTMENT
CLASS: S I TE
DRAWING NO REV NO
D-1 9980 3
SHEET: 1 OF 2
FILE NO:
CODE: TAL
0
rn
Q
O
0
0
O
N
U
E
u
14
0
8 1 7 1 6 1 5 ' 4 1 3 ' 2 ' 1
C:*Users*bmohideen*OneDrive - POWER Engineers, Inc*Desktop*Work-From-Home*Talbot Hill MU for Basheer*D-19980-01.dgn