Loading...
HomeMy WebLinkAboutMFP22002001.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP22002001 IVR Number: 22002001 Permit Information Permit Name: JB0000966663 - 801 S 3RD ST RENTON Address/Location:04/15/2022Application Date:7231501755Parcel Number: 801 S 3RD ST Permit Type:09/21/2022Issue Date:Franchise Permit Work Class:09/21/2023Expiration Date:Minor Utility Job Number: JB0000966663Franchise Type:Cable Description: Comcast proposes to bore (2) 2" conduit W .625 coax 284LF. POTHOLE ALL EXISTING UTILITIES. RESTORATION PER CITY OF RENTON STANDARDS. Contacts Name Address PhoneTypeBilling Rhonda Resnik Comcast 410 Valley Ave NW, Suite 12, Bldg C Puyallup, WA 98371 B: (253) 864-4246Applicant Ashley Kiehn 4610 Tacoma Avenue Sumner, WA 98390 ApplicantX Tom Donnelly Comcast Business Communications 1701 Jfk Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact Andrew Parker comcast 410 Valley Ave NW Puyallup, WA 98371 B: (253) 864-4249Contact Andrew Parker Comcast 410 Valley Ave NW, Suite 12 Bldg C Puyallup, WA 98371 B: (253) 225-0596Contact Sandra Castro Comcast C: (209) 561-4786Contact Scott Nall SEFNCO Communications Inc 2904 4th Ave NE Puyallup, WA 98372 B: (877) 385-2903 C: (253) 444-9057 Contractor Business License Number: 41108Construction Contractor: SEFNCCI850QD CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐ Electronic Copy of the TCP Application ☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:  Include map(s) showing the location of the project and work area.  Be legible lettering and clear, contrasting, symbols of viewing or printing.  Must indicate street names, and north arrow and scale.  Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering JB0000966663 - 801 S 3RD ST RENTON 801 S 3RD ST RENTON, WA 98057 MFP22002001 07-18-2022 07-22-2022 9:00AM 3:30PM SEFNCO COMMUNICATION Ashley Kiehn 4610 TACOMA AVE SUMNER WA 98090 Comcast proposes to bore (2) 2" conduit W/ .625 coax 284LF; 253-222-9971 Monday - Friday Scott Warlick CED 9/21/2022 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING:  Must have approved Traffic Control Plan (TCP) prior to commencing the work.  Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians.  WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way.  Comply with all traffic regulations of the City of Renton and the State of Washington.  Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices.  Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.  Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work.  Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions.  Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.  Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees.  The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim.  In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same.  Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel.  All permit conditions shall be met. NOTES:  Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.  Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT.  Approved Temporary Traffic Control Plan must be at the work site during work hours.  Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone.  Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours.  Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021  In the case of Temporary No Parking Zones, all the following apply in addition to previous:  Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage.  Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time.  The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site.  Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) 06-10-2022 Kakai Bojang - Permit Coordinator FOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCFOC FOC FOCFOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOCFOCFOCFOCFOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOCFO C FOCFOCFOCSWSWSWSWSWSWSW SW SWSWSWSW SWSWSWSW SW SWSWSWSWSWSW SWSW SW SW SWSWSWSW SWSWSWSWSW SW SW SWSWSWSWSWSWSWSWSWSWSW SW SW SWSWSWSWSW SWSW SWSW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSW WELLS AVE S WELLS AVE SS 3RD ST (SR 900)S 3RD ST (SR 900)S 3RD ST (SR 900)WILLIAMS AVE S WILLIAMS AVE S WELLS AVE S WILLIAMS AVE S HOUSER WY SONE WAYDBDBDBBURNETTE AVE S BURNETTE AVE S BURNETTE AVE SBURNETTE AVE S WILLIAMS AVE S WELLS AVE S FOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOC?DB DBDBDBS 3RD ST (SR 900)S 3RD ST (SR 900)801 S 3RD ST RENTON 801 S 3RD ST RENTON, WA 98057 RENTON, WA 98057 JB0000966663REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSRPKREV 107/05/22ENTITY REV REQRPKREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-17/5/22ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURESWILL CONFORM TO SPECIFICATIONS STATED IN THEFEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROLDEVICES (M.U.T.C.D)CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSOADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROLWITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OFTHE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF ANDANY SPECIAL CONDITIONS EXISTSITE-SPECIFIC TRAFFIC CONTROL PLANSITE NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDE WALK TO REMAIN OPEN. (PEDESRIAN PATH PROVIDED WHERE REQUIRED) AND WILLBE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED.WILLIAMS AVE S & S 3RD ST [PROPOSED WORK: UNDERGROUND]CONTROL TYPE: (SHOULDER CLOSURE / PEDESTRIAN WITH SPOTTERS)N13TRAFFIC CONTROL PLAN NOTES1.NO LANE ENCROACHMENT SHALL OCCUR.2.WORK VEHICLE OCCUPIES SHOULDERPARKING.3.ADJACENT BUSINESSES AND/OR RESIDENT'SWILL BE NOTIFIED IN WRITING 48 HRS INADVANCE OF PLACEMENT OF "NO PARKING"SIGNS.RYAN KETTELLSID: P101KMTCS#: 012654EXPIRES: 11/30/24COMMUNICATIONSONE WAYLIMITSPEEDR2-125CROSSWALK CLOSEDCROSS HERECROSSWALK CLOSEDCROSS HEREDETOURDETOUR SIDEWALK CLOSED CROSS HERESIDEWALK CLOSEDCROSS HEREDETOURWORK AREAPOLICEPOLICE 10' MIN 20'RIGHTSHOULDERCLOSEDSHOULDERWORKROADWORKAHEADXX X20'10' MINRIGHTSHOULDERCLOSEDSHOULDERWORKROADWORKAHEADXXXNOPARKINGFROMTOTOW-AWAY AREA RCW 46 55 113RIGHTSHOULDERCLOSEDSHOULDERWORKROADWORKAHEADXXXNOPARKINGFROMTOTOW-AWAY AREA RCW 46 55 113MFP22002001 FOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOC FOC FO C FOC FOC FOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOCFOCFOCFOCFOC FOC FOCFOC FOCFOCFOCFOCFOCFOCSWSWSWSWSWSW SW SWSWSWSWSW SWSWSWSWSWSWSWSWSW SWSW SW SW SW SWSWSWSWSW SWSWSWSWSW SW SW SWSWSWSWSWSW SW SW SWSWSW SW SWSW SWSW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW WELLS AVE S WELLS AVE SS 3RD ST (SR 900)S 3RD ST (SR 900)S 3RD ST (SR 900)WILLIAMS AVE S WILLIAMS AVE S WELLS AVE S WILLIAMS AVE S HOUSER WY SONE WAYDBDBDBBURNETTE AVE S BURNETTE AVE S BURNETTE AVE SBURNETTE AVE S WILLIAMS AVE S WELLS AVE S LOGAN AVE SLOGAN AVE S FOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC?DB DBDBDBS 3RD ST (SR 900)S 3RD ST (SR 900)801 S 3RD ST RENTON 801 S 3RD ST RENTON, WA 98057 RENTON, WA 98057 JB0000966663REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSRPKREV 107/05/22ENTITY REV REQRPKREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-27/5/22ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURESWILL CONFORM TO SPECIFICATIONS STATED IN THEFEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROLDEVICES (M.U.T.C.D)CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSOADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROLWITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OFTHE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF ANDANY SPECIAL CONDITIONS EXISTSITE-SPECIFIC TRAFFIC CONTROL PLANSITE NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDE WALK TO REMAIN OPEN. (PEDESRIAN PATH PROVIDED WHERE REQUIRED) AND WILLBE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED.N2RIGHTLANECLOSEDAHEADROADWORKAHEADXXXRIGHTLANECLOSEDAHEADROADWORKAHEADXXXROADWORKAHEADROADWORKAHEADROADWORKAHEADROADWORKAHEADLIMITSPEEDR2-125LIMITSPEEDR2-125FASCROSSWALK CLOSEDCROSS HERE3ONE WAYNOPARKINGFROMTOTOW-AWAY AREA RCW 46 55 113NOPARKINGFROMTOTOW-AWAY AREA RCW 46 55 113POLICEPOLICE WORKAREACROSSWALK CLOSEDCROSS HEREDETOURDETOUR DETOURSIDEWALK CLOSEDCROSS HERENOTE: SIGN SHALL BE PLACED ATNE CORNER OF INTERSECTIONWILLIAMS AVE S & HOUSER WY SSIDEWALK CLOSED CROSS HERELIMITSPEEDR2-125RYAN KETTELLSID: P101KMTCS#: 012654EXPIRES: 11/30/24COMMUNICATIONSTRAFFIC CONTROL PLAN NOTES1.ADJACENT BUSINESSES AND/OR RESIDENT'SWILL BE NOTIFIED IN WRITING 48 HRS INADVANCE OF PLACEMENT OF "NO PARKING"SIGNS.2.IF/WHEN UPO TAKES CONTROL OFINTERSECTION, LIGHTS SHALL BE SET TO REDFLASHING MODE. NOTIFICATION IS REQUIREDAT A MIN OF 10 DAYS PRIOR TO WORK.S 3RD ST & WILLIAMS AVE S [PROPOSED WORK: UNDERGROUND]CONTROL TYPE: (LANE CLOSURE / PEDESTRIAN WITH SPOTTERS)ROADWORKAHEADROADWORKAHEADLIMITSPEEDR2-125MFP22002001 FOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCFOCFOC FOC FO C FOC FOC FOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOCFOCFOCFOCFOC FOC FOCFOC FOCFOCFOCFOCFOCFOCSWSWSWSWSWSW SW SWSWSWSWSW SWSWSWSWSWSWSWSWSW SWSW SW SW SW SWSWSWSWSW SWSWSWSWSW SW SW SWSWSWSWSWSW SW SW SWSWSW SW SWSW SWSW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW WELLS AVE S WELLS AVE SS 3RD ST (SR 900)S 3RD ST (SR 900)S 3RD ST (SR 900)WILLIAMS AVE S WILLIAMS AVE S WELLS AVE S WILLIAMS AVE S HOUSER WY SONE WAYDBDBDBBURNETTE AVE S BURNETTE AVE S BURNETTE AVE SBURNETTE AVE S WILLIAMS AVE S WELLS AVE S LOGAN AVE SLOGAN AVE S FOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC?DB DBDBDBS 3RD ST (SR 900)S 3RD ST (SR 900)801 S 3RD ST RENTON 801 S 3RD ST RENTON, WA 98057 RENTON, WA 98057 JB0000966663REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSRPKREV 107/05/22ENTITY REV REQRPKREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-37/5/22ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURESWILL CONFORM TO SPECIFICATIONS STATED IN THEFEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROLDEVICES (M.U.T.C.D)CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSOADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROLWITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OFTHE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF ANDANY SPECIAL CONDITIONS EXISTSITE-SPECIFIC TRAFFIC CONTROL PLANSITE NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDE WALK TO REMAIN OPEN. (PEDESRIAN PATH PROVIDED WHERE REQUIRED) AND WILLBE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED.N3LEFTLANECLOSEDAHEADROADWORKAHEADXXXONE WAYLEFTLANECLOSEDAHEADROADWORKAHEADXXXROADWORKAHEADROADWORKAHEADLIMITSPEEDR2-125SIDEWALK CLOSEDCROSS HERE3ROADWORKAHEADROADWORKAHEADROADWORKAHEADROADWORKAHEADLIMITSPEEDR2-125LIMITSPEEDR2-125POLICEPOLICE DETOURDETOURWORK AREALIMITSPEEDR2-125NOPARKINGFROMTOTOW-AWAY AREA RCW 46 55 113NOPARKINGFROMTOTOW-AWAY AREA RCW 46 55 113SIDEWALK CLOSED CROSS HERE RYAN KETTELLSID: P101KMTCS#: 012654EXPIRES: 11/30/24COMMUNICATIONSTRAFFIC CONTROL PLAN NOTES1.ADJACENT BUSINESSES AND/OR RESIDENT'SWILL BE NOTIFIED IN WRITING 48 HRS INADVANCE OF PLACEMENT OF "NO PARKING"SIGNS.2.IF/WHEN UPO TAKES CONTROL OFINTERSECTION, LIGHTS SHALL BE SET TO REDFLASHING MODE. NOTIFICATION IS REQUIREDAT A MIN OF 10 DAYS PRIOR TO WORK.S 3RD ST & WILLIAMS AVE S [PROPOSED WORK: UNDERGROUND]CONTROL TYPE: (LANE CLOSURE / PEDESTRIAN WITH SPOTTERS)FASLIMITSPEEDR2-125MFP22002001 SEFNCOCOMMUNICATIONSUNDERGROUND COAX INSTALLATIONCOMCAST801 S 3RD ST RENTON801 S 3RD ST RENTON, WA 98057JB0000966663MFP22002001 © 2022 Microso ft Corporation © 2022 TomTom DB DBDB DB DB DBTRENCH 801 S 3RD ST RENTON 801 S 3RD ST RENTON, WA 98057 RENTON, WA 98057 JB0000966663REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSRPKREV 107/05/22ENTITY REV REQRPKPG#SHEET INDEX1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5SITE-PLAN6SITE PHOTOS7STANDARD DETAILS8RENTON STANDARD PLAN 1018DECRIPTION OF WORKTOTALBORE (2) 2" CONDUITS W/ .625 COAX284LFTOTAL:284LFVICINITY MAP 7/5/22PERMITTINGASHLEY KIEHN253-999-22714610 TACOMA AVESUMNER, WA 98390ASKIEHN.SEFNCO.COMCONTACTSSEFNCO OPEDIANE NICAISE4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 389-0920EMAIL: DINICAISE@SEFNCO.COMSEFNCO CONSTRUCTION SUPERVISORANTHONY BRENNAN4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 545-1810EMAIL: ANBRENNAN@SEFNCO.COMVICINITY MAPVICINITY MAPSTA. 10+00'811 S 3RD STRENTON, WASTA. 00+00'801 S 3RD STRENTON, WAENDBEGINNTSN2MFP22002001 801 S 3RD ST RENTON 801 S 3RD ST RENTON, WA 98057 RENTON, WA 98057 JB0000966663REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSRPKREV 107/05/22ENTITY REV REQRPK8REVISIONSDATEDESCRIPTIONINITIALGENERAL NOTES 7/5/22GENERAL NOTESTHE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBYDISCLAIMS ANY RESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION.PERSONS WORKING IN THE AREA COVERED BY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THE LOCATION OF UNDERGROUND UTILITIES PRIOR TOPERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OREXCEED SITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THELOCAL JURISDICTION REGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERETHERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLESTANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OREASEMENTS MAY REQUIRE INSPECTED AND APPROVED BY THE LOCAL JURISDICTION INSPECTOR.INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BE PROVIDED BY DESIGNEE OFPROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OFEXISTING UTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITYCOMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION ISNOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THELOCAL UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUESTEXACT FIELD LOCATIONS OF EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENTLOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTS AND AT POTENTIALUTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALLEXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALLAPPLICABLE AGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTORAT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTH DISTURBING ACTIVITY ORCONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALLUTILITY COMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIESDURING CONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION,AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FORCONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OFTHE APPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS ANDEXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOTLIMITED TO: EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THECONTRACTOR, HIS SUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE ASITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALLCONTACT THE ENGINEER IMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OFSAID STANDARD, UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THECONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITHM.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THERIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFICCONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION APRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCAL JURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FORTHE COMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS ORDESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESSSPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYSFREE AND CLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OFRECORD DRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCALJURISDICTION INSPECTOR AT ALL TIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FORADDITIONAL INFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THERECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BEMAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBEDAREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCALJURISDICTION ENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTUREOR RUNNING OF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANYOTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVEDBY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TODIGGING.18.ALL NEW ANCHORS WILL BE 1" X 7' MANTA RAY ANCHORS.19.ALL NEW ANCHORS WILL BE PLACED WITH A MINIMUM LEAD LENGTH EQUAL TO OR GREATER THANA 3 TO 1 RATIO.20.NO CROSS DRILLING WITHIN 3" OF EXISTING HOLES.21.ALL NEW ATTACHMENTS SHALL BOND TO MGN WHERE REQUIRED.·HOAHEIGHT OF ATTACHMENT·FGAFIBER GLASS ARM·WAWOOD ARM·AAALLEY ARM·MAMETAL (SEATTLE) ARM·CACOMPOSITE (PUPI) ARM·TOPTOP OUTSIDE POSITION·TIPTOP INSIDE POSITION·BOPBOTTOM OUTSIDE POSITION·BIPBOTTOM INSIDE POSITION·FSFIELD SIDE·RSROAD SIDE·DEDEAD END ATTACHMENT·FDEFALSE DEAD END ATTACHMENT·OHGOVERHEAD GUY·IMINTEGRATED MESSENGER·SLMASTREET LIGHT MAST ARM·DLDRIP LOOP·(E)EXISTING·(P)PROPOSEDABBREVIATIONSTRAFFIC CONTROL GENERAL NOTES1.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2.SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 5' PATHCANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACEOF CURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY ASPOTTER TO ENSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED. ASPOTTER SHALL NOT DIRECT TRAFFIC.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE.4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINESFOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THEON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST.6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED, IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILEPASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHENSCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART COMMENCE WORK.NTS3MFP22002001 801 S 3RD ST RENTON 801 S 3RD ST RENTON, WA 98057 RENTON, WA 98057 JB0000966663REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSRPKREV 107/05/22ENTITY REV REQRPK8REVISIONSDATEDESCRIPTIONINITIALLEGEND 7/5/22LEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERPOWERPARCEL LINERIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILSDSDWWSSSSGGTTEOPFOCRWRWBUILDING OUTLINEPFOG LINESIDEWALKSWTRENCHDIRECT BOREPROPOSED AERIAL STRAND PROOF/PULLPROPOSED OVERLASHMINOR ARTERIALCOLLECTOR ARTERIALINTERSTATE FREEWAYACCESS STREETPRINCIPAL ARTERIALBUILDINGR/WWARNING SIGN PLACEMENT (W/ PART #)TRAFFIC BARRELHYDRO-VAC TRENCHKEEPRIGHTREGULATORY SIGN (W/ PART #)LIMITSPEEDR2-125SPEED LIMIT CALLOUTSIGN PLACEMENT / DIRECTIONTRAFFIC CONEFLAGGER STATIONFLAGGER STATIONPATROL CARUNIFORMED POLICE OFFICERWORKVEHICLEWORK VEHICLEFENCESTREET LIGHT HANDHOLETELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALSTREET LIGHT POLETRAFFIC SIGNAL HANDHOLECATV MANHOLECATV HANDHOLECATV PEDESTALTRAFFIC SIGNAL POLESTORM MANHOLEWATER VALVEWATER METERWATER MANHOLETELECOM PEDESTALSTORM INLETSTORM DISCHARGE POINTSTORM DRAIN UNKNOWN WATER UNKNOWNWATER VAULTWATER RESERVOIRD?SEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?STORM DRAIN VAULT SEWER CLEANOUTSEWER MANHOLESCSEWER CATCH BASIN SSSTORM ACCESS POINTBASE LAYERSEXISTING UTILITIESROAD HATCH CLASSIFICATIONROW WORK LINETYPECOMCAST UNDERGROUND SYMBOLSEXISTING UTILITY SYMBOLSTRAFFIC CONTROL SYMBOLSSTORM CATCH BASIN TRAFFIC SIGNAL VAULTGAS METERWATER FITTINGPEDESTAL UNK UTILITYFIRE HYDRANTGAS VALVEGAS TEST POINTGAS MANHOLECONDUIT BEND (MISC)GGGWATER AIR CONTROL VALVEWATER WELLWATER SAMPLING STATIONPOWER HANDHOLEPOWER MANHOLEPOWER CABINETPOWER VAULTPOWER PEDESTALPOWER UNKNOWN P?SIGN POSTCULVERTTRANSIT STOPDRIVEWAY (FOC OR EOP)SS(P) FIBER & COUNTF48(P) .625 COAX(P) .875 COAXCOMCAST AERIAL SYMBOLS(E) FIBER & COUNTF48(E) .625 COAX(E) .875 COAXSLSLTSTSTSTSCCCTTTTWWTS?FWELLWTREE TRIMLIGHT/MEDIUM/HEAVY//WRECKOUTVAULTSPLICE CASEMANHOLEPEDESTALPPPAMINIBRIDGERTTTAATAPAMPLIFER POTHOLEBORE PIT / EXCAVATIONMMMPROPOSEDEXISTINGWRECKOUTNODEABCDABCDABCDSTORAGE LOOPX'X'W?LIT INTERSECTIONFLASHING ARROWSEQUENTIAL ARROWSEQUENTIAL CHEVRONFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONORFLASHING DIAMOND CAUTIONARROWBOARD PLACEMENT (SEE BELOW)CHANNELIZING DEVICES / MIN DIMENSIONSNOTE(S):1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE, LEGIBILITYDISTANCE, NUMBER OF ELEMENTS AND OTHERSPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OF ARROWHEADEQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVE SOLIDRECTANGULAR APPEARANCES. A TYPE D ARROW BOARDSHALL CONFORM TO THE SHAPE OF THE ARROW.ARROWBOARD TYPE MIN LEGIBILITYDISTANCEMIN SIZE MINIMUM# OFELEMENTSABCD48"×24"60"×30"96"×48"NONE12 MILE1 MILE34 MILE12 MILE121315125FT MIN4FT MIN8-12"45°TYPE 3 BARRICADE3FT MIN45°2FT MIN8-12"TYPE 1 BARRICADE3FT MIN8-12"2FT MIN45°TYPE 2 BARRICADE3-4"6"2"4"28'-36" MAXSPEED < 45MPHNIGHT AND/OR FREEWAYMORE THAN 36"4-6" TYPCONECONESPEED ≥ 45MPHDIRECTION INDICATOR BARRICADE12"8"36" MIN 24" MIN45°UNLIT INTERSECTIONDBTRENCHAVAC-TSPOTTER STATIONALL TRAFFIC CONTROL DEVICES / ANNOTATIONS PER MUTCDATSPPPPPPPSISDSDSDSDANCHORSIDEWALK ANCHOR & GUYCOMCAST AERIAL SYMBOLSPROPOSEDEXISTINGWRECKOUTPOLE W/O RISERRISERARMVERTICAL GROUNDSLACK SPANOVERHEAD GUYTANGENT ATTACHMENTDEAD-ENDDOUBLE DEAD-ENDNTS4MFP22002001 FOCFOCFOCFOCFOCFOCFOC SW SWSWSWSW SWSWS 3RD ST (SR 900)WILLIAMS AVE S R/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/W R/W R/W 801306811800808810WSDSDSDSDSDSDSDSS SSPTPGG G GWWW WWWWWWWWWWWWWWWWWWWWT TSS SSTTT TPPPDBDBDB102'P P 47' 56'79'P811WILLIAMS AVE S SLPW SLPPSL PPTTTP?SLPPPPSDSDSDSDSDSDPPPFF SDSDSDSDDB DBDBTRENCH SDP801 S 3RD ST RENTON 801 S 3RD ST RENTON, WA 98057 RENTON, WA 98057 JB0000966663REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSRPKREV 107/05/22ENTITY REV REQRPK8REVISIONSDATEDESCRIPTIONINITIALSITE PLAN 7/5/22SITE PLAN CONSTRUCTION NOTES1POTHOLE: 2'×2' WINDOW TYP2BORE PIT: 3'×5' TYP3BORE AND PLACE (2) 2" SCH 80CONDUITS, WITH .625 COAX, ATA MIN DEPTH OF 36" TYP.4TRENCH AND PLACE (2) 2" SCH80 CONDUITS, WITH .625 COAX,AT A MIN DEPTH OF 36" TYP.SPECIAL PROVISIONS:1.POTHOLES SHALL BE 2'×2'WINDOW TYP PER CITY OFRENTON STANDARDS.2.ALL NEW CONDUITPLACEMENTS IN ROW SHALL BESCH 80 OR EQUIVALENT.3.TRENCHING REQUIRED ATCROSSING.4.ALL RESTORATION SHALL BE PERCITY OF RENTON STANDARDS.N(E) VAULT-1BEGIN ROW DESIGN21(E) VAULT-2END ROW DESIGN223133'3'76'4' TYP FENCEDGARDEN510' HISTORICBELL SOUTHMANHOLENOTE: RESTORATION SHALLBE REQUIRED TO MATCHEXISTING SAWCUT LINES.4MFP22002001 801 S 3RD ST RENTON 801 S 3RD ST RENTON, WA 98057 RENTON, WA 98057 JB0000966663REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSRPKREV 107/05/22ENTITY REV REQRPK86SITE PHOTOS 7/5/22NTSSITE PHOTOSS WILLIAMS ST LOOKING NW56'SITE PLAN CONSTRUCTION NOTES1POTHOLE: 2'×2' WINDOW TYP2BORE PIT: 3'×5' TYP3BORE AND PLACE (2) 2" SCH 80CONDUITS, WITH .625 COAX, ATA MIN DEPTH OF 36" TYP.4TRENCH AND PLACE (2) 2" SCH80 CONDUITS, WITH .625 COAX,AT A MIN DEPTH OF 36" TYP.356'59'47'23 (E) VAULT BEGIN DESIGN23122'122' (E) VAULT-2END DESIGN232 (E) VAULT-222242259'47'56' 122'47'423122'3247'47'120'47'424342 (E) VAULT-2S WILLIAMS ST LOOKING SES WILLIAMS ST LOOKING SES 3RD ST LOOKING SES 3RD ST LOOKING NS 3RD ST LOOKING ES 3RD ST LOOKING WS 3RD ST LOOKING NES 3RD ST LOOKING SE59'34MFP22002001 801 S 3RD ST RENTON 801 S 3RD ST RENTON, WA 98057 RENTON, WA 98057 JB0000966663REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSRPKREV 107/05/22ENTITY REV REQRPK87GENERAL NOTES 7/5/22NTSSTANDARD DETAILSTYPICAL POT HOLE REPAIR DETAILTYPICAL POTHOLE FOR DESIGN &CONSTRUCTION DETAILTYPICAL BORE PIT DETAILEVACUATION FOR HANDHOLES WILL ALSOBE USED FOR BORE / RECEIVING PITS WHENPRACTICAL TO MINIMIZE DISTURBANCE.PROTECT NEARBY DOWNSTREAM STORM DRAININLETS FROM POTENTIAL CONTAMINATION DUE TOCONSTRUCTION. SEE SHEET "BMP" FOR EXAMPLE OFTYPICAL INLET PROTECTION MEASURES.ASPHALT / CONCRETE PATCH-DEPTH TO MATCHEXISTINGTEE TYPE PATCH5'3'ACTUAL DIMENSIONS MAY VARYDEPENDING ON FIELD CONDITIONS.VACUUM SLURRY FROM BORING OPERATIONSAS NEEDED TO ELIMINATE SEE PAGEINTO STREETS AND DRAINS.48"36"11 1/4"BORE @ PAVEMENT2"36"38"(1)-2" HDPEGRADEPAVEMENTTYP BORE PIT DETAILSTYP POTHOLE DETAILSTYP UTILITY XING DETAILSMFP22002001 801 S 3RD ST RENTON 801 S 3RD ST RENTON, WA 98057 RENTON, WA 98057 JB0000966663REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSRPKREV 107/05/22ENTITY REV REQRPK8REVISIONSDATEDESCRIPTIONINITIAL8RENTON STANDARD PLAN 1017/5/22NTSMFP22002001