Loading...
HomeMy WebLinkAboutMFP22002068.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP22002068 IVR Number: 22002068 Permit Information Permit Name: JB0000824-OSP DE T2BD Address/Location:04/20/2022Application Date:8898701290Parcel Number: 1211 S 26TH ST Permit Type:09/27/2022Issue Date:Franchise Permit Work Class:09/27/2023Expiration Date:Major Utility Job Number: JB0000824118Franchise Type:Cable 05/19/2022Finalize Date: Description: CB0000824118 Comcast Proposes to bore and place (2) 2" conduit with 48ct fiber approximately 341'. Overlash 48ct fiber 1076' and place new vault. Pothole all existing utilities. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling Rhonda Resnik Comcast 410 Valley Ave NW, Suite 12, Bldg C Puyallup, WA 98371 B: (253) 864-4246Applicant Ashley Kiehn 4610 Tacoma Avenue Sumner, WA 98390 ApplicantX Carissa Morris Sefnco Communications Applicant Sandra Castro Comcast C: (209) 561-4786Contact Tom Donnelly Comcast Business Communications 1701 Jfk Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact Scott Nall SEFNCO Communications Inc 2904 4th Ave NE Puyallup, WA 98372 B: (877) 385-2903 C: (253) 444-9057 Contractor Business License Number: 41108Construction Contractor: SEFNCCI850QD CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 3/18/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 3/18/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1.Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2.The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: ▪Include map(s) showing the location of the project and work area. ▪Be legible lettering and clear, contrasting, symbols of viewing or printing. ▪Must indicate street names, and north arrow and scale. ▪Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. -Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3.Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering SEFNCO Communications Carissa Morris (253) 313-2057 4610 Tacoma Ave Sumner, WA 98390 9:00am 3:30pm JB0000824118 - OSP DE RN21A CONSTRUCTION 1211 S 26TH ST 10/21/2022 11/21/2022 Comcast propses to bore & place (2) 2" conduit w/ 48ct fiber ~341'; Overlash 48ct fiber ~1076'; Place appropriate storage ~200'; Place new vault. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 3/18/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: • Must have approved Traffic Control Plan (TCP) prior to commencing the work. • Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. • WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • All permit conditions shall be met. NOTES: • Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. • Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. • In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 3/18/2021 • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) R/WR/WR/WR/WSWSW FOCFOCFOCFOCFOCFOCR/WFLFLFL FOCFOCFOCFOCFOCFOCSWSWSWSWSWBENSON RD S←DRIVEWAY→2608 CEDAR AVE S,RENTON, WA 98055, USA2614 CEDAR AVE S,RENTON, WA 98055, USA2620 CEDAR AVE S,RENTON, WA 98055, USA2625 BENSON RD S,RENTON, WA 98055, USA2640 BENSON RD S,RENTON, WA 98055, USADBDBDBDBDBDBDBDBDBDBDB341'56'R/WR/WR/WR/WR/WR/WR/WR/WAAAAAPOLE 1POLE 210'200'T2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2) 1211 S 26TH ST RENTON, WA 98055, USA JB824118REVISIONSDATEDESCRIPTIONINITIALSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:RRCOMCASTSEFNCOCOMMUNICATIONS03/03/22REVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-114ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURESWILL CONFORM TO SPECIFICATIONS STATED IN THEFEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROLDEVICES (M.U.T.C.D)CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSOADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROLWITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OFTHE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF ANDANY SPECIAL CONDITIONS EXIST5+6'016'5MAINTAIN DRIVEWAY ACCESS AT ALL TIMESSIDE WALK TO REMAIN OPEN. 2'&'54+#02#6*2418+&'&9*'4'4'37+4'& AND WILLBE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED.5+6'Ä52'%+(+%64#((+%%10641.2.#0$'05104&5=241215'&914-#'4+#.#0&70&'4)4170&?%10641.6;2' 5*17.&'4%.1574' NXRIGHTSHOULDERCLOSED XSHOULDERWORK ROADWORKAHEADXWORK AREAWORKVEHICLE SPOTTERLIMITSPEEDR2-135SPOTTER Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 FOCFOCFOCFOCFOCFOCFOCFOC FOCSWSWSWSWSWSWSW SW SW SWR/WR/WR/WR/WR/WR/WR/W R/W R/W R/WR/WR/WR/WR/WSWSWSWSWSW SW FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCSW SW SW SW SW SW R/W R/W R/W←DRIVEWAY→S 26TH STCEDAR AVE SBENSON R D S BENSO N R D S 1211 S 26TH ST,RENTON, WA 98055, USA1207 S 26TH ST,RENTON, WA 98055, USAPDBDBDBDBDB341'R/WR/W←DRIVEWAY→T2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2) 1211 S 26TH ST RENTON, WA 98055, USA JB824118REVISIONSDATEDESCRIPTIONINITIALSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:RRCOMCASTSEFNCOCOMMUNICATIONS03/03/22REVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-224ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURESWILL CONFORM TO SPECIFICATIONS STATED IN THEFEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROLDEVICES (M.U.T.C.D)CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSOADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROLWITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OFTHE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF ANDANY SPECIAL CONDITIONS EXIST5+6'016'5MAINTAIN DRIVEWAY ACCESS AT ALL TIMESSIDE WALK TO REMAIN OPEN. 2'&'54+#02#6*2418+&'&9*'4'4'37+4'& AND WILLBE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED.5+6'Ä52'%+(+%64#((+%%10641.2.#0$'05104&5=241215'&914-70&'4)4170&?%10641.6;2' 4+)*6.#0'%.1574'(174Ä.#0'41#&9#; NNOTE:SIDEWALK & ADA FACILITIES TO REMAIN OPEN.PEDESTRIANS MAY BE ESCORTED THROUGH THEWORK ZONE BY SPOTTERS PROVIDED BY THECONTRACTOR.XXRIGHTLANECLOSEDAHEADROADWORKAHEADXX XRIGHTLANECLOSEDAHEAD ROADWORKAHEADXLIMITSPEEDR2-125LIMITSPEEDR2-135WORK A R E A WORKVEHICLESPOTTERSPOTTER Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCR/WR/WR/WR/WR/WR/WR/WFLFLFLFLFLFLFLFLFLFLFLFLFLFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWEOPEOPR/WR/WR/WR/WR/W R/W R/W R/W R/WR/W R/WR/WR/WR/W R/WR/WR/W R/W R/WR/W←DRIVEWAY←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←D R I V E W A Y → 106TH AVE SE ←DRIVEWAY→RENTON, WA 98055, USA16533 BENSON RD S,RENTON, WA 98055, USA16543 BENSON RD S,RENTON, WA 98055, USA16551 106TH AVE SE,RENTON, WA 98055, USA10502 SE 166TH ST,RENTON, WA 98055, USA16550 106TH AVE SE,RENTON, WA 98055, USA1503 S 28TH PL,RENTON, WA 98055, USA2824 108TH AVE SE,RENTON, WA 98055, USA1523 S 28TH ST,RENTON, WA 98055, USA1529 S 28TH ST,RENTON, WA 98055, USA1507 S 28TH ST,RENTON, WA 98055, USA1503 S 28TH ST,RENTON, WA 98055, USA1431 S 28TH ST,RENTON, WA 98055, USA1413 S 28TH ST,RENTON, WA 98055, USA157'162'176'BENSON RD S←DRIVEWAY→SWA A A A A A A A AAAAAAAAAAAAAAR/W POLE 6POLE 7POLE 8 POLE 5← D R I V E W A Y → T2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2) 1211 S 26TH ST RENTON, WA 98055, USA JB824118REVISIONSDATEDESCRIPTIONINITIALSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:RRCOMCASTSEFNCOCOMMUNICATIONS03/03/22REVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-334ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURESWILL CONFORM TO SPECIFICATIONS STATED IN THEFEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROLDEVICES (M.U.T.C.D)CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSOADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROLWITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OFTHE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF ANDANY SPECIAL CONDITIONS EXIST5+6'016'5MAINTAIN DRIVEWAY ACCESS AT ALL TIMESSIDE WALK TO REMAIN OPEN. 2'&'54+#02#6*2418+&'&9*'4'4'37+4'& AND WILLBE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED.5+6'Ä52'%+(+%64#((+%%10641.2.#0$'05104&5=241215'&914-#'4+#.?%10641.6;2' 10'.#0'691Ä9#;64#((+%%10641.9+6*(.#))'45 NFLAGGERSPOTTERXX ONELANEROADAHEADROADWORKAHEADX FLAGGERXXONELANEROADAHEADROADWORKAHEADXLIMITSPEEDR2-125LIMITSPEEDR2-135WORK AREAXXON ELAN E RO A D AH E A D RO A D WO R K AH E A D XFL A G G E R LI M I T SPE E D R2- 1 35 Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 FOCFOCFOCFOCFOCR/WR/WR/WR/WR/WFLFLFLFLFLFLFOCFOCSWEOPEOPR/WR/WR/WR/WR/WEOP EOPEOPR/WR/WR/WR/WR/WR/WR/W R/W R/W R/WR/W←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→ ← D R I V EW A Y →106TH AVE SESE 166TH ST←DRIVEWAY→16551 106TH AVE SE,RENTON, WA 98055, USA10502 SE 166TH ST,RENTON, WA 98055, USA16561 106TH AVE SE,RENTON, WA 98055, USA16550 106TH AVE SE,RENTON, WA 98055, USA16602 106TH AVE SE,RENTON, WA 98055, USA16606 106TH AVE SE,RENTON, WA 98055, USA10525 SE 166TH ST,RENTON, WA 98055, USA10517 SE 166TH ST,RENTON, WA 98055, USA10509 SE 166TH ST,RENTON, WA 98055, USA16617 106TH AVE SE,RENTON, WA 98055, USA16612 106TH AVE SE,RENTON, WA 98055, USA16605 BENSON RD S,RENTON, WA 98055, USA16607 BENSON RD S,RENTON, WA 98055, USA176'BENSON RD S←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→SW←DRIVEWAY→A A A A A A A R/W POLE 8 106TH AVE SE T2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2) 1211 S 26TH ST RENTON, WA 98055, USA JB824118REVISIONSDATEDESCRIPTIONINITIALSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:RRCOMCASTSEFNCOCOMMUNICATIONS03/03/22REVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLAN-444ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURESWILL CONFORM TO SPECIFICATIONS STATED IN THEFEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROLDEVICES (M.U.T.C.D)CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSOADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROLWITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OFTHE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF ANDANY SPECIAL CONDITIONS EXIST5+6'016'5MAINTAIN DRIVEWAY ACCESS AT ALL TIMESSIDE WALK TO REMAIN OPEN. 2'&'54+#02#6*2418+&'&9*'4'4'37+4'& AND WILLBE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED.5+6'Ä52'%+(+%64#((+%%10641.2.#06*#8'5'=241215'&914-#'4+#.?%10641.6;2' 10'.#0'691Ä9#;64#((+%%10641.9+6*(.#))'45 NFLAGGERWORKAREASPOTTERXX ONELANEROADAHEADROADWORKAHEADX FLAGGERX XONELANEROADAHEAD ROADWORKAHEADXFLAGGERXXONELANEROADAHEADROADWORKAHEADX LIMITSPEEDR2-125LIMITSPEEDR2-125LIMITSPEEDR2-125 Morgan DavidsonID: D231N2TCS# 012798EXPIRES: 5/2025 SEFNCOCOMMUNICATIONSPROPOSED AERIAL AND UNDERGROUND FIBER INSTALLATIONCOMCASTT2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2)1211 S 26TH ST, RENTON, WA 98055, USAJB# 824118 DBDBDBAAAAAAAAAAASHEET INDEXPG #DESCRIPTION OF WORKTOTALCONTACTST2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2) 1211 S 26TH ST RENTON, WA 98055, USA JB824118REVISIONSDATEDESCRIPTIONINITIALSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:RRCOMCASTSEFNCOCOMMUNICATIONS03/03/22VICINITY MAP72VICINITY MAPPERMITTINGASHLEY KIEHN4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 999-2271EMAIL: ASKIEHN.SEFNCO.COMSEFNCO CONSTRUCTION MANAGERCOMCASTSEFNCO OPEBRANDON MORRIS410 TACOMA AVESUMNER, WA 98390PHONE:253-306-1908EMAIL: BRANDONMORRIS@SEFNCO.COMBARBARA MARTIN410 VALLEY AVEPUYALLUP, WA 98371PHONE: (253) 864-4246EMAIL: BARBARA_MARTIN2@COMCAST.COMENDSTA. A 03+411211 S 26TH ST,RENTON, WA 98055ENDSTA. B 10+7616602 106TH AVE SE,RENTON, WA 98055NTSN1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5-7SITE-PLANSTEVE HARSHFIELD4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 266-4741EMAIL: STHARSHFIELD@SEFNCO.COMBEGINSTA. A 00+002705 108TH AVE SE,RENTON, WA 98055STA. B 00+00BORE AND PLACE 2(2") CONDUIT WITH 48CT FIBER341LFOVERLASH 48CT FIBER1076LFPLACE APPROPRIATE STORAGE200LFPLACE NEW VAULTTOTAL:1617LF T2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2) 1211 S 26TH ST RENTON, WA 98055, USA JB824118REVISIONSDATEDESCRIPTIONINITIALSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:RRCOMCASTSEFNCOCOMMUNICATIONS03/03/227REVISIONSDATEDESCRIPTIONINITIAL3GENERAL NOTES NTSGENERAL NOTESTHE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBYDISCLAIMS ANY RESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION.PERSONS WORKING IN THE AREA COVERED BY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THE LOCATION OF UNDERGROUND UTILITIES PRIOR TOPERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OREXCEED SITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THELOCAL JURISDICTION REGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERETHERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLESTANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OREASEMENTS MAY REQUIRE INSPECTED AND APPROVED BY THE LOCAL JURISDICTION INSPECTOR.INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BE PROVIDED BY DESIGNEE OFPROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OFEXISTING UTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITYCOMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION ISNOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THELOCAL UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUESTEXACT FIELD LOCATIONS OF EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENTLOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTS AND AT POTENTIALUTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALLEXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALLAPPLICABLE AGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTORAT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTH DISTURBING ACTIVITY ORCONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALLUTILITY COMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIESDURING CONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION,AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FORCONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OFTHE APPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS ANDEXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOTLIMITED TO: EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THECONTRACTOR, HIS SUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE ASITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALLCONTACT THE ENGINEER IMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OFSAID STANDARD, UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THECONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITHM.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THERIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFICCONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION APRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCAL JURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FORTHE COMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS ORDESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESSSPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYSFREE AND CLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OFRECORD DRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCALJURISDICTION INSPECTOR AT ALL TIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FORADDITIONAL INFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THERECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BEMAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBEDAREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCALJURISDICTION ENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTUREOR RUNNING OF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANYOTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVEDBY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TODIGGING.18.ALL NEW ANCHORS WILL BE 1" X 7' MANTA RAY ANCHORS.19.ALL NEW ANCHORS WILL BE PLACED WITH A MINIMUM LEAD LENGTH EQUAL TO OR GREATER THANA 3 TO 1 RATIO.20.NO CROSS DRILLING WITHIN 3" OF EXISTING HOLES.21.ALL NEW ATTACHMENTS SHALL BOND TO MGN WHERE REQUIRED.·HOAHEIGHT OF ATTACHMENT·FGAFIBER GLASS ARM·WAWOOD ARM·AAALLEY ARM·MAMETAL (SEATTLE) ARM·CACOMPOSITE (PUPI) ARM·TOPTOP OUTSIDE POSITION·TIPTOP INSIDE POSITION·BOPBOTTOM OUTSIDE POSITION·BIPBOTTOM INSIDE POSITION·FSFIELD SIDE·RSROAD SIDE·DEDEAD END ATTACHMENT·FDEFALSE DEAD END ATTACHMENT·OHGOVERHEAD GUY·IMINTEGRATED MESSENGER·SLMASTREET LIGHT MAST ARM·DLDRIP LOOP·(E)EXISTING·(P)PROPOSEDABBREVIATIONSTRAFFIC CONTROL GENERAL NOTES1.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2.SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 5' PATHCANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACEOF CURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY ASPOTTER TO ENSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED. ASPOTTER SHALL NOT DIRECT TRAFFIC.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE.4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINESFOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THEON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST.6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED, IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILEPASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHENSCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART COMMENCE WORK. T2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2) 1211 S 26TH ST RENTON, WA 98055, USA JB824118REVISIONSDATEDESCRIPTIONINITIALSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:RRCOMCASTSEFNCOCOMMUNICATIONS03/03/2274LEGEND NTSLEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERPOWERPARCEL LINERIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILSDSDWWSSSSGGTTLIPD/LEOPFOCRWRWBUILDING OUTLINEPFLFOG LINESIDEWALKSWSWTRENCHDIRECT BOREPROPOSED AERIAL STRAND PROOF/PULLPROPOSED OVERLASHMINOR ARTERIALCOLLECTOR ARTERIALINTERSTATE FREEWAYACCESS STREETPRINCIPAL ARTERIALBUILDINGR/WWARNING SIGN PLACEMENT (W/ PART #)TRAFFIC BARRELHYDRO-VAC TRENCHKEEPRIGHTREGULATORY SIGN (W/ PART #)LIMITSPEEDR2-125SPEED LIMIT CALLOUTSIGN PLACEMENT / DIRECTIONTRAFFIC CONEFLAGGER STATIONFLAGGER STATIONPATROL CARUNIFORMED POLICE OFFICERWORK VEHICLEFENCESTREET LIGHT HANDHOLETELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALSTREET LIGHT POLETRAFFIC SIGNAL HANDHOLECATV MANHOLECATV HANDHOLECATV PEDESTALTRAFFIC SIGNAL POLESTORM MANHOLEWATER VALVEWATER METERWATER MANHOLETELECOM PEDESTALSTORM INLETSTORM DISCHARGE POINTSTORM DRAIN UNKNOWN WATER UNKNOWNWATER VAULTWATER RESERVOIRD?SISEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?STORM DRAIN VAULT SDSEWER CLEANOUTSEWER MANHOLESCSEWER CATCH BASIN SSSTORM ACCESS POINTBASE LAYERSEXISTING UTILITIESROAD HATCH CLASSIFICATIONROW WORK LINETYPECOMCAST UNDERGROUND SYMBOLSEXISTING UTILITY SYMBOLSTRAFFIC CONTROL SYMBOLSSTORM CATCH BASIN SDTRAFFIC SIGNAL VAULTGAS METERTEST VALVEPEDESTAL UNK UTILITYFIRE HYDRANTGAS VALVEGAS TEST POINTGAS MANHOLEWATER PUMPGGGWATER AIR CONTROL VALVEWATER WELLWATER SAMPLING STATIONPOWER HANDHOLEPOWER MANHOLEPOWER CABINETPOWER VAULTPOWER PEDESTALPPOWER UNKNOWN PPPPPP?SIGN POSTCULVERTTRANSIT STOPDRIVEWAY (FOC OR EOP)SDSSANCHORSIDEWALK ANCHOR & GUY(P) FIBER & COUNTF48(P) .625 COAX(P) .875 COAXCOMCAST AERIAL SYMBOLSPROPOSEDEXISTINGWRECKOUTPOLE W/O RISERRISERARMVERTICAL GROUNDSLACK SPANOVERHEAD GUYTANGENT ATTACHMENTDEAD-ENDDOUBLE DEAD-END(E) FIBER & COUNTF48(E) .625 COAX(E) .875 COAXSLSLTSTSTSTSCCCTTTTWWTS?PUMPFWELLWTREE TRIMLIGHT/MEDIUM/HEAVYLMH//WRECKOUTVAULTSPLICE CASEMANHOLEPEDESTALPPPAMINIBRIDGERTTTAATAPAMPLIFER POTHOLEBORE PIT / EXCAVATIONMMMPROPOSEDEXISTINGWRECKOUTNODEABCDABCDABCDSTORAGE LOOPX'X'W?LIT INTERSECTIONFASFLASHING ARROWSEQUENTIAL ARROWSEQUENTIAL CHEVRONFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONORFLASHING DIAMOND CAUTIONARROWBOARD PLACEMENT (SEE BELOW)CHANNELIZING DEVICES / MIN DIMENSIONSNOTE(S):1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE, LEGIBILITYDISTANCE, NUMBER OF ELEMENTS AND OTHERSPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OF ARROWHEADEQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVE SOLIDRECTANGULAR APPEARANCES. A TYPE D ARROW BOARDSHALL CONFORM TO THE SHAPE OF THE ARROW.ARROWBOARD TYPE MIN LEGIBILITYDISTANCEMIN SIZE MINIMUM# OFELEMENTSABCD48"×24"60"×30"96"×48"NONE12 MILE1 MILE34 MILE12 MILE121315125FT MIN4FT MIN8-12"45°TYPE 3 BARRICADE3FT MIN45°2FT MIN8-12"TYPE 1 BARRICADE3FT MIN8-12"2FT MIN45°TYPE 2 BARRICADE3-4"6"2"4"28'-36" MAXSPEED < 45MPHNIGHT AND/OR FREEWAYMORE THAN 36"4-6" TYPCONECONESPEED ≥ 45MPHDIRECTION INDICATOR BARRICADE12"8"36" MIN 24" MIN45°UNLIT INTERSECTIONDBTRENCHAVAC-TSPOTTER STATIONALL TRAFFIC CONTROL DEVICES / ANNOTATIONS PER MUTCDASTS R/WFOCFOCFOCFOCFOCFOCFOCFOCR/WR/WR/WR/WR/WR/WR/WFLFLFLFLFLFLFLFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSW←D R I V E W A Y →←DRIVEWAY→58' 6' 42' 10'←DRIVEWAY→2614 CEDAR AVE S,RENTON, WA 98055, USA2620 CEDAR AVE S,RENTON, WA 98055, USA2626 CEDAR AVE S,RENTON, WA 98055, USA2625 BENSON RD S,RENTON, WA 98055, USA2702 CEDAR AVE S,RENTON, WA 98055, USA2705 108TH AVE SE,RENTON, WA 98055, USA2708 CEDAR AVE S,RENTON, WA 98055, USA16415 1 0 8TH AVE SE ,RENTON, WA 98055 , USA 2714 CEDAR AVE S,RENTON, WA 98055, USA16425 BENSON RD S ,RENTON, WA 98055 , USA16501 BENSON RD S,RENTON, WA 98055, USA16515 BENSON RD S ,RENTON, WA 98055 , USA1305 S 2 7 TH ST ,RENTON, WA 98055 , USA1307 S 2 7 TH ST ,RENTON, WA 98055 , USADBDBDB56'132'170'BENSON RD SR/WR/WR/WR/WR/WR/WR/W←DRIVEW A Y → ←DRIVEW A Y →AAAAAAAAAAAAAAAAAAAAAAA223'341'POLE 1POLE 2POLE 3POLE 4FLFLFLFLFLFL200'5' T2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2) 1211 S 26TH ST RENTON, WA 98055, USA JB824118REVISIONSDATEDESCRIPTIONINITIALSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:RRCOMCASTSEFNCOCOMMUNICATIONS03/03/227REVISIONSDATEDESCRIPTIONINITIAL5SITE PLAN-1SITE PLAN CONSTRUCTION NOTES1TIE IN TO EXISTING POLE.1NCONSTRUCTION NOTE:POT HOLE LOCATIONS TO BEVERIFIED WITH UTILITY LOCATES,UTILITY DEPTHS THEN TO BEVERIFIED FROM POT-HOLES, NODIGGING OR BORING TO BE DONEPRIOR TO LOCATING ALL UTILITIESRELATING TO PROJECT.BORE PATH WILL ADHERE TO A 12"MIN. VERTICAL SEPARATION FROMEXISTING UTILITIES AND A 5' MINHORIZONTAL SEPARATION FROMEXISTING UTILITIES.CONTRACTOR IS TO RESTORE ANYDAMAGE LANDSCAPE TO CURRENTCITY STANDARDS.ALL ADA RAMP/S WILL NOT BETOUCHED OR DAMAGED DURINGCONSTRUCTION.MATCH TO SITE PLAN - 2MATCH TO SITE PLAN - 3 45622666222EXISTING POLE (1-4).4RISER DOWN.5BORE AND PLACE 2(2")CONDUIT WITH 48CT FIBER.6OVERLASH 48CT FIBER TOEXISTING STRAND.33PLACE APPROPRIATE STORAGE. FOCFOC FOC FOCFOCFOCFOC FOCSWSWSWSWSWSW SW SWR/WR/W R/WR/WR/WR/W R/WR/W R/W R/WR/WR/WR/WR/WR/WSW SW SWSWSW SW SW SW FOC FOC FOCFOCFOCFOCFOCFOCFLFL FOCFOCFOCFOCFOCFOCSW SW SW SW SW SW SWR/W R/W ←DRIVEWAY →S 26TH STCEDAR AVE SBENSON RD SBENSON RD S17'33'10'57'15'32'10'1211 S 26TH ST,RENTON, WA 98055, USA60'1207 S 26TH ST,RENTON, WA 98055, USA2608 CEDAR AVE S,RENTON, WA 98055, USA2640 BENSON RD S ,RENTON, WA 98055 , USAPDBDBDBDBDBDBDBDBDBDB341'R/WR/WR/WR/WR/W66'12'34'20'78'17'48'13'←DRIVEWAY→9'2' T2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2) 1211 S 26TH ST RENTON, WA 98055, USA JB824118REVISIONSDATEDESCRIPTIONINITIALSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:RRCOMCASTSEFNCOCOMMUNICATIONS03/03/227REVISIONSDATEDESCRIPTIONINITIAL6SITE PLAN-24 N23MATCH TO SITE PLAN - 11SITE PLAN CONSTRUCTION NOTES1BORE AND PLACE 2(2")CONDUIT WITH 48CT FIBER.2EXISTING PEDESTAL.3PLACE NEW VAULT.5END OF ROW DESIGN.4UPGRADE NODE TO 2X4 RPHYAND SPLICE HERE.5CONSTRUCTION NOTE:POT HOLE LOCATIONS TO BEVERIFIED WITH UTILITY LOCATES,UTILITY DEPTHS THEN TO BEVERIFIED FROM POT-HOLES, NODIGGING OR BORING TO BE DONEPRIOR TO LOCATING ALL UTILITIESRELATING TO PROJECT.BORE PATH WILL ADHERE TO A 12"MIN. VERTICAL SEPARATION FROMEXISTING UTILITIES AND A 5' MINHORIZONTAL SEPARATION FROMEXISTING UTILITIES.CONTRACTOR IS TO RESTORE ANYDAMAGE LANDSCAPE TO CURRENTCITY STANDARDS.ALL ADA RAMP/S WILL NOT BETOUCHED OR DAMAGED DURINGCONSTRUCTION. FOCFOCFOCFOCFOCFOCFOCFOCFOCR/WR/WR/WR/WR/WFLFLFLFLFLFLFLFLFLFLFLFOC FOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWEOPR/WR/W R/W R/W R/WR/WR/WEOPR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/W←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY →←DRIVE W A Y →←DRIVEWAY→106TH AVE SESE 166TH ST16525 BENSON RD S,RENTON, WA 98055, USA16533 BENSON RD S,RENTON, WA 98055, USA16543 BENSON RD S,RENTON, WA 98055, USA16551 106TH AVE SE,RENTON, WA 98055, USA10502 SE 166TH ST ,RENTON, WA 98055 , USA 1 6 5 6 1 106TH AVE SE ,RENTON, WA 9 8 0 5 5 , USA16550 106TH AVE SE,RENTON, WA 98055, USA1 6 6 0 2 106TH AVE SE ,RENTON, WA 98055 , USA2824 108TH AVE SE,RENTON, WA 98055, USA15 0 3 S 28TH ST ,RENTON , WA 9 8055 , USA1431 S 28TH ST ,RENTON , WA 9 8 055 , USA14 1 3 S 28TH ST ,RENTON , WA 98055 , USA 2 724 BENSON RD S ,RENTON , WA 9 8 0 5 5 , USA1417 S 2 8TH ST ,RENTON, WA 98055 , USA1409 S 28TH ST,RENTON, WA 98055, USA223'157'162'176'BENSON RD S←DRIVEWAY →BENSON RD S←DRIVEWAY→←DRIVEWAY →45'10'25'10'R/W←DRIVEW AY →70'11'40'19'AAAAAAAAAAAAAAAAAAAAAAAAAAAS 28TH ST22'64'R/W POLE 6POLE 7POLE 8POLE 5←DRIVEWAY→ 62' 9'37'16'14'22'12'48'24'18'T2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2) 1211 S 26TH ST RENTON, WA 98055, USA JB824118REVISIONSDATEDESCRIPTIONINITIALSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:RRCOMCASTSEFNCOCOMMUNICATIONS03/03/227REVISIONSDATEDESCRIPTIONINITIAL7SITE PLAN-3 N4MATCH TO SITE PLAN - 11 1122221SITE PLAN CONSTRUCTION NOTES1OVERLASH 48CT FIBER TOEXISTING STRAND.2EXISTING POLE (5-8).3UPGRADE NODE TO 1X2 RPHYAND SPLICE HERE.4END OF ROW DESIGN.3 SEFNCO COMMUNICATIONS 4610 TACOMA AVE SUMNER WA, 98390 September 21, 2022 To whom it may concern: City of Renton 1055 South Grady Way Renton, WA 98057 RE: Aerial Variance Request for JB0000824118 To whom it may concern, SEFNCO Communications has been contracted to design and engineer this project on behalf of Comcast Cablevision. Comcast is applying for a variance request in order to upgrade their existing facilities. Comcast proposes to bore & place (2) 2” conduit w/ 48ct fiber ~341’, overlash 48ct fiber ~1076’ & place appropriate storage ~200’. Comcast is requesting that the City of Renton approve this variance request based on the fact that the requirements for undergrounding this proposed over-lash will not cause substantial adverse impacts to other person or entities in the immediate area and will cause undue hardship. 1. Installation of undergrounding facilities will increase the total cost of construction roughly 15-25 times the amount of an aerial over-lash on the existing Comcast strand. 2. Potential damage to underground facilities will be increased. 3. Over-lash will not cause substantial adverse impact to other persons or entities in the immediate area. Over-lashing the cable will be accomplished in a few days, and the residents will not notice any impact. Comcast will clean up the over-lashed spans as necessary and identify and remove any existing dead cables along this route. 4. The variance is necessary to prevent and undue hardship due to the increased construction costs if forced to install the proposed extension underground. 5. The granting of the variance will not be materially detrimental to the public welfare because Comcast does agree to underground the cable system, but they are waiving the obligation into the future when all other utilities are underground to prevent an undue hardship against Comcast currently. Upon the granting of the Variance, Comcast will coordinate construction and traffic control as per your requirements. Comcast and their contractors want to cooperate at the highest level and agree to adhere to all provisions and requirements set forth by the City of Renton to insure safe installation and maintenance of the proposed facilities. If you have any further questions regarding this project please contact Steve Harshfield at 253- 266- 4741. Thank you for your consideration in this matter. Carissa Morris Carissa Morris Lead Permit Coordinator SEFNCO Communications, Inc. o 253 313-2057 | e 30TUcarmorris@sefnco.comU30T Attachments: 1. Application for ROW permit 2. 11” x 17” Site plan 3. 11” x 17” Design plan 4. Traffic Control Plan September 27, 2022 Carissa Morris Sefnco Communication Inc. 4610 Tacoma Avenue, Sumner WA 98390 Via Email: carmorris@sefnco.com SUBJECT: Request for Undergrounding Exemption (JB#824118, MFP22002068, 1211 S 26th St) Dear Ms. Morris: The City of Renton has reviewed your request to grant Comcast an exemption from Renton Municipal Code (RMC) 4-6-090(C) which states that all new electrical or communication facilities shall be required to be installed underground, pursuant to the standards of the section of RMC. Comcast proposes to have Sefnco Communications Inc overlash new 48ct fiber for a total of approximately 1,417 lineal feet to existing Puget Sound Energy (PSE) poles along Benson Rd S and 106th Ave SE within the City. See the enclosed Site Plan showing the proposed overlashing limits. ANALYSIS: The City has considered the request for an exemption from RMC 4-6-090. Ordinance 5720 grants Comcast, the right to install fiber optic cable and related appurtenances under, along, over, below, through and across the streets, avenues and alleys of City of Renton within the right-of-way of Renton. Section 3.4 of the franchise ordinance states that if all of the distribution lines all the wireline service providers, such as telecommunications service providers, as defined in RCW 35.99.010, a utility service provider or a Cable Operator (collectively “Service Providers”) in any portion of the Franchise Area are underground, Grantee shall place its Cable System’s distribution cables underground within that area; provided that such underground locations are actually capable of accommodating Grantee’s cable and other equipment without technical degradation of the Cable Systems’ signal quality. The proposal would utilize existing poles with other attached franchisee communication facilities and overlash to the existing Comcast aerial path. As minimum vertical height clearance of 15’-6” would need to be provided for, any existing obsolete cable will need to be removed; staff recommends these as conditions of approval. Therefore, the City is granting an exemption with conditions, per the Comcast franchise agreement which allows new overhead facilities to be placed overhead provided there are other similar providers overhead as well. Comcast is required to obtain all necessary private utility easements for work on private property. DECISION: The requested exemption from underground utility installation requirements RMC4-6-090 (C) as requested by the applicant is approved with conditions subject to the conditions below as the request complies with the Comcast Franchise Agreement. Comcast Job JB#824118 Page 2 of 2 September 27, 2022 Conditions of Approval: 1. Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15’-6”. 2. Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. 3. A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 4. The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at the Applicant’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case the Applicant shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and Economic Development Administrator or designee, from the first event triggering the requirement to underground the aerial lines. This decision to approve the exemption with conditions is subject to a fourteen (14) day appeal period from the date of this letter per RMC 4-8-110. Any appeals of the administrative decision must be filed with the City Clerk, along with the required appeal fee, by 5:00 pm, October 11, 2022. Due to the ongoing state of emergency enacted by Governor’s Proclamation 20-28.14 (and as amended), the City Clerk’s Office is working remotely. For that reason, appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov or delivered to City Hall 1st floor Lobby Hub Monday through Friday. The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date if your appeal is submitted electronically. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov. Sincerely, Brianne Bannwarth, PE Development Engineering Director cc: C.E. “Chip” Vincent, CED Administrator Justin Johnson, Construction Engineering Manager Scott Warlick, Engineering Specialist III Holly Powers, Engineering Specialist III Franchise Permits Enclosures: Site Plan SEFNCOCOMMUNICATIONSPROPOSED AERIAL AND UNDERGROUND FIBER INSTALLATIONCOMCASTT2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2)1211 S 26TH ST, RENTON, WA 98055, USAJB# 824118MFP22002068 DBDBDBAAAAAAAAAAASHEET INDEXPG #DESCRIPTION OF WORKTOTALCONTACTST2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2) 1211 S 26TH ST RENTON, WA 98055, USA JB824118REVISIONSDATEDESCRIPTIONINITIALSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:RRCOMCASTSEFNCOCOMMUNICATIONS03/03/22VICINITY MAP72VICINITY MAPPERMITTINGASHLEY KIEHN4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 999-2271EMAIL: ASKIEHN.SEFNCO.COMSEFNCO CONSTRUCTION MANAGERCOMCASTSEFNCO OPEBRANDON MORRIS410 TACOMA AVESUMNER, WA 98390PHONE:253-306-1908EMAIL: BRANDONMORRIS@SEFNCO.COMBARBARA MARTIN410 VALLEY AVEPUYALLUP, WA 98371PHONE: (253) 864-4246EMAIL: BARBARA_MARTIN2@COMCAST.COMENDSTA. A 03+411211 S 26TH ST,RENTON, WA 98055ENDSTA. B 10+7616602 106TH AVE SE,RENTON, WA 98055NTSN1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5-7SITE-PLANSTEVE HARSHFIELD4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 266-4741EMAIL: STHARSHFIELD@SEFNCO.COMBEGINSTA. A 00+002705 108TH AVE SE,RENTON, WA 98055STA. B 00+00BORE AND PLACE 2(2") CONDUIT WITH 48CT FIBER341LFOVERLASH 48CT FIBER1076LFPLACE APPROPRIATE STORAGE200LFPLACE NEW VAULTTOTAL:1617LFMFP22002068 T2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2) 1211 S 26TH ST RENTON, WA 98055, USA JB824118REVISIONSDATEDESCRIPTIONINITIALSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:RRCOMCASTSEFNCOCOMMUNICATIONS03/03/227REVISIONSDATEDESCRIPTIONINITIAL3GENERAL NOTES NTSGENERAL NOTESTHE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBYDISCLAIMS ANY RESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION.PERSONS WORKING IN THE AREA COVERED BY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THE LOCATION OF UNDERGROUND UTILITIES PRIOR TOPERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OREXCEED SITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THELOCAL JURISDICTION REGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERETHERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLESTANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OREASEMENTS MAY REQUIRE INSPECTED AND APPROVED BY THE LOCAL JURISDICTION INSPECTOR.INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BE PROVIDED BY DESIGNEE OFPROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OFEXISTING UTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITYCOMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION ISNOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THELOCAL UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUESTEXACT FIELD LOCATIONS OF EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENTLOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTS AND AT POTENTIALUTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALLEXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALLAPPLICABLE AGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTORAT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTH DISTURBING ACTIVITY ORCONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALLUTILITY COMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIESDURING CONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION,AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FORCONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OFTHE APPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS ANDEXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOTLIMITED TO: EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THECONTRACTOR, HIS SUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE ASITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALLCONTACT THE ENGINEER IMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OFSAID STANDARD, UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THECONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITHM.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THERIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFICCONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION APRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCAL JURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FORTHE COMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS ORDESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESSSPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYSFREE AND CLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OFRECORD DRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCALJURISDICTION INSPECTOR AT ALL TIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FORADDITIONAL INFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THERECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BEMAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBEDAREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCALJURISDICTION ENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTUREOR RUNNING OF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANYOTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVEDBY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TODIGGING.18.ALL NEW ANCHORS WILL BE 1" X 7' MANTA RAY ANCHORS.19.ALL NEW ANCHORS WILL BE PLACED WITH A MINIMUM LEAD LENGTH EQUAL TO OR GREATER THANA 3 TO 1 RATIO.20.NO CROSS DRILLING WITHIN 3" OF EXISTING HOLES.21.ALL NEW ATTACHMENTS SHALL BOND TO MGN WHERE REQUIRED.·HOAHEIGHT OF ATTACHMENT·FGAFIBER GLASS ARM·WAWOOD ARM·AAALLEY ARM·MAMETAL (SEATTLE) ARM·CACOMPOSITE (PUPI) ARM·TOPTOP OUTSIDE POSITION·TIPTOP INSIDE POSITION·BOPBOTTOM OUTSIDE POSITION·BIPBOTTOM INSIDE POSITION·FSFIELD SIDE·RSROAD SIDE·DEDEAD END ATTACHMENT·FDEFALSE DEAD END ATTACHMENT·OHGOVERHEAD GUY·IMINTEGRATED MESSENGER·SLMASTREET LIGHT MAST ARM·DLDRIP LOOP·(E)EXISTING·(P)PROPOSEDABBREVIATIONSTRAFFIC CONTROL GENERAL NOTES1.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2.SIDEWALK ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 5' PATHCANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACEOF CURB. (PEDESTRIAN PATH PROVIDED WHERE REQUIRED) AND WILL BE MONITORED BY ASPOTTER TO ENSURE FLOW AND SAFETY DURING WORK UNLESS OTHERWISE NOTED. ASPOTTER SHALL NOT DIRECT TRAFFIC.3.NO EXCEPTION TAKEN- CONTRACTOR IS RESPONSIBLE FOR ADA COMPLIANCE.4.ALL CONTROL SET-UP, SIGN SPACING AND PROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROL DEVICES (M.U.T.C.D).5.CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSO ADOPTED SPECIALIZED GUIDELINESFOR TRAFFIC CONTROL WITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OF THEON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF AND ANY SPECIAL CONDITIONS EXIST.6.FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302.7.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THAT LANE SHALL BE A MINIMUM OF 11' WIDE,UNLESS SPOTTER/FLAGGERS ARE USED, IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'.8.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT, EMPLOYEES AND CHILDREN. WHILEPASSENGER LOADING/UNLOADING, STOPPED OR SLOWING: CEASE WORK, YIELD. WHENSCHOOL TRANSIT, AND/OR PEDESTRIANS, DEPART COMMENCE WORK.MFP22002068 T2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2) 1211 S 26TH ST RENTON, WA 98055, USA JB824118REVISIONSDATEDESCRIPTIONINITIALSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:RRCOMCASTSEFNCOCOMMUNICATIONS03/03/2274LEGEND NTSLEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERPOWERPARCEL LINERIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILSDSDWWSSSSGGTTLIPD/LEOPFOCRWRWBUILDING OUTLINEPFLFOG LINESIDEWALKSWSWTRENCHDIRECT BOREPROPOSED AERIAL STRAND PROOF/PULLPROPOSED OVERLASHMINOR ARTERIALCOLLECTOR ARTERIALINTERSTATE FREEWAYACCESS STREETPRINCIPAL ARTERIALBUILDINGR/WWARNING SIGN PLACEMENT (W/ PART #)TRAFFIC BARRELHYDRO-VAC TRENCHKEEPRIGHTREGULATORY SIGN (W/ PART #)LIMITSPEEDR2-125SPEED LIMIT CALLOUTSIGN PLACEMENT / DIRECTIONTRAFFIC CONEFLAGGER STATIONFLAGGER STATIONPATROL CARUNIFORMED POLICE OFFICERWORK VEHICLEFENCESTREET LIGHT HANDHOLETELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALSTREET LIGHT POLETRAFFIC SIGNAL HANDHOLECATV MANHOLECATV HANDHOLECATV PEDESTALTRAFFIC SIGNAL POLESTORM MANHOLEWATER VALVEWATER METERWATER MANHOLETELECOM PEDESTALSTORM INLETSTORM DISCHARGE POINTSTORM DRAIN UNKNOWN WATER UNKNOWNWATER VAULTWATER RESERVOIRD?SISEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?STORM DRAIN VAULT SDSEWER CLEANOUTSEWER MANHOLESCSEWER CATCH BASIN SSSTORM ACCESS POINTBASE LAYERSEXISTING UTILITIESROAD HATCH CLASSIFICATIONROW WORK LINETYPECOMCAST UNDERGROUND SYMBOLSEXISTING UTILITY SYMBOLSTRAFFIC CONTROL SYMBOLSSTORM CATCH BASIN SDTRAFFIC SIGNAL VAULTGAS METERTEST VALVEPEDESTAL UNK UTILITYFIRE HYDRANTGAS VALVEGAS TEST POINTGAS MANHOLEWATER PUMPGGGWATER AIR CONTROL VALVEWATER WELLWATER SAMPLING STATIONPOWER HANDHOLEPOWER MANHOLEPOWER CABINETPOWER VAULTPOWER PEDESTALPPOWER UNKNOWN PPPPPP?SIGN POSTCULVERTTRANSIT STOPDRIVEWAY (FOC OR EOP)SDSSANCHORSIDEWALK ANCHOR & GUY(P) FIBER & COUNTF48(P) .625 COAX(P) .875 COAXCOMCAST AERIAL SYMBOLSPROPOSEDEXISTINGWRECKOUTPOLE W/O RISERRISERARMVERTICAL GROUNDSLACK SPANOVERHEAD GUYTANGENT ATTACHMENTDEAD-ENDDOUBLE DEAD-END(E) FIBER & COUNTF48(E) .625 COAX(E) .875 COAXSLSLTSTSTSTSCCCTTTTWWTS?PUMPFWELLWTREE TRIMLIGHT/MEDIUM/HEAVYLMH//WRECKOUTVAULTSPLICE CASEMANHOLEPEDESTALPPPAMINIBRIDGERTTTAATAPAMPLIFER POTHOLEBORE PIT / EXCAVATIONMMMPROPOSEDEXISTINGWRECKOUTNODEABCDABCDABCDSTORAGE LOOPX'X'W?LIT INTERSECTIONFASFLASHING ARROWSEQUENTIAL ARROWSEQUENTIAL CHEVRONFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONORFLASHING DIAMOND CAUTIONARROWBOARD PLACEMENT (SEE BELOW)CHANNELIZING DEVICES / MIN DIMENSIONSNOTE(S):1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE, LEGIBILITYDISTANCE, NUMBER OF ELEMENTS AND OTHERSPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OF ARROWHEADEQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVE SOLIDRECTANGULAR APPEARANCES. A TYPE D ARROW BOARDSHALL CONFORM TO THE SHAPE OF THE ARROW.ARROWBOARD TYPE MIN LEGIBILITYDISTANCEMIN SIZE MINIMUM# OFELEMENTSABCD48"×24"60"×30"96"×48"NONE12 MILE1 MILE34 MILE12 MILE121315125FT MIN4FT MIN8-12"45°TYPE 3 BARRICADE3FT MIN45°2FT MIN8-12"TYPE 1 BARRICADE3FT MIN8-12"2FT MIN45°TYPE 2 BARRICADE3-4"6"2"4"28'-36" MAXSPEED < 45MPHNIGHT AND/OR FREEWAYMORE THAN 36"4-6" TYPCONECONESPEED ≥ 45MPHDIRECTION INDICATOR BARRICADE12"8"36" MIN 24" MIN45°UNLIT INTERSECTIONDBTRENCHAVAC-TSPOTTER STATIONALL TRAFFIC CONTROL DEVICES / ANNOTATIONS PER MUTCDASTSMFP22002068 R/WFOCFOCFOCFOCFOCFOCFOCFOCR/WR/WR/WR/WR/WR/WR/WFLFLFLFLFLFLFLFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSW←D R I V E W A Y →←DRIVEWAY→58' 6' 42' 10'←DRIVEWAY→2614 CEDAR AVE S,RENTON, WA 98055, USA2620 CEDAR AVE S,RENTON, WA 98055, USA2626 CEDAR AVE S,RENTON, WA 98055, USA2625 BENSON RD S,RENTON, WA 98055, USA2702 CEDAR AVE S,RENTON, WA 98055, USA2705 108TH AVE SE,RENTON, WA 98055, USA2708 CEDAR AVE S,RENTON, WA 98055, USA16415 1 0 8TH AVE SE ,RENTON, WA 98055 , USA 2714 CEDAR AVE S,RENTON, WA 98055, USA16425 BENSON RD S ,RENTON, WA 98055 , USA16501 BENSON RD S,RENTON, WA 98055, USA16515 BENSON RD S ,RENTON, WA 98055 , USA1305 S 2 7 TH ST ,RENTON, WA 98055 , USA1307 S 2 7 TH ST ,RENTON, WA 98055 , USADBDBDB56'132'170'BENSON RD SR/WR/WR/WR/WR/WR/WR/W←DRIVEW A Y → ←DRIVEW A Y →AAAAAAAAAAAAAAAAAAAAAAA223'341'POLE 1POLE 2POLE 3POLE 4FLFLFLFLFLFL200'5' T2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2) 1211 S 26TH ST RENTON, WA 98055, USA JB824118REVISIONSDATEDESCRIPTIONINITIALSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:RRCOMCASTSEFNCOCOMMUNICATIONS03/03/227REVISIONSDATEDESCRIPTIONINITIAL5SITE PLAN-1SITE PLAN CONSTRUCTION NOTES1TIE IN TO EXISTING POLE.1NCONSTRUCTION NOTE:POT HOLE LOCATIONS TO BEVERIFIED WITH UTILITY LOCATES,UTILITY DEPTHS THEN TO BEVERIFIED FROM POT-HOLES, NODIGGING OR BORING TO BE DONEPRIOR TO LOCATING ALL UTILITIESRELATING TO PROJECT.BORE PATH WILL ADHERE TO A 12"MIN. VERTICAL SEPARATION FROMEXISTING UTILITIES AND A 5' MINHORIZONTAL SEPARATION FROMEXISTING UTILITIES.CONTRACTOR IS TO RESTORE ANYDAMAGE LANDSCAPE TO CURRENTCITY STANDARDS.ALL ADA RAMP/S WILL NOT BETOUCHED OR DAMAGED DURINGCONSTRUCTION.MATCH TO SITE PLAN - 2MATCH TO SITE PLAN - 3 45622666222EXISTING POLE (1-4).4RISER DOWN.5BORE AND PLACE 2(2")CONDUIT WITH 48CT FIBER.6OVERLASH 48CT FIBER TOEXISTING STRAND.33PLACE APPROPRIATE STORAGE.MFP22002068 FOCFOC FOC FOCFOCFOCFOC FOCSWSWSWSWSWSW SW SWR/WR/W R/WR/WR/WR/W R/WR/W R/W R/WR/WR/WR/WR/WR/WSW SW SWSWSW SW SW SW FOC FOC FOCFOCFOCFOCFOCFOCFLFL FOCFOCFOCFOCFOCFOCSW SW SW SW SW SW SWR/W R/W ←DRIVEWAY →S 26TH STCEDAR AVE SBENSON RD SBENSON RD S17'33'10'57'15'32'10'1211 S 26TH ST,RENTON, WA 98055, USA60'1207 S 26TH ST,RENTON, WA 98055, USA2608 CEDAR AVE S,RENTON, WA 98055, USA2640 BENSON RD S ,RENTON, WA 98055 , USAPDBDBDBDBDBDBDBDBDBDB341'R/WR/WR/WR/WR/W66'12'34'20'78'17'48'13'←DRIVEWAY→9'2' T2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2) 1211 S 26TH ST RENTON, WA 98055, USA JB824118REVISIONSDATEDESCRIPTIONINITIALSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:RRCOMCASTSEFNCOCOMMUNICATIONS03/03/227REVISIONSDATEDESCRIPTIONINITIAL6SITE PLAN-24 N23MATCH TO SITE PLAN - 11SITE PLAN CONSTRUCTION NOTES1BORE AND PLACE 2(2")CONDUIT WITH 48CT FIBER.2EXISTING PEDESTAL.3PLACE NEW VAULT.5END OF ROW DESIGN.4UPGRADE NODE TO 2X4 RPHYAND SPLICE HERE.5CONSTRUCTION NOTE:POT HOLE LOCATIONS TO BEVERIFIED WITH UTILITY LOCATES,UTILITY DEPTHS THEN TO BEVERIFIED FROM POT-HOLES, NODIGGING OR BORING TO BE DONEPRIOR TO LOCATING ALL UTILITIESRELATING TO PROJECT.BORE PATH WILL ADHERE TO A 12"MIN. VERTICAL SEPARATION FROMEXISTING UTILITIES AND A 5' MINHORIZONTAL SEPARATION FROMEXISTING UTILITIES.CONTRACTOR IS TO RESTORE ANYDAMAGE LANDSCAPE TO CURRENTCITY STANDARDS.ALL ADA RAMP/S WILL NOT BETOUCHED OR DAMAGED DURINGCONSTRUCTION.MFP22002068 FOCFOCFOCFOCFOCFOCFOCFOCFOCR/WR/WR/WR/WR/WFLFLFLFLFLFLFLFLFLFLFLFOC FOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWEOPR/WR/W R/W R/W R/WR/WR/WEOPR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/W←DRIVEWAY→←DRIVEWAY→←DRIVEWAY→←DRIVEWAY →←DRIVE W A Y →←DRIVEWAY→106TH AVE SESE 166TH ST16525 BENSON RD S,RENTON, WA 98055, USA16533 BENSON RD S,RENTON, WA 98055, USA16543 BENSON RD S,RENTON, WA 98055, USA16551 106TH AVE SE,RENTON, WA 98055, USA10502 SE 166TH ST ,RENTON, WA 98055 , USA 1 6 5 6 1 106TH AVE SE ,RENTON, WA 9 8 0 5 5 , USA16550 106TH AVE SE,RENTON, WA 98055, USA1 6 6 0 2 106TH AVE SE ,RENTON, WA 98055 , USA2824 108TH AVE SE,RENTON, WA 98055, USA15 0 3 S 28TH ST ,RENTON , WA 9 8055 , USA1431 S 28TH ST ,RENTON , WA 9 8 055 , USA14 1 3 S 28TH ST ,RENTON , WA 98055 , USA 2 724 BENSON RD S ,RENTON , WA 9 8 0 5 5 , USA1417 S 2 8TH ST ,RENTON, WA 98055 , USA1409 S 28TH ST,RENTON, WA 98055, USA223'157'162'176'BENSON RD S←DRIVEWAY →BENSON RD S←DRIVEWAY→←DRIVEWAY →45'10'25'10'R/W←DRIVEW AY →70'11'40'19'AAAAAAAAAAAAAAAAAAAAAAAAAAAS 28TH ST22'64'R/W POLE 6POLE 7POLE 8POLE 5←DRIVEWAY→ 62' 9'37'16'14'22'12'48'24'18'T2B/D - WAKVD02B00 1x2 - WAKVD02A00 2x4 (RN21A 2x2) 1211 S 26TH ST RENTON, WA 98055, USA JB824118REVISIONSDATEDESCRIPTIONINITIALSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:RRCOMCASTSEFNCOCOMMUNICATIONS03/03/227REVISIONSDATEDESCRIPTIONINITIAL7SITE PLAN-3 N4MATCH TO SITE PLAN - 11 1122221SITE PLAN CONSTRUCTION NOTES1OVERLASH 48CT FIBER TOEXISTING STRAND.2EXISTING POLE (5-8).3UPGRADE NODE TO 1X2 RPHYAND SPLICE HERE.4END OF ROW DESIGN.3MFP22002068 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Conditions for Permit MFP22002068 Engineering 1 Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15'-6". 2 Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. 3 The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at the Applicant’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case the Applicant shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and Economic Development Administrator or designee, from the first event triggering the requirement to underground the aerial lines. 4 A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. Page 1 of 1