HomeMy WebLinkAboutEx10_Lighting_Schematic_Design_PlansPROJECT LOCATION 4350 LAKE WASHINGTON BLVD N RENTON, WA 98056 PROJECT ADDRESS LOCATION / SITE MAP SCALE: NOT TO SCALE LIGHTING a WALL SWITCH -SUBSCRIPT INDICATES: 3 = 3-WAY 4 = 4-WAY LV = LOW-VOLTAGE NS = NIGHT SETBACK a = LOWER CASE LETTERS INDICATES SWITCHING GROUP DESIGNATION T = TIMER OS = OCCUPANCY SENSOR a DIMMER SWITCH DAYLIGHT SENSOR OCCUPANCY SENSOR, CEILING MOUNTED OCCUPANCY SENSOR, WALL MOUNTED F1 6a, b LIGHT FIXTURE, SIZES VARY. REFER TO FIXTURE TYPE. TYPICAL ALL FIXTURES: ADJACENT NUMBER INDICATES CIRCUIT GROUPING LOWER CASE LETTER INDICATES SWITCHING GROUP FIXTURE ON EMERGENCY CIRCUIT SIZE VARIES, REFER TO FIXTURE TYPE. WALL-MOUNTED FIXTURE SIZE VARIES, REFER TO FIXTURE TYPE. WALL MOUNTED FIXTURE ON EMERGENCY CIRCUIT. SIZE VARIES, REFER TO FIXTURE TYPE. STRIP FIXTURE SIZE VARIES, REFER TO FIXTURE TYPE. STRIP FIXTURE ON EMERGENCY CIRCUIT SIZE VARIES, REFER TO FIXTURE TYPE. DOWNLIGHT ON EMERGENCY CIRCUIT ,STEP LIGHTS PENDANT LIGHT ILLUMINATED EXIT SIGN -FACES & DIRECTION OF ALL ARROWS AS SHOWN, WHERE INDICATED TRACK LIGHTING, LENGTH AS INDICATED TROFFER SURFACE DOWNLIGHT LINEAR PENDANT LINEAR WALL WASH RECESSED DOWNLIGHT FIXTURE RECESSED WALL WASH/ADJUSTABLE FIXTURE , , WALL SCONCE, SURFACE WALL WASH/ADJUSTABLE DOWNLIGHT DS OS OS C 2020 HENSLEY LAMKIN RACHEL, INC. DOCUMENTS AS INSTRUMENTS OF SERVICE ARE GIVEN IN CONFIDENCE AND REMAIN THE PROPERTY OF HENSLEY LAMKIN RACHEL, INC. THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT WRITTEN CONSENT OF HENSLEY LAMKIN RACHEL, INC. Site Plan Submittal: Construction Set Issue: Drawing No. Project ID HENSLEY LAMKIN RACHEL, INC. DALLAS ●HOUSTON ● SEATTLE WWW.HLRINC.NET PH:972.726.9400 Project Title: PROJECT MGR: DRAWN BY: CHECKED BY: REVISIONS Permit Issue:NOT FOR CONSTRUCTION07.01.2021 20485 Designer Author Checker KENNYDALE GATEWAY RENTON, WASHINGTON E0.0 LIGHTING LEGENDS AND ABBREVIATIONS LIGHTING SHEET INDEX SHEET NUMBER SHEET NAME SHEET SCALE MASTER SITE PLAN 6/7/2021 E0.0 LIGHTING LEGENDS AND ABBREVIATIONS NTS X EL0.1 LUMINAIRE SCHEDULE & SEQUENCE OF OPERATIONS NTS X EL3.0 SITE PLAN - LIGHTING 1" = 30'-0" X EXHIBIT 10 RECEIVED Clark Close 12/17/2021 PLANNING DIVISION DocuSign Envelope ID: AB259DAD-E1F4-4927-9B6D-D48F19435899 C 2020 HENSLEY LAMKIN RACHEL, INC. DOCUMENTS AS INSTRUMENTS OF SERVICE ARE GIVEN IN CONFIDENCE AND REMAIN THE PROPERTY OF HENSLEY LAMKIN RACHEL, INC. THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT WRITTEN CONSENT OF HENSLEY LAMKIN RACHEL, INC. Site Plan Submittal: Construction Set Issue: Drawing No. Project ID HENSLEY LAMKIN RACHEL, INC. DALLAS ●HOUSTON ● SEATTLE WWW.HLRINC.NET PH:972.726.9400 Project Title: PROJECT MGR: DRAWN BY: CHECKED BY: REVISIONS Permit Issue:NOT FOR CONSTRUCTION07.01.2021 20485 Designer Author Checker KENNYDALE GATEWAY RENTON, WASHINGTON EL0.1 LUMINAIRE SCHEDULE & SEQUENCE OF OPERATIONS E3 40INCH TALL BOLLARD, 360DEG GENERAL PATHWAYS FORMS + SURFACES LBHL0-603-3000K-360 LED, 3000K, 80+ CRI 424LM 40W 120-277V INTEGRAL, ELECTRONIC 0-10V 6"DIA X 40"H DARK GREY 1. BUG RATING - B0-U1-G0 E2 20FT TALL POST TOP LUMINAIRE WITH 3FT MOUNTING ARM, TYPE V DISTRIBUTION ROADWAY & PARKING LUMCA LUMINAIRE: LIO-M-SM-A-0-5-01-36LED05-530MA-60W-120 V-L5S-30K-C80-SG MOUNTING ARM: PM5-CF80-36 POLE: AP05-20-WB9-SG-ANCHOR BOLTS LED, 3000K, 80+ CRI 6716LM 60W 120-277V INTEGRAL, ELECTRONIC 0-10V - STEEL GREY 1. BUG RATING - B3-U0-G1 2. BOTTOM OF LUMINAIRE TO BE AT 17FT 3. STRUCTURAL ENGINEER TO VERIFY ANCHOR BOLT LENGTHS AND OVERALL POLE ASSEMBLY ARE APPROPRIATE FOR EPA WIND SPEEDS IN INSTALLATION AREA. E1A 20FT TALL POST TOP LUMINAIRE WITH 3FT MOUNTING ARM, TYPE III DISTRIBUTION WITH HOUSE SIDE SHIELDED OPTICS ROADWAY & PARKING LUMCA LUMINAIRE: LIO-M-SM-A-0-5-01-36LED05-530MA-60W-120 V-L3-30K-C80-SG-HSS MOUNTING ARM: PM5-CF80-36 POLE: AP05-20-WB9-SG-ANCHOR BOLTS LED, 3000K, 80+ CRI 6716LM 60W 120-277V INTEGRAL, ELECTRONIC 0-10V - STEEL GREY 1. BUG RATING - B1-U0-G1 2. BOTTOM OF LUMINAIRE TO BE AT 17FT 3. STRUCTURAL ENGINEER TO VERIFY ANCHOR BOLT LENGTHS AND OVERALL POLE ASSEMBLY ARE APPROPRIATE FOR EPA WIND SPEEDS IN INSTALLATION AREA. E1 20FT TALL POST TOP LUMINAIRE WITH 3FT MOUNTING ARM, TYPE III DISTRIBUTION ROADWAY & PARKING LUMCA LUMINAIRE: LIO-M-SM-A-0-5-01-36LED05-530MA-60W-120 V-L3-30K-C80-SG MOUNTING ARM: PM5-CF80-36 POLE: AP05-20-WB9-SG-ANCHOR BOLTS LED, 3000K, 80+ CRI 6716LM 60W 120-277V INTEGRAL, ELECTRONIC 0-10V - STEEL GREY 1. BUG RATING - B1-U0-G1 2. BOTTOM OF LUMINAIRE TO BE AT 17FT 3. STRUCTURAL ENGINEER TO VERIFY ANCHOR BOLT LENGTHS AND OVERALL POLE ASSEMBLY ARE APPROPRIATE FOR EPA WIND SPEEDS IN INSTALLATION AREA. EXTERIOR LIGHTING TYPE IMAGE DESCRIPTION LOCATION MANUFACTURER PRODUCT NO. LAMP, CCT, CRI LUMENS (DELIVERED) WATTS VOLTAGE DRIVER DIMMING SIZE FINISH NOTES General Notes: 1. Emergency egress lighting to be provided via inverter unless otherwise noted. 2. All luminaire finishes to be verified by owner/architect/interior designer. 3. CCT = Correlated Color Temperature (measured in Kelvin, K) 4. CRI = Color Rendering Index (higher number is better rendering) LUMINAIRE SCHEDULE EXTERIOR LIGHTING ASTRONOMICAL TIME-CLOCK EXTERIOR PHOTOCELL INTELLIGENT CONTROL. NETWORKED FOR ALL EXTERIOR LIGHTING, TIED TO BUILDING LIGHTING HEAD END. DIMMING ACUITY FRESCO TOUCH SCREEN (OR EQUAL) ALL EXTERIOR LIGHTING TO BE DIMMABLE. ALL EXTERIOR LIGHTING TO BE PROVIDED WITH MANUAL ON/OFF CONTROL. ASTRONOMICAL TIME CLOCK AND PHOTOCELL FOR AUTOMATIC EXTERIOR LIGHTING CONTROL. SET TIME CLOCK TO THE FOLLOWING. 30 MIN AFTER SUNRISE: TRIGGER EXTERIOR LIGHTING OFF SCENE. 30 MIN BEFORE SUNSET: TRIGGER EXTERIOR LIGHTING ON SCENE. ALL EXTERIOR LIGHTING TO DIM TO 30% OUTPUT BETWEEN MIDNIGHT AND 6AM. BUILDING FACADE, SITE AND LANDSCAPE LIGHTING WILL REMAIN ON DURING NON-DAYLIGHT HOURS FOR OCCUPANT SAFETY /SECURITY IN 24 HOUR OCCUPIED BUILDING. LOCATE EXTERIOR PHOTOCELL ON ROOF. CONFIRM EXACT SENSOR LOCATION WITH SELECTED LIGHTING CONTROL MANUFACTURER TO ENSURE OPTIMAL PERFORMANCE. PHOTOCELL TO OVERRIDE TIME CLOCK SETTINGS WHEN MINIMAL DAYLIGHT IS DETECTED DURING DARK WEATHER PATTERNS. PROVIDE OVERRIDE SWITCH IN LEVEL 1 ELECTRICAL ROOM FOR ON/OFF OVERRIDE CONTROL OF ALL EXTERIOR LIGHTING. LABEL SWITCH "EXTERIOR LIGHTING OVERRIDE." MANUAL DIMMING CONTROLS FOR SELECT EXTERIOR LIGHTING WILL BE PROVIDED AS DESIGN DEVELOPS. LOCATE DIMMING TOUCH SCREEN IN ELECTRICAL ROOM AT EACH FLOOR LEVEL WHERE EXTERIOR LIGHTING WILL BE DIMMED. LABEL SWITCH WITH EXTERIOR ZONE NAMES. ... SPACE TYPE CONTROL TYPE TOPOLOGY CONTROL SWITCH LIGHTING CONTROL ZONES NOTES 1. ELECTRICAL CONTRACTOR AND SELECTED LIGHTING CONTROL MANUFACTURER TO PROVIDE SHOP DRAWINGS AND WIRING DIAGRAMS BASED ON LIGHTING CONTROL SEQUENCE OF OPERATIONS SCHEDULE. SHOP DRAWINGS SHALL INCLUDE RECOMMENDED QUANTITIES AND LOCATIONS FOR SENSORS, RELAYS, PANELS, SWITCHES, AND OTHER EQUIPMENT REQUIRED TO ACHIEVE CONTROL FUNCTIONS DESCRIBED IN SEQUENCE SCHEDULE. MANUFACTURER RECOMMENDATIONS SHALL SUPERSEDE SENSOR QUANTITIES AND LOCATIONS ILLUSTRATED ON LIGHTING PLANS. 2. LUMINAIRES IN PRIMARY AND SECONDARY DAYLIGHT ZONES TO AUTOMATICALLY DIM FROM 100% POWER TO 15% POWER (MAXIMUM DIMMING THRESHOLD) WHEN PHOTOCELL DETECTS ADEQUATE DAYLIGHT AS DESCRIBED BELOW. BASELINE DESIGNED LIGHT LEVELS SHALL BE DETERMINED BY RECORDING ILLUMINANCE LEVELS WITH ALL LIGHTS ON AT 100% POWER, WITH NO CONTRIBUTING DAYLIGHTING. AUTOMATIC DAYLIGHT DIMMING SHALL OCCUR WHEN LIGHT LEVELS SHALL MEET OR EXCEED BASELINE DESIGN LEVELS AT ALL TIMES OF OCCUPANCY, INCLUDING WHEN LIGHTS ARE DIMMED VIA DAYLIGHT SENSOR. 3. ALL INTELLIGENT CONTROLS SHALL BE DIGITAL AND MAY BE TIED TO A NETWORK BACKBONE AS NOTED IN SEQUENCE SCHEDULE. STANDALONE LIGHTING CONTROLS CAN BE LOW VOLTAGE OR LINE VOLTAGE (AS REQUIRED PER FUNCTIONS IN SCHEDULE) AND ARE NOT TIED TO A NETWORK BACKBONE. 4. ALL LIGHTING CONTROL DEVICES SHALL BE COMPATIBLE WITH TYPES OF DIMMING NOTED IN APPROVED LIGHTING PRODUCT SUBMITTAL PACKAGE. LIGHTING PRODUCT SUBMITTAL SHALL BE APPROVED BY LIGHTING DESIGNER, ARCHITECT /INTERIOR DESIGNER, AND OWNER. 5. PROVIDE UL924 BYPASS RELAY DEVICES FOR ALL DESIGNATED EMERGENCY EGRESS LIGHTING WITH MANUAL OR AUTOMATIC CONTROLS TO ALLOW ILLUMINATION TO RAISE TO FULL OUTPUT DURING AN EVENT OF POWER LOSS. 6. LIGHTING CONTROL PROGRAMMING AND OWNER TRAINING FOR CONTROL SYSTEM SHOULD BE INCLUDED IN CONTRACTOR BASE BID AND NOT BE INCLUDED AS A CHANGE ORDER. 7. CONTRACTOR SHALL SCHEDULE A PRE CONSTRUCTION MEETING TO REVIEW LIGHTING CONTROL SHOP DRAWINGS WITH THE MANUFACTURER AGENT (INCLUDING DESIGNER /ENGINEER - AS NEEDED) PRIOR TO PRODUCT RELEASE. ... GENERAL NOTES LIGHTING CONTROL SEQUENCE OF OPERATIONS DocuSign Envelope ID: AB259DAD-E1F4-4927-9B6D-D48F19435899 RECYCLECHUTEWASTECHUTERECYCLECHUTE WASTECHUTE SSS TRASH STAIR STAIR LOBBY/MAIL RETAIL BIKE STORAGE COURTYARD COURTYARD B1100 1,500 SF A770 A770 A770 A770 S550A665 STAIRSTAIRLOADING STAIR LEASING/LOBBY2,330 SF CLUB 1,874 SF FITNESS 1,468 SF MAIL/PACKAGES1,100 SF STAIRCOURTYARD COURTYARD LOADING AD800 B1100 S550 B1100 S550STAIRLOBBY/MAIL925 SF S550 S550 S550 GARAGEENTRY COVEREDOUTDOORAMENITY HC HC 8 SPACES 6 SPACES 6 SPACES 9 SPACES 7 SPACES5 COMPACTSPACES5 SPACES4 SPACES 18 SPACES 4 SPACES 8 SPACES8 SPACES5 COMPACTSPACES 5 COMPACTSPACES 7 COMPACT SPACES 7 COMPACT SPACES 6 SPACES10 CARPORT SPACES8 CARPORT SPACES6 CARPORT SPACES5 CARPORT SPACES7 COMPACT SPACES 8 COMPACT SPACES A770 A770 A770 STAIR B1100 B1100 A770A770 A770 STAIR HC VAN HC 4 SPACES 4 SPACES GARAGE ENTRYGARAGE ENTRY GARAGE ENTRY GARAGEENTRYMAY CREEK TRAIL CONNECTION 7 SPACES7 SPACES4 SPACES6 SPACESLK. WASHINGTON BLVD.I -405TK - EVOLUTION3500 - SEISMIC 33'-1 1/2"3'-6"8'-8" CLR.6'-11" CLR.TK - EVOLUTION4500 FREIGHT -SEISMIC8'-3" CLR.9'-6 1/2" CLR.1'-1 1/2"4'-6"TK - EVOLUTION4500 FREIGHT - SEISMIC 8'-3" CLR.9'-6 1/2" CLR.1'-1 1/2"4'-6" TK - EVOLUTION3500 - SEISMIC 3 3'-1 1/2" 3'-6" 8'-8" CLR.6'-11" CLR.7707707701100770110011001100 TK - EVOLUTION3500 - SEISMIC 3 3'-1 1/2" 3'-6" 8'-8" CLR.6'-11" CLR.TK - EVOLUTION4500 FREIGHT - SEISMIC 8'-3" CLR.9'-6 1/2" CLR.1'-1 1/2"4'-6"(53)(52)(51)(49)(48)(47)(44)(43)(42)(39)(50)(45)12' CWM W S E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E3 E1A E1A E1A E1 E1 E2 E1E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 A. REFER TO SHEET EL0.1 FOR LUMINAIRE SCHEDULE. B. REFER TO SHEET EL0.1 FOR LIGHTING CONTROL SEQUENCE OF OPERATIONS. C. LIGHTING DRAWINGS TO BE REVIEWED IN CONJUNCTION WITH LUMINAIRE CUT SHEET PACKAGE PROVIDED AS SUPPLEMENT TO DRAWING PACKAGE. GENERAL NOTES: C 2020 HENSLEY LAMKIN RACHEL, INC. DOCUMENTS AS INSTRUMENTS OF SERVICE ARE GIVEN IN CONFIDENCE AND REMAIN THE PROPERTY OF HENSLEY LAMKIN RACHEL, INC. THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT WRITTEN CONSENT OF HENSLEY LAMKIN RACHEL, INC. Site Plan Submittal: Construction Set Issue: Drawing No. Project ID HENSLEY LAMKIN RACHEL, INC. DALLAS ●HOUSTON ● SEATTLE WWW.HLRINC.NET PH:972.726.9400 Project Title: PROJECT MGR: DRAWN BY: CHECKED BY: REVISIONS Permit Issue:NOT FOR CONSTRUCTION07.01.2021 20485 Designer Author Checker KENNYDALE GATEWAY RENTON, WASHINGTON EL3.0 SITE PLAN - LIGHTING 1" = 30'-0"01 SITE PLAN - LIGHTING N FLAG NOTES DocuSign Envelope ID: AB259DAD-E1F4-4927-9B6D-D48F19435899